Detalii utilizatori - Panasil - Kettenbach - Iris CT Dental

Page 1

020482_3108 AWB PIC Light

10.09.2008

8:27 Uhr

Seite 3

USER REPORT 12.07 P A N A S I L® I N I T I A L

C O N TAC T

L I G H T

Hubert Christian Roggendorf, D.D.S.

“gold standard” among impression materials. The hydrophilicity of many A-Silicones – achieved by

Department of Prosthodontics, Propaedeutics and Dental Materials Center of Dento-Maxillo-Facial Medicine, Rheinische Friedrich-Wilhelms University of Bonn

adding tensides – also eliminates, to a large extent, the hydrophobic nature of silicone. This “hydrophilization” takes sufficient effect usually only some time after the mixing or even after the setting. Often, as a result, the tensides are still not active even during the

A-Silicones, due to their high degree of refinement and a clearly low contraction behavior compared to condensation-curing products, are currently still considered the

injection of the impression material. With Panasil® initial contact light, Kettenbach Company, one of a few privately owned dental companies in Germany, has succeeded in

TRUE TO DETAIL

The combination of Panasil® tray soft and Panasil® initial contact light – an effective alternative within the double-mix technique

PA N A S I L ® I N I T I A L C O N TA C T L I G H T


020482_3108 AWB PIC Light

10.09.2008

8:27 Uhr

Seite 4

USER

REPORT

P A N A S I L® I N I T I A L

C O N TAC T

offering a modern wash material

precision

impression

that, due to its initial hydrophilicity,

onlays,

allows high-precision impressions

crowns and bridges. A high initial

in borderline cases, in which

hydrophilicity and excellent flowa-

polyethers were otherwise mostly

bility of Panasil® initial contact light

used as an alternative.

immediately after the application

partial

of

inlays,

crowns,

single

L I G H T

allow – with the optimally adjusted Panasil initial contact light, in

viscosity of Panasil® tray soft – a

combination with Panasil® tray soft,

precise impression of sulcus areas

is especially suitable for the double-

with a certain residual moisture. A

mix technique. The use of both

good

materials together creates a clean,

material also prevents the materials

uniform wetting of infragingival

from running over the edges of the

preparation areas. This is due to

tray.

®

thixotropy

of

light-body

high flowability and low viscosity of and

In terms of working time, the

sufficiently high dynamic pressure

effectiveness of Panasil® initial

of the tray material. This makes the

contact light is clearly convincing.

combination of both materials

The

optimal for the impression of dental

insertion of the tray into the

preparations with supragingival to

patient’s mouth, easy removal of

infragingival preparation borders. In

retraction threads from the sulcus

addition the low degree of final

area, and easy application on

hardness of Panasil tray soft also

prepared teeth. With regard to the

makes the removal of the tray

time sitting in the mouth, the

easier

polyether

assessment by patients and dentists

impressions, and thus makes the

was equally positive. With an

product combination very patient-

intraoral working time of 1 minute,

and user-friendly.

the total time in the mouth was

the

light-body

material

®

compared

to

product

allows

Fig. 1: Initial situation with VMK Crown 12

an

Fig. 2: Situs after removal of a crown

easy

Fig. 3: Post-prepared tooth

2 minutes, 30 seconds, considered The aim of Kettenbach’s research department was to provide a light-

comfortably short and proving to be

Fig. 4: Situs after preparation

efficient for daily use.

body material that accommodates the putty-wash technique as well as

As with all A-Silicones, when

the increased use of double-mix

using Panasil® products it should be

impressions. Combining light-body

taken into account that certain

and carrier material resulted in

types of gloves, such as latex

more than equal effectiveness for

gloves, can damage the catalyst.

the demands of an efficient high-

This applies to both direct and

Fig. 5: Tray preparation with Panasil® Haftlack/adhesive varnish


10.09.2008

8:28 Uhr

Seite 5

USER

REPORT

P A N A S I L® I N I T I A L

C O N TAC T

L I G H T

Fig. 11: Application of preparation with Panasil® initial contact light

Fig. 16: Removal of Provisional crown

Fig. 7: Visual check

Fig. 12: Inserted tray

Fig. 17: Cercon crown filled with cement

Fig. 8: Tray filling with Panasil® tray soft

Fig. 13: Detailed view of the preparation

Fig. 18: Cementing of Cercon crown

Fig. 9: Application of Panasil® initial contact light

Fig. 14: Futar® D – bite taking

Fig. 19: Cemented Cercon crown

Fig. 10: Removal of retraction threads

Fig. 15: Futar® D – bite registration material

PANASIL

®

Fig. 6: Check without Dynamic Mixer

INITIAL CONTACT LIGHT

020482_3108 AWB PIC Light


020482_3108 AWB PIC Light

10.09.2008

8:27 Uhr

Seite 2

USER REPORT 12.07 P A N A S I L® I N I T I A L

C O N TAC T

L I G H T

indirect glove contact. Therefore,

by dentists. The examination of the

is offered in three different pack

gloves

for

finished dental prosthesis – both on

sizes:

compatibility by applying a sample

a model and on a tooth stump –

1, 2 and 6 x 300 ml Base as well as a

of the impression material on the

confirmed optimal detail precision

62 ml catalyst paste.

glove. Incompatible gloves produce

and dimension accuracy of the

a smeared layer.

impression material.

should

be

tested

Panasil® initial contact light also

The application of Panasil® initial

offers a particularly suitable color.

contact light is carried out using a

The contrast range for the double-

mixing gun. The pack sizes are

mix technique proved to be highly

available in user-convenient 2 x 50 ml

favorable by dentists and patients.

or 12 x 50 ml cartridges. Panasil®

The

also

tray soft is available in the currently

good

common tubular bag for electric

readability and was also approved

dispensing and mixing devices and

color

provided

combination particularly

SUMMARY The combination of Panasil® tray soft and Panasil

wash impression, on the other

initial

hand, Panasil® initial contact

contact light proved to have

X-light is preferable, which, due

optimal effectiveness for dental

to its comparative even lower

patients. The positive properties

viscosity, assures a comprehen-

of both materials bode well for

sive impression of wash areas.

this combination – especially

The optimal dynamic pressure

for the impression of supra-

should

gingival to infragingival prepa-

provided by a putty material. It

rations. Both materials are also

should be noted that with

completely suitable for the

Panasil® initial contact light,

KETTENBACH GmbH & Co. KG

increasingly preferred double-

the Kettenbach Company has

Im Heerfeld 7 35713 Eschenburg/Germany Telefon: +49 (0) 27 74 / 7 05- 0 Telefax: +49 (0) 27 74 / 7 05- 33 E-mail: info@kettenbach.com www.kettenbach.com

mix technique. A good inflow of

succeeded in providing an

light-body materials into gaps

excellent alternative to the

is

much-used polyethers.

facilitated

by

mutually

then

be

preferably

adjusted viscosities. For the

020482_3708

For further information, contact:

®


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.