EXPERIENCE OF BIM ARCHITECTURAL AND INTERIOR DESIGN

01 -

TIME PERIOD: OCT 2021 - PRESENT

-

WORKPLACE: PNP CONSTRUCTIONS

-

ROLE & RESPONSIBILITY: -

PROJECT PLANNING & DESIGN

-

CLIENT LIAISONS

-

BIM (REVIT) COORDINATION INCLUDING (BUT NOT LIMITED) COMPLIANCE MANAGEMENT, DESIGN,

PROJECT MODELLING, CUSTOMISED FAMILIES MODELLING, DRAFTING, TEMPLATE AND DOCUMENTATION MANAGEMENT, QUANTITIES / SCHEDULE MANAGEMENT, REVISION CATALOGUE MANAGEMENT, CONTRACTORS COORDINATION.

-

SAMPLE PROJECTS: 1.1 -

33 CARANDINI STREET, ST HELENS PARK, NSW 2556 - NDIS BATHROOM MODIFICATION

1.2 -

18 TASMAN DRIVE, SHLL COVE, NSW 2059 - NDIS BATHROOM MODIFICATION

1.3 -

9 MALLET AVENUE, BRAHAM LODGE, SA, 5109 - NDIS KITCHEN MODIFICATION


02 EXPERIENCE OF ARCHITECTURAL DESIGN AND PROJECT COORDINATION -

TIME PERIOD: SEP 2020 - APR 2021; OCT 2021 - PRESENT

-

WORKPLACE: SELF-EMPLOYED; PNP CONSTRUCTIONS

-

ROLE & RESPONSIBILITY: -

PROJECT PLANNING & DESIGN

-

CLIENT LIAISONS & CONSULTANTS COORDINATION

-

HERITAGE & CULTURE RESEARCH

-

REGULATION & GUIDELINES PREPARATION

-

DA / PRE-DA, DA to CC / PCA

-

BIM (REVIT) COORDINATION INCLUDING (BUT NOT LIMITED) COMPLIANCE MANAGEMENT, DESIGN, PROJ-

ECT MODELLING, BUILDING PERFORMANCE ANALYSING, CUSTOMISED FAMILIES MODELLING, DRAFTING, TEMPLATE AND DOCUMENTATION MANAGEMENT, QUANTITIES / SCHEDULE MANAGEMENT.

-

SAMPLE PROJECTS: 2.1 -

41-43 WARATAH STREET, HABERFIELD, NSW, 2045 - DUPLEX ADDITION & ALTERATION

2.2 -

5 MONA STREET, ALLAWAH\, NSW, 2218 - APARTMENT BUILDING

2.3 -

85 BADGALLY ROAD, BLAIRMOUNT, NSW, 2559 - HOUSE ADDITION & ALTERATION (INCOMPLETED)

2.4-

11 CAVENDISH STREET, SEMAPHORE, SA, 5019 - HOUSE RE-DEVELOPMENT (INCOMPLETED)


03 EXPERIENCE OF ‘AMATEUR’ ARTIST -

SAMPLE PROJECTS:


1.1

33 CARANDINI STREET, ST. HELENS PARK, NSW 2560 NDIS BATHROOM MODIFICATION

Sheet List

Sheet Number

Sheet Name

A100 A101 A102 A103 A104 A105

Cover Page RENDERINGS SCHEDULE & QUANTITIES Bathroom Floor Plan Bathroom Elevation 1 & 2 Bathroom Elevations 3 & 4

Address: 31 Lasso Rd, Gregory Hills NSW 2557 Phone: 1300 767 462

Client:

Project Name:

REKHA MILLER

Bathroom Modification

Contact: Contact: avstymiss@msn.com

Project Address: 33 Carandini Street, St Helens Park NSW 2560

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components.Any inconsistencies to be reported to Giant immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

True North

Revisions No Date 29.03.22

NO RT H

Description

Ver. App'd

VANITY MIRROR

MP

20.09.21

Bathroom Modification

MP

22.09.21

Toilet Grab Rail & Vanity

MP

22.09.21

Door Swing

MP

22.09.21

Internal Cavity Slider

MP

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Drawing Title Cover Page

Drawing No

A100

Date

30 MAR 2022

Scale

N/A

Drawn By

YUANXIN ZHAO

Issue

A

31/03/2022 10:51:22 AM

(SITE MAP FROM MAPS.SIX.NSW.GOV.AU)

A1


Project Name:

REKHA MILLER

Address: 31 Lasso Rd, Gregory Hills NSW 2557 Phone: 1300 767 462

Contact: avstymiss@msn.com

Project Address:

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components.Any inconsistencies to be reported to Giant immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

True North

Revisions No Date

Description

Ver. App'd

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Drawing Title

Date

RENDERINGS

Drawing No

A101

30 MAR 2022

Scale Drawn By

YUANXIN ZHAO

Issue

A

31/03/2022 10:51:23 AM

Client:

A1


Wall Schedule Keynote WALL A MA-01 WALL B MA-01 WALL D MA-01 WALL E MA-01 WALL C MA-01

Type Mark

Door Schedule

Type Comments

NDIS WALL TILE NDIS WALL TILE NDIS WALL TILE NDIS WALL TILE NDIS WALL TILE

600X300 HORIZONTAL 600X300 HORIZONTAL 600X300 HORIZONTAL 600X300 HORIZONTAL 600X300 HORIZONTAL

MA-02

Type Mark NDIS FLOOR TILE

5.25 m² 5.58 m² 2.80 m² 3.94 m² 2.54 m²

Keynote DO-01

Type Comments P4-5 SANDSTONE 38628SS 300X300

Area 6.33 m²

Description

Manufacturer

JO-01

OL900+STONE TOP+tb872

OSTAR

JO-02

OL900+STONE TOP+tb872 900(W)

OSTAR

Type Comments

Type Comments

URL

CAVITY SLIDERS Thin wall (70mm https://www.cavitysliders. com.au/products/cavity-s stud) standard residential size liders/standard-range cavity pockets, up to 2100 x 920mm

Specialty Equipment Schedule Description

Manufacturer

SE-03

FIXED HANDRAIL

SE-01

Virtu Comfort Grab Rail HORIZONTAL 760x1000mm LH 90° Horizontal Virtu Comfort Grab Rail 870x700mm RH 140° Angled 25MM &32MM Combined Grab Rail & Towel Rail

URL

PRESENT ONLY http://www.ostar.com.au/ind ex.php?route=product/prod uct&product_id=686 PRESENT ONLY http://www.ostar.com.au/ind ex.php?route=product/prod uct&product_id=686

Manufacturer

Cavity Sliders Standard Range

Keynote

Furniture Schedule Keynote

Description

TOTAL 20.11SQM

Floor Schedule Keynote

Area

SE-02

SE-04

Type Comments

URL

Häfele (Thailand) Ltd. GWA Bathrooms & Kitchens

PRESENT ONLY https://www.hafelethailand.co m/ PRESENT ONLY https://www.caroma.com.au/

GWA Bathrooms & Kitchens

PRESENT ONLY https://www.caroma.com.au/

METLAM

PRESENT ONLY https://metlam.com.au/catego ry/straight/MLR32X25X600

Plumbing Fixture Schedule Description

Manufacturer

Type Comments

URL

SA-06

Caroma Care 800 Wall Faced Invisi II Suite

GWA Bathrooms White Only, S Trap Only, http://www.caroma.com.au & Kitchens Sovereign 2000 Bottom Inlet Cistern, Trident Concealed Trap Care Pan, Raised Height Care Buttons

SA-04

WELS 3 Star rated, 9L/min

SA-05 SA-07

TILE INSERT FLOOR WASTE 125MM Toilet Paper Holder

GWA Bathrooms Caroma Essence Shower & Kitchens System PIXI FOUR COLOURS AVAILABLE Milli

SA-03

VIZZINI FRAMELESS FIXED PANEL 1200MM SHOWER SCREEN - 1200MM (L) X 1950MM (H) SHOWER CURTAIN RAIL

RENOVATION KINGDOM BUNNINGS

SA-02 SA-01

ONE WAY ONLY

The Saracom range offers the home owner the practical GWA Bathrooms Caroma Saracom Basin Mixer choice in using one stylish mixer design for the entire & Kitchens home, from the kitchen to the laundry to the bathroom.

Address: 31 Lasso Rd, Gregory Hills NSW 2557 Phone: 1300 767 462

1200MM(L)X1950MM(H)

Client:

Project Name:

REKHA MILLER

Bathroom Modification

Contact: avstymiss@msn.com

Project Address: 33 Carandini Street, St Helens Park NSW 2560

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components.Any inconsistencies to be reported to Giant immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

True North

http://www.caroma.com.au/ https://www.abiinteriors.com.au/product/pixi-floor-waste-tile-insert/ http://www.reece.com.au/bathrooms/products/bathroom/accessories-and-homewares/toilet-rollholders/milli-glance-toilet-roll-holder-black-9503884 https://www.renovationkingdom.com.au/vizzini-frameless-fixed-panel-1200mm-shower-screen-1 200mm-l-x-1950mm-h.html https://www.bunnings.com.au/products/bathroom-plumbing/bathroom/showers/shower-curtain-r ails http://specify.caroma.com.au/products/mixer-taps/saracom/saracom-basin-mixer

Revisions No Date 29.03.22

Description

Ver. App'd

VANITY MIRROR

MP

20.09.21

Bathroom Modification

MP

22.09.21

Toilet Grab Rail & Vanity

MP

22.09.21

Door Swing

MP

22.09.21

Internal Cavity Slider

MP

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Drawing Title SCHEDULE / QUANTITIES

Drawing No

A102

Date

30 MAR 2022

Scale

N/A

Drawn By

YUANXIN ZHAO

Issue

A

31/03/2022 10:51:23 AM

Keynote

A1


2770

GENERAL NOTES:

WALL A 1295

1400 EXISTING WINDOW (APPX MEASUREMENT)

200

SE-01

600

JO-02

JO-01

SA-05

SA-01

900

DRAWING FOR PRESENTATION ONLY

SA-02 OSTAR QL900+STONE TOP+TB872

SEMI-RECESSED MIRRORED CABINET ABOVE HEAD HEIGHT SHOWN AS OVERHEAD LINE

SA-03

2300

1644

WALL E

SA-04

3 4

384

2 1

BILATERAL FIXED RAILS (ENSURE ADEQUATE WALL SUPPORT IS IN PLACE TO ACCOMMODATE GRAB RAIL)

10

AL L

RAK COMPACT BACK-TOWALL TOILET SUITE - GREY SEAT

450

DO-01

W

SA-06

365

SE-03

350

SE-04

WALL B

• At least one WC pan on the entry level, or a level serviced by a lift, shall provide for a minimum clear space of 900mm (width) x1200mm (length immediately forward of the toilet pan) clear of the swing of the door and any other fixtures such as the shower screens or shower screen fixtures or hand wash basin. • 460mm to side wall, - 800+/-10mm front edge of WC pan from back wall, - Minimum 600mm clear of cistern from front edge of WC pan • At least one shower on the entry level, or a level serviced by a lift, shall be provided in a corner of the room with the following provisions: • The shower size shall be a minimum of 1160mm x 1100mm and provided with one of the two circulation spaces for shower as required by AS1428.1. Refer to Figures 8(c) and 8(d). • Shower curtain rail shall be provided around the 1160x1100mm shower space. • Only vertical support grabrail shall be provided to the shower, with provision of height adjustable shower head and hose as per AS1428.1 • Lever style shower tap shall be provided and located in a zone between 900mm to 1100mm above FFL and between 300mm and 800mm from the internal corner. • Shower floor gradient shall be as required by AS1428.1.

SE-02

92

D

1097

800 1897 WALL C

(FROM <SDA DESIGN STANDARDS>

RELOCATED LIGHT SWITCH (COS WITH ELECTRICIAN)

Address: 31 Lasso Rd, Gregory Hills NSW 2557 Phone: 1300 767 462

Client:

Project Name:

REKHA MILLER

Bathroom Modification

Contact: avstymiss@msn.com

Project Address: 33 Carandini Street, St Helens Park NSW 2560

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components.Any inconsistencies to be reported to Giant immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

True North

Bathroom Floor Plan

0

1 : 10

Revisions No Date 29.03.22

NO RT H

Description

Ver. App'd

VANITY MIRROR

MP

20.09.21

Bathroom Modification

MP

22.09.21

Toilet Grab Rail & Vanity

MP

22.09.21

Door Swing

MP

22.09.21

Internal Cavity Slider

MP

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Drawing Title Bathroom Floor Plan

Drawing No

A103

0.1

0.25

0.5m

Date

30 MAR 2022

Scale

1:10

Drawn By

YUANXIN ZHAO

Issue

A

31/03/2022 10:51:24 AM

0

A1


CL 1 2400

CL 1 2400

SA-03

1500

1180

SA-02

DO-01

MA-01

2400

SA-04

BATHROOM ENTRANCE DOOR INTERNAL CAVITY SLIDER 860MM X 2040MM

650

2040

SE-01 SE-04

SE-04 SA-06 TO OPEN SE-03

SA-07

900 430

660

900

SA-06

850

900

1220

MA-01

MA-02

MA-02 FFL 1 0

FFL 1 0

RAK COMPACT BACK-TO-WALL TOILET SUITE GREY SEAT

Bathroom Elevation 2

1

1 : 10

Bathroom Elevation 1 1 : 10

0

Address: 31 Lasso Rd, Gregory Hills NSW 2557 Phone: 1300 767 462

Client:

Project Name:

REKHA MILLER

Bathroom Modification

Contact: avstymiss@msn.com

Project Address: 33 Carandini Street, St Helens Park NSW 2560

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components.Any inconsistencies to be reported to Giant immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

True North

Revisions No Date 29.03.22

Description

Ver. App'd

VANITY MIRROR

MP

20.09.21

Bathroom Modification

MP

22.09.21

Toilet Grab Rail & Vanity

MP

22.09.21

Door Swing

MP

22.09.21

Internal Cavity Slider

MP

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

0.1

0.25

0.5m

Drawing Title Bathroom Elevations 1 & 2

Drawing No

A104

Date

30 MAR 2022

Scale

1:10

Drawn By

YUANXIN ZHAO

Issue

A

31/03/2022 10:51:24 AM

2

A1


OSTAR QL900 +STONE TOP+TB872 PRESENTATIO N ONLY CL 1 2400

CL 1 2400

370

SA-02

JO-02

JO-02

MA-01

484

SA-03

SA-03

900

400 EXISTING WINDOW (APPROX MEASUREMENT OF WINDOW)

2400

2400

401

300

NICHE

SE-02

SA-01 JO-01 SA-07

12

SA-06

900

900

850 430

660

700

900

1200

MA-01

1145

454

JO-01

184 16

SE-03

210

SE-01

SA-01

MA-02

MA-02 FFL 1 0

OSTAR QL900+STONE TOP+TB872 PRESENTATION ONLY

4

Bathroom Elevation 4 1 : 10

RAK COMPACT BACK-TOWALL TOILET SUITE SEAT GREY DRAWING FORPRESENTATION ONLY

OSTAR QL900+STONE TOP+TB872

3

DRAWING FOR PRESENTATION ONLY

Bathroom Elevation 3 1 : 10

0

Address: 31 Lasso Rd, Gregory Hills NSW 2557 Phone: 1300 767 462

Client:

Project Name:

REKHA MILLER

Bathroom Modification

Contact: avstymiss@msn.com

Project Address: 33 Carandini Street, St Helens Park NSW 2560

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components.Any inconsistencies to be reported to Giant immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

True North

Revisions No Date 29.03.22

Description

Ver. App'd

VANITY MIRROR

MP

20.09.21

Bathroom Modification

MP

22.09.21

Toilet Grab Rail & Vanity

MP

22.09.21

Door Swing

MP

22.09.21

Internal Cavity Slider

MP

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

0.1

0.25

0.5m

Drawing Title Bathroom Elevations 3 & 4

Drawing No

A105

Date

30 MAR 2022

Scale

1:10

Drawn By

YUANXIN ZHAO

Issue

A

31/03/2022 10:51:25 AM

FFL 1 0

A1


1.2

18 Tasman Drive Shell Cove NSW 2529 NDIS Bathroom & laundry modification (Living with guardians) Keynote Legend Key Value EL-01 FT-01 FT-02 FT-03 FT-04 FU-01 FU-02

LI-01 LI-02 LI-03 MA-01 MA-02 MA-03 SA-01

Drawing List Sheet No. A101 A102 A103 A104 A105 A106

Sheet Name Detail Floor Plan Elevation 1 Elevation 2 Elevation 3 Elevation 4 Hallway Elevation 1

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

SA-02

Graphic Symbols

SA-04

Plasterboard

SA-05

Tile Existing Structure

SA-06

GPO

SA-07

Overhead Line

SA-09

Hidden Line

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

SA-10

Client Details

Project Details

NDIS NO.: 430353786 CONTACT: Guy Formica - father PHONE: 0400009062 EMAIL: guy@exceltronix.com

PROEJCT NAME: Bathroom modification

OT Details

PROJECT ADD: 18 Tasman Dr, Shell Cove, NSW 2529

NAME: ADD (HEAD OFFICE): CONTACT: PHONE: EMAIL:

Floor Schedule

Keynote Text 50 CFM Fan/Single Speed SLM50 (or similar) Frosted Etched Glass Shower Door By Trinity Frameless Showers Shower Handle Chrome GFR-CH By Highgrove Bathrooms Glass Clip Chrome 10mm GC10-CH By Highgrove Bathrooms Shower Door Hinge Chrome 180 Degree GFH180-CH By Highgrove Bathrooms Bevel Edge Wall Mirror 750mm x 750mm By Fienza Noah Vanity 750mm x 360mm x 880mm Ceramic Thin Narrow Top Hidden Handles from Bathroom Upgrade Kado Lux 3-in-1 Heat Lamp Exhaust White 2053301 By Reece (or existing) Clipsal Pro Series Wiring Devices Schneider Electric Double GPO Clipsal 31BA-WE | 1 Gang Mid Size Switch 10Amp | Standard Series By Sparky Direct 300mmx300mm Matt Antracit 300mmx600mm Aspire White Satin 10mm Tempered Clear Toughened Safety Glass Luna Back to Wall Bath 1400mm LU4WFW By Caroma (or existing) Opal II Wall Faced Toilet Suite 987017W By Caroma (or existing) PIXI Tile Insert Floor Waste 125mm x 125mm By ABI Interiors Custom-Made Tile Insert Floor Waste 1050mm x 100mm Home Collection Grab Rail Shower Set 900mm 98271C3A By Caroma Stylus Blaze Basin Mixer 632201C5A Chrome By Stylus Lever Wall Top Assemblies CL10065.C Chrome By CLARK Tasman II Hand Shower 992546C3A By Caroma (or existing)

Rev.

Description

Date

Issued to

Keynote MA-01 MA-01 MA-04

Type Mark Floor – 300mm x 300mm Matt Antracit Floor – 300mm x 300mm Matt Antracit Hallway Floorboard

Area 6.40 m² 4.92 m² 4.86 m²

Wall Schedule Keynote MA-02 MA-02 MA-02 MA-02 MA-02 MA-02 MA-02 MA-02

Issued by

Type Mark Walls - 300mm x 600mm Aspire White Satin installed vertically Walls - 300mm x 600mm Aspire White Satin installed vertically Walls - 300mm x 600mm Aspire White Satin installed vertically Walls - 300mm x 600mm Aspire White Satin installed vertically Walls - 300mm x 600mm Aspire White Satin installed vertically Walls - 300mm x 600mm Aspire White Satin installed vertically Walls - 300mm x 600mm Aspire White Satin installed vertically Walls - 300mm x 600mm Aspire White Satin installed vertically

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

Cover Page Drawing No

A100

Area 5.81 m² 5.69 m² 5.33 m² 1.92 m² 3.98 m² 1.97 m² 1.75 m² 1.24 m²

22 MAR 2022 N/A

Drawn By

Yuanxin Zhao

Issue

D

A3


90

Window A to remain in existing position on wall A of bathroom

240

290

315 90

Window B to remain in existing position on wall A of bathroom

WINDOW B

4

450

FT-02

750 1 70 150 FT-03

3 Wall E

700

70

2 FT-01

101

Laundry

LI-02 FU-02 SA-07

FT-04

LI-03

4.98 m²

Wall F

Install 'Noah Vanity' in space formed by floor to ceiling nib wall & 50mm THK CFC sheet wall. Back of vanity to abut CFC sheet wall Plumbing for vanity to come in from wall B and enter through side of vanity

SA-04

1400

Floor to ceiling 70mm nib wall to extend from wall D of bathroom

1210

695 SA-02

2370

Screen door to be pivot and hinged on left side upon entry. Maximise clear opening & minimise lip of framing as much as possible

1210 WINDOW A

450

Install new standard toilet on wall D

90

3340

90 315 240

Provide exhaust fan (leading to outside) on wall A of bathroom. Exhaust fan to be positioned in corner A/D

Rail to be centered under windows A & B. Heigth from finished floor to top of rail to be 900mm

SA-09

Bathroom

SA-10

6.36 m² FCL = 2400mm

100

Light switch to be placed to the left of bathroom entry (external to bathroom). Centre oflight switch to be 1200mm above finished floor

Wall G SA-05

Existing flooring

Tile trim chrome SA-01

MA-01

SA-09

Floor to ceiling 24mm thick CFC sheet wall to extend from wall B to meet up with (and be structurally support by) proposed wall F. Length of nib wall to be approx. 750mm (same width as vanity)

Hallway 4.61 m²

Re-install existing hand-held shower head and rail if re-usable on wall C of shower recess. Lowest fixing point to be 1000mm above finished floor surface. HHSH to be positioned approx. 450mm out from corner B/C

A106 1

CB

Linen

1.12 m²

0.67 m²

Light switch to be relocated from left hand side of wall to the right hand side of wall as shown and to be placed at same height

730

Towel rail to be 1600mm from ground

SA-06

450

100mm ledge for client to sit

Bath taps and existing bath hose to be centered over bath

SA-05

90

Re-install existing bath tub (1480mmx720mm) or insert new bath tub depending on condition. Allow an extra 80mm to proposed length dimensions for re-installation of existing bath tub as a newly proposed bath tub are shown in drawings - 1400mm x 722mm

Shower recess to be contained within the wet area seperated from the rest of the bathroom by the proposed floor to ceiling nib walls. Center shelf between flick mixer tap and bath

LI-03

0

Detail Floor Plan

0 0.1 0.2

1 : 25

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client Details

Project Details

NDIS NO.: 430353786 CONTACT: Guy Formica - father PHONE: 0400009062 EMAIL: guy@exceltronix.com

PROEJCT NAME: Bathroom modification

OT Details

PROJECT ADD: 18 Tasman Dr, Shell Cove, NSW 2529

NAME: ADD (HEAD OFFICE): CONTACT: PHONE: EMAIL:

Rev. B1

Description Revision 1

Date 22/03/2022

Issued to Guy FORMICA

Issued by Yuanxin ZHAO

0.5

1.0m

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

22 MAR 2022

Drawing Title

Scale

1:25

Drawn By

Yuanxin Zhao

Issue

D

Detail Floor Plan Drawing No

A101

A3


Re-install existing heat lamp (or new depending on condition of electricals)

Re-install existing hand-held shower head and rail if re-usable on wall C of shower recess. Lowest fixing point to be 1000mm above finished floor surface. HHSH to be positioned approx. 450mm out from corner B/C

Floor to ceiling 70mm nib wall to commence 1050mm out from wall C and extend towards wall A. Length of nib wall to be approx. 500mm (to be in line with outside edge of proposed wall E)

Shower recess to be contained within the wet area seperated from the rest of the bathroom by the proposed floor to ceiling nib walls. Center shelf between flick mixer tap and bath

Screen door to be pivot and hinged on left side upon entry. Maximise clear opening & minimise lip of framing as much as possible

220

CL 1 2400

Install flicker mixer tap on wall C centered between shower head support rail and proposed recess shelf

850

FT-01 FT-03

Bathroom

Hallway

CB

6.36 m²

4.61 m²

1.12 m²

MA-02

FT-03

MA-01

965

1100

MA-02

FT-04

Existing light switch on left hand side wall (side wall of existing cupboard in participant's bedroom) to be relocated to right hand side wall near internal entry to parents' bedroom to enable relocation of linen closet

1550

Wall F MA-02

Wall B

Wall C

MA-03

400

SA-06

1340

FT-04

EXISTING WINDOW A

Window A to remain in existing position on wall A of bathroom

1215

Rail to be centered under windows A & B. Heigth from finished floor to top of rail to be 900mm

660

Wall A

LI-01

FFL 1 0

1

Bathroom Elevation 1

0 0.1 0.2

0.5

1.0m

1 : 20

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client Details

Project Details

NDIS NO.: 430353786 CONTACT: Guy Formica - father PHONE: 0400009062 EMAIL: guy@exceltronix.com

PROEJCT NAME: Bathroom modification

OT Details

PROJECT ADD: 18 Tasman Dr, Shell Cove, NSW 2529

NAME: ADD (HEAD OFFICE): CONTACT: PHONE: EMAIL:

Rev.

Description

Date

Issued to

Issued by

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

Bathroom Elevation 1

Drawing No

A102

22 MAR 2022 1:20

Drawn By

Yuanxin Zhao

Issue

D

A3


Floor to ceiling 70mm nib wall to commence 1050mm out from wall C and extend towards wall A Install 'Noah Vanity' in space formed by floor to ceiling nib wall & 50mm THK CFC sheet wall. Back of vanity to abut CFC sheet wall

Screen door to be pivot and hinged on left side upon entry. Maximise clear opening & minimise lip of framing as much as possible

Floor to ceiling 24mm thick CFC sheet wall to extend from wall B to meet up with (and be structurally support by) proposed wall F. Length of nib wall to be approx. 750mm (same width as vanity)

recessed shower shelf with base height 1350mm Floor to ceiling 70mm nib wall to extend from wall D of bathroom

Plumbing for vanity to come in from wall B and enter through side of vanity

Wall G

Wall E

LI-01

FT-03

750

FT-01 MA-03

FT-04 FU-01

Ensure electrical safety standards are met

4.98 m²

FT-02

Bathroom 6.36 m²

FFL 1 0

2

FT-04

FU-02

1340

620

MA-01

120

DWR

Proposed Frosted Glass

CB

110

DWR

490

1100

MA-02

80 20 260

LI-02

750

400

Niche

260

Laundry

550

MA-02

660

Wall F

CL 1 2400

FT-03

Install flick mixer tap and spout at basin

Vanity unit to be on legs

Bathroom Elevation 2

0 0.1 0.2

0.5

1.0m

1 : 20

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client Details

Project Details

NDIS NO.: 430353786 CONTACT: Guy Formica - father PHONE: 0400009062 EMAIL: guy@exceltronix.com

PROEJCT NAME: Bathroom modification

OT Details

PROJECT ADD: 18 Tasman Dr, Shell Cove, NSW 2529

NAME: ADD (HEAD OFFICE): CONTACT: PHONE: EMAIL:

Rev.

Description

Date

Issued to

Issued by

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

Bathroom Elevation 2 Drawing No

A103

22 MAR 2022 1:20

Drawn By

Yuanxin Zhao

Issue

D

A3


Re-install existing heat lamp (or new depending on condition of electricals) Floor to ceiling 70mm nib wall to extend from wall D of bathroom Install new standard toilet on wall D

Re-install existing bath tub (1480mmx720mm) or insert new bath tub depending on condition. Allow an extra 80mm to proposed length dimensions for re-installation of existing bath tub as a newly proposed bath tub are shown in drawings - 1400mm x 722mm

Provide exhaust fan (leading to outside) on wall A of bathroom. Exhaust fan to be positioned in corner A/D

Shower recess to be contained within the wet area seperated from the rest of the bathroom by the proposed floor to ceiling nib walls. Center shelf between flick mixer tap and bath Wall D

Wall D 220

CL 1 2400

Window A to remain in existing position on wall A of bathroom

EL-01

Bath taps & existing bath hose to be positioned on wall D of bathroom centered over bath

1215

Bathroom 6.36 m² MA-02

MA-02

MA-02

MA-02

1400

Install 1/4 turn lever taps

SA-10

240

965

SA-02

560

815

1340

Wall A

4.61 m²

Wall E

Hallway

Wall C

CB 1.12 m²

420

1600

2400

400

660

LI-01

395

SA-01 MA-01

FFL 1 0

3

Rail to be centered under windows A & B. Heigth from finished floor to top of rail to be 900mm

Bathroom Elevation 3

0 0.1 0.2

0.5

1.0m

1 : 20

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client Details

Project Details

NDIS NO.: 430353786 CONTACT: Guy Formica - father PHONE: 0400009062 EMAIL: guy@exceltronix.com

PROEJCT NAME: Bathroom modification

OT Details

PROJECT ADD: 18 Tasman Dr, Shell Cove, NSW 2529

NAME: ADD (HEAD OFFICE): CONTACT: PHONE: EMAIL:

Rev.

Description

Date

Issued to

Issued by

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

Elevation 3 Drawing No

A104

22 MAR 2022 1:20

Drawn By

Yuanxin Zhao

Issue

D

A3


Re-install existing heat lamp (or new depending on condition of electricals) Window A to remain in existing position on wall A of bathroom

EL-01

Provide exhaust fan (leading to outside) on wall A of bathroom. Exhaust fan to be positioned in corner A/D

215

Exhaust Fan

LI-01

Wall B

Existing window B

Wall D

1585

1215

Existing window A

1220

220

CL 1 2400

Window B to remain in existing position on wall A of bathroom

Install new standard toilet on wall D

Bathroom

420

Wall A

4.98 m² 965

MA-02

965 395

Laundry

6.36 m²

SA-02

MA-01

FFL 1 0

Rail to be centered under windows A & B. Heigth from finished floor to top of rail to be 900mm

Toilet roll holder to be installed on wall A of bathroom. Wholetoilet roll holder to be contained within 150mm-300mm of front of toilet. To be positioned 700-750mm above finished floor

4

0 0.1 0.2

Bathroom Elevation 4

0.5

1.0m

1 : 20

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client Details

Project Details

NDIS NO.: 430353786 CONTACT: Guy Formica - father PHONE: 0400009062 EMAIL: guy@exceltronix.com

PROEJCT NAME: Bathroom modification

OT Details

PROJECT ADD: 18 Tasman Dr, Shell Cove, NSW 2529

NAME: ADD (HEAD OFFICE): CONTACT: PHONE: EMAIL:

Rev.

Description

Date

Issued to

Issued by

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

Elevation 4 Drawing No

A105

22 MAR 2022 1:20

Drawn By

Yuanxin Zhao

Issue

D

B

A3


40 200

CL 1 2400

450

Linen closet to be relocated to opposite side of hallway as shown (second door to participant's bedroom to be closed off to form new linen closet)

40

Cupboard behind wall

450

Depth of linen cupboard to extend from hallway to edge of existing cupboards internal to bedroom

40

Hallway

Door to be hinged on left hand side when facing the linen closet from hallway

450

4.61 m² Linen

200 40

450

40

Configuration: equal distant shelving internal to linen closet (similar configuaration to existing)

FFL 1 0

1

Hallway Elevation 1

0 0.1 0.2

0.5

1.0m

1 : 20

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client Details

Project Details

NDIS NO.: 430353786 CONTACT: Guy Formica - father PHONE: 0400009062 EMAIL: guy@exceltronix.com

PROEJCT NAME: Bathroom modification

OT Details

PROJECT ADD: 18 Tasman Dr, Shell Cove, NSW 2529

NAME: ADD (HEAD OFFICE): CONTACT: PHONE: EMAIL:

Rev.

Description

Date

Issued to

Issued by

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

22 MAR 2022

Drawing Title

Scale

1:20

Drawn By

Yuanxin Zhao

Issue

D

Hallway Elevation 1 Drawing No

A106

A3


1.3

9 Mallet Avenue, Brahma Lodge, SA 5109 NDIS KITCHEN MODIFICATION (SOLO OCCUPANCY) Keynote Legend Key Value AP-01 AP-05 AP-06 JO-01 JO-02 JO-03 JO-04 JO-05 JO-06 JO-07 JO-08 JO-09 JO-10 JO-11 SA-01 SA-02

Sheet List Sheet Number A101 A102 A103 A104 A105 A106 A107 Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

Sheet Name Cover Page Kitchen Detail Plan Kitchen Elevation 1 Kitchen Elevation 2 Kitchen Elevation 3 Kitchen Elevation 4 KITCHEN RENDERING All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client:

Project Name:

John Pearce

NDIS Kitchen Modification

Contact:

Project Address:

0450 866 144

9 Mallet Avenue, Brahma Lodge, SA 5109

Keynote Text MIELE 4 ZONES ELECTRIC COOKTOP FISHER & PAYKEL E402BLXFD4 MIELE BUILT-IN INTEGRATED RANGEHOOD PANTRY 300(W) X 2200(H) X 600 (D) OVEN UNIT 600(W) X 600(D) X 2200(H) ABOVE HEAD CABINET 600(W) X 720(H) X 300(D) ABOVE HEAD CABINET 300(W) X 720(H) X 300(D) INTEGRATED RANGEHOOD CABINET 600(W) X 1000(H) X 300(D) ASSISTIVE TECHNOLOGY AUTO FALL-DOWN CABINET 400(W) X 720(H) X 300(D) 3 SHELVES INSIDE FRIDGE CABINET 700(W) X 600(D) X 2150(H) PULL-OUT BIN UNIT 400(W) X 600(D) X 750(H) DISHWASHER UNIT CABINET 630(W) X 600(D) X 750(H) DRAWER 600(W) X 600(D) X 200(H) DRAWER 300(W) X 600(D) X 200(H) ELYSIAN DOMESTIC PULL-OUT KITCHEN MIXER SEBA SINGLE KITCHE SINK

Rev.

Description

Date

Issued to

Issued by

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

Cover Page Drawing No

A101

Drawn By Issue

23 MAR 2022 N/A Yuanxin Zhao A

A3


ABBREVIATIONS: Adjustable Assitive Technology Benchtop Drawer Check on site Finish ceiling level Finished floor level General power outlet Kickboard Lighting Splashback

WALL A 760

2460

980

EXISTING WINDOW

SA-01

• • • •

BENCHTOP

WATER

300

366

FR / BT

JO-05

AP-01

1 4

JO-04

300

OVEN

JO-07

AP-05

2 3

JO-02

Kitchen 13 m²

PANTRY

JO-03

1880

• •

SA-02

420

580

A kitchen shall be provided with the following minimum fixtures: a fixed cooktop (with a rangehood), an in-built oven, a sink (with tap) and a dishwasher. At least 1000mm clearance shall be provided in front of fixed benches and appliances (being the leading edge of the outermost bench and not from the face of cupboards or the kickplate and excluding handles). Where the appliances are not installed, the recessed area provision for an appliance shall be a minimum of 700mm in depth. Task lighting shall be provided above workspaces. A minimum level of 300lux shall be achieved when tested at maximum intervals of 1500mm, directly over the surface of the benchtops. A wall oven shall be provided with features as noted below: Side hinged door with latch side of door next to accessible benchtop. At least a part of the operable part of oven door handle shall be located between 600mm and 1100mm above the FFL. A benchtop surface of minimum 600mm depth shall be provided right next to the cooktop and wall oven (on the latch side of the oven door). This accessible benchtop shall provide a minimum space of 900mm (width) x 440mm (depth) clear of any fixtures other than what is permitted under knee / toe requirements of AS1428.1 under the benchtop. A cooktop shall be provided with features as noted below: • Either electric or induction • Shall be located at least 300mm from any internal corner or wall, excluding the splashback. Lever or sensor type tapware shall be provided to sink to comply with AS1428.1 and shall be located such that the operable parts of the lever tap and water source is not more than 300mm from the edge of benchtop. At least one double GPO shall be provided within 300mm from the front edge of the benchtop (from the edge within the kitchen area) and max height of 1100mm from FFL. GPO shall be located adjacent to a bench of minimum 600mm depth. All internal corridors and passageways shall provide a minimum clear width of 1000mm when measured from skirting to skirting. The dwelling shall provide all doors to and within all areas normally used by the participants, including all external doorways with a minimum clear opening width of 820mm, when measured in accordance with Figure 5.

300

JO-09

CLEARANCE IN FRONT OF APPLIANCES

JO-08

GENERAL NOTES:

600

JO-06

2140

ADJ AT BT DWR COS FCL FFL GPO KB LI SB

4200

JO-01

FCL = 2400mm

WALL MOVED TO WIDEN UP CORRIDOR AND CARER'S SUPERVISION

(FROM <NDIS Specialist Disability Accommodation Design Standard>)

0

600

3580

BT

CLEARANCE IN FRONT OF APPLIANCES

Kitchen Detailed Plan

0 0.1 0.2

1 : 20

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client:

Project Name:

John Pearce

NDIS Kitchen Modification

Contact:

Project Address:

0450 866 144

9 Mallet Avenue, Brahma Lodge, SA 5109

Rev. A1

Description Revision 1: SCHEMATIC DESIGN FOR QUOTES

Date Issued to 26/03/2022 John PEARCE

Issued by Yuanxin ZHAO

0.5

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

Kitchen Detail Plan Drawing No

A102

Drawn By Issue

1.0m

23 MAR 2022 1:20 Yuanxin Zhao A

A3


ABBREVIATIONS: Adjustable Assitive Technology Benchtop Drawer Check on site Finish ceiling level Finished floor level General power outlet Kickboard Lighting Splashback

ELECTRIC BLINDS

GENERAL NOTES:

• •

TOP CAB

365

RANGEHOOD

C.O.S

1000

JO-10

B JO-09 KB

1735 DW

JO-10

KB DWR

AP-04

JO-10 JO-08

430

203

DWR JO-10

DWR

AP-05

SA-02

AP-01

FR

BT

320

FFL 1 0

F SA-01

80

SB

BIN

AP-06

KB

COS

547

COS

Existing Window

FIXED BENCHTOP

C.O.S

830

13 m²

2460

JO-05

SBLASHBACK

Kitchen

ADJ BENCHTOP

1020

CL 1 2400

660

• •

A kitchen shall be provided with the following minimum fixtures: a fixed cooktop (with a rangehood), an in-built oven, a sink (with tap) and a dishwasher. At least 1000mm clearance shall be provided in front of fixed benches and appliances (being the leading edge of the outermost bench and not from the face of cupboards or the kickplate and excluding handles). Where the appliances are not installed, the recessed area provision for an appliance shall be a minimum of 700mm in depth. Task lighting shall be provided above workspaces. A minimum level of 300lux shall be achieved when tested at maximum intervals of 1500mm, directly over the surface of the benchtops. A wall oven shall be provided with features as noted below: Side hinged door with latch side of door next to accessible benchtop. At least a part of the operable part of oven door handle shall be located between 600mm and 1100mm above the FFL. A benchtop surface of minimum 600mm depth shall be provided right next to the cooktop and wall oven (on the latch side of the oven door). This accessible benchtop shall provide a minimum space of 900mm (width) x 440mm (depth) clear of any fixtures other than what is permitted under knee / toe requirements of AS1428.1 under the benchtop. A cooktop shall be provided with features as noted below: • Either electric or induction • Shall be located at least 300mm from any internal corner or wall, excluding the splashback. Lever or sensor type tapware shall be provided to sink to comply with AS1428.1 and shall be located such that the operable parts of the lever tap and water source is not more than 300mm from the edge of benchtop. At least one double GPO shall be provided within 300mm from the front edge of the benchtop (from the edge within the kitchen area) and max height of 1100mm from FFL. GPO shall be located adjacent to a bench of minimum 600mm depth. All internal corridors and passageways shall provide a minimum clear width of 1000mm when measured from skirting to skirting. The dwelling shall provide all doors to and within all areas normally used by the participants, including all external doorways with a minimum clear opening width of 820mm, when measured in accordance with Figure 5.

720

80

ADJ AT BT DWR COS FCL FFL GPO KB LI SB

(FROM <NDIS Specialist Disability Accommodation Design Standard>)

1

Kitchen Elevation 1

0 0.1 0.2

0.5

1.0m

1 : 20

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client:

Project Name:

John Pearce

NDIS Kitchen Modification

Contact:

Project Address:

0450 866 144

9 Mallet Avenue, Brahma Lodge, SA 5109

Rev.

Description

Date

Issued to

Issued by

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

Kitchen Elevation 1 Drawing No

A103

Drawn By Issue

23 MAR 2022 1:20 Yuanxin Zhao A

A3


ABBREVIATIONS: ADJ AT BT DWR COS FCL FFL GPO KB LI SB

Adjustable Assitive Technology Benchtop Drawer Check on site Finish ceiling level Finished floor level General power outlet Kickboard Lighting Splashback

GENERAL NOTES:

• •

• • • •

300

JO-07

Kitchen 13 m²

FR

AP-05

SB 300

STOVE

DWR

B FFL 1 0

GPO

1000

365

• •

CL 1 2400

A kitchen shall be provided with the following minimum fixtures: a fixed cooktop (with a rangehood), an in-built oven, a sink (with tap) and a dishwasher. At least 1000mm clearance shall be provided in front of fixed benches and appliances (being the leading edge of the outermost bench and not from the face of cupboards or the kickplate and excluding handles). Where the appliances are not installed, the recessed area provision for an appliance shall be a minimum of 700mm in depth. Task lighting shall be provided above workspaces. A minimum level of 300lux shall be achieved when tested at maximum intervals of 1500mm, directly over the surface of the benchtops. A wall oven shall be provided with features as noted below: Side hinged door with latch side of door next to accessible benchtop. At least a part of the operable part of oven door handle shall be located between 600mm and 1100mm above the FFL. A benchtop surface of minimum 600mm depth shall be provided right next to the cooktop and wall oven (on the latch side of the oven door). This accessible benchtop shall provide a minimum space of 900mm (width) x 440mm (depth) clear of any fixtures other than what is permitted under knee / toe requirements of AS1428.1 under the benchtop. A cooktop shall be provided with features as noted below: • Either electric or induction • Shall be located at least 300mm from any internal corner or wall, excluding the splashback. Lever or sensor type tapware shall be provided to sink to comply with AS1428.1 and shall be located such that the operable parts of the lever tap and water source is not more than 300mm from the edge of benchtop. At least one double GPO shall be provided within 300mm from the front edge of the benchtop (from the edge within the kitchen area) and max height of 1100mm from FFL. GPO shall be located adjacent to a bench of minimum 600mm depth. All internal corridors and passageways shall provide a minimum clear width of 1000mm when measured from skirting to skirting. The dwelling shall provide all doors to and within all areas normally used by the participants, including all external doorways with a minimum clear opening width of 820mm, when measured in accordance with Figure 5.

B

87

(FROM <NDIS Specialist Disability Accommodation Design Standard>)

2

Kitchen Elevation 2

0 0.1 0.2

0.5

1.0m

1 : 20

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client:

Project Name:

John Pearce

NDIS Kitchen Modification

Contact:

Project Address:

0450 866 144

9 Mallet Avenue, Brahma Lodge, SA 5109

Rev.

Description

Date

Issued to

Issued by

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

Kitchen Elevation 2 Drawing No

A104

Drawn By Issue

23 MAR 2022 1:20 Yuanxin Zhao A

A3


ABBREVIATIONS: ADJ AT BT DWR COS FCL FFL GPO KB LI SB

Adjustable Assitive Technology Benchtop Drawer Check on site Finish ceiling level Finished floor level General power outlet Kickboard Lighting Splashback

GENERAL NOTES:

• •

• •

• • • •

JO-02 JO-04 JO-01

1770

CL 1 2400

JO-01

Kitchen 13 m²

STOVE

JO-11 550

• •

A kitchen shall be provided with the following minimum fixtures: a fixed cooktop (with a rangehood), an in-built oven, a sink (with tap) and a dishwasher. At least 1000mm clearance shall be provided in front of fixed benches and appliances (being the leading edge of the outermost bench and not from the face of cupboards or the kickplate and excluding handles). Where the appliances are not installed, the recessed area provision for an appliance shall be a minimum of 700mm in depth. Task lighting shall be provided above workspaces. A minimum level of 300lux shall be achieved when tested at maximum intervals of 1500mm, directly over the surface of the benchtops. A wall oven shall be provided with features as noted below: Side hinged door with latch side of door next to accessible benchtop. At least a part of the operable part of oven door handle shall be located between 600mm and 1100mm above the FFL. A benchtop surface of minimum 600mm depth shall be provided right next to the cooktop and wall oven (on the latch side of the oven door). This accessible benchtop shall provide a minimum space of 900mm (width) x 440mm (depth) clear of any fixtures other than what is permitted under knee / toe requirements of AS1428.1 under the benchtop. A cooktop shall be provided with features as noted below: • Either electric or induction • Shall be located at least 300mm from any internal corner or wall, excluding the splashback. Lever or sensor type tapware shall be provided to sink to comply with AS1428.1 and shall be located such that the operable parts of the lever tap and water source is not more than 300mm from the edge of benchtop. At least one double GPO shall be provided within 300mm from the front edge of the benchtop (from the edge within the kitchen area) and max height of 1100mm from FFL. GPO shall be located adjacent to a bench of minimum 600mm depth. All internal corridors and passageways shall provide a minimum clear width of 1000mm when measured from skirting to skirting. The dwelling shall provide all doors to and within all areas normally used by the participants, including all external doorways with a minimum clear opening width of 820mm, when measured in accordance with Figure 5.

DWR FFL 1 0

80

(FROM <NDIS Specialist Disability Accommodation Design Standard>)

3

Kitchen Elevation 3 1 : 20

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

0 0.1 0.2

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client:

Project Name:

John Pearce

NDIS Kitchen Modification

Contact:

Project Address:

0450 866 144

9 Mallet Avenue, Brahma Lodge, SA 5109

Rev.

Description

Date

Issued to

Issued by

0.5

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

Kitchen Elevation 3 Drawing No

A105

Drawn By Issue

1.0m

23 MAR 2022 1:20 Yuanxin Zhao A

A3


ABBREVIATIONS: ADJ AT BT DWR COS FCL FFL GPO KB LI SB

Adjustable Assitive Technology Benchtop Drawer Check on site Finish ceiling level Finished floor level General power outlet Kickboard Lighting Splashback

• •

JO-05

PULL-OUT PANTRY

2320

JO-01

INTEGRATED RANGEHOOD

AP-06

AP-02

SA-01

SB SA-02 JO-10

FFL 1 0

AP-03

DWR

JO-11

KNEE-TOE CLEARANCE

JO-11

ABOVE-HEAD CAB

JO-06 1020

ABOVE-HEAD CABINET

1020

JO-03

SBLASHBACK

AT

CLEARANCE

JO-04

ADJ

660

JO-02

KB

13 m²

80

MW

Kitchen

OV

460

596

CL 1 2400

324

• •

720

A kitchen shall be provided with the following minimum fixtures: a fixed cooktop (with a rangehood), an in-built oven, a sink (with tap) and a dishwasher. At least 1000mm clearance shall be provided in front of fixed benches and appliances (being the leading edge of the outermost bench and not from the face of cupboards or the kickplate and excluding handles). Where the appliances are not installed, the recessed area provision for an appliance shall be a minimum of 700mm in depth. Task lighting shall be provided above workspaces. A minimum level of 300lux shall be achieved when tested at maximum intervals of 1500mm, directly over the surface of the benchtops. A wall oven shall be provided with features as noted below: Side hinged door with latch side of door next to accessible benchtop. At least a part of the operable part of oven door handle shall be located between 600mm and 1100mm above the FFL. A benchtop surface of minimum 600mm depth shall be provided right next to the cooktop and wall oven (on the latch side of the oven door). This accessible benchtop shall provide a minimum space of 900mm (width) x 440mm (depth) clear of any fixtures other than what is permitted under knee / toe requirements of AS1428.1 under the benchtop. A cooktop shall be provided with features as noted below: • Either electric or induction • Shall be located at least 300mm from any internal corner or wall, excluding the splashback. Lever or sensor type tapware shall be provided to sink to comply with AS1428.1 and shall be located such that the operable parts of the lever tap and water source is not more than 300mm from the edge of benchtop. At least one double GPO shall be provided within 300mm from the front edge of the benchtop (from the edge within the kitchen area) and max height of 1100mm from FFL. GPO shall be located adjacent to a bench of minimum 600mm depth. All internal corridors and passageways shall provide a minimum clear width of 1000mm when measured from skirting to skirting. The dwelling shall provide all doors to and within all areas normally used by the participants, including all external doorways with a minimum clear opening width of 820mm, when measured in accordance with Figure 5.

DWR

0

GENERAL NOTES:

KB

(FROM <NDIS Specialist Disability Accommodation Design Standard>)

4

Kitchen Elevation 4

0 0.1 0.2

0.5

1.0m

1 : 20

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client:

Project Name:

John Pearce

NDIS Kitchen Modification

Contact:

Project Address:

0450 866 144

9 Mallet Avenue, Brahma Lodge, SA 5109

Rev.

Description

Date

Issued to

Issued by

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

Kitchen Elevation 4 Drawing No

A106

Drawn By Issue

23 MAR 2022 1:20 Yuanxin Zhao A

A3


(ENSCAPE RENDERING)

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client:

Project Name:

Contact:

Project Address:

Rev.

Description

Date

Issued to

Issued by

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

Drawing Title

Scale

KITCHEN RENDERING Drawing No

A107

Drawn By Issue

23 MAR 2022

Yuanxin Zhao A

A3


2.1- HOUSE ADDITION & ALTERATION PROEJCT TIME: SEP 2020 - FEB 2021 PROJECT LOCATION: 41 - 43 WARATAH ST HABERFIELD PROJECT BRIEF: The owner wanted a big habitable building extension to his California-bunglow styled duplex. First, I got the building archive dated back to 1983 from Ashfield City Council, which proved that the property at the corner lot was a twin of shop-top houses by 17 May 1983. Based on this fact, I converted the primary houses back to shop-top houses, so as to get rid of the requirement about backyard gardens. Second, I convinced the owner to remove the low-efficient lightweight structure in his backyard, such that we got enough space to function as private open space. Third, based on my understanding about the owner and his family, I picked up ‘pavillion-concept’ extension from Chapter E2 Haberfield Heritage Conservation Area. The extension is a twin house as well. It woud be easier for him to share his property with his elder daughter’s family.

LOT INFORMATION: R2 LOW DENSITY RESIDENTIAL + B1 NEIGHBOURHOOD CENTER LOT SIZE 383sqm on R2 + 90sqm on B1 GFA 300sqm FSR 0.63 : 1 (within 0.5 retreatment on R2) HEIGHT OF BUILDING: 6m










2.2

11 CAVENDISH ST, SEMAPHORE, SA 5019 PLANNING & CONCEPT STAGE, MORE UPDATES WILL COME SOON!!

THIS PROJECT IS IN PLANNING AND DESIGN CONCEPT STAGE. IT IS A DETAHCED DEWELLING WITH A DOUBLE ATTACHED GARABE. THE PROPERTY IS A PRIVATE HOME FOR A FAMILTY WITH A HIGHLY-DISABLED WHEELCHEER DEPENDENT DAUGHTER. THE FAMILY HAVE APPLIED FOR NDIS SUPPORT. AS A DESIGNER AND NDIS WORKER, MY GOAL IS TO BRING LIGHT AND COMFORTING TO THESE UNFORTUNATE PEOPLE AND FAMILIES AS MUCH AS I CAN WITH MY SPECIALISATION. THAT'S MY MOTIVE AND THE ONLY THING I CAN DO FOR THEM.

Sheet Number

Sheet List

A101 A102 A103 A104 A105

Client:

Address: 31 Lasso Rd, Gregory Hills NSW 2557 Phone: 1300 767 462

Contact:

Sheet Name

COVER PAGE INTERIOR RENDERINGS LOWER LEVEL FLOOR PLAN UPPER LEVEL FLOOR PLAN SECTIONS

Project Name:

Project Address: 11 CAVENDISH ST SEMAPHORE SA

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components.Any inconsistencies to be reported to Giant immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

True North

Revisions Date 28 MAR 2022

NO RTH

A01 Description

App'd

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Drawing Title COVER PAGE

MP

Drawing No

A101

Date

28 MAR 2022

Scale

1:100

Drawn By

Yuanxin Zhao

Issue

A


Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

Client:

Project Name:

Contact:

Project Address:

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

True North

Revisions A01 Date 30 MAR 2022

Description

App'd MP

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

30 MAR 2022

Drawing Title

Scale

1:100

Drawn By

Yuanxin Zhao

INTERIOR RENDERINGS Drawing No

A102

Issue

A


1 A105

5820

24760

3960 2300

300

589

4670

1675

600

1540

3733

1530

1000

2268

3897 1375

625

1550

200

200

1150

200

560

9400

SHR

ROBE 600X1400

3000

5360

KITCHEN / MEAL 4.0X2.8

2130

2960

SHR 1200X1200

BT

ROBE 600X600

PARTICIPANT'S BED 4500

4500

OOA 2.3X2.7

200

1400

SINK

200

1200 CLEARANCE

UP

1255

DW

SHR

ROBE 600X600

90 2000

910

930

4870

1375

2358

9400

6790

5820

200 6880 7170

23560

1200

LOWER LEVEL 1 1 : 100

Client:

Address: 31 Lasso Rd, Gregory Hills NSW 2557 Phone: 1300 767 462

2787

200

200

BT

EQUIPMENT / THERAPY 2.8X2.8

1150

1840

CARERS 2.4X2.8

WC 1.8X2.6

OPTION B: OVERNIGHT FAMILY MEMBER STAY

1

15640

2190

PORCH

2410

ENTRY

5790

1550

LDY 2.5X2.4

CABINET

BT

LOWER-LEVEL FFL1 - 7.30

1150

1000

CABINET

UP

1260

MID-LEVEL FFL3 - 8.65

1200

BL 7.10

1795

15900

600 1060 710

A105

LIFT LANDING SIDE

2

Contact:

Project Name:

Project Address:

11 CAVENDISH ST SEMAPHORE SA

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components.Any inconsistencies to be reported to Giant immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

True North

Revisions Date 28 MAR 2022

A01

Description

App'd

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Drawing Title UPPER LEVEL FLOOR PLAN

MP Drawing No

NO RTH

A103

Date

28 MAR 2022

Scale

1:100

Drawn By

Yuanxin Zhao

Issue

A


1 A105

24760 5100 200

90 3880

3020

90 2690

200 1530

1530

2040

2000

200

9310

90

BED 3.0x5.0

1560 200

ROBE 600X1400

1400

PARTICIPANT'S BED BY SDA DESIGN STANDARDS

SHR

4960

<SDA DESIGN STANDARDS> p44. FIGURE 10 (i)

ROOF OVER

3410

2310

200

DN

VOID 6.6x2.3

UPPER LEVEL FFL2 -10.00

ENSUITE 2.0X2.0

MOM'S BED 4.6X4.5

BED 3.3X4.3

FAMILY 4.5X4.0

4390

LIFT

WALK-IN ROBE

12940

DN

LIFT LANDING SIDE

2 A105

200

ENSUITE 2.0X2.0

4670

3300 90

2

2120 90

4600 90

200

UPPER LEVEL 1 1 : 100

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

Client:

Project Name:

Contact:

Project Address:

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

True North

Revisions A01 Date 30 MAR 2022

Description

App'd MP

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

30 MAR 2022

Drawing Title

Scale

1:100

Drawn By

Yuanxin Zhao

UPPER LEVEL FLOOR PLAN Drawing No

A104

Issue

A


2 A105

CH 2 12700

UPPER LEVEL 1 10000

1

Section A 1 : 100

LOWER LEVEL 1 7300 1 A105

CH 2 12700 CH 1 11050 UPPER LEVEL 1 10000 MID-LEVEL 8650 LOWER LEVEL 1 7300

2

Section B 1 : 100

Address: Unit 1203, 31 Lasso Rd, Gregory Hills, NSW 2557 Email: projects@pnpgroup.co Phone: 1300 767 462

Client:

Project Name:

Contact:

Project Address:

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components. Any inconsistencies to be reported to PNP immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

True North

Revisions A01 Date 30 MAR 2022

Description

App'd MP

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Date

30 MAR 2022

Drawing Title

Scale

1:100

Drawn By

Yuanxin Zhao

SECTIONS Drawing No

A104

Issue

A


2.3 85 BADGALLY RD BLAIRMOUNT NSW BLAIRMOUNT HERITAGE HOUSE ADDITION PRE-PLANNING STAGE, UPDATES WILL COME SOON !! AS THE ARCHITECTURAL DESIGNER AND PROJECT COORDINATOR, I'M EXPERIENCED IN HERITAGE DESIGN IN SYDNEY. IN THIS PROJECT, I'M DONE WITH ARCHIVE RESERACH OF THIS PROPERTY AND REGULATION PREPARATION. THEN I MADE OPTIONS OF BUILDING ENVELOPS IN ACCORDANCE WITH PLANNING COMPLIANCE AND CLIENT'S EXPECTATION, PRE-ASSESSMENT FROM COMPLIANCE AND FEASIBILITY ASPECT VIEW IS ATTACHED TO EACH OF THEM. NEXT, I INVITED CLIENT TO BE ENGAGED IN DESIGN. I ENCOURAGED CLIENT TO ADAPT HER IDEA OF DREAM HOME TO THE BUILDING ENVELOPES I MADE. SHE'S ENJOYING CHATTING WITH HER FAMILY AND DRAWING OUT ROOMS ON THESE PAPERS NOW. THE OPTION PRESENTED IS ONLY ONE EXAMPLE!

HISTORY OF PROPOERTY: OF LESS QUALITY BUT SIMILAR CHARACTER TO VARROVILLE AND HILLCREST, BUT PERHAPS LATER IN PERIOD. THE HIPPED IRON ROOF AND BULL-NOSED VERANDAH ON CAST IRON COLUMNS WITHA DECORATIVE FREIZE AND BRACKETS SUGGEST 1880'S. THE WOOD-SLABBED STABLES WHICH IS USED AS THE GARAGE AND THE OLD STONE SILO ARE THE LAYERS LEFT BY ROUSE FAMILY. IT IS WELL KEPT WITH BEAUTIFUL GARDEN SURROUNDING THE HOUSE AND LEADING UP THE DRIVEWAY. ONE OF THE LATER VICTORIAN COUNTRY HOMES.

LOT SUMMARY: LOT NO: LOT 102 LAND REGISTRATION: DP 708401 HERITAGE ERA: 1880'S | LATE VICTORIA ERA LOT SIZE: 1.147ha PERIMETER: 912m

LZN: ENVIRONMENT MANAGEMENT HOB: 9M FSR: CADASTRE HER: CADASTRE

RECOMMENDATION: THIS OPTION IS RECOMMENDED. FURTHER HERITAGE IMPACE ASSESSMENTS HAVE TO BE CONDUCTED BY REGISTERED HERITAGE ARCHITECTS.

Address: 31 Lasso Rd, Gregory Hills NSW 2557 Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components.Any inconsistencies to be reported to Giant immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

VERANDAH

Client:

Project Name:

RESHMI KUMAR & VICTOR KUMAR

HOME ADDITION AND SUBDIVISION

Contact:

Project Address:

reshmi@investorwomen.com.au

85 BADGALLY RD BLAIRMOUNT NSW

MODERN REAR ADDITION

True North

Revisions Date 21/02/2022

NOR

TH

A01

Description - PRE-ASSESSMENT OF THE MAXIMUM FLOOR AREA FOR THE NEW-PROPOSED SOUTHERN WING. - DIAGRAMING THE COMPLAINT AREA LAYOUT ON THE PREMISES FOR THE CLIENTS TO ORGANISE THEIR IDEAL HOME.

App'd

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Drawing Title

A100

MP

Drawing No

COVER PAGE

Date

26/02/2022

Scale

1:100

Drawn By

Yuanxin Zhao

Issue

A

A1


ANOTHER SIGNIFICANT STREETFRONTAGE VIEWED FROM BADGALLY RD NO PRIMART CHANGES RECOMENDED -

83

00

00

19623

6505

17555

2085

94

PRIMARY STREETFRONTAGE VIEWED FROM BADGALLY RD NO PRIMARY CHANGES RECOMENDED

EXISTING POOL

2068

CURRENT REAR EXTENSION: 69

FLOOR LAYOUT MAYBE REORGANISED; NON-STRUCTURAL WALLS COULD BE REMOVED AND REORIENTATED BY ENGINEERING ASSESSMENT.

14100

9910

00

PRIMARY ENTRANCE TOWARDS BADGALLY RD

1040

5

6160

° .00 68

3000

RECOMMENDED WING BOUNDARY

11697

SE TB AC K

9264

RE AR

BO UN DA RY

IF THE PROPOSAL IS SUPPORTED, THE SHED WILL BE DEMOLISHED

-

IT PROBABLY HAS TO BE RETAINED, AS 'SITTING' IS ONE OF THE CRITERIA FOR HERITAGE HOUSING IN NSW.

8400 2105

4283

-

4810

HERITAGE HOUSE: THE HIPPED IRON ROOF AND BULL-NOSED VERANDAH ON CAST IRON COLUMNS WITHA DECORATIVE FREIZE AND BRACKETS SUGGEST 1880'S. THE WOOD-SLABBED STABLES WHICH IS USED AS THE GARAGE AND THE OLD STONE SILO ARE THE LAYERS LEFT BY ROUSE FAMILY.

LOT BO UNDARY

5 04

ANY CONVERTIONS ON THE CHARACTERS COULD NOT BE SUPPORTED BY THE COUNCIL.

EXISTING BUILDING LINE 8379

BO UN DA R

Y LEGEND:

10 00 0

LO T

HERITAGE HOUSE RECOMMENDED EXTENSION WING AREA RE-SUBDIVISION AREA

Address: 31 Lasso Rd, Gregory Hills NSW 2557 Phone: 1300 767 462

All works to be in accordance with the Building Code of Australia, Australian standards, statutory regulations and local authority requirements. Do not scale drawings. Use figured dimensions only. Check and verify levels and dimensions on site prior to commencement of any work, the preparation of drawings or the fabrication of components.Any inconsistencies to be reported to Giant immediately. If in doubt please ask PNP Group for clarification. Any variation from these drawings requires written approval from PNP Group. This drawing is copyright and can not be reproduced without written consent.

Client:

Project Name:

RESHMI KUMAR & VICTOR KUMAR

HOME ADDITION AND SUBDIVISION

Contact:

Project Address:

reshmi@investorwomen.com.au

85 BADGALLY RD BLAIRMOUNT NSW

True North

Revisions Date 21/02/2022

NOR

TH

Description - PRE-ASSESSMENT OF THE MAXIMUM FLOOR AREA FOR THE NEW-PROPOSED SOUTHERN WING. - DIAGRAMING THE COMPLAINT AREA LAYOUT ON THE PREMISES FOR THE CLIENTS TO ORGANISE THEIR IDEAL HOME.

App'd

PRESENTATION DRAWINGS NOT FOR CONSTRUCTION

Drawing Title

A101

MP

Drawing No

GROUND FLOOR

Date

26/02/2022

Scale

1:100

Drawn By

Yuanxin Zhao

Issue

A

A1


2.4 APARTMENT BUILDING OCT 2019 5 MONA ST ALLAWAH

The project was designed by the registered architect Tony Leung. As an intern architect with a+ Design Group, I observed all the stages of the project and contributed to the whole DA documentary stage. In this portfolio, I kept Tony’s initial scheme, but did new site analysis, floor layouts, elevations, renderings and tectonic study.

PLANNING REQUIREMENTS:

B4 MIXED USE LOT SIZE 19m*49m GFA 1731sqm FSR 1.86 : 1 HEIGHT OF BUILDING 18.6m



A

B

C

D

E

F

G

A

B

C

36000

D

E

F

G

36000

1

1

1

1

WASTE ROOM

COMMUNAL

ENTRY RAMP

10000

2

LOBBY 2

2

SINGLE ROOM 6.89*3.89

DOUBLE ROOM 6.89*7.89

DOUBLE ROOM 6.89*9.89

TWIN ROOM 6.89*9.89

10000

DOUBLE ROOM 6.89*7.72

MANAGER ROOM

2

CIRC

CIRC

3

3

A

B

C

D

E

F

3

3

G

A

Lower ground (1:200)

A

B

C

D

E

F

G

B

C

D

E

F

G

Upper ground (1:200)

B

C

D

E

F

G

A

36000

36000

1

1

TWIN ROOM 6.89*9.89

1

SELF-CONTAINED STUDIO 8.9*4.4

DOUBLE ROOM 6.89*9.89

2

2

TWIN ROOM 6.5*4.4

3

A Level 1-4 (1:200)

B

C

D

E

F

G

SELF-CONTAINED STUDIO 8.9*4.4

SELF-CONTAINED STUDIO 8.9*4.4

2

CIRC

3

SELF-CONTAINED STUDIO 8.9*4.4

10000

2

DOUBLE ROOM 6.89*7.89

10000

DOUBLE ROOM 6.89*8.0

1

CIRC

TWIN ROOM 6.5*4.4

3

3

A Level 5 (1:200)

B

C

D

E

F

G







Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.