Medentika 2016 mps catalog uk en

Page 1

» Passion

for Precision «

MPS

Multi Platform Systems

CATALOGUE 2016.1


» Content «

Medentika. A global leader at your service.

6 Introduction 14

B-Series

compatible with

Bredent Medical®/SKY®

24

BS-Series

compatible with

BEGO Implant Systems®/Semados® S, RS-RX, RI-Line

30

C-Series

compatible with

Altatec®/Camlog®

42

CX-Series

compatible with

Medentis Medical®/ICX®

48

D-Series

compatible with

Altatec®/Conelog®

60

E-Series

compatible with

Nobel Biocare®/NobelReplace Tapered®

78

EV-Series

compatible with

Dentsply®Implants/ASTRA TECH OsseoSpeed® EV

84 F-Series

compatible with

Nobel Biocare®/NobelActive®, NobelReplace Conical®

102 H-Series

compatible with

BIOMET 3i®/Certain®

118 I-Series

compatible with

BIOMET 3i®/External Hex®

132 K-Series

compatible with

Nobel Biocare®/Brånemark®

146 L-Series

compatible with

Straumann®/Bone Level®

164 N-Series

compatible with

Straumann®/Tissue Level®

182 R-Series

compatible with

Zimmer Dental®/Tapered Screw-Vent®

Medentika is there for you. We are grateful to our customers that have made us what we are, a leader in high precision, compatible, stock and custom-made abutments and components and the preferred partner for small and local and leading global laboratories and dental corporations.

we thank you for your trust

MIS®/SEVEN® Internal Hex

BioHorizons®/Tapered Internal, Tapered Internal Plus,

Tapered Tissue Level

202 S-Series

compatible with

DENTSPLY Implants®/ASTRA TECH OsseoSpeed® TX

220 T-Series

compatible with

DENTSPLY Implants®/XIVE® S

240 Y-Series

compatible with

DENTSPLY Implants®/ANKYLOS®

248 Novaloc Optiloc

252

Tools


4

5

Coming soon. Our new e-shop ...

Our Team. We always look forward to hearing from you.

» Coming soon «

Technical Support CAD/CAM Support Order acceptance

Instradent UK

We are there for you: Our Sales Team

Anita Mann

Office: +44 (0) 1293 560777 Email: customerservice.uk@instradent.com

Medentika Territory Manager – South Mobile: + 44 (0) 7540 772635 Email: anita.mann@instradent.com

Jason Hollinshead Medentika Territory Manager – North Mobile: +44 (0) 7540 772641 Email: jason.hollinshead@instradent.com


» Welcome

6

to Medentika «

Anyone who meets Medentika personnel will get to know a team. A team that since the foundation of the company collectively contributes knowledge and experience. A team that perfects products with élan. On a daily basis and with passion.

Medentika has character. And it is this character that gives us a morally sound base. In a world that is becoming more and more focused on the laws that drive market forces, we feel that this position is not only right, but important. What characterises Medentika is also our belief in the power of our ideas and in the innovative power of our products. We are Medentika – and if the Medentika label is on the packet, there is more than just an implant component inside, but an implant component that bears the knowledge and the experience that we have been putting into our products since Medentika was founded. We offer our customers our enthusiasm – a feature we use to perfect our products on a daily basis.

We take this task seriously, but we also embrace it with passion. And the result is an original product manufactured with the highest interface precision from an extremely wide range of prosthetics. This catalogue reflects our attitude in every single product. Our prosthetic components offer you new ways and even more treatment opportunities providing your patients more comfort and functionality! Sincerely your Jürgen Kälber » Bernd Gaddum » Frank Fix an the entire Medentika team.

7


8

9

You always have the choice: Do you enter one-sided, expensive business relationships with partners out of a sense of duty in whose system you are bound inflexibly and at high risk? Regardless of price, quality or environmental criteria? Or are you ready for an alternative, which is constantly compatible, extremely precise and also of interest economically. We begin with an open word: With all of our strategies, undertakings and developments we have had no greater a concern than your freedom! Freedom is a big word – and in scientific reality it means nothing more than your freedom of choice with a transparent price policy. This is exactly what we are providing for you.

We manufacture high-quality implants and also components and abutments in-house, which are compatible with all conventional implant systems. We do this not only at the highest technical level but also with a sense of fairness. We would like to ensure that things last. With this we mean not only our precision components but also our mutual business relationships, your economic freedom and ultimately of course also the health and wellbeing of the patient. The most important thing for us is primarily fair cooperation. This is how we think since the foundation of Medentika. This is also how we will form partnerships in the future: on equal terms, openly and completely transparent.


» Passion for

10

Precision «

» Precision, innovation,

and Compatibility for all major implant systems «

Our products are manufactured with precision and without compromise. They fulfill our customers’ highest requirements of quality, compatibility and durability.

As this quality results in extremely low complaint rates we can provide wide-ranging warranty conditions. Medentika not only assumes responsibility for the quality and durability of abutments manufactured and supplied by Medentika for 30 years, but also provides a limited warranty on other manufacturers’ implants used with the abutment. This extension of the limited warranty primarily takes effect if other manufacturers limit the war-

ranty of their implant because it has been combined with an abutment from Medentika. Components from Medentika will help provide a sound foundation for your restorations. In addition, our highly trained employees are available to dentists and dental technicians globally and free of charge – for all matters relating to Medentika but most especially in the case of technical complications.

11


12

13

Our products are created by innovative strength. And by creative development, detailed expert knowledge and exact marketing skills. And they are made in Germany.

FINITE ELEMENT ANALYSIS ACCORDING TO DIN EN ISO 14801

MECHANICAL PERMANENT LOAD TEST AT 5 MILLION LOAD CYCLES WITH 250 NEWTONS

Our quality management is consequently DIN EN ISO 13485 certified. And our quality assurance complies with the EU Directive 93/42/EEC. We meet the highest standards and maintain the norms. In addition, our products are uncompromisingly precisely manufactured. They take into account all the requirements of our customers in terms of quality, compatibility and durability. Medentika exclusively uses cold formed grade 5 titanium (Grade 5 cold formed) which has significantly higher tensile strength compared to normal grade 5 titanium. The quality and reliability of Medentika abutments was not just confirmed by our customers in the past 10 years but was also tested and confirmed by the following independent institutes:

by:

by:

UNIKE Design & Development GmbH in Trier

Professor for Mechanical Engineering Professor, Department of Endodontics, Prosthodontics and operative Dentistry Dental School Dr. Dwayne D. Arola University of Maryland of Baltimore County 1000 Hilltop Circle Baltimore (USA)


The B-Series abutments are compatible with

» B-SERIES «

Bredent Medical® SKY®

DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments.

Type 1 angled over flat

Typ 2 abgewinkelt über Nocke

Products indicated with ® are registered brand names of respective manufactures.


16

» B-Series «

» B-Series «

Bredent Medical® SKY®

Laboratory implant • Stainless

Bredent Medical® SKY®

17

Titanium base Zirconium abutment 2nd Generation

steel

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection Article Number

D 3,5-5,5 B 50

Laboratory implant CADCAM • Stainless

steel

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,5-5,5 3.5

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,5-5,5 5.5

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,5-5,5 3.5

0,3 B 1000 B 60 B 60 L

Titanium base Zirconium abutment 2nd Generation Implant connection Article Number Please note: This is used for 3D printmodels with Scanbody 2. generation.

D 3,5-5,5 B 80

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Placement instrument laboratory implant CADCAM • Stainless

steel

Implant connection Article Number

D 3,5-5,5 B 80 T

Titanium base Bridges/ bars 2nd Generation

Abutment screw • Titanium • Torx®

T6

• rotating

grade 5 KV

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Article Number

B 60

Laboratory screw • red

0,3 B 1100 B 60 B 60 L

coated

Article Number

B 60 L

0,3 B 1500 B 60 B 60 L


18

» B-Series «

» B-Series «

Bredent Medical® SKY®

PreFace® abutment

MedentiCAD abutment

• Titanium

• CrCo

Bredent Medical® SKY®

19

alloy / CTE 14.1 abutment screw • Recommended torque: 25 Ncm

grade 5 KV abutment screw • Recommended torque: 25 Ncm

• incl.

• incl.

Implant connection Diameter (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,5-5,5 11.5 B 9000-R B 60 B 60 L

D 3,5-5,5 16.0 B 9000-16R B 60 B 60 L

Implant connection Article Number Abutment screw Laboratory screw Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 3,5-5,5 B 900004 B 60 B 60 L

Implant connection Article Number Please note: For use on the model only!

D 3,5-5,5 B 9100

MedentiCAD wax-up base

PreFace® abutment

• Steel • incl.

• CrCo

alloy / CTE 14.1 • incl. abutment screw • Recommended torque: 25 Ncm

Implant connection Diameter (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,5-5,5 16.0 B 9800-16R B 60 B 60 L

abutment screw

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 25 Ncm

• Recommended

Scanbody 2 Generation nd

• Titanium

grade 5 KV coated • incl. retention screw • specially

Implant connection Gingiva height (mm) Article Number Implant connection Article Number Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 3,5-5,5 B 1400

D 3,5-5,5 0,5 B 4000

D 3,5-5,5 1,5 B 4100

D 3,5-5,5 2,5 B 4200

D 3,5-5,5 3,5 B 4300

D 3,5-5,5 4,5 B 4400

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

Titanium grade 5 KV

B 7600

B 4700

B 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" B 4720

MedentiBASE prosthetic components • B

MedentiCAD abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection Article Number Abutment screw Laboratory screw Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 3,5-5,5 B 900001 B 60 B 60 L

7600 MedentiBASE bridge screw Torx® T6 • B 4700 MedentiBASE titanium cap incl. bridge screw • B 4710 MedentiBASE plastic cap incl. bridge screw • B 4720 MedentiBASE gold cap, castable incl. bridge screw • B 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

Material Article Number

B 4840


20

» B-Series «

» B-Series «

Bredent Medical® SKY®

MedentiBASE adhesive cap for passive-fit

MedentiLOC abutment angled 15°

• B

• Titanium

4800 MedentiBASE adhesive cap Short incl. bridge screw • B 4810 MedentiBASE adhesive casing Short • B 4820 MedentiBASE adhesive cap Long incl. bridge screw • B 4830 MedentiBASE adhesive casing Long

21

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 25 Ncm • titanium

Version Article Number

Short B 4800

Short B 4810

Long B 4820

Long B 4830

Type 1

MedentiBASE scanbody • Titanium

grade 5 KV specially coated • incl. bridge screw

Implant connection D 3,5-5,5 D 3,5-5,5 D 3,5-5,5 D 3,5-5,5 D 3,5-5,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number B 2500-1 B 2600-1 B 2700-1 B 2800-1 B 2900-1 Abutment screw B 61 B 61 B 61 B 61 B 61 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

Novaloc Processing package Article Number Please note:

B 4900 The Scanbody is sterilisable and for intra-oral scanning.

• M

Article Number

B 4620

4630

• Matrix

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert • Retention

MedentiBASE accessories 11-6 Placement instrument MedentiBASE abutment • B 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

Bredent Medical® SKY®

M 11-6

Material Matrix housing Article Number Please note:

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

80

Placement instrument MedentiLOC abutment, angled

MedentiBASE finisher

• Hardened • Ball

• M

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head

Hex

stainless steel Version

Article Number Please note:

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capB 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

M 03-7

Version Article Number

straight 56

angled 57

steel

• Titanium

grade 5 KV nitride coated • Recommended torque: 25 Ncm • titanium

Implant connection D 3,5-5,5 D 3,5-5,5 D 3,5-5,5 D 3,5-5,5 D 3,5-5,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number B 2000 B 2100 B 2200 B 2300 B 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

Article Number

Manual and ratchet M 10-7

MedentiLOC Laboratory implant • Stainless

MedentiLOC abutment straight

Contra-angle

Abutment screw MedentiLOC abutment, angled • Titanium • Ball

Hex

grade 5 KV Article Number

B 61


22

» B-Series «

» B-Series «

Bredent Medical® SKY®

Insert Processing holder prosthetic • Stainless

steel

Implant connection Article Number

D 3,5-5,5 B 40

Processing holder, prosthetics • fits

all inserts steel

• Stainless

Article Number

M 04

Bredent Medical® SKY®

23


The BS-Series abutments are compatible with

» BS-SERIES «

BEGO Implant Systems® Semados® S-Line Semados® RS/RSX-Line Semados® RI-Line

DETAILANSICHT Genaue Ansicht der Abwinkelung (Indexierung) aller abgewinkelten Abutments.

Typ 1

Typ 2

abgewinkelt über Fläche

abgewinkelt über Eck

Products indicated with ® are registered brand names of respective manufactures.


26

» BS-Series «

» BS-Series «

BEGO Implant Systems® Semados S - RI - RS - RSX®

Laboratory implant CADCAM

Titanium base Zirconium abutment 2nd Generation

• Stainless

• Titanium

steel

grade 5 KV abutment screw • Recommended torque: 30 Ncm

D 5,5 BS 83

Implant connection D 4,1 Chimney height 5.5 (mm) Gingiva height (mm) 0,1 Article Number BS 1110 Abutment screw BS 60 Laboratory screw BS 60 L Please note: This is used with Scanbody 2. generation.

Placement instrument laboratory implant CADCAM steel

D 3,25-5,5 BS 80 T

1.26

0,1 BS 1120 BS 60 BS 60 L

0,1 BS 1130 BS 60 BS 60 L

D 4,1 3.5

D 4,5 3.5

0,15 BS 1510 BS 60 BS 60 L

0,15 BS 1520 BS 60 BS 60 L

D 3,25-5,5 11.5 BS 9000-R BS 60 BS 60 L

D 3,25-5,5 16.0 BS 9000-16R BS 60 BS 60 L

• Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

grade 5 KV

Article Number

BS 60

Laboratory screw • red

D 5,5 5.5

• rotating

Abutment screw • Hex

D 4,5 5.5

Titanium base Bridges/ bars 2nd Generation Implant connection Article Number

• Titanium

27

• incl.

Implant connection D 3,25/3,75 D 4,1 D 4,5 Article Number BS 80 BS 81 BS 82 Please note: This is used for 3D printmodels with Scanbody 2. generation.

• Stainless

BEGO Implant Systems® Semados S - RI - RS - RSX®

PreFace® abutment

coated

• Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Article Number

BS 60 L

Titanium base Zirconium abutment 2nd Generation

Implant connection Diameter (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

• Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Implant connection D 4,1 Chimney height 3.5 (mm) Gingiva height (mm) 0,1 Article Number BS 1010 Abutment screw BS 60 Laboratory screw BS 60 L Please note: This is used with Scanbody 2. generation.

D 4,5 3.5

D 5,5 3.5

0,1 BS 1020 BS 60 BS 60 L

0,1 BS 1030 BS 60 BS 60 L


28

» BS-Series «

BEGO Implant Systems® Semados S - RI - RS - RSX®

PreFace® abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 30 Ncm • incl.

Implant connection Diameter (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,25-5,5 16.0 BS 9800-16R BS 60 BS 60 L

Scanbody 2nd Generation • Titanium

grade 5 KV coated • incl. retention screw • specially

Implant connection Article Number Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 3,25-5,5 BS 1400

Implant connection D 3,25/3,75 D 4,1 D 4,5 Article Number BS 900001 BS 901001 BS 902001 Abutment screw BS 60 BS 60 BS 60 Laboratory screw BS 60 L BS 60 L BS 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,5 BS 903001 BS 60 BS 60 L

Implant connection D 3,25/3,75 D 4,1 D 4,5 Article Number BS 900004 BS 901004 BS 902004 Abutment screw BS 60 BS 60 BS 60 Laboratory screw BS 60 L BS 60 L BS 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,5 BS 903004 BS 60 BS 60 L

MedentiCAD abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

MedentiCAD abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 30 Ncm • incl.


The C-Series abutments are compatible with

» C-SERIES «

Altatec® Camlog Screw-Line – Root-Line 2®

DETAILANSICHT Genaue Ansicht der Abwinkelung (Indexierung) aller abgewinkelten Abutments.

Typ 1 abgewinkelt über Fläche

Typ 2 abgewinkelt über Nocke

Products indicated with ® are registered brand names of respective manufactures.


32

» C-Series «

Altatec® Camlog Screw-Line - Root-Line 2®

» C-Series «

Laboratory implant CADCAM

Titanium base Zirconium abutment 2nd Generation

• Stainless

• Titanium

steel

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection D 3,3 D 3,8 D 4,3 D 5,0 Article Number C 80 C 81 C 82 C 83 Please note: This is used for 3D printmodels with Scanbody 2. generation.

D 6,0 C 84

Implant connection D 3,3 D 3,8 D 4,3 Chimney height 5.5 5.5 5.5 (mm) Gingiva height (mm) 0,3 0,3 0,3 Article Number C 1100 C 1110 C 1120 Abutment screw C 61 C 61 C 61 Laboratory screw C 61 L C 61 L C 61 L Please note: This is used with Scanbody 2. generation.

Placement instrument laboratory implant CADCAM • Stainless

steel

D 3,3 C 80 T

D 3,8 C 81 T

D 4,3 C 82 T

D 5,0/6,0 C 83 T

1.26

0,3 C 1130 C 62 C 62 L

0,3 C 1140 C 62 C 62 L

D 3,8 3.5

D 4,3 3.5

0,3 C 1510 C 60

0,3 C 1520 C 60

D 3,8 16.0 C 9010-16R C 61 C 61 L

D 4,3 11.5 C 9020-R C 61 C 61 L

• Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection D 3,3 Chimney height 3.5 (mm) Gingiva height (mm) 0,3 Article Number C 1500 Abutment C 60 Please note: This is used with Scanbody 2. generation.

grade 5 KV

Article Number

C 60

C 61

C 62

Laboratory screw • red

D 6,0 5.5

• rotating

Abutment screw • Hex

D 5,0 5.5

Titanium base Bridges/ bars 2nd Generation Implant connection Article Number

• Titanium

Altatec® Camlog Screw-Line - Root-Line 2®

PreFace® abutment

coated

• Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Article Number

C 61 L

C 62 L Implant connection D 3,3 D 3,3 D 3,8 Diameter (mm) 11.5 16.0 11.5 Article Number C 9000-R C 9000-16R C 9010-R Abutment screw C 61 C 61 C 61 Laboratory screw C 61 L C 61 L C 61 L Please note: This is used with Scanbody 2. generation.

Titanium base Zirconium abutment 2nd Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection D 3,3 D 3,8 D 4,3 Chimney height 3.5 3.5 3.5 (mm) Gingiva height (mm) 0,3 0,3 0,3 Article Number C 1000 C 1010 C 1020 Abutment screw C 61 C 61 C 61 Laboratory screw C 61 L C 61 L C 61 L Please note: This is used with Scanbody 2. generation.

D 5,0 3.5

D 6,0 3.5

0,3 C 1030 C 62 C 62 L

0,3 C 1040 C 62 C 62 L

33


34

» C-Series «

Altatec® Camlog Screw-Line - Root-Line 2®

» C-Series «

PreFace® abutment

MedentiCAD abutment

• Titanium

• CrCo

Altatec® Camlog Screw-Line - Root-Line 2®

alloy / CTE 14.1 abutment screw • Recommended torque: 20 Ncm

grade 5 KV abutment screw • Recommended torque: 20 Ncm

• incl.

• incl.

Implant connection D 4,3 D 5,0 D 5,0 Diameter (mm) 16.0 11.5 16.0 Article Number C 9020-16R C 9030-R C 9030-16R Abutment screw C 61 C 62 C 62 Laboratory screw C 61 L C 62 L C 62 L Please note: This is used with Scanbody 2. generation.

D 6,0 11.5 C 9040-R C 62 C 62 L

Implant connection D 3,3 D 3,8 D 4,3 D 5,0 Article Number C 900004 C 901004 C 902004 C 903004 Abutment screw C 61 C 61 C 61 C 62 Laboratory screw C 61 L C 61 L C 61 L C 62 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 6,0 16.0 C 9040-16R C 62 C 62 L

PreFace® abutment

MedentiBASE abutment straight

• CrCo

• Titanium

alloy / CTE 14.1 abutment screw • Recommended torque: 20 Ncm • incl.

D 6,0 C 904004 C 62 C 62 L

grade 5 KV torque: 20 Ncm

• Recommended

Implant connection D 3,3 D 3,8 D 4,3 Diameter (mm) 16.0 16.0 16.0 Article Number C 9800-16R C 9810-16R C 9820-16R Abutment screw C 61 C 61 C 61 Laboratory screw C 61 L C 61 L C 61 L Please note: This is used with Scanbody 2. generation.

D 5,0 16.0 C 9830-16R C 62 C 62 L

D 6,0 16.0 C 9840-16R C 62 C 62 L

Implant connection Gingiva height (mm) Article Number

D 3,3 0,5 C 4000

D 3,3 1,5 C 4100

D 3,3 2,5 C 4200

D 3,3 3,5 C 4300

D 3,3 4,5 C 4400

Implant connection Gingiva height (mm) Article Number

D 3,8 0,5 C 4010

D 3,8 1,5 C 4110

D 3,8 2,5 C 4210

D 3,8 3,5 C 4310

D 3,8 4,5 C 4410

Implant connection Gingiva height (mm) Article Number

D 4,3 0,5 C 4020

D 4,3 1,5 C 4120

D 4,3 2,5 C 4220

D 4,3 3,5 C 4320

D 4,3 4,5 C 4420

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 30 Ncm

• Recommended

Scanbody 2 Generation nd

• Titanium

grade 5 KV coated • incl. retention screw • specially

Implant connection D 3,3 D 3,8 D 4,3 Article Number C 1400 C 1410 C 1420 Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 5,0/6,0 C 1430

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 30 Ncm

• Recommended

MedentiCAD abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection D 3,3 D 3,8 D 4,3 D 5,0 Article Number C 900001 C 901001 C 902001 C 903001 Abutment screw C 61 C 61 C 61 C 62 Laboratory screw C 61 L C 61 L C 61 L C 62 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 6,0 C 904001 C 62 C 62 L

35


36

» C-Series «

» C-Series «

Altatec® Camlog Screw-Line - Root-Line 2®

MedentiBASE prosthetic components

MedentiLOC abutment straight

• C

• Titanium

7600 MedentiBASE bridge screw Hex 1.26 • C 4700 MedentiBASE titanium cap incl. bridge screw • C 4710 MedentiBASE plastic cap incl. bridge screw • C 4720 MedentiBASE gold cap, castable incl. bridge screw • C 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

grade 5 KV nitride coated • Recommended torque: 20 Ncm • titanium

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

C 7600

C 4700

C 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" C 4720

Titanium grade 5 KV Implant connection D 3,3 D 3,3 D 3,3 D 3,3 D 3,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number C 2000 C 2100 C 2200 C 2300 C 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

C 4840

MedentiBASE adhesive cap for passive-fit 4800 MedentiBASE adhesive cap Short incl. bridge screw • C 4810 MedentiBASE adhesive casing Short • C 4820 MedentiBASE adhesive cap Long incl. bridge screw • C 4830 MedentiBASE adhesive casing Long

Altatec® Camlog Screw-Line - Root-Line 2®

MedentiLOC abutment straight

• C

• Titanium

grade 5 KV nitride coated • Recommended torque: 30 Ncm • titanium

Version Article Number

Short C 4800

Short C 4810

Long C 4820

Long C 4830 Implant connection D 3,8 D 3,8 D 3,8 D 3,8 D 3,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number C 2010 C 2110 C 2210 C 2310 C 2410 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

MedentiBASE scanbody • Titanium

grade 5 KV specially coated • incl. bridge screw

MedentiLOC abutment straight Article Number Please note:

C 4900 The Scanbody is sterilisable and for intra-oral scanning.

• Titanium

grade 5 KV nitride coated • Recommended torque: 30 Ncm • titanium

MedentiBASE accessories 11-6 Placement instrument MedentiBASE abutment • C 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

Implant connection D 4,3 D 4,3 D 4,3 D 4,3 D 4,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number C 2020 C 2120 C 2220 C 2320 C 2420 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• M

Article Number

C 4620

4630

M 11-6

80

MedentiLOC abutment straight

MedentiBASE finisher

• Titanium

grade 5 KV nitride coated • Recommended torque: 30 Ncm • titanium

• M

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head Article Number Please note:

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capC 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

Implant connection D 5,0 D 5,0 D 5,0 D 5,0 D 5,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number C 2030 C 2130 C 2230 C 2330 C 2430 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

37


38

» C-Series «

Altatec® Camlog Screw-Line - Root-Line 2®

» C-Series «

MedentiLOC abutment straight

Novaloc abutment straight

• Titanium

• Titanium

grade 5 KV nitride coated • Recommended torque: 30 Ncm

grade 5 KV coated • Recommended torque: 30 Ncm

• titanium

• LTC

Implant connection D 6,0 D 6,0 D 6,0 D 6,0 D 6,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number C 2040 C 2140 C 2240 C 2340 C 2440 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

Implant connection D 3,8 D 3,8 D 3,8 D 3,8 D 3,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number C 6010 C 6110 C 6210 C 6310 C 6410 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Novaloc Processing package

Novaloc abutment straight

• Matrix

• Titanium

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

grade 5 KV coated • Recommended torque: 30 Ncm

• Retention

• LTC

Material Matrix housing Article Number Please note:

Titanium

Peek

Implant connection D 4,3 D 4,3 D 4,3 D 4,3 D 4,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number C 6020 C 6120 C 6220 C 6320 C 6420 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

MedentiLOC Laboratory implant • Stainless

Altatec® Camlog Screw-Line - Root-Line 2®

Novaloc Processing package

steel

• Matrix

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert • Retention

Version Article Number

straight 56

Novaloc abutment straight grade 5 KV coated • Recommended torque: 20 Ncm

Material Matrix housing Article Number Please note:

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

• Titanium • LTC

Novaloc Laboratory implant Implant connection D 3,3 D 3,3 D 3,3 D 3,3 D 3,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number C 6000 C 6100 C 6200 C 6300 C 6400 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

• Stainless

steel

Version Article Number

straight 58

39


40

» C-Series «

Altatec® Camlog Screw-Line - Root-Line 2®

Optiloc abutment straight

» C-Series «

Altatec® Camlog Screw-Line - Root-Line 2®

Placement instrument Optiloc abutment

• Titanium

grade 5 KV coated • Recommended torque: 20 Ncm • LTC

• Hardened

stainless steel

Version Implant connection D 3,3 D 3,3 D 3,3 D 3,3 D 3,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number C 5000 C 5100 C 5200 C 5300 C 5400 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Article Number

Manual and ratchet M 59

Optiloc implant analogue • Aluminium

Optiloc abutment straight • Titanium

grade 5 KV coated • Recommended torque: 30 Ncm • LTC

Version Article Number

Implant connection D 3,8 D 3,8 D 3,8 D 3,8 D 3,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number C 5010 C 5110 C 5210 C 5310 C 5410 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Optiloc abutment straight • Titanium

grade 5 KV coated • Recommended torque: 30 Ncm • LTC

Implant connection D 4,3 D 4,3 D 4,3 D 4,3 D 4,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number C 5020 C 5120 C 5220 C 5320 C 5420 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Optiloc Processing package • Matrix

housing, titanium insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • Retention

Material Matrix housing Article Number Please note:

Titanium 5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.

4 piece 2102.0024

41


The CX-Series abutments are compatible with

» CX-SERIES «

Medentis Medical® ICX®

DETAILANSICHT Genaue Ansicht der Abwinkelung (Indexierung) aller abgewinkelten Abutments.

Typ 1

Typ 2

abgewinkelt über Fläche

abgewinkelt über Eck

Products indicated with ® are registered brand names of respective manufactures.


44

» CX-Series «

» CX-Series «

Medentis Medical® ICX®

Laboratory implant CADCAM

Titanium base Zirconium abutment 2nd Generation

• Stainless

• Titanium

steel

grade 5 KV abutment screw • Recommended torque: 30 Ncm

D 3,75-4,8 CX 80

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

Placement instrument laboratory implant CADCAM steel

D 3,75-4,8 CX 80 T

1,4

0,65 CX 1100 CX 60 CX 60 L

1,15 CX 1300 CX 60 CX 60 L

• Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

grade 5 KV

Article Number

CX 60

Laboratory screw • red

D 3,75-4,8 5.5

• rotating

Abutment screw • Hex

D 3,75-4,8 5.5

Titanium base Bridges/ bars 2nd Generation Implant connection Article Number

• Titanium

45

• incl.

Implant connection Article Number Please note: This is used for 3D printmodels with Scanbody 2. generation.

• Stainless

Medentis Medical® ICX®

D 3,75-4,8 3.5 0,65 CX 1500 CX 60 CX 60 L

PreFace® abutment

coated

• Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Article Number

CX 60 L

Titanium base Zirconium abutment 2nd Generation

Implant connection Diameter (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

• Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,75-4,8 3.5

D 3,75-4,8 3.5

0,65 CX 1000 CX 60 CX 60 L

1,15 CX 1200 CX 60 CX 60 L

D 3,75-4,8 11.5 CX 9000-R CX 60 CX 60 L

D 3,75-4,8 16.0 CX 9000-16R CX 60 CX 60 L


46

» CX-Series «

Medentis Medical® ICX®

PreFace® abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 30 Ncm • incl.

Implant connection Diameter (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,75-4,8 16.0 CX 9800-16R CX 60 CX 60 L

Scanbody 2nd Generation • Titanium

grade 5 KV coated • incl. retention screw • specially

Implant connection Article Number Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 3,75-4,8 CX 1400

Implant connection Article Number Abutment screw Laboratory screw Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 3,75-4,8 CX 900001 CX 60 CX 60 L

Implant connection Article Number Abutment screw Laboratory screw Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 3,75-4,8 CX 900004 CX 60 CX 60 L

MedentiCAD abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

MedentiCAD abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 30 Ncm • incl.


The D-Series abutments are compatible with

» D-SERIES «

Altatec® Conelog®

DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments.

Type 1

Type 2

angled over flat

angled over cam

Products indicated with ® are registered brand names of respective manufactures.


50

» D-Series «

» D-Series «

Altatec® Conelog®

Laboratory implant

Temporary abutment

• Stainless

• Titanium

steel

51

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection Article Number

D 3,3 D 50

D 3,8/4,3 D 51

Laboratory implant CADCAM • Stainless

Altatec® Conelog®

Implant connection Article Number Abutment screw Laboratory screw

D 3,3 D 3500 D 60 D 60 L

D 3,8/4,3 D 3510 D 60 D 60 L

Implant connection D 3,3 D 3,3 Chimney height 3.5 3.5 (mm) Gingiva height (mm) 0,65 1,15 Article Number D 1000 D 1200 Abutment screw D 60 D 60 Laboratory screw D 60 L D 60 L Please note: This is used with Scanbody 2. generation.

D 3,8/4,3 3.5

D 3,8/4,3 3.5

0,65 D 1010 D 60 D 60 L

1,15 D 1210 D 60 D 60 L

Implant connection D 3,3 D 3,3 Chimney height 5.5 5.5 (mm) Gingiva height (mm) 0,65 1,15 Article Number D 1100 D 1300 Abutment screw D 60 D 60 Laboratory screw D 60 L D 60 L Please note: This is used with Scanbody 2. generation.

D 3,8/4,3 5.5

D 3,8/4,3 5.5

0,65 D 1110 D 60 D 60 L

1,15 D 1310 D 60 D 60 L

Titanium base Zirconium abutment 2nd Generation

steel

• Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection D 3,3 Article Number D 80 Please note: This is used for 3D printmodels with Scanbody 2. generation.

D 3,8/4,3 D 81

Placement instrument laboratory implant CADCAM • Stainless

steel

Implant connection Article Number

D 3,3 D 80 T

D 3,8/4,3 D 81 T

Titanium base Zirconium abutment 2nd Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Abutment screw • Titanium • Hex

1.26

grade 5 KV

Article Number

D 60

Article Number

D 60 L

Laboratory screw • red

coated


52

» D-Series «

» D-Series «

Altatec® Conelog®

Altatec® Conelog®

53

MedentiCAD abutment

Titanium base Bridges/ bars 2nd Generation

• Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

• rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,3 3.5

D 3,8/4,3 3.5

0,65 D 1500 D 60 D 60 L

0,65 D 1510 D 60 D 60 L

Implant connection D 3,3 Article Number D 900001 Abutment screw D 60 Laboratory screw D 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 3,8/4,3 D 901001 D 60 D 60 L

Implant connection D 3,3 Article Number D 900004 Abutment screw D 60 Laboratory screw D 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 3,8/4,3 D 901004 D 60 D 60 L

Implant connection Article Number Please note: For use on the model only!

D 3,3 D 9100

D 3,8/4,3 D 9110

D 3,3 3,5 D 4300

D 3,3 4,5 D 4400

MedentiCAD abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 20 Ncm • incl.

PreFace abutment ®

• Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection D 3,3 Diameter (mm) 11.5 Article Number D 9000-R Abutment screw D 60 D 60 L Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,8/4,3 11.5 D 9010-R D 60 D 60 L

D 3,8/4,3 16.0 D 9010-16R D 60 D 60 L

MedentiCAD wax-up base • Steel • incl.

abutment screw

PreFace abutment ®

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection Diameter (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,3 11.5 D 9800-R D 60 D 60 L

D 3,8/4,3 16.0 D 9810-16R D 60 D 60 L

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 20 Ncm

• Recommended

Scanbody 2nd Generation Implant connection Gingiva height (mm) Article Number

• Titanium

grade 5 KV coated • incl. retention screw • specially

Implant connection D 3,3 Article Number D 1400 Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 3,8/4,3 D 1410

D 3,3 0,5 D 4000

D 3,3 1,5 D 4100

D 3,3 2,5 D 4200


54

» D-Series «

» D-Series «

Altatec® Conelog®

MedentiBASE abutment straight • Titanium

MedentiBASE finisher • M

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head

grade 5 KV torque: 20 Ncm

• Recommended

Implant connection Gingiva height (mm) Article Number

D 3,8/4,3 0,5 D 4010

D 3,8/4,3 1,5 D 4110

D 3,8/4,3 2,5 D 4210

D 3,8/4,3 3,5 D 4310

D 3,8/4,3 4,5 D 4410

MedentiBASE prosthetic components 7600 MedentiBASE bridge screw Hex 1.26 • D 4700 MedentiBASE titanium cap incl. bridge screw • D 4710 MedentiBASE plastic cap incl. bridge screw • D 4720 MedentiBASE gold cap, castable incl. bridge screw • D 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

Article Number Please note:

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capD 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 20 Ncm • titanium

• D

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

D 7600

D 4700

D 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" D 4720

Implant connection D 3,3 D 3,3 D 3,3 D 3,3 D 3,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number D 2000 D 2100 D 2200 D 2300 D 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

Titanium grade 5 KV D 4840

MedentiLOC abutment straight

MedentiBASE adhesive cap for passive-fit 4800 MedentiBASE adhesive cap Short incl. bridge screw • D 4810 MedentiBASE adhesive casing Short • D 4820 MedentiBASE adhesive cap Long incl. bridge screw • D 4830 MedentiBASE adhesive casing Long

Altatec® Conelog®

• Titanium

grade 5 KV nitride coated • Recommended torque: 20 Ncm • titanium

• D

Version Article Number

Short D 4800

Short D 4810

Long D 4820

Long D 4830

Implant connection D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number D 2010 D 2110 D 2210 D 2310 D 2410 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

MedentiBASE scanbody MedentiLOC abutment angled 15°

• Titanium

grade 5 KV specially coated • incl. bridge screw

• Titanium

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Type 2 = angled over cam • Recommended torque: 20 Ncm • titanium

Article Number Please note:

D 4900 The Scanbody is sterilisable and for intra-oral scanning.

MedentiBASE accessories 11-6 Placement instrument MedentiBASE abutment • D 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

Type 1

• M

Type 2

Article Number

D 4620

4630

M 11-6

80

Implant connection D 3,3 D 3,3 D 3,3 D 3,3 D 3,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article No. Type 1 D 2500-1 D 2600-1 D 2700-1 D 2800-1 D 2900-1 Article No. Type 2 D 2500-2 D 2600-2 D 2700-2 D 2800-2 D 2900-2 Abutment screw D 61 D 61 D 61 D 61 D 61 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

55


56

» D-Series «

» D-Series «

Altatec® Conelog®

MedentiLOC abutment angled 15°

Novaloc abutment straight

• Titanium

• Titanium

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Type 2 = angled over cam • Recommended torque: 20 Ncm Type 2

• LTC

Implant connection D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article No. Type 1 D 2510-1 D 2610-1 D 2710-1 D 2810-1 D 2910-1 Article No. Type 2 D 2510-2 D 2610-2 D 2710-2 D 2810-2 D 2910-2 Abutment screw D 61 D 61 D 61 D 61 D 61 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

Novaloc Processing package housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

57

grade 5 KV coated • Recommended torque: 20 Ncm

• titanium

Type 1

Altatec® Conelog®

Implant connection D 3,3 D 3,3 D 3,3 D 3,3 D 3,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number D 6000 D 6100 D 6200 D 6300 D 6400 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Novaloc abutment straight • Titanium

grade 5 KV coated • Recommended torque: 20 Ncm • LTC

• Matrix

• Retention

Material Matrix housing Article Number Please note:

Titanium

Implant connection D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number D 6010 D 6110 D 6210 D 6310 D 6410 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Novaloc Processing package

Placement instrument MedentiLOC abutment, angled • Hardened • Ball

Hex

• Matrix

stainless steel Version Article Number

Contra-angle M 03-7

Manual and ratchet M 10-7

MedentiLOC Laboratory implant • Stainless

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert • Retention

Version Article Number

straight 56

angled 57

Abutment screw MedentiLOC abutment, angled • Ball

Hex

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Novaloc Laboratory implant

steel

• Stainless

• Titanium

Material Matrix housing Article Number Please note:

grade 5 KV Article Number

D 61

steel

Version Article Number

straight 58


58

» D-Series «

» D-Series «

Altatec® Conelog®

Optiloc abutment straight

Altatec® Conelog®

59

Insert Processing holder prosthetic

• Titanium

grade 5 KV coated • Recommended torque: 20 Ncm • LTC

• Stainless

Implant connection D 3,3 D 3,3 D 3,3 D 3,3 D 3,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number D 5000 D 5100 D 5200 D 5300 D 5400 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Optiloc abutment straight

steel

Implant connection Article Number

D 3,3 D 40

Processing holder, prosthetics • fits

all inserts steel

• Stainless

• Titanium

grade 5 KV coated • Recommended torque: 20 Ncm • LTC

Article Number

Implant connection D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 D 3,8/4,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number D 5010 D 5110 D 5210 D 5310 D 5410 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Optiloc Processing package • Matrix

housing, titanium insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • Retention

Material Matrix housing Article Number Please note:

Titanium 5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument Optiloc abutment • Hardened

stainless steel

Version Article Number

Manual and ratchet M 59

Optiloc implant analogue • Aluminium

Version Article Number

4 piece 2102.0024

M 04

D 3,8/4,3 D 41


The E-Series abutments are compatible with

» E-SERIES «

Nobel Biocare NobelReplace® Tapered

DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments.

Type 1

Type 2

angled over flat

angled over cam

Products indicated with ® are registered brand names of respective manufactures.


62

» E-Series «

» E-Series «

Nobel Biocare® NobelReplace Tapered®

Implant pick-up Open tray

Abutment screw

• incl.

• Titanium

retention screw steel

• Stainless

• UG

Implant connection Version Article Number

NP 3,5 short E 10

RP 4,3 short E 11

WP 5,0 short E 12

Nobel Biocare® NobelReplace Tapered®

63

grade 5 KV

Article Number

E 60

E 61

Article Number

E 60 L

E 61 L

Laboratory screw • red

coated

Implant pick-up Open tray • incl.

retention screw steel

• Stainless

Temporary abutment • Titanium

Implant connection Version Article Number

NP 3,5 long E 20

RP 4,3 long E 21

WP 5,0 long E 22

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Laboratory implant • Stainless

steel

Implant connection Article Number

NP 3,5 E 50

RP 4,3 E 51

WP 5,0 E 52

D 6,0 E 53

Implant connection Article Number Abutment screw Laboratory screw

NP 3,5 E 3500 E 60 E 60 L

RP 4,3 E 3510 E 61 E 61 L

WP 5,0 E 3520 E 61 E 61 L

Implant connection Article Number Abutment screw Laboratory screw

NP 3,5 E 3700 E 60 E 60 L

RP 4,3 E 3710 E 61 E 61 L

WP 5,0 E 3720 E 61 E 61 L

RP 4,3 1,0 4,5 E 110-1 E 61 E 61 L

WP 5,0 1,0 5,6 E 120-1 E 61 E 61 L

D 6,0 1,0 6,2 E 130-1 E 61 E 61 L

Temporary abutment rotating • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Laboratory implant CADCAM • Stainless

steel

Implant connection NP 3,5 RP 4,3 WP 5,0 Article Number E 80 E 81 E 82 Please note: This is used for 3D printmodels with Scanbody 2. generation.

D 6,0 E 83

Standard abutment straight • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Placement instrument laboratory implant CADCAM • Stainless

steel

Implant connection Article Number

NP 3,5 E 80 T

RP 4,3 E 81 T

WP 5,0 E 82 T

D 6,0 E 83 T

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

NP 3,5 1,0 3,7 E 100-1 E 60 E 60 L


64

» E-Series «

» E-Series «

Nobel Biocare® NobelReplace Tapered®

Standard abutment straight

Castable gold abutment rotating

• Titanium

• AU

grade 5 KV abutment screw • Recommended torque: 35 Ncm

Nobel Biocare® NobelReplace Tapered®

65

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm

• incl.

• incl.

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

NP 3,5 2,5 4,5 E 100 E 60 E 60 L

RP 4,3 2,5 5,3 E 110 E 61 E 61 L

WP 5,0 2,5 5,5 E 120 E 61 E 61 L

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

D 6,0 2,5 6,5 E 130 E 61 E 61 L

NP 3,5 0,30 E 300 R E 60 E 60 L

RP 4,3 0,48 E 310 R E 61 E 61 L

WP 5,0 0,56 E 320 R E 61 E 61 L

Solid abutment straight

Standard abutment angled 16°

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over cam • Recommended torque: 35 Ncm • incl.

Type 1

Type 2

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

NP 3,5 1,0 3,7 E 200-1-1 E 200-2-1 E 60 E 60 L

RP 4,3 1,0 4,5 E 210-1-1 E 210-2-1 E 61 E 61 L

WP 5,0 1,0 5,2 E 220-1-1 E 220-2-1 E 61 E 61 L

D 6,0 1,0 6,2 E 230-1-1 E 230-2-1 E 61 E 61 L

WP 5,0 3,5 5,8 E 520-1 E 520-2 E 61 E 61 L

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over cam • Recommended torque: 35 Ncm • incl.

grade 5 KV • incl. abutment screw • Type 1 = angled over flat • Type 2 = angled over cam • Recommended torque: 35 Ncm

Implant connection NP 3,5 RP 4,3 Gingiva height (mm) 3,5 3,5 Diameter (mm) 4,6 5,0 Article No. Type 1 E 500-1 E 510-1 Article No. Type 2 E 500-2 E 510-2 Abutment screw E 60 E 61 Laboratory screw E 60 L E 61 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

• Titanium

• Titanium

Type 2

D 6,0 3,5 6,0 E 430 E 61 E 61 L

Solid abutment angled 18°

Standard abutment angled 16°

Type 1

Implant connection NP 3,5 RP 4,3 WP 5,0 Gingiva height (mm) 3,5 3,5 3,5 Diameter (mm) 4,8 5,0 5,8 Article Number E 400 E 410 E 420 Abutment screw E 60 E 61 E 61 Laboratory screw E 60 L E 61 L E 61 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

Type 1

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

NP 3,5 2,5 4,5 E 200-1 E 200-2 E 60 E 60 L

RP 4,3 2,5 4,8 E 210-1 E 210-2 E 61 E 61 L

WP 5,0 2,5 5,5 E 220-1 E 220-2 E 61 E 61 L

D 6,0 2,5 6,5 E 230-1 E 230-2 E 61 E 61 L

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

NP 3,5 0,37 E 300 E 60 E 60 L

RP 4,3 0,63 E 310 E 61 E 61 L

WP 5,0 0,77 E 320 E 61 E 61 L

D 6,0 1,33 E 330 E 61 E 61 L

Castable gold abutment • AU

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm • incl.

Type 2


66

» E-Series «

» E-Series «

Nobel Biocare® NobelReplace Tapered®

POC abutment

67

Titanium base Zirconium abutment 1st Generation

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 RP 4,3 WP 5,0 Article Number E 900 E 910 E 920 Abutment screw E 60 E 61 E 61 Laboratory screw E 60 L E 61 L E 61 L Please note: For pressing on a individual ceramics Emergence profile.

D 6,0 E 930 E 61 E 61 L

Implant connection NP 3,5 Chimney height 4,0 (mm) Gingiva height (mm) 0,4 Article Number E 800 LV Abutment screw E 60 Laboratory screw E 60 L Please note: Just for use with 3M ESPE Lava™.

Pulse opaque • POC

Nobel Biocare® NobelReplace Tapered®

RP 4,3 4,0

WP 5,0 4,0

D 6,0 4,0

0,4 E 810 LV E 61 E 61 L

0,4 E 820 LV E 61 E 61 L

0,4 E 830 LV E 61 E 61 L

Implant connection NP 3,5 RP 4,3 Article Number E 00 W E 10 W Please note: This is used for Titanium base 1. generation.

WP 5,0 E 20 W

D 6,0 E 30 W

Implant connection NP 3,5 RP 4,3 Chimney height 3.5 3.5 (mm) Gingiva height (mm) 0,3 0,3 Article Number E 1000 E 1010 Abutment screw E 60 E 61 Laboratory screw E 60 L E 61 L Please note: This is used with Scanbody 2. generation.

WP 5,0 3.5

D 6,0 3.5

0,3 E 1020 E 61 E 61 L

0,3 E 1030 E 61 E 61 L

abutment

Scanbody 1st Generation • Peek • incl.

Amount Article Number Please note:

retention screw

4 grams OP 90 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Pulse press blank • POC

abutment

Colour Article Number Please note:

A3 B2 C2 D2 A2 P 90 P 91 P 92 P 93 P 94 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 RP 4,3 Chimney height 4,0 4,0 (mm) Gingiva height (mm) 0,4 0,4 Article Number E 800 E 810 Abutment screw E 60 E 61 Laboratory screw E 60 L E 61 L Please note: This is used with Scanbody 1. generation.

WP 5,0 4,0

D 6,0 4,0

0,4 E 820 E 61 E 61 L

0,4 E 830 E 61 E 61 L

Titanium base Zirconium abutment 2nd Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.


68

» E-Series «

» E-Series «

Nobel Biocare® NobelReplace Tapered®

Titanium base Zirconium abutment 2nd Generation

PreFace® abutment

• Titanium

• incl.

Nobel Biocare® NobelReplace Tapered®

69

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 RP 4,3 Chimney height 5.5 5.5 (mm) Gingiva height (mm) 0,3 0,3 Article Number E 1100 E 1110 Abutment screw E 60 E 61 Laboratory screw E 60 L E 61 L Please note: This is used with Scanbody 2. generation.

WP 5,0 5.5

D 6,0 5.5

0,3 E 1120 E 61 E 61 L

0,3 E 1130 E 61 E 61 L

Implant connection NP 3,5 Diameter (mm) 11.5 Article Number E 9800-R Abutment screw E 60 Laboratory screw E 60 L Please note: This is used with Scanbody 2. generation.

RP 4,3 16.0 E 9810-16R E 61 E 61 L

WP 5,0 16.0 E 9820-16R E 61 E 61 L

Scanbody 2nd Generation Titanium base Bridges/ bars 2nd Generation

• Titanium

grade 5 KV coated • incl. retention screw • specially

• rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 Chimney height 3.5 (mm) Gingiva height (mm) 0,3 Article Number E 1500 Abutment screw E 60 Laboratory screw E 60 L Please note: This is used with Scanbody 2. generation.

RP 4,3 3.5

WP 5,0 3.5

0,3 E 1510 E 61 E 61 L

0,3 E 1520 E 61 E 61 L

Implant connection NP 3,5 RP 4,3 WP 5,0 Article Number E 1400 E 1410 E 1420 Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 6,0 E 1430

MedentiCAD abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

PreFace® abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 RP 4,3 RP 4,3 Diameter (mm) 11.5 11.5 16.0 Article Number E 9000-R E 9010-R E 9010-16R Abutment screw E 60 E 61 E 61 Laboratory screw E 60 L E 61 L E 61 L Please note: This is used with Scanbody 2. generation.

WP 5,0 11.5 E 9020-R E 61 E 61 L

WP 5,0 16.0 E 9020-16R E 61 E 61 L

Implant connection NP 3,5 RP 4,3 WP 5,0 Article Number E 900001 E 901001 E 902001 Abutment screw E 60 E 61 E 61 Laboratory screw E 60 L E 61 L E 61 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 6,0 E 903001 E 61 E 61 L

Implant connection NP 3,5 RP 4,3 Article Number E 900004 E 901004 Abutment screw E 60 E 61 Laboratory screw E 60 L E 61 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

WP 5,0 E 902004 E 61 E 61 L

MedentiCAD abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.


70

» E-Series «

» E-Series «

Nobel Biocare® NobelReplace Tapered®

MedentiCAD wax-up base

MedentiBASE scanbody

• Steel

• Titanium

• incl.

Nobel Biocare® NobelReplace Tapered®

71

grade 5 KV specially coated • incl. bridge screw

abutment screw

Implant connection NP 3,5 Article Number E 9100 Please note: For use on the model only!

RP 4,3 E 9110

WP 5,0 E 9120

Article Number Please note:

D 6,0 E 9130

E 4900 The Scanbody is sterilisable and for intra-oral scanning.

MedentiBASE accessories • M

11-6 Placement instrument MedentiBASE abutment • E 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 35 Ncm

• Recommended

Implant connection Gingiva height (mm) Article Number

NP 3,5 0,5 E 4000

NP 3,5 1,5 E 4100

NP 3,5 2,5 E 4200

NP 3,5 3,5 E 4300

NP 3,5 4,5 E 4400

MedentiBASE abutment straight • Titanium

RP 4,3 1,5 E 4110

RP 4,3 2,5 E 4210

RP 4,3 3,5 E 4310

RP 4,3 4,5 E 4410

80

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capE 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

MedentiBASE prosthetic components

Implant connection NP 3,5 NP 3,5 NP 3,5 NP 3,5 NP 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number E 2000 E 2100 E 2200 E 2300 E 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• E

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

E 7600

E 4700

E 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" E 4720

Titanium grade 5 KV E 4840

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

MedentiBASE adhesive cap for passive-fit 4800 MedentiBASE adhesive cap Short incl. bridge screw • E 4810 MedentiBASE adhesive casing Short • E 4820 MedentiBASE adhesive cap Long incl. bridge screw • E 4830 MedentiBASE adhesive casing Long

M 11-6

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head

grade 5 KV torque: 35 Ncm

RP 4,3 0,5 E 4010

4630

• M

Article Number Please note:

Implant connection Gingiva height (mm) Article Number

E 4620

MedentiBASE finisher

• Recommended

7600 MedentiBASE bridge screw UG • E 4700 MedentiBASE titanium cap incl. bridge screw • E 4710 MedentiBASE plastic cap incl. bridge screw • E 4720 MedentiBASE gold cap, castable incl. bridge screw • E 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

Article Number

Implant connection RP 4,3 RP 4,3 RP 4,3 RP 4,3 RP 4,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number E 2010 E 2110 E 2210 E 2310 E 2410 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• E

Version Article Number

Short E 4800

Short E 4810

Long E 4820

Long E 4830


72

» E-Series «

Nobel Biocare® NobelReplace Tapered®

» E-Series «

MedentiLOC abutment straight

Novaloc Processing package

• Titanium

• Matrix

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

Nobel Biocare® NobelReplace Tapered®

73

• Retention

Implant connection WP 5,0 WP 5,0 WP 5,0 WP 5,0 WP 5,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number E 2020 E 2120 E 2220 E 2320 E 2420 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

MedentiLOC abutment straight

Placement instrument MedentiLOC abutment, angled

• Titanium

• Hardened

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

• Ball

Hex

Material Matrix housing Article Number Please note:

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Contra-angle

Article Number

M 03-7

Manual and ratchet M 10-7

Version Article Number

straight 56

angled 57

Article Number

E 64

E 65

MedentiLOC Laboratory implant • Stainless

steel

MedentiLOC abutment angled 15° grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Type 2 = angled over cam • Recommended torque: 35 Ncm

Peek

stainless steel Version

Implant connection D 6,0 D 6,0 D 6,0 D 6,0 D 6,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number E 2030 E 2130 E 2230 E 2330 E 2430 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

Titanium

• Titanium • titanium

Type 1

Type 2

Implant connection NP 3,5 NP 3,5 NP 3,5 NP 3,5 NP 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article No. Type 1 E 2500-1 E 2600-1 E 2700-1 E 2800-1 E 2900-1 Article No. Type 2 E 2500-2 E 2600-2 E 2700-2 E 2800-2 E 2900-2 Abutment screw E 64 E 64 E 64 E 64 E 64 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

MedentiLOC abutment angled 15°

Abutment screw MedentiLOC abutment, angled • Titanium • Ball

Hex

grade 5 KV

Novaloc abutment straight • Titanium

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

• Titanium

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Type 2 = angled over cam • Recommended torque: 35 Ncm • titanium

Type 1

Type 2

Implant connection RP 4,3 RP 4,3 RP 4,3 RP 4,3 RP 4,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article No. Type 1 E 2510-1 E 2610-1 E 2710-1 E 2810-1 E 2910-1 Article No. Type 2 E 2510-2 E 2610-2 E 2710-2 E 2810-2 E 2910-2 Abutment screw E 65 E 65 E 65 E 65 E 65 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

Implant connection NP 3,5 NP 3,5 NP 3,5 NP 3,5 NP 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number E 6000 E 6100 E 6200 E 6300 E 6400 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.


74

» E-Series «

» E-Series «

Nobel Biocare® NobelReplace Tapered®

Novaloc abutment straight

Optiloc abutment straight

• Titanium

• LTC

75

• Titanium

grade 5 KV coated • Recommended torque: 35 Ncm

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

Implant connection RP 4,3 RP 4,3 RP 4,3 RP 4,3 RP 4,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number E 6010 E 6110 E 6210 E 6310 E 6410 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Implant connection RP 4,3 RP 4,3 RP 4,3 RP 4,3 RP 4,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number E 5010 E 5110 E 5210 E 5310 E 5410 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Novaloc Processing package

Optiloc Processing package

• Matrix

• Matrix

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

Nobel Biocare® NobelReplace Tapered®

housing, titanium insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package

• Retention

• Retention

Material Matrix housing Article Number Please note:

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Novaloc Laboratory implant

Placement instrument Optiloc abutment

• Stainless

• Hardened

steel

Version Article Number

Titanium 5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.

stainless steel

straight 58

Optiloc abutment straight

Material Matrix housing Article Number Please note:

Version

Manual and ratchet M 59

Article Number

Optiloc implant analogue

• Titanium

grade 5 KV • LTC coated • Recommended torque: 35 Ncm

• Aluminium

Implant connection NP 3,5 NP 3,5 NP 3,5 NP 3,5 NP 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number E 5000 E 5100 E 5200 E 5300 E 5400 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Version Article Number

4 piece 2102.0024

Planning abutment straight • Aluminium

red coated

Implant connection Gingiva height (mm) Diameter (mm) Article Number

NP 3,5 1,0/2,5 4,0 EP 100

RP 4,3 1,0/2,5 4,8 EP 110

WP 5,0 1,0/2,5 5,5 EP 120

D 6,0 1,0/2,5 6,5 EP 130


76

» E-Series «

Nobel Biocare® NobelReplace Tapered®

Planning abutment angled 16° • Aluminium

red coated 1 = angled over flat • Type 2 = angled over cam • Type

Type 1

Type 2

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2

NP 3,5 1,0/2,5 4,0 EP 200-1 EP 200-2

RP 4,3 1,0/2,5 4,8 EP 210-1 EP 210-2

WP 5,0 1,0/2,5 5,5 EP 220-1 EP 220-2

D 6,0 1,0/2,5 6,5 EP 230-1 EP 230-2

Planning abutment set • 12

piece

Article Number Content:

EPS EP 100, EP 110, EP 120, EP 130, EP 200-1, EP 200-2, EP 210-1, EP 210-2, EP 220-1, EP 220-2, EP 230-1, EP 230-2

Insert Processing holder prosthetic • Stainless

steel

Implant connection Article Number

NP 3,5 E 40

RP 4,3 E 41

Processing holder, prosthetics • fits

all inserts steel

• Stainless

Article Number

M 04

WP 5,0 E 42

D 6,0 E 43


The EV-Series abutments are compatible with

» EV-SERIES «

Dentsply® Implants ASTRA TECH OsseoSpeed® EV

DETAILANSICHT Genaue Ansicht der Abwinkelung (Indexierung) aller abgewinkelten Abutments.

Typ 1 abgewinkelt über Fläche

Typ 2 abgewinkelt über Nocke

Products indicated with ® are registered brand names of respective manufactures.


80

» EV-Series «

» EV-Series «

DENTSPLY Implants® ASTRA TECH OsseoSpeed EV®

Laboratory implant CADCAM • Stainless

DENTSPLY Implants® ASTRA TECH OsseoSpeed EV®

81

Titanium base Zirconium abutment 2nd Generation

steel

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection D 3,0 D 3,6 D 4,2 D 4,8 Article Number EV 80 EV 81 EV 82 EV 83 Please note: This is used for 3D printmodels with Scanbody 2. generation.

D 5,4 EV 84

Implant connection D 4,2 D 4,8 D 4,8 Chimney height 3.5 3.5 3.5 (mm) Gingiva height (mm) 1,15 0,65 1,15 Article Number EV 1220 EV 1030 EV 1230 Abutment screw EV 62 EV 63 EV 63 Laboratory screw EV 62 L EV 63 L EV 63 L Please note: This is used with Scanbody 2. generation.

Placement instrument laboratory implant CADCAM • Stainless

steel

D 3,0 EV 80 T

D 3,6 EV 81 T

D 4,2 EV 82 T

D 4,8 EV 83 T

D 5,4 EV 84 T

1.26

1,15 EV 1240 EV 63 EV 63 L

D 3,6 5.5

D 4,2 5.5

1,15 EV 1310 EV 61 EV 61 L

0,65 EV 1120 EV 62 EV 62 L

D 5,4 5.5

D 5,4 5.5

0,65 EV 1140 EV 63 EV 63 L

1,15 EV 1340 EV 63 EV 63 L

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection D 3,0 D 3,0 D 3,6 Chimney height 5.5 5.5 5.5 (mm) Gingiva height (mm) 0,65 1,15 0,65 Article Number EV 1100 EV 1300 EV 1110 Abutment screw EV 60 EV 60 EV 61 Laboratory screw EV 60 L EV 60 L EV 61 L Please note: This is used with Scanbody 2. generation.

grade 5 KV

Article Number

EV 60

EV 61

EV 62

EV 63

Laboratory screw • red

0,65 EV 1040 EV 63 EV 63 L

• Titanium

Abutment screw • Hex

D 5,4 3.5

Titanium base Zirconium abutment 2nd Generation Implant connection Article Number

• Titanium

D 5,4 3.5

Titanium base Zirconium abutment 2nd Generation

coated

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Article Number

EV 60 L

EV 61 L

EV 62 L

EV 63 L

Titanium base Zirconium abutment 2nd Generation

Implant connection D 4,2 D 4,8 D 4,8 Chimney height 5.5 5.5 5.5 (mm) Gingiva height (mm) 1,15 0,65 1,15 Article Number EV 1320 EV 1130 EV 1330 Abutment screw EV 62 EV 63 EV 63 Laboratory screw EV 62 L EV 63 L EV 63 L Please note: This is used with Scanbody 2. generation.

• Titanium

grade 5 KV • incl. abutment screw • Recommended torque: 25 Ncm Implant connection D 3,0 D 3,0 D 3,6 Chimney height 3.5 3.5 3.5 (mm) Gingiva height (mm) 0,65 1,15 0,65 Article Number EV 1000 EV 1200 EV 1010 Abutment screw EV 60 EV 60 EV 61 Laboratory screw EV 60 L EV 60 L EV 61 L Please note: This is used with Scanbody 2. generation.

D 3,6 3.5

D 4,2 3.5

1,15 EV 1210 EV 61 EV 61 L

0,65 EV 1020 EV 62 EV 62 L


82

» EV-Series «

» EV-Series «

DENTSPLY Implants® ASTRA TECH OsseoSpeed EV®

PreFace® abutment

MedentiCAD abutment

• Titanium

• Titanium

DENTSPLY Implants® ASTRA TECH OsseoSpeed EV®

83

grade 5 KV abutment screw • Recommended torque: 25 Ncm

grade 5 KV abutment screw • Recommended torque: 25 Ncm

• incl.

• incl.

Implant connection D 3,0 D 3,0 D 3,6 Diameter (mm) 11.5 16.0 11.5 Article Number EV 9000-R EV 9000-16R EV 9010-R Abutment screw EV 60 EV 60 EV 61 Laboratory screw EV 60 L EV 60 L EV 61 L Please note: This is used with Scanbody 2. generation.

D 3,6 16.0 EV 9010-16R EV 61 EV 61 L

D 4,2 11.5 EV 9020-R EV 62 EV 62 L

Implant connection D 3,0 D 3,6 D 4,2 D 4,8 Article Number EV 900001 EV 901001 EV 902001 EV 903001 Abutment screw EV 60 EV 61 EV 62 EV 63 Laboratory screw EV 60 L EV 61 L EV 62 L EV 63 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,4 EV 904001 EV 63 EV 63 L

Implant connection D 3,0 D 3,6 D 4,2 D 4,8 Article Number EV 900004 EV 901004 EV 902004 EV 903004 Abutment screw EV 60 EV 61 EV 62 EV 63 Laboratory screw EV 60 L EV 61 L EV 62 L EV 63 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,4 EV 904004 EV 63 EV 63 L

MedentiCAD abutment

PreFace® abutment

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 25 Ncm • incl.

• Titanium

grade 5 KV • incl. abutment screw • Recommended torque: 25 Ncm

Implant connection D 4,2 D 4,8 D 4,8 Diameter (mm) 16.0 11.5 16.0 Article Number EV 9020-16R EV 9030-R EV 9030-16R Abutment screw EV 62 EV 63 EV 63 Laboratory screw EV 62 L EV 63 L EV 63 L Please note: This is used with Scanbody 2. generation.

D 5,4 11.5 EV 9040-R EV 63 EV 63 L

D 5,4 16.0 EV 9040-16R EV 63 EV 63 L

Implant connection D 3,0 D 3,6 D 4,2 Diameter (mm) 11.5 16.0 16.0 Article Number EV 9800-R EV 9810-16R EV 9820-16R Abutment screw EV 60 EV 61 EV 62 Laboratory screw EV 60 L EV 61 L EV 62 L Please note: This is used with Scanbody 2. generation.

D 4,8 16.0 EV 9830-16R EV 63 EV 63 L

D 5,4 16.0 EV 9840-16R EV 63 EV 63 L

PreFace® abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 25 Ncm • incl.

Scanbody 2nd Generation • Titanium

grade 5 KV coated • incl. retention screw • specially

Implant connection D 3,0 D 3,6 D 4,2 D 4,8 Article Number EV 1400 EV 1410 EV 1420 EV 1430 Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 5,4 EV 1440


The F-Series abutments are compatible with

» F-SERIES «

Nobel Biocare® NobelActive® / NobelReplace® Conical

DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments.

Type 1

Type 2

angled over flat

angled over corner

Products indicated with ® are registered brand names of respective manufactures.


86

» F-Series «

Nobel Biocare® NobelActive - NobelReplace Conical®

» F-Series «

Implant pick-up Open tray

Abutment screw

• incl.

• Titanium

retention screw steel

• Stainless

• UG

Implant connection Version Article Number

NP 3,5 short F 10

RP 4,3/5,0 short F 11

Nobel Biocare® NobelActive - NobelReplace Conical®

grade 5 KV

Article Number

F 60

F 61

F 66

Article Number

F 60 L

F 61 L

F 66 L

Implant connection Article Number Abutment screw Laboratory screw

D 3,0 F 3520 F 66 F 66 L

NP 3,5 F 3500 F 60 F 60 L

RP 4,3/5,0 F 3510 F 61 F 61 L

Implant connection Article Number Abutment screw Laboratory screw

NP 3,5 F 3700 F 60 F 60 L

RP 4,3/5,0 F 3710 F 61 F 61 L

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

NP 3,5 1,5 4,5 F 100 F 60 F 60 L

RP 4,3/5,0 1,5 5,5 F 110 F 61 F 61 L

Laboratory screw • red

coated

Implant pick-up Open tray • incl.

retention screw steel

• Stainless

Temporary abutment • Titanium

Implant connection Version Article Number

NP 3,5 long F 20

RP 4,3/5,0 long F 21

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 35 Ncm: NP 3,5 35 Ncm: RP 4,3/5,0 • incl.

Laboratory implant • Stainless

steel

Implant connection Article Number

D 3,0 F 52

NP 3,5 F 50

RP 4,3/5,0 F 51

Temporary abutment rotating • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Laboratory implant CADCAM • Stainless

steel

Implant connection D 3,0 NP 3,5 Article Number F 82 F 80 Please note: This is used for 3D printmodels with Scanbody 2. generation.

RP 4,3/5,0 F 81

Standard abutment straight • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Placement instrument laboratory implant CADCAM • Stainless

steel

Implant connection Article Number

D 3,0 F 82 T

NP 3,5 F 80 T

RP 4,3/5,0 F 81 T

87


88

» F-Series «

Nobel Biocare® NobelActive - NobelReplace Conical®

» F-Series «

Standard abutment straight

Castable gold abutment rotating

• Titanium

• AU

grade 5 KV abutment screw • Recommended torque: 35 Ncm

Nobel Biocare® NobelActive - NobelReplace Conical®

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm

• incl.

• incl.

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

NP 3,5 3,0 4,5 F 100-3 F 60 F 60 L

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

RP 4,3/5,0 3,0 5,5 F 110-3 F 61 F 61 L

NP 3,5 0,28 F 300 R F 60 F 60 L

RP 4,3/5,0 0,37 F 310 R F 61 F 61 L

Solid abutment straight

Standard abutment angled 18°

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm • incl.

Type 1

Type 2

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

NP 3,5 1,5 4,5 F 200-1 F 200-2 F 60 F 60 L

Solid abutment angled 18°

Standard abutment angled 18°

• Titanium

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV • incl. abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm Type 1

Type 2

Implant connection NP 3,5 RP 4,3/5,0 Gingiva height (mm) 3,5 3,5 Diameter (mm) 5,0 5,5 Article Number F 400 F 410 Abutment screw F 60 F 61 Laboratory screw F 60 L F 61 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

RP 4,3/5,0 1,5 5,5 F 210-1 F 210-2 F 61 F 61 L

Type 1

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

NP 3,5 3,0 4,5 F 200-1-3 F 200-2-3 F 60 F 60 L

RP 4,3/5,0 3,0 5,5 F 210-1-3 F 210-2-3 F 61 F 61 L

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

NP 3,5 0,35 F 300 F 60 F 60 L

RP 4,3/5,0 0,44 F 310 F 61 F 61 L

Castable gold abutment • AU

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm • incl.

Type 2

Implant connection NP 3,5 RP 4,3/5,0 Gingiva height (mm) 3,5 3,5 Diameter (mm) 5,0 5,5 Article No. Type 1 F 500-1 F 510-1 Article No. Type 2 F 500-2 F 510-2 Abutment screw F 60 F 61 Laboratory screw F 60 L F 61 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

89


90

» F-Series «

Nobel Biocare® NobelActive - NobelReplace Conical®

POC abutment

» F-Series « Titanium base Zirconium abutment 1st Generation

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 Article Number F 900 Abutment screw F 60 Laboratory screw F 60 L Please note: For pressing on a individual ceramics Emergence profile.

RP 4,3/5,0 F 910 F 61 F 61 L

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: Just for use with 3M ESPE Lava™.

Pulse opaque • POC

Nobel Biocare® NobelActive - NobelReplace Conical®

NP 3,5 4,0

RP 4,3/5,0 4,0

0,8 F 800 LV F 60 F 60 L

0,8 F 810 LV F 61 F 61 L

NP 3,5 F 00 W

RP 4,3/5,0 F 10 W

RP 4,3/5,0 3.5

RP 4,3/5,0 3.5

0,65 F 1010 F 61 F 61 L

1,15 F 1210 F 61 F 61 L

abutment

Scanbody 1st Generation • Peek • incl.

Amount Article Number Please note:

retention screw

4 grams OP 90 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika. Implant connection Article Number Please note: This is used for Titanium base 1. generation.

Pulse press blank • POC

abutment

Colour Article Number Please note:

A3 B2 C2 D2 A2 P 90 P 91 P 92 P 93 P 94 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 1. generation.

NP 3,5 4,0

RP 4,3/5,0 4,0

0,8 F 800 F 60 F 60 L

0,8 F 810 F 61 F 61 L

Titanium base Zirconium abutment 2nd Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 35 Ncm: NP 3,5 35 Ncm: RP 4,3/5,0 • incl.

Implant connection D 3,0 NP 3,5 NP 3,5 Chimney height 3.5 3.5 3.5 (mm) Gingiva height (mm) 0,65 0,65 1,15 Article Number F 1020 F 1000 F 1200 Abutment screw F 66 F 60 F 60 Laboratory screw F 66 L F 60 L F 60 L Please note: This is used with Scanbody 2. generation.

91


92

» F-Series «

Nobel Biocare® NobelActive - NobelReplace Conical®

» F-Series «

Titanium base Zirconium abutment 2nd Generation

PreFace® abutment

• Titanium

• incl.

Nobel Biocare® NobelActive - NobelReplace Conical®

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 15 Ncm: D 3,0 35 Ncm: NP 3,5 35 Ncm: RP 4,3/5,0

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 35 Ncm: NP 3,5 35 Ncm: RP 4,3/5,0 • incl.

Implant connection D 3,0 NP 3,5 NP 3,5 Chimney height 5.5 5.5 5.5 (mm) Gingiva height (mm) 0,65 0,65 1,15 Article Number F 1120 F 1100 F 1300 Abutment screw F 66 F 60 F 60 Laboratory screw F 66 L F 60 L F 60 L Please note: This is used with Scanbody 2. generation.

RP 4,3/5,0 5.5

RP 4,3/5,0 5.5

0,65 F 1110 F 61 F 61 L

1,15 F 1310 F 61 F 61 L

Implant connection D 3,0 Diameter (mm) 11.5 Article Number F 9820-R Abutment screw F 66 Laboratory screw F 66 L Please note: This is used with Scanbody 2. generation.

NP 3,5 16.0 F 9800-16R F 60 F 60 L

RP 4,3/5,0 16.0 F 9810-16R F 61 F 61 L

Scanbody 2nd Generation Titanium base Bridges/ bars 2nd Generation

• Titanium

grade 5 KV coated • incl. retention screw • specially

• rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 35 Ncm: NP 3,5 35 Ncm: RP 4,3/5,0 • incl.

Implant connection D 3,0 Chimney height 3.5 (mm) Gingiva height (mm) 0,65 Article Number F 1520 Abutment screw F 66 Laboratory screw F 66 L Please note: This is used with Scanbody 2. generation.

NP 3,5 3.5

RP 4,3/5,0 3.5

0,65 F 1500 F 60 F 60 L

0,65 F 1510 F 61 F 61 L

PreFace® abutment

RP 4,3/5,0 F 901001 F 61 F 61 L

Implant connection D 3,0 NP 3,5 Article Number F 902004 F 900004 Abutment screw F 66 F 60 Laboratory screw F 66 L F 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

RP 4,3/5,0 F 901004 F 61 F 61 L

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 35 Ncm: NP 3,5 35 Ncm: RP 4,3/5,0 • incl.

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 35 Ncm: NP 3,5 35 Ncm: RP 4,3/5,0 RP 4,3/5,0 16.0 F 9010-16R F 61 F 61 L

Implant connection D 3,0 NP 3,5 Article Number F 902001 F 900001 Abutment screw F 66 F 60 Laboratory screw F 66 L F 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

• Titanium

• incl.

RP 4,3/5,0 11.5 F 9010-R F 61 F 61 L

RP 4,3/5,0 F 1410

MedentiCAD abutment

• Titanium

Implant connection D 3,0 NP 3,5 NP 3,5 Diameter (mm) 11.5 11.5 16.0 Article Number F 9020-R F 9000-R F 9000-16R Abutment screw F 66 F 60 F 60 Laboratory screw F 66 L F 60 L F 60 L Please note: This is used with Scanbody 2. generation.

Implant connection D 3,0 NP 3,5 Article Number F 1420 F 1400 Please note: The Scanbody is sterilisable and for intra-oral scanning.

MedentiCAD abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 15 Ncm: D 3,0 35 Ncm: NP 3,5 35 Ncm: RP 4,3/5,0 • incl.

93


94

» F-Series «

Nobel Biocare® NobelActive - NobelReplace Conical®

» F-Series «

MedentiCAD wax-up base

MedentiBASE scanbody

• Steel

• Titanium

• incl.

Nobel Biocare® NobelActive - NobelReplace Conical®

grade 5 KV specially coated • incl. bridge screw

abutment screw

Implant connection Article Number Please note: For use on the model only!

D 3,0 F 9120

NP 3,5 F 9100

Article Number Please note:

RP 4,3/5,0 F 9110

F 4900 The Scanbody is sterilisable and for intra-oral scanning.

MedentiBASE accessories • M

11-6 Placement instrument MedentiBASE abutment • F 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 35 Ncm

• Recommended

Implant connection Gingiva height (mm) Article Number

NP 3,5 0,5 F 4000

NP 3,5 1,5 F 4100

NP 3,5 2,5 F 4200

NP 3,5 3,5 F 4300

NP 3,5 4,5 F 4400

MedentiBASE abutment straight • Titanium

RP 4,3/5,0 1,5 F 4110

RP 4,3/5,0 2,5 F 4210

RP 4,3/5,0 3,5 F 4310

RP 4,3/5,0 4,5 F 4410

80

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capF 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

MedentiBASE prosthetic components

Implant connection NP 3,5 NP 3,5 NP 3,5 NP 3,5 NP 3,5 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number F 2000 F 2100 F 2200 F 2300 F 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• F

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

F 7600

F 4700

F 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" F 4720

Titanium grade 5 KV F 4840

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

MedentiBASE adhesive cap for passive-fit 4800 MedentiBASE adhesive cap Short incl. bridge screw • F 4810 MedentiBASE adhesive casing Short • F 4820 MedentiBASE adhesive cap Long incl. bridge screw • F 4830 MedentiBASE adhesive casing Long

M 11-6

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head

grade 5 KV torque: 35 Ncm

RP 4,3/5,0 0,5 F 4010

4630

• M

Article Number Please note:

Implant connection Gingiva height (mm) Article Number

F 4620

MedentiBASE finisher

• Recommended

7600 MedentiBASE bridge screw UG • F 4700 MedentiBASE titanium cap incl. bridge screw • F 4710 MedentiBASE plastic cap incl. bridge screw • F 4720 MedentiBASE gold cap, castable incl. bridge screw • F 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

Article Number

Implant connection RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number F 2010 F 2110 F 2210 F 2310 F 2410 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• F

Version Article Number

Short F 4800

Short F 4810

Long F 4820

Long F 4830

95


96

» F-Series «

Nobel Biocare® NobelActive - NobelReplace Conical®

» F-Series «

MedentiLOC abutment angled 15°

MedentiLOC Laboratory implant

• Titanium

• Stainless

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 35 Ncm • titanium

Type 1

Implant connection NP 3,5 NP 3,5 NP 3,5 NP 3,5 NP 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number F 2500-1 F 2600-1 F 2700-1 F 2800-1 F 2900-1 Abutment screw F 64 F 64 F 64 F 64 F 64 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

• Ball

• Titanium

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 35 Ncm

Hex

Implant connection RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number F 2510-1 F 2610-1 F 2710-1 F 2810-1 F 2910-1 Abutment screw F 65 F 65 F 65 F 65 F 65 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

F 64

F 65

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

Implant connection NP 3,5 NP 3,5 NP 3,5 NP 3,5 NP 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number F 6000 F 6100 F 6200 F 6300 F 6400 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

• Titanium

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

Material Matrix housing Article Number Please note:

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Implant connection RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number F 6010 F 6110 F 6210 F 6310 F 6410 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Placement instrument MedentiLOC abutment, angled Hex

Article Number

Novaloc abutment straight

• Retention

• Ball

angled 57

• Titanium

• Matrix

• Hardened

straight 56

grade 5 KV

Novaloc Processing package housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

Version Article Number

Novaloc abutment straight

• titanium

Type 1

steel

Abutment screw MedentiLOC abutment, angled • Titanium

MedentiLOC abutment angled 15°

Nobel Biocare® NobelActive - NobelReplace Conical®

Novaloc abutment angled 15°

stainless steel Version Article Number

Contra-angle M 03-7

Manual and ratchet M 10-7

• Titanium

grade 5 KV coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 35 Ncm • LTC

Type 1

Implant connection NP 3,5 NP 3,5 NP 3,5 NP 3,5 NP 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number F 6500-1 F 6600-1 F 6700-1 F 6800-1 F 6900-1 Abutment screw F 67 F 67 F 67 F 67 F 67 Please note: To screw in the angled Novaloc abutments you need the special Placement instrument Ball-Torx M 03-8 or M 10-8.

97


98

» F-Series «

Nobel Biocare® NobelActive - NobelReplace Conical®

» F-Series «

Novaloc abutment angled 15°

Optiloc abutment straight

• Titanium

• LTC

• Titanium

grade 5 KV coated • Recommended torque: 35 Ncm

grade 5 KV coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 35 Ncm • LTC

Type 1

Implant connection NP 3,5 NP 3,5 NP 3,5 NP 3,5 NP 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number F 5000 F 5100 F 5200 F 5300 F 5400 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Implant connection RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number F 6510-1 F 6610-1 F 6710-1 F 6810-1 F 6910-1 Abutment screw F 68 F 68 F 68 F 68 F 68 Please note: To screw in the angled Novaloc abutments you need the special Placement instrument Ball-Torx M 03-8 or M 10-8.

Optiloc abutment straight

Novaloc Processing package housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

Nobel Biocare® NobelActive - NobelReplace Conical®

• Titanium

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

• Matrix

• Retention

Material Matrix housing Article Number Please note:

Titanium

Implant connection RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 RP 4,3/5,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number F 5010 F 5110 F 5210 F 5310 F 5410 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument Novaloc abutment, angled

Optiloc Processing package

• Hardened

• Matrix

• Ball

stainless steel Torx®

housing, titanium insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • Retention

Version Article Number

Contra-angle M 03-8

Manual and ratchet M 10-8

Novaloc Laboratory implant • Stainless

Material Matrix housing Article Number Please note:

5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument Optiloc abutment

steel

Version Article Number

straight 58

angled 59

• Hardened

stainless steel

Version

Abutment screw Novaloc abutment, angled

Article Number

• Titanium • Ball

Titanium

grade 5 KV Torx®

Manual and ratchet M 59

Optiloc implant analogue • Aluminium

Article Number

F 67

F 68

Version Article Number

4 piece 2102.0024

99


100

» F-Series «

Nobel Biocare® NobelActive - NobelReplace Conical®

Planning abutment straight • Aluminium

red coated

Implant connection Gingiva height (mm) Diameter (mm) Article Number

NP 3,5 1,5/3,0 4,5 FP 100-3

RP 4,3/5,0 1,5/3,0 5,5 FP 110-3

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2

NP 3,5 1,5/3,0 4,5 FP 200-1-3 FP 200-2-3

RP 4,3/5,0 1,5/3,0 5,5 FP 210-1-3 FP 210-2-3

Planning abutment angled 18° • Aluminium

red coated 1 = angled over flat • Type 2 = angled over corner • Type

Type 1

Type 2

Planning abutment set • 6

piece

Article Number Content:

FPS FP 100-3, FP 110-3, FP 200-1-3, FP 200-2-3, FP 210-1-3, FP 210-2-3

Insert Processing holder prosthetic • Stainless

steel

Implant connection Article Number

D 3,0 F 42

Article Number

M 04

Processing holder, prosthetics • fits

all inserts steel

• Stainless

NP 3,5 F 40

RP 4,3/5,0 F 41


The H-Series abutments are compatible with

» H-SERIES «

BIOMET 3i® Certain®

DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments.

Type 1

Type 2

angled over flat

angled over corner

Products indicated with ® are registered brand names of respective manufactures.


104

» H-Series «

» H-Series «

BIOMET 3i® Certain®

Laboratory implant

Temporary abutment

• Stainless

• Titanium

steel

105

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection Article Number

D 3,4 H 50

D 4,1 H 51

D 5,0 H 52

Laboratory implant CADCAM • Stainless

BIOMET 3i® Certain®

Implant connection Article Number Abutment screw Laboratory screw

D 3,4 H 3500 H 60 H 60 L

D 4,1 H 3510 H 60 H 60 L

Temporary abutment rotating

steel

• Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection D 3,4 D 4,1 Article Number H 80 H 81 Please note: This is used for 3D printmodels with Scanbody 2. generation.

D 5,0 H 82

Placement instrument laboratory implant CADCAM • Stainless

Implant connection Article Number Abutment screw Laboratory screw

D 3,4 H 3700 H 60 H 60 L

D 4,1 H 3710 H 60 H 60 L

D 5,0 H 3720 H 60 H 60 L

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

D 3,4 1,5 4,2 H 100 H 60 H 60 L

D 4,1 1,5 4,7 H 110 H 60 H 60 L

D 5,0 1,5 5,9 H 120 H 60 H 60 L

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

D 3,4 3,0 4,5 H 100-3 H 60 H 60 L

D 4,1 3,0 5,2 H 110-3 H 60 H 60 L

D 5,0 3,0 6,2 H 120-3 H 60 H 60 L

Standard abutment straight

steel

• Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection Article Number

D 3,4 H 80 T

D 4,1 H 81 T

D 5,0 H 82 T

Abutment screw • Titanium • Hex

1.2

grade 5 KV

Article Number

H 60

Laboratory screw • red

Standard abutment straight • Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

coated

Article Number

H 60 L


106

» H-Series «

» H-Series «

BIOMET 3i® Certain®

Standard abutment angled 18°

Solid abutment straight

• Titanium

• incl.

grade 5 KV abutment screw • Recommended torque: 20 Ncm

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 20 Ncm Type 2

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

D 3,4 1,5 4,2 H 200-1 H 200-2 H 60 H 60 L

D 4,1 1,5 4,7 H 210-1 H 210-2 H 60 H 60 L

D 5,0 1,5 5,7 H 220-1 H 220-2 H 60 H 60 L

Standard abutment angled 18°

Solid abutment angled 18°

• Titanium

• Titanium

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 20 Ncm Type 2

Implant connection D 3,4 D 4,1 Gingiva height (mm) 3,5 3,5 Diameter (mm) 4,7 5,4 Article Number H 400 H 410 Abutment screw H 60 H 60 Laboratory screw H 60 L H 60 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

D 5,0 3,5 6,5 H 420 H 60 H 60 L

Implant connection D 3,4 D 4,1 Gingiva height (mm) 3,5 3,5 Diameter (mm) 4,7 5,4 Article No. Type 1 H 500-1 H 510-1 Article No. Type 2 H 500-2 H 510-2 Abutment screw H 60 H 60 Laboratory screw H 60 L H 60 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

D 5,0 3,5 6,5 H 520-1 H 520-2 H 60 H 60 L

Implant connection D 3,4 D 4,1 Article Number H 900 H 910 Abutment screw H 60 H 60 Laboratory screw H 60 L H 60 L Please note: For pressing on a individual ceramics Emergence profile.

D 5,0 H 920 H 60 H 60 L

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 20 Ncm

• incl.

Type 1

107

• Titanium

• incl.

Type 1

BIOMET 3i® Certain®

• incl.

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

D 3,4 3,0 4,5 H 200-1-3 H 200-2-3 H 60 H 60 L

D 4,1 3,0 5,2 H 210-1-3 H 210-2-3 H 60 H 60 L

D 5,0 3,0 6,2 H 220-1-3 H 220-2-3 H 60 H 60 L

Type 1

Type 2

Castable gold abutment • AU

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 20 Ncm

POC abutment

• incl.

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

D 3,4 0,43 H 300 H 60 H 60 L

D 4,1 0,63 H 310 H 60 H 60 L

D 5,0 0,88 H 320 H 60 H 60 L

Castable gold abutment rotating

Pulse opaque

• AU

60%; Pd 20%; Pt 19%; Ir 1% • incl. abutment screw • Recommended torque: 20 Ncm

• POC

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

D 3,4 0,35 H 300 R H 60 H 60 L

D 4,1 0,54 H 310 R H 60 H 60 L

D 5,0 0,79 H 320 R H 60 H 60 L

abutment

Amount Article Number Please note:

4 grams OP 90 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.


108

» H-Series «

» H-Series «

BIOMET 3i® Certain®

Pulse press blank • POC

BIOMET 3i® Certain®

109

Titanium base Zirconium abutment 2nd Generation

abutment

• Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Colour Article Number Please note:

A3 B2 C2 D2 A2 P 90 P 91 P 92 P 93 P 94 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Implant connection D 3,4 Chimney height 3.5 (mm) Gingiva height (mm) 0,3 Article Number H 1000 Abutment screw H 60 Laboratory screw H 60 L Please note: This is used with Scanbody 2. generation.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm

D 4,1 3.5

D 5,0 3.5

0,3 H 1010 H 60 H 60 L

0,3 H 1020 H 60 H 60 L

D 4,1 5.5

D 5,0 5.5

0,3 H 1110 H 60 H 60 L

0,3 H 1120 H 60 H 60 L

D 4,1 3.5

D 5,0 3.5

0,3 H 1510 H 60 H 60 L

0,3 H 1520 H 60 H 60 L

• incl.

Titanium base Zirconium abutment 2nd Generation Implant connection D 3,4 Chimney height 4,0 (mm) Gingiva height (mm) 0,3 Article Number H 800 Abutment screw H 60 H 60 L Laboratory screw Please note: This is used with Scanbody 1. generation.

D 4,1 4,0

D 5,0 4,0

0,3 H 810 H 60 H 60 L

0,3 H 820 H 60 H 60 L

• Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection D 3,4 Chimney height 5.5 (mm) Gingiva height (mm) 0,3 Article Number H 1100 Abutment screw H 60 Laboratory screw H 60 L Please note: This is used with Scanbody 2. generation.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Titanium base Bridges/ bars 2nd Generation Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: Just for use with 3M ESPE Lava™.

D 3,4 4,0 0,3 H 800 LV H 60 H 60 L

D 4,1 4,0 0,3 H 810 LV H 60 H 60 L

D 5,0 4,0 0,3 H 820 LV H 60 H 60 L

Scanbody 1 Generation st

• Peek • incl.

retention screw

Implant connection Article Number Please note: This is used for Titanium base 1. generation.

D 3,4 H 00 W

D 4,1/5,0 H 10 W

• rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection D 3,4 Chimney height 3.5 (mm) Gingiva height (mm) 0,3 Article Number H 1500 Abutment screw H 60 Laboratory screw H 60 L Please note: This is used with Scanbody 2. generation.


110

» H-Series «

» H-Series «

BIOMET 3i® Certain®

PreFace® abutment

MedentiCAD abutment

• Titanium

• CrCo

BIOMET 3i® Certain®

111

alloy / CTE 14.1 abutment screw • Recommended torque: 20 Ncm

grade 5 KV abutment screw • Recommended torque: 20 Ncm

• incl.

• incl.

Implant connection D 3,4 D 4,1 Diameter (mm) 11.5 11.5 Article Number H 9000-R H 9010-R Abutment screw H 60 H 60 Laboratory screw H 60 L H 60 L Please note: This is used with Scanbody 2. generation.

D 4,1 16.0 H 9010-16R H 60 H 60 L

Implant connection D 3,4 D 4,1 Article Number H 900004 H 901004 Abutment screw H 60 H 60 Laboratory screw H 60 L H 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,0 16.0 H 9020-16R H 60 H 60 L

D 5,0 H 902004 H 60 H 60 L

MedentiCAD wax-up base

PreFace® abutment

• Steel • incl.

• CrCo

alloy / CTE 14.1 • incl. abutment screw • Recommended torque: 20 Ncm

Implant connection D 3,4 Diameter (mm) 11.5 Article Number H 9800-R Abutment screw H 60 Laboratory screw H 60 L Please note: This is used with Scanbody 2. generation.

D 4,1 16.0 H 9810-16R H 60 H 60 L

D 5,0 16.0 H 9820-16R H 60 H 60 L

abutment screw

Implant connection Article Number Please note: For use on the model only!

D 3,4 H 9100

D 4,1 H 9110

D 5,0 H 9120

Implant connection Gingiva height (mm) Article Number

D 3,4 0,5 H 4000

D 3,4 1,5 H 4100

D 3,4 2,5 H 4200

D 3,4 3,5 H 4300

D 3,4 4,5 H 4400

Implant connection Gingiva height (mm) Article Number

D 4,1 0,5 H 4010

D 4,1 1,5 H 4110

D 4,1 2,5 H 4210

D 4,1 3,5 H 4310

D 4,1 4,5 H 4410

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 20 Ncm

• Recommended

Scanbody 2 Generation nd

• Titanium

grade 5 KV coated • incl. retention screw • specially

Implant connection D 3,4 Article Number H 1400 Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 4,1/5,0 H 1410

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 20 Ncm

• Recommended

MedentiCAD abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 20 Ncm • incl.

Implant connection D 3,4 D 4,1 Article Number H 900001 H 901001 Abutment screw H 60 H 60 Laboratory screw H 60 L H 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,0 H 902001 H 60 H 60 L


112

» H-Series «

» H-Series «

BIOMET 3i® Certain®

MedentiBASE prosthetic components

MedentiLOC abutment straight

• H

• Titanium

7600 MedentiBASE bridge screw Hex 1.2 • H 4700 MedentiBASE titanium cap incl. bridge screw • H 4710 MedentiBASE plastic cap incl. bridge screw • H 4720 MedentiBASE gold cap, castable incl. bridge screw • H 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

113

grade 5 KV nitride coated • Recommended torque: 20 Ncm • titanium

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

H 7600

H 4700

H 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" H 4720

Titanium grade 5 KV Implant connection D 3,4 D 3,4 D 3,4 D 3,4 D 3,4 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number H 2000 H 2100 H 2200 H 2300 H 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

H 4840

MedentiBASE adhesive cap for passive-fit 4800 MedentiBASE adhesive cap Short incl. bridge screw • H 4810 MedentiBASE adhesive casing Short • H 4820 MedentiBASE adhesive cap Long incl. bridge screw • H 4830 MedentiBASE adhesive casing Long

BIOMET 3i® Certain®

MedentiLOC abutment straight

• H

• Titanium

grade 5 KV nitride coated • Recommended torque: 20 Ncm • titanium

Version Article Number

Short H 4800

Short H 4810

Long H 4820

Long H 4830 Implant connection D 4,1 D 4,1 D 4,1 D 4,1 D 4,1 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number H 2010 H 2110 H 2210 H 2310 H 2410 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

MedentiBASE scanbody • Titanium

grade 5 KV specially coated • incl. bridge screw

MedentiLOC abutment straight Article Number Please note:

H 4900 The Scanbody is sterilisable and for intra-oral scanning.

• Titanium

grade 5 KV nitride coated • Recommended torque: 20 Ncm • titanium

MedentiBASE accessories 11-6 Placement instrument MedentiBASE abutment • H 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

Implant connection D 5,0 D 5,0 D 5,0 D 5,0 D 5,0 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number H 2020 H 2120 H 2220 H 2320 H 2420 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• M

Article Number

H 4620

4630

M 11-6

80

Novaloc Processing package

MedentiBASE finisher

• Matrix

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert • Retention

• M

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head Article Number Please note:

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capH 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

Material Matrix housing Article Number Please note:

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.


114

» H-Series «

» H-Series «

BIOMET 3i® Certain®

MedentiLOC Laboratory implant

Optiloc abutment straight

• Stainless

• LTC

BIOMET 3i® Certain®

115

• Titanium

grade 5 KV coated • Recommended torque: 20 Ncm

steel

Version Article Number

straight 56

Implant connection D 3,4 D 3,4 D 3,4 D 3,4 D 3,4 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number H 5000 H 5100 H 5200 H 5300 H 5400 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Novaloc abutment straight • Titanium

grade 5 KV coated • Recommended torque: 20 Ncm • LTC

Optiloc abutment straight • Titanium

grade 5 KV coated • Recommended torque: 20 Ncm • LTC

Implant connection D 3,4 D 3,4 D 3,4 D 3,4 D 3,4 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number H 6000 H 6100 H 6200 H 6300 H 6400 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Implant connection D 4,1 D 4,1 D 4,1 D 4,1 D 4,1 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number H 5010 H 5110 H 5210 H 5310 H 5410 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Novaloc abutment straight • Titanium

grade 5 KV coated • Recommended torque: 20 Ncm • LTC

Optiloc Processing package Implant connection D 4,1 D 4,1 D 4,1 D 4,1 D 4,1 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number H 6010 H 6110 H 6210 H 6310 H 6410 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Novaloc Processing package • Matrix

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

housing, titanium insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • Retention

Material Matrix housing Article Number Please note:

Titanium 5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument Optiloc abutment

• Retention

• Hardened

Material Matrix housing Article Number Please note:

Titanium

stainless steel

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Version Article Number

Novaloc Laboratory implant • Stainless

• Matrix

Manual and ratchet M 59

Optiloc implant analogue • Aluminium

steel

Version Article Number

straight 58

Version Article Number

4 piece 2102.0024


116

» H-Series «

BIOMET 3i® Certain®

Planning abutment straight • Aluminium

red coated

Implant connection Gingiva height (mm) Diameter (mm) Article Number

D 3,4 1,5/3,0 4,5 HP 100-3

D 4,1 1,5/3,0 5,2 HP 110-3

D 5,0 1,5/3,0 6,2 HP 120-3

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2

D 3,4 1,5/3,0 4,5 HP 200-1-3 HP 200-2-3

D 4,1 1,5/3,0 5,2 HP 210-1-3 HP 210-2-3

D 5,0 1,5/3,0 6,2 HP 220-1-3 HP 220-2-3

Planning abutment angled 18° • Aluminium

red coated 1 = angled over flat • Type 2 = angled over corner • Type

Type 1

Type 2

Planning abutment set • 9

piece

Article Number Content:

HPS HP 100-3, HP 110-3, HP 120-3, HP 200-1-3, HP 200-2-3, HP 210-1-3, HP 210-2-3, HP 220-1-3, HP 220-2-3

Insert Processing holder prosthetic • Stainless

steel

Implant connection Article Number

D 3,4 H 40

Article Number

M 04

Processing holder, prosthetics • fits

all inserts steel

• Stainless

D 4,1 H 41

D 5,0 H 42


The I-Series abutments are compatible with

» I-SERIES «

BIOMET 3i® External Hex

DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments.

Type 1

Type 2

angled over flat

angled over corner

Products indicated with ® are registered brand names of respective manufactures.


120

» I-Series «

» I-Series «

BIOMET 3i® External Hex

Laboratory implant

Temporary abutment

• Stainless

• Titanium

steel

121

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection Article Number

D 3,4 I 50

D 4,1 I 51

D 5,0 I 52

Laboratory implant CADCAM • Stainless

BIOMET 3i® External Hex

Implant connection Article Number Abutment screw Laboratory screw

D 3,4 I 3500 I 61 I 61 L

D 4,1 I 3510 I 61 I 61 L

Standard abutment straight

steel

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection D 3,4 D 4,1 Article Number I 80 I 81 Please note: This is used for 3D printmodels with Scanbody 2. generation.

D 5,0 I 82

Placement instrument laboratory implant CADCAM • Stainless

steel

D 3,4-5,0 I 80 T

Abutment screw • Hex

1.26

D 4,1 2,5 4,8 I 110 I 61 I 61 L

D 5,0 2,5 6,5 I 120 I 61 I 61 L

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

D 3,4 2,5 4,4 I 200-1 I 200-2 I 61 I 61 L

D 4,1 2,5 4,8 I 210-1 I 210-2 I 61 I 61 L

D 5,0 2,5 6,5 I 220-1 I 220-2 I 61 I 61 L

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

D 3,4 0,37 I 300 I 61 I 61 L

D 4,1 0,57 I 310 I 61 I 61 L

D 5,0 0,97 I 320 I 61 I 61 L

• Titanium

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm • incl.

Type 1

grade 5 KV

Type 2

Article Number

I 61

Laboratory screw • red

D 3,4 2,5 4,4 I 100 I 61 I 61 L

Standard abutment angled 16° Implant connection Article Number

• Titanium

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

Castable gold abutment

coated

• AU

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm • incl.

Article Number

I 61 L


122

» I-Series «

» I-Series «

BIOMET 3i® External Hex

Castable gold abutment rotating

Titanium base Zirconium abutment 1st Generation

• AU

• Titanium

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm

BIOMET 3i® External Hex

123

grade 5 KV abutment screw • Recommended torque: 35 Ncm

• incl.

• incl.

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

D 4,1 0,57 I 310 R I 61 I 61 L

Implant connection D 3,4 Chimney height 4,0 (mm) Gingiva height (mm) 0,6 Article Number I 800 Abutment screw I 61 Laboratory screw I 61 L Please note: This is used with Scanbody 1. generation.

POC abutment alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm

D 4,1 4,0

D 5,0 4,0

0,5 I 810 I 61 I 61 L

0,6 I 820 I 61 I 61 L

D 3,4 4,0

D 4,1 4,0

D 5,0 4,0

0,6 I 800 LV I 61 I 61 L

0,5 I 810 LV I 61 I 61 L

0,6 I 820 LV I 61 I 61 L

D 3,4 I 00 W

D 4,1/5,0 I 10 W

• CrCo • incl.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection D 3,4 D 4,1 Article Number I 900 I 910 Abutment screw I 61 I 61 Laboratory screw I 61 L I 61 L Please note: For pressing on a individual ceramics Emergence profile.

D 5,0 I 920 I 61 I 61 L

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: Just for use with 3M ESPE Lava™.

Pulse opaque • POC

abutment

Amount Article Number Please note:

4 grams OP 90 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Scanbody 1st Generation • Peek • incl.

retention screw

Pulse press blank • POC

abutment

Implant connection Article Number Please note: This is used for Titanium base 1. generation. Colour Article Number Please note:

A3 B2 C2 D2 A2 P 90 P 91 P 92 P 93 P 94 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.


124

» I-Series «

» I-Series «

BIOMET 3i® External Hex

Titanium base Zirconium abutment 2nd Generation

BIOMET 3i® External Hex

125

PreFace® abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection D 3,4 Chimney height 3.5 (mm) Gingiva height (mm) 0,6 Article Number I 1000 Abutment screw I 61 Laboratory screw I 61 L Please note: This is used with Scanbody 2. generation.

D 4,1 3.5

D 5,0 3.5

0,6 I 1010 I 61 I 61 L

0,6 I 1020 I 61 I 61 L

Implant connection D 3,4 Diameter (mm) 11.5 Article Number I 9000-R Abutment screw I 61 Laboratory screw I 61 L Please note: This is used with Scanbody 2. generation.

D 4,1 11.5 I 9010-R I 61 I 61 L

D 5,0 16.0 I 9020-16R I 61 I 61 L

Implant connection D 3,4 Diameter (mm) 11.5 Article Number I 9800-R Abutment screw I 61 Laboratory screw I 61 L Please note: This is used with Scanbody 2. generation.

D 4,1 11.5 I 9810-R I 61 I 61 L

D 5,0 16.0 I 9820-16R I 61 I 61 L

PreFace® abutment Titanium base Zirconium abutment 2nd Generation

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection D 3,4 Chimney height 5.5 (mm) Gingiva height (mm) 0,6 Article Number I 1100 Abutment screw I 61 Laboratory screw I 61 L Please note: This is used with Scanbody 2. generation.

D 4,1 5.5

D 5,0 5.5

0,6 I 1110 I 61 I 61 L

0,6 I 1120 I 61 I 61 L

Scanbody 2nd Generation • Titanium

grade 5 KV coated • incl. retention screw • specially

Titanium base Bridges/ bars 2nd Generation • rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection D 3,4 Chimney height 3.5 (mm) Gingiva height (mm) 0,6 Article Number I 1500 Abutment screw I 61 Laboratory screw I 61 L Please note: This is used with Scanbody 2. generation.

D 4,1 3.5

D 5,0 3.5

0,6 I 1510 I 61 I 61 L

0,6 I 1520 I 61 I 61 L

Implant connection D 3,4 Article Number I 1400 Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 4,1/5,0 I 1410

Implant connection D 3,4 D 4,1 Article Number I 900001 I 901001 Abutment screw I 61 I 61 Laboratory screw I 61 L I 61 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,0 I 902001 I 61 I 61 L

MedentiCAD abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.


126

» I-Series «

» I-Series «

BIOMET 3i® External Hex

MedentiCAD abutment

127

MedentiBASE prosthetic components

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.

• I

Implant connection D 3,4 D 4,1 Article Number I 900004 I 901004 Abutment screw I 61 I 61 Laboratory screw I 61 L I 61 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,0 I 902004 I 61 I 61 L

7600 MedentiBASE bridge screw Hex 1.26 • I 4700 MedentiBASE titanium cap incl. bridge screw • I 4710 MedentiBASE plastic cap incl. bridge screw • I 4720 MedentiBASE gold cap, castable incl. bridge screw • I 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

Titanium grade 5 KV

I 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" I 4720

I 7600

I 4700

Short I 4800

Short I 4810

Long I 4820

Long I 4830

I 4840

MedentiBASE adhesive cap for passive-fit

MedentiCAD wax-up base • Steel • incl.

BIOMET 3i® External Hex

• I

abutment screw

Implant connection Article Number Please note: For use on the model only!

D 3,4 I 9100

D 4,1 I 9110

D 5,0 I 9120

4800 MedentiBASE adhesive cap Short incl. bridge screw • I 4810 MedentiBASE adhesive casing Short • I 4820 MedentiBASE adhesive cap Long incl. bridge screw • I 4830 MedentiBASE adhesive casing Long

Version Article Number

MedentiBASE scanbody MedentiBASE abutment straight • Titanium

• Titanium

grade 5 KV specially coated • incl. bridge screw

grade 5 KV torque: 35 Ncm

• Recommended

Article Number Please note: Implant connection Gingiva height (mm) Article Number

D 3,4 2,5 I 4000

D 3,4 3,5 I 4100

D 3,4 4,5 I 4200

MedentiBASE abutment straight • Titanium

grade 5 KV • Recommended torque: 35 Ncm

I 4900 The Scanbody is sterilisable and for intra-oral scanning.

MedentiBASE accessories • M

11-6 Placement instrument MedentiBASE abutment • I 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

Article Number

I 4620

4630

M 11-6

80

MedentiBASE finisher Implant connection Gingiva height (mm) Article Number

D 4,1 2,5 I 4010

D 4,1 3,5 I 4110

D 4,1 4,5 I 4210

• M

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head Article Number Please note:

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capI 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.


128

» I-Series «

» I-Series «

BIOMET 3i® External Hex

MedentiLOC abutment straight

MedentiLOC Laboratory implant

• Titanium

• Stainless

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

Implant connection D 3,4 D 3,4 D 3,4 D 3,4 D 3,4 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number I 2000 I 2100 I 2200 I 2300 I 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

BIOMET 3i® External Hex

129

steel

Version Article Number

straight 56

Planning abutment straight • Aluminium

red coated

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

Implant connection D 4,1 D 4,1 D 4,1 D 4,1 D 4,1 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number I 2010 I 2110 I 2210 I 2310 I 2410 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

Implant connection Gingiva height (mm) Diameter (mm) Article Number

D 4,1 2,5 4,8 IP 110

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2

D 4,1 2,5 4,8 IP 210-1 IP 210-2

Planning abutment angled 18° • Aluminium

red coated 1 = angled over flat • Type 2 = angled over corner • Type

MedentiLOC abutment straight

Type 1

Type 2

• Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm

• titanium

Implant connection D 5,0 D 5,0 D 5,0 D 5,0 D 5,0 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number I 2020 I 2120 I 2220 I 2320 I 2420 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

Planning abutment set • 3

piece

Novaloc Processing package housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

Article Number Content:

• Matrix

IPS IP 110, IP 210-1, IP 210-2

• Retention

Insert Processing holder prosthetic Material Matrix housing Article Number Please note:

Titanium

Peek

• Stainless

steel

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®. Implant connection Article Number

D 3,4 I 40

D 4,1 I 41

D 5,0 I 42


130

» I-Series «

BIOMET 3i® External Hex

Processing holder, prosthetics • fits

all inserts steel

• Stainless

Article Number

M 04


The K-Series abutments are compatible with

» K-SERIES «

Nobel Biocare® Brånemark®

DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments.

Type 1

Type 2

angled over flat

angled over corner

Products indicated with ® are registered brand names of respective manufactures.


134

» K-Series «

» K-Series «

Nobel Biocare® Brånemark®

Laboratory implant

Temporary abutment

• Stainless

• Titanium

steel

135

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection Article Number

NP 3,5 K 50

RP 4,1 K 51

WP 5,1 K 52

Laboratory implant CADCAM • Stainless

Nobel Biocare® Brånemark®

Implant connection Article Number Abutment screw Laboratory screw

NP 3,5 K 3500 K 60 K 60 L

RP 4,1 K 3510 K 61 K 61 L

Standard abutment straight

steel

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 RP 4,1 Article Number K 80 K 81 Please note: This is used for 3D printmodels with Scanbody 2. generation.

WP 5,1 K 82

Placement instrument laboratory implant CADCAM • Stainless

steel

NP 3,5 K 80 T

RP 4,1 K 81 T

WP 5,1 K 82 T

Abutment screw • UG

RP 4,1 2,5 4,8 K 110 K 61 K 61 L

WP 5,1 2,5 6,5 K 120 K 62 K 62 L

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

NP 3,5 2,5 4,4 K 200-1 K 200-2 K 60 K 60 L

RP 4,1 2,5 4,8 K 210-1 K 210-2 K 61 K 61 L

WP 5,1 2,5 6,5 K 220-1 K 220-2 K 62 K 62 L

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

NP 3,5 0,45 K 300 K 60 K 60 L

RP 4,1 0,57 K 310 K 61 K 61 L

WP 5,1 0,80 K 320 K 62 K 62 L

• Titanium

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm • incl.

Type 1

grade 5 KV

Type 2

Article Number

K 60

K 61

K 62

Laboratory screw • red

NP 3,5 2,5 4,4 K 100 K 60 K 60 L

Standard abutment angled 16° Implant connection Article Number

• Titanium

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

Castable gold abutment

coated

• AU

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm • incl.

Article Number

K 60 L

K 61 L

K 62 L


136

» K-Series «

» K-Series «

Nobel Biocare® Brånemark®

Castable gold abutment rotating

Titanium base Zirconium abutment 1st Generation

• AU

• Titanium

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm

Nobel Biocare® Brånemark®

137

grade 5 KV abutment screw • Recommended torque: 35 Ncm

• incl.

• incl.

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

RP 4,1 0,57 K 310 R K 61 K 61 L

POC abutment alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm

Implant connection NP 3,5 Chimney height 4,0 (mm) Gingiva height (mm) 0,6 Article Number K 800 Abutment screw K 60 Laboratory screw K 60 L Please note: This is used with Scanbody 1. generation.

RP 4,1 4,0

WP 5,1 4,0

0,5 K 810 K 61 K 61 L

0,6 K 820 K 62 K 62 L

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: Just for use with 3M ESPE Lava™.

NP 3,5 4,0

RP 4,1 4,0

WP 5,1 4,0

0,6 K 800 LV K 60 K 60 L

0,5 K 810 LV K 61 K 61 L

0,6 K 820 LV K 62 K 62 L

RP 4,1 K 10 W

WP 5,1 K 20 W

• CrCo • incl.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 RP 4,1 Article Number K 900 K 910 Abutment screw K 60 K 61 Laboratory screw K 60 L K 61 L Please note: For pressing on a individual ceramics Emergence profile.

WP 5,1 K 920 K 62 K 62 L

Pulse opaque • POC

abutment

Amount Article Number Please note:

4 grams OP 90 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Scanbody 1st Generation • Peek • incl.

retention screw

Pulse press blank • POC

abutment

Implant connection NP 3,5 Article Number K 00 W Please note: This is used for Titanium base 1. generation. Colour Article Number Please note:

A3 B2 C2 D2 A2 P 90 P 91 P 92 P 93 P 94 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.


138

» K-Series «

» K-Series «

Nobel Biocare® Brånemark®

Titanium base Zirconium abutment 2nd Generation

Nobel Biocare® Brånemark®

139

PreFace® abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 Chimney height 3.5 (mm) Gingiva height (mm) 0,6 Article Number K 1000 Abutment screw K 60 Laboratory screw K 60 L Please note: This is used with Scanbody 2. generation.

RP 4,1 3.5

WP 5,1 3.5

0,6 K 1010 K 61 K 61 L

0,6 K 1020 K 62 K 62 L

Implant connection NP 3,5 Diameter (mm) 11.5 Article Number K 9000-R Abutment screw K 60 Laboratory screw K 60 L Please note: This is used with Scanbody 2. generation.

RP 4,1 11.5 K 9010-R K 61 K 61 L

WP 5,1 16.0 K 9020-16R K 62 K 62 L

Implant connection NP 3,5 Diameter (mm) 11.5 Article Number K 9800-R Abutment screw K 60 Laboratory screw K 60 L Please note: This is used with Scanbody 2. generation.

RP 4,1 11.5 K 9810-R K 61 K 61 L

WP 5,1 16.0 K 9820-16R K 62 K 62 L

PreFace® abutment Titanium base Zirconium abutment 2nd Generation

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 Chimney height 5.5 (mm) Gingiva height (mm) 0,6 Article Number K 1100 Abutment screw K 60 Laboratory screw K 60 L Please note: This is used with Scanbody 2. generation.

RP 4,1 5.5

WP 5,1 5.5

0,6 K 1110 K 61 K 61 L

0,6 K 1120 K 62 K 62 L

Scanbody 2nd Generation • Titanium

grade 5 KV coated • incl. retention screw • specially

Titanium base Bridges/ bars 2nd Generation • rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 RP 4,1 Article Number K 1400 K 1410 Please note: The Scanbody is sterilisable and for intra-oral scanning. Implant connection NP 3,5 Chimney height 3.5 (mm) Gingiva height (mm) 0,6 Article Number K 1500 Abutment screw K 60 Laboratory screw K 60 L Please note: This is used with Scanbody 2. generation.

RP 4,1 3.5

WP 5,1 3.5

0,6 K 1510 K 61 K 61 L

0,6 K 1520 K 62 K 62 L

WP 5,1 K 1420

MedentiCAD abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NP 3,5 RP 4,1 Article Number K 900001 K 901001 Abutment screw K 60 K 61 Laboratory screw K 60 L K 61 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

WP 5,1 K 902001 K 62 K 62 L


140

» K-Series «

» K-Series «

Nobel Biocare® Brånemark®

MedentiCAD abutment

141

MedentiBASE prosthetic components

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.

• K

Implant connection NP 3,5 RP 4,1 Article Number K 900004 K 901004 Abutment screw K 60 K 61 Laboratory screw K 60 L K 61 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

WP 5,1 K 902004 K 62 K 62 L

7600 MedentiBASE bridge screw UG • K 4700 MedentiBASE titanium cap incl. bridge screw • K 4710 MedentiBASE plastic cap incl. bridge screw • K 4720 MedentiBASE gold cap, castable incl. bridge screw • K 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

Titanium grade 5 KV

K 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" K 4720

K 7600

K 4700

Short K 4800

Short K 4810

Long K 4820

Long K 4830

K 4840

MedentiBASE adhesive cap for passive-fit

MedentiCAD wax-up base • Steel • incl.

Nobel Biocare® Brånemark®

• K

abutment screw

Implant connection Article Number Please note: For use on the model only!

NP 3,5 K 9100

RP 4,1 K 9110

WP 5,1 K 9120

4800 MedentiBASE adhesive cap Short incl. bridge screw • K 4810 MedentiBASE adhesive casing Short • K 4820 MedentiBASE adhesive cap Long incl. bridge screw • K 4830 MedentiBASE adhesive casing Long

Version Article Number

MedentiBASE scanbody MedentiBASE abutment straight • Titanium

• Titanium

grade 5 KV specially coated • incl. bridge screw

grade 5 KV torque: 35 Ncm

• Recommended

Article Number Please note: Implant connection Gingiva height (mm) Article Number

NP 3,5 2,5 K 4000

NP 3,5 3,5 K 4100

NP 3,5 4,5 K 4200

MedentiBASE abutment straight • Titanium

grade 5 KV • Recommended torque: 35 Ncm

K 4900 The Scanbody is sterilisable and for intra-oral scanning.

MedentiBASE accessories • M

11-6 Placement instrument MedentiBASE abutment • K 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

Article Number

K 4620

4630

M 11-6

80

MedentiBASE finisher Implant connection Gingiva height (mm) Article Number

RP 4,1 2,5 K 4010

RP 4,1 3,5 K 4110

RP 4,1 4,5 K 4210

• M

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head Article Number Please note:

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capK 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.


142

» K-Series «

» K-Series «

Nobel Biocare® Brånemark®

MedentiLOC abutment straight

MedentiLOC Laboratory implant

• Titanium

• Stainless

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

Implant connection NP 3,5 NP 3,5 NP 3,5 NP 3,5 NP 3,5 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number K 2000 K 2100 K 2200 K 2300 K 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

Nobel Biocare® Brånemark®

143

steel

Version Article Number

straight 56

Novaloc abutment straight • Titanium

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm

Implant connection RP 4,1 RP 4,1 RP 4,1 RP 4,1 RP 4,1 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number K 6010 K 6110 K 6210 K 6310 K 6410 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

• titanium

Implant connection RP 4,1 RP 4,1 RP 4,1 RP 4,1 RP 4,1 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number K 2010 K 2110 K 2210 K 2310 K 2410 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

Novaloc Processing package • Matrix

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert • Retention

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

Implant connection WP 5,1 WP 5,1 WP 5,1 WP 5,1 WP 5,1 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number K 2020 K 2120 K 2220 K 2320 K 2420 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Novaloc Laboratory implant • Stainless

steel

Novaloc Processing package housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

Material Matrix housing Article Number Please note:

Version Article Number

straight 58

• Matrix

• Retention

Optiloc abutment straight • Titanium

Material Matrix housing Article Number Please note:

Titanium

Peek

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®. Implant connection RP 4,1 RP 4,1 RP 4,1 RP 4,1 RP 4,1 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number K 5010 K 5110 K 5210 K 5310 K 5410 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.


144

» K-Series «

» K-Series «

Nobel Biocare® Brånemark®

145

Planning abutment set

Optiloc Processing package housing, titanium insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package

Nobel Biocare® Brånemark®

• 3

piece

• Matrix

• Retention

Material Matrix housing Article Number Please note:

Article Number Content:

Titanium 5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.

Insert Processing holder prosthetic • Stainless

Placement instrument Optiloc abutment • Hardened

KPS KP 110, KP 210-1, KP 210-2

steel

stainless steel

Version Article Number

Manual and ratchet M 59

Optiloc implant analogue

Implant connection Article Number

Processing holder, prosthetics • fits

all inserts steel

• Stainless

• Aluminium

Article Number Version Article Number

4 piece 2102.0024

Planning abutment straight • Aluminium

NP 3,5 K 40

red coated

Implant connection Gingiva height (mm) Diameter (mm) Article Number

RP 4,1 2,5 4,8 KP 110

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2

RP 4,1 2,5 4,8 KP 210-1 KP 210-2

Planning abutment angled 18° • Aluminium

red coated 1 = angled over flat • Type 2 = angled over corner • Type

Type 1

Type 2

M 04

RP 4,1 K 41

WP 5,1 K 42


The L-Series abutments are compatible with

» L-SERIES «

Straumann® Bone Level®

DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments.

Type 1

Type 2

angled over flat

angled over edge

Products indicated with ® are registered brand names of respective manufactures.


148

» L-Series «

» L-Series «

Straumann® Bone Level®

Implant pick-up Open tray

Abutment screw

• incl.

• Titanium

retention screw steel

• Stainless

• Torx®

T6

NC 3,3 short L 10

RC 4,1/4,8 short L 11

149

grade 5 KV

Article Number Implant connection Version Article Number

Straumann® Bone Level®

L 60

L 63

Laboratory screw • red

coated

Implant pick-up Open tray • incl.

retention screw steel

Article Number

• Stainless

L 60 L

Temporary abutment • Titanium

Implant connection Version Article Number

NC 3,3 long L 20

RC 4,1/4,8 long L 21

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Laboratory implant • Stainless

steel

Implant connection Article Number

NC 3,3 L 50

RC 4,1/4,8 L 51

Implant connection Article Number Abutment screw Laboratory screw

NC 3,3 L 3500 L 60 L 60 L

RC 4,1/4,8 L 3510 L 60 L 60 L

Implant connection Article Number Abutment screw Laboratory screw

NC 3,3 L 3700 L 60 L 60 L

RC 4,1/4,8 L 3710 L 63

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

NC 3,3 1,5 4,2 L 100 L 60 L 60 L

RC 4,1/4,8 1,5 5,0 L 110 L 60 L 60 L

Temporary abutment rotating • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Laboratory implant CADCAM • Stainless

steel

Implant connection NC 3,3 Article Number L 80 Please note: This is used for 3D printmodels with Scanbody 2. generation.

RC 4,1/4,8 L 81

Standard abutment straight • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Placement instrument laboratory implant CADCAM • Stainless

steel

Implant connection Article Number

NC 3,3 L 80 T

RC 4,1/4,8 L 81 T


150

» L-Series «

» L-Series «

Straumann® Bone Level®

Standard abutment straight

Castable gold abutment rotating

• Titanium

• AU

grade 5 KV abutment screw • Recommended torque: 35 Ncm

Straumann® Bone Level®

151

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm

• incl.

• incl.

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

NC 3,3 3,0 4,2 L 100-3 L 60 L 60 L

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

RC 4,1/4,8 3,0 5,0 L 110-3 L 60 L 60 L

NC 3,3 0,23 L 300 R L 60 L 60 L

RC 4,1/4,8 0,38 L 310 R L 63

Solid abutment straight

Standard abutment angled 18°

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm • incl.

Type 1

Type 2

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

NC 3,3 1,5 4,2 L 200-1 L 200-2 L 60 L 60 L

Solid abutment angled 18°

Standard abutment angled 18°

• Titanium

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV • incl. abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm Type 1

Type 2

Implant connection NC 3,3 RC 4,1/4,8 Gingiva height (mm) 3,5 3,5 Diameter (mm) 5,0 5,5 Article Number L 400 L 410 Abutment screw L 60 L 60 Laboratory screw L 60 L L 60 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

RC 4,1/4,8 1,5 5,0 L 210-1 L 210-2 L 60 L 60 L

Type 1

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

NC 3,3 3,0 4,2 L 200-1-3 L 200-2-3 L 60 L 60 L

RC 4,1/4,8 3,0 5,0 L 210-1-3 L 210-2-3 L 60 L 60 L

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

NC 3,3 0,31 L 300 L 60 L 60 L

RC 4,1/4,8 0,53 L 310 L 60 L 60 L

Castable gold abutment • AU

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm • incl.

Type 2

Implant connection NC 3,3 RC 4,1/4,8 Gingiva height (mm) 3,5 3,5 Diameter (mm) 5,0 5,5 Article No. Type 1 L 500-1 L 510-1 Article No. Type 2 L 500-2 L 510-2 Abutment screw L 60 L 60 Laboratory screw L 60 L L 60 L Please note: The Solid abutment will be delievered additional with Laboratory screw.


152

» L-Series «

» L-Series «

Straumann® Bone Level®

POC abutment

153

Titanium base Zirconium abutment 1st Generation

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NC 3,3 Article Number L 900 Abutment screw L 60 Laboratory screw L 60 L Please note: For pressing on a individual ceramics Emergence profile.

RC 4,1/4,8 L 910 L 60 L 60 L

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: Just for use with 3M ESPE Lava™.

Pulse opaque • POC

Straumann® Bone Level®

NC 3,3 4,0

RC 4,1/4,8 4,0

0,7 L 800 LV L 60 L 60 L

0,65 L 810 LV L 60 L 60 L

Implant connection Article Number Please note: This is used for Titanium base 1. generation.

NC 3,3 L 00 W

RC 4,1/4,8 L 10 W

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

NC 3,3 3.5

RC 4,1/4,8 3.5

1,0 L 1000 L 60 L 60 L

0,8 L 1010 L 60 L 60 L

abutment

Scanbody 1st Generation • Peek • incl.

Amount Article Number Please note:

retention screw

4 grams OP 90 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Pulse press blank • POC

abutment

Colour Article Number Please note:

A3 B2 C2 D2 A2 P 90 P 91 P 92 P 93 P 94 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 1. generation.

NC 3,3 4,0

RC 4,1/4,8 4,0

1,2 L 801 L 60 L 60 L

1,0 L 811 L 60 L 60 L

Titanium base Zirconium abutment 2nd Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.


154

» L-Series «

» L-Series «

Straumann® Bone Level®

Titanium base Zirconium abutment 2nd Generation

PreFace® abutment

• Titanium

• incl.

Straumann® Bone Level®

155

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

NC 3,3 5.5

RC 4,1/4,8 5.5

1,0 L 1100 L 60 L 60 L

0,8 L 1110 L 60 L 60 L

Implant connection Diameter (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

NC 3,3 16.0 L 9800-16R L 60 L 60 L

RC 4,1/4,8 16.0 L 9810-16R L 60 L 60 L

Scanbody 2nd Generation Titanium base Bridges/ bars 2nd Generation

• Titanium

grade 5 KV coated • incl. retention screw • specially

• rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

NC 3,3 3.5

RC 4,1/4,8 3.5

1,0 L 1500 L 60 L 60 L

0,8 L 1510 L 63

Implant connection NC 3,3 Article Number L 1400 Please note: The Scanbody is sterilisable and for intra-oral scanning.

RC 4,1/4,8 L 1410

Implant connection NC 3,3 Article Number L 900001 Abutment screw L 60 Laboratory screw L 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

RC 4,1/4,8 L 901001 L 60 L 60 L

Implant connection NC 3,3 Article Number L 900004 Abutment screw L 60 Laboratory screw L 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

RC 4,1/4,8 L 901004 L 60 L 60 L

MedentiCAD abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

PreFace® abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NC 3,3 NC 3,3 Diameter (mm) 11.5 16.0 Article Number L 9000-R L 9000-16R Abutment screw L 60 L 60 Laboratory screw L 60 L L 60 L Please note: This is used with Scanbody 2. generation.

RC 4,1/4,8 11.5 L 9010-R L 60 L 60 L

RC 4,1/4,8 16.0 L 9010-16R L 60 L 60 L

MedentiCAD abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.


156

» L-Series «

» L-Series «

Straumann® Bone Level®

MedentiCAD wax-up base

MedentiBASE scanbody

• Steel

• Titanium

• incl.

Straumann® Bone Level®

157

grade 5 KV specially coated • incl. bridge screw

abutment screw

Implant connection Article Number Please note: For use on the model only!

NC 3,3 L 9100

Article Number Please note:

RC 4,1/4,8 L 9110

L 4900 The Scanbody is sterilisable and for intra-oral scanning.

MedentiBASE accessories • M

11-6 Placement instrument MedentiBASE abutment • L 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 35 Ncm

• Recommended

Implant connection Gingiva height (mm) Article Number

NC 3,3 0,5 L 4000

NC 3,3 1,5 L 4100

NC 3,3 2,5 L 4200

NC 3,3 3,5 L 4300

NC 3,3 4,5 L 4400

MedentiBASE abutment straight • Titanium

RC 4,1/4,8 1,5 L 4110

RC 4,1/4,8 2,5 L 4210

RC 4,1/4,8 3,5 L 4310

RC 4,1/4,8 4,5 L 4410

80

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capL 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

MedentiBASE prosthetic components

Implant connection NC 3,3 NC 3,3 NC 3,3 NC 3,3 NC 3,3 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number L 2000 L 2100 L 2200 L 2300 L 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• L

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

L 7600

L 4700

L 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" L 4720

Titanium grade 5 KV L 4840

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

MedentiBASE adhesive cap for passive-fit 4800 MedentiBASE adhesive cap Short incl. bridge screw • L 4810 MedentiBASE adhesive casing Short • L 4820 MedentiBASE adhesive cap Long incl. bridge screw • L 4830 MedentiBASE adhesive casing Long

M 11-6

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head

grade 5 KV torque: 35 Ncm

RC 4,1/4,8 0,5 L 4010

4630

• M

Article Number Please note:

Implant connection Gingiva height (mm) Article Number

L 4620

MedentiBASE finisher

• Recommended

7600 MedentiBASE bridge screw Torx® T6 • L 4700 MedentiBASE titanium cap incl. bridge screw • L 4710 MedentiBASE plastic cap incl. bridge screw • L 4720 MedentiBASE gold cap, castable incl. bridge screw • L 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

Article Number

Implant connection RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number L 2010 L 2110 L 2210 L 2310 L 2410 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• L

Version Article Number

Short L 4800

Short L 4810

Long L 4820

Long L 4830


158

» L-Series «

» L-Series «

Straumann® Bone Level®

MedentiLOC abutment angled 15°

MedentiLOC Laboratory implant

• Titanium

• Stainless

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm • titanium

Type 1

Type 2

Implant connection NC 3,3 NC 3,3 NC 3,3 NC 3,3 NC 3,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article No. Type 1 L 2500-1 L 2600-1 L 2700-1 L 2800-1 L 2900-1 Article No. Type 2 L 2500-2 L 2600-2 L 2700-2 L 2800-2 L 2900-2 Abutment screw L 62 L 62 L 62 L 62 L 62 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

• Titanium

Hex

• Titanium

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

Implant connection RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article No. Type 1 L 2510-1 L 2610-1 L 2710-1 L 2810-1 L 2910-1 Article No. Type 2 L 2510-2 L 2610-2 L 2710-2 L 2810-2 L 2910-2 Abutment screw L 62 L 62 L 62 L 62 L 62 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

Novaloc Processing package

• Titanium

grade 5 KV coated • Recommended torque: 35 Ncm

• Retention

• LTC

Material Matrix housing Article Number Please note:

Titanium

Peek

Implant connection RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number L 6010 L 6110 L 6210 L 6310 L 6410 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument MedentiLOC abutment, angled • Ball

Hex

Implant connection NC 3,3 NC 3,3 NC 3,3 NC 3,3 NC 3,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number L 6000 L 6100 L 6200 L 6300 L 6400 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Novaloc abutment straight

• Matrix

• Hardened

L 62

Novaloc abutment straight

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm • titanium

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

angled 57

grade 5 KV Article Number

• Titanium

straight 56

Abutment screw MedentiLOC abutment, angled

MedentiLOC abutment angled 15°

Type 2

159

steel

Version Article Number

• Ball

Type 1

Straumann® Bone Level®

stainless steel Version Article Number

Contra-angle M 03-7

Manual and ratchet M 10-7


160

» L-Series «

» L-Series «

Straumann® Bone Level®

Novaloc abutment angled 15°

Novaloc Laboratory implant

• Titanium

• Stainless

grade 5 KV coated • incl. abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm • LTC

Type 1

Type 2

Implant connection NC 3,3 NC 3,3 NC 3,3 NC 3,3 NC 3,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article No. Type 1 L 6500-1 L 6600-1 L 6700-1 L 6800-1 L 6900-1 Article No. Type 2 L 6500-2 L 6600-2 L 6700-2 L 6800-2 L 6900-2 Abutment screw L 64 L 64 L 64 L 64 L 64 Please note: To screw in the angled Novaloc abutments you need the special Placement instrument Ball-Torx M 03-8 or M 10-8.

Version Article Number

Abutment screw Novaloc abutment, angled • Titanium • Ball

grade 5 KV Torx®

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

Implant connection RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article No. Type 1 L 6510-1 L 6610-1 L 6710-1 L 6810-1 L 6910-1 Article No. Type 2 L 6510-2 L 6610-2 L 6710-2 L 6810-2 L 6910-2 Abutment screw L 64 L 64 L 64 L 64 L 64 Please note: To screw in the angled Novaloc abutments you need the special Placement instrument Ball-Torx M 03-8 or M 10-8.

Implant connection NC 3,3 NC 3,3 NC 3,3 NC 3,3 NC 3,3 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number L 5000 L 5100 L 5200 L 5300 L 5400 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Optiloc abutment straight

• Matrix

• LTC

• Titanium

grade 5 KV coated • Recommended torque: 35 Ncm

Material Matrix housing Article Number Please note:

Titanium

Peek

Implant connection RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 RC 4,1/4,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number L 5010 L 5110 L 5210 L 5310 L 5410 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument Novaloc abutment, angled

Optiloc Processing package

• Hardened • Ball

L 64

• Titanium

Novaloc Processing package housing, titanium/PEEK • Retention insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

angled 59

Optiloc abutment straight

grade 5 KV coated • incl. abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm • LTC

straight 58

Article Number

• Titanium

Type 2

161

steel

Novaloc abutment angled 15°

Type 1

Straumann® Bone Level®

stainless steel Torx®

• Matrix

housing, titanium insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • Retention

Version Article Number

Contra-angle M 03-8

Manual and ratchet M 10-8

Material Matrix housing Article Number Please note:

Titanium 5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.


162

» L-Series «

» L-Series «

Straumann® Bone Level®

Placement instrument Optiloc abutment

Insert Processing holder prosthetic

• Hardened

• Stainless

stainless steel

Version

Optiloc implant analogue

163

steel

Manual and ratchet M 59

Article Number

Straumann® Bone Level®

Implant connection Article Number

NC 3,3 L 40

Processing holder, prosthetics

• Aluminium

• fits

all inserts steel

• Stainless

Version Article Number

4 piece 2102.0024

Planning abutment straight • Aluminium

red coated

Implant connection Gingiva height (mm) Diameter (mm) Article Number

NC 3,3 1,5/3,0 4,2 LP 100-3

RC 4,1/4,8 1,5/3,0 5,0 LP 110-3

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2

NC 3,3 1,5/3,0 4,2 LP 200-1-3 LP 200-2-3

RC 4,1/4,8 1,5/3,0 5,0 LP 210-1-3 LP 210-2-3

Planning abutment angled 18° • Aluminium

red coated 1 = angled over flat • Type 2 = angled over corner • Type

Type 1

Type 2

Planning abutment set • 6

piece

Article Number Content:

LPS LP 100-3, LP 110-3, LP 200-1-3, LP 200-2-3, LP 210-1-3, LP 210-2-3

Article Number

M 04

RC 4,1/4,8 L 41


The N-Series abutments are compatible with

» N-SERIES «

Straumann® Tissue Level®

DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments.

Type 1

Type 2

angled over flat

angled over corner

Products indicated with ® are registered brand names of respective manufactures.


166

» N-Series «

» N-Series «

Straumann® Tissue Level®

Implant pick-up Open tray

Abutment screw

• incl.

• Titanium

retention screw steel

• Stainless

• Torx®

Implant connection Version Article Number

NN 3,5 short N 10

RN 4,8 short N 11

WN 6,5 short N 12

T6

Straumann® Tissue Level®

167

grade 5 KV

Article Number

N 60

N 61

N 62

N 65

Article Number

N 60 L

N 61 L

N 62 L

N 65 L

Implant connection Article Number Abutment screw Laboratory screw

NN 3,5 N 3500 N 60 N 60 L

NNC 3,5 N 3530 N 65 N 65 L

RN 4,8 N 3510 N 62 N 62 L

WN 6,5 N 3520 N 62 N 62 L

NNC 3,5 N 3730 N 65 N 65 L

RN 4,8 N 3710 N 62 N 62 L

WN 6,5 N 3720 N 62 N 62 L

RN 4,8 0 3,5 N 110 N 61 N 61 L

RN 4,8 0 3,5 N 110L N 61 N 61 L

WN 6,5 0 4,3 N 120 N 61 N 61 L

Laboratory screw • red

coated

Implant pick-up Open tray • incl.

retention screw steel

• Stainless

Temporary abutment • Titanium

Implant connection Version Article Number

NN 3,5 long N 20

RN 4,8 long N 21

WN 6,5 long N 22

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Laboratory implant • Stainless

steel

Implant connection Article Number

NN 3,5 N 50

NNC 3,5 N 53

RN 4,8 N 51

WN 6,5 N 52

Temporary abutment rotating • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Laboratory implant CADCAM • Stainless

Implant connection Article Number Abutment screw Laboratory screw

steel

Implant connection NNC 3,5 RN 4,8 Article Number N 83 N 81 Please note: This is used for 3D printmodels with Scanbody 2. generation.

WN 6,5 N 82

Standard abutment straight • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Placement instrument laboratory implant CADCAM • Stainless

steel

Implant connection Article Number

NNC 3,5 N 83 T

RN 4,8 N 81 T

WN 6,5 N 82 T

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

NN 3,5 1,5 4,0 N 100 N 60 N 60 L


168

» N-Series «

» N-Series «

Straumann® Tissue Level®

Standard abutment angled 16°

Solid abutment

• Titanium

• incl.

grade 5 KV abutment screw • Recommended torque: 35 Ncm

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm Type 2

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

NN 3,5 1,5 4,0 N 200 N 60 N 60 L

RN 4,8 0 3,5 N 210-1 N 210-2 N 61 N 61 L

WN 6,5 0 4,3 N 220-1 N 220-2 N 61 N 61 L

Implant connection NN 3,5 RN 4,8 Gingiva height (mm) 0 0 Diameter (mm) 3,5 4,8 Article Number N 400 N 410 Abutment screw N 60 N 62 Laboratory screw N 60 L N 62 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

Standard abutment angled 21°

Solid abutment 1-piece

• Titanium

• (for

grade 5 KV use by dentists only) • Recommended torque: 35 Ncm

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 35 Ncm Type 2

WN 6,5 0 6,5 N 420 N 62 N 62 L

• Titanium

• incl.

Type 1

169

• Titanium

• incl.

Type 1

Straumann® Tissue Level®

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

RN 4,8 0 3,5 N 210-1-21 N 210-2-21 N 61 N 61 L

Implant connection Height (mm) Diameter (mm) Article Number

RN 4,8 4,0 3,5 N 110-40

RN 4,8 5,5 3,5 N 110-55

RN 4,8 7,0 3,5 N 110-70

WN 6,5 4,0 4,3 N 120-40

WN 6,5 5,5 4,3 N 120-55

Implant connection Article Number

RN 4,8 N 51-40

RN 4,8 N 51-55

RN 4,8 N 51-70

WN 6,5 N 52-40

WN 6,5 N 52-55

Implant connection NN 3,5 RN 4,8 Article Number N 900 N 910 Abutment screw N 60 N 62 Laboratory screw N 60 L N 62 L Please note: For pressing on a individual ceramics Emergence profile.

WN 6,5 N 920 N 62 N 62 L

Laboratory implant • Aluminium • Solid

Castable gold abutment

abutment

• AU

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

NN 3,5 0,42 N 300 N 60 N 60 L

RN 4,8 0,44 N 310 N 62 N 62 L

WN 6,5 0,92 N 320 N 62 N 62 L

POC abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.

Castable gold abutment rotating • AU

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

NN 3,5 0,42 N 300 R N 60 N 60 L

RN 4,8 0,42 N 310 R N 62 N 62 L

WN 6,5 0,89 N 320 R N 62 N 62 L


170

» N-Series «

» N-Series «

Straumann® Tissue Level®

Pulse opaque

Scanbody 1st Generation

• POC

• Peek

abutment

• incl.

Amount Article Number Please note:

• POC

171

retention screw

4 grams OP 90 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Pulse press blank

Straumann® Tissue Level®

Implant connection NN 3,5 Article Number N 00 W Please note: This is used for Titanium base 1. generation.

RN 4,8 N 10 W

WN 6,5 N 20 W

Implant connection NN 3,5 NNC 3,5 Chimney height 3.5 3.5 (mm) Gingiva height (mm) 0,6 0,6 Article Number N 1000 N 1030 Abutment screw N 60 N 65 Laboratory screw N 60 L N 65 L Please note: This is used with Scanbody 2. generation.

RN 4,8 3.5

WN 6,5 3.5

0,1 N 1010 N 62 N 62 L

0,1 N 1020 N 62 N 62 L

RN 4,8 5.5

WN 6,5 5.5

0,1 N 1110 N 62 N 62 L

0,1 N 1120 N 62 N 62 L

Titanium base Zirconium abutment 2nd Generation

abutment

• Titanium

Colour Article Number Please note:

A3 B2 C2 D2 A2 P 90 P 91 P 92 P 93 P 94 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NN 3,5 Chimney height 4,0 (mm) Gingiva height (mm) 0,6 Article Number N 800 Abutment screw N 60 Laboratory screw N 60 L Please note: This is used with Scanbody 1. generation.

RN 4,8 4,0 0,15 N 810 N 62 N 62 L

WN 6,5 4,0 0,3 N 820 N 62 N 62 L

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: Just for use with 3M ESPE Lava™.

NN 3,5 4,0

RN 4,8 4,0

WN 6,5 4,0

0,6 N 800 LV N 60 N 60 L

0,15 N 810 LV N 62 N 62 L

0,3 N 820 LV N 62 N 62 L

Titanium base Zirconium abutment 2nd Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NNC 3,5 Chimney height 5.5 (mm) Gingiva height (mm) 0,6 Article Number N 1130 Abutment screw N 65 Laboratory screw N 65 L Please note: This is used with Scanbody 2. generation.


172

» N-Series «

» N-Series «

Straumann® Tissue Level®

Straumann® Tissue Level®

173

MedentiCAD abutment

Titanium base Bridges/ bars 2nd Generation

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

• rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NNC 3,5 Chimney height 3.5 (mm) Gingiva height (mm) 0,35 Article Number N 1530 Abutment screw N 65 Laboratory screw N 65 L Please note: This is used with Scanbody 2. generation.

RN 4,8 3.5

WN 6,5 3.5

0,1 N 1510 N 62 N 62 L

0,1 N 1520 N 62 N 62 L

Implant connection NN 3,5 NNC 3,5 RN 4,8 Article Number N 900001 N 903001 N 901001 Abutment screw N 60 N 65 N 62 Laboratory screw N 60 L N 65 L N 62 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

WN 6,5 N 902001 N 62 N 62 L

Implant connection NNC 3,5 RN 4,8 Article Number N 903004 N 901004 Abutment screw N 65 N 62 Laboratory screw N 65 L N 62 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

WN 6,5 N 902004 N 62 N 62 L

MedentiCAD abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.

PreFace abutment ®

• Titanium

grade 5 KV abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NNC 3,5 RN 4,8 RN 4,8 Diameter (mm) 11.5 11.5 16.0 Article Number N 9030-R N 9010-R N 9010-16R Abutment screw N 65 N 62 N 62 N 65 L N 62 L N 62 L Laboratory screw Please note: This is used with Scanbody 2. generation.

WN 6,5 11.5 N 9020-R N 62 N 62 L

WN 6,5 16.0 N 9020-16R N 62 N 62 L

MedentiCAD wax-up base • Steel • incl.

abutment screw

PreFace abutment ®

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 35 Ncm • incl.

Implant connection NNC 3,5 Diameter (mm) 11.5 Article Number N 9830-R Abutment screw N 65 Laboratory screw N 65 L Please note: This is used with Scanbody 2. generation.

RN 4,8 16.0 N 9810-16R N 62 N 62 L

WN 6,5 16.0 N 9820-16R N 62 N 62 L

Implant connection NN 3,5 Article Number N 9100 Please note: For use on the model only!

NNC 3,5 N 9130

RN 4,8 N 9110

WN 6,5 N 9120

Implant connection Gingiva height (mm) Article Number

NNC 3,5 2,5 N 4230

NNC 3,5 3,5 N 4330

NNC 3,5 4,5 N 4430

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 35 Ncm

• Recommended

Scanbody 2nd Generation • Titanium

grade 5 KV coated • incl. retention screw • specially

Implant connection NNC 3,5 RN 4,8 Article Number N 1430 N 1410 Please note: The Scanbody is sterilisable and for intra-oral scanning.

WN 6,5 N 1420

NNC 3,5 0,5 N 4030

NNC 3,5 1,5 N 4130


174

» N-Series «

» N-Series «

Straumann® Tissue Level®

MedentiBASE prosthetic components

MedentiBASE abutment straight

• NNC

• Titanium

7600 MedentiBASE bridge screw Torx® T6 • NNC 4700 MedentiBASE titanium cap incl. bridge screw • NNC 4710 MedentiBASE plastic cap incl. bridge screw • NNC 4720 MedentiBASE gold cap, castable incl. bridge screw • NNC 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

Material

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

Article Number

NNC 7600

NNC 4700

NNC 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" NNC 4720

Implant connection Gingiva height (mm) Article Number

NNC 4840

RN 4,8 0 N 4010

MedentiBASE prosthetic components • N

Version Article Number

Short NNC 4800

Short NNC 4810

Long NNC 4820

Long NNC 4830

7600 MedentiBASE bridge screw Torx® T6 • N 4700 MedentiBASE titanium cap incl. bridge screw • N 4710 MedentiBASE plastic cap incl. bridge screw • N 4720 MedentiBASE gold cap, castable incl. bridge screw • Recommended torque: 15 Ncm

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

N 7600

N 4700

N 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" N 4720

Short N 4800

Short N 4810

MedentiBASE adhesive cap for passive-fit

MedentiBASE scanbody • Titanium

• N

4800 MedentiBASE adhesive cap Short incl. bridge screw • N 4810 MedentiBASE adhesive casing Short Article Number

Version Article Number

NNC 4900

MedentiBASE accessories MedentiBASE laboratory implant CADCAM • NNC 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • M 11-6 Placement instrument MedentiBASE abutment • M 11-6 Placement instrument MedentiBASE abutment

grade 5 KV torque: 35 Ncm

Titanium grade 5 KV

• NNC

grade 5 KV specially coated • incl. bridge screw • für Brücken und Stege für intraoralen Scan geeignet sterilisierbar

175

• Recommended

MedentiBASE adhesive cap for passive-fit 4800 MedentiBASE adhesive cap Short incl. bridge screw • NNC 4810 MedentiBASE adhesive casing Short • NNC 4820 MedentiBASE adhesive cap Long incl. bridge screw • NNC 4830 MedentiBASE adhesive casing Long

Straumann® Tissue Level®

MedentiBASE scanbody

• 80

• Titanium

grade 5 KV specially coated • incl. bridge screw Article Number

NNC 4620

4630

M 11-6

80

Article Number Please note:

N 4900 The Scanbody is sterilisable and for intra-oral scanning.

MedentiBASE accessories MedentiBASE finisher

• M

11-6 Placement instrument MedentiBASE abutment • N 11 Implant pick-up Open tray • N 51 Laboratory implant • N 81 Laboratory implant CADCAM

• M

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head

Article Number Article Number Please note:

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic cap NNC 4710 after casting. The Finishers are used in the Processing holder prosthetic M 04.

M 11-6

N 51

N 81

N 11


176

» N-Series «

Straumann® Tissue Level®

MedentiBASE finisher

» N-Series «

Straumann® Tissue Level®

177

MedentiLOC abutment angled 15°

• M

18 MedentiBASE finisher Screw head • M 19 MedentiBASE finisher Connection geometry

• Titanium

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 35 Ncm • titanium

Article Number Please note:

M 18 M 19 This is used to finish the fitting surfaces of the MedentiBASE plastic capN 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

Type 1

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm

Implant connection RN 4,8 RN 4,8 RN 4,8 RN 4,8 RN 4,8 Gingiva height (mm) 0,5 1,5 2,5 3,5 4,5 Article Number N 2510 N 2610 N 2710 N 2810 N 2910 Abutment screw N 64 N 64 N 64 N 64 N 64 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

• titanium

Novaloc Processing package Implant connection NNC 3,5 NNC 3,5 NNC 3,5 NNC 3,5 NNC 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number N 2030 N 2130 N 2230 N 2330 N 2430 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

• Matrix

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert • Retention

Material Matrix housing Article Number Please note:

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument MedentiLOC abutment, angled Implant connection RN 4,8 RN 4,8 RN 4,8 RN 4,8 RN 4,8 Gingiva height (mm) 0,5 1,5 2,5 3,5 4,5 Article Number N 2010 N 2110 N 2210 N 2310 N 2410 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• Hardened • Ball

Hex

stainless steel Version

MedentiLOC abutment straight

MedentiLOC Laboratory implant

• Titanium

• Stainless

grade 5 KV nitride coated • Recommended torque: 35 Ncm • titanium

Implant connection WN 6,5 WN 6,5 WN 6,5 WN 6,5 WN 6,5 Gingiva height (mm) 0,5 1,5 2,5 3,5 4,5 Article Number N 2020 N 2120 N 2220 N 2320 N 2420 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

Contra-angle

Article Number

M 03-7

Manual and ratchet M 10-7

Version Article Number

straight 56

angled 57

steel

Abutment screw MedentiLOC abutment, angled • Titanium • Ball

Hex

grade 5 KV Article Number

N 64


178

» N-Series «

» N-Series «

Straumann® Tissue Level®

Novaloc abutment straight

Placement instrument Novaloc abutment, angled

• Titanium

• Hardened

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

• Ball

Article Number

M 03-8

Manual and ratchet M 10-8

Version Article Number

straight 58

angled 59

steel

• Titanium

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

Implant connection RN 4,8 RN 4,8 RN 4,8 RN 4,8 RN 4,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number N 6010 N 6110 N 6210 N 6310 N 6410 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Abutment screw Novaloc abutment, angled • Titanium • Ball

grade 5 KV Torx®

Article Number

Novaloc abutment angled 15°

Optiloc abutment straight

• Titanium

• Titanium

• LTC

Implant connection RN 4,8 RN 4,8 RN 4,8 RN 4,8 RN 4,8 Gingiva height (mm) 0,5 1,5 2,5 3,5 4,5 Article Number N 6510 N 6610 N 6710 N 6810 N 6910 Abutment screw N 66 N 66 N 66 N 66 N 66 Please note: To screw in the angled Novaloc abutments you need the special Placement instrument Ball-Torx M 03-8 or M 10-8.

Implant connection NNC 3,5 NNC 3,5 NNC 3,5 NNC 3,5 NNC 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number N 5030 N 5130 N 5230 N 5330 N 5430 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Optiloc abutment straight

Novaloc Processing package housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

N 66

grade 5 KV coated • Recommended torque: 35 Ncm

grade 5 KV coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 35 Ncm • LTC

Type 1

Contra-angle

Novaloc Laboratory implant • Stainless

Novaloc abutment straight

179

stainless steel Torx®

Version Implant connection NNC 3,5 NNC 3,5 NNC 3,5 NNC 3,5 NNC 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number N 6030 N 6130 N 6230 N 6330 N 6430 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Straumann® Tissue Level®

• Titanium

grade 5 KV coated • Recommended torque: 35 Ncm • LTC

• Matrix

• Retention

Material Matrix housing Article Number Please note:

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Implant connection RN 4,8 RN 4,8 RN 4,8 RN 4,8 RN 4,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number N 5010 N 5110 N 5210 N 5310 N 5410 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.


180

» N-Series «

» N-Series «

Straumann® Tissue Level®

Optiloc Processing package

Planning abutment angled 21°

• Matrix

• Aluminium

housing, titanium insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package

Straumann® Tissue Level®

181

red coated 1 = angled over flat • Type 2 = angled over corner • Type

• Retention

Type 1

Material Matrix housing Article Number Please note:

Type 2

Titanium

5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument Optiloc abutment

Planning abutment set

• Hardened

• 10

stainless steel

Version

RN 4,8 0 3,5 NP 210-1-21 NP 210-2-21

piece

Manual and ratchet M 59

Article Number

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2

Article Number Content:

NPS NP 100, NP 110, NP 120, NP 200, NP 210-1, NP 210-2, NP 210-1-21, NP 210-2-21, NP 220-1, NP 220-2

Optiloc implant analogue Insert Processing holder prosthetic

• Aluminium

• Stainless

Version Article Number

steel

4 piece 2102.0024 Implant connection Article Number

Planning abutment straight • Aluminium

red coated

NN 3,5 N 40

NNC 3,5 N 43

Processing holder, prosthetics • fits

all inserts steel

• Stainless

Implant connection Gingiva height (mm) Diameter (mm) Article Number

NN 3,5 1,5 4,0 NP 100

RN 4,8 0 3,5 NP 110

WN 6,5 0 4,3 NP 120

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2

NN 3,5 1,5 4,0 NP 200

RN 4,8 0 3,5 NP 210-1 NP 210-2

WN 6,5 0 4,3 NP 220-1 NP 220-2

Planning abutment angled 16° • Aluminium

red coated 1 = angled over flat • Type 2 = angled over corner • Type

Type 1

Type 2

Article Number

M 04

RN 4,8 N 41

WN 6,5 N 42


The R-Series abutments are compatible with

» R-SERIES «

Zimmer Dental® - Tapered Screw-Vent® MIS® - SEVEN® Internal Hex BioHorizons® - Tapered Internal - Internal Plus - Tapered Tissue Level

DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments.

Type 1

Type 2

angled over flat

angled over corner

Products indicated with ® are registered brand names of respective manufactures.


184

» R-Series «

Comparison chart Zimmer Dental® MIS® BioHorizons®

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® BioHorizons® Tapered Internal/Internal Plus/Tissue Level

» R-Series «

Zimmer Dental ®

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® 185 ® BioHorizons Tapered Internal/Internal Plus/Tissue Level

Implant Ø

3,70

4,10

Platform 4,5 mm 4,70

Laboratory implant Ø Article Number Implant connection Medentika R-Series Laboratory implant Article Number

3,50 IA3

3,50 IA3

4,50 IA4

5,70 IA5

3,5

3,5

4,5

5,7

R 50

R 50

R 51

R 52

NarrowPlatform 3,30

3,30

StandardPlatform 3,75

4,20

5,00

6,00

3,30 MN-RSM10

4,20 MD-RSM10

4,20 MD-RSM10

4,20 MD-RSM10

4,50 MW-RSM10

4,50 MW-RSM10

XX

3,50

3,50

3,50

4,50

4,50

XX

R 50

R 50

R 50

R 51

R 51

Platform 3,0 mm 3,00

Platform 3,5 mm 3,80

Platform 4,5 mm 4,60

Platform 5,7 mm 5,80

3,00 TP3IA

3,50 SYIA

4,50 SGIA

5,70 SBIA

XX

3,50

4,50

5,70

XX

R 50

R 51

R 52

MIS ® Implant Ø Laboratory implant Ø Article Number Implant connection Medentika R-Series Laboratory implant Article Number

BioHorizons ® Implant Ø Laboratory implant Ø Article Number Implant connection Medentika R-Series Laboratory implant Article Number

Platform 3,5 mm

Platform 5,7 mm 6,00

WidePlatform


186

» R-Series «

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® BioHorizons® Tapered Internal/Internal Plus/Tissue Level

» R-Series «

Implant pick-up Open tray

Abutment screw

• incl.

• Titanium

retention screw steel

• Stainless

• Hex

Implant connection Version Article Number

D 3,5 short R 10

D 4,5 short R 11

D 5,7 short R 12

1.26

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® 187 ® BioHorizons Tapered Internal/Internal Plus/Tissue Level

grade 5 KV

Article Number

R 60

Article Number

R 60 L

Laboratory screw • red

coated

Implant pick-up Open tray • incl.

retention screw steel

• Stainless

Temporary abutment • Titanium

Implant connection Version Article Number

D 3,5 long R 20

D 4,5 long R 21

D 5,7 long R 22

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Laboratory implant • Stainless

Implant connection Article Number Abutment screw Laboratory screw

steel

Implant connection Article Number

D 3,5 R 50

D 4,5 R 51

D 5,7 R 52

D 3,5 R 3500 R 60 R 60 L

D 4,5 R 3510 R 60 R 60 L

Temporary abutment rotating • Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Laboratory implant CADCAM • Stainless

steel

Implant connection D 3,5 D 4,5 Article Number R 80 R 81 Please note: This is used for 3D printmodels with Scanbody 2. generation.

D 5,7 R 82

Implant connection Article Number Abutment screw Laboratory screw

D 3,5 R 3700 R 60 R 60 L

D 4,5 R 3710 R 60 R 60 L

D 5,7 R 3720 R 60 R 60 L

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

D 3,5 1,0 4,3 R 100-1 R 60 R 60 L

D 4,5 1,0 5,2 R 110-1 R 60 R 60 L

D 5,7 1,0 6,0 R 120-1 R 60 R 60 L

Standard abutment straight • Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Placement instrument laboratory implant CADCAM • Stainless

steel

Implant connection Article Number

D 3,5 R 80 T

D 4,5 R 81 T

D 5,7 R 82 T


188

» R-Series «

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® BioHorizons® Tapered Internal/Internal Plus/Tissue Level

» R-Series «

Standard abutment straight

Castable gold abutment rotating

• Titanium

• AU

grade 5 KV abutment screw • Recommended torque: 30 Ncm

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® 189 ® BioHorizons Tapered Internal/Internal Plus/Tissue Level

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 30 Ncm

• incl.

• incl.

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

D 3,5 2,5 4,5 R 100 R 60 R 60 L

D 4,5 2,5 5,5 R 110 R 60 R 60 L

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

D 5,7 2,5 6,5 R 120 R 60 R 60 L

D 3,5 0,35 R 300 R R 60 R 60 L

D 4,5 0,54 R 310 R R 60 R 60 L

D 5,7 0,87 R 320 R R 60 R 60 L

Solid abutment straight

Standard abutment angled 16°

• Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 30 Ncm • incl.

Type 1

Type 2

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

D 3,5 1,0 4,3 R 200-1-1 R 200-2-1 R 60 R 60 L

D 4,5 1,0 5,2 R 210-1-1 R 210-2-1 R 60 R 60 L

D 5,7 1,0 6,0 R 220-1-1 R 220-2-1 R 60 R 60 L

Implant connection D 3,5 D 4,5 Gingiva height (mm) 3,5 3,5 Diameter (mm) 3,5 4,5 Article Number R 400 R 410 Abutment screw R 60 R 60 Laboratory screw R 60 L R 60 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

D 5,7 3,5 5,7 R 420 R 60 R 60 L

Implant connection D 3,5 D 4,5 Article Number R 900 R 910 Abutment screw R 60 R 60 Laboratory screw R 60 L R 60 L Please note: For pressing on a individual ceramics Emergence profile.

D 5,7 R 920 R 60 R 60 L

POC abutment

Standard abutment angled 16°

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 30 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 30 Ncm • incl.

Type 1

Type 2

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

D 3,5 2,5 4,5 R 200-1 R 200-2 R 60 R 60 L

D 4,5 2,5 5,5 R 210-1 R 210-2 R 60 R 60 L

D 5,7 2,5 6,5 R 220-1 R 220-2 R 60 R 60 L

Pulse opaque • POC

abutment

Castable gold abutment • AU

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 30 Ncm • incl.

Amount Article Number Please note:

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

D 3,5 0,36 R 300 R 60 R 60 L

D 4,5 0,55 R 310 R 60 R 60 L

D 5,7 1,21 R 320 R 60 R 60 L

4 grams OP 90 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.


190

» R-Series «

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® BioHorizons® Tapered Internal/Internal Plus/Tissue Level

Pulse press blank • POC

» R-Series «

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® 191 ® BioHorizons Tapered Internal/Internal Plus/Tissue Level

Titanium base Zirconium abutment 2nd Generation

abutment

• Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Colour Article Number Please note:

A3 B2 C2 D2 A2 P 90 P 91 P 92 P 93 P 94 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Implant connection D 3,5 Chimney height 3.5 (mm) Gingiva height (mm) 0,3 Article Number R 1000 Abutment screw R 60 Laboratory screw R 60 L Please note: This is used with Scanbody 2. generation.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm

D 4,5 3.5

D 5,7 3.5

0,3 R 1010 R 60 R 60 L

0,3 R 1020 R 60 R 60 L

D 4,5 5.5

D 5,7 5.5

0,3 R 1110 R 60 R 60 L

0,3 R 1120 R 60 R 60 L

D 4,5 3.5

D 5,7 3.5

0,3 R 1510 R 60 R 60 L

0,3 R 1520 R 60 R 60 L

• incl.

Titanium base Zirconium abutment 2nd Generation Implant connection D 3,5 Chimney height 4,0 (mm) Gingiva height (mm) 0,5 Article Number R 800 Abutment screw R 60 R 60 L Laboratory screw Please note: This is used with Scanbody 1. generation.

D 4,5 4,0

D 5,7 4,0

0,5 R 810 R 60 R 60 L

0,5 R 820 R 60 R 60 L

• Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Implant connection D 3,5 Chimney height 5.5 (mm) Gingiva height (mm) 0,3 Article Number R 1100 Abutment screw R 60 Laboratory screw R 60 L Please note: This is used with Scanbody 2. generation.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Titanium base Bridges/ bars 2nd Generation Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: Just for use with 3M ESPE Lava™.

D 3,5 4,0 0,5 R 800 LV R 60 R 60 L

D 4,5 4,0 0,5 R 810 LV R 60 R 60 L

D 5,7 4,0 0,5 R 820 LV R 60 R 60 L

Scanbody 1 Generation st

• Peek • incl.

retention screw

Implant connection D 3,5 Article Number R 00 W Please note: This is used for Titanium base 1. generation.

D 4,5 R 10 W

D 5,7 R 20 W

• rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Implant connection D 3,5 Chimney height 3.5 (mm) Gingiva height (mm) 0,3 Article Number R 1500 Abutment screw R 60 Laboratory screw R 60 L Please note: This is used with Scanbody 2. generation.


192

» R-Series «

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® BioHorizons® Tapered Internal/Internal Plus/Tissue Level

» R-Series «

PreFace® abutment

MedentiCAD abutment

• Titanium

• CrCo

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® 193 ® BioHorizons Tapered Internal/Internal Plus/Tissue Level

alloy / CTE 14.1 abutment screw • Recommended torque: 30 Ncm

grade 5 KV abutment screw • Recommended torque: 30 Ncm

• incl.

• incl.

Implant connection D 3,5 D 3,5 D 4,5 Diameter (mm) 11.5 16.0 11.5 Article Number R 9000-R R 9000-16R R 9010-R Abutment screw R 60 R 60 R 60 Laboratory screw R 60 L R 60 L R 60 L Please note: This is used with Scanbody 2. generation.

D 4,5 16.0 R 9010-16R R 60 R 60 L

Implant connection D 3,5 D 4,5 Article Number R 900004 R 901004 Abutment screw R 60 R 60 Laboratory screw R 60 L R 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,7 16.0 R 9020-16R R 60 R 60 L

D 5,7 R 902004 R 60 R 60 L

MedentiCAD wax-up base

PreFace® abutment

• Steel • incl.

• CrCo

alloy / CTE 14.1 • incl. abutment screw • Recommended torque: 30 Ncm

Implant connection D 3,5 Diameter (mm) 16.0 Article Number R 9800-16R Abutment screw R 60 Laboratory screw R 60 L Please note: This is used with Scanbody 2. generation.

D 4,5 16.0 R 9810-16R R 60 R 60 L

D 5,7 16.0 R 9820-16R R 60 R 60 L

abutment screw

Implant connection Article Number Please note: For use on the model only!

D 3,5 R 9100

D 4,5 R 9110

D 5,7 R 9120

Implant connection Gingiva height (mm) Article Number

D 3,5 0,5 R 4000

D 3,5 1,5 R 4100

D 3,5 2,5 R 4200

D 3,5 3,5 R 4300

D 3,5 4,5 R 4400

Implant connection Gingiva height (mm) Article Number

D 4,5 0,5 R 4010

D 4,5 1,5 R 4110

D 4,5 2,5 R 4210

D 4,5 3,5 R 4310

D 4,5 4,5 R 4410

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 30 Ncm

• Recommended

Scanbody 2 Generation nd

• Titanium

grade 5 KV coated • incl. retention screw • specially

Implant connection D 3,5 D 4,5 Article Number R 1400 R 1410 Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 5,7 R 1420

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 30 Ncm

• Recommended

MedentiCAD abutment • Titanium

grade 5 KV abutment screw • Recommended torque: 30 Ncm • incl.

Implant connection D 3,5 D 4,5 Article Number R 900001 R 901001 Abutment screw R 60 R 60 Laboratory screw R 60 L R 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,7 R 902001 R 60 R 60 L


194

» R-Series «

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® BioHorizons® Tapered Internal/Internal Plus/Tissue Level

» R-Series «

MedentiBASE prosthetic components

MedentiLOC abutment straight

• R

• Titanium

7600 MedentiBASE bridge screw Hex 1.26 • R 4700 MedentiBASE titanium cap incl. bridge screw • R 4710 MedentiBASE plastic cap incl. bridge screw • R 4720 MedentiBASE gold cap, castable incl. bridge screw • R 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

grade 5 KV nitride coated • Recommended torque: 30 Ncm • titanium

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

R 7600

R 4700

R 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" R 4720

Titanium grade 5 KV Implant connection D 3,5 D 3,5 D 3,5 D 3,5 D 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number R 2000 R 2100 R 2200 R 2300 R 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

R 4840

MedentiBASE adhesive cap for passive-fit 4800 MedentiBASE adhesive cap Short incl. bridge screw • R 4810 MedentiBASE adhesive casing Short • R 4820 MedentiBASE adhesive cap Long incl. bridge screw • R 4830 MedentiBASE adhesive casing Long

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® 195 ® BioHorizons Tapered Internal/Internal Plus/Tissue Level

MedentiLOC abutment straight

• R

• Titanium

grade 5 KV nitride coated • Recommended torque: 30 Ncm • titanium

Version Article Number

Short R 4800

Short R 4810

Long R 4820

Long R 4830 Implant connection D 4,5 D 4,5 D 4,5 D 4,5 D 4,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number R 2010 R 2110 R 2210 R 2310 R 2410 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

MedentiBASE scanbody • Titanium

grade 5 KV specially coated • incl. bridge screw

MedentiLOC abutment straight Article Number Please note:

R 4900 The Scanbody is sterilisable and for intra-oral scanning.

• Titanium

grade 5 KV nitride coated • Recommended torque: 30 Ncm • titanium

MedentiBASE accessories 11-6 Placement instrument MedentiBASE abutment • R 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

Implant connection D 5,7 D 5,7 D 5,7 D 5,7 D 5,7 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number R 2020 R 2120 R 2220 R 2320 R 2420 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• M

Article Number

R 4620

4630

M 11-6

80

MedentiLOC abutment angled 15°

MedentiBASE finisher

• Titanium

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 30 Ncm • titanium

• M

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head

Type 1

Article Number Please note:

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capR 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

Implant connection D 3,5 D 3,5 D 3,5 D 3,5 D 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number R 2500-1 R 2600-1 R 2700-1 R 2800-1 R 2900-1 Abutment screw R 62 R 62 R 62 R 62 R 62 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.


196

» R-Series «

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® BioHorizons® Tapered Internal/Internal Plus/Tissue Level

» R-Series «

Novaloc Processing package

Novaloc abutment straight

• Matrix

• Titanium

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

grade 5 KV coated • Recommended torque: 30 Ncm • LTC

• Retention

Material Matrix housing Article Number Please note:

Titanium

Peek

Implant connection D 4,5 D 4,5 D 4,5 D 4,5 D 4,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number R 6010 R 6110 R 6210 R 6310 R 6410 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument MedentiLOC abutment, angled

Novaloc abutment angled 15°

• Hardened

• Titanium

• Ball

Hex

stainless steel

grade 5 KV coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 30 Ncm • LTC

Version Article Number

Contra-angle M 03-7

Manual and ratchet M 10-7

Type 1

MedentiLOC Laboratory implant • Stainless

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® 197 ® BioHorizons Tapered Internal/Internal Plus/Tissue Level

steel

Version Article Number

straight 56

angled 57

Implant connection D 3,5 D 3,5 D 3,5 D 3,5 D 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number R 6500-1 R 6600-1 R 6700-1 R 6800-1 R 6900-1 Abutment screw R 63 R 63 R 63 R 63 R 63 Please note: To screw in the angled Novaloc abutments you need the special Placement instrument Ball-Torx M 03-8 or M 10-8.

Novaloc abutment angled 15° • Titanium

grade 5 KV coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 30 Ncm • LTC

Abutment screw MedentiLOC abutment, angled • Titanium • Ball

Hex

Type 1

grade 5 KV

Article Number

R 62

Novaloc abutment straight

Implant connection D 4,5 D 4,5 D 4,5 D 4,5 D 4,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number R 6510-1 R 6610-1 R 6710-1 R 6810-1 R 6910-1 Abutment screw R 63 R 63 R 63 R 63 R 63 Please note: To screw in the angled Novaloc abutments you need the special Placement instrument Ball-Torx M 03-8 or M 10-8.

Novaloc Processing package

• Titanium

grade 5 KV • LTC coated • Recommended torque: 30 Ncm

• Matrix

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert • Retention

Implant connection D 3,5 D 3,5 D 3,5 D 3,5 D 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number R 6000 R 6100 R 6200 R 6300 R 6400 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Material Matrix housing Article Number Please note:

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.


198

» R-Series «

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® BioHorizons® Tapered Internal/Internal Plus/Tissue Level

» R-Series «

Placement instrument Novaloc abutment, angled

Optiloc Processing package

• Hardened

• Matrix

• Ball

stainless steel Torx®

housing, titanium insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • Retention

Version Article Number

Contra-angle M 03-8

Manual and ratchet M 10-8

Novaloc Laboratory implant • Stainless

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® 199 ® BioHorizons Tapered Internal/Internal Plus/Tissue Level

Material Matrix housing Article Number Please note:

Titanium 5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument Optiloc abutment

steel

Version Article Number

straight 58

angled 59

• Hardened

stainless steel

Version

Abutment screw Novaloc abutment, angled

Article Number

• Titanium • Ball

Manual and ratchet M 59

grade 5 KV Torx®

Optiloc implant analogue • Aluminium

Article Number

R 63

Optiloc abutment straight

Version Article Number

• Titanium

grade 5 KV • LTC coated • Recommended torque: 30 Ncm

4 piece 2102.0024

Planning abutment straight Implant connection D 3,5 D 3,5 D 3,5 D 3,5 D 3,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number R 5000 R 5100 R 5200 R 5300 R 5400 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

• Aluminium

red coated

Optiloc abutment straight • Titanium

grade 5 KV coated • Recommended torque: 30 Ncm

Implant connection Gingiva height (mm) Diameter (mm) Article Number

D 3,5 2,5 4,5 RP 100

D 4,5 2,5 5,5 RP 110

D 5,7 2,5 6,5 RP 120

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2

D 3,5 2,5 4,5 RP 200-1 RP 200-2

D 4,5 2,5 5,5 RP 210-1 RP 210-2

D 5,7 2,5 6,5 RP 220-1 RP 220-2

• LTC

Planning abutment angled 18° • Aluminium

Implant connection D 4,5 D 4,5 D 4,5 D 4,5 D 4,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number R 5010 R 5110 R 5210 R 5310 R 5410 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

red coated 1 = angled over flat • Type 2 = angled over corner • Type

Type 1

Type 2


200

» R-Series «

Zimmer Dental® Tapered Screw-Vent® MIS® SEVEN Internal Hex® BioHorizons® Tapered Internal/Internal Plus/Tissue Level

Planning abutment set • 9

piece

Article Number Content:

RPS RP 100, RP 110, RP 120, RP 200-1, RP 200-2, RP 210-1, RP 210-2, RP 220-1, RP 2202

Insert Processing holder prosthetic • Stainless

steel

Implant connection Article Number

D 3,5 R 40

Article Number

M 04

Processing holder, prosthetics • fits

all inserts steel

• Stainless

D 4,5 R 41

D 5,7 R 42


The S-Series abutments are compatible with

» S-SERIES «

DENTSPLY Implants® ASTRA TECH OsseoSpeed® TX

Products indicated with ® are registered brand names of respective manufactures.


204

» S-Series «

» S-Series «

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

Implant pick-up Open tray

Abutment screw

• incl.

• Titanium

retention screw steel

• Stainless

• Hex

Implant connection Version Article Number

D 3,5/4,0 short S 10

D 4,5/5,0 short S 11

1.26

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

205

grade 5 KV

Article Number

S 60

S 61

S 67

Article Number

S 60 L

S 61 L

S 67 L

Implant connection Article Number Abutment screw Laboratory screw

D 3,0 S 3530 S 67 S 67 L

D 3,5/4,0 S 3500 S 60 S 60 L

D 4,5/5,0 S 3520 S 61 S 61 L

D 3,5/4,0 S 3700 S 60 S 60 L

D 4,5/5,0 S 3720 S 61 S 61 L

D 3,5/4,0 1,5 5,2 S 110 S 60 S 60 L

D 4,5/5,0 1,5 6,0 S 120 S 61 S 61 L

Laboratory screw • red

coated

Implant pick-up Open tray • incl.

retention screw steel

• Stainless

Temporary abutment • Titanium

Implant connection Version Article Number

D 3,5/4,0 long S 20

D 4,5/5,0 long S 21

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 25 Ncm: D 3,5/4,0 25 Ncm: D 4,5/5,0 • incl.

Laboratory implant • Stainless

steel

Implant connection Article Number

D 3,0 S 53

D 3,5/4,0 S 50

D 4,5/5,0 S 52

Temporary abutment rotating • Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Laboratory implant CADCAM • Stainless

Implant connection Article Number Abutment screw Laboratory screw

steel

Implant connection D 3,0 D 3,5/4,0 Article Number S 83 S 80 Please note: This is used for 3D printmodels with Scanbody 2. generation.

D 4,5/5,0 S 82

Standard abutment straight • Titanium

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 25 Ncm: D 3,5/4,0 25 Ncm: D 4,5/5,0 • incl.

Placement instrument laboratory implant CADCAM • Stainless

steel

Implant connection Article Number

D 3,0 S 83 T

D 3,5/4,0 S 80 T

D 4,5/5,0 S 82 T

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

D 3,0 1,5 3,5 S 130 S 67 S 67 L

D 3,5/4,0 1,5 4,0 S 100 S 60 S 60 L


206

» S-Series «

» S-Series «

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

Standard abutment straight

Castable gold abutment rotating

• Titanium

• AU

grade 5 KV abutment screw • Recommended torque: 25 Ncm

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

207

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 25 Ncm

• incl.

• incl.

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

D 3,5/4,0 3,0 4,5 S 100-3 S 60 S 60 L

D 3,5/4,0 3,0 5,2 S 110-3 S 60 S 60 L

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

D 4,5/5,0 3,0 6,5 S 120-3 S 61 S 61 L

D 3,5/4,0 0,32 S 300 R S 60 S 60 L

D 4,5/5,0 0,90 S 320 R S 61 S 61 L

Solid abutment straight

Standard abutment angled 16°

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

• Titanium

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 25 Ncm: D 3,5/4,0 25 Ncm: D 4,5/5,0 • incl.

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

D 3,0 1,5 3,5 S 230 S 67 S 67 L

D 3,5/4,0 1,5 4,0 S 200 S 60 S 60 L

D 3,5/4,0 1,5 5,2 S 210 S 60 S 60 L

Implant connection D 3,5/4,0 D 4,5/5,0 Gingiva height (mm) 3,5 3,5 Diameter (mm) 5,0 6,0 Article Number S 400 S 420 Abutment screw S 60 S 61 Laboratory screw S 60 L S 61 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

D 4,5/5,0 1,5 6,0 S 220 S 61 S 61 L

Standard abutment angled 16°

Solid abutment angled 18°

• Titanium

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm

grade 5 KV abutment screw • Recommended torque: 25 Ncm

• incl.

• incl.

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

D 3,5/4,0 3,0 4,5 S 200-3 S 60 S 60 L

D 3,5/4,0 3,0 5,2 S 210-3 S 60 S 60 L

D 4,5/5,0 3,0 6,5 S 220-3 S 61 S 61 L

Implant connection D 3,5/4,0 Gingiva height (mm) 3,5 Diameter (mm) 5,0 Article Number S 500 Abutment screw S 60 Laboratory screw S 60 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

Castable gold abutment • AU

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 25 Ncm

D 4,5/5,0 3,5 6,0 S 520 S 61 S 61 L

POC abutment

• incl.

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

D 3,5/4,0 0,36 S 300 S 60 S 60 L

D 4,5/5,0 0,95 S 320 S 61 S 61 L

Implant connection D 3,5/4,0 Article Number S 900 Abutment screw S 60 Laboratory screw S 60 L Please note: For pressing on a individual ceramics Emergence profile.

D 4,5/5,0 S 920 S 61 S 61 L


208

» S-Series «

» S-Series «

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

Pulse opaque

Scanbody 1st Generation

• POC

• Peek

abutment

• incl.

Amount Article Number Please note:

• POC

209

retention screw

4 grams OP 90 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Pulse press blank

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

Implant connection Article Number Please note: This is used for Titanium base 1. generation.

D 3,5/4,0 S 00 W

D 4,5/5,0 S 20 W

Implant connection D 3,0 D 3,5/4,0 D 3,5/4,0 Chimney height 3.5 3.5 3.5 (mm) Gingiva height (mm) 0,6 0,6 1,1 Article Number S 1030 S 1000 S 1200 Abutment screw S 67 S 60 S 60 Laboratory screw S 67 L S 60 L S 60 L Please note: This is used with Scanbody 2. generation.

D 4,5/5,0 3.5

D 4,5/5,0 3.5

0,6 S 1020 S 61 S 61 L

1,1 S 1220 S 61 S 61 L

Implant connection D 3,0 D 3,5/4,0 D 3,5/4,0 Chimney height 5.5 5.5 5.5 (mm) Gingiva height (mm) 0,6 0,6 1,1 Article Number S 1130 S 1100 S 1300 Abutment screw S 67 S 60 S 60 Laboratory screw S 67 L S 60 L S 60 L Please note: This is used with Scanbody 2. generation.

D 4,5/5,0 5.5

D 4,5/5,0 5.5

0,6 S 1120 S 61 S 61 L

1,1 S 1320 S 61 S 61 L

Titanium base Zirconium abutment 2nd Generation

abutment

• Titanium

Colour Article Number Please note:

A3 B2 C2 D2 A2 P 90 P 91 P 92 P 93 P 94 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 25 Ncm: D 3,5/4,0 25 Ncm: D 4,5/5,0 • incl.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 1. generation.

D 3,5/4,0 4,0 0,8 S 800 S 60 S 60 L

D 4,5/5,0 4,0 0,85 S 820 S 61 S 61 L

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: Just for use with 3M ESPE Lava™.

D 3,5/4,0 4,0

D 4,5/5,0 4,0

0,8 S 800 LV S 60 S 60 L

0,85 S 820 LV S 61 S 61 L

Titanium base Zirconium abutment 2nd Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 25 Ncm: D 3,5/4,0 25 Ncm: D 4,5/5,0 • incl.


210

» S-Series «

» S-Series «

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

211

MedentiCAD abutment

Titanium base Bridges/ bars 2nd Generation

• Titanium

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 25 Ncm: D 3,5/4,0 25 Ncm: D 4,5/5,0 • incl.

• rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,5/4,0 3.5

D 4,5/5,0 3.5

0,6 S 1500 S 60 S 60 L

0,6 S 1520 S 61 S 61 L

Implant connection D 3,0 D 3,5/4,0 Article Number S 903001 S 900001 Abutment screw S 67 S 60 Laboratory screw S 67 L S 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 4,5/5,0 S 902001 S 61 S 61 L

Implant connection D 3,0 D 3,5/4,0 Article Number S 903004 S 900004 Abutment screw S 67 S 60 Laboratory screw S 67 L S 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 4,5/5,0 S 902004 S 61 S 61 L

Implant connection Article Number Please note: For use on the model only!

MedentiCAD abutment • CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 15 Ncm: D 3,0 25 Ncm: D 3,5/4,0 25 Ncm: D 4,5/5,0 • incl.

PreFace abutment ®

• Titanium

grade 5 KV abutment screw • Recommended torque: 15 Ncm: D 3,0 25 Ncm: D 3,5/4,0 25 Ncm: D 4,5/5,0 • incl.

Implant connection D 3,0 D 3,5/4,0 D 3,5/4,0 Diameter (mm) 11.5 11.5 16.0 Article Number S 9030-R S 9000-R S 9000-16R Abutment screw S 67 S 60 S 60 S 67 L S 60 L S 60 L Laboratory screw Please note: This is used with Scanbody 2. generation.

D 4,5/5,0 11.5 S 9020-R S 61 S 61 L

D 4,5/5,0 16.0 S 9020-16R S 61 S 61 L

MedentiCAD wax-up base • Steel • incl.

abutment screw

PreFace abutment ®

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 15 Ncm: D 3,0 25 Ncm: D 3,5/4,0 25 Ncm: D 4,5/5,0 • incl.

Implant connection D 3,0 Diameter (mm) 11.5 Article Number S 9830-R Abutment screw S 67 Laboratory screw S 67 L Please note: This is used with Scanbody 2. generation.

D 3,5/4,0 16.0 S 9800-16R S 60 S 60 L

D 4,5/5,0 16.0 S 9820-16R S 61 S 61 L

D 3,0 S 9130

D 3,5/4,0 S 9100

D 4,5/5,0 S 9120

D 3,5/4,0 2,5 S 4200

D 3,5/4,0 3,5 S 4300

D 3,5/4,0 4,5 S 4400

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 25 Ncm

• Recommended

Scanbody 2nd Generation Implant connection Gingiva height (mm) Article Number

• Titanium

grade 5 KV coated • incl. retention screw • specially

Implant connection D 3,0 D 3,5/4,0 Article Number S 1430 S 1400 Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 4,5/5,0 S 1420

D 3,5/4,0 0,5 S 4000

D 3,5/4,0 1,5 S 4100


212

» S-Series «

» S-Series «

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

MedentiBASE abutment straight • Titanium

MedentiBASE finisher • M

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head

grade 5 KV torque: 25 Ncm

• Recommended

Implant connection Gingiva height (mm) Article Number

D 4,5/5,0 0,5 S 4020

D 4,5/5,0 1,5 S 4120

D 4,5/5,0 2,5 S 4220

D 4,5/5,0 3,5 S 4320

D 4,5/5,0 4,5 S 4420

MedentiBASE prosthetic components 7600 MedentiBASE bridge screw Hex 1.26 • S 4700 MedentiBASE titanium cap incl. bridge screw • S 4710 MedentiBASE plastic cap incl. bridge screw • S 4720 MedentiBASE gold cap, castable incl. bridge screw • S 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

Article Number Please note:

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capS 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 25 Ncm • titanium

• S

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

S 7600

S 4700

S 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" S 4720

Implant connection D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number S 2000 S 2100 S 2200 S 2300 S 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

Titanium grade 5 KV S 4840

MedentiLOC abutment straight

MedentiBASE adhesive cap for passive-fit 4800 MedentiBASE adhesive cap Short incl. bridge screw • S 4810 MedentiBASE adhesive casing Short • S 4820 MedentiBASE adhesive cap Long incl. bridge screw • S 4830 MedentiBASE adhesive casing Long

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

• Titanium

grade 5 KV nitride coated • Recommended torque: 25 Ncm • titanium

• S

Version Article Number

Short S 4800

Short S 4810

Long S 4820

Long S 4830

Implant connection D 4,5/5,0 D 4,5/5,0 D 4,5/5,0 D 4,5/5,0 D 4,5/5,0 Gingiva height (mm) 1,5 2,5 3,5 4,5 5,5 Article Number S 2020 S 2120 S 2220 S 2320 S 2420 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

MedentiBASE scanbody MedentiLOC abutment angled 15°

• Titanium

grade 5 KV specially coated • incl. bridge screw

• Titanium

grade 5 KV nitride coated • incl. abutment screw • Recommended torque: 25 Ncm • titanium

Article Number Please note:

S 4900 The Scanbody is sterilisable and for intra-oral scanning.

Implant connection D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number S 2500 S 2600 S 2700 S 2800 S 2900 Abutment screw S 65 S 65 S 65 S 65 S 65 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

MedentiBASE accessories • M

11-6 Placement instrument MedentiBASE abutment • S 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

Article Number

S 4620

4630

M 11-6

80

213


214

» S-Series «

» S-Series «

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

Novaloc Processing package

Novaloc abutment straight

• Matrix

• Titanium

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

grade 5 KV coated • Recommended torque: 25 Ncm

Material Matrix housing Article Number Please note:

Titanium

Peek

Implant connection D 4,5/5,0 D 4,5/5,0 D 4,5/5,0 D 4,5/5,0 D 4,5/5,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number S 6020 S 6120 S 6220 S 6320 S 6420 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument MedentiLOC abutment, angled

Novaloc abutment angled 15°

• Hardened

• Titanium

Hex

stainless steel

grade 5 KV coated • incl. abutment screw • Recommended torque: 25 Ncm • LTC

Version Article Number

Contra-angle M 03-7

Manual and ratchet M 10-7

Implant connection D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number S 6500 S 6600 S 6700 S 6800 S 6900 Abutment screw S 68 S 68 S 68 S 68 S 68 Please note: To screw in the angled Novaloc abutments you need the special Placement instrument Ball-Torx M 03-8 or M 10-8.

MedentiLOC Laboratory implant • Stainless

215

• LTC

• Retention

• Ball

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

steel

Version Article Number

straight 56

angled 57

Novaloc Processing package • Matrix

Abutment screw MedentiLOC abutment, angled • Titanium • Ball

Hex

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert • Retention

grade 5 KV Article Number

S 65

Novaloc abutment straight

Placement instrument Novaloc abutment, angled

• Titanium

• Hardened

grade 5 KV coated • Recommended torque: 25 Ncm • LTC

• Ball

Material Matrix housing Article Number Please note:

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

stainless steel Torx®

Version Implant connection D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number S 6000 S 6100 S 6200 S 6300 S 6400 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Titanium

Article Number

Contra-angle M 03-8

Manual and ratchet M 10-8


216

» S-Series «

» S-Series «

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

Novaloc Laboratory implant

Placement instrument Optiloc abutment

• Stainless

• Hardened

steel

Version Article Number

straight 58

Version Article Number

• Aluminium

grade 5 KV Torx®

Article Number

S 68

Version Article Number

Optiloc abutment straight • Titanium

grade 5 KV coated • Recommended torque: 25 Ncm

4 piece 2102.0024

Planning abutment straight

• LTC

• Aluminium

red coated

Implant connection D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 D 3,5/4,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number S 5000 S 5100 S 5200 S 5300 S 5400 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Optiloc abutment straight

Implant connection Gingiva height (mm) Diameter (mm) Article Number

D 3,5/4,0 1,5/3,0 4,5 SP 100-3

D 3,5/4,0 1,5/3,0 5,2 SP 110-3

D 4,5/5,0 1,5/3,0 6,5 SP 120-3

Implant connection Gingiva height (mm) Diameter (mm) Article Number

D 3,5/4,0 1,5/3,0 4,5 SP 200-3

D 3,5/4,0 1,5/3,0 5,2 SP 210-3

D 4,5/5,0 1,5/3,0 6,5 SP 220-3

Planning abutment angled 18°

• Titanium

grade 5 KV • LTC coated • Recommended torque: 25 Ncm

• Aluminium

red coated

Implant connection D 4,5/5,0 D 4,5/5,0 D 4,5/5,0 D 4,5/5,0 D 4,5/5,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number S 5020 S 5120 S 5220 S 5320 S 5420 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Optiloc Processing package housing, titanium • Retention insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package

Manual and ratchet M 59

Optiloc implant analogue

• Titanium • Ball

217

stainless steel

angled 59

Abutment screw Novaloc abutment, angled

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

Planning abutment set • 6

• Matrix

Material Matrix housing Article Number Please note:

Titanium 5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.

piece

Article Number Content:

SPS SP 100-3, SP 110-3, SP 120-3, SP 200-3, SP 210-3, SP 220-3


218

» S-Series «

DENTSPLY Implants® ASTRA TECH OsseoSpeed TX®

Insert Processing holder prosthetic • Stainless

steel

Implant connection Article Number

D 3,0 S 43

Article Number

M 04

Processing holder, prosthetics • fits

all inserts steel

• Stainless

D 3,5/4,0 S 40

D 4,5/5,0 S 42


The T-Series abutments are compatible with

» T-SERIES «

DENTSPLY Implants® XiVE® S

DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments.

Type 1

Type 2

angled over flat

angled over corner

Products indicated with ® are registered brand names of respective manufactures.


222

» T-Series «

» T-Series «

DENTSPLY Implants® XiVE S®

Implant pick-up Open tray

Abutment screw

• incl.

• Titanium

retention screw steel

• Stainless

• Hex

Implant connection Version Article Number

D 3,4 short T 10

D 3,8 short T 15

D 4,5 short T 11

D 5,5 short T 12

1.2

DENTSPLY Implants® XiVE S®

223

grade 5 KV

Article Number

T 60

Article Number

T 60 L

Laboratory screw • red

coated

Implant pick-up Open tray • incl.

retention screw steel

• Stainless

Temporary abutment • Titanium

Implant connection Version Article Number

D 3,4 long T 20

D 3,8 long T 25

D 4,5 long T 21

D 5,5 long T 22

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Laboratory implant • Stainless

Implant connection Article Number Abutment screw Laboratory screw

steel

Implant connection Article Number

D 3,4 T 50

D 3,8 T 55

D 4,5 T 51

D 5,5 T 52

D 3,4 T 3500 T 60 T 60 L

D 3,8 T 3505 T 60 T 60 L

D 4,5 T 3510 T 60 T 60 L

Standard abutment straight • Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Laboratory implant CADCAM • Stainless

steel

Implant connection D 3,4 D 3,8 D 4,5 Article Number T 80 T 85 T 81 Please note: This is used for 3D printmodels with Scanbody 2. generation.

D 5,5 T 82

D 3,4 1,0 3,8 T 100-1 T 60 T 60 L

D 3,8 1,0 4,5 T 105-1 T 60 T 60 L

D 4,5 1,0 5,2 T 110-1 T 60 T 60 L

D 5,5 1,0 6,2 T 120-1 T 60 T 60 L

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

D 3,4 2,5 4,5 T 100 T 60 T 60 L

D 3,8 2,5 5,0 T 105 T 60 T 60 L

D 4,5 2,5 5,7 T 110 T 60 T 60 L

D 5,5 2,5 6,7 T 120 T 60 T 60 L

Standard abutment straight • Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm

Placement instrument laboratory implant CADCAM • Stainless

Implant connection Gingiva height (mm) Diameter (mm) Article Number Abutment screw Laboratory screw

• incl.

steel

Implant connection Article Number

D 3,4 T 80 T

D 3,8 T 85 T

D 4,5 T 81 T

D 5,5 T 82 T


224

» T-Series «

» T-Series «

DENTSPLY Implants® XiVE S®

Standard abutment angled 16°

Solid abutment straight

• Titanium

• incl.

grade 5 KV abutment screw • Recommended torque: 25 Ncm

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 25 Ncm Type 2

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

D 3,4 1,0 3,8 T 200-1-1 T 200-2-1 T 60 T 60 L

D 3,8 1,0 4,5 T 205-1-1 T 205-2-1 T 60 T 60 L

D 4,5 1,0 5,2 T 210-1-1 T 210-2-1 T 60 T 60 L

D 5,5 1,0 6,2 T 220-1-1 T 220-2-1 T 60 T 60 L

Standard abutment angled 16°

Solid abutment angled 18°

• Titanium

• Titanium

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 25 Ncm Type 2

Implant connection D 3,4 D 3,8 D 4,5 Gingiva height (mm) 3,5 3,5 3,5 Diameter (mm) 4,6 5,0 5,5 Article Number T 400 T 405 T 410 Abutment screw T 60 T 60 T 60 Laboratory screw T 60 L T 60 L T 60 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

D 5,5 3,5 6,5 T 420 T 60 T 60 L

Implant connection D 3,4 D 3,8 D 4,5 Gingiva height (mm) 3,5 3,5 3,5 Diameter (mm) 4,6 5,0 5,7 Article No. Type 1 T 500-1 T 505-1 T 510-1 Article No. Type 2 T 500-2 T 505-2 T 510-2 Abutment screw T 60 T 60 T 60 Laboratory screw T 60 L T 60 L T 60 L Please note: The Solid abutment will be delievered additional with Laboratory screw.

D 5,5 3,5 6,5 T 520-1 T 520-2 T 60 T 60 L

Implant connection D 3,4 D 3,8 D 4,5 Article Number T 900 T 905 T 910 Abutment screw T 60 T 60 T 60 Laboratory screw T 60 L T 60 L T 60 L Please note: For pressing on a individual ceramics Emergence profile.

D 5,5 T 920 T 60 T 60 L

grade 5 KV abutment screw • Type 1 = angled over flat • Type 2 = angled over corner • Recommended torque: 25 Ncm

• incl.

Type 1

225

• Titanium

• incl.

Type 1

DENTSPLY Implants® XiVE S®

• incl.

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2 Abutment screw Laboratory screw

D 3,4 2,5 4,5 T 200-1 T 200-2 T 60 T 60 L

D 3,8 2,5 5,0 T 205-1 T 205-2 T 60 T 60 L

D 4,5 2,5 5,7 T 210-1 T 210-2 T 60 T 60 L

D 5,5 2,5 6,7 T 220-1 T 220-2 T 60 T 60 L

Type 1

Type 2

Castable gold abutment • AU

60%; Pd 20%; Pt 19%; Ir 1% abutment screw • Recommended torque: 25 Ncm

POC abutment

• incl.

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

D 3,4 0,47 T 300 T 60 T 60 L

D 3,8 0,69 T 305 T 60 T 60 L

D 4,5 0,75 T 310 T 60 T 60 L

D 5,5 1,02 T 320 T 60 T 60 L

Castable gold abutment rotating

Pulse opaque

• AU

60%; Pd 20%; Pt 19%; Ir 1% • incl. abutment screw • Recommended torque: 25 Ncm

• POC

Implant connection Gold weight (g) Article Number Abutment screw Laboratory screw

D 3,4 0,38 T 300 R T 60 T 60 L

D 3,8 0,54 T 305 R T 60 T 60 L

D 4,5 0,60 T 310 R T 60 T 60 L

abutment

Amount Article Number Please note:

4 grams OP 90 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.


226

» T-Series «

» T-Series «

DENTSPLY Implants® XiVE S®

Pulse press blank • POC

DENTSPLY Implants® XiVE S®

227

Titanium base Zirconium abutment 2nd Generation

abutment

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Colour Article Number Please note:

A3 B2 C2 D2 A2 P 90 P 91 P 92 P 93 P 94 To achieve optimal results we do recommend to use the Press over Metal Ceramic available from Medentika.

Implant connection D 3,4 D 3,8 Chimney height 3.5 3.5 (mm) Gingiva height (mm) 0,3 0,3 Article Number T 1000 T 1005 Abutment screw T 60 T 60 Laboratory screw T 60 L T 60 L Please note: This is used with Scanbody 2. generation.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm

D 4,5 3.5

D 5,5 3.5

0,6 T 1010 T 60 T 60 L

0,6 T 1020 T 60 T 60 L

D 4,5 5.5

D 5,5 5.5

0,6 T 1110 T 60 T 60 L

0,6 T 1120 T 60 T 60 L

D 4,5 3.5

D 5,5 3.5

0,6 T 1510 T 60 T 60 L

0,6 T 1520 T 60 T 60 L

• incl.

Titanium base Zirconium abutment 2nd Generation Implant connection D 3,4 D 3,8 Chimney height 4,0 4,0 (mm) Gingiva height (mm) 0,3 0,3 Article Number T 800 T 805 Abutment screw T 60 T 60 T 60 L T 60 L Laboratory screw Please note: This is used with Scanbody 1. generation.

D 4,5 4,0

D 5,5 4,0

0,6 T 810 T 60 T 60 L

0,6 T 820 T 60 T 60 L

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection D 3,4 D 3,8 Chimney height 5.5 5.5 (mm) Gingiva height (mm) 0,3 0,3 Article Number T 1100 T 1105 Abutment screw T 60 T 60 Laboratory screw T 60 L T 60 L Please note: This is used with Scanbody 2. generation.

Titanium base Zirconium abutment 1st Generation • Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Titanium base Bridges/ bars 2nd Generation Implant connection D 3,4 Chimney height 4,0 (mm) Gingiva height (mm) 0,3 Article Number T 800 LV Abutment screw T 60 Laboratory screw T 60 L Please note: Just for use with 3M ESPE Lava™.

D 3,8 4,0 0,3 T 805 LV T 60 T 60 L

D 4,5 4,0 0,6 T 810 LV T 60 T 60 L

D 5,5 4,0 0,6 T 820 LV T 60 T 60 L

Scanbody 1 Generation st

• Peek • incl.

retention screw

Implant connection D 3,4 Article Number T 00 W Please note: This is used for Titanium base 1. generation.

D 3,8 T 05 W

D 4,5/5,5 T 10 W

• rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection D 3,4 D 3,8 Chimney height 3.5 3.5 (mm) Gingiva height (mm) 0,3 0,3 Article Number T 1500 T 1505 Abutment screw T 60 T 60 Laboratory screw T 60 L T 60 L Please note: This is used with Scanbody 2. generation.


228

» T-Series «

» T-Series «

DENTSPLY Implants® XiVE S®

PreFace® abutment

MedentiCAD abutment

• Titanium

• Titanium

DENTSPLY Implants® XiVE S®

229

grade 5 KV abutment screw • Recommended torque: 25 Ncm

grade 5 KV abutment screw • Recommended torque: 25 Ncm

• incl.

• incl.

Implant connection D 3,4 D 3,8 D 3,8 Diameter (mm) 11.5 11.5 16.0 Article Number T 9000-R T 9005-R T 9005-16R Abutment screw T 60 T 60 T 60 Laboratory screw T 60 L T 60 L T 60 L Please note: This is used with Scanbody 2. generation.

D 4,5 11.5 T 9010-R T 60 T 60 L

D 4,5 16.0 T 9010-16R T 60 T 60 L

Implant connection D 3,4 D 3,8 D 4,5 Article Number T 900001 T 900501 T 901001 Abutment screw T 60 T 60 T 60 Laboratory screw T 60 L T 60 L T 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,5 T 902001 T 60 T 60 L

Implant connection D 3,4 D 3,8 D 4,5 Article Number T 900004 T 900504 T 901004 Abutment screw T 60 T 60 T 60 Laboratory screw T 60 L T 60 L T 60 L Please note: Custom made abutment, will be created with Scanbody 2. generation.

D 5,5 T 902004 T 60 T 60 L

MedentiCAD abutment

PreFace® abutment

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 25 Ncm • incl.

• Titanium

grade 5 KV • incl. abutment screw • Recommended torque: 25 Ncm

Implant connection Diameter (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 5,5 16.0 T 9020-16R T 60 T 60 L

MedentiCAD wax-up base • Steel

PreFace® abutment

• incl.

abutment screw

• CrCo

alloy / CTE 14.1 abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection D 3,4 D 3,8 Diameter (mm) 11.5 16.0 Article Number T 9800-R T 9805-16R Abutment screw T 60 T 60 Laboratory screw T 60 L T 60 L Please note: This is used with Scanbody 2. generation.

D 4,5 16.0 T 9810-16R T 60 T 60 L

D 5,5 16.0 T 9820-16R T 60 T 60 L

Implant connection D 3,4 Article Number T 9100 Please note: For use on the model only!

D 3,8 T 9105

D 4,5 T 9110

D 5,5 T 9120

Implant connection Gingiva height (mm) Article Number

D 3,4 2,5 T 4200

D 3,4 3,5 T 4300

D 3,4 4,5 T 4400

MedentiBASE abutment straight • Titanium

grade 5 KV torque: 25 Ncm

• Recommended

Scanbody 2nd Generation • Titanium

grade 5 KV coated • incl. retention screw • specially

Implant connection D 3,4 D 3,8 Article Number T 1400 T 1405 Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 4,5/5,5 T 1410

D 3,4 0,5 T 4000

D 3,4 1,5 T 4100


230

» T-Series «

» T-Series «

DENTSPLY Implants® XiVE S®

MedentiBASE abutment straight • Titanium

231

MedentiBASE accessories • M

grade 5 KV torque: 25 Ncm

• Recommended

Implant connection Gingiva height (mm) Article Number

D 3,8 0,5 T 4005

D 3,8 1,5 T 4105

D 3,8 2,5 T 4205

D 3,8 3,5 T 4305

D 3,8 4,5 T 4405

11-6 Placement instrument MedentiBASE abutment • T 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

Article Number

T 4620

4630

M 11-6

80

MedentiBASE finisher • M

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head

MedentiBASE abutment straight • Titanium

DENTSPLY Implants® XiVE S®

grade 5 KV torque: 25 Ncm

• Recommended

Article Number Please note:

Implant connection Gingiva height (mm) Article Number

D 4,5 0,5 T 4010

D 4,5 1,5 T 4110

D 4,5 2,5 T 4210

D 4,5 3,5 T 4310

D 4,5 4,5 T 4410

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capT 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 25 Ncm • titanium

MedentiBASE prosthetic components • T

7600 MedentiBASE bridge screw Hex 1.2 • T 4700 MedentiBASE titanium cap incl. bridge screw • T 4710 MedentiBASE plastic cap incl. bridge screw • T 4720 MedentiBASE gold cap, castable incl. bridge screw • T 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

Material Article Number

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

T 7600

T 4700

T 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" T 4720

Titanium grade 5 KV T 4840

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 25 Ncm • titanium

MedentiBASE adhesive cap for passive-fit 4800 MedentiBASE adhesive cap Short incl. bridge screw • T 4810 MedentiBASE adhesive casing Short • T 4820 MedentiBASE adhesive cap Long incl. bridge screw • T 4830 MedentiBASE adhesive casing Long

Implant connection D 3,4 D 3,4 D 3,4 D 3,4 D 3,4 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 2000 T 2100 T 2200 T 2300 T 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• T

Version Article Number

Short T 4800

Short T 4810

Long T 4820

Long T 4830

MedentiBASE scanbody • Titanium

grade 5 KV specially coated • incl. bridge screw

Article Number Please note:

T 4900 The Scanbody is sterilisable and for intra-oral scanning.

Implant connection D 3,8 D 3,8 D 3,8 D 3,8 D 3,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 2005 T 2105 T 2205 T 2305 T 2405 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.


232

» T-Series «

DENTSPLY Implants® XiVE S®

» T-Series «

MedentiLOC abutment straight

MedentiLOC abutment angled 15°

• Titanium

• Titanium

grade 5 KV nitride coated • Recommended torque: 25 Ncm

• titanium

Implant connection D 4,5 D 4,5 D 4,5 D 4,5 D 4,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 2010 T 2110 T 2210 T 2310 T 2410 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

MedentiLOC abutment straight

Type 1

Implant connection D 4,5 D 4,5 D 4,5 D 4,5 D 4,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 2510-1 T 2610-1 T 2710-1 T 2810-1 T 2910-1 Abutment screw T 62 T 62 T 62 T 62 T 62 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

Novaloc Processing package

• Titanium

grade 5 KV nitride coated • Recommended torque: 25 Ncm • titanium

• Matrix

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert • Retention

Implant connection D 5,5 D 5,5 D 5,5 D 5,5 D 5,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 2020 T 2120 T 2220 T 2320 T 2420 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

MedentiLOC abutment angled 15°

Material Matrix housing Article Number Please note:

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument MedentiLOC abutment, angled

• Titanium

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 25 Ncm • titanium

233

grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 25 Ncm

• titanium

Type 1

DENTSPLY Implants® XiVE S®

• Hardened • Ball

Hex

stainless steel Version

Implant connection D 3,4 D 3,4 D 3,4 D 3,4 D 3,4 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 2500-1 T 2600-1 T 2700-1 T 2800-1 T 2900-1 Abutment screw T 62 T 62 T 62 T 62 T 62 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

Article Number

M 03-7

Manual and ratchet M 10-7

Version Article Number

straight 56

angled 57

MedentiLOC Laboratory implant • Stainless

steel

MedentiLOC abutment angled 15° grade 5 KV nitride coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 25 Ncm

Contra-angle

• Titanium • titanium

Type 1

Implant connection D 3,8 D 3,8 D 3,8 D 3,8 D 3,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 2505-1 T 2605-1 T 2705-1 T 2805-1 T 2905-1 Abutment screw T 62 T 62 T 62 T 62 T 62 Please note: To screw in the angled MedentiLOC abutments you need the special Placement instrument Ball-Hex 1,26 mm M 03-7 or M 10-7.

Abutment screw MedentiLOC abutment, angled • Titanium • Ball

Hex

grade 5 KV Article Number

T 62


234

» T-Series «

DENTSPLY Implants® XiVE S®

» T-Series «

Novaloc abutment straight

Novaloc abutment angled 15°

• Titanium

• Titanium

grade 5 KV coated • Recommended torque: 25 Ncm

DENTSPLY Implants® XiVE S®

235

grade 5 KV coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 25 Ncm

• LTC

• LTC

Implant connection D 3,4 D 3,4 D 3,4 D 3,4 D 3,4 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 6000 T 6100 T 6200 T 6300 T 6400 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Novaloc abutment straight

Type 1

Implant connection D 3,8 D 3,8 D 3,8 D 3,8 D 3,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 6505-1 T 6605-1 T 6705-1 T 6805-1 T 6905-1 Abutment screw T 63 T 63 T 63 T 63 T 63 Please note: To screw in the angled Novaloc abutments you need the special Placement instrument Ball-Torx M 03-8 or M 10-8.

Novaloc abutment angled 15°

• Titanium

grade 5 KV coated • Recommended torque: 25 Ncm • LTC

• Titanium

grade 5 KV coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 25 Ncm • LTC

Implant connection D 3,8 D 3,8 D 3,8 D 3,8 D 3,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 6005 T 6105 T 6205 T 6305 T 6405 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Novaloc abutment straight

Type 1

Implant connection D 4,5 D 4,5 D 4,5 D 4,5 D 4,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 6510-1 T 6610-1 T 6710-1 T 6810-1 T 6910-1 Abutment screw T 63 T 63 T 63 T 63 T 63 Please note: To screw in the angled Novaloc abutments you need the special Placement instrument Ball-Torx M 03-8 or M 10-8.

Novaloc Processing package

• Titanium

grade 5 KV • LTC coated • Recommended torque: 25 Ncm

• Matrix

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert • Retention

Implant connection D 4,5 D 4,5 D 4,5 D 4,5 D 4,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 6010 T 6110 T 6210 T 6310 T 6410 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

Novaloc abutment angled 15° grade 5 KV coated • incl. abutment screw • Type 1 = angled over flat • Recommended torque: 25 Ncm • LTC

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument Novaloc abutment, angled

• Titanium

Type 1

Material Matrix housing Article Number Please note:

• Hardened • Ball

Implant connection D 3,4 D 3,4 D 3,4 D 3,4 D 3,4 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 6500-1 T 6600-1 T 6700-1 T 6800-1 T 6900-1 Abutment screw T 63 T 63 T 63 T 63 T 63 Please note: To screw in the angled Novaloc abutments you need the special Placement instrument Ball-Torx M 03-8 or M 10-8.

stainless steel Torx®

Version Article Number

Contra-angle M 03-8

Manual and ratchet M 10-8


236

» T-Series «

» T-Series «

DENTSPLY Implants® XiVE S®

Novaloc Laboratory implant

Optiloc Processing package

• Stainless

• Matrix

steel

237

• Retention

Version Article Number

straight 58

angled 59

Abutment screw Novaloc abutment, angled • Titanium • Ball

housing, titanium insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package

DENTSPLY Implants® XiVE S®

grade 5 KV Torx®

Material Matrix housing Article Number Please note:

Titanium 5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument Optiloc abutment Article Number

T 63

• Hardened

stainless steel

Optiloc abutment straight

Version

• Titanium

grade 5 KV • LTC coated • Recommended torque: 25 Ncm

Manual and ratchet M 59

Article Number

Optiloc implant analogue • Aluminium

Implant connection D 3,4 D 3,4 D 3,4 D 3,4 D 3,4 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 5000 T 5100 T 5200 T 5300 T 5400 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Optiloc abutment straight

Version Article Number

4 piece 2102.0024

Planning abutment straight

• Titanium

grade 5 KV • LTC coated • Recommended torque: 25 Ncm

• Aluminium

red coated

Implant connection D 3,8 D 3,8 D 3,8 D 3,8 D 3,8 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 5005 T 5105 T 5205 T 5305 T 5405 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Optiloc abutment straight

Implant connection Gingiva height (mm) Diameter (mm) Article Number

D 3,4 1,0/2,5 4,5 TP 100

D 3,8 1,0/2,5 5,0 TP 105

D 4,5 1,0/2,5 5,7 TP 110

D 5,5 1,0/2,5 6,7 TP 120

Implant connection Gingiva height (mm) Diameter (mm) Article No. Type 1 Article No. Type 2

D 3,4 1,0/2,5 4,5 TP 200-1 TP 200-2

D 3,8 1,0/2,5 5,0 TP 205-1 TP 205-2

D 4,5 1,0/2,5 5,7 TP 210-1 TP 210-2

D 5,5 1,0/2,5 6,7 TP 220-1 TP 220-2

Planning abutment angled 18°

• Titanium

grade 5 KV coated • Recommended torque: 25 Ncm • LTC

• Aluminium

red coated 1 = angled over flat • Type 2 = angled over corner • Type

Type 1

Implant connection D 4,5 D 4,5 D 4,5 D 4,5 D 4,5 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number T 5010 T 5110 T 5210 T 5310 T 5410 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

Type 2


238

» T-Series «

DENTSPLY Implants® XiVE S®

Planning abutment set • 12

piece

Article Number Content:

TPS TP 100, TP 105, TP 110, TP 120, TP 200-1, TP 200-2, TP 205-1, TP 205-2, TP 210-1, TP 210-2, TP 220-1, TP 220-2

Insert Processing holder prosthetic • Stainless

steel

Implant connection Article Number

D 3,4 T 40

D 3,8 T 45

Processing holder, prosthetics • fits

all inserts steel

• Stainless

Article Number

M 04

D 4,5 T 41

D 5,5 T 42


The Y-Series abutments are compatible with

» Y-SERIES «

DENTSPLY Implants® ANKYLOS®

Products indicated with ® are registered brand names of respective manufactures.


242

» Y-Series «

» Y-Series «

DENTSPLY Implants® ANKYLOS®

Laboratory implant

Scanbody 2nd Generation

• Stainless

• Titanium

steel

grade 5 KV coated • incl. retention screw

D 3,5-7,0 Y 50

Abutment screw • Hex

1.0

243

• specially

Implant connection Article Number

• Titanium

DENTSPLY Implants® ANKYLOS®

Implant connection Article Number Please note: The Scanbody is sterilisable and for intra-oral scanning.

D 3,5-7,0 Y 1400

Implant connection Gingiva height (mm) Article Number

MedentiBASE abutment straight

grade 5 KV

• Titanium

grade 5 KV torque: 25 Ncm

• Recommended

Article Number

Y 61

Laboratory screw • red

coated

Article Number

Y 61 L

D 3,5-7,0 0,5 Y 4000

D 3,5-7,0 1,5 Y 4100

D 3,5-7,0 2,5 Y 4200

D 3,5-7,0 3,5 Y 4300

D 3,5-7,0 4,5 Y 4400

Titanium grade 5 KV

Titanium grade 5 KV

PMMA

Titanium grade 5 KV

Y 7600

Y 4700

Y 4710

"(AU 60%; Pd 20%; Pt 19%; Ir 1%)" Y 4720

Short Y 4800

Short Y 4810

Long Y 4820

Long Y 4830

MedentiBASE prosthetic components • Y

7600 MedentiBASE bridge screw Hex 1.0 • Y 4700 MedentiBASE titanium cap incl. bridge screw • Y 4710 MedentiBASE plastic cap incl. bridge screw • Y 4720 MedentiBASE gold cap, castable incl. bridge screw • Y 4840 MedentiBASE titanium base incl. bridge screw • Recommended torque: 15 Ncm

Titanium base Zirconium abutment 2nd Generation • rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm • incl.

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw Please note: This is used with Scanbody 2. generation.

D 3,5-7,0 3.5

D 3,5-7,0 3.5

0,65 Y 1500 Y 61 Y 61 L

1,15 Y 1700 Y 61 Y 61 L

Titanium base Zirconium abutment 2nd Generation

Material Article Number

Y 4840

MedentiBASE adhesive cap for passive-fit • Y

4800 MedentiBASE adhesive cap Short incl. bridge screw • Y 4810 MedentiBASE adhesive casing Short • Y 4820 MedentiBASE adhesive cap Long incl. bridge screw • Y 4830 MedentiBASE adhesive casing Long

Version Article Number

• rotating

• Titanium

grade 5 KV abutment screw • Recommended torque: 25 Ncm

MedentiBASE scanbody

• incl.

• Titanium

Implant connection Chimney height (mm) Gingiva height (mm) Article Number Abutment screw Laboratory screw

D 3,5-7,0 5.5

D 3,5-7,0 5.5

0,65 Y 1600 Y 61 Y 61 L

1,15 Y 1800 Y 61 Y 61 L

grade 5 KV specially coated • incl. bridge screw

Article Number Please note:

Y 4900 The Scanbody is sterilisable and for intra-oral scanning.


244

» Y-Series «

» Y-Series «

DENTSPLY Implants® ANKYLOS®

MedentiBASE accessories 11-6 Placement instrument MedentiBASE abutment • Y 4620 MedentiBASE implant pick up • 4630 MedentiBASE laboratory implant • 80 MedentiBASE laboratory implant CADCAM

• Titanium

grade 5 KV coated • Recommended torque: 25 Ncm • LTC

Article Number

Y 4620

4630

M 11-6

80 Implant connection D 3,5-7,0 D 3,5-7,0 D 3,5-7,0 D 3,5-7,0 D 3,5-7,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number Y 6000 Y 6100 Y 6200 Y 6300 Y 6400 Please note: To screw in the straight Novaloc abutments you need the original Placement instrument of the respective series.

MedentiBASE finisher • M

17 MedentiBASE finisher Connection geometry • M 18 MedentiBASE finisher Screw head

Novaloc Processing package Article Number Please note:

M 17 M 18 This is used to finish the fitting surfaces of the MedentiBASE plastic capY 4710after casting. The Finishers are used in the Processing holder prosthetic M 04.

MedentiLOC abutment straight • Titanium

grade 5 KV nitride coated • Recommended torque: 25 Ncm • titanium

Implant connection D 3,5-7,0 D 3,5-7,0 D 3,5-7,0 D 3,5-7,0 D 3,5-7,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number Y 2000 Y 2100 Y 2200 Y 2300 Y 2400 Please note: To screw in the straight MedentiLOC abutments you need the Placement instrument hex 1,26 mm M 03-1 or M 10-1.

• Matrix

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert • Retention

Material Matrix housing Article Number Please note:

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Novaloc Laboratory implant • Stainless

steel

Version Article Number

Novaloc Processing package

straight 58

Optiloc abutment straight

• Matrix

• Retention

• Titanium

grade 5 KV coated • Recommended torque: 25 Ncm • LTC

Material Matrix housing Article Number Please note:

Titanium

Peek

2010.601 2010.611 The entire product overview is available in section Novaloc®/Optiloc®.

Implant connection D 3,5-7,0 D 3,5-7,0 D 3,5-7,0 D 3,5-7,0 D 3,5-7,0 Gingiva height (mm) 1,0 2,0 3,0 4,0 5,0 Article Number Y 5000 Y 5100 Y 5200 Y 5300 Y 5400 Please note: To screw in the straight Optiloc abutments you need the special Placement instrument M 59.

MedentiLOC Laboratory implant • Stainless

245

Novaloc abutment straight

• M

housing, titanium/PEEK insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • incl. mounting insert

DENTSPLY Implants® ANKYLOS®

steel

Version Article Number

straight 56


246

» Y-Series «

DENTSPLY Implants® ANKYLOS®

Optiloc Processing package • Matrix

housing, titanium insert white Retention force: light • Retention insert yellow Retention force: medium • Retention insert green Retention force: strong • Mounting collar, silicone • 2 pcs per package • Retention

Material Matrix housing Article Number Please note:

Titanium 5202.0001 The entire product overview is available in section Novaloc®/Optiloc®.

Placement instrument Optiloc abutment • Hardened

stainless steel

Version Article Number

Manual and ratchet M 59

Optiloc implant analogue • Aluminium

Version Article Number

4 piece 2102.0024


» Novaloc «

» Optiloc «


250

» Novaloc « Picture

Part no.

Part description

» Optiloc « Specifications

Amount per package

2010.101

Novaloc® Equipment Box

Incl. 3 tools (without load)

2010.601

Novaloc Processing package titanium

• • • • •

Titanium matrix housing (1 pc) Retention insert white (1 pc) Retention insert yellow (1 pc) Retention insert green (1 pc) Mounting collar, silicone (1 pc)

2010.611

Novaloc Processing package PEEK

• • • • •

PEEK matrix housing (1 pc) Retention insert white (1 pc) Retention insert yellow (1 pc) Retention insert green (1 pc) Mounting collar, silicone (1 pc)

®

®

Picture

Part no.

Part description

Specifications

Amount per package

1 pc

5102.0000

Optiloc® Equipment Box

Incl. 3 tools Instrument brown 3202.0001 Instrument blue 3202.0002 Instrument grey 3202.0003 (without load)

2 pcs

5202.0001

Optiloc Processing package titanium

• • • • •

2102.0001

Optiloc® Matrix housing, titanium

Matrix housing: titanium

4 pcs

2102.0009

Optiloc® Matrix housing, elliptic

Titanium

4 pcs

Optiloc® Matrix housing, titanium with attachment option

Matrix housing: titanium

4 pcs

Optiloc® Retention insert red

PEEK Retention force:

extra-light

4 pcs

2102.0004

Optiloc® Retention insert white

PEEK Retention force:

light

4 pcs

2102.0005

Optiloc® Retention insert yellow

PEEK Retention force:

medium

4 pcs

2 pcs

2010.701

Novaloc® Matrix housing, titanium (incl. mounting insert)

Matrix housing: titanium Mounting insert: POM

4 pcs

2010.702

Novaloc® Matrix housing, titanium with attachment option (incl. mounting insert)

Matrix housing: PEEK Mounting insert: POM

4 pcs

special accessory

2102.0010 special accessory

2102.0003

®

1 pc

Titanium matrix housing Retention insert white Retention insert yellow Retention insert green Mounting collar, silicone

2 pcs

Novaloc® Matrix housing, PEEK (incl. mounting insert)

Matrix housing: titanium Mounting insert: POM

4 pcs

Novaloc® Retention insert red

PEEK Retention force:

extra-light

4 pcs

2102.0006

Optiloc® Retention insert green

PEEK Retention force:

strong

4 pcs

2010.711

Novaloc® Retention insert white

PEEK Retention force:

light

4 pcs

2102.0007

Optiloc® Retention insert blue

PEEK Retention force:

extra-strong

4 pcs

2010.712

Novaloc® Retention insert yellow

PEEK Retention force:

medium

4 pcs

special accessory

2102.0008

Optiloc® Retention insert black

PEEK Retention force:

ultra-strong

4 pcs

2010.713

Novaloc® Retention insert green

PEEK Retention force:

strong

4 pcs

2102.0024

Optiloc® Model analogue

Aluminium

4 pcs

2010.714

Novaloc® Retention insert blue

PEEK Retention force:

extra-strong

4 pcs

2102.0012

Optiloc® Forming / fixing matrix

PEEK

4 pcs

2010.715

Novaloc® Retention insert black

PEEK Retention force:

ultra-strong

4 pcs

2102.0023

Optiloc® Processing spacer

POM C

4 pcs

2010.721

Novaloc® Model analogue

Aluminium

4 pcs

2102.0011

Optiloc® Mounting collar, silicone

Silicone

10 pcs

2010.722

Novaloc® Forming / fixing matrix

PEEK

4 pcs 3202.0002

Aluminium, steel

1 pc

2010.723

Novaloc® Processing spacer, white

Optiloc® Model analogue reposition aid + Laboratory placement instrument blue

2010.724

Novaloc® Mounting collar, silicone

Silicone

10 pcs

3202.0001

Optiloc® Mounting and demounting tool forretention inserts (brown)

Aluminium, steel

1 pc

2010.725

Novaloc® Mounting insert

PEEK

4 pcs

3202.0003

Optiloc® Matrix housing extractor

Aluminium, steel

1 pc

2010.731

Novaloc® Demounting tool for mounting inserts + model analogue reposition aid (blue)

Aluminium, steel

1 pc

2010.741

Novaloc® Mounting and demounting tool forretention inserts (brown)

Aluminium, steel

1 pc

2010.751

Novaloc® Matrix housing extractor (grey)

Aluminium, steel

1 pc

special accessory

2010.703 special accessory

2010.710

special accessory

POM C

4 pcs


» Tools «


254

» Tools «

» Tools «

Placement instrument Hex 1.26 • Hardened

Placement instrument UG • Hardened

Type Article Number Suitable for:

Contra-angle

Contra-angle

Manual and Manual and ratchet ratchet long short long short M 03-1 M 09-1 M 10-1 M 11-1 BS-Series, C-Series, D-Series, EV-Series, I-Series, R-Series, S-Series, Medentiloc abutment straight

Version Type Article Number Suitable for:

stainless steel

• Hardened • Ball

Version Type Article Number Suitable for:

Contra-angle long M 03-2 T-Series, H-Series

Contra-angle short M 09-2

Manual and ratchet long M 10-2

Manual and ratchet short M 11-2

Contra-angle

Manual and ratchet long M 10-5

long short M 03-5 M 09-5 E-Series, F-Series, K-Series

Manual and ratchet short M 11-5

Hex

stainless steel Version Article Number

Contra-angle M 03-7

Manual and ratchet M 10-7

Version Article Number

Contra-angle M 03-8

Manual and ratchet M 10-8

Placement instrument Novaloc abutment, angled • Hardened

Placement instrument Hex 1.0

• Ball

stainless steel Torx®

stainless steel

Version Type Article Number Suitable for:

Contra-angle long M 03-3 Y-Series

Contra-angle short M 09-3

Manual and ratchet long M 10-3

Manual and ratchet short M 11-3

Placement instrument Optiloc abutment • Hardened

stainless steel

Placement instrument Torx® T6 • Hardened

Contra-angle

Placement instrument MedentiLOC abutment, angled

Placement instrument Hex 1.2

• Hardened

stainless steel

stainless steel

Version

• Hardened

255

stainless steel

Version Article Number

Manual and ratchet M 59

Version Type Article Number

Manual and ratchet 2-piece M 11-6

Article Number

M 12

Placement instrument MedentiBASE abutment Version Type Article Number Suitable for:

Contra-angle

Contra-angle

long short M 03-4 M 09-4 B-Series, L-Series, N-Series

Manual and ratchet long M 10-4

Manual and ratchet short M 11-4

• Stainless

steel

Torque ratchet • with

infinitely variable torque setting • 10-40 Ncm • Hardened stainless steel


256

» Tools «

» Tools «

Adapter • Ratchet

257

Screw channel block-out pin Titanium base

M12 stainless steel

• Hardened

• Aluminium

Article Number

M 14

Altus gingiva gauge

Article Number

2013.901

Version Article Number Suitable for:

black coated M 05-2 B 1000, B 1100, B 1500, D 1000, D 1010, D 1100, D 1110, D 1200, D 1210, D 1300, D 1310, D 1500, D 1510, F 1100, F 1200, F 1300, F 1500, F 800, F 1000, L 1000, L 1010, L 1100, L 1110, L 1500, L 1510, L 801, L 811, S 1100, S 1200, S 1300, S 1500, S 800, S 1000

Version Article Number Suitable for:

red coated M 05-3 BS 1010 - BS 1030, BS 1110 - BS 1130, BS 1510, BS 1520, S 1020, S 1220, S 1120, S 1320, S 1520, S 820

Version Article Number Suitable for:

yellow coated M 05-4 CX 1000, CX 1100, CX 1200, CX 1300, CX 1500, E 1000 - E 1030, E 1100 - E 1130, E 1500 - E 1520, E 800 - E 830, F 1110, F 1210, F 1310, F 1510, F 810, F 1010, I 1000 - I 1020, I 1100 - I 1120, I 1500 - I 1520, I 800 - I 820, K 1110, K 1510, K 810, K 1010, N 1010, N 1020, N 1110, N 1120, N 1510, N 1520, N 810, N 820, R 1000 - R 1020, R 1100 - R 1120, R 1500 - R 1520, R 800 - R 820

Version Article Number Suitable for:

green coated M 05-5 EV 1020 - EV 1040, EV 1120 - EV 1140, EV 1220 - EV 1240, EV 1320 - EV 1340

Screw channel block-out pin Titanium base • Aluminium

Processing holder, prosthetics • fits

all inserts • Stainless steel

Article Number

M 04

MedentiBASE finisher Connection geometry • Tungsten

Screw channel block-out pin Titanium base • Aluminium

carbide

Version Article Number Please note:

Connection geometry Screw head Connection geometry M 17 M 18 M 19 This is used to finish the fitting surfaces of the MedentiBASE plastic cap4710after casting. For the MedentiBASE plastic cap N 4710 the Finisher M 19 is required. The Finishers are used in the Processing holder prosthetic M 04.

Screw channel block-out pin Titanium base

Screw channel block-out pin Titanium base

• Aluminium

• Aluminium

Version Article Number Suitable for:

blue coated M 05-1 C 1000 - C 1020, C 1100 - C 1120, C 1500 - C 1520, C 1500 - C 1520, EV 1000, EV 1010, EV 1100, EV 1110, EV 1200, EV 1210, EV 1300, EV 1310, H 1000 - H 1020, H 1100 - H 1120, H 1500 - H 1520, H 800 - H 820, K 1100, K 1500, K 800, K 1000, N 1100, N 800, N 1000, S 1030, S 1130, S 1530, T 1000 - T 1020, T 1100 - T 1120, T 1500 - T 1520, T 800 - T 820

Screw channel block-out pin Titanium base • Aluminium

Version Article Number Suitable for:

grey coated M 05-6 C 1030, C 1040, C 1130, C 1140


258

» Tools « Wooden tool box Placement instrument Manual and ratchet • without

contents Article Number

MB 02

Wooden tool box Placement instrument Manual and ratchet

Version Article Number Content:

long MB 04K M 10-1, M 10-2, M 10-3, M 10-4, M 10-5

Version Article Number Content:

short MB 05K M 11-1, M 11-2, M 11-3, M 11-4, M 11-5

Article Number Content:

MB 05 Processing holder prosthetic M 04 and Allen key

Wooden tool box Placement instrument Manual and ratchet

Wooden tool box Processing holder prosthetic

Compartment box Abutments and scanbodys • 30

compartments

• Polystyrene

Version Article Number

without contents MB 04


260

261

DISTRIBUTED BY INSTRADENT UK ORDERING AND DELIVERY

WARRANTY PROGRAM FOR OUR ABUTMENTS IN COMBINATION WITH IMPLANTS OF OTHER MANUFACTURERS Warranty conditions

Orders received before 14:00 hrs will usually be shipped on the same day. In the event of a national holiday, your order will be shipped on the next working day.

We provide you with an extended warranty on our components when used with implants from other implant companies. The extended warranty program covers your costs of our abutments and the material costs of the respective implant (when used in combination), in the case that a failure occurs after healing and the implant company refuses to cover the costs of the implant, because it was combined with our components.

Instradent UK is not responsible for lost or stolen packages. All lost or stolen packages need to be handled by the customer and the respective shipping agency.

This warranty is valid for as long as the stated warranty of the respective implant company, but for a maximum of 30 years from delivery. This warranty cannot be connected with any other warranty and is not a prolongation to any existing warranty.

DHL or Royal Mail delivery services will normally be used. Other shipping options are available, please contact customer service for current pricing and availability.

No warranty shall be granted:

Contact Customer service at +44 (0) 1293 560777 for ordering, shipping and general enquiries.

Please note that catalogue prices may be subject to change.

RETURNS/EXCHANGES Medentika agrees to exchange or return articles under the following conditions: • Only unopened goods in perfect condition shall be accepted with postage paid and with a copy of the receipt

enclosed.

• In the case of non-sterile articles a voucher/return is only possible if the goods are returned to Instradent USA, Inc.

within 3 months of the date of the receipt. The goods must be unopened.

• In the case of sterile goods, goods may only be exchanged free-of-charge if they are unopened and there is at least

12 months until the expiry date.

• Sterile products may not be exchanged or returned if the packaging has been opened.

LIMITED COMPREHENSIVE WARRANTY FOR OUR PRODUCTS Warranty conditions MEDENTIKA offers a limited warranty for their implant products. We will provide the replacement of our products without additional costs if they reveal material or manufacturing defects or they do not comply with our quality standards. The warranty period for our products is 30 (thirty) years from delivery. We offer a 10 year warranty (from date of delivery) on all our Novaloc® and Optiloc® abutments. For MedentiLOC abutments we offer a warranty of 3 (three) years. All Novaloc® housings and matrices are not covered by warranty as they are subject to natural wear. This voluntary warranty is supplementary to the warranty rights defined by law and the product liability and does not affect these. In addition, our General Terms and Conditions of Sale shall apply. The assignment of rights from this limited comprehensive warranty requires the consent of Medentika.

In the case of immediate restorations • For damage of other products or the implants due to external impacts such as accidents or comparable events and incorrect treatment • Failure of implants from different providers, such as material or manufacturing defects. • For failure of our products or the implants in the case of contraindications such as alcoholism, diabetes or drug • addiction • For further claims and consequential damages such as laboratory costs or the costs of clinical and/or dental treatment. • If an implant fails and the original manufacturer will not honor their warranty because of the use of a Medentika part, Medentika will honor the original implant manufacturer’s warranty. The lab or Dr. must present the original implant warranty in writing, and must show evidence that the original warranty claim was not approved. The reimbursement of the case will be in the form of a free replacement abutment, free replacement screw, and a check for the cost of the implant alone. The clinical cost in removing, replacing, and restoring the implant site will be the sole responsibility of the Lab, Dr., or patient. This voluntary guarantee is supplementary to the warranty rights defined by law and the product liability and does not affect these. In addition, our General Terms and Conditions of Sale shall apply. The assignment of rights from this warranty requires our consent. In case of a warranty claim, please contact us and request the respective forms and documentation Instradent UK 3 Pegasus Place Gatwick Road Crawley West Sussex RH10 9AY john.aiken@instradent.com Office: +44 (0) 1293 560777 info.uk@instradent.com www.instradent.co.uk/en/medentika.html Medentika may modify or terminate their warranty program at any given time. Any amendment or termination of the warranty does not affect products which have been used prior to the date of the modification or termination of the Warranty Program.

MANUALS / IFU You can find the manuals of our products under www.medentika.de/en/ifu.

GENERAL TERMS AND CONDITIONS OF BUSINESS Please refer to: www.instradent.uk/medentika


262

263

IMPRINT Editor:

Medentika GmbH Hammweg 8–10 76549 Hügelsheim +49 (0)7229 69912-0 +49 (0)7229 69912-20 info@medentika.de www.medentika.de

Design by:

Der WeberFink GbR Graphic Design Studio www.weberfink.de

As at: January 2016

Products indicated with

®

are registered brand names of respective manufactures.

Novaloc ® and their components are manufactured by: Valoc AG Bahnhofstrasse 64 CH-4313 Möhlin Tel: +41 61 855 95 59 Mail: info@valoc.ch


Medentika is distributed by: Instradent UK 3 Pegasus Place Gatwick Road Crawley West Sussex RH10 9AY Office: +44 (0) 1293 560777

» Passion for Precision «

PM_01_00001_2A_EN


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.