Cross section of LiveDijk levee Positioning of sensor instruments in one of four measurement lines (measures in meters) Note: This document is based on a drawing without the exact positioning of the Borkumkade (road).
GeoBeads waterdepth and temperature sensor module (A)
GeoBeads multi-sensor modules (waterpressure, temperature, inclination) Left: (B) Right: (C)
Koperslakblokken 0,25 meter dik
Fibre optic cable GTC (temperature) (D)
GeoBeads wave sensor and cable cover on top of levee (K) or (L)
GeoBeads multi-sensor modules (waterpressure, temperature, inclination) Left: (E1...E4) Right: (G1...G2)
Inclinometer casing with GeoBeads inclinometer (F1...F5)
GeoBeads multi-sensor module installed in the air (air pressure, temperature, humidity) (J)
1,98
12,61
1,03
N.A.P + 10.
B
1,50
1,50
5,00
4,00
E2 4,00
N.A.P. N.A.P. - 2
Borkumkade (road)
G1
5,50
A
E1
14,00
N.A.P. + 2
1,50
C
6,60
K/L
8,54
J
1 :4
1,50
N.A.P. + 4
0
0,20
D
10,03
N.A.P. + 6
14,8 4
1 :3
8,95
N.A.P. + 8
6,3
F5
1:10 E3
1,95
4,00
N.A.P. - 4
G2
N.A.P. - 6
E4
N.A.P. - 8 8,15
16,35
3,60
13,05
20,70 2,00
9,80
9,70
8,10
20,20 31,97