04 line & load reactors 2016 lr

Page 1

LINE & LOAD REACTORS MTE RL Series Peace of mind included. Reactors provide a cost effective solution to power quality degradation due to the increase in non-linear loads such as those produced by variable speed drives (VSDs). The MTE RL series of line and load reactors are bestin-class power quality units with a long history of proven performance. Rugged and robust, they are unequalled in absorbing power line disturbances that can damage or shut down VSDs and other sensitive equipment. They are built to withstand even the most severe power spikes. They work on both the line side and load side to give you an easy solution that reduces nuisance tripping, reduces harmonic distortion and minimises long lead effects. The RL series reactors are a robust, high performance filtering solution for virtually any 4 or 6-pulse rectifier or power conversion unit. There is no need to de-rate these reactors. They are harmonic compensated and protected to assure optimum performance in the presence of harmonics, and can help you meet IEEE-519. Improved power quality, enhanced productivity and complete peace of mind are easy with RL line/load reactors.

Key Features: � Available for 1A to 1,500A applications � Impedance options 3% and 5% � Most robust, highest continuous service factor � Low watts loss � Ease of installation � Reduces energy costs � Reduces audible noise � Available in multiple cabinet designs IP00, IP20 & NEMA 3R � Performance and durability that is unmatched by the competition � 3 year warranty (industry leading)

28

P:  1300 387 326

E:  info@fuseco.com.au

W: www.fuseco.com.au


LINE & LOAD REACTORS

TCI KDR Series Reliable, advanced power quality. Also known as inductors, chokes and line filters, TCI reactors are used on both the input (line) side and the output (load) side of a VSD. Reactors provide a costeffective solution to reducing harmonic distortion and are available in 3% impedance and 5% impedance options. VSDs are beneficial for a wide range of applications, but contain a power conversion process that creates current and voltage distortion that can cause systemwide problems, including: • Transformer and distribution equipment overheating • Random breaker tripping • Sensitive equipment may fail completely • Poor power factor • Reduced system efficiency The addition of a TCI KDR reactor will reduce harmonic content, which reduces the total RMS current and thereby resulting in the following benefits: • Extend the motor life on the output of VSDs • Dampen overshoot peak voltage • Reduce motor heating • Reduce audible noise • Nuisance tripping is less common • Drive uptime is increased • Power factor is improved

Key Features: � Available for 1A to 1,450A applications � Impedance options 3%, 5% and 1.5% � Available for either the line or load side of a VSD � Ease of installation � Reduces energy costs � Reduces audible noise. � Available in multiple cabinet designs IP00, IP20 & NEMA 3R � Available in 415V & 690V

P:  1300 387 326

E:  info@fuseco.com.au

W: www.fuseco.com.au

29


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.