Categories ; Posterior, Flapless, Astra Tech
Copyright Š 2011 Idondivi, Inc. All rights reserved.
Non restorable lower first molar, extracted, healed site at 3 Months
Copyright Š 2011 Idondivi, Inc. All rights reserved
2
Healed site # 19
Copyright Š 2011 Idondivi, Inc. All rights reserved
3
Purposely over extended impression captures 14 mm of the alveolar ridge
Copyright Š 2011 Idondivi, Inc. All rights reserved
4
Bone sounding measurements topical anesthetic and small needle with rubberstop.
Copyright Š 2011 Idondivi, Inc. All rights reserved
5
Denture tooth, the “fastest wax –up in the west”, and reusable over and over again.
Copyright © 2011 Idondivi, Inc. All rights reserved
6
Vacuform of denture tooth
Copyright Š 2011 Idondivi, Inc. All rights reserved
7
BLP related to screw access hole in the central fossa.
Copyright Š 2011 Idondivi, Inc. All rights reserved
8
Wings attached to vacuform carrier. Note that position of BLP is just a starting point, the wings are positioned independently, while the BLP is locking in the Bucco-Lingual and the platform position of the implant.
Copyright Š 2011 Idondivi, Inc. All rights reserved
9
Radiograph is diagnostic since the RIR’s overlap. The trajectory needs correction though.
Copyright Š 2011 Idondivi, Inc. All rights reserved
10
A 7 degree ( red) rotation block is selected. A metal drill guide is placed, and the trajectory is verified.
Copyright Š 2011 Idondivi, Inc. All rights reserved
11
Adequate attached tissue allows tissue punch.
Copyright Š 2011 Idondivi, Inc. All rights reserved
12
Nobel Biocare starting drill is used ( not to full depth) , although an Astra Tech implant will be placed. The starting drill removes the tissue plug, and flattens the ridge.
Copyright Š 2011 Idondivi, Inc. All rights reserved
13
Facilitate 2.0 drill with build in stop. Tip to stop 18.7 mm , listed as 18 mm.
Copyright Š 2011 Idondivi, Inc. All rights reserved
14
Osteotomy preparation for 8 mm implant
Copyright Š 2011 Idondivi, Inc. All rights reserved
15
Verification of initial twist drill preparation
Copyright Š 2011 Idondivi, Inc. All rights reserved
16
3.2 mm Facilitate drill
Copyright Š 2011 Idondivi, Inc. All rights reserved
17
3.7 Facilitate drill per Astra Tech drilling protocol.
Copyright Š 2011 Idondivi, Inc. All rights reserved
18
Astra Tech OsseoSpeed TX 4.0 S - 8 mm
Copyright Š 2011 Idondivi, Inc. All rights reserved
19
Visual guidance of implant placement. The guided carrier from Astra does not fit the hole diameter of the 3DCG. Hence the use of the regular Astra implant carrier
Copyright Š 2011 Idondivi, Inc. All rights reserved
20
Implant placed to full depth. Bottom of osteotomy is the depth control.
Copyright Š 2011 Idondivi, Inc. All rights reserved
21
Implant placed as planned
Copyright Š 2011 Idondivi, Inc. All rights reserved
22
Implant placed as planned
Copyright Š 2011 Idondivi, Inc. All rights reserved
23