CAD Details Future Roof Shingle

Page 1

SHINGLE

FULL INTERLOCKING SIDELAP

FULL INTERLOCKING HEADLAP

FULL INTERLOCKING BASELAP

BUILT IN NAIL TAB 1/8" STAMPED STEP FOR EXTRA STRENGTH AND MOISTURE DIVERSION

NAILING TAB

FULL INTERLOCKING SIDELAP

DIMENSIONS: 8.625" X 17.375" EXPOSED 0.375" BUTT EDGE SHINGLE PROFILE 9.44" X 18.12" OVERALL

CLOSEUP OF FULL INTERLOCKING SIDELAP

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_SHINGLE_A

SECTION: 1 PAGE


STARTER & RAKE (10 FT.)

0.5" 0.375"

30°

1.125"

1.0"

30°

1.0"

90° 1.25"

0.625"

40° 0.5"

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_START_A

SECTION: 1 PAGE


STARTER DETAIL

MININUM PITCH: 3 IN 12

DEPTH OF EACH COURSE TO WEATHER 8.625"

INTERLOCKING WEATHER-PROOF "S" LOCK DESIGN

UNDERLAYMENT SHEATHING RAFTER

STARTER STRIP

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_START_D

SECTION: 1 PAGE


VALLEY (10 FT.)

4.0"

1.0"

4.75 "

20°

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_VAL_A

SECTION: 1 PAGE


VALLEY DETAIL

SHINGLE VALLEY EACH SHINGLE IS BENT TO FIT INTERLOCKING SIDE LAP

FASCIA

STARTER STRIP

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_VAL_D

SECTION: 1 PAGE


GABLE END OR RAKE DETAIL

GABLE & STARTER

SHINGLE

FASCIA

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_GARA_D

SECTION: 1 PAGE


HIGH PROFILE HIP & RIDGE SHINGLE TRIM

FASTENING APRON

1.75"

4.0"

11.0"

1.0" .75" INTERLOCKING NOSE END TAB

5.0"

REAR INTERLOCKING SIDE LAP

7.5" 1.0"

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_HIPRISHINTRIM_A

SECTION: 1 PAGE


HIP DETAIL

SHINGLE MITERED AND OVERLAPPED AT THE HIP, MINIMUM 2"

FASCIA

1.0" 0.5"

Hip Starter is made by cutting the top of the shingle hip and ridge back approximately 1.5". With the bending tool form the interlocking nose end tabs at 90° approximately 1.0" above bend again at 90° to complete the hip starter. The interlocking nose end tabs fit under the starter strip nose end . Pull back and fasten.

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_HIP_D

SECTION: 1 PAGE


OVAL, GAMBREL & RIDGE

WEATHER SEALED LOCKING JOINT

8.625" TO WEATHER

OVAL DETAIL

RAFTER

8.625" TO WEATHER

8.625" TO WEATHER

UNDERLAYMENT RAFTER SHEATHING RAFTER

GAMBREL DETAIL

RIDGE DETAIL

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_OVGAMRI_D

SECTION: 1 PAGE


COLLAR (10 FT.)

0.5" 1.0"

7.0"

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_COL_A

SECTION: 1 PAGE


ENDWALL & SIDEWALL (10 FT.)

4.0"

0.75"

1.0"

1.75"

0.875" 2.625"

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_ENDWLSIDWL_A

SECTION: 1 PAGE


PIPE FLASHING

FASTENERS NOSE END OF SHINGLE CUT TO FIT AROUND BACK OF PIPE JACK CONE

FELT OVERLAY

EXPOSED FRONT OF PIPE JACK

.5" BENDBACK WATER DIVERTERS

FELT OVERLAY

PIPE JACK CONE PIPE JACK APRON

SHINGLE

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_PIPFL_D

SECTION: 1 PAGE


END & SIDE WALL DETAIL

NAILING CLIP ATTACHED TO THE LOCKING CLIP OF THE CUT SHINGLE

THE TOP EDGE OF THE CUT SHINGLE IS INSERTED INTO THE ENDWALL FLASHING. SIDE & ENDWALL FLASHING

NAIL TAB OF BOTTOM SHINGLE

FUTURE ROOF SYSTEMS R

9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_ENDSIDWAL_D

SECTION: 1 PAGE