Water Specialist 1.5" EE Control Valve Programming and Drawings Manual
Page 2
WS 1.5 EE Manual
Regeneration and Error Screens
Regen Screen Displays the time remaining in the current cycle. Pressing REGEN advances to the next cycle.
Error Screen Alternated ashing Err and error code every 3 seconds. Clear by dissconnecting the power supply at the PC board and reconneting, or press the NEXT and REGEN buttons simutaneously for 3 seconds.
Button Operation and Function Scrolls to the next display. Pressing once and releasing will schedule a regeneration at the preset delayed regeneration time. Pressing again and releasing will cancel the regeneration. Pressing and holding for 3 seconds will initiate an immediate regeneration Pressing while in regeneration will advance to the next cycle. Pressing in the program levels will go backwards to the previous screen
Changes variable being displayed.
Key sequence to lock and unlock program settings.
Holding for 3 seconds intitiates a control reset. The software version is displayed and the piston returns to the home/service position, resynchronizing the valve.
WS 1.5 EE Manual
Page 3
User Displays General Operation
When the system is operating, one of five displays may be shown. Pressing NEXT will alternate between the displays shown below.
User 1 Typical user display. If volume is selected in Configuration Settings Step 3CS, shows volume remaining to regeneration. If volume is not selected in Configuration Settings Step 3CS, this screen will not be shown. If a meter is not used this display will not change.
User 2 Displays number of days to next regeneration.
User 3 Displays flow rate in gallons per minute. If a meter is not used this display will be shown but 0 will be displayed. This screen will not be shown if 7 day or 28 day is selected in Configuration Settings Step 3CS.
User 4 Displays total flow in gallons since last rest. If a meter is not used this display will be shown but 0 will be displayed. This screen will not be shown if 7 day or 28 day is selected in Configuration Settings Step 3CS. PRESS THE DOWN ▼ ARROW FOR 3 SECONDS TO RESET TO 0.
User 5 Shows current time.
Setting Time of Day Push NEXT button until time of day screen is displayed. Press and hold the ▲ or ▼ arrow until the correct hour is displayed. Then press the NEXT button. The minutes will flash. Press the ▲ or ▼ arrow until the correct minute is displayed. Press the NEXT button to return to the Display Screens. If the NEXT button is not pressed Hours or Minutes will flash for five minutes before returning to Display Screens.
Page 4
WS 1.5 EE Manual
Installer Display Settings One of three sets of displays will be shown depending on what was selected in Configuration Settings Step 3CS.
Volume (Gallons) selected in Configuration Settings Step 3CS Step 1I
Step 1I - To enter Installer Display press the NEXT and ▲ buttons simultaneously for 5 seconds and release.
Step 2I
Step 2I - Volumetric capacity in gallons to regeneration. Adjustable from 500 to 250,000 (250.0 and x 1000 indicator on). Press NEXT to go to Step 3I. Press REGEN to exit Installer Display. Step 3I
Step 3I - Adjust day override from 1 - 28 or OFF. Press NEXT to go to Step 4I. Press REGEN to return to previous step. Step 4I
Step 4I - Use ▲ or ▼ buttons to set the regen hour. Press NEXT to go to Step 5I. Press REGEN to return to the previous step. Step 5I
Step 5I - Use ▲ or ▼ buttons to set the regen minutes. Press NEXT to exit Installer Display. Press REGEN to return to previous step.
EXIT TO DISPLAY SCREENS
28 Day or 28/Volume (Gallons) selected in Configuration Settings Step 3CS Step 1I
Step 1I - To enter Installer Display press the NEXT and ▲ buttons simultaneously for five seconds and release.
Step 2I
Step 2I - Adjust days from 1 - 28. Press NEXT to go to Step 3I. Press REGEN to exit Installer Display. Step 3I
Step 3I - Use ▲ or ▼ buttons to set time of the regen hour. Press NEXT to go to Step 4I. Press REGEN to return to previous step. Step 4I
EXIT TO DISPLAY SCREENS
Step 4I - Use ▲ and ▼ buttons to set the regen minutes. Press NEXT to exit Installer Display. Press REGEN to return to previous step.
WS 1.5 EE Manual
Page 5
7 Day or 7/Volume (Gallons) selected in Configuration Settings Step 3CS
Step 1I
Step 2I
Step 1I - To enter Installer Display press the NEXT and ▲ buttons simultaneously for 5 seconds and release.
Step 2I - Use ▲ or ▼ buttons to set the current day of the week. Default = 2 (Monday) 1 = SUNDAY 2 = MONDAY 3 = TUESDAY 4 = WEDNESDAY 5 = THURSDAY 6 = FRIDAY 7 = SATURDAY
Press NEXT to go to Step 3I. Press REGEN to exit Installer Display.
EXIT TO DISPLAY SCREENS
Step 3I
Step 3I - Scroll through days 1 to 7 using the NEXT button. Use the ▲ or ▼ buttons to turn regen on or off for each individual day (regen indicator on means regeneration will happen). After completing the 7th day, press NEXT to go to Step 4I. Press REGEN to go to previous display.
Step 4I
Step 4I - Use the ▲ or ▼ buttons to set the regen hour. Press NEXT to go to Step 5I. Press REGEN to go to previous display.
Step 5I
Step 5I - Use the ▲ or ▼ buttons to set the regen minutes. Press NEXT to exit Installer Display. Press REGEN to return to previous display.
Page 6
WS 1.5 EE Manual
Setting Regeneration Cycle Times Step 1CT
Step 1CT - Press NEXT and ▼ simultaneously for 5
Step 2CT
Step 2CT - Adjust the length of the backwash from 1-20
seconds and release. If screen in Step 2CT does not appear, the lock on the valve is activated. To unlock press ▼, NEXT, REGEN, ▲ in sequence, then press NEXT and ▼ simultaneously for 5 seconds and release.
minutes or OFF using the ▲ or ▼ buttons. Default = 8 Press NEXT to go to Step 3CT. Press REGEN to exit Regeneration Cycle Times.
Step 3CT
Step 3CT - Adjust the length of the regenerant draw from 1-99 minutes or OFF using the ▲ or ▼ buttons. Default = 60. Press NEXT to go to Step 4 CT. Press REGEN to return to previous step.
Step 4CT
Step 4CT - Adjust the length of the second backwash from 1-20 minutes or OFF using the ▲ or ▼ buttons. Default = 8. Press NEXT to go to Step 5 CT. Press REGEN to return to previous step.
Step 5CT
Step 5CT - Adjust the length of rinse from 1-20 minutes or OFF using the ▲ or ▼ buttons. Default = 6. Press NEXT to go to Step 6 CT. Press REGEN to return to previous step.
Step 6CT
Step 6CT - Adjust the length of fill from 0.1-99.9 minutes or OFF. Regenerant refills at a rate of 0.5 gpm, 1.9 lpm. Default = 6.
EXIT TO DISPLAY SCREENS
Press NEXT to exit Regeneration Cycle Times. Press REGEN to return to previous step.
WS 1.5 EE Manual
Page 7
Configuration Settings Step 1CS
Step 1CS – Press ▲ and ▼ buttons simultaneously for 5 seconds and release. If screen in Step 2CS does not appear, the lock on the valve is activated. To unlock press ▼, NEXT, REGEN, ▲ in sequence, then press ▲ and ▼ buttons simultaneously for 5 seconds and release.
Step 2CS – Shows 1.5 for 1.5”. Press NEXT to go to Step 3CS. Press REGEN to exit Configuration Settings.
Step 2CS
Step 3CS – Press the ▲ or ▼ buttons to select one of the following:
Step 3CS
Step 4CS
• If Volume (gallons) is selected the regeneration will occur after the specific volume has been used or on the day override (if selected) whichever comes first. • If 28 is selected the regeneration will occur on the day (1 through 28) selected in Installer Display Settings. The total flow and flow rate user displays and the volume display in Diagnostics will not be shown even if a meter is used. • If 28/Volume (gallons) is selected the regeneration will occur on the day (1 through 28) selected in Installer Display Settings. If a meter is not used the total flow and flow rate user displays and the volume display in Diagnostics will be shown as 0. • If 7 is selected the regeneration will occur on the selected day(s) of the week (see instructions contained in Installer Display Settings). The total flow and flow rate user displays and the volume display in Diagnostics will not be shown even if a meter is used. • If 7/Volume (gallons) is selected the regeneration will occur on the selected day(s) of the week (see instructions contained in Installer Display Settings). If a meter is not used the total flow and flow rate user displays and the volume display in Diagnostics will be shown as 0. Press NEXT to go to Step 4CS. Press REGEN to return to previous step.
Step 4CS – Press the ▲ or ▼ buttons to select to regenerate Step 5CS
EXIT TO DISPLAY SCREENS
immediately on 0 or at delayed time. Immediately on 0 can only be selected if Volume (gallons) was selected in step 3CS and a meter must be installed. Delay is the only option for the other Step 3CS selections. Press NEXT to go to Step 5CS. Press REGEN to return to previous step.
Step 5CS – Allows the use of an outside signal to initiate a regeneration. The outside signal is obtained by connection to the two prong connector labeled DP SWITCH on the circuit board. Two types of regeneration initiation are available: immediate or delayed. If dP and Set annotator are displayed regeneration will occur immediately after receiving a 2 minute input signal. The display at the left shows the example of immediate regeneration. If dP, Regen annotator, Set annotator and Time annotator are displayed regeneration will occur at the next scheduled regeneration time after receiving a 2 minute input signal. Press NEXT to exit Configuration Settings. Press REGEN to return to previous step.
Page 8
WS 1.5 EE Manual
Diagnostics Step 1D
Step 1D - Press ▲ and ▼ buttons simultaneously for 5 seconds and release. Then press ▲ and ▼ buttons simultaneously for 2 seconds and release. If screen in Step 2D does not appear the lock on the valve is activated. To unlock press ▼, NEXT, REGEN, ▲ in sequence, then press ▲ and ▼ buttons simultaneously for 5 seconds and release. Then press ▲ and ▼ buttons simultaneously for 2 seconds and release.
Step 2D
Step 2D - Display shows the number of days since a regeneration last occurred. Press NEXT to go to Step 3D. Press REGEN to exit Diagnostics.
Step 3D
Step 3D - Display shows the volume of water treated in gallons treated since the last regeneration. If 7 or 28 was selected in Step 3CS this display will not appear. If Volume (gallons), 28/Volume (gallons), or 7/Volume (gallons) was selected in Step 3CS and no meter is installed this display will read 0. Press NEXT to go to Step 4D. Press REGEN to return to previous step.
Step 4D
Step 4D - Display shows the days in service since start up. Press NEXT to go to Step 5D. Press REGEN to return to previous step.
Step 5D
EXIT TO DISPLAY SCREENS
Step 5D - Display shows the total number of regeneration cycles since start up. Press NEXT to exit Diagnostics. Press REGEN to return to previous step.
WS 1.5 EE Manual
Page 9
WS1.5EE Front Cover and Drive Assembly Drawing No. 1 2 3 4 5 6 Not Shown
Order No. V3175EE-01 V3107-01 V3106-01 V3408EE V3110 V3109 V3186 V3186-01
Description WS1EE Front Cover Assembly WS1 Motor WS1 Drive Bracket & Spring Clip WS1.5 PC Board EE WS1 Drive Gear 12x36 WS1 Drive Gear Cover WS1 AC ADAPTER 110V-12V WS1 AC ADAPTER CORD ONLY
Quantity 1 1 1 1 3 1 1
1
4
6 5
2 3
Page 10
WS 1.5 EE Manual Drive Cap Assembly, Downflow Piston, Regenerant Piston, Spacer Stack Assembly, Drive Back Plate, Main Body and Meter Drawing No. 1 2 3 4 5 6 7 8
Order No. V3004 V3135 V3407 V3174* V3423 V3430 V3178 V3419 V3418 V3441
9 Not Shown
Description WS1 Drive Cap Asy O-ring 228 WS1.5 Piston Downflow Asy WS1 Regenerant Piston WS1.5 Backplate Dowel WS1.5 Spacer Stack Asy WS1 Drive Back Plate O-ring 347 O-ring 328 for valve bodies with NPT threads O-ring 226 for valve bodies with BSPT threads WS1.5 Flow Straightener (located inside meter housing) WS1.5 Meter Housing WS1.5 Meter Housing BSPT WS2 Meter Clip WS1 Meter Asy WS1 Turbine Asy O-ring 215 WS1.5 Valve Body Downflow WS1.5 Valve Body Downflow BSPT
V3437 V3401-01 V3401BSPT-01 V3223 V3003** V3118-01 V3105 V3400-01 V3400BSPT-01
10 11 12 13 14 15
Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
BSPT threads on inlet and outlet ports on the V3400BSPT-01 and V3401BSPT-01. NPT threads on drain and injector ports on V3400BSPT-01. *V3174 WS1 Regenerant Piston not used for backwash only valves. V3010-15Z Injector Plug and V3195-01 WS1 Refill Port Plug ASY must be used for backwash only valves. **After attaching the meter housing to the valve, break out the tab in the back plate and thread the meter cord through. Order number V3003 includes V3118-01 and V3105. NPT
BSPT
15 7
or
12
6 1
2
13 3
14
4 10
5 11
8
Install upper diffuser (not shown)
9
Notch marks appear on hex if BSPT threads.
WS 1.5 EE Manual
Page 11
Injector Cap, Injector Screen, Injector, Plug, Bolts and O-Ring(s) Drawing No. 1 2 3
4
5 Not Shown Not Shown
Order No. V3422 V3403 V3417 V3010-15A V3010-15B V3010-15C V3010-15D V3010-15E V3010-15F V3010-15G V3010-15H V3010-15Z V3404 V3171 V3416
Description Bolt WS1.5 Injector Cap O-ring 220 WS1.5 Injector Asy A Black WS1.5 Injector Asy B Violet WS1.5 Injector Asy C Red WS1.5 Injector Asy D White WS1.5 Injector Asy E Blue WS1.5 Injector Asy F Yellow WS1.5 Injector Asy G Green WS1.5 Injector Asy H Orange WS1.5 Injector Plug WS1.5 Injector Screen O-ring 013 O-ring 012
Quantity 3 1 1
1
1 * *
*The injector or the injector plug each contain one V3416 o-ring 012 (lower) and one V3171 o-ring 013 (upper). 1
2 3
4 5
Page 12
WS 1.5 EE Manual
Refill Flow Control Assembly and Refill Port Plug Drawing No. 1 2 3 4 5 6 7 8 9
Order No. V3195-01 V3415 H4615 V3428* V3163 H4612 JCPG-8PBLK JCP-P-8 V3182
Not Shown
V3434-01
Description WS1 Refill Port Plug Asy WS1.5 BLFC Adapter Clip Retaining WS1.5 Refill Retainer ASY O-ring 019 Elbow Cap ½” Nut Compression ½” Black Insert Polytube ½” WS1 RFC WS1.5 Refill Asy 5/8 x 3/4 (includes fitting, refill retainer assembly, o-ring, nut and polytube insert for 5/8” brine line connection)
Quantity 1 1 1 1 1 1 1 1 1 Option
*V3428 contains a V3182 WS1 RFC Proper RFC orientation directs refill water flow towards the washer face with rounded edges
Water Flow
12 9 2
3
5 6
4
7
10 1 4
5 5
11
9 10 1 5
8
WS 1.5 EE Manual
Page 13
Drain Line ¾” Drawing No. 1 2 3 4 5
Order No. H4615 V3414 V3158-01 V3163 V3159-01
Description Locking Clip WS1.5 DLFC Adapter WS1 Drain Elbow ¾” Male Asy O-ring 019 WS1 DLFC Retainer Asy
6
V3162-032 V3162-042 V3162-053 V3162-065 V3162-075 V3162-090 V3162-100
WS1 DLFC 3.2 gpm (12.1 lpm) for ¾” WS1 DLFC 4.2 gpm (15.9 lpm) for ¾” WS1 DLFC 5.3 gpm (20.1 lpm) for ¾” WS1 DLFC 6.5 gpm (24.6 lpm) for ¾” WS1 DLFC 7.5 gpm (28.4 lpm) for ¾” WS1 DLFC 9.0 gpm (34.1 lpm) for ¾” WS1 DLFC 10.0 gpm (37.9 lpm) for ¾”
Quantity 1 1 1 1 1
One DLFC must be used if ¾” fitting is used
Valves are shipped without drain line flow control (DLFC) – install DLFC before using. Use a minimum drain line size of ¾”.
Proper DLFC orientation directs water flow towards the washer face with rounded edge.
Water Flow
3
4
5
6 1 2
Page 14
WS 1.5 EE Manual
Drain Line 1” Drawing No. 1 2 3 4* 5* 6* 7* 8* 9*
Order No. H4615 V3414 V3008-02 V3163 V3167 V3151 V3150 V3105 V3166 V3190-090 V3190-100 V3190-110 V3190-130 V3190-150 V3190-170 V3190-200 V3190-250
10
Description Locking Clip WS1.5 DLFC Adapter WS1 Drain Ftg 1” Straight O-ring 019 WS1 Drain Ftg Adapter 1” WS1 Nut 1” QC WS1 Split Ring O-ring 215 WS1 Drain Ftg Body 1” WS1 DLFC 9.0 gpm (34.1 lpm) for 1” WS1 DLFC 10.0 gpm (37.9 lpm) for 1” WS1 DLFC 11.0 gpm (41.6 lpm) for 1” WS1 DLFC 13.0 gpm (49.2 lpm) for 1” WS1 DLFC 15.0 gpm (56.8 lpm) for 1” WS1 DLFC 17.0 gpm (64.4 lpm) for 1” WS1 DLFC 20.0 gpm (75.7 lpm) for 1” WS1 DLFC 25.0 gpm (94.6 lpm) for 1”
* Can be ordered as a set, order number V3008-02 WS1 Drain Ftg 1” Straight Proper DLFC orientation directs water flow towards the washer face with rounded edge Water Flow
3
9
10
8
7
6
5
4 1
2
Quantity 1 1 1 1 1 1 1 1 1
One DLFC must be used if 1” fitting is used
WS 1.5 EE Manual
Page 15
Page 16
Form #V3435EE – 6/17/05
WS 1.5 EE Manual