Leicester, United Kingdom 07516484794 Januszmoore@hotmail.com
PORTFOLIO
JANUSZ MOORE
CONTE NT
ACADEMIC 1. RUINCARNATION THESIS DESIGN PROJECT
2. THE RECONSTRUCTED VILLAGE RESEARCH & DESIGN PROJECT
3. THRESHOLD STUDIO PROJECT
THE PORTFOLIO This portfolio consists of a combination of academic and professional works which best represent my skills and their application within various contexts.
PROFESSIONAL 5. DUDLEY GARDENS NEW-BUILD DWELLING
6. FISHER ROW RETROFIT PROJECT
7. ESSEX STREET HMO DEVELOPMENT
8. PATMORE ESTATE FEASIBILITY STUDY & COLLABORATIVE REGENERATION PROJECT
PHOTOGRAPHY
Ruincarnation looks to the UK’s rust belt as a new avenue for cohabitation and explores key challenges that come when dealing with historical sites subject to dereliction. What are the processes necessary to transform these sites in order to revive the industrial roots and forgotten communities that ground them? How should we respond to material decay in order to highlight issues of finiteness and celebrate historical value whilst developing sustainable systems for development?
ACADEMIC
ACADEMIC
THE PROJECT
RIBA SILVER AWARD NOMINATION ARCHITECTS’ JOURNAL STUDENT PRIZE NOMINATION
RUINCARNATION INDUSTRIAL TRANSFORMATION
MA2 THESIS DESIGN PROJECT 2021
Public Space Axonometrtic
Phase I Site Axonometric
Phase II Site Axonometric
Phase III Site Axonometric
Isometric Site Section
The Seed Bank Archive
Site Plan & Elevation Hybrid
The Whitfield Museum
ACADEMIC
THE PROJECT Informed by studies of morphosis & deconstructivism, The Reconstructivist City is home to an autonomous society taking back their right to the city through the formation of a new urban typology. Using the formal principals of retro-kit, a designed system for urban rehabilitation, this new typology latches onto the existing urban fabric and transforms it from within to provide the future neighbourhoods of the city.
THE RECONSTRUCTED VILLAGE AUTONOMOUS COMMUNITY HOUSING
MA1 PRIMARY RESEARCH AND DESIGN PROJECT 2020
Day Time Axonometric
Night Time Axonometric
Southern Entrance
Isometric Section
Southern Piazza
Bicycle Highway
Northern Piazza
The Workshop
Longitudinal Section
ACADEMIC
RIBA BRONZE AWARD NOMINATION
THE PROJECT The final design project within my undergraduate studies was a creative hub based in central London. Established along the border between Hackney and Islington, once recognised as the artist commune of the capital, now subject to significant gentrification. Threshold reinstates the artist community, providing spaces for young creatives to live, work and teach. Finetuned spaces create opportunities to make and exhibit across multiple disciplines whilst cohabitating under the same roof.
THRESHOLD CREATIVE HUB
BA3 PRIMARY STUDIO PROJECT 2018
Longitudinal Section
Internal Studio Views
Exploded Axonometric
First Floor Plan
PROFESSIONAL
THE PROJECT Dudley Gardens involved the demolition of a derelict terrace house and subsequent rebuild of a contemporary replacement with notable reference to the character of the existing. The site constraints presented several unique challenges, fronting a single footpath and backing onto the Cherwell River, requiring a number of comprehensive studies regarding access and ecological concerns. Dudley Gardens has provided me with an extensive understanding of each stage of procurement from the initial site survey to the final working drawings.
DUDLEY GARDENS NEW-BUILD DWELLING
2019 - 2020
0 No
tes
:
1
Ground Floor Plan 1715_001
2
ts ll d ca isc le r e pa sh from nc ou ies ld this Th is m be c dra dr co ust b hec win aw mm e ke g. ing r A d e is nc epo on ll d C em rte sit im or opy en d to e p ens us rig to io r ed ht f th the ior t ns wit pro e a Arc o c are ho te a ff hit on u c p e s t c pr ted ted ect f truc pro ior an wo or v tion xima wr d m e . r t it r k e t s en ust an . ifica d pe no tio rm t to np is rio sio be rt n rep o ro du ce d
5m
N
n t o n n ina Dw ail ll co new and spec tract sible ge C to wn g 1 02 ru 39 Ge nne dr cov tion or t for n 1_ fit ner ction aina er le cha o ch the C.3 05 co ted al n s t ge vels mb eck de r o o e n rs, pos sign fir to th te: be uns . me e a dr itio of in t ain n a d o dra non ac o ex M c ag s o ll t in n H RW er fa sit ag retu orda erna Flo P e s rn n e un ll c l fo or s, ys tem valv e wit ul w Ty Ex pe , lo e is h P ate sli istin 1 ca to b art r s din g t t H e im g io N nt e o. th e win doo be ob r 1F res ish ho dow rs by scre e e ld er w sch Sp n t Ro it Ex w h s edu ecia o be lot le. list re wh istin dr New sup mo ere g m GX S.D ain D.1 req aso op plie ved. D 0 en r in Ne uir nry in e w t e d g o Ex to xist gla be is ha ing zed t r ing eta ve o ine bo lev pen un da el ing Ne da nd , ry loc w in rep wa atio sp air ll e c n e No d Ne to tion .2 be c wa w lo Fis co ham rep Exis he inf ll, s w le nf S.F lac tin e rR irm ber g th orm e e vel Ne F RW ow ed sho Int ed w bric P L N e e at lev op in w i w io e v D e r n i rain ex pos w xpre n. atio enin na ith b k w n in B N n a is t lo g ll g s C d r o ll s y s t o w ing slo ica ile dr ick t tak De GF Roo lev con wo and to b rF tiv yli bo t an el sen rks win e fo lue th ely ne o m en d .07 m Dw tail un d b ro win t d a atc ow to , r d W g 1 06 da ox ug wall to B do of t be ow med nd h n e r h 3 . rem all T y e x h 9 w s m u t D f wa 1_ im 1 W trac inis xist and ain w in e S nd che in e o yp a C ll in h t b W g t t t .3 o o gr ved e 2. 13 Det all hed g. pe ruct erta dule xistin 04 pr taine min er fr ere b thro ou an Ex Ex 91 ail nin ura ken fo g Ty as e a u d o u HW _C 02 pe r lE g do istin nd f d re istin to serv . In tes me li iler gh e .30 ng with 4 tim e in tum fire nin flu xt pr or t g en loor plac g st 5 in ou e p ern t a b r g e e e e e s ba opo o be tran d w ir w t a c es r eg r. t a rrie sed re ce wit dry rity ent istan o wa sse l Co ith ing B r in lo fur to h a lin of f co ce ll 3 s GW ran ntra fac to Ne De oile pp ing ire llar to 0 clu cat bis be ing be w Be ge cto 06 sig r t to b r a d io he re b in p o o m r e t E r b v n o ick d n w d a loca ng to ed ac rote flu e ric ; re be Bin be to fo ine Str ith nd wo kw t do cor ctio e er' uc fer par Be relo rm Ex de re ed. s s tura sta sto rk or cu dan n P am t is p t E r m k o o e E b ir c m li c l ng to uil ate nich pa ess ca rage ou used xist me ting pr f C en ce ine Str to se ing ov on nt d h e in er' uc tB to rt o uris to pla vau Be s s tura ab in isio tra ff am f C ed p e b p e lt s s l le r r e E e t x t o na cto e c ng to a e S.A is vis ont hot GX fo flo rte r ed c ine Str tin l s r's rm A od er' uctu eil D.0 rb um gw all iona ract wat ss ed ing ars Ne ow l 6 pe ral or e J.0 s all c be M Be w 6 ret .E fo sum 's D r tan lo am H b a r x e E s k r Ex w 2 is in w ick ng to 75 tin ist ed ate Con sign to ine Str wo 4 ing g er' uctu an r c tra ; re be ss rk Ex d on ct fe pe ral w b R c r a W u W ne or r rem istin e ll t ilt pa P all ctio to o o ir pe ov g sta T f b ed fs yp ns er tar e Co r Lis ed a irs in Di eta lin 4, ter nin ine sto ntra ted nd s to b ed ex S.C ba d C as istin 13 rag cto Buil alva e ca rs r GF g Ar pe g Un 91_C e of res ding ged refu GX r f wa .0 e N D in 3 a 6 tw der .30 stair pon Co for lly e 14 .11 ish lls t w es o b op sta o la side 1 fo tim sible nsen re-u sc e d se En wa enin min gge yers of s r de ber for t. he as du ry to gine ll in g t De Ex wit ute red of p tairs tails s. Se safe Be le be er ac o b ed a h A s f join las to . Dw tail re istin 115 En m to u s d co e ir t 0 t c r n 0 p g f r a e o g ine Str pr e p ts to erbo be t Do aine g re win 13 4 W nse dert sign dan orm er' uc ov ro r s s tura Ex all c e 91 g en or a d, r ar d ed tec pro ard eate pe l s t nt o aken an e w d in _C RW o t c n e w t C ist v d d in D f it o .3 P o De ranc d fa pair or a oc ion ide ith wit be the wit spe h S exis 05 fir ntra g fir um in e t nli ed nd W 6 h dr St hou c. tru tin Dw tail 54 all o F gh an fa en acc 0 N y li ruc t c wo epla ctor epla g g 1 12 Ty t B or lat t to d r nlig 9 c ne tu the o w tura rks ce pe da 39 . ra th to e e to 3 d b efu ht ex ork l E n 1 l 4 n r a e x _ o c , s C.3 e us rbis to b ug sur be r ex p Engin pres s t istin h o e e is e h 0 r d t ou e pr etain be g p 2 Ex fin e s ing at ed. Lin +1 11 is t t ote e ret art te sc ish er. 50 wa En l to he 50 ctio d. an ting he es ain itio gin S ll c tr in du s e e o G Dra J.0 sta d re floo to d nw ur n o XD er's suctura le in all se f 1 be ll D cor r to .07 pec l Ex D sa GW of d PM d e be Ex nd rec istin 27 ist lin ry 05 an xistin ret op 0 ing ed Fla an ord g flo d r g ain 12 en d r ex or wa t1 59 e- st ed J.0 in 9 e is la ll g 5 s s lay tin to b y in one . Lif to 8 in g st e re be Co o flag t or on ta Co cu 7 po rigin s, mm igin e in +1 Lin tb n sit al 5 te a fla ed x tr 0 a e ion a E 6 l is S ng l to x po gs, . Lif tin cto ist ck t t un . GX ineer'Structu sit ins t a ing o w 5 GF airs al ur g flo r to Co ion tall nd D.0 s sp ral e op ide c n e . . c 0 D 8 4 en n 5m safe or b aref 8 PM wa tract ing m st oa ull ll in or Dw 3 join to flo bat orag rds a y rem g1 D or ten e e En acc fo 2 39 eta d nd ov th ry to gine ord rm 1_ il 0 wit joist s fix urin skir e is C.3 4 1 e lo be ers anc nic t h s h c 0 K ov va to f d to g wo ing atio salv inst e w e in 5 itc po it an e r e n a age ruct ith S ex d kir r. Ex ur Roc xist ks. GF hen Se s p d ion tru istin tin ist pe kw in .05 er and s. E ctu g IC aled ns g t ing rme oo g L o r x in is f ha be timb able l loo ted refit istin al r d r r e- er f +3 Bu ted g ish wir Ex laid lo 10 he isti ed ex Co ildin in ng at ist in or ns g Be a ing am en Dra S.D de nd s re in t do tain tec m B D or Ex ed to ok , to is e r t Str ing il a uc tura 30 pa n lE L/s rtit nt d ng rac ine er' to ion w ss an tor wid a pe ne to d ll c w e n e s to ior to b w x t is o 83 e GD tin e cu l ra 8 I B n x go tb .0 il 1 t e 98 5 Be dr pe ack ho erm J.0 1 a nin o En m to 2 wit b to itte gin S GF om g 30 S.F h A b nt m ee tru 91 r's ctu .02 2 F pp e m ec sp ral Dra ec Ba ro in. ha in A v n t 3 I e ic h 0 d pa nter D L/ al e GF room rtit na ha ro ocu s in xtra io l P rd .0 m u a n a ct t c w 4 e e w ith to rtitio ire to nt F cord ove sm SV d Ro bat n be . D an r ok Pck hr ty A c u c e p o o w E d nf ctin e xis oo om e 2 et irm g e c re b tin Ap l in to b , tim to ed a r b 1 p C ta ric g e r k c 5 in o L/s nt ed wor eces rove cor full er st rac , r y k s u d d J.0 to efu . Exis to b Do ance fille d 3 r r d c Re to m bish ting e inf ume with fer join ille nt ak ed ex a e d E t n o is g tin pr oo d re ery t with ex Int ov ist g erm Ha isio d all loca o be ing ted f n in it r G J.0 Ap ad a ten F.0 ll 4 iat pr sa l sum ishe . ov min t m nit s or 3 ed . 1 ec ary s fo GD Do 5 L han wa r S .A N c re .0 um /s in ical A 1 Ex ew en ac ext is st t F co rac ref ting one GW . D rd t ur jo b to uc anc to in ste E is x Es 01 ist he ery ps in be ting e w be Ex ing W cap d, it t ist ind e se o be new conf rou h in re jo e irm te o in g o r jo w he fire furb ery ine etain pen ed igh pla ish to in ry ac e b t sc ed a g c he nd ins cord 100 of f e to d, se e re du ta t a m ir e b e r u le ctio nce m b pla e re spe ined ns with elow ce t tain cific an GD ex o .N B at d e is S c .0 b d e t e 2 ing d w truc eilin e ra . He ion ro b tu g is a Ex G om b asin ral he ed d is e t F in fit and Eng ight to .01 1 ted pr re g fir in f m in ot ta an use in irr eers ec ine epla d m bo fir or GX tio d ce ep to ete x D.0 n o . Co an lac Co r f f nt d h 1 e ir r n a e e c a nu trac t pla to rt t h m o e c ce t r to h to du +1 r rin skir ber e to ou hro en be 70 g w tin xis car rse ug su re t g e Fla o o ex ork and ting fully f w hou t s. is R flo or t p 1 ks tim erm ock ting 25x ensu or remo be ea woo tim 25m re bo ve r f ble l in be m sa ard an loo m s r s d b fe r b em ula floo atte sto and re oa br tion r jo ns rag e C x o ist laid rds ane wit ists fixe e nt ing a s ra in nd ove h va to f d Al rad Co GF.0 alva ctor or skir r. E po it ld igin tin xis u iat n 1 ge to ra S.E or to trac Be co car g tin r al wi E loc to g p ex tor dro rnic efu n la a g tio be ste istin to fix om e w lly r s g ns r up 1 an he emo En to b o to a ceil ceil 2.5 d G re v GW gin e re pe n co n a ing ing, mm F.0 exist e an m ss to r ex in d ee ad p 3 Es 02 d the me ess be ist las Ha g in rs i f n loo raw List nce men ret ing terb llwa W cap d ind e ra con r b ing ed me t o aine lath oa y. ow rd wi uil 13 Bu nt f it d e d ng junc 91 ild of s c su an Re s a tio tain rein up. E _C.3 ing the ond bjec d sta xis 07 Co wo itio t nd n w Ex n t t r a an n f n is d d f d re ed b ing c or n sent ks a eta ith to tin s . f e e r g a me urbis low ornic w p See ils Stru sk be sk s n sa irtin reta irtin ,s he ctu ew e to arty fe ee x in g g is , b c ra p d ro and ed. dad oo ting eilin e l tec C o g r s do tio corn ontr rail ch RW n p ice ac an ed ors P ule rio an tor d c t o rt d e o r rn o r ein nsur emo ice sta e t ve tem heir en t
4
-
Drawn By
Checked By
Building Regs
SH
TB
0
1
2
3 4 River Cherwell
N
3
Revision
Stage
September 2019
3
4 5m
Date
71
2
Drawing Number
Connect to existing - location & invert tbc
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction.
5m
North (Rear) Elevation
Notes:
21
1
N
0
S.AA
Notes: This drawing is Copyright protected and must not to be reproduced or used without prior written permission All discrepancies must be reported to the Architect for verification prior to Dudley Gardens commencement of the affected works.
This drawing is Copyright protected and must not to be reproduced or used without prior written permission
Scale 1:50 @ A3
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement of the affected works.
New foul water drain run min 1:80
Ground Floor Plan
+250
4 Dudley Gardens
GW 02
51
Project
3440
144 114
244
144
762x1981mm
1122
2040
3100
1850
100 762x1981mm
1089 100
2015
1500
762x1981mm
4412
2552 600
ist
in
South (Front) Elevation
ex
4412
or
iat
Workshop
gr ad
211
n
2200
Standing seam zinc cladding
3 Dudley Gardens
828
rad
37
SW 01
30 L/s
Intermittent mechanical extract over hob to be min. 30 L/s in accordance with Approved Document F. Ducting route to be confirmed
DW 1800
ew
828
5
97
77
FW 03
400
20
3100
11
2200
iat or
Dark grey self coloured render
10
Be a En m to gin S ee tru r's ctu sp ral ec
FW 04
38
S.BB
1
582
Tel:01865 553772
Storage tank for sprinkler system, refer to sepcification
WM
15 L/s
21
114
www.riacharchitects.com
Company Number: 8867519
77
mail@riacharchitects.com
65 Banbury Rd, Oxford, OX2 6PE.
Riach Architects Limited,
Be a En m to gin S ee tru r's ctu sp ral ec
6 L/s
1749
Utility GF.03
Intermittent mechanical extract to be min. 15 L/s in accordance with Approved Document F. Ducting route to be confirmed
1749 1094
heat and smoke detector hard wired
Oven 1200
FF
GD.04
10 8
828
C/O Agent Client
879
GD.02
2
11
New surface water drain routed under building to drain directly through existing boundary wall into the River Cherwell
3920 238
WC GF.02 1749
JOISTS OVER
hard wired GD.03 842
2100
Lin En tel to gin S ee tru r's ctu sp ral ec
Drawing title
Paving laid to fall towards drains Fall
Bin Store
709
GW 01
RWP
Fall
Intermittent mechanical extract to be min. 6 L/s in accordance with Approved Document F. Ducting route to be confirmed
GXD.01 672
GD.01
Entrance Hall GF.01
S.BB
smoke detector 1883
UP
1 Mopstick handrail
3 4 5 6
Kitchen GF.04
7 8
Cupboard -
762x1600mm
Rendered wall to bike store
8653
Gr
Dr
aw i
ou
te
Ri a 65 ch A ma Ban rchit i l @ bury ects ria Cl ien ch Rd, Limi t ar ch Oxfo ed, Mo t ite rd C c t r s. , OX om r e c Pr p 2 o lls m oje 6P any ct E. Fa Nu m ww rm Fis w. Tel: ber: i n 0 r 8 h i 1 a 86 8 6 rch 5 5 751 ite 537 9 cts 7 .co 2 m
ng
nd
us
e
t2
titl
e
gL td
er R
ow
Flo o
rP
0
lan
114
Au g
ag
144
ch a
144
INARY
PRELIM
lim
N
1006
ng
938
wi
2440
Dr a
114
1
St
Pr e
1
1006
Ex Ex ist re istin in f u rb g win As g RW is s h ed dow um P to as s t ed b pe o b bou e re rw e t n ind reta dar aine ow in y li d sc ed a ne an hed nd d s ule pe c.
Da
RL 01
_C
938
Sedum blanket on waterproof membrane
Dark grey self coloured render Zinc fascia 1079
39 1
2440
879
Hardwood fascia
1079
FW 01
1500
606
2944
New surface water inspection chamber
in
19
S
ar
um b
ca le
1:5
ies
er
.20
T
Dr
3
0@
aw
A2
nB
S/ S
y
H
Ch
TB
Standing seam zinc cladding
Workshop
3 Dudley Gardens
Re
ec
ke
dB
Notes:
y
vis
-
This drawing is Copyright protected and must not to be reproduced or used without prior written permission
2082
Hardwood posts on stainless steel footings
Workshop
GXD.01
1350
955 3732
3 Dudley Gardens
JOISTS OVER
Living / Dining GF.05
GW 01
JOISTS OVER
3440
GW 02
RWP 976
Existing building demolished S.AA
Riverbank wall to be replaced
ion
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement of the affected works.
or used without prior written permission
Notes:
S.BB
Ridge line to match neighbouring ridge
18mm WISA plywood
Detail XX Dwg 1715_C.XXX
Detail XX Dwg 1715_C.XXX
18mm WISA plywood 150
147mm roof joists to structural engineers spec.
120mm Insulation Vapor barrier
Box gutter fixed to standing seam zinc on timber facia 2250
Bedroom 2 FF.01
18mm Carrier plywood
15mm plaster board with skim finish
Detail XX Dwg 1715_C.XXX
Ridge beam to structural engineers spec. TOS tbc.
20mm self-colour render on mesh 18mm plywood
248
11
Stair dims 13x192mm rise 227mm going 40 deg Ensure 2m clear headroom above FD.02
TBC
Wall type A
15mm plaster board with skim finish
Title
Scale
Detail
Eaves Detail A
1 : 10
01
2250
Bedroom 1 GF.03
Title
Scale
Detail
Ridge Detail A
1 : 10
02
2000
40°
Landing GF.03
Detail XX Dwg 1715_C.XXX
Floor type B 248
Aluminium frame window - spec tbc.
Kitchen GF.04
Riach Architects Limited,
Living / Dining GF.05
Company Number: 8867519
65 Banbury Rd, Oxford, OX2 6PE. mail@riacharchitects.com
GD.04
Tel:01865 553772
www.riacharchitects.com
40°
C/O Agent Detail XX Dwg 1715_C.XXX
600
170mm Insulation between rafters to structural engineers spec.
4 Dudley Gardens
25mm batten
600
September 2019
Section A-A
S.BB
Building Regs
This drawing is Copyright protected and must not to be reproduced or used without prior written permission
S.AA
Notes:
Drawn By
Checked By
SH
TB Revision
-
Title
Scale
Detail
Terrace Detail A
1 : 10
03
6mm Standing seam zinc on DELTA TRELA
Polyroof 185C System as manufacturers specification or similar approved
18mm external grade WBP plywood (spruce board).
18mm external grade WBP plywood (spruce board).
Insulation spec TBC
Zinc verge
Vapor control layer 25mm insulation between horizontal timber battens 15mm plaster board with skim finish
FD.03
Study FF.01
18mm plywood 170mm insulation between vertical timber joists to structural engineers spec.
Title
Scale
Detail
Eaves Detail C
1 : 10
01
SH
1715_201
This drawing is Copyright protected and must not to b or used without prior written permission
Box gutter mechanically fixed to standing seam zinc on timber facia
Insulation spec TBC
Zinc fascia 18mm external grade WBP plywood (spruce board).
Wall type A
12.5 mm plasterboard with taped and scrimmed joints. Skimmed and painted colour TBC.
Drawn By
Notes:
18mm external grade WBP plywood (spruce board).
20mm self-colour render on mesh
Stage
Building Regs Drawing Number
Polyroof edge trim
Firrings with minimum 25mm thickness laid to 1 in 80 fall
150x50mm flat roof joists at 400mm centres to SE design and spec.
Scale 1:10 @ A3
Do not scale from this drawing. All dimensions are app should be checked on site prior to construct All discrepancies must be reported to the Architect for ve commencement of the affected works.
Vapour control layer
Firrings with minimum 25mm thickness laid to 1 in 80 fall
Floor type B
Date
September 2019
15mm plaster board with skim finish
Drawing Number
Wall type C
Drawing title
Proposed Details 01
25mm insulation between horizontal timber battens
Scale 1:50 @ A3
18mm external grade WBP plywood (spruce board).
En-Suite FF.02
4 Dudley Gardens
18mm plywood
Vapour control layer
Bedroom 2 FF.01
Project
170mm insulation between vertical timber joists to structural engineers spec.
1715_104
Detail XX Dwg 1715_C.XXX
C/O Agent
20mm self-colour render on mesh
Section A-A
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement of theStage affected works.
Tel:01
www.riacharc
Client
Steel to structural engineers spec. (offset 75mm from vertical steel post)
Steel to structural engineers spec.
Date
Company Numb
65 Banbury Rd, Oxford, OX2 6PE.
20mm thick polypropylene plate within render
15mm plaster board with skim finish
Drawing title
Riach Architects Limited, mail@riacharchitects.com
147mm roof joists to structural engineers spec.
18mm Chipboard
Project
Polyroof 18mm WISA plywood 120mm Insulation Aluminium coping on timber carcassing to connect with polyroof to ensure that insulation is fully encapsulated Vapor barrier 18mm carrier plywood Furring batten - 25mm to 15mm
Timber skirting board Allow 22mm for floor finish
Client
Floor type A
100
170mm insulation between vertical timber joists to structural engineers spec. 25mm insulation between horizontal timber battens 15mm plaster board with skim finish
150
2573
Entrance Hall GF.01
Powder-coated steel balustrade
Cill board
Stair dims 14x184mm rise 220mm going 40deg Ensure 2m clear headroom
2325
GW 01
147mm roof joists to structural engineers spec. 25mm battens
15mm plaster board with skim finish Vapour Control Layer - Spec TBC
9
2498
Study FF.01
147mm roof joists to structural engineers spec.
25mm insulation between horizontal timber battens
10
Detail XX Dwg 1715_C.XXX
Furring batten - 100mm to 25mm
170mm insulation between vertical timber joists to structural engineers spec.
Floor type B
Notes:
Timber fillet
Vapor barrier 18mm Carrier plywood
1
This drawing is Copyright protected and must not to b or used without prior written permission
Polyroof
120mm Insulation
4 56
Do not scale from this drawing. All dimensions are app should be checked on site prior to construct All discrepancies must be reported to the Architect for ve commencement of the affected works.
6mm Standing seam zinc on DELTA TRELA
Drip 150x50mm flat roof joists at 400mm centres. 12.5 mm plasterboard with taped and scrimmed joints. Skimmed and painted colour TBC.
Title
Scale
Detail
Eaves Detail B
1 : 10
02
to allow light and precipitation to pass through
Detail XX Dwg 1715_C.XXX Floor type B
Allow 22mm for floor finish 65mm sand cement screed 500 Gauge polythene sheet
Entrance Hall GF.01
Utility GF.03
facing brickwork below DPC Specification TBC
100mm Insulation - spec TBC
Wall type B
140mm concrete blockwork
Riach Architects Limited,
Floor type A
Company Number: 8867519
65 Banbury Rd, Oxford, OX2 6PE.
Detail XX Dwg 1715_C.XXX
mail@riacharchitects.com
225mm RC Slab to structural engineer's design and specification
Workshop
0
1
2
Drawing title
Proposed Details 02
y
in
Drawing title
4 Dudley Gardens
600
Date
September 2019
Section B-B
3
Section B-B
Pr el im
S.AA
N
3 Dudley Gardens
Notes:
Project
ar
4 Dudley Gardens
This drawing is Copyright protected and must not to be reproduced or used without prior written permission
C/O Agent
Reinforced concrete foundations to Structural Engineer's design and specification.
Client
Date
4
5m
September 2019
Scale 1:50 @ A3
Stage
Drawn By
Building Regs
SH
Drawing Number
Checked By
TB Revision
Tel:01
www.riacharc
Client
Pea shingle channel around perimeter
Tel:01865 553772
C/O Agent
Company Numb
65 Banbury Rd, Oxford, OX2 6PE. mail@riacharchitects.com
www.riacharchitects.com
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement ofProject the affected works.
Riach Architects Limited,
Lean mix at base of cavity
Vapour Control Layer
GD.03
Title
Scale
Detail
Foundation Detail A
1 : 10
03
Scale 1:10 @ A3
Stage
Drawn By
Building Regs
SH
Drawing Number
1715_202
PROFESSIONAL
THE PROJECT Fisher Row was a contemporary response to an existing Victorian townhouse. Working from materials and elements of the dwelling, the brief required a rear extension and renovation to the existing structure. Fisher Row was one example of a project involving works to a listed or historically significant structure. This is an area which greatly interests me and inspired much of my academic studies.
FISHER ROW RETROFIT PROJECT
2019 - 2020
New brick dwarf wall built to 1m with oak CB timber fence over to 2m
S.BB
No. 1 Fisher Row
S.EE
No. 2 Fisher Row
Existing brick wall taken down and replaced with brick to match existing. Internally drylined and finished as Wall Type 4
Detail 02 Dwg 1391_C.305 Existing inspection chamber shown indicatively. Proposed Drain C to connect to existing drainage run
Boiler Flue to extract through external wall. 1 Where boiler flue passes through timber frame lining to wall 30 minutes fire resistance to be maintained. Intumescent collar to flue to preserve integrity of fire protection to timber dry lining in accordance with approved document B
RWP
MH
Contractor responsible for the design of all drainage. Contractor to check positions of all existing inspection chambers, drainage runs, invert and cover levels. All new drainage runs to external foul water connections to be in accordance with Part H General note: a non-return valve is to be fitted to the drainage system, location to be confirmed on site S.CC
RWP
B
Existing cornice with lead lapped over and toothed into existing brickwork to be retained
Pressurised hot water tank to be part of Contractor's Design; refer to provisional sums Contractor to allow for water connections
Living Room GF.07
2171
Extent of repair and refurbishment / replacement of existing slate roof to be confirmed
Boiler to be part of Contractor's Design; refer to provisional sums
HW GXD.10
Existing brick chimney to be retained
SW 01
SW 02
SW 03
S.CC
Floor Type 1 Existing timber screen to be removed. New glazed sliding doors by Specialist supplier in existing opening, see window schedule. New opening to have level threshold with slot drain
Wall Type 4, existing walls to be dry lined as per finishes schedule
Detail 02 Dwg 1391_C.305
Drain C
Existing painted stone cills to be retained
J.06 Beam to Structural Engineer's spec
Existing masonry to be retained and repaired where required
New opening to be formed in existing wall in accordance with Structural Engineers design and spec. No works to be undertaken without the express consent of the Structural Engineer. Walls to be dry lined as per finishes schedule
Beam to Structural Engineer's spec Beam to Structural Engineer's spec
Detail 06 Dwg 1391_C.304
GW 06
1151
Lintel to Structural Engineer's spec
New low level opening to be formed in existing wall, see elevations and window schedule for information. No works to be undertaken without the express consent of the Structural Engineer. New low level window in opening
Existing RWP to be retained Existing brickwork FW 01
Wall Type 4, existing walls to be dry lined Beam to Structural Engineer's spec
FW 03
FW 02
Existing floor to be retained. Lift and record existing stone flags, install DPM and re-lay in original position.
Dining Area GF.06
Existing wall light to be retained
Existing painted stone cills to be retained
Existing walls to be cut back to widen existing opening
FISHER ROW
J.05
Contractor to form niche in existing wall in accordance with Structural Engineers instructions. Existing joinery to be salvaged and refitted in this location as per Listed Building Consent
Contractor to form niche in existing wall. Existing range to be relocated here
Existing vaulted ceiling retained and repaired in lime plaster
Existing boundary wall
GW 01
Detail 04 Dwg 1391_C.305
Existing partition walls to be cut back to widen existing opening
Existing windows to be retained and refurbished as per window schedule and spec.
GXD.01
Existing fence to be retained
S.FF
549
1150
Existing rear door and fanlight to be retained, repaired and refurbished. Door and fanlight to be used at entrance to Flat 3
GXD.06
GXD.11
+150
+150 Beam to Structural Engineer's spec
Lintel to Structural Engineer's spec
New brickwork built off starter bars 1177
GXD.08
new towel rail
1077
S.AA
Bathroom GF.04
838x1981
2037
new radiator
+310
Intermittent mechanical extract to be min. 15 L/s in accordance with Approved Document F. Ducting route to be confirmed New stone steps in new opening Existing joinery to be retained and refurbished, see joinery schedule
15 L/s
GD.05
J.01
RWP
Existing joinery to be retained and refurbished, see specification Existing fireplace to be retained. Head height of fireplace to be raised to 100mm below ceiling height in accordance with Structural Engineers instructions. New basin and mirror to be fitted in fireplace
J.04 9
8
7
6
5
4
3
2
J.02
1
J.03
Drain A
Drain D
SVP-A
Existing fireplace to be retained. Contractor to ensure protection of fireplace throughout the course of works
Existing fireplace and hearth to be retained. Contractor to ensure protection of fireplace throughout the course of works
existing GD.01
GD.02
Existing skirting, dado rail and cornice to be retained. Contractor to remove skirting and cornice and ensure their safe protection prior to reinstatement Retain and refurbish existing door and fanlight, see door schedule Contractor to carefully remove and salvage existing cornice where present. Contractor to fix 12.5mm plasterboard to existing ceiling, existing lathe and plaster ceiling to be retained subject to architect assessment of its condition upon commencement of the works as per the Listed Building Consent. See drawing 1391_C.307 for new party floor build up. Existing cornice to be reinstated below new ceiling
existing radiator
Wall Type 1, existing timber structure at first floor to be removed and replaced. Proposed timber structure to be constructed on new masonry wall at ground floor
Flat This drawing is Copyright protected and must not1to be reproduced or used without prior written permission
S.BB
RWP
GW 02 Escape Window Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement of the affected works.
Notes:
This drawing is Copyright protected and must not to be reproduced or used without prior written permission
S.EE
1
2
3
4
Riach Architects Limited,
1
FW 11
Company Number: 8867519
65 Banbury Rd, Oxford, OX2 6PE. mail@riacharchitects.com
2
Existing RWP to be retained Assumed boundary line Existing windows to be retained and refurbished as per window schedule and spec.
3
Project
5m
Existing brick wall taken down and replaced with new Wall Type 2 with brick to match existing
RY
Existing stone
NA
1 Fisher Row Drawing title
Ground Floor Plan
MI
I EL
Date
Ground Floor PlanStage 4
Tel:01865 553772
www.riacharchitects.com
Morrells Farming Ltd
Scale
August 2019
5m
N
0
30 L/s
FW 12
PR
Preliminaries
1:50@A2
1
2171
GW 05 2138
1151
Do not scale from thisGXD.10 drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement of the affected works. This drawing is Copyright protected and must not to be reproduced or used without prior written permission
GW 06
Plastic repair to existing stonework as per specification
Notes:
SOUTH (SIDE) ELEVATION
N
N Notes:
0
FW 13
2600
Client GXD.01 Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. +170 All discrepancies must be reported to the Architect for verification prior to commencement of the affected works.
GW 01 Escape Window
600
15 L/s
Retain and refurbish existing doors and frames, see door schedule Existing skirting, dado rail and cornice to be retained. Contractor to remove skirting and cornice and ensure their safe protection prior to reinstatement
fuse box and meter
existing radiator
1320
1582
existing
Retain and refurbish existing door, see door schedule
Contractor to carefully remove and salvage cornice where existing in GF.01 Bedroom and GF.03 Hallway. Contractor to fix 12.5mm plasterboard to existing ceiling, existing lathe and plaster ceiling to be retained subject to an assessment of its condition upon commencement of the works as per the Listed Building Consent. See drawing 1391_C.307 for new party floor build up. Existing cornice to be reinstated below new ceiling
Bedroom 1 GF.01
2357
Hall GF.03
Bedroom 2 GF.02
Polyester powder coated aluminum clad frame to oriel window, see drawing 1391_C.303
Roof Type 1, standing seam zinc roof
820
Contractor to carefully remove existing floor boards and skirting and ensure safe storage during works. 25x25mm battens fixed to existing timber floor joists to fit Rockwool insulation with vapour permeable membrane over. Existing timber floor boards and skirting to be re-laid in original locations
existing radiator
Existing floor to be retained. Lift and record existing stone flags, install DPM and re-lay in original position.
All extract outlets to be be finished in the same colour as aluminium elements
All drawings to be read in conjunction with Structural Engineers drawings and details
1957
Contractor to carefully remove and number existing floor boards and skirting and ensure safe storage during works. 25x25mm battens fixed to existing timber floor joists to fit Rockwool insulation with vapour permeable membrane over. Existing timber floor boards and skirting to be re-laid in original locations
hard wired smoke detector
2394
Existing partition walls and openings to be retained
Communal escape route to have min. 60 minutes fire protection in accordance with Approved Document B
1:50
Refer to provisional sums for sanitaryware
975
Existing wall to be retained
Beam to Structural Engineer's spec
East (Front) Elevation
EAST (FRONT) ELEVATION
1
Internal Partition type 2, timber stud partition to bathroom to be fully filled with Rockwool in accordance with Approved Document E Existing recess to be infilled with brickwork. Existing joinery to be retained, refurbished and relocated. Contractor to make good all finishes
3091
Communal Stairs GF.08
New brickwork built off starter bars
heat and smoke detector
Drain B
1259
S.AA
Intermittent mechanical extract over hob to be min. 30 L/s in accordance with Approved Document F. Ducting route to be confirmed
30 L/s
Existing Beam retained to Structural Engineer's spec
Sealed IC in floor
Lintel to Structural Engineer's spec
GXD.07
Bin storage to be formed below staircase
0
Kitchen GF.05
Detail 04 Dwg 1391_C.305
Flat 1
Detail 12 Dwg 1391_C.302
RWP
GW 270 05
1957
Existing entrance to be relocated. Existing door to be refurbished and re-used in proposed location with demountable flood barrier included
1150
hard wired
1108
Wall Type 2. Existing stair wing to be removed and replaced with facing brickwork at ground floor
314
2138
2754
Beam to Structural Engineer's spec
S.FF New post slot and box in existing boundary wall
Existing stairs to be carefully removed and salvaged for re-use as per Listed Building Consent. Contractor responsible for safe storage of stair timbers. See drawing 1391_C.301 for details. Underside of stairs to be treated with two layers of plasterboard with staggered joints to provide 60 minutes fire protection in accordance with Approved Document B.
GW 02
Retain and refurbish existing painted timber door and fanlight, see door schedule
MH New inspection chamber shown indicatively, location to be confirmed
Existing painted timber porch to be retained
S.DD
Beam to Structural Engineer's spec
S.DD
Existing splayed brick headers over existing windows retained
1:50
0
1
Drawn By
Checked By
TS/SH
TB
Drawing Number
Revision
1391_C.203
-
2
3
4
5m
South (Side) Elevation
All discrepancies must be reported to the Architect for verification prior to commencement of the affected works.
0
1
3
2
5m
4
This drawing is Copyright protected and must not to be reproduced or used without prior written permission
Notes:
Do n
All disc
N
0
1
This
3
2
Notes:
5m
4
S.CC
+700
En Suite FF.15
WC FF.16
Cloaks -
S.BB New elements to match proportions of existing Existing element retained and refurbished
Flat 3
New elements spliced into existing to match
10
11
12
13
14
15
16
17
18
19
+150
Flat 2
S.AA
S.AA
Landing FF.17
Existing posts retained, refurbished and integrated into new staircase
155
S.BB
231
RWP
New section of handrail with detail to match the existing integrated into refurbished existing handrail New spindles with detail to match the existing integrated into new staircase
33.9
S.CC
STAIRS - FIRST FLOOR PLAN
1
1:50
7 Existing masonry wall to be retained
Living Room SF.02
SD.01
Section of existing handrail removed at suitable point in order to shorten overall length on lower flight
S.CC
UPPER FLIGHT DIMS 1:10
New cut string to new staircase to include decorative moulding of proportion and detail to match existing
Existing monkey tail handrail retained and refurbished 245
New Central post of monkey tail handrail to match design of existing
9
8
7
6
5
4
3
2
1
S.BB
New treads and risers to match proportions and details of existing
new radiator
+310
Skirting Profile 'B' 34.1
Detail 02 Dwg 1391_C.302
S.AA
6
1177
S.AA
En Suite FF.04 Existing back door and fanlight to be salvaged, refurbished and re-used at entrance to Flat 3, see door schedule. Existing door and fanlight to be treated to provide min. 60 minutes fire resistance in accordance with Approved Document B, as per specification.
New curtail step to match proportions and detail of existing
S.BB
In board Zinc capping by same supplier as roof (see specification) with conealed gutter behind
Bedroom 2 FF.03
762x1981
STAIRS - ELEMENTS ISOMETRIC VIEW
8
LOWER FLIGHT DIMS 1:10
+150
+150
FD.01
All drawings to be read in conjunctionFlatwith 1 Structural Engineers drawings and details
Cavity closing fire stops in accordance with Approved Document B
S.CC
Wall Type 1, existing lean-to structure to be removed and replaced. Proposed timber structure to be constructed on masonry at ground floor to match existing
Communal Stairs GF.08
19 18 17
STAIRS - GROUND FLOOR PLAN
2
1:50
16
All drawings to be read in conjunction with Structural Engineers drawings and details
Detail 05 Dwg 1391_C.302
15 14 13 12
Living Room SF.02
11 10
Bedroom 2 GF.02
9
Wall Type 2, facing brickwork to match existing
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification Company prior to Riach Architects Limited, commencement of the affected works.
GD.01
65 Banbury Rd, Oxford, OX2 6PE.
Detail 06 Dwg 1391_C.302
Number: 8867519 Tel:01865 553772
This drawing is Copyright protected and must not to be reproduced www.riacharchitects.com mail@riacharchitects.com or used without prior written permission
Client
Notes:
Morrells Farming Ltd
Y R A
FR60
N
Company Number: 8867519
65 Banbury Rd, Oxford, OX2 6PE. mail@riacharchitects.com
Tel:01865 553772
0
Detail 07 Dwg 1391_C.302
www.riacharchitects.com
Morrells Farming Ltd
SECTION BB 1:50
1 Fisher Row Section BB
Scale
August 2019 No. 2 Fisher Row
Stage
RE
P
Flat 2
5m
4
Drawing title
Scale
August 2019
E PR
Stage
Preliminaries
19
17 16 15
Communal Stairs GF.11
Drawn By
TS/SH
18 17
14 13
13 12
12 11
11 10
10 9
9
8
Hall GF.03
Checked By
Revision
1391_C.213
-
Bedroom GF.02
7 6 5 4 3
TB
Drawing Number
Communal Stairs GF.11
16 15
14
1:50@A2 Hall GF.03
Rev
Bedroom FF.02
Communal Stairs GF.11
18
Revisi
En Suite FF.15
19
N
I IL M
Date
En Suite FF.15
65 Ba
2
mail@
1
Client
Morr
Projec
1 Fis
1:50@A2
No. 1 Fisher Row
Preliminaries Existing brick chimney to be retained
Section B-B
Y
I
LIM
Date
Project
1 Fisher Row Section BB
R A N
Project
Drawing title
3
2
Detail 08 Dwg 1391_C.302
Client
1
1
WC FF.16
Hallway FF.03
En Suite FF.15
Landing FF.17
FD.13
Riach Architects Limited,
166
New spindles of design and detail to match existing
Detail 09 Dwg 1391_C.302
Drawn By
TS/SH
Checked By
3
STAIRS - SECTION AA
4
1:50
STAIRS - SECTION BB
5
1:50
Drawin
STAIRS - SECTION CC
Stair
1:50
TB
Drawing Number
Revision
1391_C.213
-
Date
Aug Stage
Prel
Drawin
1391 Extent of repair and refurbishment / replacement of existing slate roof to be confirmed Existing cornice with lead lapped over and toothed into existing brickwork to be retained New RWP and hopper to match existing - see specification for details Existing brick wall
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement of the affected works.
0.7mm Rheinzink standing seam roof.
This drawing is Copyright protected and must not to be reproduced or used without prior written permission
Delta Trela structural underlay.
Notes:
18mm WBP Plywood. 50mm continuous ventilation void. Tyvek breathable membrane.
SW 04
Contractor to form opening in existing wall in accordance with Structural Engineers design and spec. New window and cill to be installed to match existing, see window schedule. Contractor to make good all finishes
175x47 C16 Rafters at 400c/c to SE design and Spec Insect mesh
Roof type 1
Rheinzink gutter profile
Min 3° fall
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement of the affected works.
Polyester powder coated 0.7mm Rheinzink standing seam roof. aluminium capping Delta Trela structural underlay. Open joint oak cladding fixed to 50mm vertical battens within 50mm ventilated cavity 18mm WBP Plywood. Tyvek UV Facade protective membrane
Existing neighbour
This drawing is Copyright protected and must not to be reproduced or used without prior written permission
Notes:
50mm continuous ventilation void.
New steel to Structural Engineers design and spec. Proposed rooflight by Specialist supplier to be installed in strict accordance with manufacturers instructions Detail 02 Dwg 1391_C.302
6 L/s
Roof Type 1, standing seam zinc roof
Tyvek breathable membrane. Polyester powder coated aluminum 175x47 C16 Raftersprofile at 400c/c flashing on timber to SE design and Spec GP 70mm Recticel Eurothane Insect mesh Polyester powder coated aluminum flashing Rheinzink gutter profile
Roof type 1
Min 3° fall
Detail 01 Dwg 1391_C.303 15 L/s
Living Room FF.08
Aluminium trim stop to plasterboard and skim - create 15mm shadow gap between oak board and plastered finish
Proprietary zinc hopper from same supplier as zinc roof - see specification for details
FW 09
Wall Type 1
Detail 01
175x47 C16 Rafters at 400c/c Polyester powder coated aluminum to SE design and Spec flashing on timber profile Insect mesh 70mm Recticel Eurothane GP
Roof type 1
Rheinzinkpowder gutter profile Polyester coated aluminum flashing Detail 03
New windows, see schedule FW 10
This drawing is Copyright protected and must not to be reproduced or used without prior written permission
Notes:
Tyvek breathable membrane.
15mm oak board fixed to 25mm battens - hidden fixings
All extract outlets to be be finished in the same colour as aluminium elements
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement of the affected works.
175x47 C16 Lintels to SE design and specification 0.7mm Rheinzink standing seam roof. Polyester powder coated Delta Trela capping structural underlay. aluminium Velfac window Open cladding fixed to 50mm vertical 18mmjoint WBPoak Plywood. battens within 50mm ventilated cavity 50mm UV continuous void. Tyvek Facade ventilation protective membrane
Detail 03
RL 01
175x47 C16 Lintels to SE design and specification Polyester powder coated aluminium capping
Min 3° fall
Open joint oak cladding fixed to 50mm vertical Velfac window battens within 50mm ventilated cavity Solid Oak Handrail - Profile to be Tyvek UV Facade protective membrane confirmed by Architect
All drawings to be read in conjunction with Structural Aluminium trim stop to plasterboard and skim - create 15mm shadow gap between oak board and plastered Engineers drawings and details
Wall Type 1, existing timber structure at first floor to be removed and replaced. Proposed timber structure to be constructed on new masonry wall at ground floor
finish
Detail 01
15mm oak board fixed to 25mm battens - hidden fixings
Polyester powder coated aluminum flashing on timber profile 70mm Recticel Eurothane GP Polyester powder coated aluminum flashing 25 mm Reveal
Floor Type 2
175x47 C16 Lintels to SE design and specification Velfac window
Detail 03
Velfac PC aluminium cill & clip Velfac window
Aluminium trim stop to plasterboard and skim - create 15mm shadow gap between oak board and plastered finish
Existing boundary wall
15mm oak board fixed to 25mm battens - hidden fixings
Solid Oak Handrail - Profile to be confirmed by Architect
Title
Scale
Polyester powder coated aluminum cladding
Oriel Window FW11 - Section AA
1 : 20
Detail Detail 01
06
70mm Recticel Eurothane GP
Wall Type 2, new brickwork to match existing
25 mm Reveal Velfac window Velfac PC aluminium cill & clip
GXD.08
Existing walls to be dry lined
GXD.07
Riach Architects Limited,
Dining Area GF.06 Contractor to form niche in existing wall. Existing range to be relocated here Contractor to form niche in existing wall in accordance with Structural Engineers instructions. Existing joinery to be salvaged and refitted in this location as per Listed Building Consent
Company Number: 8867519
65 Banbury Rd, Oxford, OX2 6PE. GXD.11
mail@riacharchitects.com
Vertically boarded oak doors to bin storage louvered to allow ventilation to bin store
Tel:01865 553772
www.riacharchitects.com
1
1:50
50mm x 50mm batten
Morrells Farming Ltd
Velfac window
Y AR
Project
Title
Oriel Window FW11 - Section Details
IM EL
Date
Scale
August 2019 Stage
PR
Preliminaries
03
Title
Scale
Detail
Oriel Window FW11 - Section AA
1 : 20
06
Solid Oak Handrail - Profile to be confirmed by Architect
Scale Polyester powder coated 1 : 10 aluminum cladding
50mm x 50mm batten
FW 11
Detail 01
Title
Scale
Detail
Oriel Window FW11 - Typical section
1 : 20
03
Title Oriel Window FW11 - Section AA
70mm Recticel Eurothane GP
Scale
Detail
1 : 20
06
Stainless steel tension wire balustrade guarding fixed through oak boarding - spaced equally @ a maximum of 100mm c/c
Revisions:
Detail 02
Rev
Aluminium trim stop to plasterboard and skim - create 15mm shadow gap between oak board and plastered finish
Checked By
TB
Drawing Number
Revision
1391_C.215
-
50mm x 50mm batten
2 x 12.5mm plasterboard with 3mm skim
Scale
Detail
1 : 10
01
Title
Scale
Detail
Title Window FW11 - Typical section Oriel
1Scale : 20
Detail 03
Oriel Window FW11 - Detail 01
1 : 10
04
FW 11
Aluminium trim stop to plasterboard and skim - create
Ammendment
Title Oriel Window FW11 - Internal Elevation
Scale
Details
Stainless steel tension wire balustrade guarding fixed through oak boarding - spaced equally @ a maximum of 100mm c/c
1 : 20
Detail 07
Revisions:
DuPont Airguard Control Vapour Control Layer Detail 02 50mm Recticel Eurothane GP Stainless steel tension wire balustrade guarding fixed through oak boarding 175mm Rockwool RWA45 15mm oak board fixed to 25mm battens - hidden fixings
Date
Solid Oak Handrail - Profile to be confirmed by Architect
Stainless steel tension wire balustrade guarding fixed through oak boarding
Oriel Window FW11 - Section Details
TS/SH
Detail
15mm oak board fixed to 25mm battens - hidden fixings
1:50@A2Title
Drawn By
Scale 1 : 20
Velfac PC aluminium cill & clip
1 Fisher Row
IN
Title Oriel Window FW11 - Typical section
70mm Recticel Eurothane GP
25 mm Reveal
Section DD
Section D-D
Polyester powder coated aluminum cladding
Client
Drawing title
SECTION DD
Solid Oak Handrail - Profile to be confirmed by Architect
Stainless steel tension wire balustrade guarding fixed through oak boarding 15mm oak board fixed to 25mm battens hidden fixings
Solid Oak Handrail - Profile to be confirmed by Architect
Rev
Date
Ammendment
PROFESSIONAL
THE PROJECT Essex Street is a small row of terrace houses capped by a block of flats, providing a modest contemporary twist on the local Victorian vernacular. During my time on the project, I worked closely with the lead architect through multiple design iterations and planning appeals. I conducted a number of studies in order to rationalise the form and design in relation to the local context of the street and surrounding area.
ESSEX STREET HMO DEVELOPMENT
2019 - 2020
1:500
RIDGE LINES INCLUDING PROPOSAL (AA) BOUNDARY LINE
BOUNDARY LINE
1:500
+ 8600
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement affected works. Do not scale from this drawing. All dimensions are approximate andDo not scale from this drawing. of Allthe dimensions are approximate and should be checked on site prior to construction. should be checked on site prior to construction. Copyright protected and must notfortoverification be reproduced All discrepancies must be reported to the Architect for verification prior All This discrepancies to drawing ismust be reported to the Architect prior to or used without prior written permission commencement of the affected works. commencement of the affected works. This drawing is Copyright protected and must not to be reproduced This drawing is Copyright protected and must not to be reproduced Notes: or used without prior written permission or used without prior written permission
Notes:
+ 9080
+ 8500
+ 8030
+ 7850
Notes:
RIDGE LINES OPPOSITE OF THE PROPOSAL (BB)
1:500
STREET SITE ELEVATION INCLUDING PROPOSAL (AA)
+8810
BOUNDARY LINE
+ 8400
Street Elevation
Front Street Elevation (East) - No front walls 1 Scale 1:100 Front Street Elevation (East) - No Front front walls Street Elevation (East) - No front walls 1 Scale 1:100 1 Scale 1:100
1:500
STREET ELEVATION OPPOSITE OF THE PROPOSAL (BB)
1:500
sed new roof
e tile roof to ch street
er brick course
RIDGE LINES OPPOSITE OF THE PROPOSAL (BB)
Front Street Elevation (East) - Inc. front walls 1:500 2
Brick to match street
East (Front) Elevation
Scale 1:100
2
Front Street Elevation (East) - Inc.Front front Street walls Elevation (East) - Inc. front walls 2 Scale 1:100 Scale 1:100
BOUNDARY LINE
+8810
+ 8400
BOUNDARY LINE
m high fence
+ 7860
Potential brick panel detail
Proposed new roof lights Proposed new roof lights SF SF
Proposed new roof lights Slate tile roof to match street
Slate tile roof to match street
Slate tile roof to match brick streetcourse Soldier
1 FRONT VIEW FROM NORTH
SF Soldier brick course
Soldier brick course
STREET ELEVATION OPPOSITE OF THE PROPOSAL (BB) Riach Architects Limited, FF
FF
Company Number: 8867519
65 Banbury Rd, Oxford, OX2 6PE.
mail@riacharchitects.com
1:500
Brick to match street
Tel:01865 553772
www.riacharchitects.com
Project
2m high fence
GF
3 3
Scale 1:100
Rear Elevation - West
Date
Scale 1:100
2.5
5
7.5
CC/JM
SB
or used without prior written permission
Notes:
Notes:
-
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to Riachcommencement Architects Limited, Company Number: of the affected works.
Bedroom 03 Bedroom 03
This drawing
Notes:
This drawing is Copyright protected and must not to be reproduced or used without prior written permission
must not to be reproduced Drawing NumberThis drawing is Copyright protected andRevision
1695-102Notes:
Do not scale sho All discrepancie
This drawing is Copyright protected and must not to be reproduced or used without prior written permission
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement of the affected works.
West (Rear) Elevation
Drawn ByAll dimensions Checked By Do not scale from this drawing. are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement of the affected works.
Planning
10m
Scale 1:100
Potential brick panel detail
Scale 1:100@A1
Feb 19 Stage
0
Potential brick panel detail
Sections & Elevations
Rear Elevation - West
Do not scale from this drawing. All dimensions are approximate and should be checked on site prior to construction. All discrepancies must be reported to the Architect for verification prior to commencement of the affected works.
Potential brick panel detail
Drawing title
Scale 1:100
5 REAR VI
2m high fence 2m high fence
GF
Former St. Mary and St, John School Hertford Street, Oxford, OX4 3AL
Rear Elevation - West
Visualizations
Brick to match street
Client
Magdalen Road Church GF
3
3 FRONT VIEW FROM SOUTH
Brick to match street
FF
Bedroom 03
8867519
65 Banbury Rd, Oxford, OX2 6PE. Tel:01865 553772 This drawing is Copyright protected and must not to be reproduced Company Number: 8867519 RiachorArchitects Limited, Company Number: 8867519 used without prior written permission mail@riacharchitects.com www.riacharchitects.com
Riach Architects Limited,
65 Banbury Rd, Oxford, OX2 6PE. B
D
A
Bedroom 01
Amenity Space for 3 flats
Garden
B
D
Private amenity
Dining
Bedroom 02
Bedroom 01
Bedroom 02
A
Snug
Dining
Kitchen
Bedroom 01
Kitchen
Snug
Kitchen
Snug
Garden
Garden Dining
Project Magdalen Road Church Former St. Mary and St, John School Project Hertford Street, Oxford, OX4 3AL Former St. Mary and St, John School Former St. Mary and St, John School Drawing title Hertford Street, Oxford, OX4 3AL Hertford Street, Oxford, OX4 3AL Sections & Elevations Project
Drawing title
Private amenity
Amenity Space for 3 flats
Date
Short Section
Utility
Living Room
Lightwell
Home Office Living Room
Utility
Lightwell
Home Office
Lightwell
0Scale 1:100 7.5
2.5
Bathroom
10m
5
Scale 1:100
Utility
WC
WC Lightwell
Up
NO. 56
Up WC
Home office
Lightwell
Down Access to House 1
Lightwell
Lightwell
Lightwell
Up
Down
Down
Home office
Home office
Snug
Snug
Snug
Basement Plan
2 Lightwell
Lightwell
Lightwell
Up
Lightwell
SB
Access to House 4
Access to flat 1
Terrace
Snug
-
Lightwell
Lightwell
Grass
Grass
7 GAP TO NORTHERN NEIGHBOURING DWELLING SHED
Communal garden for 3 flats
NO. 36/38
Communal garden for 3 flats
Revisions:
Access to flats 2 & 3 Up
Terrace
Terrace
Terrace
PRIVATE GARDEN
Terrace
Terrace
Access to House 3
Lightwell
Lightwell
Access to House 4
Private amenity
Access to flats 2 & 3
Access to flat 1
Dining
Date
Amendment
Rev
Date
A
13/09/2018
General issue for comments
A
13/09/2
Terrace
Dining
Dining
Private amenity
ELECTRIC SUB-STA
Dining
Dining
Dining
Dining
ELECTRIC SUB-STA
Dining Bedroom 01
Bedroom 01
1
Basement Plan
Basement Plan
Scale 1:100
2
Revisions:
Rev
Up
Up
Access to House 2
Grass
5 REAR VIEW OF HOUSES
Ground Floor Plan Scale to1:100 Access House 1
BOILER HOUSE Terrace
Grass
Ground Floor Plan
Ground Floor Plan
Scale 1:100
CBF 1.8mh
CBF 1.8mh Kitchen
Kitchen
Bedroom 02
Bedroom 02
A
C
B
D
A
Living
C
Kitchen
Living
Kitchen
Living
Dining
NO. 56
Bike stores (x6)
Living
C
NO. 36/38
Kitchen
Kitchen
Living
Kitchen
Living
Kitchen
Living
Dining
Bike stores (x6)
Living
Living
Living
Up
A
Dn
Bedroom 02
Bedroom Bedroom01 02
1.5 m Ceiling Line 1.5 m Ceiling Line
Kitchen
Bedroom 03
1.5 m Ceiling Line En-suite
1.5 m Ceiling Line
En-suite
En-suite
2806
First Floor Plan
Plans Date
Feb 2019 Stage
3
First Floor Plan 0
N
Scale 1:100
Planning 2.5
5
7.5
10m
Drawing Number
1695-101
CC/JM
7
Access to House 3
Sud's compliant surface Bin store
Grass Bike store
Bike store
Small ornamental tree Existing boundary wall to be removed and replaced with low wall to match neighbouring properties
Access to House 2
Lightwell
Grass
Sud's compliant surface
Asphalt
Small ornamental tree
7
8
9
12
4 3
Bedroom 1
Drawing title mail@riacharchitects.com
Second Floor Plan
Second Floor Plan Scale 1:100
Plans Client
4
Second Floor Plan Scale 1:100
1
House and Flats Site Plan Scale 1:200
0
2.5
5
7.5
10m
Feb 2019
N
Scale 1:100
2.5
5
7.5
10m
Drawn By
CC/JM
Checked By
Drawing Number
Revision
1695-101
-
store
0
1
10 House and 5Flats Site Plan
Scale 1:200 Scale 1:200
15
Access to flat 1
20m
Riach Archite
Company Number: 8867519
compliant
Access to flats 2 & 3
Client
compliant
65 Banbury R
Bin
mail@riachar
Bike surface stores www.riacharchitects.com store
store
trees
(x6)
Client
8 GAP TO SOUTHERN NEIGHBOURING DWELLING Magdale Small ornamental tree
Project
Project
Former St. Mary and St, John School Hertford Street, Oxford, OX4 3AL
Former S Hertford Drawing title
Asphalt
House and Flats Site Plan
House an
Date
Date
Sept 2018
-
SB
surface
surface mail@riacharchitects.com Bike Bin
Scale 1:200@A3
Sept 201
Stage
Drawn By
Planning
GMC/CC SB
Drawing Number
1695-100
Stage
Checked By 0
Revision Scale 1:200
N
0
www.riacharchitects.com
N
Stage
Planning
Sud's
Grass
Drawing title
Scale 1:100@A1
Scale 1:100@A1
Access to House 4
Bin Sud's Sud's 65 Banburycompliant Rd, Oxford, OX2 6PE. 553772 Grass Tel:01865 store
ESSEX STREET
Asphalt
Feb 2019 Former St. Mary and St, John School Drawn OX4 By Stage Checked By Hertford Street, Oxford, 3AL Drawing title Planning CC/JM SB Plans Drawing Number Revision 1695-101 Date
Scale 1:100
Riach Architects Limited, Lightwell
Small Magdalen Road Church ornamental
Magdalen Road Church Date Project
Grass
Small ornamental tree
Former St. Mary and St, John School Riach Architects Limited, Company Number: 8867519 Hertford Street, 3AL553772 65 Banbury Rd, Oxford, Oxford, OX2 6PE. OX4 Tel:01865
1
4
Tel:01865 553772
Lightwell
Bike store
Bin store
Project
2
4 3 2
First Floor Plan
SB -
Lightwell
www.riacharchitects.com
Client
Checked By
Revision
Sud's compliant Bin surface store
Magdalen Road Church
5
6
14 15 16
1.5 m Ceiling Line
N
Scale 1:100
Bike store
Access to House 1
Access to flats 2 & 3
Sud's compliant Bin surface stores (x6)
Company Number: 8867519
ESSEX STREET
Scale 1:100@A1 Drawn By
Bin store
Small ornamental trees
mail@riacharchitects.com
Up
Flat 3
Scale 1:100
Grass
6 REAR VIEW OF FLATS
Small ornamental tree
65 Banbury Rd, Oxford, OX2 6PE.
Bedroom 1
Bedroom 03
1
13
Drawing title
3
Dn
Bedroom 02
Bedroom 02
Former St. Mary and St, John School Hertford Street, Oxford, OX4 3AL
Bedroom 03
Flat 2
Project Bedroom 02
Bedroom 02
Bedroom 03
17
Magdalen Road Church
Bedroom 03
11
Flat 2
Bedroom 2 Flat 3
Client
Bedroom 02
Bin store Potential brick panel detail
Riach Architects Limited, 1.5 m Ceiling Line
Tel:01865 553772
www.riacharchitects.com 12 11
mail@riacharchitects.com
10
Company Number: 8867519
65 Banbury Rd, Oxford, OX2 6PE.
Bedroom 1
Access to flat 1
Sud's compliant surface
3
Up
En-suite
5
Riach Architects Limited, 1.5 m Ceiling Line
Bike store
Bike store
Bin store
Access to House 4
Sud's compliant surface
Potential brick panel detail 8
Bedroom 2
9
Existing boundary wall to be removed and replaced with low wall to match neighbouring properties Bedroom 03
Grass
5
6
12 11
3 2 1
Bedroom 01 02
Bedroom 03
Lightwell
Grass
Asphalt
5
15 16 17
14
5 4 3
Bedroom02 01 Bedroom
Bedroom 03
Lightwell
Kitchen
Small Living ornamental tree
2806
Sud's compliant surface
1
2
Bedroom Bedroom 01 02
13
Bedroom 01 9.5m2
6
Bedroom 03
7
8
9
12
11
10
Kitchen
4
3587
CPD 1m2
En-suite
12
Bedroom 01
1.5 m Ceiling Line
En-suite
11
En-suite
10
Bedroom 01
En-suite
Access to House 3
Sud's compliant surface Bin store
4
Bedroom 01
Grass Bike store
2
Bedroom 01
2806
Bedroom 2
Bike store
Access to House 2
Lightwell Living
Grass
6
En-suite
Lightwell
4 WIDE FRONT VIEW FROM SOUTH 1.5 m Ceiling Line
Living
Access to Community garden
Up
1
1.5 m Ceiling Line
1.5 m Ceiling Line
2 WIDE FRONT VIEW FROM NORTH
Kitchen Bedroom 01 9.5m2
Up
C Access to House 1
Sud's compliant Bin surface store
CPD 1m2
Potential brick panel detail
Kitchen
1.5 m Ceiling Line
Access to Community garden
Up
6
B
D
Living Living
1.5 m Ceiling Line
C
1.5 m Ceiling Line
A
3587
B
D
NO. 36/38
BW 1.7mh CLF 3.3mh
B
Kitchen
BW 1.7mh CLF 3.3mh
Kitchen
NO. 56
D
Rear windows to the Irving building to have obscured film added to the first and second floor windows to a height of 1.7m
Planting Screen
PRIVATE GARDEN
2m high closed board fence
Grass
2m high closed board fence
SHED
Communal stairs
Terrace
BOILER Planting Screen HOUSE
Revision
7 5
6
10
2 1
4
12
3
13 14
11
9
8
Down
Lightwell
Revision
Rear windows to the Irving building to have obscured film added to the first and second floor windows to a height of 1.7m
Screen
Terrace 45 degree line from centre of neighbouring window
Grass
Up
Access to House 3
CC/JM
1695-102
Up
Communal stairs
Living
Home office
Lightwell
Bedroom 02 Living Dining
WC
Up
Access to House 2
Up
Scale 1:100
Grass
Kitchen
Snug
WC
WC
Lightwell Access to flats 2 & 3
Access to flat 1
Grass
Snug
Snug
WC
-
SB By Checked Planting
7
Snug
Kitchen
8
Utility
Down
Kitchen
6
Home office WC
Utility
Down
Kitchen
Drawing Number SBPlanning
1695-102 Revision Drawing Number
Checked By
CC/JM Drawn By
6 REAR VI
4 WIDE FRONT VIEW FROM SOUTH
PRIVATE GARDEN 2 WIDE FRONT VIEW FROM NORTH
Scale 1:100@A1 Scale 1:100@A1 Drawn By
NO. 36/38
3 FRONT VIEW FROM SOUTH Kitchen
Home office
Dining
9
Utility
Down
2m high closed board fence
7
8
Communal stairs
Snug
Down
WC
6 5
9 10
4
2
11
12
3
13
1
14
LivingHome office
NO. 56
WC
CC/JM 10m
7.5
Drawing Number
1695-102
WC
WC
5
WC
Up office Home
WC
11
WC
45 degree line from centre of neighbouring window
Planning
Stage Feb 19 Planning Checked Stage By
Bedroom 01
10
Utility
Kitchen
7.5 board fence 10m closed Drawn By
Feb Date 19
4
Utility
NO. 36/38
Kitchen
12
Utility
Kitchen
3
WC Utility
1
5
Kitchen
Dining
5 2m high Stage
2
Dining
Access to House 4
Dining
2.5
Bedroom 02 Kitchen
1 FRONT VIEW FROM NORTH Lightwell
Dining
0
13
Kitchen
Private amenity
2.5
Scale 1:100 Dining
Scale 1:100 Kitchen
Down
0
Planting Screen
Scale 1:100
Short Section
Sections & Elevations
Date
Scale 1:100@A1
Feb 19
1
4
Scale 1:100
Home Office
Drawing title
Sections & Elevations Bathroom
14
4
Short Section
Utility
Living Room
Bedroom 02
om 03
Garden Dining
C
Garden Dining
Magdalen Road Church Client
Client
Magdalen Road Church
Amenity Space for 3 flats
Bedroom 01
WC
Lightwell
Garden
Dining
4
Snug
Garden
A
B
PRIVATE GARDEN
Garden Dining
Bedroom 01
Kitchen
C
Garden
D
Bathroom
mail@riacharchitects.com
3587
Dining
Dining
Bedroom 02
A
B
D
C
Garden
Tel:01865 553772 65 Banbury Rd, Oxford, OX2 6PE. Tel:01865 553772 Notes: Client www.riacharchitects.com mail@riacharchitects.com www.riacharchitects.com
A
5
10
15
20m
Site Plan
Planning
Drawing Num
1695-100
PROFESSIONAL
THE PROJECT The Patmore Estate, located within the Battersea district, was among several projects where I worked in collaboration with Architects for Social Housing (ASH). The brief aimed to develop the estates infrastructure and landscape as an alternative to demolition and rebuild, in turn resulting in the displacement of the community. This involved working closely with representatives from the estate in order to resolve the conceptual design whilst responding to the needs of the inhabitants.
PATMORE ESTATE FEASIBILITY STUDY
2017 - 2018
PATMORE ESTATE
ROOF EXTENSIONS & INFILL
Patmore Estate master plan axonometric
RO
' RO
BO
LDS
BO
LDS
Ba ni
ni
st
st
er Ho
Communal green spaces Public green spaces 3.2m
Ho or
ga
Communal play spaces Commercial space CO
ill s Ho
e
e us
M
DIY space us e
Ho
e
CW
Private green spaces
AD RO
Ho
us Ho
n
AD RO
M
e
T
us
m
A NN RU CO
El Sub Sta
ft
us
ro hc
s Ho
Ho
e us
e us
e
Ho
M
M
ar
ar
changing rooms offices
sh
sh
e us Ho
e us Ho
( Nur ser y)
coop offices?
view through hall and connection to outdoor play space
Ho Cook h u rt am
(J) u rt Co ok
us Ho
it y
Ce
nt
e
bins/ bike storag recycli e? ng
wl Fo
wl
Fo Ho w le us r e CLOSE BLORE
UN N IO GR OV
OV
MI
E
E
ST RE
rge ry
Fo Ho w le us e
r
PH Su
GR
HU LL
RO
er
Ho
re
EN S
N IO
NS
AD
us w ler Fo
e
un
RE GA Y RD
ry
UN
MI
W OR TH DS
mm
us
RO
Co
W AN
PH
AD
L Schoolk eeper's House
Bil
ain W
RO
2 storey 50 sqm 1 bed flats or 3 bed maisonettes
Ho
e us n Ho gto lin
Ho w rig
ht AD
4
LY
CA
PH rge
e
e
us e Ho an All
us
e
ELE Y RO AD
Fo Su
EN S
us
ell
us e nk
SA
ND EL
AD RO TH
DE
CLOSE
RE GA Y RD
ley
nn
e
Mc Co
us
in
s Ho
k Ho
El Sub Sta
ES
Grif fin Prim ar y School
es
Ho
hic
BLORE
CA
RE ET
Ho
vit
Je
e w ler Fo
W OR DS W AN
ST
Gr
Tre
Ma rtl e y Ho use
e
us Ho
e us n Ho gto lin Bil
e us
E
e
h am
E
CL OS
S
us Ho
ell nn Mc Co
re
Ho
nt
us
er
Ce
Be acon H ouse
GE
e
us e Ho an
e us Ho ht w rig ain W
4
AD RO
L ND EL
CO
it y
Ho
LE IL HV UT
un
on
OR
ND LAET URRE CO ST
mm
pt
El Sub St a
TH
ET
PH
AD
Co
am
BE LM
us
SO
ELE Y RO AD
ND LAET URRE CO ST
Schoolk eeper's House
St George's Chu rch
Cr
Cu dw or th House
RE ST
ET
RO
Bonsor House
e
D
LY
us
OR NF
RE ST
SA
Ho
LI
D
ES
NN RU CO
ley
LE IL HV UT
OR NF
Grif fin Prim ar y School
es
GE OR
ok
nk Je
DE
SO
LI TH
A
RE ET
Ho s Ho
us e
ST
in
All
GE OR
El Sub Sta
ST
ST
Gr
e
AD RO
AD RO
us
a me s Ho
CO
(J)
Ho Cook h u rt am
u rt
E
Co
e
h am
E
CL OS
S GE
Ho
S T'
ick
e us
ith
Be
Ho
ev
an
y
Tr
se M
ET
Be acon H ouse
Ma rtl e y Ho use
e
AC RR
AR
us
El Sub St a
TE
EW
S T'
Ho
E
OR
ST
AR
on
BE LM
le
e us
EW
pt
us
RE ST
Ho
ST
am
s Ho
e
Ho
rt
y
St George's Chu rch Cr
Cu dw or th House
House a me
ll
Ki
Be
ET
Bonsor House
BP
us E OR TM PA
se
Stroudley
e
le
an
us
rt
M
Ho
Ki
House
E
ll
RE ST
A
community centre 18 x 27 x 6 m high hall - basketball? street boxing gym historically street boxing used to take place on the site
entry
BP
E OR TM PA
NN RU CO
WT HO RP E
D
Beatti e Hou se
Stroudley
AC RR
ROA
2.6m
sh
ar
M The Pat mor e Cent re
Dr ur y Hou se
entry
Beatti e Hou se
TE
RPA RCH
us
2.6m
( Nur ser y)
THO
AD AD RO
Ho
ad
RO LY LY
ds
y Br
SSA SA THE ES
e us
oo
D
TH
W
ROA
AD AD RO
Ho
RO LY ALY
ds
Ho
RPA RCH
e us
oo
SS SA THE ES
W
e
TH
us
THO
e
us
sh
ar
M
As
ill
e us
M
Ho
e
Ho
e us
The Pat mor e Cent re
Dr ur y Hou se
AD RO
ha
n
us
DIY space
T RS HU AD W
WT HO RP E
at
ga
Ho
CO
o
e
St
or
m
AD RO
M
e
T
us
ha
Commercial space
ft
Ho
RS HU AD
ck
Ho
at
ro hc
y
W
e us
Private green spaces
Lo
o
e
RS HU AD
ck
e
W
us
E of ol ho
Ho
C
er
Public green spaces
ad
E of C ol 's ho ge Sc or y Ge ar St Pr im
's ge Sc or y Ge ar St Pr im
Ba
Lo
St
As
Br
GO
CW
Parking
CW
CW
GO
Bin Stores
Parking
Communal play spaces
AD RO
Proposed Infill
Proposed Roof Extensions
Garages/ storage
Bin Stores
Communal green spaces
3.2m
A NN RU CO
El Sub Sta
Scale 1:750@A0 2017
Proposed communal Gardens
Entrances
Communal Buildings AD
AD AD RO
Proposed plan
Existing Estate Housing
ME AD
ME AD W
T RS HU AD
ET RE ST
LO CA AS
Entrances
Garages/ storage
Patmore Estate
Scale 1:750@A0 2017
RO AD
AD
N
CRI MS WO RTH
Existing Estate Housing
Communal Buildings
CLO SE
Proposed plan AD
RO AD CRI MS WO RTH
ET RE ST
RO
N
AD RO
AD RO
LO
Scale 1:750@A0 2017
T'S
T'S
CA AS
Patmore Estate
Existing plan AR EW ST
AR EW ST
Patmore Estate
ND
CLO SE
' RO
ND
NS HU LL ST RE
ET
ET
Existing Site Plan
Proposed Site Plan
Roof Extension & Infill Site Plan
Building Typlogy A
PHOTOGRAPHY
PHOTOS The following includes a small selection of my architectural photography. I use framing and composition to capture aspects of architecture that I find unique. The abstract compositions grounded in the familiar challenge me to remain inquisitive throughout my experience of a space. Photography, like sketching, is a means of understanding of the built environment, developing my visual sensitivity and awareness of design.
BILBAO - BASQUE COUNTRY 2018 GUGGENHEIM BILBAO FRANK GEHRY
COPENHAGEN - DENMARK 2017 SKUESPILHUSET LUNDGAARD & TRANBERG ARKITEKTER
LONDON - UK 2017 TROPICAL GREENHOUSE - KEW GARDENS DECIMUS BURTON AND RICHARD TURNER
BORDEAUX - FRANCE 2018 CITÉ DU VIN XTU ARCHITECTS
LONDON - UK 2017 VICTORIA & ALBERT MUSEUM AL_A
BERLIN - GERMANY SUMMER 2017 ROCKET TOWER DE WINDER ARCHITEKTEN
LONDON - UK 2016 NOVA VICTORIA PLP ARCHITECTURE