SHINGLE
FULL INTERLOCKING SIDELAP
FULL INTERLOCKING HEADLAP
FULL INTERLOCKING BASELAP
BUILT IN NAIL TAB 1/8" STAMPED STEP FOR EXTRA STRENGTH AND MOISTURE DIVERSION
NAILING TAB
FULL INTERLOCKING SIDELAP
DIMENSIONS: 8.625" X 17.375" EXPOSED 0.375" BUTT EDGE SHINGLE PROFILE 9.44" X 18.12" OVERALL
CLOSEUP OF FULL INTERLOCKING SIDELAP
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_SHINGLE_A
SECTION: 1 PAGE
STARTER & RAKE (10 FT.)
0.5" 0.375"
30°
1.125"
1.0"
30°
1.0"
90° 1.25"
0.625"
40° 0.5"
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_START_A
SECTION: 1 PAGE
STARTER DETAIL
MININUM PITCH: 3 IN 12
DEPTH OF EACH COURSE TO WEATHER 8.625"
INTERLOCKING WEATHER-PROOF "S" LOCK DESIGN
UNDERLAYMENT SHEATHING RAFTER
STARTER STRIP
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_START_D
SECTION: 1 PAGE
VALLEY (10 FT.)
4.0"
1.0"
4.75 "
20°
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_VAL_A
SECTION: 1 PAGE
VALLEY DETAIL
SHINGLE VALLEY EACH SHINGLE IS BENT TO FIT INTERLOCKING SIDE LAP
FASCIA
STARTER STRIP
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_VAL_D
SECTION: 1 PAGE
GABLE END OR RAKE DETAIL
GABLE & STARTER
SHINGLE
FASCIA
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_GARA_D
SECTION: 1 PAGE
HIGH PROFILE HIP & RIDGE SHINGLE TRIM
FASTENING APRON
1.75"
4.0"
11.0"
1.0" .75" INTERLOCKING NOSE END TAB
5.0"
REAR INTERLOCKING SIDE LAP
7.5" 1.0"
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_HIPRISHINTRIM_A
SECTION: 1 PAGE
HIP DETAIL
SHINGLE MITERED AND OVERLAPPED AT THE HIP, MINIMUM 2"
FASCIA
1.0" 0.5"
Hip Starter is made by cutting the top of the shingle hip and ridge back approximately 1.5". With the bending tool form the interlocking nose end tabs at 90° approximately 1.0" above bend again at 90° to complete the hip starter. The interlocking nose end tabs fit under the starter strip nose end . Pull back and fasten.
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_HIP_D
SECTION: 1 PAGE
OVAL, GAMBREL & RIDGE
WEATHER SEALED LOCKING JOINT
8.625" TO WEATHER
OVAL DETAIL
RAFTER
8.625" TO WEATHER
8.625" TO WEATHER
UNDERLAYMENT RAFTER SHEATHING RAFTER
GAMBREL DETAIL
RIDGE DETAIL
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_OVGAMRI_D
SECTION: 1 PAGE
COLLAR (10 FT.)
0.5" 1.0"
7.0"
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_COL_A
SECTION: 1 PAGE
ENDWALL & SIDEWALL (10 FT.)
4.0"
0.75"
1.0"
1.75"
0.875" 2.625"
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_ENDWLSIDWL_A
SECTION: 1 PAGE
PIPE FLASHING
FASTENERS NOSE END OF SHINGLE CUT TO FIT AROUND BACK OF PIPE JACK CONE
FELT OVERLAY
EXPOSED FRONT OF PIPE JACK
.5" BENDBACK WATER DIVERTERS
FELT OVERLAY
PIPE JACK CONE PIPE JACK APRON
SHINGLE
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_PIPFL_D
SECTION: 1 PAGE
END & SIDE WALL DETAIL
NAILING CLIP ATTACHED TO THE LOCKING CLIP OF THE CUT SHINGLE
THE TOP EDGE OF THE CUT SHINGLE IS INSERTED INTO THE ENDWALL FLASHING. SIDE & ENDWALL FLASHING
NAIL TAB OF BOTTOM SHINGLE
FUTURE ROOF SYSTEMS R
9969 RIVER WAY DELTA, B.C. CANADA V4G 1M8 DATE: JUNE 2003 FILE: AS_ENDSIDWAL_D
SECTION: 1 PAGE