1 minute read

Concertina Acoustic Banner

Control Schematic

Features

Advertisement

• NORD IE3 3 Phase Braked Geared Motor

• Localised NORD Inverter Drive

• Mayr ROBA Stop Stage Safety Brake

• TER Limit Switch - End of Travel & Ultimate

• Absolute Rotary Encoder

• Overheat prevention

• Requires a single phase 13 amp 230V power supply per banner.

• E-Stops compliant with ISO 13850

• Tay Wool Serge is our standard fabric which has tested acoustic reports. Other fabric options and colours are also available upon request for varying aesthetic and acoustic performance.

Installation

• Two Unistrut P1000 channels along the full length of the top of the banner enable simple mounting.

• J&C Joel can install the banners or can provide mechanical and electrical drawings to aid your installation.

Control Features

• Two control options; push button control for upto 10 banners. Or a tablet touchscreen control (HMI)

Control Interface

• 300x300 mm MCC control unit for any number of banners at two options; 0.18kW motor and a 0.37kW motor from NORD. These will have encoders, therefore positioning can be achieved.

• Requires an RJ45 & a 2 core YY 0.75mm cable for control. Cables can be daisy chained from banner to banner or configured in a radial circuit.

• Encoders allow for preset positions across the system using our HMI control

• E-stops can interface with other stage engineering packages using a global e-stop system.

• Can integrate into building management systems (BMS).

This article is from: