Immediate implant placement

Page 1

Categories ; Immediate placement , Nobel Biocare, grafting, flapless, prototype

Copyright Š 2011 Idondivi, Inc. All rights reserved.


Fracture of lingual cusp. Patient in pain, just before the weekend. Total treatment time from diagnosis to implant and natural tooth pontic : 90 minutes

Copyright Š 2011 Idondivi, Inc. All rights reserved

2


Note lingual cusp missing, ideal implant axis assuming buccal resorption after extraction.

Copyright Š 2011 Idondivi, Inc. All rights reserved

3


Prototype BLP ( Bucco lingual positioner)

Copyright Š 2011 Idondivi, Inc. All rights reserved

4


Correct mesio distal position, Regular diameter.

Copyright Š 2011 Idondivi, Inc. All rights reserved

5


Estimation of the trajectory of the implant. Tungsten Ink prototype. Actual parts are radio opaque.

Copyright Š 2011 Idondivi, Inc. All rights reserved

6


Crossbar removed, exposing the retention rails

Copyright Š 2011 Idondivi, Inc. All rights reserved

7


Incorrect X-ray direction, double RIR’s visible .

Copyright © 2011 Idondivi, Inc. All rights reserved

8


Correct X-ray direction, RIR’S overlap. A 3 degree rotation block is indicated, so we’ll have some fresh bone on the mesial aspect of the implant. A 7 degree rotation-block would follow the root space and potentially have less initial stability Copyright © 2011 Idondivi, Inc. All rights reserved

9


Epithelium removed from sulcus with diamond bur

Copyright Š 2011 Idondivi, Inc. All rights reserved

10


2 mm drill diameter at 10 mm length . Color of the Flexistop has since changed to red for 3 mm

Copyright Š 2011 Idondivi, Inc. All rights reserved

11


Drilled to 10 mm length

Copyright Š 2011 Idondivi, Inc. All rights reserved

12


10 mm length

Copyright Š 2011 Idondivi, Inc. All rights reserved

13


2.8 mm drill diameter at 10 mm length

Copyright Š 2011 Idondivi, Inc. All rights reserved

14


3.25 mm drill diameter at 7 mm length. The implant is a tapered implant requiring a step back preparation

Copyright Š 2011 Idondivi, Inc. All rights reserved

15


Tap for Nobel Active Implant

Copyright Š 2011 Idondivi, Inc. All rights reserved

16


Grafting the socket

Copyright Š 2011 Idondivi, Inc. All rights reserved

17


Guided implant delivery.

Copyright Š 2011 Idondivi, Inc. All rights reserved

18


Prosthetically driven implant placement

Copyright Š 2011 Idondivi, Inc. All rights reserved

19


Additional grafting and socket seal with collaplug and cyano-acrylate tissue glue

Copyright Š 2011 Idondivi, Inc. All rights reserved

20


Natural tooth pontic

Copyright Š 2011 Idondivi, Inc. All rights reserved

21


Implant placement, good initial stability. Implant did not follow socket precisly as planned

Copyright Š 2011 Idondivi, Inc. All rights reserved

22


Healing within normal limits, with appropriate ISQ reading at 3 Months

Copyright Š 2011 Idondivi, Inc. All rights reserved

23


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.