PROJECT DIRECTORY
7. CONTRACTOR SHALL USE THE EXISTING BUILDING IN A MANNER WHICH WILL NOT DEFACE OR DAMAGE THE EXISTING FACILITIES IN ANY FASHION. ALL DAMAGE BY CONTRACTOR AND THEIR FORCES SHALL BE REPAIRED/REPLACED BY THE CONTRACTOR AT NO COST TO THE BUILDING'S OWNER. PROVIDE PROTECTIVE MATERIAL AS WARRANTED. 8. THE CONTRACTOR SHALL FIELD MEASURE ALL DISTANCES AND CLEARANCES PRIOR TO COMMENCEMENT OF NEW WORK OR ORDERING OF MATERIALS. ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT PRIOR TO PROCEEDING WITH THAT PORTION OF WORK. THE CONTRACTOR SHALL NOT SCALE ANY DRAWINGS WITHIN THE CONSTRUCTION DOCUMENTS. ANY DISCREPANCIES SHALL BE RESOLVED BY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THAT WORK.
818.290.3337 (P)
Jack Haupt 626.218.0081 (P)
Loren Lavi, LEED GA 310.717.3433 (P)
2013 CALIFORNIA MECHANICAL CODE AND THE 2012 UNIFORM MECHANICAL CODE 2013 CALIFORNIA FIRE CODE, TITLE 24, PART 9 C.C.R. BASED ON THE 2012 INTERNATION FIRE CODE
SECTION #
MPE ENGINEER
GENERAL CONTRACTOR
Studio+ Architecture
Mistry Engineering, Inc.
Intertex General Contractors, Inc.
2070 Business Center Drive, #295 Irvine, CA 92612
26410 Brooks Circle Stevenson Ranch, CA 91381
28338 Constellation Road, #900 Valencia, CA 91355
Jason Dontje, NCARB, LEED AP BD+C 949.228.7528 (P)
Jamshed (Jim) N. Mistry, P.E., LEED AP BD+C 661.284.3055 (P)
Dale Donohoe 661.702.2200 (P)
DETAIL CALLOUT
SIM
1
SHEET DRAWN ON
BUILDING SECTION CUT
A101
2013 CALIFORNIA EXISTING BUILDING CODE, TITLE 24, PART 10 C.C.R. BASED ON THE 2012 INTERNATIONAL EXISTING BUILDING CODE
11. WHEN REMOVING FIXTURES OR DEVICES, REMOVE ALL ASSOCIATED WIRE, BOXES, FRAMING, PIPING NECESSARY TO ALLOW THE COMPLETE INSTALLATION OF NEW FINISH.
2013 CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN CODE), TITLE 24, PART 11 C.C.R.
12. EVERY EFFORT HAS BEEN MADE TO ACCURATELY DEPICT EXISTING CONDITIONS. HOWEVER, ALL WORK MUST BE VERIFIED IN THE FIELD PRIOR TO THE ORDERING OF ANY MATERIALS OR ANY WORK HAS BEGUN. ANY CONFLICTS BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED IMMEDIATELY TO THE ARCHITECT FOR VERIFICATION AND/OR CORRECTION.
2013 CALIFORNIA REFERENCED STANDARDS CODE, TITLE 24, PART 12 C.C.R. PARTIAL LIST OF APPLICABLE STANDARDS (NATIONAL FIRE PROTECTION ASSOCIATION CODE):
13. ALL SMOKE AND FIRE RATED WALLS SHALL BE LABELED ABOVE THE CEILING WITH RED, PAINTED STENCILED LETTERING IDENTIFYING THE WALL RATING AND STATING "PROTECT ALL PENETRATIONS." STENCILED LABELING SHALL OCCUR ON BOTH SIDES OF EACH SMOKE AND FIRE RATED WALL AT NOT MORE THAN 20 FEET ON CENTER AND ALL WALL TERMINATION OR CHANGES IN DIRECTION SHALL BE DESIGNATED WITH A VERTICAL LINE.
2013 CALIFORNIA BUILDING CODE (FOR SFM) REFERENCED STANDARDS CHAPTER 35
NFPA 14
STANDPIPE SYSTEMS (CALIFORNIA AMENDED) 2013 ED
14. SHOP DRAWINGS AND / OR SUBMITTALS FOR PRODUCTS, MATERIALS, ASSEMBLIES, AND SYSTEMS SPECIFIED IN THE CONTRACT DOCUMENTS SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ARCHITECT PRIOR TO FABRICATION IN ORDER TO VERIFY GENERAL CONFORMANCE WITH THE CONTRACT DOCUMENTS. SHOP DRAWINGS AND SUBMITTALS MUST BEAR A REVIEW STAMP FROM THE CONTRACTOR PRIOR TO BEING SUBMITTED TO THE ARCHITECT. SHOP DRAWING REVIEW AND APPROVAL SHALL NOT RELIEVE ANY PARTY FROM MAINTAINING COMPLIANCE WITH THE CONTRACT DOCUMENTS.
NFPA 17A
WET CHEMICAL EXTINGUISHING SYSTEMS 2013 ED
NFPA 20
STATIONARY PIPES 2013 ED
NFPA 24
PRIVATE FIRE SERVICE MAINS (CALIFORNIA AMENDED) 2013 ED
NFPA 72
NATIONAL FIRE ALARM CODE (CALIFORNIA AMENDED) 2013 ED (NOTE: SEE UL STANDARD 1971 FOR "VISUAL DEVICES")
NFPA 13 2013 ED
NFPA 80
0
KEYNOTE NUMBER (SEE LEGEND ON SHEET)
00
DEMOLITION KEYNOTE
KEYNOTE NUMBER (SEE LEGEND ON SHEET)
? 00
NEW CONSTRUCTION KEYNOTE
1
SHEET DRAWN ON
A101
1
SECTION # SHEET DRAWN ON
SIM
SIM
WALL SECTION CUT
DETAIL SECTION CUT
A101
116-1
DOOR NUMBER
SHEET WHERE ELEVATION IS DRAWN
FINISH DESIGNATION
P-1
FINISH TAG
SHEET WHERE ELEVATION IS DRAWN
A
ELEVATION CALLOUT
A0.00
1i 8' - 6"
LOCATION ON SHEET
NFPA 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEMS 2012 ED
A1
A4
A0.00
A2
NAME ELEV. 0'-0"
INTERIOR ELEVATION CALLOUT
A3
FEC
APPLICABLE REQUIREMENTS OF SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT
FE
WALL MOUNTED FIRE EXTINGUISHER
5. AREA IMMEDIATELY SURROUNDING ALL AREAS OF WORK SHALL BE PROTECTED FROM DANGER OF MATERIALS BEING DROPPED OR DISLODGED.
10. MAINTAIN FIRE PROTECTION AND FIRE ALARM SYSTEMS AT ALL TIMES WITHIN EXISTING FACILITIES. 11. REVIEW ALL EXISTING CONDITIONS, DRAWINGS AND OTHER DOCUMENTS FOR PROPER COORDINATION BETWEEN NEW AND EXISTING CONSTRUCTION. 12. ACTIVE UTILITIES WHOSE LOCATIONS ARE UNKNOWN TO OWNER ARE SUSPECTED TO EXIST. CONTRACTOR SHALL BE CAUTION OF THEIR EXISTENCE. IF THEY ARE ENCOUNTERED, IMMEDIATELY REPORT TO OWNER FOR DIRECTION.
APPLICABLE CODES
SYMBOL LEGEND
19. PROVIDE TEMPORARY DUST, SIGHT, AND SOUND BARRIERS WHEREVER NECESSARY TO LIMIT THE AMOUNT OF NOISE, DUST AND VISUAL POLLUTION WITHIN AND AROUND THE FACILITY, TO MAINTAIN OCCUPANCY AND USE OF OCCUPIED AREAS IN THE EXISTING BUILDING 24 HOURS PER DAY. THE EXACT LOCATION AND QUANTITY OF TEMPORARY BARRIERS IS TO BE DETERMINED BY CONSTRUCTION SCHEDULE AND WORK SEQUENCE. INTERIOR PARTITIONS ARE DEFINED FOR THESE PURPOSES AS FULL HEIGHT 3-5/8" METAL STUD WITH GWB FINISH, PAINTED (COLOR AS SELECTED BY OWNER), SOUND INSULATED WITH FULL HEIGHT 2" (UNFACED) SOUND ATTENUATION BLANKETS, AND SEALED TOP, BOTTOM, AND ENDS TO PREVENT THE PASSAGE OF DUST AND NOISE.
SITE PLAN LEGEND (E) ITEM SCOPE OF WORK AREA (2ND FLOOR) PROPERTY LINE
PARKING LOT
PARKING NOTE: PARKING FOR THIS USE IS APPROVED UNDER PARKING ADJUSTMENT NO. 13-001, MASTER CASE NO. 13-062 ON JUNE 27, 2013.
13. LIMIT USE AND OPERATION AT SITE TO "LIMITS OF CONSTRUCTION," INDICATED AND REQUIRED TO PERFORM WORK. PORTIONS OF SITE BEYOND AREA OF REQUIRED WORK SHALL NOT BE DISTURBED WITHOUT WRITTEN APPROVAL OF OWNER.
P2.2A P2.2B
14. LIMIT USE AND OPERATION WITHIN EXISTING FACILITIES TO AREAS INDICATED FOR CONSTRUCTION WORK AND AS REQUIRED TO PERFORM WORK. OTHER AREAS WITHIN FACILITY SHALL NOT BE DISTURBED OR DISRUPTED. PARKING LOT
15. DAMAGES TO EXISTING STRUCTURE, UTILITIES AND OTHER ITEMS WHICH ARE CAUSED BY CONTRACTOR'S OPERATIONS SHALL BE REPAIRED OR REPLACED TO THEIR ORIGINAL CONDITION.
P2.3 P2.4A P2.4B P2.5A P2.5B P2.6A P2.6B P3.00 E0.1
5 1 A0.1
16. MAINTAIN AND KEEP CLEAR ALL REQUIRED FIRE EXITWAYS THROUGHOUT FACILITY WITHIN AND IN VICINITY OF CONSTRUCTION AREAS. COORDINATE ALTERNATE TEMPORARY EGRESS ROUTES WITH OWNER AND LOCAL FIRE AUTHORITY. 17. THE DEMOLITION DRAWINGS FOR ARCHITECTURAL AND ENGINEERING WORK HAVE BEEN PREPARED USING (AS DESIGNED) DOCUMENTS PROVIDED BY THE OWNER. NEITHER THE OWNER NOR THE ARCHITECT WARRANT THESE TO BE (AS-BUILT) DOCUMENTS AND ACTUAL CONDITIONS MAY VARY.
PARKING LOT
1ST FLOOR SUITE 130: 2,774 SF
1ST FLOOR SUITE 120: 3,374 SF
1ST FLOOR SUITE 110: 2,798 SF
2ND FLOOR SUITE 230: 3,191 SF
2ND FLOOR SUITE 220: 3,141 SF
2ND FLOOR SUITE 210: 2,732 SF
DELETE DETAIL DRINKING FOUNTAIN DIAMETER DIMENSION DOOR LOUVER DOWN DISABLED PERSON ACCESSIBLE DOWNSPOUT DRAWING EACH EXPANSION JOINT ELEVATION ELECTRICAL ELECTRICAL METAL TUBING ENCLOSURE ENGINEER EDGE OF SLAB EQUAL EQUIPMENT EACH WAY EXISTING ECPANSION EXTERIOR FIRE ALARM FLOOR DRAIN FIRE DEPARTMENT CONNECTION FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER W/CABINET FINISH FLOOR FINISH GRADE FIRE HYDRANT FIRE HOSE W/ CABINET FLAT HEAD WOOD SCREW FLOOR FACE OF FACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUD FINISH SURFACE
E0.2 E0.3 E0.4 E0.5 E0.6 E2.0 E2.1 E2.2 E2.3 E3.0 E3.1 E3.2 E3.3 E3.4 E4.0 E5.0 Grand total: 80
MEDICAL OFFICE BUILDING FT FTG GA GALV GB GFRC GYP HB HDWE HM HOR HR HVAC ID IN INT INV JBOX JAN LAV LB(S) MAX MB MDF MFR MH MIN MISC MO MTL (N) NIC NO NR NTS NTS O/ OA OC OD OFCI
FOOT OF FEET FOOTING GAUGE GALVANIZED GYPSUM BOARD GLASS FIBER REINFORCED CONCRETE GYPSUM HOSE BIB HARDWARE HOLLOW METAL HORIZONTAL HOUR HEATING VENTILATION AIR INSIDE DIAMETER INCH OR INCHES INTERIOR INVERT JUNCTION BOX JANITOR CLOSET LAVATORY POUND(S) MAXIMUM MACHINE BOLT MEDIUM DENSITY FIBERBOARD MANUFACTURER MANHOLE MINIMUM MISCELLANEOUS MASONRY OPENING METAL NEW NOT IN CONTRACT NUMBER NON RATED NOT TO SCALE NOT TO SCALE OVER OVERALL ON CENTER OUTSIDE DIAMETER OWNER-FURNISHED CONTRACTOR-INSTALLED
OFOI OH OTO PA PE PERP PH PL PLAM PLUMB PLYWD PM POC PR PREP PSF PSI PVC R RD REC REF REQ RM RWL RO SCHED SECT SF SHT SIM SM SMS SOV SPEC SST STD STL STRUCT T&B TEMP TO TOC TOD
OWNER-FURNISHED OWNER-INSTALLED OPPOSITE HAND OUT TO OUT PUBLIC ADDRESS PAD ELEVATION PERPENDICULAR PANIC HARDWARE PLATE PLASTIC LAMINATE PLUMBING PLYWOOD PARTITION MOUNTED POINT OF CONNECTION PAIR PREPARE POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POLYVINYL CHLORIDE RISER, RADIUS ROOF DRAIN RECESSED REFERENCE REQUIRED ROOM RAIN WATER LEADER ROUGH OPENING SCHEDULE SECTION SQUARE FEET SHEET SIMILAR SURFACE MOUNTED SHEET METAL SCREW SHUT OFF VALVE SPECIFICATION STAINLESS STEEL STANDARD STEEL STRUCTURAL TOP AND BOTTOM TEMPORARY TOP OF TOP OF CURB TOP OF DRAIN
TOP TOPL TOR TOS TOW TST TV TYP UC UNO VCT VERT W W/ W/O WD WH WI WIN WP WS WT WWF x YD
TOP OF PARAPET TOP OF PLATE TOP OF RIDGE TOP OF SLAB TOP OF WALL TOP OF STEEL TELEVISION TYPICAL UNERCUT UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL WIDE FLANGE WITH WITHOUT WOOD WATER HEATER WOODWORK INSTITUTE WINDOW WATERPROOF WOOD SCREW WEIGHT WELDED WIRE FABRIC BY YARD
1ST FLOOR SUITE 140: 2,872 SF
1ST FLOOR SUITE 150: 1,813 SF
1ST FLOOR SUITE 160: 4,172 SF
2ND FLOOR SUITE 240: 2,694 SF
2ND FLOOR SUITE 250: 2,951 SF
2ND FLOOR SUITE 260: 3,199 SF
MEDICAL OFFICE TENANT IMPROVEMENT THIS IS NOT AN OSHPD III PROJECT
SCOPE OF WORK:
REMODEL EXISTING TENANT SUITE INCLUDING NEW NON-BEARING WALLS, CASEWORK, DOORS & HARDWARE, CEILINGS, LIGHTING, AND MODIFICATIONS TO MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS.
ACCESSIBILITY SCOPE OF WORK:
EXISTING ACCESSIBILITY ITEMS SERVING AREA OF WORK ARE FULLY COMPLIANT WITH THE 2013 CALIFORNIA BUILDING CODE
CALGREEN SCOPE OF WORK:
REFERENCE SHEET G0.2
UNDER SEPARATE PERMIT:
FIRE ALARM AUTOMATIC FIRE SPRINKLERS DEMOLITION
BIDDING ALTERNATES
12/30/15
ADD ALTERNATE: PROVIDE SOLID SURFACE COUNTERTOPS AND TRANSACTION COUNTERTOPS PER SS-1 OF FINISH SCHEDULE
12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15
PROJECT TYPE:
BUILDING INFO
5
ASSESSOR'S PARCEL #:
2861-009-042
OCCUPANCY TYPE:
(B) AMBULATORY CARE
CONSTRUCTION TYPE:
TYPE V-B
AUTOMATIC SPRINKLERS:
YES
NUMBER OF STORIES:
2 STORIES
BUILDING GROSS AREA:
47,398 SF
2ND FLOOR GROSS AREA:
21,221 SF
SCOPE OF WORK GROSS AREA:
SUITE 240 = 2,691 S.F. SUITE 250 = 2,951 S.F. SUITE 260 = 3,199 S.F. TOTAL = 8,841 S.F.
5
VICINITY MAP
12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15
MAG IC
12/30/15 12/30/15
5
12/30/15 12/30/15
CRE EKS IDE RD.
MO UNT AIN PKW Y.
PROJECT SITE
D. BLV A I C LEN VA
R. ED T ON LM E D
W
Agency Approval:
12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15 12/30/15
01/20/16 01/20/16
Architect/Engineer of Record A RCH S ED I EN A . DO T N N O
NO. C-32176
01/20/16 01/20/16 01/20/16 01/20/16 01/20/16
TE
A
FF FG FH FHC FHWS FL FO FOC FOF FOM FOS FS
P2.1B
12/30/15 12/30/15 12/30/15 12/30/15 12/30/15
CITY OF HOPE NATIONAL MEDICAL CENTER 1500 EAST DUARTE ROAD DUARTE, CA 91010-3000
EN .
R
ABBREVIATIONS
FDN FE FEC
P2.1A
12/30/15 12/30/15
PROJECT TENANT:
ST
CJ CLG CLR CMU CONC CONT CORR CR CTSK CTC d DBL
DS DWG EA EJ ELEV ELEC EMT ENCL ENGR EOS EQ EQPT EW (E) EXP EXT FA FD FDC
P2.01B
ACCESSIBLE PATH OF TRAVEL (FROM ACCESSIBLE PARKING TO ACCESSIBLE BUILDING ENTRANCE)
20. DO NOT DISTURB (E) BUILDING FIREPROOFING.
GENERAL DEMOLITION NOTES DEL DET DF DIA DIM DL DN DP
M2.3 M2.4 M2.5 M2.6 M3.0 M3.1 M3.2 P1.01 P1.02 P1.03 P1.04 P2.00 P2.01A
COVER SHEET NON RESIDENTIAL ALTERATIONS AND ADDITIONS CHECKLIST SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS SITE ACCESSIBILITY PLAN & DETAILS OVERALL GROUND FLOOR EXITING AND ACCESSIBILITY PLAN OVERALL SECOND FLOOR EXITING AND ACCESSIBILITY PLAN ROOF PLAN & OVERALL EXITING 2ND FLOOR PLAN CALCULATIONS OVERALL SECOND FLOOR PLAN REMODEL FLOOR & CEILING PLAN REMODEL FLOOR & CEILING PLAN REMODEL FLOOR & CEILING PLAN ENLARGED PLANS & INTERIOR ELEVATIONS ENLARGED PLANS & INTERIOR ELEVATIONS INTERIOR ELEVATIONS FINISH FLOOR PLAN & INTERIOR FINISHES DOOR SCHEDULE & DETAILS FRAMING & ROOFING DETAILS CEILING DETAILS CASEWORK AND MISC. DETAILS ACCESSIBILITY & MISC. DETAILS MECHANICAL GENERAL NOTES & ABBREVIATIONS MECHANICAL GENERAL NOTES CONT'D SCHEDULES TITLE 24 TITLE 24 TITLE 24 TITLE 24 TITLE 24 TITLE 24 TITLE 24 TITLE 24 TITLE 24 MECHANICAL OVERALL 1ST FLOOR REFERENCE MECHANICAL SECOND FLOOR PARTIAL DEMOLITION PLAN MECHANICAL SECOND FLOOR PARTIAL REMODEL FLOOR PLAN MECHANICAL ROOF PLAN MECHANICAL SUITE 240 PLAN MECHANICAL SUITE 250 PLAN MECHANICAL SUITE 260 PLAN MECHANICAL DETAILS MECHANICAL DETAILS MECHANICAL DETAILS PLUMBING LEGEND, NOTES, & CALCULATIONS PLUMBING SCHEDULES TITLE 24 TITLE 24 PLUMBING OVERALL BASEMENT PLAN (REF. ONLY) PLUMBING OVERALL FIRST FLOOR WASTE & VENT PLAN (REF. ONLY) PLUMBING OVERALL FIRST FLOOR OVERALL HOT & COLD WATER PLAN (REF. ONLY) PLUMBING OVERALL WASTE AND VENT OVERALL SECOND FLOOR DEMO PLAN PLUMBING OVERALL SECOND FLOOR. COLD & HOT WATER DEMO PLAN PLUMBING OVERALL WASTE AND VENT OVERALL SECOND FLOOR PLAN PLUMBING OVERALL COLD AND HOT WATER SECOND FLOOR PLAN PLUMBING OVERALL ROOF PLAN PLUMBING SUITE 240 WASTE & VENT PLAN PLUMBING SUITE 240 COLD & HOT WATER PLAN PLUMBING SUITE 250 WASTE & VENT PLAN PLUMBING SUITE 250 COLD & HOT WATER PLAN PLUMBING SUITE 260 WASTE & VENT PLAN PLUMBING SUITE 260 COLD & HOT WATER PLAN PLUMBING DETAILS GENERAL NOTES, SYMBOLS, ABBREVIATIONS AND SHEET INDEX SINGLE-LINE DIAGRAM LIGHTING FIXTURE SHCEDULE AND CUT SHEETS PANEL SCHEDULES TITLE 24 TITLE 24 DEMO OVERALL 2ND FLOOR PLAN DEMO POWER AND LIGHTING PLANS SUITE 240 DEMO POWER AND LIGHTING PLANS SUITE 250 DEMO POWER AND LIGHTING PLANS SUITE 260 OVERALL 2ND FLOOR PLAN POWER AND LIGHTING PLANS SUITE 240 POWER AND LIGHTING PLANS SUITE 250 POWER AND LIGHTING PLANS SUITE 260 ROOF PLAN SPECIFICATIONS SHEET ELECTRICAL DETAILS
MEDICAL OFFICE TENANT IMPROVEMENTS SUITE 240, 250, 260.
T EC E TJ
6. WORK SHALL BE CARRIED OUT IN A MANNER THAT WILL NOT IMPOSE AVOIDABLE HARDSHIP, DANGER, OR INCONVENIENCE TO PUBLIC OR STAFF. WORK SHALL BE PLANNED SO AS TO MINIMIZE SHUTDOWN TIME OR ANY SERVICE.
9. MAINTAIN UTILITIES OR OTHER SERVICE, INDICATED TO BE ABANDONED, IN SERVICE OR PROVIDE ALTERNATE MEANS OF SERVICE UNTIL NEW FACILITIES AREA PROVIDED, TESTED, AND PUT IN OPERATION.
18. CONTRACTOR SHALL DISPOSE OF ALL ITEMS - OWNER RESERVES THE RIGHT TO SELECT SPECIFIC ITEMS FOR SALVAGE - THESE ITEMS SHALL BE IDENTIFIED DURING PRE-CONSTRUCTION WALK THROUGH.
M2.2
BO UL EV AR D
4. OWNER WILL OCCUPY EXISTING BUILDING DURING LIFE OF THIS CONTRACT. SCHEDULE ALL WORK AT SUCH TIME AND IN SUCH A MANNER TO MINIMIZE INTERFERENCE TO PUBLIC, STAFF AND OWNER'S OPERATIONS. CONTRACTOR MUST OBTAIN APPROVAL OF OWNER BEFORE STARTING ANY WORK WITHIN ANY EXISTING AREA OF BUILDING.
CFOI
RECESSED FIRE EXTINGUISHER CABINET
VA LE NC IA
3. WORK IS REQUIRED TO BE PERFORMED WITHIN EXISTING BUILDING. EACH CONTRACTOR WILL HAVE ACCESS TO AREAS IN WHICH THIS WORK OCCURS.
ARCH BD BLDG BLK BLKG BTWN C CER CF CFCI
BUILDING / PAVING ELEVATION
A2.1 A3.1 A3.2 A3.3 A4.1 A4.2 A4.3 A5.1 A6.1 A7.1 A7.2 A7.3 A7.4 M1.0 M1.01 M1.1 M1.2 M1.3 M1.4 M1.5 M1.6 M1.7 M1.8 M1.9 M1.10 M2.0 M2.1
SHEET NAME
ISSUE DATE
PROJECT NAME:
. WY PK AN BE MC
8. FABRICATE AND INSTALL INTERCONNECTING PORTIONS OF THESE SYSTEMS PRIOR TO SHUT DOWN FOR FINAL CONNECTIONS.
ACOUSTICAL ADJACENT ABOVE FINISH FLOOR ALUMINUM AMERICAN NATIONAL STANDARDS INSTITUTE ARCHITECTURAL BOARD BUILDING BLOCK BLOCKING BETWEEN CHANNEL CERAMIC CUBIC FEET CONTRACTOR FURNISHED, CONTRACTOR INSTALLED CONTRACTOR FURNISHED, OWNER INSTALLED CONTROL JOINT CEILING CLEAR CONCRETE MASONRY UNIT CONCRETE CONTINUOUS CORRIDOR CLASSROOM COUNTER SUNK CENTER TO CENTER PENNY DOUBLE
CEILING HEIGHT - ABOVE FIN. FLR. ELEV. - 0'-0"
EXISTING WALL / PARTITION
2. ALL DASHED LINES INDICATE EXISTING ITEMS TO BE REMOVED (TYP. UNLESS NOTED OTHERWISE) BUT NOT LIMITED TO THE FOLLOWING: A. INTERIOR PARTITIONS (REMOVE TO STRUCTURE). B. CEILINGS - INCLUDING CUBICAL CURTAIN TRACKS, IV TRACKS, CEILING SUSPENSION SYSTEM, MISC. STEEL SUPPORTS FOR SUSPENDED EQUIPMENT, LIGHT FIXTURES, DIFFUSERS AND GRILLES. C. FLOOR FINISHES TO CONCRETE INCLUDING: CARPET, RVT, SHEET VINYL, CERAMIC TILE, ETC. GRIND SMOOTH, ROUGHEN AND/OR ETCH RO LEAVE FLOOR SUBSTRATES IN PROPER CONDITION TO RECEIVE NEW SCHEDULED FLOOR FINISH AS RECOMMENDED BY SURFACE FINISH MANUFACTURER. D. DOORS, DOOR FRAMES, WINDOW FRAMES AND GLAZING. E. FIRE EXTINGUISHER AND FIRE HOSE CABINETS. F. CABINETWORK, SHELVING , BASES. G. TOILET PARTITIONS AND ACCESSORIES. H. TACKBOARDS, MARKERBOARDS, CHALKBOARDS, AND PEGBOARDS. I. EQUIPMENT ITEMS (SEE MECHANICAL AND ELECTRICAL). J. SAW CUT & REMOVAL OF EXISTING CONCRETE SLAB FLOOR FOR UNDERGROUND UTILITY WORK.
AB ABS AC ACC STATION ACOUS ADJ AFF ALUM ANSI
PARTITION TAG
NORTH ARROW
PLAN NORTH
7. LIMIT DURATION OF EACH SUCH DISRUPTION OF SERVICE AS APPROVED BY OWNER.
DIAMETER OR ROUND PLUS/MINUS POUND OR NUMBER PERCENT AT DEGREE CENTER LINE ANGLE PROPERTY LINE ANCHOR BOLT ABSOLUTE ASPHALTIC CONCRETE ACCESSIBLE WORK
EQUIPMENT TAG
TRUE NORTH
1. ALL SCREENED/HALFTONE LINES INDICATE EXISTING ITEMS TO REMAIN (TYP., UNLESS NOTED OTHERWISE).
G0.3 G0.4 G0.5 A0.1 A1.1
A1.3
WINDOW CALLOUT
EQUIPMENT DESIGNATION
A1
LOCATION ON SHEET
DOOR CALLOUT
AA
GENERAL NOTES
Ø +/# % @ °
G0.1 G0.2
WINDOW NUMBER
AUTOMATIC SPRINKLER SYSTEMS (CALIFORNIA AMENDED)
FIRE DOOR AND OTHER OPENING PROTECTIVES 2013 ED
SHEET NUMBER
GRID BUBBLE
GRID NUMBER
A1.2 SECTION #
5
ARCHITECT
2013 CALIFORNIA PLUMBING CODE AND THE 2012 UNIFORM PLUMBING CODE
10. ANY EXISTING ELEC., PLUMB OR HVAC DEVICES OR SYSTEMS WHICH ARE NEEDED TO MAINTAIN THE OPERATIONS OF THE SYSTEM, SHALL BE CAPPED OFF OR REROUTED AS NECESSARY TO MAINTAIN SYSTEM, REGARDLESS IF INDICATED HEREIN.
PROJECT INFO & SCOPE
-1 07 - 3 1 R O F CA L I F O
Project Title:
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260 23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355 Revisions: 1 2 3 4 5
PARKING LOT
NOTE: OTHER ABBREVIATIONS USED ON THESE DRAWINGS ARE CONSIDERED STANDARDS IN THE BUILDING INDUSTRY. CONTACT ARCHITECT FOR NECESSARY CLARIFICATION.
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
Project #: CA13500.90 Date:
12/30/15
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
Drawn:
Checked: JD
Sheet Title:
COVER SHEET
SITE PLAN
1 1" = 40'-0"
SHEET INDEX
FR
G0.1
IA
6. SITE UTILITIES: THE CONTRACTOR SHALL USE EXISTING SERVICES.
2281 West 190th Street, #100 Torrance, CA 90504
7
5. CONTRACTOR SHALL USE ONLY THOSE ENTRANCES AND PARKING FACILITIES ASSIGNED BY THE BUILDING OWNER FOR SITE ACCESS. ALL MATERIAL DELIVERIES SHALL BE SCHEDULED SO AS TO MINIMIZE DISRUPTIONS TO THE BUILDING OCCUPANTS.
1 A101
1500 East Duarte Road Duarte, CA 91010-3000
N
4. ALL BUILDING SYSTEM SERVICES (IE: WATER, SANITARY, FIRE ALARM, ELECTRIC, ETC...) SHALL REMAIN IN OPERATION THROUGHOUT CONSTRUCTION. ALL NECESSARY INTERRUPTIONS FOR CONNECTION OF NEW WORK SHALL BE PERFORMED AFTER NORMAL BUSINESS HOURS OR AS AGREED TO BY BUILDING OWNER. ANY REQUIRED INTERRUPTIONS OF SERVICE SHALL BE SCHEDULED AND APPROVED BY THE BUILDING OWNER 72 HOURS IN ADVANCE. COST IMPACTS OF AFTER HOURS WORK SHALL BE ANTICIPATED AND INCLUDED IN THE BID PROPOSAL.
2013 CALIFORNIA ELECTRICAL CODE AND THE 2011 NATIONAL ELECTRICAL CODE
SECTION # SHEET DRAWN ON
SIM
24515 Kansas St. Newhall, CA 91321
C
3. PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL VERIFY LOCATION OF ALL EQUIPMENT AND UTILITY POINTS OF SERVICE.
2013 CALIFORNIA BUILDING CODE AND THE 2012 INTERNATIONAL BUILDING CODE
Intelisyn
S
2. THE CONTRACTOR AND BUILDING OWNER SHALL MEET PRIOR TO NOTICE TO PROCEED AND SHALL DOCUMENT EXISTING CONDITIONS OF THE GENERAL PROJECT AREA.
9. CONTRACTOR SHALL SCHEDULE ALL WORK TO AVOID INTERRUPTIONS TO ADJACENT AREAS. ALL DISRUPTIVE WORK SHALL BE SCHEDULED AND PERFORMED BEFORE / AFTER NORMAL BUSINESS HOURS OF THE DEPARTMENT. WORK STOPPAGE DUE TO VIBRATIONS, ETC. THAT DISTURB THE OCCUPANTS WILL NOT BE GROUNDS FOR ADDITIONAL CHARGES OR CHANGE ORDERS.
City of Hope
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
LI
1. IT IS THE INTENT OF THE ARCHITECT THAT THIS WORK BE IN CONFORMANCE WITH THE BUILDING AUTHORITIES HAVING JURISDICTION OVER THIS WORK AND OCCUPANCY. ALL CONTRACTORS SHALL EXECUTE THEIR WORK IN COMPLIANCE WITH THE CODES LISTED HEREIN. ALL WORK SHALL BE EXECUTED UNDER PROPER BUILDING PERMITS AS REQUIRED BY THE AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT.
PROJECT MANAGER
JA
23823 W VALENCIA BOULEVARD, SANTA CLARITA, CA 91355
TENANT
CIT RUS ST.
MEDICAL OFFICE TENANT IMPROVEMENT SANTA CLARITA - SUITES 240, 250, 260
OWNER Valencia Blvd. Investment Partners, LLC
(E) HANDRAIL W/ INSIDE SURFACE AT 1-1/2" CLEAR OF WALLS AND 32" ABOVE FINISHED FLOOR
FLOOR LANDING NUMBER AND BRAILLE ON BOTH JAMBS
ELEVATOR CALL
HALL LANTERN
2 ELEV. DOOR
ACCESSIBILITY NOTES
FOR (E) FLOOR DESIGNATION 6 -REF A0.1
72" MIN.
HANDRAIL
60"
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
A0.1
1. GENERAL: ALL ACCESSIBILITY REQUIREMENTS IN THE PRIMARY PATH OF TRAVEL (P.O.T.) TO THE PRIMARY ENTRANCE TO THE ALTERATION AREA APPEAR TO SUBSTANTIALLY CONFORM TO THE APPLICABLE 2013 CALIFORNIA BUILDING CODE.
FOR (E) HALL SIGNALS -REF 7
29"
2. WALKS AND SIDEWALKS: ALL WALKS AND SIDEWALKS THAT ARE INDICATED AS PATH OF TRAVEL SHALL BE BARRIER-FREE ACCESS ROUTE WITHOUT ANY ABRUPT VERTICAL CHANGES EXCEEDING 1/4 INCH AND ANY CROSS SLOPE CHANGES EXCEEDING 2% SLOPE.
A0.1
5"
4
1 1/2" MIN. FROM WALL
32" MAX. A.F.F.
42"
FOR (E) CAB DESIGNATION -REF 5
A0.1
FOR (E) ELEVATOR CONTROL PANEL -REF 8
3. STAIRS AND STEPS: ALL STAIRWAYS, HANDGRIPS, HANDRAILS AND SIGNAGE SHALL CONFORM TO CBC 11B-504. ALL STRIPING SHALL BE PROVIDED AT UPPER AND LOWER TREAD OF EACH STAIR MARKED BY CONTRASTING COLOR OF SLIP RESISTANT MATERIAL AT LEAST 2 INCHES WIDE PLACED PARALLEL TO NOSING AND/OR LANDING.
A0.1
4. WATER FOUNTAINS: ALL DRINKING FOUNTAINS SHALL CONFORM TO CBC 11B-602
NOT USED
18
(E) DRINKING FOUNTAIN FOR REFERENCE ONLY
N.T.S.
9 1/2" = 1'-0"
(E) ELEVATOR HALL CONFIGURATION FOR REFERENCE ONLY
4
(E) ELEVATOR CAB PLAN FOR REFERENCE ONLY
1" = 1'-0"
3 1/4" = 1'-0"
5/8" MIN NUMERAL HEIGHT
5. CURB RAMPS: ALL CURB CUTS AND RAMPS SHALL CONFORM TO CBC 11B-405. 6. ACCESSIBLE PARKING: EACH PARKING AREA SHALL CONFORM WITH CBC 11B-502 WITH AT LEAST ONE (1) ACCESSIBLE VAN PARKING SPACE IN EACH PARKING AREA. 7. DOOR THRESHOLDS: ALL FLOORS OR LANDINGS SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THRESHOLD OF THE DOORWAY WITH 1:2 SLOPED BEVEL FOR CHANGES FROM 1/4 TO 1/2 INCH AND WITH 1:12 SLOPED RAMP FOR CHANGES 1/2 INCH OR MORE.
*1 3
STAR ALONGSIDE MAIN EXIT FLOOR NUMBER
5
2
NUMBER 02.01
PROVIDE WORK / ITEM PAINT 4" WIDE WHITE HATCHING
3/8" MIN. SEPARATION
35" MAX. A.F.F.
48" MAX. A.F.F.
3/4" Ø CONTROL BUTTON, ILLUMINATED
NOT USED
17
NOT USED
N.T.S.
(E) ELEVATOR CONTROL PANEL FOR REFERENCE ONLY
8
TYP (E) ACCESSIBLE PARKING SIGNAGE FOR REFERENCE ONLY
3" = 1'-0"
9' - 0" MIN (E)
N.T.S.
13
9' - 0" MIN (E)
1' - 0" (E) TYP
(E) CONC CURB, TYP
16
NOT USED
N.T.S.
(E) ELEVATOR HALL SIGNALS FOR REFERENCE ONLY
7
18' - 0" (E) MIN
(E) 2% MAX SLOPE IN ANY DIRECTION AT STRIPED AREA
1/2" = 1'-0" 4' - 0" MIN (E)
N.T.S.
12
2' - 0" (E) MIN
(E) ACCESSIBLE PARKING SIGNAGE -REF 2 A0.1
Agency Approval:
(E) 4" WIDE BLUE BORDER (TYP)
5' - 0" MIN (E)
NOT USED
2
1 1/2" = 1'-0"
(E) 4" WIDE BLUE HATCHING @ 36" O.C. (E) 2% MAX SLOPE IN ANY DIRECTION AT STRIPED AREA 02.01 TYP
9' - 0" MIN (E)
5 (E) ACCESSIBLE PARKING SIGNAGE -REF 2 A0.1
Architect/Engineer of Record
C
S
JA
LI
T EC E TJ
(E) 3' SQUARE ACCESSIBLE SYMBOL (TYP)
A RCH S ED I EN A . DO T N N O
NOT USED
15
NOT USED
N.T.S.
(E) ELEVATOR FLOOR DESIGNATION FOR REFERENCE ONLY
6
9' - 0" MIN (E)
Project Title:
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
18' - 0" MIN (E)
3" = 1'-0" 4' - 0" MIN (E)
N.T.S.
11
(E) 2% MAX SLOPE IN ANY DIRECTION AT STRIPED AREA
(E) ACCESSIBLE PARKING SIGNAGE -REF 2 A0.1
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355
8' - 0" MIN (E)
(E) 2% MAX SLOPE IN ANY DIRECTION AT STRIPED AREA
Revisions:
(E) 4" WIDE BLUE HATCHING @ 36" O.C.
(E) "NO PARKING" IN 12" HIGH MIN WHITE LETTERS (TYP)
1 2 3 4 5
(E) 4" WIDE BLUE BORDER (TYP)
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
02.01 TYP
9' - 0" MIN (E)
5 (E) ACCESSIBLE PARKING SIGNAGE -REF 2 A0.1
Project #: CA13500.90 Date:
12/30/15
Drawn:
FR
Checked: JD
Sheet Title:
SITE ACCESSIBILITY PLAN & DETAILS
NOTE: NO SCOPE OF WORK REQUIRED, DETAIL PROVIDED TO DEMONSTRATE ACCESSIBILITY ONLY.
NOT USED
14 N.T.S.
NOT USED
10 N.T.S.
(E) ELEVATOR CAB DESIGNATION FOR REFERENCE ONLY
5 3" = 1'-0"
TYP (E) ACCESSIBLE PARKING FOR REFERENCE ONLY
1 1/4" = 1'-0"
A0.1
7
-1 07 - 3 1 R O F CA L I F O
N
TE
A
(E) AC PAVING
EN .
R
ST
(E) WHEELSTOP (TYP)
IA
NO. C-32176
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
ACCESSIBILITY NOTE UNLESS INDICATED OTHERWISE THEREIN, ALL ACCESSIBILITY REQUIREMENTS IN THE PRIMARY PATH OF TRAVEL (P.O.T.) FROM ACCESSIBLE PARKING AND THE PUBLIC WAY TO THE PRIMARY ENTRANCE TO THE ALTERATION AREA SUBSTANTIALLY CONFORMS TO THE 2013 CALIFORNIA BUILDING CODE PER FIELD VERIFICATION BY THE ARCHITECT.
EXITING PLAN LEGEND SCOPE OF WORK AREA
AREA NOT WITHIN SCOPE OF WORK
EXIT PATH
ACCESSIBLE PATH OF TRAVEL
6 1
2
3
4
5
AREA
AREA (SQ.FT.)
LOAD
OCCUPANT LOAD
FACTOR
7
8
9
10
11
OCCUPANT LOAD FACTOR
# OCC
NUMBER OF OCCUPANTS EXITING THRU DOOR OPENING
*.02
REQUIRED EXIT WIDTH (INCHES) 32" MIN.
WIDTH
PROVIDED EXIT WIDTH (INCHES)
PANIC
PANIC EXIT HARDWARE PROVIDED
TOTAL AREA CUMULATIVE OCCUPANT LOAD PER SUITE
# A
(E) ELEVATOR
B SUITE 130
SUITE 120
SUITE 115
SUITE 110
C REFERENCE 2ND FLOOR FOR CONTINUATION AND TRAVEL DISTANCE INFORMATION
(E) EXIT ACCESS STAIR
(E) EXIT ACCESS STAIR
Agency Approval:
REFERENCE 2ND FLOOR FOR CONTINUATION AND TRAVEL DISTANCE INFORMATION
D Architect/Engineer of Record
S
LI
C
SUITE 160
JA
SUITE 150
A RCH S ED I EN A . DO T N N O
T EC E TJ
SUITE 140
(E) ELEVATOR -REF 3 A0.1
EN .
A
7
-1 07 - 3 1 R O F CA L I F O
N
R
ST
TE
IA
NO. C-32176
Project Title:
E
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260 23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355 Revisions: 1 2 3 4 5
F
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
Project #: CA13500.90 Date:
12/30/15
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
Drawn:
FR
Checked: JD
Sheet Title:
OVERALL GROUND FLOOR EXITING AND ACCESSIBILITY PLAN OVERALL EXITING GROUND FLOOR PLAN
1 1/8" = 1'-0"
A1.1
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
ACCESSIBILITY NOTE UNLESS INDICATED OTHERWISE THEREIN, ALL ACCESSIBILITY REQUIREMENTS IN THE PRIMARY PATH OF TRAVEL (P.O.T.) FROM ACCESSIBLE PARKING AND THE PUBLIC WAY TO THE PRIMARY ENTRANCE TO THE ALTERATION AREA SUBSTANTIALLY CONFORMS TO THE 2013 CALIFORNIA BUILDING CODE PER FIELD VERIFICATION BY THE ARCHITECT.
EXITING PLAN LEGEND SCOPE OF WORK AREA
AREA NOT WITHIN SCOPE OF WORK
EXIT PATH
ACCESSIBLE PATH OF TRAVEL
6 1
2
3
4
AREA
AREA (SQ.FT.)
LOAD
OCCUPANT LOAD
FACTOR
5
7
8
9
10
11
OCCUPANT LOAD FACTOR
# OCC
NUMBER OF OCCUPANTS EXITING THRU DOOR OPENING
*.02
REQUIRED EXIT WIDTH (INCHES) 32" MIN.
WIDTH
PROVIDED EXIT WIDTH (INCHES)
PANIC
PANIC EXIT HARDWARE PROVIDED
TOTAL AREA CUMULATIVE OCCUPANT LOAD PER SUITE
# A
B
SUITE 230
SUITE 220
SUITE 215
(E) DRINKING FOUNTAIN -REF 9 A0.1
C
SUITE 210 HD STORAGE
32
32
84 SF
48
36
No
No
No
150 SF EQUIPMENT ROOM
2
5
105 SF
MA
MA
2
100 SF
100 SF
100
1
1
100
100
300
HALLWAY
100
RECEPTION
EXIT = 138' - 6"
TRAVEL DISTANCE TO
112 SF
112 SF
112 SF
116 SF
2
2
100
2 100
100
300
2
EXAM 2
100
112 SF 2
CLEAN 110 SF 1 300
67 SF
DIRECTOR OFFICE
2 100
ANTE ROOM STAFF RESTROOM
PATIENT RESTROOM
SOILED UTILITY
100
101 SF 2
PF
INFUSION 7 111 SF
HALLWAY
INFUSION 8
EXIT = 233' - 10"
PROCEDURE 1
PROCEDURE 2
150 SF
159 SF
2
2
100
100
100
NO. C-32176
100
81 SF
INFUSION 1
1
INFUSION 6
80 SF
100
80 SF
118 SF
1
2
100
100
100
INFUSION 2
INFUSION 5
80 SF
80 SF
1
A RCH S ED I EN A . DO T N N O
2
TRAVEL DISTANCE TO TRAVEL DISTANCE TO
Architect/Engineer of Record
1
100
SURGERY SCHEDULER
110 SF HALLWAY
SUPPLIES
ELEVATOR
EXIT = 273' - 4"
100
EXAM 6
1
15
2
SOILED 164 SF
14
INFUSION AREA
NURSE STATION
365 SF
185 SF
4
2
INFUSION 4
100
100
80 SF
CONFERENCE ROOM
100
416 SF
389 SF
INFUSION 3
5
26
80 SF
100
15
1
1
100
100
-1 07 - 3 1 R O F CA L I F O
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
1
MD WORKROOM
EN .
Project Title:
1
SUITE 260
TE
A
300
EXAM 1
300
209 SF
R
1
EXAM 3
1
ST
56 SF
EXAM 4
100
100
143 SF
143
73 SF
T EC E TJ
100
PATIENT RESTROOM
99 SF
SUITE 250
227 SF
300
5
15
300
3
EXAM 5
38
IT/IDF CLOSET
1
1
SUPPLY STORAGE
E
100
SUITE 240
130 SF
2
1
100
MECH. RM. JAN.
1
1
STAFF BREAK RM.
IA
EXAM 7
565 SF
NON-HD STORAGE
7
D
RESEARCH OFFICE
138 SF
105 SF
2
5
80 SF
5
N
114 SF
67 SF
WAITING
OFFICE
HD MIXING
C
EQUIPMENT ROOM
CONSULT
Agency Approval:
300
NON-HD MIXING
S
36
1
STAIRS 2
LI
STAIRS 1
32
38
JA
53
52
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355
100
Revisions: 1 2 3 4 5
F
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
Project #: CA13500.90 Date:
12/30/15
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
Drawn:
FR
Checked: JD
Sheet Title:
OVERALL SECOND FLOOR EXITING AND ACCESSIBILITY PLAN OVERALL EXITING SECOND FLOOR PLAN
1 1/8" = 1'-0"
A1.2
OCCUPANCY LOAD CALCULATIONS ROOM NUMBER
NAME
AREA
OCCUPANCY OCCUPANCY (CBC TABLE 1015.1)
Table 10-A Minimum Egress Requirements
SINGLE EXIT MAX OCCUPANT LOAD
OCCUPANT LOAD FACTOR
OCCUPANT LOAD
EXITS REQUIRED 2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
201 CLEAN 202 SOILED 203 PROCEDURE 1 204 PROCEDURE 2 205 EXAM 6 206 EXAM 5 210 EQUIPMENT ROOM 211 RESEARCH OFFICE 212 EXAM 7 213 MA 214 MA 215 EXAM 4 216 EXAM 3 217 EXAM 2 218 EXAM 1 220 CONSULT 221 EQUIPMENT ROOM 222 OFFICE 223 RECEPTION 224 SURGERY SCHEDULER 225 MD WORKROOM 226 CONFERENCE ROOM 227 WAITING 229 DIRECTOR OFFICE 232 STAFF BREAK RM. 233 IT/IDF CLOSET 236 ANTE ROOM 237 NON-HD MIXING 238 HD MIXING 239 NURSE STATION 240 INFUSION 1 241 INFUSION 2 242 INFUSION 3 243 INFUSION 4 244 INFUSION 5 245 INFUSION 6 246 INFUSION 7 247 INFUSION 8 248 SUPPLIES 249 HD STORAGE 250 NON-HD STORAGE 251 INFUSION AREA Grand total
5
HVAC UNIT
GASKET
UNIT PERIMETER SUPPORT HOLD-DOWN & UNIT ATTACHMENT
UNIT FRAME WD NAILER ROOF CURB -REF MECH
CONT 18 GA GALV STL FLASHING
CURB ATTACHMENT -REF STRUCT CONC HOUSEKEEPING PAD -REF STRUCT
NEOPRENE WASHER AT STL FLASHING ATTACHMENT CANT STRIP CAP FLASHING BASE FLASHING
(E) CONC ROOF SLAB
110 SF 164 SF 150 SF 159 SF 110 SF 116 SF 130 SF 150 SF 105 SF 100 SF 100 SF 112 SF 112 SF 112 SF 112 SF 114 SF 105 SF 138 SF 227 SF 118 SF 416 SF 389 SF 565 SF 143 SF 209 SF 99 SF 101 SF 67 SF 80 SF 185 SF 80 SF 80 SF 80 SF 80 SF 80 SF 80 SF 111 SF 81 SF 67 SF 84 SF 73 SF 365 SF
1 Accessory storage areas, mechanical equipment room 1 Accessory storage areas, mechanical equipment room 9 Business area 9 Business area 9 Business area 9 Business area 1 Accessory storage areas, mechanical equipment room 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 1 Accessory storage areas, mechanical equipment room 9 Business area 9 Business area 9 Business area 9 Business area 7 Assembly without fixed seats, Unconcentrated (tables and chairs) 7 Assembly without fixed seats, Unconcentrated (tables and chairs) 9 Business area 7 Assembly without fixed seats, Unconcentrated (tables and chairs) 1 Accessory storage areas, mechanical equipment room 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 9 Business area 1 Accessory storage areas, mechanical equipment room 1 Accessory storage areas, mechanical equipment room 1 Accessory storage areas, mechanical equipment room 9 Business area
2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B 2B
49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49 49
300 300 100 100 100 100 300 100 100 100 100 100 100 100 100 100 300 100 100 100 100 15 15 100 15 300 100 100 100 100 100 100 100 100 100 100 100 100 300 300 300 100
1 1 2 2 2 2 1 2 2 2 1 2 2 2 2 2 1 2 3 2 5 26 38 2 14 1 2 1 1 2 1 1 1 1 1 1 2 1 1 1 1 4 144
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
SLAB PENETRATION NOTE 1. CONTRACTOR SHALL X-RAY ROOF AND FLOOR SLABS TO LOCATE (E) REINFORCING. (E) REINFORCING SHALL NOT BE DISTURBED. 5
5
5
ROOFING AT RTU
3
OCCUPANCY LOAD CALCULATIONS
2 N.T.S.
3" = 1'-0"
5
1
2
3
4
5
6
7
8
9
10
11
Agency Approval:
C
Architect/Engineer of Record 15 A7.1
(E) ROOFING
S
JA
LI
(E) HVAC UNIT
A RCH S ED I EN A . DO T N N O
T EC E TJ
C
(E) DUCTWORK
D
7
-1 07 - 3 1 R O F CA L I F O
N
A
(E) CONC HOUSEKEEPING PAD
EN .
R
ST
TE
IA
NO. C-32176
Project Title:
14 A7.1
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
E
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355 Revisions: 1 2 3 4 5
14 A7.1
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
F
Project #: CA13500.90 Date:
12/30/15
Drawn:
FR
Checked: JD
Sheet Title:
ROOF PLAN & OVERALL EXITING 2ND FLOOR PLAN CALCULATIONS PARTIAL ROOF PLAN
1 3/32" = 1'-0"
A1.3
MARK
PROCURE
EQUIPMENT
ROOM
MANUFACTURER
SIZE (LxDxH)
MODEL
5
UTILITIES POWER
NOTES
PH / DATA
A
BIOSAFETY CABINET
OFOI
HD MIXING ROOM 238
BAKER COMPANY
STERILGARD SG303 CLASS II TYPE A2
35.625" x 30.625" x 61.75"
100 V AC, 20A, 50/60 Hz, NEMA 5-20R
N/A
B
INVENTORY MANAGEMENT
OFOI
HD STORAGE 249, NON-HD STORAGE 250
NUCLEUS INVENTORY
NUCLEUS INVENTORY
26.5" x 29.5" x 78"
120 V, 3A
YES
-
C
-80 FREEZER
OFOI
SOILED 202
THERMO SCIENTIFIC
ULT185-5-A
15.3" x 12" x 9.3"
115V, 60 Hz
N/A
-
-
-
N/A
-
-
-
-
-
D
-
-
-
-
-
120 V, 60 Hz
W/ FLEXAIRE EXHAUST CONNECTION & ALARMS, ADJ. BASE
E
CENTRIFUGE
OFOI
SOILED 202
THERMO SCIENTIFIC
SORVALL ST 8R
18.1" x 26.4" x 12.6"
F
REFRIGERATOR
OFOI
STAFF BREAK ROOM 232
WHIRLPOOL
WRT 511 5ZDM
32.75" x 32.5" x 65.5"
G
CLEAN BENCH
OFOI
NON-HD MIXING 237
BAKER COMPANY
EDGEGARD IV22
22" x 27" x 43"
115 V, 60 Hz, 1-PH
N/A
-
H
PHARMACY REFRIGERATOR
OFOI
HD STORAGE 249
PANASONIC
MPR-721R-PA
30.3" X 32.7" X 77"
115 V, 60 Hz, 1-PH, NEMA 5-15R
YES
-
I
UPS
OFOI
HD STORAGE 249, NON-HD STORAGE 250, SOILED 202 APC
SMART UPS RT 3000VA
5.1" X 26" X 17"
120 V, NEMA L5-30R
N/A
-
J
WORKSTATION ON WHEELS
OFOI
REF FLOOR PLAN
RUBBERMAID HEALTHCARE
M38
17" X 17" X VARIES
120 V, 60 Hz
YES
-
K
SCALE
OFOI
REF FLOOR PLAN
SCALETRONIX
5002
18" X 19.5" X52.5"
N/A
NO
-
L
UNDERCOUNTER PHARMACY REFRIGERATOR
OFOI
HD STORAGE 249, NON-HD STORAGE 250
SANYO
SR-L6111W
23.6" X 22.5" X 34.5"
120 V, 60 Hz, NEMA 5-15 R
N/A
-
M
EXAM TABLE
OFOI
EXAM & PROCEDURE ROOMS
MIDMARK CORP
222-016-232, 002-0871-232 SHADOW
28.5" X 76" X 37"
115 V, 50/60 Hz
N/A
-
N
INFUSION CHAIR
OFOI
INFUSION 1 - 6
WINCO
6940-72
33.5" X 76.5" X 48.5"
120 V
N/A
-
O
-
-
P
BLANKET WARMER
OFOI
Q
-
-
-
-
-
CONTINENTAL METAL PRODUCTS
NURSE STATION - 239 -
-
-
DSW 2AE-2-24
-
30" X 27" X 74"
-
-
-
-
N/A
-
-
-
110 V-127 V, 50/60 Hz, 15 A
YES
-
120 V, 60 Hz, 1-PH
-
-
R
PRINTER / FAX
OFOI
RECEPTION 223 & NURSE STATION 239
XEROX
7845
S
AUTOCLAVE
OFOI
CLEAN - 201
MIDMARK
M11-022
17.8" X 23.8" X 17.8"
115 V, 50/60 Hz, 15 A, 1-PH
N/A
T
ANALYZER
OFOI
CBC AREA
SYSMEX
XS-1000I
16.7" X 24.2" X 15.9"
TBD
YES
U
UNDERCOUNTER REFRIGERATOR
OFOI
NUTRIENT BAR
GE
GME04GLHLB
19.625" X 21.25" X 33.875"
115 V, 20 A, 60 Hz
NO
-
V
STRETCHER
OFOI
INFUSION 7
STRYKER
PRIME ELECTRIC 5TH WHEEL
86" X 38" X 34"
120 V
NO
-
W
MICROWAVE
OFOI
STAFF BREAK ROOM 232
WHIRLPOOL
WMC30516AS
21.75" X 17.25" X 13"
120 V, 20 A, 60 Hz
NO
-
-
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
OVERALL FLOOR PLAN LEGEND
PLUMBING FIXTURE CALCULATIONS
AREA NOT WITHIN SCOPE OF WORK
8,512 USABLE SQ.FT./200 OCC. LOAD = 42.56 = 43 OCCUPANTS 43 OCCUPANTS/2 (50% FOR MALE/50% FOR FEMALE) = 22 MALE/ 22 FEMALE
SCOPE OF WORK AREA TYPE OF BUILDING
FLOOR
OCCUPANT LOAD MALE
PUBLIC OR PROFESSIONAL OFFICE
2ND FLOOR
REQUIRED FIXTURES
FEMALE
22
MALE WC: UR: LAV:
22
BATHTUB/ SHOWERS
FEMALE
1:1-50 WC: 1:1-100 LAV: 1:1-75
TOTAL FIXTURES PROVIDED
1:1-15 1:1-50
N.R.
DRINKING FOUNTAIN 1:1-250
NOTES/ EXCEPTIONS
UNISEX WC: UR: LAV:
(N) PARTITION
3 0 3
(E) ITEM
REQUIRES COMPUTER MONITOR & KEYBOARD
3
PLUMBING FIXTURE CALCULATIONS
12" = 1'-0"
2
3
4
5
(E) PARTITION
(N) ITEM
EQUIPMENT SCHEDULE
1
DESCRIPTION
SYMBOL
PROPOSED CLINIC OCCUPANCY CATEGORY: GROUP 'B' OCCUPANCY = 200
6
2 12" = 1'-0"
7
8
9
10
11
A
B
SUITE 230
SUITE 220
SUITE 215
C SUITE 210
STAIRS 1
STAIRS 2
OFFICE
221
222
MECH. RM.
5
JAN.
STAFF BREAK RM. IT/IDF CLOSET
D
232
Architect/Engineer of Record
233
211
WAITING
HALLWAY
SUITE 240
NON-HD MIXING
227
219
C
ELEVATOR
212
DIRECTOR OFFICE
RECEPTION
236
PATIENT RESTROOM
SOILED UTILITY
NON-HD STORAGE
PF
235
231
TE
A
SUITE 250
230
NO. C-32176
248
249
ANTE ROOM
EN .
R
229
SUPPLIES
ST
223
237
STAFF RESTROOM
HD STORAGE
A RCH S ED IT N E A . DO N N O
S
EXAM 7
238
LI
214
JA
213
HD MIXING
T EC E TJ
RESEARCH OFFICE
MA
INFUSION 7
250
-1 07 - 3 1 R O F CA L I F O
246
EQUIPMENT ROOM
PATIENT RESTROOM
210
209
EXAM 5 206
EXAM 4 215
EXAM 3 216
Project Title: EXAM 2
EXAM 1
217
218
HALLWAY 234
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
INFUSION 8 247
E
SUPPLY STORAGE
5
208
HALLWAY
202
207
INFUSION 6
240
245
SUITE 260 INFUSION AREA
224
EXAM 6 SOILED
INFUSION 1
SURGERY SCHEDULER
INFUSION 2
INFUSION 5
241
CLEAN 201
PROCEDURE 1 203
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355
251
205
MD WORKROOM
CONFERENCE ROOM
225
226
Revisions:
244
1 2 3 4 5
NURSE STATION 239
PROCEDURE 2
INFUSION 3
INFUSION 4
242
243
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
204
F Project #: CA13500.90 Date:
12/30/15
Drawn:
FR
Checked: JD
2 A3.2
REMODEL REMODEL FLOOR CEILING PLAN PLAN
SUITE 260
1 A3.2
SUITE 250
REMODEL REMODEL FLOOR CEILING PLAN PLAN
SUITE 250
2 A3.1
SUITE 240
Sheet Title: 1 A3.1
1 A3.3
OVERALL SECOND FLOOR PLAN
2 A3.3
REMODEL REMODEL FLOOR CEILING PLAN PLAN
OVERALL SECOND FLOOR PLAN
1 1/8" = 1'-0"
A2.1
IA
220
7
5
5
EQUIPMENT ROOM
N
CONSULT
MA
Agency Approval:
REMODEL CEILING NOTES 1
2
3
4
1. REFER TO SCHEDULE OF FINISHES FOR ADDITIONAL INFORMATION. 2. CEILING GRID SHALL BE CENTERED WITHIN THE ROOM, U.N.O. 3. ALL CEILINGS ARE 9' - 0" AFF U.N.O. 2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
CEILING PLAN LEGEND SYMBOL
DESCRIPTION
DETAIL
8' - 6"
D
MA
TYP @ EA. 12.01 WINDOW
212
214
CURTAIN & TRACK (15/A7.2) ROLLER WINDOW SHADES (REF FINISH SCHEDULE) (16/A7.2)
SCOPE OF WORK AREA
HALLWAY 219
9' - 0"
1 / A7.2
24" x 48" ACOUSTICAL CEILING TILE
RESEARCH OFFICE
PROVIDE WORK / ITEM
MA
213
SUITE 240
EXAM 7
NUMBER 10.03 12.01
AREA NOT WITHIN SCOPE OF WORK 5
KEYNOTE LEGEND
5
211
RECESSED DOWNLIGHT
PATIENT RESTROOM
EQUIPMENT ROOM
LIGHT FIXTURES PER ELEC
12 / A7.2
MECHANICAL DIFFUSERS PER MECH
10 / A7.2 11 / A7.2
209
EXIT SIGN
210
8' - 0"
EXAM 5
8' - 0"
206
EXAM 4
EXAM 3
EXAM 2
215
216
217
8' - 0"
E
SUPPLY STORAGE
SOILED
208
202
EXAM 6
5
205
HALLWAY
2 / A3.2
207
10.03
10.03
PROCEDURE 1
PROCEDURE 2
203
204
SUITE 250 - REFER TO
CLEAN 201
F
REMODEL CEILING PLAN - SUITE 240
KEY PLAN
2 3/16" = 1'-0"
REMODEL FLOOR PLAN NOTES 1
2
3
4
1. ALL WALLS ARE TO BE TYPE 1A UNLESS NOTED OTHERWISE. REFER TO WALL TYPES. 2. WALL SHALL TERMINATE AT (E) WINDOW MULLIONS AS INDICATED.
6' - 0"
REMODEL FLOOR PLAN LEGEND
6' - 2"
DESCRIPTION
2' - 1"2' - 11 1/2"
11' - 8"
5' - 6"
3' - 6"
3' - 1"
206
2A
EXAM 4
EXAM 3
EXAM 2
215
216
217
1A
2A
1B
1C
1 / A7.1
NO. C-32176
2 / A7.1
11 /A4.3
11' - 10"
208A
205
5
HALLWAY
202
207
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355
3 /A4.3
1 /A4.3
S 1A
PROCEDURE 1
PROCEDURE 2
203
204
Revisions: 1 2 3 4 5
SUITE 250 - REFER TO
1A
1 / A3.2
202A
201
-1 07 - 3 1 R O F CA L I F O
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
10' - 0"
EXAM 6
EN .
Project Title:
2A
2A
SOILED
11' - 5"
GLUE 5/8" GYP BD TO (E) CONC COLUMN
205A
2A
CLEAN
10' - 5"
SUPPLY STORAGE 208
6 /A4.3
5 /A4.3
3A
204A
5' - 4"
4 /A4.3
2A
203A
E
TE
A
206A E
A RCH S ED I EN A . DO T N N O
R
2A
2A
EXAM 5
5' - 0"
5
ST
2A
C
2' - 4"
11' - 4"
210
DETAIL
IA
2A
SYMBOL
Architect/Engineer of Record
7
218A
217A
FEC
210A 8' - 2"
WALL TYPES
T EC E TJ
EQUIPMENT ROOM
13 / A7.4
FIRE EXTINGUISHER CABINET
216A
209
WALL TYPES
FEC
10 /A4.3 215A
2A
209A
5' - 4"
211A
1A
1 A4.1
4 A4.1
(N) PARTITION
N
HALLWAY 219
PATIENT RESTROOM
220A
SIM
C
13 /A4.3
13 /A4.3
(E) PARTITION
LI
SUITE 240
214
S
212A
211
K
14 /A4.3
Agency Approval: SCOPE OF WORK AREA
JA
212
MA
DETAIL
AREA NOT WITHIN SCOPE OF WORK
6' - 10"
EXAM 7
RESEARCH OFFICE
3A
12 /A4.3 SIM OPP HAND
5
3A
12 /A4.3
9' - 6"
213
SIM
MA
12 /A4.3
3A
3A
3A SIM 12 /A4.3 OPP HAND
219A
3' - 0"
SYMBOL
D
SUITE 240 AREA OF WORK
F
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
Project #: CA13500.90 Date:
15' - 5"
12/30/15
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
Drawn:
FR
Checked: JD
Sheet Title:
REMODEL FLOOR & CEILING PLAN
REMODEL FLOOR PLAN - SUITE 240
1 3/16" = 1'-0"
A3.1
5
REMODEL CEILING NOTES
7
1. REFER TO SCHEDULE OF FINISHES FOR ADDITIONAL INFORMATION.
5
2. CEILING GRID SHALL BE CENTERED WITHIN THE ROOM, U.N.O. 3. ALL CEILINGS ARE 9' - 0" AFF U.N.O.
CONSULT
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
8' - 6"
220
EQUIPMENT ROOM 8' - 0"
221
MECH. RM.
CEILING PLAN LEGEND
JAN.
OFFICE
WAITING
222
227
SYMBOL
DESCRIPTION
KEYNOTE LEGEND
DETAIL NUMBER
D
05.01 10.01 10.02 12.01
AREA NOT WITHIN SCOPE OF WORK
SCOPE OF WORK AREA
PROVIDE WORK / ITEM PROVIDE BACKING FOR TV MOUNTING 5 OCCUPANT LOAD SIGN (3/A7.4) ASSISTIVE LISTENING SIGN (12/A7.4) ROLLER WINDOW SHADES (REF FINISH SCHEDULE) (16/A7.2)
HALLWAY 219
RECEPTION 223
1 / A7.2
24" x 48" ACOUSTICAL CEILING TILE
9' - 0"
RECESSED DOWNLIGHT 8' - 0" 9' - 0"
5 EXAM 2
EXAM 1
217
218
12 / A7.2
MECHANICAL DIFFUSERS PER MECH
10 / A7.2 11 / A7.2
EXIT SIGN
5
SUITE 250
5
5
LIGHT FIXTURES PER ELEC
E SURGERY SCHEDULER
CONFERENCE ROOM
224
226
2 / A3.3
2 / A3.1
TYP @ EA. 12.01 WINDOW
MD WORKROOM
SUITE 260 - REFER TO
SUITE 240 - REFER TO
225
F
REMODEL CEILING PLAN - SUITE 250
KEY PLAN
2 3/16" = 1'-0"
5 10' - 9"
7' - 11"
6
2' - 11"
REMODEL FLOOR PLAN NOTES
7
1. ALL WALLS ARE TO BE TYPE 1A UNLESS NOTED OTHERWISE. REFER TO WALL TYPES.
6' - 2 1/2"
2. WALL SHALL TERMINATE AT (E) WINDOW MULLIONS AS INDICATED.
EQUIPMENT ROOM
4' - 0"
JAN.
MECH. RM.
220
227A
CONSULT
REMODEL FLOOR PLAN LEGEND
3A OFFICE
221
3A
DESCRIPTION
SYMBOL
5
222
D
SUITE 250 AREA OF WORK
DETAIL
05.01 AREA NOT WITHIN SCOPE OF WORK
Agency Approval:
2' - 11"
(N) PARTITION FEC
WALL TYPES
218
5' - 3"
13' - 2"
11 1/2"
LI
5
1A
05.01 226A
2 / A7.1
05.01
GLUE 5/8" GYP BD TO (E) CONC COLUMN
EN .
-1 07 - 3 1 R O F CA L I F O
Project Title:
SURGERY SCHEDULER
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
10' - 11"
224
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355
225
226
Revisions: 1 2 3 4 5
SUITE 260 - REFER TO
CONFERENCE ROOM
18 /A4.3
MD WORKROOM
1 / A3.3
17 /A4.3
7' - 3"
1 / A3.1 SUITE 240 - REFER TO
TE
A
225A
NO. C-32176 R
10.01 10.02
5' - 0"
1 / A7.1
ST
3A
7' - 10"
1C
234A 2A
E 11' - 5"
1B
IA
217
224A
EXAM 1
5 219B
A RCH S ED I EN A . DO T N N O
T EC E TJ
SUITE 250
5
DETAIL
7
SYMBOL
Architect/Engineer of Record
C
2A 5
EXAM 2
13 / A7.4
FIRE EXTINGUISHER CABINET
N
223
S
1 A4.2
RECEPTION
8' - 2"
FEC
218A
4' - 9 3/4"
WALL TYPES
JA
219
(E) PARTITION
R
2A HALLWAY
217A
SCOPE OF WORK AREA
227
222A
K
221A
220A
WAITING
F
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
Project #: CA13500.90 Date:
12/30/15
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
Drawn:
FR
Checked: JD
Sheet Title:
REMODEL FLOOR & CEILING PLAN
REMODEL FLOOR PLAN - SUITE 250
1 3/16" = 1'-0"
A3.2
REMODEL CEILING NOTES 7
8
9
10
11
1. REFER TO SCHEDULE OF FINISHES FOR ADDITIONAL INFORMATION. 2. CEILING GRID SHALL BE CENTERED WITHIN THE ROOM, U.N.O. 3. ALL CEILINGS ARE 9' - 0" AFF U.N.O.
SUITE 210
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
CEILING PLAN LEGEND
IT/IDF CLOSET
SYMBOL
DESCRIPTION
KEYNOTE LEGEND
DETAIL NUMBER
233
STAFF BREAK RM.
D
AREA NOT WITHIN SCOPE OF WORK
8' - 6"
05.01 06.04 10.03 12.01
232
10' - 0"
SCOPE OF WORK AREA
5
PROVIDE WORK / ITEM PROVIDE BACKING FOR TV MOUNTING GROMMET CURTAIN & TRACK (15/A7.2) ROLLER WINDOW SHADES (REF FINISH SCHEDULE) (16/A7.2)
HD MIXING 238
ELEVATOR
237
DIRECTOR OFFICE
SOILED UTILITY
8' - 0"
HD STORAGE 249
10' - 0"
8' - 0"
231
1 / A7.2
24" x 48" ACOUSTICAL CEILING TILE
NON-HD MIXING
ANTE ROOM
248
RECESSED DOWNLIGHT
8' - 0"
NON-HD 8' - 0" STORAGE
236
229
SUPPLIES
LIGHT FIXTURES PER ELEC
12 / A7.2
MECHANICAL DIFFUSERS PER MECH
10 / A7.2 11 / A7.2
250
STAFF RESTROOM
PATIENT RESTROOM
230
235
8' - 0" 10.03
INFUSION 7 246
EXIT SIGN
9' - 6" 9' - 6"
SUITE 260
INFUSION AREA 251
E 10.03
10.03 17 A7.2
INFUSION 1
INFUSION 6
240
245
10.03
10.03
2 / A3.2
9' - 6" INFUSION 2
8' - 6"
9' - 6"
241
INFUSION 5
17
244
SUITE 250 - REFER TO
A7.2 10.03
12.01 TYP @ EA. WINDOW
10.03
17 A7.2
INFUSION 3
NURSE STATION
INFUSION 4
239
243
242
F
REMODEL CEILING PLAN - SUITE 260
KEY PLAN
2 3/16" = 1'-0"
7
8 9' - 0"
4' - 6 1/2"
9
5' - 6"
8' - 2 1/2"
5' - 0"
3' - 6"
10 8' - 0"
1' - 7"
9' - 11"
REMODEL FLOOR PLAN NOTES
11
2' - 7 3/4"
5' - 2"
1. ALL WALLS ARE TO BE TYPE 1A UNLESS NOTED OTHERWISE. REFER TO WALL TYPES.
10' - 0"
STAFF BREAK RM.
8 /A4.1 HD MIXING
1' - 8" 2' - 4"
U
250A
NON-HD STORAGE
A7.1
250
B
WALL TYPES
7 /A4.3 INFUSION 7 246
SYMBOL
5
Architect/Engineer of Record
DETAIL
A RCH S ED I EN A . DO T N N O
I
1A 10' - 0"
1B
1C
1 / A7.1
NO. C-32176
246A TE
A
2 / A7.1
EN .
R
2A
INFUSION 8
20
240
SUITE 260
245
Project Title:
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
244
241
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355
8' - 0"
INFUSION 5
Revisions:
2 A4.2
INFUSION 4 NURSE STATION 239
243
1 2 3 4 5
8' - 0"
R 3' - 0"
GLUE 5/8" GYP BD TO (E) CONC COLUMN
A7.1
INFUSION 2
242
3A
251
9' - 0"
7' - 11 3/4" 8' - 0 1/4"
1 / A3.2 SUITE 250 - REFER TO
INFUSION AREA
INFUSION 6
8' - 0"
INFUSION 1
INFUSION 3
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
Project #: CA13500.90 5' - 0"
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
P
F 10' - 0"
-1 07 - 3 1 R O F CA L I F O
9 /A4.3
K
8' - 0"
8' - 0"
E
19 /A4.3
247
IA
SIM OPP HAND
7
17 /A4.2
C
7' - 6"
15 /A4.1
13 / A7.4
FIRE EXTINGUISHER CABINET
ST
FEC
FEC
N
2A
WALL TYPES
20
8' - 1"
234
2 A4.1
22 /A4.3
L
24 /A4.3
5' - 3 1/2"
2 A4.1
HALLWAY
SIM OPP HAND
1B
16 /A4.2
(N) PARTITION
T EC E TJ
235A
06.04
248
JA
235
248A
249A
249
5 /A4.1 PF
T
(E) PARTITION
SUPPLIES HD 17 /A4.2 STORAGE
7' - 4"
PATIENT RESTROOM
H
1B
236A
25 /A4.1
231
FEC 5' - 3 1/2"
ANTE ROOM 236
B
I
10 /A4.1
237A
231A
229A
229
230A
8' - 6"
230
SOILED UTILITY
237
SCOPE OF WORK AREA L
1C
NON-HD 3 /A4.1 MIXING
4' - 8 1/2"
STAFF RESTROOM
G
ELEVATOR
232A
Agency Approval:
5 1B
238A
W F
AREA NOT WITHIN SCOPE OF WORK
A 238
DETAIL
LI
234B
21 /A4.3
11' - 7"
232
DIRECTOR OFFICE
DESCRIPTION
SYMBOL
8 /A4.3
233
3' - 0"
12' - 2"
D
REMODEL FLOOR PLAN LEGEND
S
05.01
IT/IDF CLOSET
SUITE 260 AREA OF WORK
20 /A4.3
233A
2. WALL SHALL TERMINATE AT (E) WINDOW MULLIONS AS INDICATED.
5' - 0"
10' - 0"
Date:
12/30/15
Drawn:
FR
Checked: JD
Sheet Title:
REMODEL FLOOR & CEILING PLAN
REMODEL FLOOR PLAN - SUITE 260
1 3/16" = 1'-0"
A3.3
5 3' - 0" CDS 302 5
5
8 5
A7.3
PASS-THRU WINDOW REF4 A6.1 2' - 0"
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
06.02 H
22.05
27" MIN CLR
06.02
3' - 0" CDS 155
09.03
08.01
NUMBER
F
22.02
2' - 10"
G
08.01
7' - 4"
2' - 6"
F H
KEYNOTE LEGEND
G
06.02
34" MAX
06.02
09.03
09.03
1 A7.3
5
SOILED UTILITY 231
25
NOT USED
20
ANTE ROOM - ELEV C
N.T.S.
1/4" = 1'-0"
15
ANTE ROOM - ELEV B
1/4" = 1'-0"
10 1/4" = 1'-0"
1/4" = 1'-0"
5' - 0"
5
2' - 6" 2' - 6" CDS 302 CDS 302 (E) STOREFRONT
8 A7.3
5
5
3' - 10"
5
10.05 10.04
TYP EXAM ELEVATION - D
24
09.01 26.02
09.01
TYP EXAM ELEVATION - C
1/4" = 1'-0"
19
TYP EXAM ELEVATION - B
1/4" = 1'-0"
10.03
19 /A4.1
26.02
14
M
24 /A4.1 J
09.01
2' - 6" CDS 272
2' - 6" OPEN
4 A7.3
2 A7.3
9
TYP EXAM ELEVATION - A
1/4" = 1'-0"
1/4" = 1'-0" 2' - 6" 2' - 6" CDS 302 CDS 302 8 A7.3
1/4" = 1'-0" 5
3' - 0" CDS 302
5
8 A7.3
8 A7.3
06.03
06.02
5
NOTE: PROVIDE LOCKS ON UPPER CABINETS - HD AND NON-HD MIXING ROOMS SHALL RECEIVE UNIQUE KEY
NOT USED
23
NOT USED
N.T.S.
18
NOT USED
N.T.S.
13
2' - 6"
SS1
06.03
2' - 10"
3' - 0" CDS 300
5' - 0" CDS 300
5
2' - 0"
SS1
2' - 10"
2' - 0"
2' - 6"
06.02
2' - 10"
7' - 4" 5
4
ENLARGED FLOOR PLAN - TYP EXAM
7' - 4"
26.02
14 /A4.1 9 /A4.1
G
H
09.01
3' - 2"
1' - 6"
2' - 6" 26.02
F 3' - 0" MIN
2' - 0"
26.02
06.03
2' - 10"
7' - 4"
7' - 4"
2' - 0"
2' - 6"
10.03
26.01
2' - 10"
TYP
30"
26.02
5 FIBERGLASS REINFORCED PLASTIC PANEL (FRP) PROVIDE CABINET LOCK 5 PASS-THRU WINDOW 4" RESILIENT WALL BASE (REF FINISH SCHEDULE) 5 INTEGRAL COVE BASE (19/A7.1) CURTAIN & TRACK (15/A7.2) GLOVES BOX OFCI SHARPS BOX OFCI LAVATORY, COORDINATE WITH PLUMBING WATER CLOSET, COORDINATE WITH PLUMBING RECESSED, PULL-DOWN EYE WASH (REF PLUMBING) LIGHT SWITCH -REF ELEC POWER RECEPTACLE -REF ELEC 36" GRAB BAR (11/A7.4) 42" GRAB BAR (11/A7.4) WALL MIRROR (11/A7.4) PAPER TOWEL / TRASH RECEPTACLE (11/A7.4) SEAT COVER DISPENSER (11/A7.4) SOAP DISPENSER (11/A7.4) SANITIZER DISPENSER (11/A7.4) PAPER TOWEL DISPENSER (11/A7.4) TOILET PAPER DISPENSER (11/A7.4) FEMININE NAPKIN DISPOSAL (11/A7.4)
8 A7.3
10.03
5
5
ANTE ROOM - ELEV A
06.02 06.03 08.01 09.01 09.03 10.03 10.04 10.05 22.02 22.03 22.05 26.01 26.02 A B C D E F G H I J
PROVIDE WORK / ITEM
09.03
4 A7.3
NOTE: PROVIDE LOCKS ON UPPER CABINETS - HD AND NON-HD MIXING ROOMS SHALL RECEIVE UNIQUE KEY
HD MIXING ELEVATION
N.T.S.
8
09.03
4 A7.3
3
NON-HD MIXING ELEVATION
1/4" = 1'-0"
1/4" = 1'-0"
Agency Approval:
17" MIN 18" MAX
5 48" MIN
5 5
22
09.01
09.01
STAFF RESTROOM 231 ELEVATION - C
1/4" = 1'-0"
C LI
JA
18"
4' - 0"
4' - 0"
22.03
17
J
I
FOR RESTROOM SIGNAGE -REF 2 5 4 A7.4 A7.4 A7.4
09.01
STAFF RESTROOM 231 ELEVATION - B
1/4" = 1'-0"
TE
A
STAFF RESTROOM 231 ELEVATION - D
NO. C-32176
12
STAFF RESTROOM 231 ELEVATION - A
1/4" = 1'-0"
7 1/4" = 1'-0"
EN .
R
4' - 0"
06.02
22.03 F
30" X 48" CLR
ST
4' - 0"
22.02
A RCH S ED I EN A . DO T N N O
T EC E TJ
B
A
09.01
230
Architect/Engineer of Record
-1 07 - 3 1 R O F CA L I F O
Project Title:
ENLARGED FLOOR PLAN - STAFF RR 231 & PATIENT RR 233
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
2 1/4" = 1'-0"
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355 5
5
Revisions:
D
F
06.02
B
C
A
09.01
4' - 0"
4' - 0"
4' - 0"
4' - 0"
I
22.02
22.03
PATIENT RESTROOM
60" MIN
06.02 A
209
17" MIN 18" MAX
22.02 J
09.01
09.01
PATIENT RESTROOM 209 ELEVATION - D
21 1/4" = 1'-0"
PATIENT RESTROOM 209 ELEVATION - C
16 1/4" = 1'-0"
PATIENT RESTROOM 209 ELEVATION - B
60" CLR DIA 21 /A4.1
Project #: CA13500.90
1/4" = 1'-0"
PATIENT RESTROOM 209 ELEVATION - A
6 1/4" = 1'-0"
12/30/15
Drawn:
FR
Checked: JD
Sheet Title:
48" MIN
ENLARGED PLANS & INTERIOR ELEVATIONS
FOR RESTROOM SIGNAGE -REF 2 5 4 A7.4 A7.4 A7.4
11
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
11 /A4.1
Date: 09.01
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
30" x 48" CLR
16 /A4.1
G
06.02
6 /A4.1
06.02
18"
E
1 2 3 4 5
ENLARGED FLOOR PLAN PATIENT RR 209
1 1/4" = 1'-0"
A4.1
IA
22 /A4.1
06.02
22.02
STAFF RESTROOM
7
C
06.02
E
S
06.02
60" CLR DIA
N
G
60" MIN
7 /A4.1
12 /A4.1 17 /A4.1
D
5
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
KEYNOTE LEGEND
PL2 NUMBER
23
18
NOT USED
N.T.S.
3' - 0" CDS 230
3' - 2" OPEN
3' - 0" CDS 230
13
15
13
A7.3
A7.3
A7.3
14
15
A7.3
A7.3
PL2
PL1
PL1
PL2
PL1
15
09.01
3' - 6"
5
3' - 6"
42"
PL2
30"
42"
NOT USED
6' - 4" TYP
6' - 4" TYP
PL2
2' - 6"
09.01
PL2
6' - 4" TYP
PL1
06.02 06.04 09.01 F G H
PROVIDE WORK / ITEM FIBERGLASS REINFORCED PLASTIC PANEL (FRP) GROMMET 4" RESILIENT WALL BASE (REF FINISH SCHEDULE) SOAP DISPENSER (11/A7.4) SANITIZER DISPENSER (11/A7.4) PAPER TOWEL DISPENSER (11/A7.4)
09.01
A7.3
13
NURSE STATION 239 ELEVATION - D
N.T.S.
8
RECEPTION 223 ELEVATION - F
1/4" = 1'-0"
RECEPTION 223 ELEVATION - A
1/4" = 1'-0"
3 1/4" = 1'-0"
5 2' - 10" CDS 302 8 A7.3 PL1
PL2 5 11 /A4.2
2' - 6"
L
09.01
09.01
5
NOT USED
22
17
HD STORAGE 249
12
NURSE STATION 239 ELEVATION - C
1/4" = 1'-0"
N.T.S.
3' - 6" OPEN
1' - 6" CDS 230
3' - 6" OPEN
15 A7.3
13 A7.3
15 A7.3
8
8
A7.3
A7.3
A7.3
7
1/4" = 1'-0"
30" X 42" CLR
13 /A4.2
1/4" = 1'-0" R
5
3' - 0" 2' - 0" CDS 302 CDS 300
8
30" X 42" CLR
15 A7.3
13 A7.3
RECEPTION 223 ELEVATION - E
5 3' - 0" CDS 302
30" X 42" CLR
1' - 6" 2' - 1" CDS 230 OPEN
1' - 6" CDS 301
2' - 6" CDS 302
8 A7.3
8 A7.3
12 /A4.2
09.01
10 /A4.2
2' - 7 3/4" OPEN WHERE OCCURS -REF PLAN
NURSE STATION 239
15 /A4.2
PL2
3' - 6"
PL2
3' - 6"
3' - 6"
I
6' - 4" TYP
H
PL2
6' - 4" TYP
B
PL2
A7.3
14 /A4.2
SS1
2' - 3"
PL2
15
3' - 2"
7' - 5"
2' - 0"
06.02
30" X 42" CLR
P
09.01
NOT USED
3' - 0" CDS 155
3' - 0" OPEN
1
9
4
A7.3
A7.3
A7.3
21
2' - 6" PL2
7' - 4"
2' - 10"
2' - 10"
6' - 4"
3' - 6"
T
06.04
2' - 10"
G
A7.3 7' - 4"
H
3' - 0"
F
15
2' - 0"
1' - 6"
ADJUSTABLE SHELVING
09.01 2' - 6" 2' - 6" CDS 222 CDS 222
2' - 0" CDS 211
4 A7.3
NOTE: PROVIDE LOCKS ON UPPER CABINETS
NURSE STATION 239 ELEVATION - B
16
CBC AREA ELEVATION
6
RECEPTION 223 ELEVATION - D
1/4" = 1'-0"
1/4" = 1'-0"
N.T.S.
11
4 A7.3
5 EQ
2' - 0" CDS 302
ENLARGED NURSE STATION PLAN
1/4" = 1'-0"
EQ
2 1/4" = 1'-0"
Agency Approval:
3' - 0" CDS 302
8 A7.3
8 A7.3
C
S
LI
JA
NO. C-32176
A
TE
NOT USED
20
A7.3
15
NURSE STATION 239 ELEVATION - F
NOTE: PROVIDE LOCKS ON UPPER CABINETS
NURSE STATION 239 ELEVATION - A
1/4" = 1'-0"
N.T.S.
10
06.04
5
RECEPTION 223 ELEVATION - C
1/4" = 1'-0"
R
1/4" = 1'-0" RECEPTION 223
5 /A4.2 30"X48" 30"X48" CLR 4 /A4.2 CLR
30"X48" CLR
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355 Revisions: 1 2 3 4 5
2' - 7"
2' - 6"
9 /A4.2
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
30"X48" CLR
2' - 7"
5
4' - 7"
2' - 6"
PL2
PL2
4' - 1" OPEN
1' - 6" CDS 230
15 A7.3
13 A7.3
19 N.T.S.
NURSE STATION 239 ELEVATION - E
1/4" = 1'-0"
RECEPTION 223 ELEVATION - G
9 1/4" = 1'-0"
12 A7.3
1' - 6" 2' - 8" 1' - 6" 2' - 7 3/4" CDS 230 OPEN CDS 230 OPEN 12 A7.3
15 A7.3
3 /A4.2
Project #: CA13500.90 Date:
12 A7.3
15 A7.3
AP
Checked: JD
ENLARGED PLANS & INTERIOR ELEVATIONS
4' - 6 1/4" CDS 230 12 A7.3
RECEPTION 223 ELEVATION - B
12/30/15
Drawn:
Sheet Title:
PL2
09.01
2' - 3 3/4" 3' - 0" OPEN CDS 230
09.01
14
5 PL2
PL2
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
PL1
5
15 A7.3
NOT USED
PL2
3' - 6"
PL1
R
PL2
6' - 4" TYP
PL1
PL2
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
5' - 0" MIN PULL UP AREA
13' - 0"
3' - 6"
PL2
2' - 6"
PL2
6' - 4" TYP
PL2
2' - 7"
3' - 6"
6' - 4" TYP
3' - 3" PL1
4 1/4" = 1'-0"
ENLARGED RECEPTION PLAN
1 1/4" = 1'-0"
A4.2
7
-1 07 - 3 1 R O F CA L I F O
Project Title:
4 A7.3
8 /A4.2
A7.3
1 A7.3
3' - 0" CDS 222
13' - 0"
15
09.01
09.01
6 /A4.2
13
3' - 0" CDS 155
09.01
7 /A4.2
3' - 4" OPEN
2' - 7"
1' - 6" CDS 230
EN .
IA
1' - 9"
06.04
N
4' - 10"
2' - 10"
PL2
7' - 4"
06.04 6' - 4" TYP
H
A RCH S ED I EN A . DO T N N O
R
P
A7.3
ST
2' - 7"
3' - 6"
6' - 4" TYP
PL2
G
15
Architect/Engineer of Record
T EC E TJ
PL1
5
3' - 6"
F
PL2
3' - 0"
PL2
PL2
2' - 6"
1' - 6"
5
5
5 FILLER PANEL
6' - 4"
3' - 0" CDS 302
2' - 9" CDS 302
2' - 9" CDS 302
2' - 9" CDS 302
8 A7.3
8 A7.3
8 A7.3
8 A7.3
EQ EQ EQ EQ EQ EQ
FILLER PANEL
3' - 0" CDS 302
3' - 0" CDS 301
2' - 8 1/4" CDS 302
8 A7.3
8 A7.3
8 A7.3
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
25
FILLER PANEL
20
STAFF BREAK ROOM 230 ELEVATION - A
N.T.S.
NOT USED
3' - 0" CDS 155
2' - 9" CDS 222
2' - 9" CDS 222
2' - 9" CDS 222
1 A7.3
4 A7.3
4 A7.3
4 A7.3
15
A7.3
A7.3
7' - 4"
2' - 0"
PROVIDE CABINET LOCK GROMMET 4" RESILIENT WALL BASE (REF FINISH SCHEDULE) INTEGRAL COVE BASE (19/A7.1) 5 GLOVES BOX OFCI SHARPS BOX OFCI EYE WASH (REF PLUMBING) SOAP DISPENSER (11/A7.4) SANITIZER DISPENSER (11/A7.4) PAPER TOWEL DISPENSER (11/A7.4)
1' - 6" 3' - 0" 1' - 6" FILLER PANEL CDS 211 CDS 222 CDS 211
9 A7.3
HALLWAY 219 ELEVATION - A
PROVIDE WORK / ITEM
4 A7.3
10
4 A7.3
4 A7.3
5
SOIL 202 ELEVATION - B
1/4" = 1'-0"
1/4" = 1'-0"
5
2' - 0" 3' - 0" CDS 302 CDS 302 8
I 1' - 6" OPEN
5
8
SS1 E
N.T.S.
1/4" = 1'-0"
C
06.03 06.04 09.01 09.03 10.04 10.05 22.04 F G H
7' - 4"
2' - 6"
1' - 6"
06.03
2' - 10 1/4"1' - 11 3/4" 2' - 6"
PL2
09.01
NOT USED
H
G
2' - 10"
PL1
06.04
2' - 0"
PL2
F 7' - 0"
1' - 8" 1' - 8" 1' - 8"
NUMBER
2' - 6" 2' - 6" CDS 302 CDS 302
FILLER PANEL
8 A7.3
(E) STOREFRONT
EQ
FILLER PANEL
EQ
EQ (E) STOREFRONT
20
8 A7.3
A7.1
2' - 6"
7' - 2"
4 A7.3
4 A7.3
PL2
A7.3
19
INFUSION ELEVATION - TYP
1/4" = 1'-0"
14 1/4" = 1'-0"
5
1 A7.3
H
SS1
H
G
S
1' - 7 1/4" OPEN
A7.3
A7.3
5
8 A7.3
3' - 7" CDS 302
3' - 7" CDS 302
8 A7.3
8 A7.3
8 A7.3
06.03
F
13
8
INFUSION 7 - GLASS ELEVATION A
4 A7.3
4 A7.3
CLEAN 201 ELEVATION - C
1/4" = 1'-0"
5
8
8
A7.3
A7.3
PL2
06.03 10.05
PL1
G
10.04
2' - 10"
2' - 10"
H
1 A7.3
3' - 3" 1' - 5" FILLER PANEL CDS 222 CDS 211
3 1/4" = 1'-0"
Agency Approval:
5
2' - 0"
G
3' - 3" CDS 155
ANOD AL FRAMING W/ CLEAR LAMINATED GLAZING
1/4" = 1'-0"
2' - 6"
2' - 6" 2' - 0"
3' - 7" CDS 302
F
FILLER PANEL
TYP
5
F
H PL2
Architect/Engineer of Record
NO. C-32176
NOTE: PROVIDE LOCKS ON UPPER CABINETS
CLEAN LINEN AREA ELEVATION
22
3' - 7" CDS 222
3' - 7" CDS 222
4 A7.3
4 A7.3
4 A7.3
4 A7.3
MD WORKROOM 225 ELEVATION - A
2' - 9" CDS 300
8 A7.3
8 A7.3
MA 213 ELEVATION - A
1/4" = 1'-0"
5
W
F
3' - 0" CDS 302
2' - 5 1/4" CDS 302
1' - 2 1/2" CDS 301
8 A7.3
8 A7.3
8 A7.3
1 A7.3
2' - 6" CDS 222
F
09.03
4 A7.3
21 1/4" = 1'-0"
NOT USED
16 N.T.S.
7
NOT USED
2
1' - 1 3/4" CDS 301
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355 Revisions:
(E) STOREFRONT
8 A7.3
8 A7.3
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
N.T.S.
1/4" = 1'-0"
1 2 3 4 5
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
H
H
06.03
3' - 0" CDS 155
2' - 5 1/4" CDS 222
1' - 2 1/2" CDS 211
1 A7.3
4 A7.3
4 A7.3
HALLWAY 207 ELEVATION - B
SS1
22.04 G SS1
1' - 2 1/4" CDS 211
3' - 0" CDS 155 4 A7.3
11 1/4" = 1'-0"
1 A7.3
1' - 1 3/4" CDS 211
FILLER PANEL
4 A7.3
4 A7.3
SOIL 202 ELEVATION - C
1' - 6" 3' - 6" CDS 211 CDS 222
6 1/4" = 1'-0"
4 A7.3
3' - 6" CDS 222
Project #: CA13500.90 Date:
1 1/4" = 1'-0"
FR
Checked: JD
INTERIOR ELEVATIONS
4 A7.3
CLEAN 201 ELEVATION - A
12/30/15
Drawn:
Sheet Title:
FILLER PANEL
-1 07 - 3 1 R O F CA L I F O
Project Title:
F
G
STAFF BREAK ROOM 230 ELEVATION - B
A7.3
5
INFUSION 7 ELEVATION
8 A7.3
2' - 10" 3' - 0" CDS 155
A7.3
2' - 2 1/4" 3' - 0" CDS 302 CDS 302
F H
5
1' - 6"
1' - 6"
12
2
1/4" = 1'-0"
ADJUSTABLE SHELF
G
2' - 6" 2' - 6" CDS 155 CDS 272
13 A7.3
2' - 0"
2' - 0"
2' - 9" CDS 302
17
9 A7.3
2' - 10"
7' - 4"
2' - 6"
1/4" = 1'-0"
09.01
09.03
2' - 10"
1 A7.3
3' - 7" CDS 222
2' - 10 1/4"
4 A7.3
3' - 7" CDS 222
TE
A
3' - 0" CDS 155
EN .
R
ST
1' - 4" CDS 211
3' - 0" 1' - 6" FILLER PANEL OPEN CDS 230
A RCH S ED I EN A . DO T N N O
T EC E TJ
7' - 4"
3' - 7" CDS 302
.
2' - 2" OPEN
1/4" = 1'-0"
3' - 6"
8
1' - 7 1/2" CDS 100
MA 213 ELEVATION - B
7' - 4"
8
18
CONFERENCE ROOM 226 ELEVATION - A
1' - 6"
3' - 0" CDS 302
7' - 6" CDS 230 5 A7.3
N.T.S. 1' - 4" CDS 301
8 A7.3
A4.3
IA
4 A7.3
8 A7.3
F
2' - 7"
4 A7.3
8 A7.3
1' - 6"
2' - 0"
3' - 0" CDS 155
3' - 0" CDS 302
7' - 4"
23
2' - 7" CDS 222
3' - 3" CDS 302
A7.1
2' - 7"
NOT USED
1' - 3" CDS 211
3' - 3" CDS 302
20
2' - 10"
7' - 4"
G
FILLER PANEL
4' - 0"
2' - 0" 2' - 6 1/4"
8 A7.3
3' - 7 1/4"
2' - 10"
8 A7.3
7' - 2"
8 A7.3
3' - 7 1/4"
5
1/4" = 1'-0"
1' - 6"
3' - 0" CDS 302
2' - 6"
2' - 7" CDS 302
4
SOIL 202 ELEVATION - A
1/4" = 1'-0" 11' - 7"
1' - 3" CDS 301
9
INFUSION 7 - GLASS ELEVATION B
7
1/4" = 1'-0"
HALLWAY 219 ELEVATION - B
N
24
9 A7.3
4 A7.3
C
NUTRIENT BAR ELEVATION
09.01
ANOD AL FRAMING W/ CLEAR LAMINATED GLAZING
S
7 A7.3
2' - 7" 2' - 7" CDS 222 CDS 222
LI
09.03
1
FILLER PANEL
JA
09.03
2' - 6" 2' - 6" CDS 222 CDS 222
FILLER PANEL
7' - 4"
7' - 0" CDS 110
2' - 6"
PL1
2' - 0"
3' - 0" CDS 155
PL2
SS1
2' - 10"
2' - 0" OPEN
06.03
PL1
K
2' - 0"
U
G
2' - 6"
H
E
F
2' - 10"
1' - 8"
06.04
3' - 2"
7' - 4"
2' - 6"
5
MANUFACTURER: WILSONART CONTRACT TYPE: HW 107 COLOR: CASUAL LINEN 4944 - 38 INSTALLATION: COUNTERTOPS
SV1
5
MANUFACTURER: ARMSTRONG INTEGRAL COVE STYLE: MEDINTONE COLOR: H8300 COOL WHITE HEIGHT: 6" HEATWELD: W0738 GRAY SMOKE SOLID WELD FIRE CLASS: CLASS 1 SMOKE EVOLUTION: 450 OR LESS VOC: CA 01350 COMPLIANT
MANUFACTURER: MAHARAM STYLE: BEAD COLOR: 006 CAFÉ TRACK DIM: REF FLOOR PLAN FIRE CLASS/TEST: ASTM E 84 FLAME SPREAD: 5 SMOKE DENSITY: 50 VOC: CERTIFIED LOW EMISSION
MANUFACTURER: BURKE TYPE: STRAIGHT RUBBER BASE, TS COLOR: 674 CARMINE GRAY HEIGHT: 4" NOTE: TYP AT CARPET FLOORING LOCATIONS, U.N.O. FIRE CLASS: N/A FLAME SPREAD: N/A SMOKE DENSITY: N/A VOC: CERTIFIED LOW EMISSIONS
MANUFACTURER: WILSONART CONTRACT TYPE: HW 107 COLOR: MONTICELLO MAPLE 7925 - 38 INSTALLATION: COUNTERTOPS 5
RESILIENT SHEET FLOORING
MANUFACTURER: BURKE TYPE: COVED RUBBER BASE, TS COLOR: 674 CARMINE GRAY HEIGHT: 4" NOTE: TYPICAL AT RESILIENT FLOORING LOCATIONS, U.N.O. FIRE CLASS: N/A FLAME SPREAD: N/A SMOKE DENSITY: N/A VOC: CERTIFIED LOW EMISSIONS
B1
WALL PROTECTION
MANUFACTURER: ARMSTRONG STYLE: MEDINTONE COLOR: H8300 COOL WHITE HEATWELD: WO738 GRAY SMOKE SOLID WELD FIRE CLASS: CLASS 1 SMOKE EVOLUTION: 450 OR LESS VOC: CA 01350 COMPLIANT
WP1
MANUFACTURER: CONSTRUCTION SPECIALTIES (C/S) MODEL: ACROVYN 4000 MODEL #: SM-20N TYPE: PVC FREE SURFACE-MOUNTED CORNER GUARD COLOR: 920 ALMOND COLOR #: 933 WIDTH: 3" FINISH: PEBLETTE HEIGHT: PARTIAL (48" MIN A.F.F.)
ROLLER WINDOW SHADES WS1
5
MANUFACTURER: MECHOSHADE STYLE: THERMOVEIL 1500 SERIES OPENESS: 3% COLORS: TO BE SELECTED FROM MANUFACTURER'S STANDARD RANGE OF COLORS LOCATION: ALL NON-EXAM AND NON-PROCEDURE RMS 5
MANUFACTURER: MECHOSHADE STYLE: MIDNITE BLACKOUT 0200 SERIES OPENESS: 0% COLORS: TO BE SELECTED FROM MANUFACTURER'S STANDARD RANGE OF COLORS LOCATION: ALL EXAM AND PROCEDURE RMS
SOLID SURFACING SS1
FIBERGLASS REINFORCED PANEL
MANUFACTURER: WILSONART CONTRACT COLOR: COCONUT OIL 9100 GS PRODUCT TYPE: 051, 1/2" THICK
TRANSITION
MANUFACTURER: MARLITE COLOR: GENOA 5413 - G1212 INSTALLATION: RESTROOM WALLS UP TO 48" A.F.F. (TYP)
T1
MANUFACTURER: BURKE TYPE: CARPET TO RESILIENT FLOOR TRANSITION COLOR: TBD FROM MFR'S STD COLORS
5
4
FINISH MATERIALS
N.T.S.
INITIAL INSERTION POINT GENERAL PATTERN NOTES 1. ALL EXAM ROOMS/PROCEDURE ROOMS TYPICAL FLOOR PATTERN. 2. INITIAL INSERTION POINT AT OUTSIDE CORNER OF DOOR FRAME, CLOSEST TO WALL (REGARDLESS OF DOOR SWING) 5
3. TILE PATTERN/COLOR SPREAD INTO ROOM. 4. TILE PATTERN/COLOR SPEAD TO CONTINUE TO OPPOSITE WALL REGARDLESS OF ROOM SIZE.
5
5
5
5
5
VCT1 VCT1 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1 VCT1 VCT1 C1 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1 VCT1 C1 C1 C1 C1 C1 C1 C1 VCT1 VCT1 VCT1 VCT1 VCT1,2,3 VCT1 SV1 SV1 SV1 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1,2,3 VCT1 SV1 SV1 VCT1,2,3
CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 B1 CB1 B1,CB1 B1,CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB2 CB2 CB2 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB1 CB2 CB2 CB1
CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 CC1 -
P1 P1 P1 P2 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P2 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1
EG EG EG EG EG EG EG EG FRP1,GB EG EG EG 5 EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG FRP1,GB FRP2 EG EG EG FRP1,GB FRP2 FRP2 FRP2 EG EG EG EG EG EG EG EG EG EG FRP2 FRP2 EG
EG EG EG EG EG EG EG EG FRP1,GB EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG FRP1, GB FRP2 EG EG EG FRP1, GB FRP2 FRP2 FRP2 EG EG EG EG EG EG EG EG EG EG FRP2 FRP2 EG
P1 P1 P1 P1 P2 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1
EG EG EG EG EG EG EG EG FRP1,GB EG EG EG EG EG EG EG EG EG 5 EG EG EG EG EG EG EG EG EG EG FRP1,GB FRP2 EG EG 5 EG FRP1,GB FRP2 FRP2 FRP2 EG EG EG EG EG EG EG EG EG EG FRP2 FRP2 EG
P1 P1 P1 P1 P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1
5
P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1
P1 P1 P2 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1
P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P1
FINISH
P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P2 P1 P2 P1 P1 P1 P1 P1 P1 P1
MATERIAL
WEST
EG EG EG EG EG EG EG EG FRP1,GB EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG 5 EG FRP1,GB FRP2 EG EG EG FRP1,GB FRP2 FRP2 FRP2 EG EG EG EG EG EG EG EG 5 EG EG FRP2 FRP2 EG
ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 GB ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1,GB ACT1 ACT1 ACT1 ACT1 ACT1 GB ACT1 ACT1 ACT1 ACT1 GB ACT2 ACT2 ACT2 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT1 ACT2 ACT2 ACT1
COLOR
PL2
WALL BASE
CLEAN SOILED PROCEDURE 1 PROCEDURE 2 EXAM 6 EXAM 5 HALLWAY SUPPLY STORAGE PATIENT RESTROOM EQUIPMENT ROOM RESEARCH OFFICE EXAM 7 MA MA EXAM 4 EXAM 3 EXAM 2 EXAM 1 HALLWAY CONSULT EQUIPMENT ROOM OFFICE RECEPTION SURGERY SCHEDULER MD WORKROOM CONFERENCE ROOM WAITING DIRECTOR OFFICE STAFF RESTROOM SOILED UTILITY STAFF BREAK RM. IT/IDF CLOSET HALLWAY PATIENT RESTROOM ANTE ROOM NON-HD MIXING HD MIXING NURSE STATION INFUSION 1 INFUSION 2 INFUSION 3 INFUSION 4 INFUSION 5 INFUSION 6 INFUSION 7 INFUSION 8 SUPPLIES HD STORAGE NON-HD STORAGE INFUSION AREA
SOUTH
FINISH
PL1
PRIVACY CURTAIN
FF FF FF FF FF FF FF FF EG FF FF FF FF FF FF FF FF FF FF FF FF FF EG FF FF FF FF FF EG FF FF FF FF EG FF
P1 P1 P1 P1 -
FF FF FF FF FF FF FF FF FF FF FF FF FF FF
-
BCCBCTFF PACTFRP-
STRAIGHT WALL BASE SVCARPET EG COVE BASE FT CERAMIC TILE GB FACTORY FINISH QTPAINT SG ACOUSTICAL CEILING TILE VCTFIBERGLASS REINFORCED 5 PANEL
3
1
2
3
4
ROOM FINISH SCHEDULE 6
1/4" = 1'-0"
7
8
9
10
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
FINISH SCHEDULE REMARKS 1. REFER TO FINISH PLAN FOR FLOORING LOCATION & PATTERNS. 2. REFER TO INTERIOR ELEVATIONS & FINISH PLAN FOR ACCENT PAINT LOCATION. 3. ALL PAINT SHALL BE
P1
U.N.O
4. ALL CASEWORK COUNTERTOPS SHALL BE 5. ALL CASEWORK FACES SHALL BE 6. ALL WINDOWS SHALL RECEIVE
PL2
WS1
PL1
U.N.O
U.N.O
U.N.O. IN FINISH MATERIALS NOTES
GENERAL FINISH NOTES 1. ALL WALL, CEILING AND FLOOR FINISHES SHALL COMPLY WITH 2013 CBC SECTION 803, 804 AND 805. 2. ALL FINISH MATERIALS SHALL COMPLY WITH VOC LIMITS SET FORTH IN THE CALIFORNIA GREEN BUILDING STANDARD SECTION 5.504.4.1 THROUGH 5.504.4.4. 3. REFER TO SCHEDULE OF FINISHES FOR FINISH/PRODUCT INFORMATION. 4. CARDINAL DIRECTION (E.G. NORTH, EAST, SOUTH, WEST) REFERS TO PLAN DIRECTION, NOT TRUE CARDINAL DIRECTION. 5. REFER TO SPECIFICATION FOR ADDITIONAL INSTALLATION METHODS AND REQUIREMENTS. 6. INTERIOR PAINT LOCATIONS TO BE SITE VERIFIED BY ARCHITECT PRIOR TO PAINTING. 7. ACCENT PAINTS LOCATED ON PLAN ARE SUBJECT TO CHANGE PENDING OWNER APPROVAL. 8. REFER TO DOOR SCHEDULE FOR FLOORING TRANSITIONS AT DOOR. ALL OTHERS, REFER TO SPEC. SECTION 096513. 9. CONTRACTOR TO TEST EXISTING SLAB CONDITION FOR MOISTURE. PROVIDE MOISTURE MITIGATION TO ACCEPTABLE LEVELS AS REQUIRED BY FLOORING MANUFACTURES. REFER TO SCHEDULE OF FINISHES AND SPECIFICATIONS. 10. CONTRACTOR SHALL PATCH AND REPAIR FINISHES IN PUBLIC CORRIDOR AS A RESULT OF NEW WORK. 11. PROVIDE WALL PROTECTION THROUGHOUT SUITE PER FINISH MATERIALS HEREIN.
MATERIALS LEGEND ACT#
ACOUSTICAL CEILING TILE
B#
STRAIGHT WALL BASE
C#
CARPET
CB#
COVE BASE
CC#
PRIVACY CURTAIN
FRP#
FIBERGLASS REINFORCED PANEL
P#
PAINT
PL#
PLASTIC LAMINATE
WS#
ROLLER WINDOW SHADES
SV#
RESILIENT SHEET FLOORING
5
TRANSITION
VCT#
VINYL COMPOSITION TILE
WP#
WALL PROTECTION
2 N.T.S.
5
RESILIENT SHEET FLOORING EGGSHELL PAINT FINISH FLAT PAINT FINISH GYPSUM BOARD CERAMIC FLOOR TILE SEMI GLOSS VYNIL COMPOSITION TILE
NOTE: NOT ALL ABBREVIATIONS ARE USED.
T#
TYP EXAM RM / PROCEDURE RM FLOOR FINISH PLAN
5
FINISH PLAN LEGEND
Agency Approval:
SCOPE OF WORK AREA
11
C1 - CARPET
5
SV1 - RESILIENT SHEET FLOORING
C
Architect/Engineer of Record
OFFICE
RECEPTION
220
221
222
223
IT/IDF CLOSET
STAFF BREAK RM.
227
233
232
NO. C-32176
STAIRS 2
212
5
MA
MA
213
214
MECH. RM. JAN.
5
P2
PATIENT RESTROOM
NON-HD MIXING
235
237
D WP1
236
SUITE 240
211
WP1
WP1
P2
219
WP1
WP1
Project Title:
WP1
HD STORAGE 249 P2
SUITE 250
x2
WP1
x2
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
SUPPLIES 248
NON-HD STORAGE
PF
EQUIPMENT ROOM
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355
250
P2
210
PATIENT RESTROOM
WP1
P2
P2
HALLWAY
WP1
234
P2
WP1
WP1
WP1 x2
P2
INFUSION 7 246
INFUSION 8
209
SUPPLY STORAGE
WP1 HALLWAY
208
WP1 EXAM 4
EXAM 3
EXAM 2
EXAM 1
215
216
217
218
DIRECTOR STAFF OFFICE RESTROOM 229
230
INFUSION 1
231
240
P2
x2
INFUSION AREA
207
SOILED
P2
202
1 2 3 4 5
INFUSION 6 245
251
SUITE 260
EXAM 5
EXAM 6 205
CLEAN PROCEDURE 2 204
SURGERY SCHEDULER
3 A5.1
INFUSION 2
WP1
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
244
241
224
CONFERENCE ROOM
MD WORKROOM
226
TYP
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
INFUSION 5
206
201
Revisions:
247
WP1
SOILED UTILITY
-1 07 - 3 1 R O F CA L I F O
238
ELEVATOR
WP1
HALLWAY
EN .
ANTE ROOM HD MIXING 5
RESEARCH OFFICE
E
TE
A
EXAM 7
R
VCT3 - VINYL COMPOSITION TILE
ST
5
WAITING
INFUSION 4 243
225
Project #: CA13500.90
F INFUSION 3
NURSE STATION
242
239
Date:
12/30/15
Drawn:
FR
Checked: JD
Sheet Title:
FINISH FLOOR PLAN & INTERIOR FINISHES
PROCEDURE 1 203
FINISH FLOOR PLAN
1 3/32" = 1'-0"
A5.1
IA
EQUIPMENT ROOM
7
CONSULT
N
STAIRS 1
S
LI
VCT2 - VINYL COMPOSITION TILE
A RCH S ED I EN A . DO T N N O
T EC E TJ
C
VCT1 - VINYL COMPOSITION TILE
JA
FRP1
201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251
PLASTIC LAMINATE BROADLOOM CARPET MANUFACTURER: SHAW STYLE: TIMBER COLOR: IROKO SIZE: BROADLOOM NOTE: INSTALL QUARTER TURN FIRE CLASS: CLASS I SMOKE DENSITY: ASTM E 662 LESS THAN 450 VOC: CA 01350 COMPLIANT
WS2
CC1
MANUFACTURER: MANNINGTON STYLE: ESSENTIALS COLOR: FLAX 143 SIZE: 12" X 12" INSTALLATION: ACCENT
NAME
EAST
COLOR
VCT3
MANUFACTURER: SHERWIN WILLIAMS COLOR: COLLONADE GRAY SW 7641 FINISH: EGGSHELL INSTALLATION: ACCENT WALL
NUMBER
NORTH
CEILING
FINISH
P2
MANUFACTURER: SHERWIN WILLIAMS COLOR: GREEK VILLA SN 7551 FINISH: EGGSHELL INSTALLATION: MAIN WALL PAINT
WALLS
COLOR
P1
MANUFACTURER: MANNINGTON STYLE: ESSENTIALS COLOR: ALMONDINE 33 SIZE: 12" X 12" INSTALLATION: ACCENT
BASE
FINISH
VCT2
FLOOR
COLOR
CB2
MANUFACTURER: MANNINGTON STYLE: ESSENTIALS COLOR: COOL WHITE 141 SIZE: 12" X 12" INSTALLATION: FIELD COLOR
FINISH
PAINT
COVE BASE CB1
VCT1
COLOR
MANUFACTURER: MARLITE TYPE: STANDARD FRP, SMOOTH SURFACE COLOR: S/2/S WHITE INSTALLATION: FULL-HEIGHT OF WALLS
5
MANUFACTURER: UNITED STATES GYPSUM (USG) STYLE: CLEAN ROOM CLASS 100 PANELS (UNPERFORATED) COLOR: WHITE EDGE: SQUARE TEXTURE: FINE SUSPENSION SYSTEM: DONN BRAND CE, HEAVY DUTY
CARPET C1
FRP2
PRIVACY CURTAIN
ACT2
MANUFACTURER: UNITED STATES GYPSUM (USG) STYLE: MARS CLIMA PLUS COLOR: FLAT WHITE EDGE: SQUARE TEXTURE: FINE SUSPENSION SYSTEM: DONN DX / DXL, HEAVY DUTY
MATERIAL/COLOR
ACT1
FINISH ABBREVIATIONS
ROOM FINISH SCHEDULE
VINYL COMPOSITION TILE
5
MATERIAL/COLOR
ACOUSTICAL CEILING TILE
DOOR ABBREVIATIONS DOOR SCHEDULE
MATERIAL
FINISH
MATERIAL
FINISH
PANIC HARDWARE
TYPE
HARDWARE GROUP
GLAZING TYPE
HEAD
JAMB
REMARKS
THRESHOLD
GLAZING TYPES
FINISHES
CL
FF
CLEAR LAMINATED GLASS
NR NR NR NR NR NR
SCWD SCWD SCWD SCWD SCWD SCWD
PL PL PL PL PL PL
2 1 1 1 1 3
SCWD SCWD SCWD SCWD SCWD SCWD SCWD SCWD (E) SCWD SCWD SCWD SCWD SCWD SCWD SCWD SCWD SCWD SCWD SCWD SCWD SCWD (E) SCWD SCWD SCWD SCWD SCWD SCWD SCWD AL SCWD SCWD SCWD
PL PL PL PL PL PL PL PL (E) FF PL PL PL PL PL PL PL FF PL PL PL PL (E) FF PL FF PL PL PL PL ANOD PL PL PL
1 1 2 1 1 1 1 1 (E) 2 1 1 2 2 1 2 1 2 1 1 1 (E) 2 1 1 1 1 1 4 1 2 2
5
NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR NR
5
HM HM HM HM HM HM HM HM AL HM HM HM HM HM HM HM AL HM HM HM HM (E) AL HM AL HM HM HM HM AL HM HM HM
PT PT PT PT PT PT PT PT ANOD PT PT PT PT PT PT PT ANOD PT PT PT PT (E) ANOD PT ANOD PT PT PT PT ANOD PT PT PT
No No No No No No
2 1 1 1 1 3
CL -
No No No No No No No No Yes No No No No No No No Yes No No No No No No Yes No No No No No No No No
4 7 8 1 1 1 1 1 10 9 1 7 8 8 8 2 10 8 4 4 2 10 9 10 2 5 2 2
CL (E) CL CL CL CL CL CL CL
5
5
5
5
5
5 5
5
5
1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 -
1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 -
1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 SIM 1/A6.1 SIM 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 SIM 1/A6.1 SIM 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 (E) (E) 1/A6.1 1/A6.1 1/A6.1 SIM 1/A6.1 SIM 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1 1/A6.1
2/A6.1 2/A6.1 2/A6.1 2/A6.1 2/A6.1 - 5 2/A6.1 2/A6.1 2/A6.1 2/A6.1 2/A6.1 2/A6.1 2/A6.1 2/A6.1 1/A6.1 SIM 2/A6.1 2/A6.1 2/A6.1 2/A6.1 2/A6.1 2/A6.1 2/A6.1 1/A6.1 SIM 2/A6.1 2/A6.1 2/A6.1 2/A6.1 (E) 2/A6.1 1/A6.1 SIM 2/A6.1 2/A6.1 1/A6.1 1/A6.1 1/A6.1 2/A6.1 2/A6.1
1 1 1 1 1 1
5 LBS 5 LBS 15 LBS
6. GLAZING IN FIRE RATED DOOR TO HAVE U.L. APPROVED ASSEMBLIES. 7. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INTERIOR WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT (CBC SECTION 1008). 2 8. ROOM IDENTIFICATION SIGNAGE PLACEMENT, REF A7.4
DOOR REMARKS REMARK
1.
ROOM IDENTIFICATION SIGNAGE
7 A7.4
2.
EXIT ROUTE / EXIT
6 A7.4
3.
UNISEX RESTROOM DOOR SIGNAGE
5 A7.4
4.
PREPARE (E) DOOR AND FRAME FOR ACCESS CONTROL HARDWARE BY TENANT'S SECURITY VENDOR. REPLACE ONE (1) HINGE W/ HINGE NOTED IN DOOR HARDWARE GROUP 10. 5
6.
PREPARE DOOR AND FRAME FOR ACCESS CONTROL HARDWARE BY TENANT'S SECURITY VENDOR.
5
652 626 626 626 GRY
IVES SCHLAGE SCHLAGE IVES IVES
DESCRIPTION
CATALOG NUMBER
FINISH
MFR
POCKET DOOR KIT POCKET DOOR LOCK MORTISE CYLINDER FSIC CORE
9850 9100ADAL-3ST 26-064 / X CAM WHERE REQ'D 23-030 EV C123 (0 BITTED)
AL 626 626 626
HAGER ACCURATE SCHLAGE SCHLAGE
DESCRIPTION
CATALOG NUMBER
FINISH
MFR
HINGE PRIVACY LOCK SURFACE CLOSER KICK PLATE MOP PLATE FLOOR STOP THRESHOLD SILENCER
5BB1 4.5 X 4.5 ND40S RHO 4041 DEL 8400 10" X 2" LDW B-CS 8400 4" X 1" LDW B-CS FS436 / FS438 AS REQ'D 546A MSLA-10 OR AS REQ'D SR64
652 626 689 630 630 626 AL GRY
IVES SCHLAGE LCN IVES IVES IVE ZERO INT'L IVES
DESCRIPTION
CATALOG NUMBER
FINISH
MFR
2 EA 1 EA 1 EA 1 EA 1 EA 1 EA 3 EA 1 EA 1 EA TYPE 6: QTY
HINGE ELECTRIC HINGE EU MORTISE LOCK FSIC CORE FLOOR STOP THRESHOLD SILENCER DOOR CONTACT POWER SUPPLY
5BB1 4.5 X 4.5 5BB1 4.5 X 4.5 TW8 L9092TEU 06A RX 23-030 EV C123 (0 BITTED) FS436 / FS438 AS REQ'D 546A MSLA-10 OR AS REQ'D SR64 7764 PS902
652 652 626 626 626 AL GRY 628 LGR
IVES IVES SCHLAGE SCHLAGE IVES ZERO IVES SCHLAGE SCHLAGE
DESCRIPTION
CATALOG NUMBER
FINISH
MFR
1
WIRE TRANSFER HINGE
4.5 X 4.5 PB81 ETW-4
652
PBB INC
626
SCHLAGE
SET EA EA EA
5"
EA EA EA EA EA EA EA EA
EA
DESCRIPTION
CATALOG NUMBER
FINISH
MFR
HINGE STOREROOM LOCK SURFACE CLOSER KICK PLATE FLOOR STOP SILENCER
5BB1 4.5 X 4.5 ND80JD RHO 4040XP 8400 10" X 2" FS436 SR64
652 626 689 630 626 GRY
IVES SCHLAGE LCN IVES IVES IVES
DESCRIPTION
CATALOG NUMBER
FINISH
MFR
HINGE ENTRANCE / OFFICE LOCK FSIC CORE FLOOR STOP SILENCER
5BB1 4.5 X 4.5 ND50JD RHO 23-030 EV C123 (0 BITTED) FS436 SR64
652 626 626 626 GRY
IVES SCHLAGE SCHLAGE IVES IVES
DESCRIPTION
CATALOG NUMBER
FINISH
MFR
HINGE ENTRANCE LOCK FSIC CORE FLOOR STOP SILENCER
5BB1 4.5 X 4.5 ND53JD RHO 23-030 EV C123 (0 BITTED) FS436 SR64
652 626 626 626 GRY
IVES SCHLAGE SCHLAGE IVES IVES
TYPE 10: QTY
DESCRIPTION
CATALOG NUMBER
FINISH
MFR
1 3 1 1 1
WIRE TRANSFER HINGE HINGE LOCKSET DOOR CLOSER FLOOR STOP
4.5 X 4.5 PB81 ETW-4 4.5 X 4.5 PBB81 L-9080 EU 06 8501 1211
652 652 626 689 626
PBB INC PBB INC SCHLAGE NORTON TRIMCO
EA EA EA EA EA EA
EA EA EA EA EA
TYPE 9: QTY 3 1 1 1 3
5" .
5BB1 4.5 X 4.5 ND70JD RHO 23-030 EV C123 (0 BITTED) FS436 SR64
3 1 1 1 3
2" GLAZING PER SCHED
HINGE CLASSROOM LOCK FSIC CORE FLOOR STOP SILENCER
EA EA EA EA EA
TYPE 8: QTY
2" VARIES 2" PER SCHED.
REF SCHED 5"
MFR
3 1 1 1 1 3
4 A7.4
CONTRACTOR MAY RE-USE (E) SUITE ENTRY DOOR AND FRAME TO BE DEMOLISHED UNDER DEMOLITION CONTRACT.
6"4"
FINISH
TYPE 7: QTY
5.
REF SCHED
CATALOG NUMBER
1 EA LOCKSET L-9080 EU 06 * ALL OTHER (E) DOOR HARDWARE SHALL REMAIN
DETAIL
5 REF SCHED
DESCRIPTION
TYPE 5: QTY
FRAME TYPES
REF SCHED
IVES SCHLAGE IVES IVES
3 1 1 1 1 1 1 3
5. ALL RATED ASSEMBLIES SHALL BE PROVIDED WITH APPROVED GASKETING, AND BE SELF-CLOSING WITH POSITIVE LATCH, PER CBC SECTION 1008.1.8-1008.1.9.
DOOR TYPES
652 626 626 GRY
TYPE 4: QTY
4. "LABEL" SHALL MEAN "ASSEMBLY" AS DEFINED IN SECTION 715.4.5-4.5.4 CALIFORNIA BUILDING CODE.
1 1 1
5BB1 4.5 X 4.5 ND10S RHO FS436 SR64
1 1 1 1
AUTHORITY HAVING JURISDICTION MAY APPROVE ADJUSTMENT UP TO 15 LBS. 1 3. FOR REQUIRED DOOR CLEARANCES REF A7.4
5
HINGE PASSAGE SET FLOOR STOP SILENCER
EA EA EA EA
TYPE 3: QTY
2. MAXIMUM EFFORT TO OPERATE DOORS:
NUMBER
MFR
3 1 1 1 3
1. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INTERIOR WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT (CBC SECTION 1008).
INTERIOR: EXTERIOR: FIRE RATED:
FINISH
TYPE 2: QTY
GENERAL DOOR NOTES
1, 3 1 1 1 1 1 1 1 1, 2, 4 1, 2, 6 1 1 1 1 1 1, 2 1, 2, 6 1 1, 3 1 1 1 1, 2, 6 1, 2, 4 1, 3 1, 2, 6 1 1
CATALOG NUMBER
GLAZING PER SCHED .
EA EA EA EA EA
EA EA EA EA EA
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
10"
1
2
3
4
A
SOLID PANEL -REF PLAN FOR SWING DIRECTION
SOLID PANEL WITH VISION GLASS
POCKET DOOR -REF HARDWARE SETS FOR FRAME
ALUMINUM SLIDING DOOR WESTERN INTEGRATED ALUMAGLIDE SLIDING DOOR
FRAME ONLY
DOOR SCHEDULE AND NOTES
3 N.T.S.
Agency Approval:
DOOR FRAME BEYOND TOP OF CONCRETE SLAB
RESILIENT FLOORING WHERE OCCURS
Architect/Engineer of Record
LI
TRANSITION
A RCH S ED I EN A . DO T N N O
T EC E TJ
DOOR
EN .
A
Project Title:
NOT USED
11
NOT USED
N.T.S.
9
NOT USED
N.T.S.
7
NOT USED
N.T.S.
5
DOOR SILL
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
2 6" = 1'-0"
N.T.S.
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355 REF
Revisions:
WALL TYPE
1 2 3 4 5
MTL STUD FRAMING GYP BD
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
FOR HEADER / JAMB FRAMING - REF 9
1/2"
1"
A7.4 2"
HOLLOW METAL DOOR FRAME
2"
2" FRAME DEPTH
Project #: CA13500.90 Date:
ANCHORS PER MANUFACTURER'S RECOMMENDATIONS @ 30" OC MAX & WITHIN 6" FROM EA END / CORNER
10 N.T.S.
NOT USED
8 N.T.S.
NOT USED
6 N.T.S.
PASS-THRU WINDOW ULTRAPURE TECHNOLOGY, INC. PT2424-24/MI/SSI
4 3/4" = 1'-0"
DOOR HEAD / JAMB
FR
Checked: JD
Sheet Title:
DOOR SCHEDULE & DETAILS
NOTE: FRAME DEPTH TO BE DETERMINED BY OVERALL WALL THICKNESS
NOT USED
12/30/15
Drawn:
1 3" = 1'-0"
A6.1
7
-1 07 - 3 1 R O F CA L I F O
N
R
ST
TE
IA
NO. C-32176
CARPET WHERE OCCURS
1/2"
7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 8' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 8' - 0" 7' - 0" 8' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"
1 1 1 1 1 REF HDWR SET 5 1 1 1 1 1 1 1 1 A 5 1 1 1 1 1 1 1 A 5 1 1 5 1 1 (E) 1 1 1 1 1 1 REF ELEVS 5 1 1 1
4"
3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 4' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 4' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 4' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 4' - 0" 3' - 0" 3' - 0" 3' - 0"
PT PT PT PT PT PT
REF SCHED
209A 210A 211A 212A 215A 216A 217A 218A 219A 219B 220A 221A 222A 224A 225A 226A 227A 229A 230A 231A 232A 233A 234A 234B 235A 236A 237A 238A 246A 248A 249A 250A
5
HM HM HM HM HM HM
REF SCHED
7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"
REF SCHED
3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0" 3' - 0"
REF SCHED
202A 203A 204A 205A 206A 208A
DESCRIPTION
3 1 1 3
FACTORY FINISHED WOOD - ROTARY CUT NATURAL BIRCH PAINT PLASTIC LAMINATE ANODIZED ALUMINUM
PT PL ANOD
5
TYPE 1: QTY
C
HEIGHT
PANEL TYPE
DETAILS
MATERIAL HM HOLLOW METAL SCWD SOLID CORE WOOD AL ALUMINUM
S
WIDTH
FRAME
GENERAL NONE NR NON-RATED
JA
DOOR NUMBER
DOOR
FIRE RATING
CLEAR OPENING
DOOR HARDWARE
METAL STUD OPENING FRAMING -REF 11
18
16 WALL PER PLAN
L3x3x1/4 (4) #12 SMS
UNIT SUPPORT CURB (TYP)
1" RADIUS COVE FILLER STRIP EXISTING CONCRETE FLOOR
A7.1
EXHAUST FAN MOUNTING RAIL (TYP)
2" TYP
METAL STUD 16" OC MAX, XXXS162 -REF 13 16" MAX
A7.1 2'-0". MAX.
BRACE
6" x 16 GA STL PL
17
RESILIENT HOMOGENIOUS SHEET FLOORING PER SCHEDULE OF FINISHES
6" MIN. U.N.O.
1/2" Ø HILTI KB-TZ EXPANSION ANCHOR 3.25" MIN EMBED
PARALLEL TO MTL DECK FLUTES OR AT CONC SLAB
PLAN
ELEVATION
23
WALL BRACING TO STRUCTURE1
INTEGRAL COVE BASE DETAIL
1 1/2" = 1'-0"
19
14
EXHAUST FAN MOUNTING
3" = 1'-0"
9
MTL STUD BACKING
METAL STUD BACKING -REF 9
FASTENER (TYP) BASE TRACK XXXT150 -REF 5
4
MTL STUD WALL FRAMING
1 1/2" = 1'-0"
1" = 1'-0"
WALL FINISH (TYP.)
8" MAX. @ JAMB (TYP.)
MTL STUD LINTEL CONNECTION -REF 12
A7.1 A7.1 1. MTL STUD NOTES "XXX" REFERENCES STUD DEPTH, REF WALL TYPES A7.1 2. SLOTTED TRACK & BASE TRACK SHALL MATCH STUD GAUGE U.N.O. 3. BRIDGING CHANNEL REQ'D ONLY WHERE GYP BD / SUBSTRATE IS NOT INSTALLED FULL HT. ON BOTH SIDES OF WALL
4" 4" TYP TYP
1' - 4" VERIFY W/ EQUIPMENT
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
A7.1
2"
(E) CONC ROOF SLAB
A7.1 BRIDGING CHANNEL 4'-0" OC MAX -REF 7
MTL STUD
DUCTING - REF MECH
A7.1
SCC-XX-A COVE CAP. COLOR PER SCHEDULE OF FINISHES.
(3) #12 SMS
VERIFY W/ EQUIPMENT
4" MIN
1 1/2" MIN
1' - 9 3/4"
1 1/2" MIN
A7.1
PROVIDE OPENING IN ROOF STRUCTURE - COORDINATE DIMENSION W/ MECH DUCTING
2' - 0" MAX.
A7.1
13'-0" MAX
SLOTTED TRACK -REF 10
4' - 0" MAX.
5
FOR MTL TRACK SPLICE -REF 6 13'-0" MAX. A7.1
1/4" = 1'-0" GYP BD (DELETE ON INACCESSIBLE SIDE WHERE OCCURS)
WALL FINISH (TYP.)
COORDINATE W/
MTL STUDS
MTL STUDS
MECH DUCTING
SOUND ATTENUATION INSULATION
ACOUSTICAL INSUL SS COLLAR BAND RAIN COLLAR SS COLLAR BAND
2"
5/8" GYP BD
3"
362T150 - 16 GA MTL STUD TRACK -FASTEN TO EACH VERTICAL STUD W/ #12 SMS EA FLANGE
METAL STUD (TYP.)
MTL. STUD (TYP.)
A7.1
FOR ROOFING -REF 16 SIM A7.1
5"
MTL STUD TRACK -REF 4
(E) CONC SLAB
A
T-INTERSECTION - PLAN
C
0.145" DIA RAMSET 1500 SERIES SHOT PINS - EMBED 1 1/2" AT CONC SLAB
INTERSECTION - PLAN
MTL STUD TRACK ATTACHMENT -REF 5 A7.1
GLASS WALL SYSTEM HEAD
DOUBLE MTL. STUDS 1/2" GAP
GLAZING
SLOTTED TRACK -REF
(E) ROOF STRUCTURE
VERTICAL MULLION (BEYOND) WHERE OCCURS (REF INTERIOR ELEVATION)
EXTEND 24 GA GALV MTL COPING UP 2" AT SHT MTL DUCT
(N) ROOF OPENING COORDINATE W/ MECH DUCT
NOTE:
10
WALL BASE
A7.1
MTL STUD
FLOOR FINISH
DO NOT FASTEN GYP BD TO TRACK (TYP) 2" X 16 GA STL PLATE 16" OC MAX SOUND ATT INS
1. PROVIDE MASTIC BETWEEN MTL COPING / RAIN COLLAR AND SHT MTL EXHAUST DUCT AS INDICATED
(N) SHT MTL EXHAUST DUCT
B
D
END - PLAN
(E) CONC FLOOR STRUCT
CORNER - PLAN
SEALANT & BACKER ROD
2. CONTRACTOR SHALL X-RAY SLAB TO AVOID DISTURBING REINFORCING
22
GLASS WALL HEAD
DUCT PENETRATION THRU ROOF
18
13
MTL STUD WALL DETAILS
1 1/2" = 1'-0"
3" = 1'-0"
0' - 4" MIN
MTL TRACK TO CONC SLAB
1" = 1'-0"
8
3
TYP WALL BASE
3" = 1'-0"
3" = 1'-0"
0' - 4" MIN
#10 SMS
A7.1
1 1/2" x 1 1/2" x 16 GA
CUT PART OF TRACK & BEND DOWN
5 (2) #10 SMS
(E) CONC FLOOR STRUCTURE
BASE RAIL
16 GA MTL STUD (TYP)
VIBRATION ISOLATOR AT EXHAUST FAN ONLY
A
JAMB SECTION
FASTENER W/ NEOPRENE WASHER (E) ROOFING PLIES MASTIC
362S162 - 20 GA MTL STUDS @ 8' OC MAX & 12" FROM EA END W/ (4) #12 SMS EA END
4" OVERLAP
4" OVERLAP
SOUND ATTENUATION INSULATION
INFUSION AREA
22 A7.1 INFUSION 7
VERTICAL MULLION (BEYOND) WHERE OCCURS (REF INTERIOR ELEVATION)
600S162-XX GA
XXXS125-20 GA x 16" LONG
7
400S162-XX GA
MTL STUD WHERE OCCURS
1
2
2
2
2
W = 0' TO 4'-0"
3
3
4
4
4
5
7
6
C
W = 4'-1" TO 8'-0"
6"
D
W = 8'-1" TO 10'-0"
E
MTL STUD OPENING FRAMING
(E) FINISHED FLOOR
Architect/Engineer of Record MTL STUD MTL STUD TRACK
CONC SLAB EXTRA ANCHOR
MTL STUD NOTE "XXX" REFERENCES STUD DEPTH, REF WALL TYPES
11
MTL STUD TRACK SPLICE
1 1/2" = 1'-0"
NON-RATED PARTITION - TYPE 2
6
SLOTTED TRACK
PIPE/CONDUIT
1' - 7 3/4" VERIFY W/ EQUIP
MOUNTING TAB (TYP)
17 A7.1 SIM
" 1/2
0.145" DIA RAMSET 1500 SERIES SHOT PINS @ 16" OC MAX - EMBED 1 1/2"
2
8 A7.1
Revisions: (E) CONC SLAB
1 2 3 4 5
CONTINUE GYP BD TO STRUCTURE ABOVE
CUT OPENING
PIPE/CONDUIT PENETRATION BASE TRACK
METAL STUD
MTL STUD @ 16" OC MAX 362S162 - 20 GA @ WALL TYPE 1A 600S162 - 20 GA @ WALL TYPE 1B 800S162 - 20 GA @ WALL TYPE 1C
UNIT SUPPORT CURB (TYP)
" 1/2
" 1/2
3 A7.1 2". MIN
/2" 11
3/4" = 1'-0"
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
5/8" GYP BD EA. SIDE (DELETE ON INACCESSIBLE SIDE WHERE OCCURS)
#8 SMS EA. LEG
SIM
2
20
-1 07 - 3 1 R O F CA L I F O
5
Project #: CA13500.90
Drawn:
FR
(E) CONC FLOOR
16 A7.1
1" MAX. TYP.
MTL STUD PER WALL TYPE
EN .
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355
BASE TRACK
#8 x 9/16" LONG WAFER HEAD SCREW ON BOTH SIDES F RE ALL W PE TY
21 A7.1
TE
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
1" = 1'-0"
1/2" = 1'-0"
4" 4" TYP TYP
AC UNIT ABOVE -REF MECH
A RCH S ED I EN A . DO T N N O
Project Title:
BOTTOM TRACK SPLICE DETAIL
CEILING WHERE OCCURS
0'-0"
WALL SECTION
3 A7.1
W = 10'-1" TO 14'-0"
1. "XXX" REFERENCES STUD DEPTH, REF WALL TYPES 2. GUAGE OF HEADER AND JAMB FRAMING SHALL MATCH ASSOCIATED WALL TYPE.
16
ACOUSTICAL SEALANT AT OPENINGS, VOIDS, & PENETRATIONS
NO. C-32176
MTL STUD NOTE:
1" (TYP) 1' - 0 1/4" VERIFY W/ EQUIP
6"
TOP TRACK SPLICE DETAIL
XXXS125-20 GA x 16" LONG
5/8" GYP BD EA SIDE
LI
3
3" = 1'-0"
(E) FIN FLR
(E) CONC FLOOR
6
1" MIN. TYP.
TEMPERED BUTT GLAZING
EXHAUST FAN SUPPORT CURB
GLASS WALL & DOOR SYSTEM
WINDOW HEAD 7'-2"
XXXS162-XX GA
6" EXTRA ANCHOR
HEADER SECTIONS
SUSPENDED CLG REF RCP
5
1
B
1/2-INCH DIAMETER SIMPSON TITEN HD AT 16" OC MAX SPACING
SUSPENDED CLG
XXXT150-XX GA
6"
MAX.MAX.
MIN
4" OVERLAP
4
1
4
4" MTL COPING
MTL. PL-8 x 3 x 16 GA
MTL STUD @ 16" OC MAX 362S162 - 20 GA
DELETE GYP BD ON INACCESSIBLE SIDE WHERE OCCURS
14' - 0" +/- MAX
362S162 - 20 GA MTL STUDS @ 16" OC MAX W/ 5/8" GP BD EA SIDE
3
SLOTTED TRACK (TYP)
A
MIN
#12 SMS 16" OC (TYP)
R
30
MTL STUD BRACING CONNECTION TO (E) ROOF STRUCTURE
MA X
0' - 3 1/4"
45°
2
Agency Approval:
SOUND ATT INS
ST
MTL STUD TRACK & CONNECTION TO (E) ROOF STRUCTURE
MTL. STUD PER FLOOR PLAN
CEILING WHERE OCCURS
T EC E TJ
BO (E) ROOF STRUCT 14'-0" +/-
1
1
(E) CONC ROOF STRUCTURE
3" = 1'-0"
1.25".
(E) ROOF STRUCTURE
(N) ROOFING PLIES
23 A7.1
7
C
MTL. PL-8 x 3 x 16 GA. w/ (2) #12 SMS 16" OC (TYP)
PT 4x6 FLAT SUPPORT BLOCKING
MTL STUD BRIDGING
1/2" = 1'-0"
3" = 1'-0"
24 GA GALV MTL COPING O/ BITUMINOUS SELF ADHESIVE FLASHING
8 A7.1
12
MTL STUD LINTEL CONNECTION
A7.1
JA
3" = 1'-0"
17
FOR ADDITIONAL FRAMING INFORMATION -REF 4
ALTERNATE BRACE DIRECTION WHERE REQ'D REF REFLECTED CEILING PLAN
EXHAUST FAN SUPPPORT CURB ATTACHMENT
23 A7.1
X MA 45° MIN 30°
21
GLASS WALL SILL
5' - 0" MAX
METAL STUD
1/2-INCH DIAMETER SIMPSON TITEN HD AT 16" OC MAX SPACING
COPE AND CUT STUD BRACE FLANGES AS REQ'D ATTACH TO STUD TRACK W/ (8) #12 SMS (2 ROWS OF 4) AT EA BRACE
CONDENSING UNIT MOUNTING
15 1" = 1'-0"
SEALANT AT OPENINGS, VOIDS, & PENETRATIONS
Date:
SOUND ATTENUATION INSUL WHERE WALLS ENCLOSE A ROOM FOR ADDITIONAL FRAMING INFORMATION -REF 4
Sheet Title:
12/30/15
Checked: JD
FRAMING & ROOFING DETAILS
A7.1 (E) FINISHED FLOOR
SLOTTED MTL TRACK
10 3" = 1'-0"
WALL TO FLR & PIPE PENETRATION
5
1 1/2" = 1'-0"
NON RATED PARTITION - TYPE 1
1 1" = 1'-0"
A7.1
IA
MIN
0' - 3 1/4"
4'-0" MAX
(2) #12 SMS (TYP)
(E) CONC SLAB
7
GLASS WALL SILL SIMPSON STRONG TIE TITEN HD SCREW ANCHOR @ 16" OC MAX W/ 1-1/2" MIN EMBEDMENT
362T150-18 GAUGE AT 4'-0" OC PERP. TO WALL W/ BRACE WITHIN 6" FROM EA END OF WALL
(2) #12 SMS (TYP)
N
A7.1
075U50 - 16 GA CHANNEL
4"
TEMPERED BUTT GLAZING
11A
S
FOR ADDITIONAL NOTES AND ROOFING REQUIREMENTS -REF 16
VERTICAL MULLION (BEYOND) WHERE OCCURS (REF INTERIOR ELEVATION)
6".
METAL STUD
FASTENER W/ NEOPRENE WASHER
4'-0" MAX
PT 4x6 FLAT SUPPORT BLOCKING
COMPRESSION STRUT CALCULATION: SINCE THE MAXIMUM SLENDERNESS RATION (KL/R) IS 200, THE RESULTING EULER BUCKING STRESS, DIVIDED BY A FACTOR OF SAFETY OF 23/12 IS: Fa= 12(n²) 29e6(1.33))/23(200²))= 4970 PSI 2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
USE MIN 1-5/8"x25 GA MTL STUD FOR MAX LENGTH 7'-2" 1 1/2" MIN
1 1/2" MIN
12 GA HANGER WIRE
A=0.078 IN² Rx=0.430 IN Fa=274#/0.078 IN²=3513 PSI
(E) CONC SLAB
4" MIN
MAIN RUNNER
USE MIN DBL 1-5/8"x25 GA SS MTL STUD MAX LENGTH 16'-10"
3 TIGHT TURNS WITHIN 1 1/2"
A=0.078 IN² Rx=0.686 IN Fa=274#/0.078 IN²=3513 PSI
CROSS TEE
1/2" Ø HILTI KB-TZ EXPANSION ANCHOR 3.25" MIN EMBED
(4) #12 SMS BRACE
@ 18" OC MAX
ACOUSTIC CLG TILE
24
NOT USED
N.T.S.
19
WALL BRACING TO STRUCTURE
14
9
HANGER WIRE TO CEILING GRID
1 1/2" = 1'-0"
N.T.S. 14 A7.2
L-MAX=200(O.686)=137.2"
NOTE: FOR COMPRESSION POST ASSEMBLY AT SUSPENDED CLG REF 3 A7.2 #6 SDST SCREWS
L3x3x1/4
NOT USED
L-MAX=200(O.430)=86.0"
4
MTL STUD COMPRESSION STRUT SIZES
3" = 1'-0"
3" = 1'-0"
(E) CONC ROOF SLAB LESSER OF 8" MAX 0.25 x LENGTH OF END RUNNER
FOR ATTACHMENT ABOVE REF 5 A7.2
3/4" MIN CLR.
METAL STUD COMPRESSION POST REF 4
HANGER WIRE HORIZ 6" RINGSHANK NAIL
ACOUSTIC CLG TILE
MAIN RUNNER
23
NOT USED
N.T.S.
METAL STUD SOFFIT
13
LESSER OF 8" MAX 0.25 x LENGTH OF END RUNNER
9' - 6"
HANGER WIRE
12 GA HANGER WIRE
3 TIGHT TURNS WITHIN 1 1/2"
2 - #8 SMS EA SIDE TO MAIN RUNNER OR PROVIDE SEISMIC HOLD DOWN CLIPS CAPABLE OF RESISTING ANY DIRECTIONAL FORCE EQUAL TO FIXTURE WEIGHT
8' - 6"
3 TIGHT TURNS WITHIN 1 1/2"
6"
SLIM PERIMETER TRIM DETAIL
SUSPENSION SYSTEM
1. ATTACH ALL LIGHT FIXTURES TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES 2. SUPPORT SURFACE MOUNTED LIGHT FIXTURES BY AT LEAST TWO POSITIVE DEVICES WHICH SURROUND THE CEILING RUNNER AND WHICH ARE EACH SUPPORTED FROM THE STRUCTURE ABOVE BY A 12 GA WIRE - SPRING CLIPS OR CLAMPS THAT CONNECT ONLY TO THE RUNNER ARE NOT ACCEPTABLE 3. SUPPORT PENDANT MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRUCTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE FIXTURE - SPECIAL DETAILS ARE NECESSARY FOR THIS CONDITION AT THE CEILING GRID
ACOUSTIC CLG TILE 1' - 0"
17
LIGHT FIXTURE AT T-BAR CLG
1 1/2" = 1'-0"
N.T.S.
TYP
1.
INSTALLATION: SURROUND EACH PANEL WITH A MAIN RUNNER, CROSS RUNNER, OR LEDGER ANGLE.
2.
COMPONENTS: SYSTEM SHALL SUPPORT NO OTHER COMPONENTS EXCEPT GRILLES OR LIGHT FIXTURES.
3.
HANGER WIRES: MINIMUM 12 GAGE, MAXIMUM 16 SF. NO SPLICES PERMITTED.
4.
PERIMETERS: HANGER WIRE WITHIN 8 INCHES OF SUPPORT OR WITHIN 1/3 OF LENGTH OF END TEE, WHICHEVER IS LESS.
5.
ATTACH SYSTEM TO NOT MORE THAN 2 ADJACENT WALLS; LEAVE 1/2" FREE OF OTHER WALLS.
6.
PROVIDE STRUTS OR 16 GAGE WIRE TO CONNECT FREE END OF CROSS RUNNERS MORE THAN 12 INCHES FROM WALL.
7.
SPLAYED BRACING: SETS OF FOUR, 12 GAGE MINIMUM, MAXIMUM SPACING OF 12 x 8 FEET. PROVIDE VERTICAL COMPRESSION STRUT AT EACH SET OF BRACING WIRES.
8.
DISTANCE OF SPLAYED BRACING FROM WALL: MAXIMUM 4 FEET.
9.
SLOPE OF BRACING WIRES: 45 DEGREES FROM PLANE OF CEILING. MAINTAIN WIRES TIGHT; NO SPLICES PERMITTED.
ACOUSTIC CEILING TILE
MAIN RUNNER
2"
3" = 1'-0"
MAIN RUNNER OR CROSS TEE
1/2" MIN
USG COMPASSO SLIM PERIMETER TRIM
12
3
METAL STUD COMPRESSION STRUT
3" = 1'-0"
WIRE HANGER PLACED ON DIAGONAL CORNERS (2) EXCEPT 4'x4' FIXTURES SHALL HAVE HANGERS AT EACH CORNER (4 TOTAL)
12 GA HANGER WIRE
22
8
T-BAR CEILING PERIMETER - SLIP JOINT
3/4" = 1'-0"
5
LIGHT FIXTURE (56 LBS MAX)
NOT USED
CROSS TEE
WALL
GYP BD SOFFIT WHERE OCCURS
18 N.T.S.
45°
(2) #12 SDST SCREWS
SUSPENDED CLG WHERE OCCURS
NOT USED
LATERAL FORCE BRACING, (4) AT EA COMPRESSION STRUT W/ 12 GA WIRE SECURED TO MAIN RUNNER WITHIN 2' OR CROSS TEE INTERSECTION AND SPLAYED 90° FROM BOTH DIRECTIONS W/ FIRST POINT WITHIN 6" FROM STARTING CORNER
3 TIGHT TURNS WITHIN 1 1/2"
1" X 2" GA CONT ANGLE W/ (1) #10 SMS INTO WALL STUD (24" OC MAX).
GYP BD BULKHEAD WHERE OCCURS
12 GA VERTICAL HANGER WIRE @ 4' OC
A7.2
MAIN RUNNER OR CROSS TEE
3 -5/8" MTL STUDS @ 16" O.C. MAX 362S162- 20 GA
6" MIN
H/3
H
° -60 30°
362S162- 20 GA MTL STUD BRACE @ 48" O.C. MAX & 12" MAX FROM EA END W/ (4) #12 SMS AT VERTICAL HANGER STUD
METAL STRUT
10. THREE TIGHT TURNS REQUIRED AT HANGER WIRE; 4 TIGHT TURNS AT BRACING WIRES, ALL WITHIN 1-1/2". ALIGN WIRES IN DIRECTION OF PULL. 11. SEPARATE WIRES 6 INCHES FROM UNBRACED DUCTS, PIPES OR CONDUIT. CONDUIT 3/4" DIAMETER OR LESS MAY BE ATTACHED TO WIRES USING APPROVED CONNECTORS.
ALUM POP RIVET 1" X 2" GA CONT ANGLE W/ (1) #10 SMS INTO WALL STUD (24" OC MAX).
12. LIGHT FIXTURES: ATTACH TO CEILING SYSTEM TO RESIST HORIZONTAL FORCE EQUAL TO WEIGHT OF FIXTURE.
WALL
13. SUSPENSION SYSTEM: HEAVY DUTY
7
T-BAR CEILING PERIMETER - FIXED
1 1/2" = 1'-0"
2
SUSPENDED T-BAR CEILING NOTES
3" = 1'-0"
6" = 1'-0"
Agency Approval:
BRACING WIRE 1" WIDE X 12 GA STL STRAP (E) CONC SLAB
PREFAB DIFFUSER (REF MECH)
(E) WALL
12 GA HANGER WIRE MIN (4) PER FIXTURE 3/8" Ø HILTI KB-TZ EXP ANCHOR W/ 2" MIN EMBED
Architect/Engineer of Record AT BRACING WIRE
A
N
13 GA x 3/4" CEILING CLIP HANGER WIRE
COMPRESSION STRUT
AT HANGER WIRE
16
MECH DIFFUSER AT T-BAR CLG
HANGER WIRE TO METAL DECK
1 1/2" = 1'-0"
3" = 1'-0"
N.T.S.
11
EQ
6 3" = 1'-0"
4'0" TY P
ROLLER WINDOW SHADE
4 A7.2
5
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
A7.2
CROSS RUNNER (TYP)
45
45
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355
W
EQ
S P TY 0" 4'-
HANGER WIRE
MAIN RUNNER (TYP)
EQ
CLG GRID (TYP)
FROM BRACING WIRES TO COMP POST & X-RUNNER
AUTOMATIC FIRE SPRINKLER HEAD, SMOKE DETECTOR OR OTHER DEVICES
CTSK. S.M.S. @ 2'-0" O.C. MIN.
12 GA HANGER WIRES 4'-0" OC EA WAY W/ (3) TIGHT TURNS IN 1 1/2" BOTH ENDS (TYP)
1-1/2" x 1-1/2" X 16 GA ANGLE (2) # 12 SDST SCREWS
EQ
20 N.T.S.
CURTAIN TRACK AT LAY-IN CEILING
EQ
15 3" = 1'-0"
EQ
CEILING DEVICES HORIZ CONTROL
10
1 1/2" = 1'-0"
COMPRESSION STRUT TOP ATTACHMENT
8 A7.2
Project #: CA13500.90
9 A7.2
Date:
NOTES: 1. COMPRESSION STRUTS: STEEL SECTION WITH L/R RATIO OF 200 MAX STARTING NOT MORE THAN 3'-0" FROM ADJACENT WALLS TO SUPPORT A TRIBUTARY AREA OF 144 SF 2. COMPRESSION STRUT SHALL NOT REPLACE HANGER WIRE. 3. REFER TO CEILING DEVICE HORIZONTAL CONTROL FOR CEILING MOUNTED DEVICES REF 10 4. FOR GRILLE / DIFFUSER AND LIGHT FIXTURE ATTACHMENT REF 12 5. FOR ADDITIONAL NOTES REF A7.2 2 A7.2 A7.2
DIFFUSER OR GRILLE
EQ
NOT USED
7 A7.2
MTL STUD COMPRESSION STRUT L/R RATIO LESS THAN 200
CURTAIN TRACK
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
MA 2" X 2 MA " X
3/8" Ø HILTI KB-TZ EXPANSION ANCHOR W/ 2" MIN EMBED
ACOUSTICAL CEILING PANEL
CURTAIN
1 2 3 4 5
45
EQ
MAIN RUNNER OR CROSS TEE
Revisions: 45
(E) CONC SLAB
5 3" = 1'-0"
SUSPENDED T-BAR CEILING
12/30/15
Drawn:
Checked: JD
Sheet Title:
CEILING DETAILS
1 3" = 1'-0"
FR
A7.2
IA
-1 07 - 3 1 R O F CA L I F O
Project Title: 3 A7.2
E
21
EN .
12 GA BRACING WIRE W/ (4) TIGHT TURNS IN 1 1/2" BOTH ENDS TYP
T-BAR CEILING GRID
NOT USED
TE
7
(E) CONC SLAB
R
ACOUSTIC TILE CEILING PANEL
SHADE FABRIC
NO. C-32176 ST
MANUAL CHAIN
JA
0.145" DIA SHOT PIN W/ 1" MIN EMBED
FASCIA
S
LI
C
3 TIGHT TURNS IN 1 1/2" (TYP)
T EC E TJ
BRACKET ASSEMBLY
A RCH S ED I EN A . DO T N N O
N
12 GA HANGER WIRE 4'-0" OC MAX (TYP)
(E) WINDOW FRAME
2' - 8" OC MAX 2' - 5"
20
COUNTERTOP -REF
1' - 0"
9
FACE OF FINISH
A7.3
EQ
2' - 0"
1/4" x 2 1/2" BOLT OVER 1/4" WASHER WITH 1/4" NUT CENTERED WITHIN STUD
A7.3
WALL 2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
4" BACK SPLASH
EQ
WIRE MOLD WHERE OCCURS (REF ELEC)
2" EQ
FOR CABINET ANCHORAGE -REF 16 2'-10"
2'-7"
1 1/2" DIA. NUMNER DISC, TYP. ALL LOCKERS
METAL STUD PER WALL TYPE PER PLAN, TYP. #12 TEK SCREW LOCATIONS, TYP 2" x 2" x 12 GA TS SUPPORT BRACKETS
A7.3
A7.3 DRAWER BACK PANEL
2"
PLASTIC LAMINATE LOCKER DOOR DOOR HINGE
20
COUNTERTOP -REF
EQ
HARDWOOD BLOCKING
2' - 2" MAX
3"
EQ
DRAWER PULL
EQ
WALL 4" BACK SPLASH
EQ 2"
FILE DRAWER -PROVIDE LOCK
2".
FOR PLAN VIEW -REF 10 A7.3
2" x 2" X 12 GA TS SUPPORT BRACKETS 1/4" X 2 1/2" BOLT OVER 1/4" WASHER WITH 1/4" NUT CENTERED WITHIN STUD WIRE MOLD WHERE OCCURS GYP BOARD WALL
18 A7.3
17
PLASTIC LAMINATE LOCKERS
13
DRAWER CABINET & TRANSACTION COUNTER
1" = 1'-0"
9
COUNTERTOP SUPPORT
1" = 1'-0"
1" = 1'-0"
(E) WALL
20 A7.3
1". 1/4" RADIUS EASED EDGE AT WORK AREAS
1/4".
FILE DRAWER -PROVIDE LOCK BOTTOM PANEL
DOOR PULL
REMOVABLE BACK PANEL CABINET DOOR WHERE OCCURS -PROVIDE LOCK WHERE INDICATED ON INTERIOR ELEVATIONS
ADJUSTABLE SHELVING W/ SEISMIC PINS FOR CABINET ANCHORAGE -REF 16 A7.3
RECEPTION AREA DRAWER CABINET UPPER CABINET
UPPER CABINET
1" = 1'-0"
ACCESSIBLE SINK
FAUCET
COUNTERTOP -REF
20 COUNTERTOP -REF 20
FIXED PANEL
FOR CABINET ANCHORAGE -REF 16
PLUMBING PIPE ESCUTCHEON
ADJUSTABLE SHELVING W/ SEISMIC PINS BACK PANEL
WALL REMOVABLE BACK PANEL EXTEND FINISHED FLOOR UNDER CABINET
BOTTOM PANEL
6" MAX 17" MIN
16
TYP CABINET ANCHORAGE
3" = 1'-0"
INFUSION AREA SHELVING BACK PANEL
3/4" = 1'-0"
7
ACCESSIBLE EXAM ROOM SINK
1" = 1'-0"
NO. C-32176
2
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355 ACCESSIBLE SINK
FAUCET
COUNTERTOP -REF
COUNTERTOP
2' - 0"
HARDWOOD BLOCKING COUNTERTOP -REF
(1) #8 FHWS w/ FINISH WASHER @ EA. CORNER
A7.3
Revisions:
A7.3
1 2 3 4 5
A7.3
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
FIXED PANEL
ADJUSTABLE SHELVING
PLUMBING PIPE ESCUTCHEON
#8 x 1-1/2" SMS @ 12" OC MAX
WIRE MOLD WHERE OCCURS (REF ELEC)
FINISH FLOOR
WALL BASE
19 A7.3
CABINET DOOR WALL
9" MIN
(E) CONC SLAB
FOR CABINET ANCHORAGE -REF 16 A7.3
27" CLR MIN
2' - 7"
FLOORING
2' - 10"
TOE KICK BLOCKING
CABINET DOOR PULL 2' - 10"
PROVIDE COUNTERTOP SUPPORT AT NURSE STATION -REF 9 SIM A7.3
3' - 6"
BASE
6" MAX 17" MIN
BASE CABINET FLOOR CONNECTION
20
FOR CABINET ANCHORAGE -REF 16
20 A7.3
20
CABINET DOOR (WHERE OCCURS)
0' - 4"
8" MIN
DOOR PULL
6" TO CL OF BACKING
0' - 3"
CONT 3x3x16 GAUGE STL ANGLE - ATTACH TO (E) CONC SLAB W/ 0.157" DIA HILTI X-U POWDER DRIVEN FASTENERS @ 24" OC MAX AND 3" MAX FROM ENDS, 1-1/4" MIN EMBEDMENT
CL
7' - 0".
11"
-1 07 - 3 1 R O F CA L I F O
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
1" = 1'-0"
2' - 1 1/4"
EN .
Project Title:
24" 2' - 6"
TE
A
NOTES 1. KNEE AND TOE SPACE (SHADED AREA) SHALL BE PROVIDED AS REQ'D BY CBC TABLE 1115B-1 2. HOT WATER AND DRAIN PIPES UNDER SINKS SHALL BE INSULATED OR OTHERWISE COVERED 3. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER SINKS
CABINET DOOR
19
A RCH S ED I EN A . DO T N N O
R
EACH CABINET MODULE TO BE ANCHORED TOP & BOTTOM TO BACKING W/ (3) HILTI S-MD 10-16 x 1" SCREWS @ 16" OC MAX AND 2" MAX FROM END - FOR BACKING REF 9 A7.1
LI
2'-6"
A7.3
Architect/Engineer of Record
PROVIDE METAL CLIPS FOR REMOVABLE FRONT PANEL
9" MIN
FINISHED FLOOR
WALL
ST
3" TO CL OF BACKING
BASE CABINET
A7.3
27" CLR MIN
1' - 6"
A7.3
18 3" = 1'-0"
TRANSACTION COUNTER
15 1" = 1'-0"
FULL HEIGHT STORAGE CABINET
11 1" = 1'-0"
EQUIPMENT BASE SUPPORT
6 1" = 1'-0"
REMOVABLE BACK PANEL EXTEND FINISHED FLOOR INTO CABINET INTEGRAL TOE KICK NOTES 1. KNEE AND TOE SPACE (SHADED AREA) SHALL BE PROVIDED AS REQ'D BY CBC TABLE 1115B-1 2. HOT WATER AND DRAIN PIPES UNDER SINKS SHALL BE INSULATED OR OTHERWISE COVERED 3. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER SINKS
ACCESSIBLE SINK BASE CABINET
1 1" = 1'-0"
Project #: CA13500.90 Date:
12/30/15
Drawn:
FR
Checked: JD
Sheet Title:
CASEWORK AND MISC. DETAILS
A7.3
IA
4"
WALL
20
FOR CABINET ANCHORAGE -REF 16
A7.3 BASE CABINET TO BE ANCHORED SIM TO UPPER CABINET
18 A7.3
CASEWORK WALL TO FLOOR CONNECTION
Agency Approval:
7
A7.3
7"
(E) CONC SLAB
1" = 1'-0" 8" MIN
12"
COUNTERTOP -REF
3
T EC E TJ
WALL BASE (TYP)
BASE CABINET 24"
WALL
REF CABINET DETAILS
A7.1
8 1" = 1'-0"
CASEWORK PANEL FOR MTL STUD TRACK & FASTENER -REF 5
BOTTOM PANEL
N
ELEVATIONS
REF INTERIOR
1 3/4" @ WORK SURFACE 2-1/2" @ TRANSACTION COUNTER
12
NOTE: REF INTERIOR ELEVATIONS FOR SPECIFIC CABINET TYPES
NOTE: REF INTERIOR ELEVATIONS FOR SPECIFIC CABINET TYPES
2".
3" = 1'-0"
18"
2' - 10"
20
COUNTERTOP EDGE DETAIL
BACK PANEL
PROVIDE 18" DEEP BOTTOM SHELF AT CONFERENCE ROOM 226
19 A7.3
A7.3
C
2".
AT PLASTIC LAMINATE COUNTERTOP
18 A7.3
EACH CABINET MODULE TO BE ANCHORED TOP & BOTTOM AT FRAMED WALL W/ (3) #10 PAN HEAD SMS @ 16" OC MAX AND 2" MAX FROM END - PROVIDE BACKING PER 9 A7.1
REF CABINET DETAILS
CABINET DOOR (WHERE OCCURS)
20
COUNTERTOP -REF
CABINET DOOR PULL WHERE OCCURS
COUNTERTOP BLOCKING
FLOORING
CABINET DOOR
ADJUSTABLE SHELVING W/ SEISMIC PINS
REF INTERIOR ELEV
2'-7"
1 3/4".
3/4".
BACK PANEL
WD BLOCKING
4" BACK SPLASH
A7.3
DRAWER PULL
SOLID BLOCKING WHERE OCCURS
WALL
FOR CABINET ANCHORAGE -REF 16
2'-10"
COUNTERTOP -REF
4
2' - 0"
2' - 0"
BACKING SHEET
BACK PANEL
1" = 1'-0" 12"
AT PLASTIC LAMINATE WORK SURFACE
PLYWOOD COUNTERTOP
ADJUSTABLE SHELVING W/ SEISMIC PINS
BASE CABINET W/ DRAWER
2' - 5"
PLASTIC LAMINATE
CABINET DOOR
BOTTOM PANEL
COUNTERTOP BLOCKING
STL COUNTERTOP SUPPPORT
DOOR PULL
S
4".
3/4" BLOCKING W/ PLASTIC LAMINATE
A7.3
NOTE: PROVIDE GROMMETS @ 36" O.C.
19 A7.3
1 3/4".
3/4".
1' - 6"
FOR CABINET ANCHORAGE -REF 16
JA
1/4" RADIUS EASED EDGE AT WORK AREAS
PLYWOOD COUNTERTOP
A7.3
DRAWER PULL
BOTTOM PANEL FINISHED FLOOR PER FINISH PLAN
20
COUNTERTOP -REF
2" EQ
2'-7"
BACK PANEL
WALL BASE PER FINISH PLAN
20 A7.3
A7.3
1' - 6"
3'-6"
METAL STUD FRAMING
2' - 0"
2' - 2" CONT 3/4" HARDWOOD BLOCKING COUNTERTOP
DRAWER PULL
METAL STUD CROSS BRACING @ 2'-0" O.C.
EQ
20
COUNTERTOP -REF
2"
2"
1" = 1'-0"
2' - 4"
2" PLASTIC LAMINATE PEDISTAL CAP
PLASTIC LAMINATE
5
2' - 6" 11"
2' - 0"
1' - 10"
1" = 1'-0"
PROVIDE TALL DRAWER WHERE NOTED IN INTERIOR ELEVATIONS
EQ
1" = 1'-0"
DRAWER CABINET
2'-10"
EACH CABINET MODULE TO BE ANCHORED TOP & BOTTOM AT FRAMED WALL W/ (3) #10 PAN HEAD SMS @ 16" OC MAX AND 2" MAX FROM END PROVIDE BACKING PER 9 A7.1 2X LOCKER BASE
10
COUNTER SUPPORT PLAN
2' - 7" UNO
N.T.S.
14
RECEPTION AREA WORK SURFACE
27" MIN
MELAMINE INTERIOR FINISH
EQ
21 7' - 0"
NOT USED
BOTTOM PANEL
19 A7.3
KEYLESS MECHANICAL COMBINATION CODE LOCK
EQ
5' - 0"
COAT HOOK, TYP. ALL LOCKERS
NOTES: 1. LOCATE PER 3" MAX
GYP BD MTL STUD OPENING FRAMING
15
NOT USED
N.T.S.
FIRE EXTINGUISHER CABINET
36" GRAB BAR
BOBRICK
B-5806 x 36
B
42" GRAB BAR
BOBRICK
B-5806 x 42
C
MIRROR
BOBRICK
B-290 1830
D
PAPER TOWEL/TRASH RECEPTACLE
BOBRICK
B-43944
E
SEAT COVER DISPENSER
BOBRICK
B-4221
F
SOAP DISPENSER
--
--
G
SANITIZER DISPENSER
BOBRICK
B-6727
H
PAPER TOWEL DISPENSER
BRADLEY
250-33
I
TOILET PAPER DISPENSER
--
--
J
FEMININE NAPKIN DISPOSAL
--
--
13
1 1/2" = 1'-0"
N.T.S.
NOT USED
19
14
NOT USED
N.T.S.
1/2"
TEXT 11B-703.2.4 PROPORTIONS. VISUAL CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER "I". STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 10 PERCENT MINIMUM AND 15 PERCENT MAX OF THE HEIGHT OF THE CHARACTER.
NOTE: GRAPHICS SHALL BE OF CONTRASTING COLOR
ASSISTIVE LISTENING SIGNAGE
60" MAX AFF
NOTE: 1/8" THICK SIGN IS COMPRISED OF TWO LAYERS OF ACRYLIC MULTIPOLYMER PANELS WITH BULLNOSED EDGES. APPLIED TACTILE GRAPHICS (MACHINE ENGRAVED).
CONTRACTED GRADE 2 BRAILLE - RAISED 1/40" MIN
FINISH: CHARACTERS, SYMBOLS, PICTOGRAMS AND THEIR BACKGROUNDS SHALL HAVE A NONGLARE FINISH, SUCH AS MATTE, SATIN OR EGGSHELL.
COLOR & FINISH LEGEND: A WHITE B BLUE
5
UNISEX RESTROOM SIGNAGE
3" = 1'-0" 2 A7.4
2. PROVIDE SIGN ON ALL UNISEX RESTROOM DOORS UNO 3. SIGN COLOR SHALL DISTINCTLY CONTRAST WITH DOOR COLOR A
BRAILLE SYMBOLS: CALIFORNIA CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE SYMBOLS ARE REQUIRED BY EITHER THE CALIFORNIA BUILDING CODE OR THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES. BRAILLE SHALL BE LOCATED A MINIMUM OF 1/2" FROM TACTILE CHARACTERS. BRAILLE DOTS SHALL BE 1/10" ON CENTERS IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS. BRAILLE DOTS SHALL BE RAISED 1/40" MINIMUM ABOVE THE BACKGROUND. BRAILLE DOTS TO HAVE DOMED TOPS.
12
CONTRAST: CHARACTERS, SYMBOLS AND PICTOGRAMS SHALL CONTRAST WITH THEIR BACKGROUND, EITHER LIGHT CHARACTERS, SYMBOLS AND PICTOGRAMS ON A DARK BACKGROUND OR DARK CHARACTERS, SYMBOLS AND PICTOGRAMS ON A LIGHT BACKGROUND. A CONTRAST BETWEEN THE COLOR OF THE BACKGROUND AND THE COLOR OF THE CHARACTERS, SYMBOLS AND PICTOGRAMS OF AT LEAST 70% BASED ON THE LIGHT REFLECTANCE VALUE IS A RECOMMENDED. A CONTRAST BETWEEN THE BACKGROUND COLOR OF THE DOOR MOUNTED TOILET ROOM SIGN AND THE COLOR OF THE DOOR OF AT LEAST 70% BASED ON THE LIGHT REFLECTANCE VALUE IS RECOMMENDED.
A
APPLIED TACTILE GRAPHICS (MACHINE ENGRAVED) ACCESSIBLE RESTROOM SIGN IS COMPRISED OF TWO LAYERS OF ACRYLIC MULTIPOLYMER PANELS w/ BULLNOSED EDGES. APPLIED TACTILE GRAPHICS (MACHINE ENGRAVED). SHALL MEET CALIFORNIA ADA STANDARDS. -REF 9
B
A7.4 ACRYLIC MULTIPOLYMER PANEL 12" DIA COLOR & FINISH LEGEND: A WHITE B BLUE
9
SIGNAGE NOTES
3" = 1'-0"
N.T.S.
RESTROOM
1/4" = 1'-0"
8" 1/2"
1/2" TEXT
48" MIN AFF
1/2" TYP
ASSISTIVE LISTENING SYSTEM AVAILABLE
1/2"
A
"WOMEN"
NOTES: 1. LOCATE PER 1/4" RADIUS CORNERS
A
APPLIED TACTILE GRAPHICS (MACHINE ENGRAVED) ROOM IDENTIFICATION SIGN IS COMPRISED OF TWO LAYERS OF ACRYLIC MULTIPOLYMER PANELS w/ BULLNOSED EDGES. APPLIED TACTILE GRAPHICS (MACHINE ENGRAVED) AND BRAILLE RASTER BEADS. SHALL MEET CALIFORNIA ADA STANDARDS. SEE PROTOTYPE FOR SPECIFIC DETAILS.
1' - 0" INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
B
4. TYPEFACE / SYMBOLS: HELVETICA NEUE-ROMAN
10
TOILET ACCESSORY SCHEDULE
A7.4
SQUARE
A
A7.4
8 1/2"
PRODUCT #
3/8" MIN 1/2" MAX
MANUFACTURER
1/2".
DESCRIPTION
6".
48" TO OPERATING . DEVICE (HANDLE)
PROVIDE 5/8" TYPE "X" GYP BD AROUND CABINET AT 1-HR FIRE RATED WALL
KEYNOTE
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.228.7528
6" MIN
FIRE EXTINGUISHER
20
A7.4
2. PROVIDE SIGN AT ALL UNISEX RESTROOM DOORS UNO 3. FOR ADDITIONAL TEXT & BRAILLE NOTES SEE 8 9
SEMI-RECESSED FIRE EXTINGUISHER CABINET
NOT USED
2
4
UNISEX RESTROOM DOOR SIGNAGE
3" = 1'-0"
3" = 1'-0"
1 1/2"
1' - 0"
2/10" SPACE BETWEEN CELLS (LETTERS) CALIFORNIA GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED INDIVIDUAL BRAILLE DOTS SHALL EACH BE DISTINCT AND BE ROUNDED OR DOMED IN LIEU OF SQUARE SIDED AND FLAT TOPPED.
NOTE: PROVIDE MIN. 30" x 48" CLEAR FLOOR SPACE IN FRONT OF ACCESSORY TO ALLOW FORWARD OR PARALLEL APPROACH. HIGHEST OPERABLE PART AT MAX 3' - 4" AFF
8 3" = 1'-0"
3" = 1'-0" 4" MIN 12" MAX
NOTES:
NOTE: PROVIDE MIN. 30" x 48" CLEAR FLOOR SPACE IN FRONT OF ACCESSORY TO ALLOW FORWARD OR PARALLEL APPROACH. HIGHEST OPERABLE PART AT MAX. 3' - 4" AFF
CONTRACTED GRADE 2 BRAILLE, RAISED 1/40" MIN
APPLIED TACTILE GRAPHICS (MACHINE ENGRAVED) ROOM IDENTIFICATION SIGN IS COMPRISED OF TWO LAYERS OF ACRYLIC MULTIPOLYMER PANELS w/ BULLNOSED EDGES. APPLIED TACTILE GRAPHICS (MACHINIE ENGRAVED) AND BRAILLE RASTER BEADS. SHALL MEET CALIFORNIA ADA STANDARDS.
ACCESSIBLE URINAL
URINAL NOTE: DRAIN AND HOT WATER PIPING SHALL BE INSULATED AND THERE SHALL BE NO SHARP OR ABRASIVE ELEMENTS UNDER LAVATORY 18" MIN 17" MIN
2. SIGNS WITH RAISED CHARACTERS AND BRAILLE SHALL BE LOCATED 48" MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE LOWEST LINE OF BRAILLE AND 60" MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED CHARACTERS.
COLOR & FINISH LEGEND: CONTRASTING COLOR 1 CONTRASTING COLOR 2
TACTILE ROOM ID SIGN (OFOI)
7
C
4" MIN 12" MAX
DOOR SIGNAGE LOCATIONS
NOTES: 1. SIGN MATERIAL SHALL BE 1/8" THICK ACRYLIC PLASTIC WITH 1/32" RAISED BORDER, GRAPHIC, AND LETTERS. PROVIDE MECHANICAL MOUNTING WITH VANDAL RESISTANT FASTENERS. COMPLY WITH ARTICLE 4.30 & A4.30 OF ADAAG. 2. SEE FLOOR PLANS FOR LOCATION 3. FOR ADDITIONAL INFO, REF 8 9
23823 W VALENCIA BOULEVARD SANTA CLARITA, CA 91355
FF CONTROL / SWITCH / OUTLET HEIGHT OVER OBSTRUCTION
CONTROLS, SWITCHES & OUTLETS
A7.4
01/06/16 01/20/16 01/25/16 01/27/16 02/25/216
Project #: CA13500.90 MIN.
EXIT SIGN
12"
B
Date:
12/30/15
ADDENDUM 1 ADDENDUM 2 ADDENDUM 3 ADDENDUM 4 CITY RESUBMITTAL
Drawn:
16 N.T.S.
ACCESSIBLE ACCESSORY MOUNTING HEIGHTS
11
Sheet Title:
A7.4
1/2" = 1'-0"
TACTILE EXIT SIGNAGE (OFOI)
FR
Checked: JD
ACCESSIBILITY & MISC. DETAILS
NOTE: SOME ITEMS INDICATED MAY NOT BE USED
NOT USED
-1 07 - 3 1 R O F CA L I F O
Revisions:
60" MIN. CLR.
48" MIN. CLR.
A EXIT ROUTE SIGN
EXIT
EN .
SANTA CLARITA TENANT IMPROVEMENT SUITE 240, 250, 260
1 2 3 4 5 60" MAX AFF
60" MAX AFF 48" MIN AFF 3/8" MIN 3/8" MIN / 1/2" MAX
34" MAX
46" MAX
2' - 0" MAX
CONTRACTED GRADE 2 BRAILLE, RAISED 1/40" MIN, TO BE LOCATED DIRECTLY UNDER OR ADJACENT TO EXIT INFORMATION
TE
Project Title:
2
18" MIN
SANITARY NAPKIN DISPOSAL
48" MAX
40" MAX
19" MAX
CENTERLINE OF CONTROL / SWITCH / OUTLET TOP OF CONTROL/ SWITCH / OUTLET
EXIT ROUTE
3/8" MIN / 1/2" MAX
60" MIN. CLR.
LAVATORY
FF CONTROL / SWITCH / OUTLET HEIGHT, TYP
1265
1/4" = 1'-0"
6". MAX
3/8" MIN
8". MIN
KNEE CLEARANCE
PAPER TOWEL DISPENSER
ELECTRICAL ROOM
9" MIN CLR
27" MIN
CLR
29" MIN
34" MAX
40" MAX
NOTE: PROVIDE BLOCKOUT FOR FIXTURE WHERE CONCRETE CURB OCCURS
A RCH S ED I EN A . DO T N N O
NO. C-32176
3" = 1'-0"
N.T.S.
Architect/Engineer of Record
CL
6 3" = 1'-0"
DOOR CLEARANCES
1 1/2" = 1'-0"
A7.4
IA
TO VALVE
B
48" MIN AFF
17
44" MAX
17" MAX ACCESSIBLE URINAL
ACCESSIBLE TOILET / GRAB BARS
NOT USED
14" MIN 17" MAX
24".
17" MIN 19" MAX
33".
STANDARD URINAL
3. TYPEFACE / SYMBOLS: MATCH (E) SIGNAGE
9" MIN
A
12".
A7.4
A
R
12".
24" MIN
A7.4
ROOM NAME
T EC E TJ
12" MAX 42" MIN
9
ST
17" MIN 18" MAX
30" MIN CLR
8
A
48" MIN AFF 3/8" MIN / 1/2" MAX
EQ EQ
54" MIN 6" MAX
URINAL SCREEN WHERE OCCURS
60" MAX AFF
NOTES: 1. FLUSH VALVE TO BE LOCATED TO THE WIDE SIDE 2. PROVIDE GRAB BAR BACKING
2. FOR ADDITIONAL TEXT & BRAILLE NOTES REF
LI
TOILET
9" MIN CL
JA
TOILET TISSUE DISPENSER
A7.4
CL
STANDARD TOILET
9"
2 3/8" MIN / 1/2" MAX
SAN. NAPKIN DISPOSAL & TISSUE DISPENSER
1" MIN HIGH LETTERS IN CAPS
1. SIGNS SHALL BE INSTALLED ON THE 3. THE COLOR AND WALL ADJACENT TO THE LATCH SIDE OF CONTRAST OF THE THE DOOR. WHERE THERE IS NO WALL SIGN SHALL BE SPACE ON THE LATCH SIDE, INCLUDING DISTINCTLY DOUBLE LEAF DOORS, SIGNS SHALL BE DIFFERENT FROM PLACED ON THE NEAREST ADJACENT THE COLOR AND WALL, PREFERABLY ON THE RIGHT. CONTRAST OF THE MOUNTING LOCATION SHALL BE DOOR / WALL. DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3" OF SIGNAGE W/O ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A PER PLAN DOOR. FOR PAIRS OF DOORS WHERE DOOR SWING IS LIMITED TO 90 DEGREE EQ EQ MOUNT SIGN 9" FROM EDGE OF DOOR. ACCESSIBLE FOR PAIRS OF DOORS WHERE DOOR ROOM SIGN SWING EXCEEDS 90 DEGREES MOUNT ACCESSIBLE SIGN DOOR WIDTH PLUS 9" FROM EDGE OF DOOR SIGN DOOR.
5' - 0" AFF
1. LOCATE PER
6 - 1/2"
1' - 5".
19" MAX
NOTES:
Agency Approval:
7
7" - 9"
36" MIN
3
OCCUPANT LOAD SIGN
N
CHARACTER & BRAILLE STANDARDS
NOTE: ACCESSORIES SHALL BE FULLY RECESSED OR SEMI-RECESSED WITH A MAX 3" PROJECTION
S
3' - 4" MAX
SEAT COVER DISPENSER
MOUNTING HT
N.T.S.
MIRROR/ SOAP DISPENSER
NOTE: GRAPHICS SHALL BE OF CONTRASTING COLOR
REF NOTE 2 FOR
18
NOTE: 1/8" THICK SIGN IS COMPRISED OF TWO LAYERS OF ACRYLIC MULTIPOLYMER PANELS WITH BULLNOSED EDGES. APPLIED TACTILE GRAPHICS (MACHINE ENGRAVED).
60" MAX AFF
1/2" TEXT
48" MIN AFF
1/10" BY 1/10" GRID
40" MAX
NOT USED
8"
THE NUMBER OF PEOPLE PERMITTED IN THIS ROOM SHALL NOT EXCEED XXX BY ORDER OF THE STATE FIRE MARSHAL
MUSICK LAW CENTER (LAW) OFFICE 110 ALTERATIONS 2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.315.1993
UNIVERSITY OF SOUTHERN CALIFORNIA
SITE PLAN LEGEND
699 EXPOSITION BLVD. LOS ANGELES, CA 90089
ARCHITECT
MECHANICAL ENGINEER
ELECTRICAL ENGINEER
UNIVERSITY OF SOUTHERN CALIFORNIA CAPITAL CONSTRUCTION DEVELOPMENT
STUDIO +
CEDG
KSG ENGINEERS
3434 SOUTH GRAND AVENUE, CDF LOS ANGELES, CA 90089-3162
2070 BUSINESS CENTER DRIVE, SUITE 295 IRVINE, CA 92612
2725 WEST BURBANK BOULEVARD BURBANK, CA 91505
111 NORTH JACKSON STREET, SUITE 121 GLENDALE, CA 91206
P| 213-821-7900
P| 949-228-7528
P| 818-566-7755
P| 818-240-5630
CONTACT: PHIL BECKMAN
CONTACT: DANIEL SOLIS
CONTACT: JASON DONTJE, NCARB, LEED AP BD+C
ISSUE DATE 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016 04/12/2016
DRAWING INDEX 1. IT IS THE INTENT OF THE ARCHITECT THAT THIS WORK BE IN CONFORMANCE WITH THE BUILDING AUTHORITIES HAVING JURISDICTION OVER THIS WORK AND OCCUPANCY. ALL CONTRACTORS SHALL EXECUTE THEIR WORK IN COMPLIANCE WITH THE CODES LISTED HEREIN. ALL WORK SHALL BE EXECUTED UNDER PROPER BUILDING PERMITS AS REQUIRED BY THE AUTHORITIES HAVING JURISDICTION OVER THIS PROJECT.
ASPHALTIC CONCRETE ACOUSTICAL CEILING TILE ADJUSTABLE ABOVE FINISHED FLOOR ALUMINUM AT BY OWNER BOTTOM OF TUBE STEEL CLOSET CEILING CLEAR CONCRETE CORRIDOR CONCRETE MASONRY UNIT CONDENSING UNIT CONTINUOUS CONTROL JOINT CORNER GUARD COUNTERTOP DIAMETER DISPENSER DRAWINGS EXISTING ELECTRIC WATER COOLER ELEVATION ELECTRICAL EQUAL EQUIVALENT EXPANSION JOINT EXTERIOR FINISH FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FACE OF SHEATHING FACE OF WALL FIRE RETARDANT GRAB BAR GLASS GLASS MESH MORTAR UNITS GYPSUM BOARD HEIGHT HOLLOW METAL INSULATION INSTALLATION / PROCUREMENT JANITOR CLOSET
MAX MECH MIN MTD MT MTL MULL (N) NIC NTS OC O/C O/O PART PCC PL LAM PLYWD PTD POT REF REQ'D REV RTU RM RR SD SF SIM. STDS STL SUSP TEMP GL T/O TOTS TPD TW TYP UCR UL UNO W/ WD
4. CONTRACTOR SHALL USE ONLY THOSE ENTRANCES AND PARKING FACILITIES ASSIGNED BY THE BUILDING OWNER FOR SITE ACCESS. ALL MATERIAL DELIVERIES SHALL BE SCHEDULED SO AS TO MINIMIZE DISRUPTIONS TO THE BUILDING OCCUPANTS. 5. CLEANING: REMOVE RUBBISH, DEBRIS AND WORKERS FOOD ITEMS FROM THE JOB-SITE ON A DAILY BASIS. COMPLETED PROJECT SHALL BE HANDED OVER TO OWNER CLEAN, INCLUDING CLEANING OF ALL HARDWARE, FIXTURES AND GLASS, AND THE REMOVAL OF ANY AND ALL STAINS, DUST, DIRT AND PAINT. CLEAN AND POLISH ALL FINISHED FLOORS AND CABINETRY. 6. THE CONTRACTOR SHALL PREPARE A JOB-SITE LAYOUT ON THE FLOOR / GROUND (SHOWING ANY FIELD CONDITIONS THAT DEVIATE FROM THE CONSTRUCTION DOCUMENTS), FOR REVIEW BY THE ARCHITECT PRIOR TO COMMENCING SPECIFIC MODIFIED WORK. 7. THE CONTRACTOR SHALL FIELD MEASURE ALL DISTANCES AND CLEARANCES PRIOR TO COMMENCEMENT OF NEW WORK OR ORDERING OF MATERIALS. ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT PRIOR TO PROCEEDING WITH THAT PORTION OF WORK. THE CONTRACTOR SHALL NOT SCALE ANY DRAWINGS WITHIN THE CONSTRUCTION DOCUMENTS. ANY DISCREPANCIES SHALL BE RESOLVED BY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THAT WORK. 8. CONTRACTOR CLOSE-OUT DOCUMENTS: AT SUBSTANTIAL COMPLETION CONTRACTOR SHALL ASSEMBLE ORIGINAL COPIES OF ALL NEW EQUIPMENT/MATERIALS WARRANTIES AND OPERATIONAL LITERATURE. UPON ISSUANCE OF CERTIFICATE OF OCCUPANCY, THE CONTRACTOR SHALL PROVIDE TO THE OWNER, TWO COMPLETE SETS OF LEGIBLE RED- LINED AS-BUILT DRAWINGS (REFER TO DRAWING INDEX FOR LIST OF ALL SHEETS) SHOWING CONSTRUCTION, FIXED EQUIPMENT AND THE MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS AS INSTALLED. THESE DOCUMENTS SHALL BE DELIVERED TO THE OWNER IN A NEATLY INDEXED AND LABELED 3-RING BINDER. 9. WHERE REFERENCE IS MADE TO "BUILDING SYSTEMS", THIS SHALL INCLUDE ALL ELECTRICAL, PLUMBING, HVAC, TELEPHONE, AND FIRE ALARM/LIFE SAFETY COMPONENTS. 10. UNLESS SHOWN OTHERWISE, ALL DAMAGE CAUSED BY NEW WORK TO EXISTING AREAS OF THE SUITE, CONSTRUCTION, FINISH CONSTRUCTION, ELECTRICAL OR MECHANICAL SYSTEMS SHALL BE PATCHED / REPAIRED AND / OR CONSTRUCTED TO COMPLY WITH CURRENT GOVERNING CODES. 11. CHANGES TO THE APPROVED DRAWINGS AND SPECIFICATIONS SHALL BE MADE BY AN ADDENDA OR BULLETIN APPROVED BY THE CITY OF LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY (LADBS). 14. ALL WORK PERTAINING TO AND ALL MATERIALS SUPPLIED FOR EXECUTING AND COMPLETING THIS CONTRACT SHALL COMPLY WITH PROVISIONS SPECIFIED IN THE CONTRACT DOCUMENTS AND WITH ALL APPLICABLE LAWS, REGULATIONS AND ORDINANCES GOVERNING WORK INCLUDING, BUT NOT NECESSARILY LIMITED TO THOSE OF:
SECTION # SHEET DRAWN ON
SIM
1 A101
SECTION #
1
SHEET DRAWN ON
DETAIL CALLOUT
SIM
BUILDING SECTION CUT
A101
SECTION #
1
SHEET DRAWN ON
A101
1
SECTION # SHEET DRAWN ON
SIM
SIM
A101
WALL SECTION CUT
DETAIL SECTION CUT
GRID NUMBER
0
GRID BUBBLE
KEYNOTE NUMBER (SEE LEGEND ON SHEET)
00
DEMOLITION KEYNOTE
KEYNOTE NUMBER (SEE LEGEND ON SHEET)
00.01
NEW CONSTRUCTION KEYNOTE
DOOR NUMBER
116-1
AA
WINDOW CALLOUT
FINISH DESIGNATION
P1
FINISH TAG
1i
A1
LOCATION ON SHEET SHEET WHERE ELEVATION IS DRAWN
NAME ELEV. 0'-0"
A1
A4
A0.00
A2
W. 34
TH ST ./C HIL DS
WA Y
3
2
A-004
A-004
4 A-004
1
MUSICK LAW CENTER (LAW) 699 EXPOSITION BLVD. LOS ANGELES, CA 90089
SCOPE OF WORK:
SCOPE OF WORK TO INCLUDE, BUT NOT LIMITED TO DEMOLITION, NEW NON-BEARING METAL STUD WALL, POWER & DATA ALTERATIONS, NEW FINISHES
PROJECT AREA:
EXISTING BUILDING AREA: 152,402 SF SCOPE OF WORK AREA (1ST FLOOR): 1,702 SF
BUILDING INFO:
OCCUPANCY: (B) BUSINESS NUMBER OF STORIES: 4 CONSTRUCTION TYPE: II BUILDING IS FULLY SPRINKLERED
LEGAL DESCRIPTION:
APN: 5039024016 TRACT NO: TR12910
AHF
699 EXPOSITION BOULEVARD LOS ANGELES, CA 90089
PARTITION TAG CEILING HEIGHT - ABOVE FIN. FLR. ELEV. - 0'-0"
OFFICE AREA 110 ALTERATIONS W. 34
BUILDING / PAVING ELEVATION
ISSUED
WA Y
TGF
2014 CITY OF LOS ANGELES ELECTRICAL CODE PUBLISHED BY NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)) (BASED ON 2013 CALIFORNIA ELECTRICAL CODE (BASED ON 2011 NATIONAL ELECTRICAL CODE)) W/ L.A. CITY AMENDMENTS
VPD 5 A-004
2014 CITY OF LOS ANGELES MECHANICAL CODE PUBLISHED BY INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS (IAPMO)) (BASED ON 2013 CALIFORNIA MECHANICAL CODE (BASED ON 2012 UNIFORM MECHANICAL CODE)) W/ L.A. CITY AMENDMENTS 2014 CITY OF LOS ANGELES PLUMBING CODE PUBLISHED BY INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS (IAPMO) (BASED ON 2013 CALIFORNIA PLUMBING CODE (BASED ON 2012 UNIFORM PLUMBING CODE)) W/ L.A. CITY AMENDMENTS
TH ST ./C HIL DS
RGL
NORTH ARROW
SYMBOLS
2014 CITY OF LOS ANGELES GREEN BUILDING CODE PUBLISHED BY CALIFORNIA BUILDING STANDARDS COMMISSION (CBSC) (BASED ON 2013 CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 11 W/ L.A. CITY AMENDEMENTS W/ L.A. CITY AMENDMENTS
PROJECT ADDRESS:
MUSICK LAW CENTER (LAW)
TRUE NORTH
2014 CITY OF LOS ANGELES BUILDING CODE (BASED ON 2013 CALIFORNIA BUILDING CODE (BASED ON 2012 INTERNATIONAL BUILDING CODE)) W/ L.A. CITY AMENDMENTS
UNIVERSITY OF SOUTHERN CALIFORNIA CAPITAL CONSTRUCTION DEVELOPMENT 3434 SOUTH GRAND AVENUE, CDF LOS ANGELES, CA 90089-3162 P| 213-740-1638 F| 213-740-7411
A-004
INTERIOR ELEVATION CALLOUT PLAN NORTH
PROJECT OWNER:
PROJECT
JHH
LOCATION ON SHEET SHEET WHERE ELEVATION IS DRAWN
10'-0"
ELEVATION CALLOUT
A0.00
MUSICK LAW CENTER (LAW) OFFICE 110 ALTERATIONS
ADD ALTERNATE 1: CONTRACTOR SHALL PROVIDE A COST TO PROVIDE HANGER WIRES, SPLAY WIRES, ETC. TO MEET CURRENT CODE REQUIREMENTS IN OFFICE 110C. REFERENCE REMODEL REFLECTED CEILING PLAN
DOOR CALLOUT
WINDOW NUMBER
PROJECT NAME:
ADD ALTERNATES
ABBREVIATIONS
A3
CITY OF LOS ANGELES MUNICIPAL CODE CHAPTER IX BUILDING REGULATIONS
PROJECT INFO & SCOPE
MAXIMUM MECHANICAL MINIMUM MOUNTED MARBLE THRESHOLD METAL MULLION NEW NOT IN CONTRACT NOT TO SCALE ON CENTER OWNER FURNISHED / CONTRACTOR INSTALLED OWNER FURNISHED / OWNER INSTALLED PARTITION PORTLAND CEMENT CONCRETE PLASTIC LAMINATE PLYWOOD PAINTED PATH OF TRAVEL REFERENCE REQUIRED REVERSED ROOF TOP UNIT ROOM RESTROOM SOAP DISPENSER STOREFRONT SIMILAR STANDARDS STEEL SUSPENDED TEMPERED GLASS TOP OF TOP OF TUBE STEEL TOILET PAPER DISPENSER TREATED WOOD TYPICAL UNDER COUNTER REFRIGERATOR UNDERWRITER'S LABORATORIES UNLESS NOTED OTHERWISE WITH WOOD
2. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO NOTICE TO PROCEED AND SHALL DOCUMENT EXISTING CONDITIONS OF THE GENERAL PROJECT AREA. PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL VERIFY LOCATION OF ALL EQUIPMENT AND UTILITY POINTS OF SERVICE. 3. ALL BUILDING SYSTEM SERVICES (IE: WATER, SANITARY, FIRE ALARM, ELECTRIC, ETC.) SHALL REMAIN IN OPERATION THROUGHOUT CONSTRUCTION. ALL NECESSARY INTERRUPTIONS FOR CONNECTION OF NEW WORK SHALL BE PERFORMED AFTER NORMAL BUSINESS HOURS OR AS AGREED TO BY BUILDING OWNER. ANY REQUIRED INTERRUPTIONS OF SERVICE SHALL BE SCHEDULED AND APPROVED BY THE BUILDING OWNER 72 HOURS IN ADVANCE. COST IMPACTS OF AFTER HOURS WORK SHALL BE ANTICIPATED AND INCLUDED IN THE BID PROPOSAL.
PATH OF TRAVEL
WA Y
SHEET NAME COVER SHEET LADBS NOTES LADBS NOTES LADBS NOTES (E) ACCESSIBILITY DETAILS OVERALL FIRST FLOOR PLAN & ENLARGED (E) RESTROOM FLOOR PLAN ENLARGED FLOOR PLANS, CEILING PLANS, DETAILS DETAILS SPECIFICATIONS LEGENDS AND DETAIL PARTIAL FIRST FLOOR DEMOLITION NEW PLANS SPECIFICATIONS ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES ELECTRICAL CLOSEOUT SPECIFICATIONS IDENTIFICATION SPECIFICATIONS DEMOLITION POWER AND NEW POWER PLAN NEW POWER AND LIGHTING PLAN ELECTRICAL DETAIL SINGLE LINE DIAGRAM ENERGY COMPLIANCE FORMS ENERGY COMPLIANCE FORMS ENERGY COMPLIANCE FORMS
AC ACT ADJ AFF ALUM @ BO BOTS CLST CLG CLR CONC CORR CMU CONDEN CONT CJ CG CNTRTOP DIA DISP DWGS (E) EWC EL ELEC EQ EQUIV EJ EXT FIN FE FEC FOS FOW FR GB GL GMMU GYP BD HT HM INSUL INS / PRO JC
SCOPE OF WORK AREA
PA RD EE
SHEET NUMBER A-000 A-001 A-002 A-003 A-004 A-100 A-200 A-300 A-400 M000 M100 M800 E-000 E-001 E-002 E-100 E-200 E-500 E-700 E-800 E-801 E-802 Grand total: 22
BUILDING IN SCOPE OF WORK
OWNER
CONTACT: SHELLY WONG
(E) ITEM
HOH JKP
2014 CITY OF LOS ANGELES ELEVATOR CODE CHAPTER 9, ARTICLE 2 OF THE LOS ANGELES MUNICIPAL CODE PUBLISHED BY AMERICAN SOCIETY OF MECHANICAL ENGINEERS, BARCLAYS, AND BRACKETT (ASME) (BASED ON THE ASME A-17.1-1971 AND CALIFORNIA CODE OF REGULATIONS, TITLE 8, DIVISION 1, CHAPTER 4, SUBCHAPTER 6 WHICH INCORPORATED ASME A-17.1-1996 BY REFERENCE W/ L.A. CITY AMENDMENTS
MUSICK LAW CENTER (LAW)
USC PROJECT #
USC0001421
DATE
04/12/2016
DRAWN BY
FR
CHECKED BY
JD
PROJECT #
CA13600.05
TITLE
COVER SHEET
NATIONAL REFERENCE STANDARDS FOR STRUCTURAL DESIGN: ASCE 7-05 (MINIMUM STRUCTURAL DESIGN LOADS FOR BUILDING - GRAVITY, WIND, SNOW, SEISMIC) ACI 318-08 (CONCRETE) ACI 530-08 (MASONRY) AISC 360-05; 341-05; 358-05 (STEEL) 2006 NDS (WOOD) PARTIAL LIST OF APPLICABLE STANDARDS (NATIONAL FIRE PROTECTION ASSOCIATION CODE): 2014 CITY OF LOS ANGELES BUILDING CODE (FOR SFM) REFERENCED STANDARDS CHAPTER 35
LI J AS C
E
EN
SHEET #
APPLICABLE REQUIREMENTS OF SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT
VICINITY MAP
SITE PLAN
1 1" = 50'-0"
A-000
7
. 07- 3 1- 1 R OF CA L I F O
NI
A
TE
A
NO. C-32176
2007 EDITION 2006 EDITION 2008 EDITION
GENERAL PROJECT NOTES
TJ
W EXPOSITION BLVD
T
ENTRANCE 2
PROJECT SITE MUSICK LAW CENTER (LAW)
EC
2010 EDITION 2007 EDITION 2002 EDITION 2002 EDITION 2007 EDITION 2010 EDITION 2010 EDITION
R
NFPA 80 NFPA 253 NFPA 2001
AUTOMATIC SPRINKLER SYSTEMS (CALIFORNIA AMENDED) STANDPIPE SYSTEMS (CALIFORNIA AMENDED) DRY CHEMICAL EXTINGUISHING SYSTEMS WET CHEMICAL EXTINGUISHING SYSTEMS STATIONARY PIPES PRIVATE FIRE SERVICE MAINS (CALIFORNIA AMENDED) NATIONAL FIRE ALARM CODE (CALIFORNIA AMENDED) (NOTE: SEE UL STANDARD 1971 FOR "VISUAL DEVICES") FIRE DOOR AND OTHER OPENING PROTECTIVES CRITICAL RADIANT FLUX OF FLOOR COVERING SYSTEMS CLEAN AGENT FIRE EXTINGUISHING SYSTEMS
ST
NFPA 13 NFPA 14 NFPA 17 NFPA 17A NFPA 20 NFPA 24 NFPA 72
A S E D RC H EN A . D I T ON ON
(E) 2" WARNING STRIPE AT STAIR NOSING (TYP)
7
(E) SLOPED WALKWAY UP 5% MAX SLOPE (E)
12" (E) MIN + TREAD DEPTH
6' - 0" (E) LANDING @ 2% MAX SLOPE EA WAY
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.315.1993
(E) HANDRAIL @ 34" - 38"A.F.F. (TYP)
A-004 TYP
UP
(E) 2" WARNING STRIPE AT STAIR NOSING (TYP)
12" (E) MIN
12' - 0" (E) LANDING @ 2% MAX SLOPE EA WAY
6' - 0" (E) LANDING @ 2% MAX SLOPE EA WAY
FOR STAIR NOSING DETAIL -REF 7/A-004
(E) PLANTER WALL
A-004 TYP
FOR STAIR NOSING DETAIL -REF 7/A-004
6' - 0" (E) LANDING @ 2% MAX SLOPE EA WAY
NOT USED
23
NOT USED
N.T.S.
NOT USED
22
18
NOT USED
N.T.S.
NOT USED
N.T.S.
17
UP
12" (E) MIN
7
13
12" (E) MIN + TREAD DEPTH
(E) SLOPED WALKWAY UP 5% MAX SLOPE (E)
(E) ENLARGED STAIR PLAN
N.T.S.
NOT USED
N.T.S.
12
5 1/8" = 1'-0"
NOT USED
N.T.S.
9
(E) ACCESSIBLE PARKING SIGNAGE
N.T.S.
4 3/4" = 1'-0"
PROJECT
NOT USED
21
NOT USED
N.T.S.
16
NOT USED
N.T.S.
11 N.T.S.
(E) HANDRAIL NON-CIRCULAR CROSS SECTION
8
(E) TYPICAL PARKING STRIPING
1/4" = 1'-0"
MUSICK LAW CENTER (LAW)
3 1/8" = 1'-0"
699 EXPOSITION BOULEVARD LOS ANGELES, CA 90089
OFFICE AREA 110 ALTERATIONS ISSUED
NOT USED
20
NOT USED
N.T.S.
15 N.T.S.
NOT USED
10
(E) HANDRAIL EXTENSION DETAILS
7
(E) ACCESSIBLE VAN PARKING
1/2" = 1'-0"
N.T.S.
2
USC PROJECT #
USC0001421
DATE
04/12/2016
DRAWN BY
FR
CHECKED BY
JD
PROJECT #
CA13600.05
1/8" = 1'-0"
TITLE
(E) ACCESSIBILITY DETAILS
EC
LI J AS C
A S E D RCH EN A . D I T ON ON
T
TJ E
EN
A
SHEET #
NOT USED
19 N.T.S.
NOT USED
14 N.T.S.
(E) STAIR NOSING DETAILS
6 1" = 1'-0"
(E) ACCESSIBLE PARKING
1 1/8" = 1'-0"
A-004
7
. 07- 3 1- 1 R OF CA L I F O
NI
R
ST
TE
A
NO. C-32176
NOTE: PROVIDE MIN. 30" x 48" CLEAR FLOOR SPACE IN FRONT OF ACCESSORY TO ALLOW FORWARD OR PARALLEL APPROACH. HIGHEST OPERABLE PART AT MAX 3' - 4" AFF
SAN. NAPKIN DISPOSAL & TISSUE DISPENSER
TOILET TISSUE DISPENSER
12" MAX 42" MIN
30" MIN CLR
12".
17" MAX
24" MIN
44" MAX
FOF
14" MIN 17" MAX
24".
17" MIN 19" MAX
17" MIN 18" MAX
33".
CL
CL
URINAL SCREEN WHERE OCCURS
EQ EQ
54" MIN
36" MIN C 12". L 24". MIN MIN
B
(E) WATER CLOSET
C
(E) SOAP DISPENSER
D
(E) PAPER TOWEL DISPENSER/ WASTE RECEPTACLE
MIRROR / SOAP DISPENSER
NOTES: 1. FLUSH VALVE TO BE LOCATED TO THE WIDE SIDE 2. REF FRAMING DETAILS FOR GRAB BAR BACKING 6" MAX
(E) LAV
(E) TOILET TISSUE DISPENSER
F
(E) TOILET TISSUE DISPENSER/ FEMININE NAPKIN DISPPOSAL
G
(E) MIRROR
H
(E) GRAB BAR
I
(E) TOILET SEAT COVER DISPENSER
J
(E) URINAL
(E) DRINKING FOUNTAIN
NOTE: DRAIN AND HOT WATER PIPING SHALL BE INSULATED AND THERE SHALL BE NO SHARP OR ABRASIVE ELEMENTS UNDER LAVATORY
F
VEST 108
17" MIN 19" MAX
8". MIN
17" MIN 19" MAX
H
FOR (E) RESTROOM SIGNAGE -REF 3 A-100
4 A-100
VEST 111
B
48" MIN (E)
H
CORRIDOR 60" DIA CLR E
I
6". MAX
60" MIN (E)
MENS ROOM 111A
TOP OF CONTROL / SWITCH / OUTLET
30"x48" CLR
30"x48" CLR
60" DIA CLR
G
C
A
D
34" MAX
46" MAX SIDE APPROACH 44" MAX FRONT APPROACH
40" MAX
48" MAX
TOP OF CONTROL/ SWITCH / OUTLET
SAN. NAP. DISPOSAL / ST CVR DISPENSER
6
18" MIN (E)
1/4" = 1'-0"
2' - 0" MAX
TEL CLOSET 18" MIN (E) 111B
FF FF CONTROL / SWITCH / CONTROL / SWITCH / OUTLET OUTLET HEIGHT, TYP HEIGHT OVER OBSTRUCTION
NOT USED
I
LAVATORY
SANITARY NAPKIN DISPOSAL
SEAT COVER DISPENSER
EXIT PATH
WOMENS ROOM 108A
J NOTE: HIGHEST OPERABLE PART AT MAX 3' - 4" AFF
(N) ITEM
D
60" DIA CLR
G
60" DIA CLR
KNEE CLEARANCE
PAPER TOWEL DISPENSER / HAND DRYER
C
H
9" MIN CLR
27" MIN
CLR
29" MIN
34" MAX
40" MAX
4
17" MIN
HAND DRYER
NOTE: PROVIDE BLOCKOUT FOR FIXTURE WHERE CONCRETE CURB OCCURS
60" MIN (E)
FOR (E) RESTROOM FIXTURE & ACCESSORY MOUNTING -REF 5 A-100
ACCESSIBLE
18" MIN
A
B
URINAL
NOTE: PROVIDE MIN. 30" x 48" CLEAR FLOOR SPACE IN FRONT OF ACCESSORY TO ALLOW FORWARD OR PARALLEL APPROACH. HIGHEST OPERABLE PART AT MAX. 3' - 4" AFF
30"x48" CLR
H
ACCESSIBLE
ACCESSIBLE TOILET / GRAB BARS
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.315.1993
OVERALL FLOOR PLAN LEGEND
E
17-1/2". STANDARD
18" MIN (E)
(E) ITEM
TO VALVE
TISSUE DISPENSER
A
48" MIN (E)
19".
19".
18" MIN (E) 40" MAX
7" - 9"
7" - 9"
TO REFLECTIVE SURFACE
NOTE: ACCESSORIES SHALL BE FULLY RECESSED OR SEMI-RECESSED WITH A MAX 3" PROJECTION
18" MIN (E)
CONTROLS, SWITCHES & OUTLETS
5
(E) RR FIXTURE & ACCESSORY MOUNTING
N.T.S.
(E) RESTROOM SIGNAGE
3
ENLARGED (E) RESTROOM FLOOR PLAN
1/4" = 1'-0"
1/2" = 1'-0"
2 1/4" = 1'-0"
FOR CONTINUATON OF PATH OF TRAVEL -REF 1 A-000
PROJECT
OFFICE 124A
OFFICE 124B
OFFICE 124C
OFFICE 122A SEMINAR ROOM 120
CLASSROOM 130
OFFICE 110
OFFICE 121
VEST 107D
JAN 125A
STORAGE 127 MENS ROOM 125
WOMENS ROOM 129C CLASSROOM 103
CLASSROOM 101 LOBBY
STORAGE 129B ELEVATOR E1B
PROJ. RM 107A
TRIAL COURT 107
OFFICE 109A
LOBBY
OM VEST 129A
OFFICE 100E
VEST 107C
OFFICE 100A
OFFICE 100D OFFICE 100B
OFFICE 100C
VEST 108
OFFICE AREA 110 ALTERATIONS
CONF 110E
ISSUED
VEST 111 WORK RM OFFICE 110G 110F
MENS ROOM 111A
TEL CLOSET 111B 2 A-100
VEST 129
SEMI 106
CLASSRM 107B STAIRS S1E
OFFICE 104A
OFFICE 104G
OFFICE 104
STAIRS S1C STORAGE 100G
WOMENS ROOM 108A
ELEV LOBBY E1I
CORRIDOR
OFFICE 100
ELEV E1A
699 EXPOSITION BOULEVARD LOS ANGELES, CA 90089
WORKROOM 104F
STAIRS S1D
OFFICE 105
OFFICE 105A OFFICE 104B
OFFICE 104C
OFFICE 104D
OFFICE 105B
OFFICE 105C
OFFICE 105D
USC PROJECT #
USC0001421
DATE
04/12/2016
DRAWN BY
JD
CHECKED BY
JD
PROJECT #
CA13600.05
TITLE
OVERALL FIRST FLOOR PLAN & ENLARGED (E) RESTROOM FLOOR PLAN
OFFICE 104E
A S E D RCH EN A . D I T ON ON
EC T
TJ E
NO. C-32176 EN
R
ST
A
TE
. 07- 3 1- 1 R OF CA L I F O
SHEET #
OVERALL FIRST FLOOR PLAN
1 3/32" = 1'-0"
A-100
A
Room 110J
MUSICK LAW CENTER (LAW)
OFFICE 110C
LI J AS C
STORAGE 132
CORRIDOR
3 A-200
7
PATH OF TRAVEL = 167' - 0"
1 A-200
NI
OFFICE 122
INTERVIEW 128
STAIRS S1B
SEMINAR ROOM 114 OFFICE 110B
OFFICE 124
UP
SEMINAR ROOM 118
OFFICE 110A
STAIRS S1A
STAIRS
UP
STAIRS S1F
REMODEL RCP LEGEND
PAINT P1
MANUFACTURER: DUNN-EDWARDS 1ST & 2ND COAT: ULTRASHIELD INTERIOR COLOR: DEW 385 LIGHTHOUSE FINISH: EGGSHELL (ES) INSTALLATION: FIELD PAINT
DEMOLITION RCP PLAN LEGEND
OFFICE 110B TYP 09.01
(E) ITEM
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.315.1993
(N) ITEM
KEYNOTE LEGEND
DEMO / REMOVE ITEM
OFFICE 110C
ACOUSTICAL CEILING TILE
MANUFACTURER: DUNN EDWARDS 1ST COAT: ULTRASHIELD INTERIOR 2ND & 3RD COATS: ULTRASHIELD INTERIOR COLOR: MATCH (E) DOOR FRAMES FINISH: SEMI-GLOSS INSTALLATION: DOOR FRAMES
TYP (N) ACOUSTICAL CEILING TILE
ACOUSTICAL CEILING TILE
OFFICE 110
26.01
OFFICE 110
00.04 DEMO / REMOVE ACOUSTICAL CEILING TILE
LIGHT FIXTURES
MANUFACTURER: BURKE TYPE: COVED RUBBER BASE, TS COLOR: 674 CARMINE GRAY HEIGHT: 4" FIRE CLASS: N/A FLAME SPREAD: N/A SMOKE DENSITY: N/A VOC: CERTIFIED LOW EMISSIONS
NUMBER PROVIDE ITEM / WORK 00.01 REMOVE DOOR & FRAME - SALVAGE DOOR & HARDWARE AND DOOR PLAQUE - TURN OVER TO OWNER 00.02 REMOVE OFFICE FURNITURE / EQUIPMENT & REINSTALL AT PROJECT COMPLETION 00.03 DEMO WALL-MOUNTED SHELVING & PLYWD BACKING 00.04 REMOVE ACOUSTICAL CEILING TILE & PROTECT FOR REINSTALLATION 00.05 DEMO CEILING SUSPENSION SYSTEM GRID MEMBER 00.06 DEMO 2X4 LIGHT FIXTURE 00.08 DEMO OFFICE FURNITURE 00.09 DEMO CARPET AT NEW WALL AS REQ'D PER REMODEL PLAN 08.01 FIXED WINDOW - US ALUMINUM 487 SERIES W/ 1/4" CLEAR GLAZING - MATCH FINISH OF (E) WINDOWS IN SUITE 09.01 INSTALL CEILING SUSPENSION SYSTEM GRID MEMBERS & WALL ANGLES AS REQ'D TO ENCLOSE ROOM (12/A-300) 09.02 REINSTALL SALVAGED ACOUSTICAL CEILING TILE 09.04 PATCH AND REPAIR GYP BD & FINISH AS REQ'D TO MATCH (E) 10.02 TACTILE EXIT SIGN (6/A-200) 12.01 REINSTALL OFFICE FURNITURE / EQUIPMENT AT PROJECT COMPLETION 26.01 2x4 LIGHT FIXTURE (REF ELEC)
00.05 TYP
09.02 08.01
COVE BASE CB1
00.06
26.01
MANUFACTURER: DUNN-EDWARDS 1ST & 2ND COATS: ULTRASHIELD INTERIOR COLOR: TO BE DETERMINED FROM MFR'S STANDARD RANGE OF COLORS FINISH: EGGSHELL (ES) INSTALLATION: ACCENT WALLS
P3
00.04
(E) ITEM
(N) ITEM P2
OFFICE 110B
00.05 TYP
09.01 TYP LIGHT FIXTURES
09.02 TYP
HVAC SUPPLY/RETURN
(E) LIGHT FIXTURE ADD ALTERNATE 1: CONTRACTOR SHALL PROVIDE A COST TO PROVIDE HANGER WIRES, SPLAY WIRES, ETC. TO MEET CURRENT CODE REQUIREMENTS IN OFFICE 110C. -REF 12
(E) LIGHT FIXTURE
HVAC SUPPLY/RETURN
CONF 110C
CONF 110E
A-300
4
1ST FLOOR RCP - REMODEL
9
INTERIOR FINISHES
1ST FLOOR RCP - DEMOLITION
1/4" = 1'-0"
12" = 1'-0"
FLOOR PLAN LEGEND
REMODEL FLOOR PLAN NOTES
(E) ITEM (N) ITEM 2/10" SPACE BETWEEN CELLS (LETTERS) CALIFORNIA GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED INDIVIDUAL BRAILLE DOTS SHALL EACH BE DISTINCT AND BE ROUNDED OR DOMED IN LIEU OF SQUARE SIDED AND FLAT TOPPED.
1/4" = 1'-0"
DEMOLITION FLOOR PLAN LEGEND
1. PROTECT IN PLACE (E) FIRE - LIFE SAFETY DEVICES. MODIFY FIRE ALARM SYSTEM AS REQUIRED PER REMODEL PLAN. FIRE ALARM MODIFICATIONS SHALL BE DESIGNED, PERMITTED, AND CONSTRUCTED BY AN APPROPRIATELY LICENSED FIRE ALARM CONTRACTOR. 2. PATCH & REPAIR (E)PLASTER & DRYWALL FINISH AS REQ'D TO PROVIDE A CONSISTENT & UNIFORM WALL FINISH THROUGHOUT AREA OF WORK. ALL ROOMS WITHIN THE AREA OF WORK SHALL RECEIVE NEW WALL PAINT. 3. FIRE SPRINKLER MODIFICATIONS SHALL BE DESIGNED, PERMITTED, AND CONSTRUCTED BY AN APPROPRIATELY LICENSED FIRE-SPRINKLER CONTRACTOR. 4. ALL WALLS WITHIN SUITE SHALL RECEIVE NEW PAINT UNO P1 5. REFERENCE 'INTERIOR FINISHES' FOR FINISH INFO 6. PROVIDE CB1 AT ALL NEW WALLS 7. ALL CEILINGS ARE LOCATED AT 10'-0" A.F.F.
AREA OF WORK
2
DEMOLITION FLOOR PLAN NOTES 1. ALL OFFICE FURNITURE WITHIN SUITE SHALL BE MOVED / REMOVED BY THE CONTRACTOR FOR PAINTING AND THEN RE-INSTALLED ONCE PAINTING IS COMPLETE.
AREA OF WORK (E) ITEM REMOVE / DEMO (E) ITEM
1/10" BY 1/10" GRID
BRAILLE SPACING TEMPLATE
00.02
8
CHARACTER & BRAILLE STANDARDS
3" = 1'-0"
OFFICE 110A
12.01
OFFICE 110A
00.02 12.01 TEXT & BRAILLE SYMBOLS -REF 8
TEXT 11B-703.2.4 PROPORTIONS. VISUAL CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER "I". STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 10 PERCENT MINIMUM AND 15 PERCENT MAX OF THE HEIGHT OF THE CHARACTER.
A-200 P2 FINISH: CHARACTERS, SYMBOLS, PICTOGRAMS AND THEIR BACKGROUNDS SHALL HAVE A NONGLARE FINISH, SUCH AS MATTE, SATIN OR EGGSHELL.
00.02
09.04
00.02
12.01
CONTRAST: CHARACTERS, SYMBOLS AND PICTOGRAMS SHALL CONTRAST WITH THEIR BACKGROUND, EITHER LIGHT CHARACTERS, SYMBOLS AND PICTOGRAMS ON A DARK BACKGROUND OR DARK CHARACTERS, SYMBOLS AND PICTOGRAMS ON A LIGHT BACKGROUND. A CONTRAST BETWEEN THE COLOR OF THE BACKGROUND AND THE COLOR OF THE CHARACTERS, SYMBOLS AND PICTOGRAMS OF AT LEAST 70% BASED ON THE LIGHT REFLECTANCE VALUE IS A RECOMMENDED. A CONTRAST BETWEEN THE BACKGROUND COLOR OF THE DOOR MOUNTED TOILET ROOM SIGN AND THE COLOR OF THE DOOR OF AT LEAST 70% BASED ON THE LIGHT REFLECTANCE VALUE IS RECOMMENDED.
09.04
OFFICE 110B
12.01
OFFICE 110B
12.01
P2
ALIGN
OFFICE 110
7
SIGNAGE NOTES
00.03 00.02
110C-A
P2
BRAILLE SYMBOLS: CALIFORNIA CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE SYMBOLS ARE REQUIRED BY EITHER THE CALIFORNIA BUILDING CODE OR THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES. BRAILLE SHALL BE LOCATED A MINIMUM OF 1/2" FROM TACTILE CHARACTERS. BRAILLE DOTS SHALL BE 1/10" ON CENTERS IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS. BRAILLE DOTS SHALL BE RAISED 1/40" MINIMUM ABOVE THE BACKGROUND. BRAILLE DOTS TO HAVE DOMED TOPS.
PROJECT
A-200
P2
OFFICE 110
OFFICE 110C
5
3" = 1'-0" 1A
00.09
699 EXPOSITION BOULEVARD LOS ANGELES, CA 90089
OFFICE AREA 110 ALTERATIONS ISSUED
CONTRACTED GRADE 2 BRAILLE, RAISED 1/40" MIN, TO BE LOCATED DIRECTLY UNDER OR ADJACENT TO EXIT INFORMATION
12.01
10.02
PROVIDE BACKING @ 18" O.C. VERTICAL ALONG ENTIRE LENGTH OF WALL BETWEEN 2' - 0" A.F.F. AND 6' - 6" A.F.F
EXIT ROUTE SIGN
1A
ALIGN 00.08 00.02
P2
CONF 110E
NOTES: 1. SIGN MATERIAL SHALL BE 1/8" THICK ACRYLIC PLASTIC WITH 1/32" RAISED BORDER, GRAPHIC, AND LETTERS. PROVIDE MECHANICAL MOUNTING WITH VANDAL RESISTANT FASTENERS. COMPLY WITH ARTICLE 4.30 & A4.30 OF ADAAG. 2. SEE FLOOR PLANS FOR LOCATION 3. FOR ADDITIONAL INFO, REF 8 7 A-200
00.09
MUSICK LAW CENTER (LAW)
00.01
A
EXIT ROUTE
00.03
CONF 110C
A-200 COLOR & FINISH LEGEND: (A) CONTRASTING COLOR 1 (B) CONTRASTING COLOR 2 P2
6
TACTILE EXIT SIGNAGE
3" = 1'-0"
04/12/2016
DRAWN BY
JD
CHECKED BY
JD
PROJECT #
CA13600.05
TITLE
OFFICE 110D
WORK RM 110G
DATE
ENLARGED FLOOR PLANS, CEILING PLANS, DETAILS
HEIGHT
WORK ROOM 110E
LI J AS C
A S E D RC H EN A . D I T ON ON
TJ
T
MATCH (E)
08.01
2' - 0" +/MATCH (E)
4' - 4" +/MATCH (E)
USC0001421
EC
E
EN
R
ST
A
TE
. 07- 3 1- 1 R OF CA L I F O
SHEET #
INTERIOR ELEVATION
5 1/4" = 1'-0"
1ST FLOOR PLAN - REMODEL
3 1/4" = 1'-0"
1ST FLOOR PLAN - DEMOLITION
1 1/4" = 1'-0"
A-200
A
NO. C-32176 7
10' - 0" +/- (E)
4"
P2
(E) CEILING
OFFICE 110F
USC PROJECT #
NI
60" MAX AFF 48" MIN AFF 3/8"
B
00.08
MTL. PL-8 x 3 x 16 GA. w/ (2) #12 SMS 16" OC (TYP)
DOOR SCHEDULE Mark 110C-A
Width
Fire Rating
Height
3' - 0"
7' - 0"
Frame Type
NR
A
Frame Material HM
Door Material SCWD
Panic Hardware
Door Finish FF
No
Hardware Set Door Head 1
Door Jamb
Door Threshold
LESSER OF 8" MAX 0.25 x LENGTH OF END RUNNER
Remarks
0.145" DIA RAMSET 1500 SERIES SHOT PINS (LARR 22668) - EMBED 1 1/2" AT CONC FOAM BACKER ROD
22 / A-300 22 / A-300 N/A HANGER WIRE
DOOR ABBREVIATIONS
DOOR TYPE
REF DOOR SCHED
16 GA MTL STUD (TYP)
FRAME TYPE
JAMB SECTION
REF DOOR SCHED
MTL. STUD PER FLOOR PLAN
2
#12 SMS 16" OC (TYP)
3
MTL. PL-8 x 3 x 16 GA
4
XXXT150-16 GA
5
XXXS162-16 GA
6
600S162-16 GA
7
400S162-16 GA
2070 Business Center Drive, Suite 295, Irvine, California 92612 | P: 949.315.1993
MAIN RUNNER OR CROSS TEE 1/2" MIN
2"
2"
FF FACTORY FINISH HM HOLLOW METAL SCWD SOLID CORE WOOD
A
SEALANT
14 A-300
1
(E) CONC STRUCTURE
3 TIGHT TURNS WITHIN 1 1/2" ACOUSTIC CEILING TILE
1
1
2
2
MODEL TA2714 NRP 4-1/2” x 4-1/2” ML2055 LWA CT6 403
FINISH MATCH (E) MATCH (E) MATCH (E)
MANUFACTURER MCKINNEY CORBIN RUSSWIN ROCKWOOD MFG
3"
A-300
3
DO NOT FASTEN GYP BD TO TRACK (TYP)
5 W = 0' TO 4'-0"
ALUM POP RIVET
NOTES A
C
HEADER SECTIONS
A
FLUSH SWINGING DOOR
W = 4'-1" TO 8'-0"
B
WALL P3
4
MTL STUD PER WALL TYPE
WALL ANGLE ATTACHED W/ #6 SMS 32" OC
MTL STUD NOTE: "XXX" REFERENCES STUD DEPTH, REF WALL TYPES
20
DOOR SCHEDULE
15
T-BAR CEILING PERIMETER - FIXED
1/4" = 1'-0"
10
TOP OF WALL ASSEMBLY
3" = 1'-0"
3" = 1'-0"
1 1/2" = 1'-0" 1" (TYP)
BRACING WIRE 1" WIDE X 12 GA STL STRAP
MTL STUDS SOUND ATTENUATION INSULATION MTL STUD TRACK -REF 2
12 GA HANGER WIRE MIN (4) PER FIXTURE
(E) MTL DECK
12 GA HANGER WIRE 4'-0" OC MAX (TYP)
3/8" Ø HILTI KB-TZ EXP ANCHOR W/ 2" MIN EMBED (LARR 25701)
A-300 MTL STUD TRACK ATTACHMENT -REF 8
AT BRACING WIRE
A-300 0.145" DIA SHOT PIN W/ 1" MIN EMBED (LARR 25646)
WALL BASE
METAL STUD (E) CONC FLOOR STRUCT
T-BAR CEILING GRID (E) MTL DECK
1.
INSTALLATION: SURROUND EACH PANEL WITH A MAIN RUNNER, CROSS RUNNER, OR LEDGER ANGLE.
2.
COMPONENTS: SYSTEM SHALL SUPPORT NO OTHER COMPONENTS EXCEPT GRILLES OR LIGHT FIXTURES.
2 - #8 SMS EA SIDE TO MAIN RUNNER OR PROVIDE SEISMIC HOLD DOWN CLIPS CAPABLE OF RESISTING ANY DIRECTIONAL FORCE EQUAL TO FIXTURE WEIGHT
23
3.
HANGER WIRES: MINIMUM 12 GAGE, MAXIMUM 16 SF. NO SPLICES PERMITTED.
4.
PERIMETERS: HANGER WIRE WITHIN 8 INCHES OF SUPPORT OR WITHIN 1/3 OF LENGTH OF END TEE, WHICHEVER IS LESS.
5.
ATTACH SYSTEM TO NOT MORE THAN 2 ADJACENT WALLS; LEAVE 1/2" FREE OF OTHER WALLS.
6.
PROVIDE STRUTS OR 16 GAGE WIRE TO CONNECT FREE END OF CROSS RUNNERS MORE THAN 12 INCHES FROM WALL.
NTS
8.
DISTANCE OF SPLAYED BRACING FROM WALL: MAXIMUM 4 FEET.
9.
SLOPE OF BRACING WIRES: 45 DEGREES FROM PLANE OF CEILING. MAINTAIN WIRES TIGHT; NO SPLICES PERMITTED.
10. THREE TIGHT TURNS REQUIRED AT HANGER WIRE; 4 TIGHT TURNS AT BRACING WIRES, ALL WITHIN 1-1/2". ALIGN WIRES IN DIRECTION OF PULL.
4'0" TY P 12 GA HANGER WIRE
14 A-300
W
1"
A-300 3 TIGHT TURNS WITHIN 1 1/2"
2".
45
CROSS TEE
16 A-300
MTL STUD NOTE "XXX" REFERENCES STUD DEPTH, REF WALL TYPES
MIN
8
WALL TO FLR & PIPE PENETRATION
1 1/2" = 1'-0"
WALL FINISH (TYP.)
FOR MTL TRACK SPLICE REF 3
WALL FINISH (TYP.)
13'-0" MAX
A
45
ACOUSTIC CLG TILE
T-INTERSECTION - PLAN
C
MTL. STUD (TYP.)
INTERSECTION - PLAN
3" = 1'-0"
A-300 18 A-300
B
D
END - PLAN
8" MAX. @ JAMB (TYP.) CORNER - PLAN
17
SUSPENDED T-BAR CEILING
3" = 1'-0"
FASTENER (TYP) BASE TRACK XXXT150 - 20 GA -REF 8
A-300
MTL STUD NOTE 1. "XXX" REFERENCES STUD DEPTH, REF WALL TYPES 2. ALL MTL STUDS SHALL BE PER ICC-ESR 3016
12
MTL STUD WALL DETAILS
3" = 1'-0"
7
USC PROJECT #
USC0001421
DATE
04/12/2016
DRAWN BY
FR
CHECKED BY
JD
PROJECT #
CA13600.05
A-300
MTL STUD WALL FRAMING
1" = 1'-0"
2 1/4" = 1'-0"
(E) HEADER BOTTOM TRACK
10 A-300
LESSER OF 8" MAX 0.25 x LENGTH OF END RUNNER (3) #12 SMS METAL STRUT 1/2" MIN
HANGER WIRE
MTL STUD
14 A-300
A-300
DETAILS
CEILING WHERE OCCURS
6" x 16 GA STL PL (2) #12 SMS (TYP)
HORIZ 6" RINGSHANK NAIL
5/8" GYP BD EA. SIDE
MAIN RUNNER OR CROSS TEE
5/8" GYP. BD ON EACH SIDE OF INFILL WALL PROVIDE ACOUSTICAL INSULATION FULL WIDTH OF WALL AT (N) FRAMING
CONTINUE GYP BD TO STRUCTURE ABOVE
5A
2"
METAL STUD WALL FRAMING @ 16" O.C. TO MATCH EXISTING WALL WIDTH
TITLE
(E) STRUCTURE ABOVE METAL STUD
3 TIGHT TURNS WITHIN 1 1/2" 2"
(2) #12 SMS (TYP)
ACOUSTIC CLG TILE
3-5/8" MTL STUD @ 16" OC MAX 362S162 - 20 GA (ICC-ESR 3016) SOUND ATTENUATION INSUL
CUT PART OF TRACK & BEND DOWN
A S E D RC H EN A . D I T ON ON
NOTE: DETAIL IS SIMILAR FOR SILL CONDITION
A-300
SEALANT BOTH SIDES
E
PLAN
TE
A
ELEVATION
WALL
(E) FINISHED FLOOR
EN
R
TRIM ANGLE ATTACHED W/ #6 SMS 32" OC
NO. C-32176
FOR ADDITIONAL FRAMING INFORMATION -REF 2
ST
#8 SMS @ ALL STUD TO RUNNER CONNECTIONS (TYP)
TJ
9 A-300
A-300
. 07- 3 1- 1 R OF CA L I F O
SHEET #
WALL INFILL
21 1/2" = 1'-0"
T-BAR CEILING PERIMETER - SLIP JOINT
16 3" = 1'-0"
MTL STUD BACKING
11 1 1/2" = 1'-0"
MTL STUD LINTEL CONNECTION
6 1/2" = 1'-0"
WALL TYPE 1A
1 1" = 1'-0"
T
FIRESTOPPING AT OPENINGS, VOIDS, & PENETRATIONS
EC
MTL STUD BASE TRACK -REF 2
A-300
A
(N) 16 GA. TRACK W/ 2 ROWS OF #10 S.M.S. @ 24" O.C. (STAGGERED) (E) DOOR JAMB FRAMING
7' - 0" +/VIF
METAL STUD BACKING -REF 11
SECTION A
4" +/VIF
A
MTL STUD LINTEL CONNECTION -REF 6 A-300
14' - 0"
NOTE: MTL STUDS SHALL BE PER ICC-ESR 1464 3' -
A-300 METAL STUD 16" OC MAX, XXXS162 - 20 GA -REF 7
2. FOR ADDITIONAL NOTES A-300
HANGER WIRE TO CEILING GRID
ISSUED
METAL STUD OPENING FRAMING -REF 5
OPENING PER PLAN
DOUBLE MTL. STUDS
17 A-300
NOTES: 19 1. FOR GRILLE / DIFFUSER AND LIGHT FIXTURE A-300 ATTACHMENT
OFFICE AREA 110 ALTERATIONS
NOTE: BRIDGING CHANNEL NOT REQ'D WHERE GYP BD IS INSTALLED BOTH SIDES
13
22
13'-0" MAX.
A-300
699 EXPOSITION BOULEVARD LOS ANGELES, CA 90089
SLOTTED TRACK XXXSLT250 - 20 GA -REF 4 A-300
METAL STUD (TYP.)
MUSICK LAW CENTER (LAW)
3 1/2" = 1'-0"
FROM BRACING WIRES TO COMP POST & X-RUNNER
NOTE: FRAME DEPTH TO BE DETERMINED BY OVERALL WALL THICKNESS
DOOR HEAD / JAMB
BOTTOM TRACK SPLICE DETAIL
MTL STUD TRACK SPLICE
17 A-300
MAIN RUNNER (TYP)
ANCHORS PER MANUFACTURER'S RECOMMENDATIONS @ 30" OC MAX & WITHIN 6" FROM EA END / CORNER
CONC SLAB EXTRA ANCHOR
7
FRAME DEPTH
15 A-300
MA 2" X 2 MA " X
1/2"
2"
#8 SMS EA. LEG
14 A-300
12 GA HANGER WIRES 4'-0" OC EA WAY W/ (3) TIGHT TURNS IN 1 1/2" BOTH ENDS (TYP)
S
MTL STUD MTL STUD TRACK
(E) CONC FLOOR
MAX
2"
MAIN RUNNER HOLLOW METAL DOOR FRAME
45
6"
BASE TRACK
17 CROSS RUNNER A-300 (TYP)
P TY 0" 4'-
FOR HEADER / JAMB FRAMING - REF 2
45
XXXS125-20 GA x 16" LONG
MAX.MAX.
PIPE/CONDUIT PENETRATION
(E) COMPRESSION STRUT WHERE OCCURS
E
GYP BD
0.145" DIA RAMSET 1500 SERIES SHOT PINS @ 16" OC MAX (LARR 22668) - EMBED 1 1/2"
6"
TOP TRACK SPLICE DETAIL
6" = 1'-0"
REF WALL TYPE
2"
13
12 GA BRACING WIRE W/ (4) TIGHT TURNS IN 1 1/2" BOTH ENDS TYP
PROJECT
CUT OPENING
13. SUSPENSION SYSTEM: HEAVY DUTY
N
6" EXTRA ANCHOR
1" MAX. TYP.
MTL STUD PER WALL TYPE
12. LIGHT FIXTURES: ATTACH TO CEILING SYSTEM TO RESIST HORIZONTAL FORCE EQUAL TO WEIGHT OF FIXTURE.
SUSPENDED T-BAR CEILING NOTES
6"
PIPE/CONDUIT
MTL STUD WHERE OCCURS
11. SEPARATE WIRES 6 INCHES FROM UNBRACED DUCTS, PIPES OR CONDUIT. CONDUIT 3/4" DIAMETER OR LESS MAY BE ATTACHED TO WIRES USING APPROVED CONNECTORS.
1 1/2" = 1'-0"
MTL STUD FRAMING
BASE TRACK
XXXS125-20 GA x 16" LONG
SPLAYED BRACING: SETS OF FOUR, 12 GAGE MINIMUM, MAXIMUM SPACING OF 12 x 8 FEET. PROVIDE VERTICAL COMPRESSION STRUT AT EACH SET OF BRACING WIRES.
18
LIGHT FIXTURE AT T-BAR CLG
3" = 1'-0" SLOTTED TRACK (TYP)
SUSPENSION SYSTEM
1. ATTACH ALL LIGHT FIXTURES TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES 2. SUPPORT SURFACE MOUNTED LIGHT FIXTURES BY AT LEAST TWO POSITIVE DEVICES WHICH SURROUND THE CEILING RUNNER AND WHICH ARE EACH SUPPORTED FROM THE STRUCTURE ABOVE BY A 12 GA WIRE - SPRING CLIPS OR CLAMPS THAT CONNECT ONLY TO THE RUNNER ARE NOT ACCEPTABLE 3. SUPPORT PENDANT MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRUCTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE FIXTURE - SPECIAL DETAILS ARE NECESSARY FOR THIS CONDITION AT THE CEILING GRID
4
SLOTTED MTL TRACK
3" = 1'-0"
1" MIN. TYP.
WIRE HANGER PLACED ON DIAGONAL CORNERS (2) EXCEPT 4'x4' FIXTURES SHALL HAVE HANGERS AT EACH CORNER (4 TOTAL)
9
WALL BASE
3" = 1'-0"
7.
1/2"
14
HANGER WIRE TO METAL DECK
1 1/2" = 1'-0" LIGHT FIXTURE (56 LBS MAX)
NOT USED
/2" 11
1.25".
NTS
/2" 21
AT HANGER WIRE
HANGER WIRE
19
" 1/2
SEALANT & BACKER ROD
13 GA x 3/4" CEILING CLIP
MECH DIFFUSER AT T-BAR CLG
" 1/2
FLOOR FINISH
(E) CONC FILL
ACOUSTIC TILE CEILING PANEL
24
#8 x 9/16" LONG WAFER HEAD SCREW ON BOTH SIDES F RE ALL W PE TY
3 TIGHT TURNS IN 1 1/2" (TYP)
NOT USED
SLOTTED TRACK ICC ESR1042
GYP BD
(E) CONC FILL
PREFAB DIFFUSER (REF MECH)
5
MTL STUD OPENING FRAMING
NI
DOOR FRAME FINISH SHALL BE
4
LI J AS C
DEVICE (3) HINGE (1) CLASSROOM LOCKSET (1) WALL STOP
16 GA SLOTTED TRACK -REF
1/2" GAP
HARDWARE SET 1
REF DOOR SCHED
DOOR HARDWARE SET
REF DOOR SCHED
4