14 ADDING SOCIAL FUNCTIONS FOR PEOPLE/
13
SOCIAL VALUES / VỀ GIÁ TRỊ XÃ HÔI ADDING ENVIRONMENTAL VALUES/
ADDING ECONOMIC VALUES/
FOCUSING ON SUSTAINABLE ENVIRONMENT
VỀ GIÁ TRỊ XÃ HÔI, THIẾT KẾ NÀY SẼ TẠO RA MỘT KHÔNG GIAN CÔNG CỘNG THÂN THIỆN VỚI NGƯỜI SỬ DỤNG, PHỤC VỤ CHO NHIỀU ĐỐI TƯỢNG (CẢ NGƯỜI TÀN TẬT, TRẺ EM). NGOÀI GIÁ TRỊ THÔNG THƯỜNG NHƯ MỘT BẾN XE BUÝT, THIẾT KẾ TẠO CẢM GIÁC CỦA MỘT KHÔNG GIAN XANH THU NHỎ, GIÚP NGƯỜI SỬ DỤNG CẢM THẤY THOẢI MÁI, KHUYẾN KHÍCH VIỆC GIAO TIẾP, KẾT NỐI TRONG CỘNG ĐỒNG. VỚI KHÔNG GIAN XANH, MÀU SẮC ĐA DẠNG, HỆ THỐNG GHẾ NGỒI THÔNG MÌNH, THIẾT KẾ SẼ GÓP PHẦN GIA TĂNG KHÔNG GIAN XÃ HỘI (VỐN RẤT THIẾU HỤT) CHO CÁC ĐÔ THỊ Ở VIỆT NAM. NÓ CŨNG THỂ HIỆN SỰ QUAN TÂM, TÔN TRỌNG DÀNH CHO CÁC ĐỐI TƯỢNG KHÁC NHAU TRONG XÃ HỘI, NHƯ NGƯỜI TÀN TẬT (KHU VỰC DÀNH RIÊNG CHO NGƯỜI TÀN TẬT), TRẺ EM (THIẾT KẾ GHẾ NGỒI THÂN THIỆN, MÀU SẮC SẶC SỠ).
17
12
15 16
4 2
10
3
10
1
11
5
IMRPOVING NATURAL VENTILATION
7 REDUCING CO2 LEVEL
6 DEVELOPING WATER SAVING SYSTEM
7 8
ENVIRONEMTAL STRATEGY VỀ GIÁ TRỊ MÔI TRƯỜNG, THIẾT KẾ NÀY SẼ GÓP PHẦN ĐÁNG KỂ CẢI THIỆN TÌNH TRẠNG THIẾU KHÔNG GIAN XANH CÔNG CỘNG Ở HÀ NỘI VÀ CÁC ĐÔ THỊ LỚN Ở VIÊT NAM VỚI CÂY XANH VÀ HỆ THỐNG NỀN KHÔNG HOÀN TOÀN BỊ BÊ TÔNG HÓA. NGOÀI MỘT CÂY LỚN, MẢNG TƯỜNG PHÍA SAU ĐƯỢC THIỆT KẾ NHƯ GIÁ TRỒNG CÂY THEO MÔ HÌNH MỘT VƯỜN TREO THU NHỎ. THIẾT KẾ GÓP PHẦN GIA TĂNG SỐ LƯỢNG CÂY, TẠO KHÔNG GIAN SỐNG TRONG LÀNH HƠN CHO ĐÔ THỊ.
9
CURTAIN WALL SYSTEM TO FACADE ENG'S DETAIL
3D MODEL INDICATIVE ONLY
50MM TRAFFICABLE BONDOR EQUIDECK PANELS WITH CAPPING PIECES AT 2 DEGREE FALL. COLOUR TO MATCH PA-33. STRUCTURAL STEEL PAINT FINISHED
Z PROFILE PAINT FINISH PA-33 COLOUR PA-33
FIN TO STRUCTURAL ENGINEER DETAIL
STRUCTURAL BEAM IN LINE WITH UCHANNEL & EQUAL ANGLES SEE RCP
GENERAL NOTES
SECONDARY STEEL FRAME TO SUPPORT CEILING.
1. THIS DRAWING TO BE READ INCONJUNCTION WITH BUT NOT LIMITED TO STRUCTURAL, MECHANICAL, HYDRAULIC, ELEC., BCA, ACCESS & FIRE CONSULTANTS DRAWINGS AND SPECS. 2. ALL PENETRATIONS / FIXING TO MAIN STRUCTURES MUST BE APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION ON SITE. 3. FOR STEEL SIZINGS AND FIXINGS REFER TO STRUC. ENG. DOCUMENTS. 4. REFER TO PLAN SHEETS FOR DIMENSIONS AND GRID REFS. 5. STRUCTURAL STEEL SHOWN RED FOR CLARITY.
REMOVABLE PLASTERBOARD CEILING MECHANICALLY FIXED TO SUBFRAME.
STEELWORK LEGEND NOTES 1
PAINTED PLASTERBOARD LINING ON INTERIOR
2 S.S. HAND / BUMPRAIL - BH-10
3 4 5
VERTICAL STRUCTURAL MEMBERS. PAINT FINISH. PA-33
6 7
TIMBER SKIRTING S.S. BUMPRAIL - BH-10
8 9
TILED FLOOR ON BONDEK SLAB
CLOUDS
SOLID CLOUD- CHANGE SINCE LAST REVISION. DASHED CLOUD- AREA UNDER REVIEW.
FOR FINISHES SCHEDULE REFER TO C5 ATO 4102 - EXTERNAL FINISHES SCHEDULE REFER TO SHEET AD058000000 FOR MISC. METALWORK LEGEND.
SERVICE ZONE UNDER (LEVEL 1 BRIDGE ONLY) SURROUND IN COMPOSITE ALUMINIUM - FA-03 INSULATED INFILL PANEL. CLAD WITH COMPOSITE PANEL BOTH SIDES. FA-03.
BRIDGE NOTES
FIXED GLAZING PANEL - GL-01
REMOVABLE COMPOSITE ALUMINIUM CEILING SOFFIT PANELS WITH EXPRESSED JOINTS. COLOUR FA-03
FIXED ALUMINIUM LOUVRES WITH INSECT MESH. POWDER COATED TO MATCH. COMPOSITE PANELS. LO-10
3
L01 BRIDGE -PART OF T2 FIRE COMPARTMENT L04 BRIDGE -PART OF PODIUM CARPARK FIRE COMP. L09 BRIDGE (OPEN) -PART OF T2 FIRE COMP.
STRUCTURAL AXO- L01 BRIDGE SCALE
BONDOR TO BE PIR CORE (NON-FLAMMABLE). STRUCTURAL STEEL SHOWN IN RED. PORTAL FRAME SHOWN IN BLUE.
STEEL PROFILE PAINT FINISH PA-33 STEEL TO BE PRE-PAINTED: LAST COAT TO BE APPLIED ON SITE.
1
MANUFACTURER TO ALLOW FOR TOLERANCES & CLEARANCES. DIMENSIONS ON THIS DRAWINGS ARE NORMINAL DESIGN PANEL SIZES ONLY. PROVIDE SHOP DRAWINGS PRIOR TO MANUFACTURE. SHOP DRAWINGS TO SHOW ALL DIMENSIONS & FIXING DETAILS. TENDERERS TO PROVIDE A SCHEDULE OF PANELS. ALL FIXINGS, BRACKETS, PLATES ETC; TO BE HOT DIPPED GALVANISED, UNLESS NOTICED OTHERWISE. ALL DIMENSIONS TO BE CHECKED ON SITE. FIGURED DIMENSIONS ONLY TO BE USED. REFER TO ALL ARCH. & DETAIL DRAWINGS, STRUCTURAL, MECHANICAL AND SERVICE DRAWINGS BEFORE COMMENCING WORK. REFER ANY DISCREPANCIES TO THE ARCHITECTS. MANUFACTURER TO CARRY OUT ON-SITE DIMENSIONS CHECKS FOR ALL PANEL DESIGNS. PROVIDE SAMPLE TEST PANELS FOR APPROVAL AND SUBSEQUENT CONTROL CHECKING.
DRAWING TO BE READ IN COLOUR
L01 BRIDGE ISOMETRIC INTENT STEEL "PORTAL FRAME" INFILL PIECE. PROVIDES FLUSH CONNECTION POINT BETWEEN BRIDGE STEEL AND CURTAIN WALL GLAZING SYSTEM.
VERTICAL FIN STRUCTURAL MEMBERS. PAINT FINISH.
HAND / BUMPRAIL COMPOSITE PANEL LINING S.S. BUMPRAIL 50MM BUILDING MOVEMENT ZONE. BRASS LATHAM RIGID FLOOR EXPANSION JOINT AT FLOOR. PORTAL FRAME 50MM BUILDING MOVEMENT ZONE (CONCEALED BY FACADE ELEMENTS)
CURTAIN WALL SYSTEM TO FACADE ENG'S DETAIL FIXED ALUMINIUM LOUVRES WITH INSECT MESH. POWDERCOATED TO MATCH. COMPOSITE PANELS. LO-10
STEEL PROFILE PAINT FINISH STEEL TO BE PRE-PAINTED: LAST COAT TO BE APPLIED ON SITE.
FIXTURES & FINISHES LEGEND 1921 LV-BR
2
ARCHITECTURAL AXO- L01 BRIDGE SCALE
6
ARCHITECTURAL AXO- L01 BRIDGE AT T1 SCALE
INSULATED OPAQUE PANEL LINED WITH PREFINISHED ALUMINIUM COMPOSITE SHEET BOTH SIDES LOUVRE BRIDGES
PA-04A TL-02
TL-02
PA05A/B
SYMBOLS
TL-02
DISTRIBUTION BOARD ONT
TL-02 SK-01
COMMS
GENERAL NOTES
SINGLE SWITCHED SOCKET OUTLET (GPO)
1. FOR TYPICAL WALL DETAILS - REFER TO DRAWINGS AD851000001 TO AD51000006.
DOUBLE SWITCHED SOCKET OUTLET (GPO) SINGLE LIGHTING SWITCH TL-02
DOUBLE LIGHTING SWITCH ONE WAY LOCAL DIMMER LIGHTING SWITCH
TL-02
DATA / TELEPHONE OUTLET TELEVISION OUTLET / ANTENNA
PA-04A
EXHAUST AIR DUCT LED RECESSED DOWNLIGHT LED WALL MOUNTED BALCONY LIGHT RECESSED SPRINKLER SP
EXPOSED SPRINKLER
A/C
AIR CONDITIONER CEILING SPEAKER
P A
TA NL
163010001
TB
7200 STRIP DRAIN NORTH 2
3675 STRIP DRAIN NORTH 6
GL-07A
PA-04A
PA-01C ABOVE
MR-02
OY C A B R IG R P T H
CEILING TO PREFABRICATED 'POD' TO SEPERATE PACKAGE
GL-07A
SINGLE LINEAR LIGHTING
TL-02
OY C A B R IG R P T H
2555RL
THERMAL INSULATION 50mm THICK KINGSPAN KOOLTHERM K10-F SOFFIT BOARD (R-VALUE = 3.0)
PA-04A
TA-12
PA-01C ABOVE
MR-02
GL-07A
2555RL
DOUBLE LINEAR LIGHTING SK-01
OY C A B R IG R P T H
AMENITIES (WOMEN)
SK-01
REFER TO AD162010077
MJ
FFL 2.570
MJ
SK-01
2
TL-01
FW
220 BORDER
HERE BORDER ALIGN TO ADJACENT TILE
2555RL
2555RL SPA
NOT USED
220 BORDER
TL-02
MJ
HERE BORDER 150MM OFFSET ADJACENT TILES
2555RL
2505RL
REFER TO AD162010075 FOR POOL TILE SETOUT & DESIGN
2555RL
DIRECT STICK TL-04A TO TOP TO POOL SHELL/SPA WALL (IE. LOWER THAN POOL BORDER)
2555RL
HERE BORDER ALIGN TO ADJACENT TILE ROW
NOTE DIFFERENT BORDER WIDTH. DUE TO 300MM CAULK, WIDER BORDER TILE TO AVOID CUTTING 80MM SLITHER
2555RL
2545RL
MJ
2545RL
TILE SET-OUT POINT
TL-01
TL-02
2555RL
MJ
MJ MJ
2545RL
2545RL
TL-02
GL-07A
TL-02
GL-07A
2555RL
FW TL-02
TL-02
FALL
TL-02
FW TL-02
FALL
TL-02
FW FALL
7
FALL
FALL
2555RL
2555RL
2555RL
SK-01
PA-04A SK-01 FA-05A
FA-05A 3750
1676 TSO
FA-05A
FA-05A 1100
FA-05A 7200
FA-05A 1100
9601 26993 STRIP DRAIN SOUTH
PA-02A
FA-05A
FA-05A 1600
4359
SK-01
SECURITY CONTROL PANEL INTERCOM STATION
RELOCATED INTERCOM STATION-AWAITING SUB-CONT. DRAWING TO BE UPDATED MI MATER VIDEO INTERCOM ENTRANCE STATION X2 - ONE AT DDA HEIGHT MASTER INTERCOM CONTROL PANEL
ABBREVIATIONS
SK-01
( REFER TO THE FINISHES & FF&E SCHEDULE FOR DETAILS ) FIXTURES & FINISHES LEGEND GL-07A MR-02 PA-02A PA-04A SK-01 ST-01
SKIRTING SK-01 DETAIL REFER 01/857500001 BELOW
6
PA-04A MJ
REED SWITCH FOR ROLLER SHUTER
DOME CCTV CAMERA
TL-02 FW
APARTMENT / LOBBY
SOUNDER
I
5
FALL
FALL
MJ
FALL
MJ
380
2555RL
FALL
220
2555RL
FALL
FALL
MJ
660
MJ
MJ
CAULK JOINT
2555RL
4
2555RL
FALL
0.0000
CCTV
FW
2545RL
HERE BORDER USE SETOUT DIM BRD. TSO
ALL POOL ROOM STRIP DRAINS - AQUABOCCI A30 120MM (W) X 35MM (H) WITH THE OPTIONAL NON SLIP FINISH. PRE MADE MITRE CORNERS. COLOUR CHAMPAGNE.
HERE BORDER ALIGN TO NEXT TILE ROW BORDER
BRD. TSO
380 505 TSO
HERE BORDER USE SETOUT DIM
FALL
FALL
220 CAULK JOINT
BUILDING
BREAK GLASS FOR DOOR RELEASE
SCP
2555RL
FALL
LEVEL
SECURITY DURESS BUTTON
MJ
2545RL
NAMING CONVENTION
I
2540RL (EQUAL TO LIFT THRESHOLD)
220 BORDER
400 CAULK JOINT FALL
TL-01
MJ
16. WHERE AN ELEMENT HAS BEEN NOTED TO ALIGN WITH ANOTHER ELEMENT BUT DOES NOT DUE TO CONSTRUCTION TOLERANCE, ARCHITECT IS TO BE CONTACTED FOR AN INSTRUCTION.
KEYPAD
S
MICP
2555RL
HERE BORDER 150MM OFFSET ADJACENT TILES
TL-10 40MM CONTRASTING STRIPS ON EDGE OF SPA SEAT
2555RL
FW
TL-02
15. SERVICE LOCATIONS ARE INDICATIVE AND SUBJECT TO CONFIRMATION BY SERVICES CONTRACTOR
CARD READER
BG
ST-01
PA-04A
2545RL
TL-02
FW
660 CAULK JOINT
40MM CONTRASTING STRIPS ON STAIRS. USE TILE TL-10
TL-02
14. REFER ARCHITECTURAL DESIGN SPECIFICATION "PARTITIONS AND CEILINGS" - DOCUMENT NO. C5-AS0-2620
ELECTRIC STRIKE
K
ST-02
FALL FALL
HD
3
1693 STRIP DRAIN NORTH 5
FALL
FALL
300
300
CAULK JOINT
MJ
13. DOOR FRAMES ARE TO BE SETOUT 100MM FROM WALL ON HINGED SIDE OR CENTERED ON THE ROOM OR CORRIDOR UNLESS NOTED OTHERWISE.
EGRESS BUTTON
TR-01
FALL
2545RL
12. PROVIDE BOXED STUDS TO ALL DOOR FRAMES & WHERE STUD WALLS STOP WITHOUT RETURN WALLS. PACK ADJACENT STUDS AS NECESSARY TO MAINTAIN PLUMB LININGS.
REED SWITCH
MJ
2555RL
FW
2545RL
2505RL
RS
2555RL
2545RL
2505RL
2555RL
MJ
2555RL
FALL
FALL
SK-01
MJ
2555RL
220 BORDER
MJ
TL-02
TL-01
2555RL 220 BORDER
MJ
MOTION DETECTOR
ES
SK-01
MJ
220 CAULK JOINT
TL-02 TL-02
MJ
FW
EXIT SIGN WITH ARROW
RS
TL-02
FALL
MJ
TL-02
NO FALLS - FLAT
FALL
SK-01
10. ACOUSTIC LAGGING REQUIRED TO ALL HYDRAULIC PIPEWORK IN HYDRAULIC RISERS ADJACENT HABITABLE ROOMS.
CEILING SLOT 800 X 250 (MAKE UP AIR)
6810
TL-02
FALL
FW 220 CAULK JOINT
TL-02
FALL
2545RL
TL-02
2545RL
2555RL
FALL
FALL
FALL
2545RL
MJ
STRIP DRAIN WEST
SK-01
FW
2545RL
FALL
FALL
TL-01
TL-02
MJ
2555RL
TL-02
2555RL
HERE BORDER ALIGN TO NEXT TILE ROW
2555RL
FW
TL-02
FALL
TL-02
2555RL
FALL
FALL
FALL
FALL
2555RL
FALL
TL-02
EXIT
M.
PA-04A
2545RL
FALL
5
6810
SK-01
FW
NOT USED FALL
1693
STRIP DRAIN NORTH 3
2545RL
FW 2555RL
MJ
TL-02 FALL
SK-01
FALL
MJ
2555RL FALL
FALL
2545RL
2555RL
MJ
PA-04A
REFER TO AD162010077
NO FALLS - FLAT
1.0075 D001
MJ
DT D617
4
REFER TO AD163010001
FALL
1.0080 D001
2555RL
EXIT SIGN
FALL
CF-01
REFER TO AD163010001
220 CAULK JOINT
1.0076 D001
NO FALLS - FLAT
220 BORDER
HOIST ROOM
FALL
PUMP ROOM
1.0079 D001
TL-02 ABOVE
2555RL
PA-04A
FW-06
EXIT
2555RL
BORDER
FW-06
2
GL-07A
2555RL TL-02
6
RECESSED EMERGENCY LUMINAIRE TL-01
TL-01
1.0071 D001
EMERGENCY DOUBLE LINEAR LIGHTING
2555RL
STRIP DRAIN EAST
MJ
TL-02
OY C A B R IG R P T H
AMENITIES (MEN)
NH PB
3
EMERGENCY SINGLE LINEAR LIGHTING
PA-04A
2718 STRIP DRAIN NORTH 1
7. REFER TO THE ELECTRICAL ENGINEER'S DOCUMENTATION FOR ALL ELECTRICAL REQUIREMENTS AND HIGH LEVEL ELECTRICAL EQUIPMENT SHOWN ON REFLECTED CEILING PLANS.
WALL TYPE (REFER TYPICAL WALL DETAILS - 11. PROVIDE SUFFICIENT FRAMING WITHIN STUD WALLS DWG NO.S AD51000001 - AD51000005) FOR ALL FIXTURES, FITTINGS, EQUIPMENT & JOINERY.
00
NM NN
6. REFLECTED CEILING PLANS TO BE READ IN CONJUNCTION WITH ALL SERVICE DRAWINGS. ALLOW FOR ALL CEILING MOUNTED SPRINKLERS, LIGHT FITTINGS, ACCESS PANELS & LINEAR GRILLES TO BULKHEADS.
9. SQARE SET TO ALL LIVING, DINING, KITCHEN, BEDROOM AND HALL CEILING PERIMETERS. RONDO P26 STOPPING ANGLE TO ALL INSITU BATHROOMS.
PERMANENT POWER CONNECTION
1
5. PLANS & REFLECTED CEILING PLANS TO BE READ IN CONJUNCTION WITH THE ACOUSTIC SPECIFICATION BY RENZO TONIN ASSOCIATES.
CEILING ACCESS PANEL MECHANICAL TUNDISH
NK
4. FOR FINISHES SCHEDULE AND FF&E FOR APARTMENT GRADE INCLUSIONS AND COLOUR SCHEME SELECTIONS REFER TO SCHEDULE AT-04003
8. PROVIDE PAINTED FINGER JOINTED PINE SKIRTING THROUGHOUT (EXCLUDING WET AREAS).
TL-01
NJ
3. FOR KITCHEN AND JOINERY DETAILS - REFER TO DRAWINGS AD863000000 SERIES
SMOKE DETECTOR PA-04A SK-01
2. FOR TYPICAL POD (PREFABRICATED BATHROOM) DETAILS REFER TO DRAWINGS AD863500001 SERIES
7
SHOPFRONT GLASS Single Glazed MIRRORED WALL CLADDING AS SCHEDULED PAINT FINISH AS SCHEDULED POLISHED PLASTER FINISH- CUSTOM COPPER LEAF SKIRTING ALUMINIUM AS SCHEDULED (ALUMINIUM WHITE) STONE 01 AS SCHEDULED
FIXTURES & FINISHES LEGEND TL-01 TL-02 TR-01
TILES 300X600 (PORCELAIN) AS SCHEDULED TILES 1200X600 AS SCHEDULED ALUMINIUM ENTRY REVEAL (POWDERCOASTED BLACK) AS SCHEDULED
SYMBOLS DISTRIBUTION BOARD COMMS
ONT LEGEND- SCREENS SHEETLIST
01. BOURKE STREET FACADE (EXTERIOR) AD162010070 PLAN AD167000007 PLAN/ELEVATION 02. LINKWAY FACADE (EXTERIOR) AD167000008 PLAN/SECTION AD167000111 03. L00 PODIUM LOBBY/POOL (INTERIOR) AD161010011 LOBBY PLAN AD167000012 PLAN/ELEVATION 04. L00 TOWER 2 LOBBY (INTERIOR) AD361000001 PLAN AD361000002 ELEVATIONS 05. L09 PODIUM LOBBY (INTERIOR) AD261010920 PLAN/ELEVATION SCHEDULE AD580000220 AD580000221 CONSTRUCTION SUMMARY
TYPICAL SET-OUT LEGEND
SINGLE SWITCHED SOCKET OUTLET (GPO)
( REFER TO DWG HEIGHT PRINCIPLE -AD030500001 FOR FURTHER DETAIL)
DOUBLE SWITCHED SOCKET OUTLET (GPO) SINGLE LIGHTING SWITCH
SET-OUT TYPE A
Ai
DOUBLE LIGHTING SWITCH SET-OUT TYPE AII
Aii
ONE WAY LOCAL DIMMER LIGHTING SWITCH DATA / TELEPHONE OUTLET
SET-OUT SWIPE CARD 400
INTERCOM PILLAR (WHEN APPLICABLE). COMPOSITE PANEL BACK AND FRONT. COLOUR TO MATCH GLAZING MULLIONS.
300
SC
1200 CONCRETE PAVER PV-01
STONE ST-01/ST-02/ST-03/ST-04
DOOR FRAME / EDGE OF WALL
LED RECESSED DOWNLIGHT
INTERCOM ( IF APPLICABLE) SWIPE CARD
LED WALL MOUNTED BALCONY LIGHT RECESSED SPRINKLER EXPOSED SPRINKLER
A/C
AIR CONDITIONER CEILING SPEAKER SMOKE DETECTOR
INTERCOM
RUBBER RM-01/RM-02
NJ
TILE TL-01/TL-02/TL-03/TL-04/TL-05/TL-06 TIMBER TB-01/TB-02/TB-03
SP
SWIIPE CARD PLATE
SC
CONCRETE CF-01/CF-02/CF-03/CF-04/CF-05/CF-06/CF-07
EXHAUST AIR DUCT
ALLOW FOR 200mm OFFSET TO CENTRELINE OF SWITCH PLATE FROM EDGE OF WALLWHERE APPLICABLE
200
FLOOR FINISHES CARPET CP-01/CP-02/CP-03/CP-04
TELEVISION OUTLET / ANTENNA
NK
TACTILES TI-01
TA NL
TB
P
NO
NM NN
CEILING ACCESS PANEL
A
MECHANICAL TUNDISH
1
4
2
163010001
861000020
861000022
11
7
861000020
861000021
T1
1.0078 GLAZED WALL
BL-19S FR-0
W35
6
OY C A B R IG R P T H
DT D660
OY C A B R IG R P T H
SC
163010003
CORRIDOR
STORE
OY C A B R IG R P T H
BL-19S FR-0
+4550FFL
CEILING TO PREFABRICATED 'POD' TO SEPERATE PACKAGE
LIBRARY
1.0025
SINGLE LINEAR LIGHTING
SC
W36
1.0071
1.0078 DT D619
1.0073 D001
OY C A B R IG R P T H
NH PB
W35
W35
861000020
W36
THERMAL INSULATION 50mm THICK KINGSPAN KOOLTHERM K10-F SOFFIT BOARD (R-VALUE = 3.0)
GYM W35
WALL MOUNTED- DOUBLE LINEAR LIGHTING EMERGENCY SINGLE LINEAR LIGHTING
CORRIDOR
1.0077 W31
FFL 2.570 W36
CORRIDOR
DOUBLE LINEAR LIGHTING DT D620
W23
1.0073
W36
W36
BL-19S FR-0 CF - 2000
EMERGENCY DOUBLE LINEAR LIGHTING RECESSED EMERGENCY LUMINAIRE
1.0074 162010073
4
15275
2
990000101
W33
1.0071 D001
BL-19S FR-0
1435
W36 W36
163010003
10
FW-06
FW-06
PUMP ROOM
BL-19F FR-120
1.0079
1435
BL-19S FR-0
W31
AMENITIES (MEN)
HOIST ROOM
1.0076 D001
1.0080 SSL 2.572
1.0076
53
1.0072
AMENITIES (WOMEN) FW-05
FW-05
1.0075
FFL 2.570
FFL 2.500
53
7
162010078
5
EXIT
EXIT SIGN WITH ARROW MOTION DETECTOR CEILING SLOT 800 X 250 (MAKE UP AIR)
Ai 6
RS
990000101
3
W31
RS VESTIBULE
53
W31
EXIT SIGN
BL-19S FR-0
BL-19S FR-0
53
EXIT
M.
FFL 2.570 1.0075 D001
1.0080 D001
1.0079 D001
2
3
OVER 4 GLAZING
BUILDING MANAGER OFFICE
W36
BL-19S FR-0
SSL 2.570
8
W36
REED SWITCH HD
ES
1.0021861000021
EGRESS BUTTON
5
1.0070 D617
1435
BL-19S FR-0
W31
W36
10
FW-05
1
2
ALIGN
550
550
1528
RECESSED S.S. ROPE HOOK (TYP. CENTRED AT EACH END)
1.0070
162010074
4
1
3 861000002
1 162010072
RECESSED S.S. ROPE HOOK (TYP. CENTRED AT EACH END)
5
161010021
6
4
1528
6
550
U1 FW-05
FW-05
581
CLEANING ZONE
FFL 2.570 SSL 2.500
550
5 861000011
5
CLEANING ZONE
1200
5
1200
FW-05
CLEANING ZONE
1200
5
1200
5
1200
5
1200
5
1200
5
1200
5
7
CLEANING ZONE
W41 1200
5
1200
1200
5
5
1200
5
1200
5
1200
5
1200
5
1200
5
1200
5
1200
5
1200
5
1200
5
1200
5
653
247
SIM
6 861000011
NH PB
5
RELOCATED TO ALIGN WITH OTHER SERVICES
FW-05
W41 1200
1.0020
800 U1
U1
200
1542
W25
800
200
550
5
161010016
NJ
NK
SCREEN 03. L00 PODIUM LOBBY/POOL (INTERIOR)
TA NL
CONTINUED ON DRAWING No. AD161010011 161010017
2
MASTER INTERCOM CONTROL PANEL
ABBREVIATIONS
LOBBY 550
RELOCATED INTERCOM STATION- SUBCONTRACTORS DRAWING TO BE UPDATED MI MATER VIDEO INTERCOM ENTRANCE STATION X2 - ONE AT DDA HEIGHT
DOME CCTV CAMERA
7
861000002
TB
8. PROVIDE PAINTED FINGER JOINTED PINE SKIRTING THROUGHOUT (EXCLUDING WET AREAS). 9. SQARE SET TO ALL LIVING, DINING, KITCHEN, BEDROOM AND HALL CEILING PERIMETERS. RONDO P26 STOPPING ANGLE TO ALL INSITU BATHROOMS. 10. ACOUSTIC LAGGING REQUIRED TO ALL HYDRAULIC PIPEWORK IN HYDRAULIC RISERS ADJACENT HABITABLE ROOMS. 11. PROVIDE SUFFICIENT FRAMING WITHIN STUD WALLS FOR ALL FIXTURES, FITTINGS, EQUIPMENT & JOINERY. 12. PROVIDE BOXED STUDS TO ALL DOOR FRAMES & WHERE STUD WALLS STOP WITHOUT RETURN WALLS. PACK ADJACENT STUDS AS NECESSARY TO MAINTAIN PLUMB LININGS. 13. DOOR FRAMES ARE TO BE SETOUT 100MM FROM WALL ON HINGED SIDE OR CENTERED ON THE ROOM OR CORRIDOR UNLESS NOTED OTHERWISE. 14. REFER ARCHITECTURAL DESIGN SPECIFICATION "PARTITIONS AND CEILINGS" - DOCUMENT NO. C5-AS0-2620 15. SERVICE LOCATIONS ARE INDICATIVE AND SUBJECT TO CONFIRMATION BY SERVICES CONTRACTOR 16. WHERE AN ELEMENT HAS BEEN NOTED TO ALIGN WITH ANOTHER ELEMENT BUT DOES NOT DUE TO CONSTRUCTION TOLERANCE, ARCHITECT IS TO BE CONTACTED FOR AN INSTRUCTION. NAMING CONVENTION
LEVEL
NM NN
NO
0.0000
APARTMENT / LOBBY
FIXTURES & FINISHES LEGEND
INTERCOM STATION
CCTV
W31
11
2
7. REFER TO THE ELECTRICAL ENGINEER'S DOCUMENTATION FOR ALL ELECTRICAL REQUIREMENTS AND HIGH LEVEL ELECTRICAL EQUIPMENT SHOWN ON REFLECTED CEILING PLANS.
SECURITY CONTROL PANEL I
MICP
3
5. PLANS & REFLECTED CEILING PLANS TO BE READ IN CONJUNCTION WITH THE ACOUSTIC SPECIFICATION BY RENZO TONIN ASSOCIATES.
SOUNDER
SCP
861000021
5
FW-05 4
BREAK GLASS FOR DOOR RELEASE
I
1
MOSAICS REMOVED FROM POOL EDGE
861000002
7
9 DT D622
162010075
POOL
4. FOR FINISHES SCHEDULE AND FF&E FOR APARTMENT GRADE INCLUSIONS AND COLOUR SCHEME SELECTIONS REFER TO SCHEDULE AT-04003
BUILDING
FW-05
795
162010075
1
6
FW-05
UP S.S. HANDRAIL BH-01
6
RETURN AIR LOUVRE TO FACE OF COLUMN CLADDING WITH MECHANICAL DUCTWORK IN WALL CAVITY (TYP.). REFER ELEVS. COLOUR TO MATCH TILES.
861000002
FW-05
550
U1 UPLIGHTS MOUNTED AT BASE OF COLUMNS (TYP.)
3
162010075
3. FOR KITCHEN AND JOINERY DETAILS - REFER TO DRAWINGS AD863000000 SERIES
SECURITY DURESS BUTTON
TB-01
SPA
KEYPAD
BG
U1
550
NOTE: IN AREAS WITH TIMBER DECKING FLOOR WASTES ARE BELOW FLOOR (TYP).
1532
LINKWAY SCREEN 02. LINKWAY FACADE (EXTERIOR)
4
U1
861000021
200
U1
K
1
FW-05
861000002
200
200
2066
FW-05
CARD READER
S
W31
200
5
8
6
SC
U1
TB-01
167000102
162010027
7
ALIGN
300
69
1
U1
200
U1
861000021 8
3
FW-05
600
1435
4
200
167000008
2
W36
FW-05
2
2
BL-19S FR-0
W36
FFL 2.570 SSL 2.500
STAIR WIDTH
162010073
FW-05
3
POOL DURESS ALARM BUTTON AND SPA W36 SHUTDOWN SWITCH
ALIGN
3
REED SWITCH FOR ROLLER SHUTER ELECTRIC STRIKE
10
W36
2. FOR TYPICAL POD (PREFABRICATED BATHROOM) DETAILS REFER TO DRAWINGS AD863500001 SERIES
6. REFLECTED CEILING PLANS TO BE READ IN CONJUNCTION WITH ALL SERVICE DRAWINGS. ALLOW FOR WALL TYPE (REFER TYPICAL WALL DETAILS - ALL CEILING MOUNTED SPRINKLERS, LIGHT FITTINGS, DWG NO.S AD51000001 - AD51000005) ACCESS PANELS & LINEAR GRILLES TO BULKHEADS.
00
T1
1. FOR TYPICAL WALL DETAILS - REFER TO DRAWINGS AD851000001 TO AD51000006.
PERMANENT POWER CONNECTION
W31
GYM
GENERAL NOTES
( REFER TO THE FINISHES & FF&E SCHEDULE FOR DETAILS ) A/C AIR CONDITIONING UNIT (WALL MOUNT) AB ABOVE BENCH AD AUTOMATIC DOOR AT AUTOTAP BB BELOW BENCH BH BULKHEAD BH-I BULKHEAD - WITHIN INTERNAL CEILING ZONE TO SLAB SOFFIT BIR BUILT IN ROBE CT COOK TOP CU CONDENSER UNIT DW DISWASHER DP DOWNPIPE DT DOOR TYPE EF FOR EXHAUST FAN EG EXHAUST GRILLE ES-01 EXPOSED SOFFIT TYPE 1 ES-02 EXPOSED SOFFIT TYPE 2 EF-03 RECESSED SPINKLER EF-04 MECHANICAL EXHAUST FR REFRIGERATOR FS FACADE SOFFIT HZ HYDRAULIC RISER LDY LAUNDRY LG LINEAR BAR GRILLE LT-01 LOBBY LIGHT LT-15 BATHROOM LIGHT LT-16 APARTMENT LIGHT MW MICROWAVE MS MASTER SWITCH OV OVEN PA-01A PAINT TYPE 1A PA-01C PAINT TYPE 1C PA-02A PAINT TYPE 2A PA-02B PAINT TYPE 2B PA-08C PAINT TYPE 8C PB-01 PLASTERBOARD CEILING TYPE 1 1 LAYER 13MM STANDARD PB PB-02 PLASTERBOARD CEILING TYPE 2 2 LAYER 13MM STANDARD PB + 50MM ACOUSTIC INSULATION PB-03 PLASTERBOARD CEILING TYPE 3 2 LAYERS 16MM STANDARD PB + 50MM ACOUSTIC INSULATION PB-04 PLASTERBOARD CEILING TYPE 4 FIRE SEPERATION 120/120/120 PB-05 PLASTERBOARD CEILING TYPE 5 1 LAYER 13MM MOISTURE RESISTANT PB POD POD CEILING BY OTHERS RWO RAIN WATER OUTLET RD ROLLER DOOR RH RANGE HOOD SK-01 SKIRTING TYPE 1 SK-06 SKIRTING TYPE 6 ST STONE THRESHOLD
RM-01 RM-02 TL-01 TL-02 TL-03 TL-04 WS2
RUBBER FLOORING AS SCHEDULED RUBBER FLOORING WITH ACOUSTIC UNDERLAY AS SCHEDULED TILES 300X600 (PORCELAIN) AS SCHEDULED TILES 1200X600 AS SCHEDULED TILES 600X300 AS SCHEDULED TILES GLASS MOSAICS AS SCHEDULED Wall Stiffener 2
NM
NN
NO
NP
SYMBOLS DISTRIBUTION BOARD
3
VESTIBULE
1.0021
FFL 2.570 SSL 2.500
W39
2 861000010
3
1.0022 D001
COMMS
ONT
SINGLE SWITCHED SOCKET OUTLET (GPO)
UAT
1.0022
DOUBLE SWITCHED SOCKET OUTLET (GPO)
FFL 2.570 SSL 2.500
SINGLE LIGHTING SWITCH DOUBLE LIGHTING SWITCH
SC
D
ONE WAY LOCAL DIMMER LIGHTING SWITCH
D622
4
DATA / TELEPHONE OUTLET
4
SC
TELEVISION OUTLET / ANTENNA
W22
5
EXHAUST AIR DUCT
5
Ai
LED RECESSED DOWNLIGHT LED WALL MOUNTED BALCONY LIGHT
LIFT
RECESSED SPRINKLER
L104
5
SP
EXPOSED SPRINKLER
A/C
857500001
AIR CONDITIONER CEILING SPEAKER
W22
SMOKE DETECTOR
LOBBY
1.0020
CONTINUED ON DRAWING No. AD162010070 GLAZING WINDOW WITH BLIND MULLIONS. REFER TO POOL AREA DRAWING 167000012 FOR SET-OUT.
5
NK
TA NL
W41
W41
4
7 861000011
POOL
CEILING TO PREFABRICATED 'POD' TO SEPERATE PACKAGE
1.0070
7
THERMAL INSULATION 50mm THICK KINGSPAN KOOLTHERM K10-F SOFFIT BOARD (R-VALUE = 3.0)
6
W22 FEATURE MIRROR FIXED TO WALL
LIFT
SINGLE LINEAR LIGHTING
L102
DOUBLE LINEAR LIGHTING
7
?
WALL MOUNTED- DOUBLE LINEAR LIGHTING
1.0908- ACCESS03
1.0908- ACCESS02
1.0908- ACCESS01
EMERGENCY DOUBLE LINEAR LIGHTING
5
658 1102
DECORATIVE SCREEN- PERFORATED DOUBLE ALUMINIUM SCREEN ON ALUMINIUM FRAME 161010016
861000010
FFL 2.570 SSL 2.500
1.0011
3
CORNER PROTECTION REFER TO KNAUF PLASTER BOARD SPECIFICATION.
161010017
1.0011 2
R 405
1
W32
W32
161010019
CORRIDOR
4
167000041
FFL 2.570 SSL 2.500
1.0016 D001
161010019
W06 SIM
W06 SIM
5
TR-01 ALUMINIUM REVEAL TO ENTRIES W06 SIM DOOR FINISH TO MATCH PA-08B W06 SIM
BG
900
1.0012 D001
SSL 2.550
291
161010016
161010019
D
D
D615
7
D616
1
10
861000010
167000101
AIRLOCK
P2
CABINETRY DOOR TO FHR CUPBOARD. DOOR FULLY OPENS. SKIRTING CONTINUES AT BASE.
1.0010
FFL 2.570
1.0010 D001
RELOCATED INTERCOM STATION- SUBCONTRACTORS DRAWING TO BE UPDATED MI MATER VIDEO INTERCOM ENTRANCE STATION X2 - ONE AT DDA HEIGHT
Aii MICP
TB PLASTERBOARD LINING FIXED TO FURRING CHANNEL SUBFRAME. PAINTED FINISH.
Ai
SET-OUT TYPE A
Aii
SET-OUT TYPE AII
SC
SET-OUT SWIPE CARD 400
S11
INTERCOM PILLAR (WHEN APPLICABLE). COMPOSITE PANEL BACK AND FRONT. COLOUR TO MATCH GLAZING MULLIONS.
INTERCOM ( IF APPLICABLE) SWIPE CARD
300
5 10
SC
S12
P2
ALLOW FOR 200mm OFFSET TO CENTRELINE OF SWITCH PLATE FROM EDGE OF WALLWHERE APPLICABLE
200
1200
NH PB
NO
FULL HEIGHT FEATURE MIRROR FIXED TO WALL
DOOR FRAME / EDGE OF WALL
10
NN
( REFER TO DWG HEIGHT PRINCIPLE -AD030500001 FOR FURTHER DETAIL)
NJ
861000012
NM
TYPICAL SET-OUT LEGEND
76 0
W32
167000041
TA NL
TR-01 ALUMINIUM REVEAL TO ENTRIES
9
161010021
861000001
161010019
NK
3
8
3
76 0
1
MASTER INTERCOM CONTROL PANEL
DOME CCTV CAMERA
P3 9
INTERCOM STATION
I
CCTV
76 0
SC
ARTWORK LOCATION. SIZE TBC.
SECURITY CONTROL PANEL I
1.0036 D001
FULL HEIGHT FEATURE MIRROR FIXED TO WALL
SSL 2.550
SWIIPE CARD PLATE INTERCOM
FLOOR FINISHES CARPET CP-01/CP-02/CP-03/CP-04
CONCRETE PAVER PV-01
CONCRETE CF-01/CF-02/CF-03/CF-04/CF-05/CF-06/CF-07 STONE ST-01/ST-02/ST-03/ST-04
RUBBER RM-01/RM-02
TILE TL-01/TL-02/TL-03/TL-04/TL-05/TL-06 TIMBER TB-01/TB-02/TB-03
4. FOR FINISHES SCHEDULE AND FF&E FOR APARTMENT GRADE INCLUSIONS AND COLOUR SCHEME SELECTIONS REFER TO SCHEDULE AT-04003 5. PLANS & REFLECTED CEILING PLANS TO BE READ IN CONJUNCTION WITH THE ACOUSTIC SPECIFICATION BY RENZO TONIN ASSOCIATES.
7. REFER TO THE ELECTRICAL ENGINEER'S DOCUMENTATION FOR ALL ELECTRICAL REQUIREMENTS AND HIGH LEVEL ELECTRICAL EQUIPMENT SHOWN ON REFLECTED CEILING PLANS. 8. PROVIDE PAINTED FINGER JOINTED PINE SKIRTING THROUGHOUT (EXCLUDING WET AREAS). 9. SQARE SET TO ALL LIVING, DINING, KITCHEN, BEDROOM AND HALL CEILING PERIMETERS. RONDO P26 STOPPING ANGLE TO ALL INSITU BATHROOMS. 10. ACOUSTIC LAGGING REQUIRED TO ALL HYDRAULIC PIPEWORK IN HYDRAULIC RISERS ADJACENT HABITABLE ROOMS. 11. PROVIDE SUFFICIENT FRAMING WITHIN STUD WALLS FOR ALL FIXTURES, FITTINGS, EQUIPMENT & JOINERY. 12. PROVIDE BOXED STUDS TO ALL DOOR FRAMES & WHERE STUD WALLS STOP WITHOUT RETURN WALLS. PACK ADJACENT STUDS AS NECESSARY TO MAINTAIN PLUMB LININGS. 13. DOOR FRAMES ARE TO BE SETOUT 100MM FROM WALL ON HINGED SIDE OR CENTERED ON THE ROOM OR CORRIDOR UNLESS NOTED OTHERWISE. 14. REFER ARCHITECTURAL DESIGN SPECIFICATION "PARTITIONS AND CEILINGS" - DOCUMENT NO. C5-AS0-2620 15. SERVICE LOCATIONS ARE INDICATIVE AND SUBJECT TO CONFIRMATION BY SERVICES CONTRACTOR 16. WHERE AN ELEMENT HAS BEEN NOTED TO ALIGN WITH ANOTHER ELEMENT BUT DOES NOT DUE TO CONSTRUCTION TOLERANCE, ARCHITECT IS TO BE CONTACTED FOR AN INSTRUCTION. NAMING CONVENTION
LEVEL
SOUNDER
SCP
NOTICE BOARD 1525wX1220h @ 1000 AFFL
861000012
3
3. FOR KITCHEN AND JOINERY DETAILS - REFER TO DRAWINGS AD863000000 SERIES
BUILDING
2 SC
BREAK GLASS FOR DOOR RELEASE
SECURITY DURESS BUTTON
T2 6
KEYPAD
S
1525
4
1.0016
ELECTRIC STRIKE
K
MAIL ROOM 7
REED SWITCH FOR ROLLER SHUTER
EGRESS BUTTON
ST-01
1.0014
SC
INTERCOM PILLAR. COMPOSITE PANEL BACK AND FRONT. COLOUR TO MATCH GLAZING MULLIONS.
W06 SIM
HD
CARD READER
1863
161010017
3
161010016
8
REED SWITCH
1.0065
W32
ST-01
861000001
RS
ES
BIN WASH AREA
W32
RENDERED GRC COLUMN. APPLIED FINISH PA-02A.
SC
8
861000010
W32
Ai
MOTION DETECTOR
RS
Aii
T2
EXIT SIGN WITH ARROW
CEILING SLOT 800 X 250 (MAKE UP AIR)
W32
CORNER PROTECTION REFER TO PLASTER BOARD SPECIFICATION.
FFL 2.570 SSL 2.500
861000012
STONE TILES R
EXIT
W22
LOBBY RESIDENTIAL
300
EXIT SIGN
M.
4
3
EXIT
L101
BUSINESS LOUNGE FFL 2.570
2139
LOBBY RESIDENTIAL
P3
360
615
300 486
300
857500001
975
ELECTRICAL FLOOR BOX AS SCHEDULED
FB-01 TO BE MADE IN SAME SIZE WITH TILE 300 X 300.
8
RECESSED EMERGENCY LUMINAIRE
LIFT
975
5
405
975
PIVOTED ACCESS DOORS IN DECORATIVE SCREEN FOR CLEANING GLASS WALL BEHIND.
EMERGENCY SINGLE LINEAR LIGHTING
W22
1.0908- ACCESS04
2. FOR TYPICAL POD (PREFABRICATED BATHROOM) DETAILS REFER TO DRAWINGS AD863500001 SERIES
6. REFLECTED CEILING PLANS TO BE READ IN CONJUNCTION WITH ALL SERVICE DRAWINGS. ALLOW FOR WALL TYPE (REFER TYPICAL WALL DETAILS - ALL CEILING MOUNTED SPRINKLERS, LIGHT FITTINGS, DWG NO.S AD51000001 - AD51000005) ACCESS PANELS & LINEAR GRILLES TO BULKHEADS.
00
167000103
1. FOR TYPICAL WALL DETAILS - REFER TO DRAWINGS AD851000001 TO AD51000006.
PERMANENT POWER CONNECTION
6
4
6
W41
161010021
TB
167000012
W25
MECHANICAL TUNDISH
L103
1
861000011
LIFT
2000
NJ
CEILING ACCESS PANEL
A
ST-01
5
7
NH PB
P
FFL 2.570 SSL 2.500
GENERAL NOTES
TACTILES TI-01
1 161010021
NP
ABBREVIATIONS
( REFER TO THE FINISHES & FF&E SCHEDULE FOR DETAILS ) A/C AIR CONDITIONING UNIT (WALL MOUNT) AB ABOVE BENCH AD AUTOMATIC DOOR AT AUTOTAP BB BELOW BENCH BH BULKHEAD BH-I BULKHEAD - WITHIN INTERNAL CEILING ZONE TO SLAB SOFFIT BIR BUILT IN ROBE CT COOK TOP CU CONDENSER UNIT DW DISWASHER DP DOWNPIPE DT DOOR TYPE EF FOR EXHAUST FAN EG EXHAUST GRILLE ES-01 EXPOSED SOFFIT TYPE 1 ES-02 EXPOSED SOFFIT TYPE 2 EF-03 RECESSED SPINKLER EF-04 MECHANICAL EXHAUST FR REFRIGERATOR FS FACADE SOFFIT HZ HYDRAULIC RISER LDY LAUNDRY LG LINEAR BAR GRILLE LT-01 LOBBY LIGHT LT-15 BATHROOM LIGHT LT-16 APARTMENT LIGHT MW MICROWAVE MS MASTER SWITCH OV OVEN PA-01A PAINT TYPE 1A PA-01C PAINT TYPE 1C PA-02A PAINT TYPE 2A PA-02B PAINT TYPE 2B PA-08C PAINT TYPE 8C PB-01 PLASTERBOARD CEILING TYPE 1 1 LAYER 13MM STANDARD PB PB-02 PLASTERBOARD CEILING TYPE 2 2 LAYER 13MM STANDARD PB + 50MM ACOUSTIC INSULATION PB-03 PLASTERBOARD CEILING TYPE 3 2 LAYERS 16MM STANDARD PB + 50MM ACOUSTIC INSULATION PB-04 PLASTERBOARD CEILING TYPE 4 FIRE SEPERATION 120/120/120 PB-05 PLASTERBOARD CEILING TYPE 5 1 LAYER 13MM MOISTURE RESISTANT PB POD POD CEILING BY OTHERS RWO RAIN WATER OUTLET RD ROLLER DOOR RH RANGE HOOD SK-01 SKIRTING TYPE 1 SK-06 SKIRTING TYPE 6 ST STONE THRESHOLD
0.0000
APARTMENT / LOBBY
GENERAL NOTES
ABBREVIATIONS
1. FOR TYPICAL WALL DETAILS - REFER TO DWGS AD88100001, 02 & 03.
BH BIR CF-01 COMMS CPT-01 CPT-02 DP DT EG FF-01 FF-02 FF-03 FF-05 LDY LG LIN H P1 P2 PB1
SYMBOLS STEAM MILL LN (FORMERLY DICKSON LN)
SWITCH 1100MM AFFL 200MM FROM WALL EDGE W/M
CUSTOM MADE ACCESS PANEL 450 x250
DGPO
EQ EQ
TYPICAL SETOUT NOTES: 1. 2. 3.
P1
POD SETOUTS OF GPO'S & SWITCHES - REFER TO SHOP DRAWING KITCHEN SETOUTS OF GPO'S - REFER TO JOINERY PACKAGE (AD88300005) FOR ALL TYPICAL SETOUTS - REFER TO TYPICAL APARTMENT HEIGHT PRINCIPLES - (AD88300001)
P
EQ
TUB
EQ 150 MIN.
250 TYP.
DOWN LIGHT
6. REFLECTED CEILING PLANS TO BE READ IN CONJUNCTION WITH ALL SERVICE DRAWINGS. ALLOW FOR ALL CEILING MOUNTED SPRINKLERS, LIGHT FITTINGS, ACCESS PANELS & LINEAR GRILLES TO BULKHEADS.
SPRINKLER (EF-04)
7. REFER TO THE ELECTRICAL ENGINEER'S DOCUMENTATION FOR ALL ELECTRICAL REQUIREMENTS. HIGH LEVEL ELECTRICAL SHOW ON RCP.
SETOUT POINT FOR BALCONY FLOOR FINISH
BED
BED SETOUT LINE
PB2
8. PROVIDE PAINTED FINGER JOINTED PINE SKIRTING THROUGHOUT (EXCL. WET AREAS).
SETOUT FROM REAR TUB CORNER
PB3
9. RONDO P50 SHADOWLINES TO ALL LIVING ROOM & BEDROOM 2700 CEILINGS. RONDO P26 STOPPING ANGLE TO ALL HALLWAY, KITCHEN, INSITU BATHROOM 2400 & 2350 CEILING ZONES
MECHANICAL EXHAUST APPLY TO SUIT LAUNDRY ORIENTATION
TYPICAL SETOUT LEGEND
750
PB2 2400
EQ
GPO
150 150 MIN.
TMV
FFL 11.425
A
5. PLAN & RCP TO BE READ IN CONJUNCTION WITH THE ACOUSTIC SPECIFICATION.
MECH. EXHAUST (DIA 319mm)
LEVEL 02
PB1 2700
4. REFER TO 'SJB INTERIORS' FINISHES SCHEDULE AND FF&E FOR APARTMENT GRADE INCLUSIONS AND COLOUR SCHEME SELECTIONS.
260
BI-FOLD JOINERY DOOR 94MM TOP TRACT
( REFER TO DRAWING DD-1001 FOR FURTHER DETAILS)
PB4 PB5
10. ACOUSTIC LAGGING REQUIRED TO ALL HYDRAULIC PIPEWORK IN HYDRAULIC RISERS ADJACENT HABITABLE ROOMS.
PB6
11. PROVIDE SUFFICIENT FRAMING WITHIN STUD WALLS FOR ALL FIXTURES, FITTINGS, EQUIPMENT & JOINERY.
RWO ST TMV XA-01
12. PROVIDE BOXED STUDS TO ALL DOOR FRAMES & WHERE STUD WALLS STOP WITHOUT RETURN WALLS. PACK ADJACENT STUDS AS NECESSARY TO MAINTAIN PLUMB LININGS. 13. APARTMENT DOOR FRAMES ARE TO BE SETOUT 100MM FROM WALL ON HINGED SIDE OR CENTERED ON THE ROOM OR CORRIDOR UNO.
SINGLE 10A SWITCHED SOCKET OUTLET (GPO) DOUBLE 10A SWITCHED SOCKET OUTLET (GPO) LIGHTING SWITCH
1.C 3000
LIGHTING SWITCHES (4 BUTTON) DATA / TELEPHONE OUTLET
650 BIR
2825 BEDROOM 1
740
1360
0 - 0X
TELEVISION OUTLET / ANTENNA EXHAUST AIR DUCT
90
610 LIN
LED WALL MOUNTED BALCONY LIGHT
1840 POD
98
650
850
5400
DT 100
ST
FF-01 FF-02
H
130
01
06A
800 LDY
LDY
FW
850
BH/LG - 2450
PB2 2400
BULKHEAD 2400
H
BED
250
1350
BEDROOM 1
500
POD PB6 2300
PB4 2700
750
A
BH 565
COMMS /LIN
20
1610
2820 POD
ST
A
BIR
P1
LIGHTING SWITCHES & KILL SWITCH ON LATCH SIDE OF DOOR
565
KITCHEN (1-WALL-1)
2550
600
900
LIVING \ DINING
DT 110
PB1 2700
310 LIN
04
P1
FF-02
05
05
BH OVER
810
LIVING / DINING
1125
BED
FF-01 1250
POD TYPE CM
DT 120
810
06
TMV
JULIETTE BALCONY
3010 BEDROOM 90
155
800 KITCHEN
BIR
14
CPT-01
230
1.09
130
130
1125
5025 LIVING / DINING
5400
2945 - BIR
1500
245
H
BEDROOM 1
1905
H
01
04
4955
1.08
200
1.08 08
3000
1540
H
PB2 2400
EG
810
1.09 810
H
810
340
1250
355
890
PB2 2400
3180 LIVING / DINING
905
2095
1800 3900 KITCHEN
100
1100 LDY
P
650
600
?
105135 240
2
APARTMENTS
RCP - SW1 - STACK O - ST_TYPE 1 - LV 01-04 1 : 50
A
A
P
2280
COMMS PB2 2400 /LIN 675 850 P
KITCHEN
L
FIRE SPRINKLER SPRINKLER HEAD
H
CEILING SPEAKER SMOKE ALARM SMOKE DETECTOR P A
M
CEILING ACCESS PANEL (TYP. 450X450)
N
VIDEO INTERCOM
1.D
1075
1477
Key Plan
LED RECESSED DOWNLIGHT
00
STACK
75 335 RISER 1465
HA YS TR EE T
O P
FCU SENSOR
1.C
4455
SW3
N
FCU CONTROLER
313
900
4955
750
2280
90
1.B
BH/LG - 2450
3180 LIVING / DINING
1.A
1050
4455
1.D
850
1.B
PODIUM
LIGHTING SWITCHES (3 BUTTON)
LEVEL
1.A
SW2
LIGHTING SWITCHES (2 BUTTON)
NAMING CONVENTION
BUILDING
SW1
LDY PB2 2400
H
H
TUMBALONG BOULEVARD
3. REFER TO 'INTERIORS' DOCUMENTATION FOR ALL KITCHENS & JOINERY. DD900 SERIES-KITCHENS & DD1000 SERIES-LINEN / COMMS CUPBOARD / WARDROBES
DISTRIBUTION BOARD / COMMS CUPBOARD TYPE A/B
DARLING DRIVE
2. PODS (PREFABRICATED BATHROOMS) - REFER TO DWG NO.S AD86000010 - AD86000060.
BULKHEAD BUILT IN ROBE CEMENT RENDER (BALCONY SOFFIT) COMMUNICATIONS CUPBOARD CARPET TYPE 1 CARPET TYPE 2 (SKYHOMES) DOWNPIPE DOOR TYPE EXHAUST GRILLE TIMBER FLOOR FLOOR TILE BALCONY FLOOR TILE TERRACE TIMBER FLOOR LAUNDRY LINEAR BAR GRILLE LINEN CUPBOARD HYDRAULIC RISER PELMET TYPE 1 (ANGLE) PELMET TYPE 2 (PB) PLASTERBOARD CEILING TYPE 1 1 LAYER 13MM STANDARD PB PLASTERBOARD CEILING TYPE 2 1 LAYER 13MM STANDARD PB + 75MM ACOUSTIC INSULATION (MR PB WET AREAS) PLASTERBOARD CEILING TYPE 3 2 LAYERS 13MM FIRE RATED PB PLASTERBOARD CEILING TYPE 4 2 LAYERS 13MM STANDARD PB + 75MM ACOUSTIC INSULATION (MR PB WET AREAS) PLASTERBOARD CEILING TYPE 5 2 LAYERS 13MM FIRE-RATED PB + 75MM ACOUSTIC INSULATION (MR PB WET AREAS) CEILING TYPE 6 (PODS) 1 LAYER 13MM USG BOARD & 3MM KERLITE PANEL RAIN WATER OUTLET STONE THRESHOLD THERMOSTATIC METERING VALVE BOX KINGSPAN KOOLTHERM 60MM THICK K10-FM SOFFIT BOARD (R-VALUE = 3.0)
WALL TYPE (REFER TYPICAL WALL DETAILS - DWG NO.S AD88100001 & AD88100002)
APARTMENT TYPE REFERENCE BUILDING IDENTIFIER
1
APARTMENT NO.
1O, 2O, 3O, 4O
BEDROOMS
STUDIO
APARTMENT AREA
42 m²
BALCONY AREA
0 m²
TOTAL APARTMENT AREA
42 m²
GRADE
APARTMENT
GENERAL NOTES
ABBREVIATIONS
1. FOR TYPICAL WALL DETAILS - REFER TO DWGS AD88100001, 02 & 03.
BH BIR CF-01 COMMS CPT-01 CPT-02 DP DT EG FF-01 FF-02 FF-03 FF-05 LDY LG LIN H P1 P2 PB1
SYMBOLS STEAM MILL LN (FORMERLY DICKSON LN)
SWITCH 1100MM AFFL 200MM FROM WALL EDGE
4. REFER TO 'SJB INTERIORS' FINISHES SCHEDULE AND FF&E FOR APARTMENT GRADE INCLUSIONS AND COLOUR SCHEME SELECTIONS. 5. PLAN & RCP TO BE READ IN CONJUNCTION WITH THE ACOUSTIC SPECIFICATION.
260
BI-FOLD JOINERY DOOR 94MM TOP TRACT W/M
DGPO
TYPICAL SETOUT NOTES: 1. 2. 3.
POD SETOUTS OF GPO'S & SWITCHES - REFER TO SHOP DRAWING KITCHEN SETOUTS OF GPO'S - REFER TO JOINERY PACKAGE (AD88300005) FOR ALL TYPICAL SETOUTS - REFER TO TYPICAL APARTMENT HEIGHT PRINCIPLES - (AD88300001)
EQ
GPO
EQ
TUB
EQ 150 MIN.
150 150 MIN.
TMV
MECH. EXHAUST (DIA 319mm)
250 TYP.
DOWN LIGHT
6. REFLECTED CEILING PLANS TO BE READ IN CONJUNCTION WITH ALL SERVICE DRAWINGS. ALLOW FOR ALL CEILING MOUNTED SPRINKLERS, LIGHT FITTINGS, ACCESS PANELS & LINEAR GRILLES TO BULKHEADS.
SPRINKLER (EF-04)
7. REFER TO THE ELECTRICAL ENGINEER'S DOCUMENTATION FOR ALL ELECTRICAL REQUIREMENTS. HIGH LEVEL ELECTRICAL SHOW ON RCP. 8. PROVIDE PAINTED FINGER JOINTED PINE SKIRTING THROUGHOUT (EXCL. WET AREAS).
SETOUT FROM REAR TUB CORNER
SETOUT POINT FOR BALCONY FLOOR FINISH
BED
BED SETOUT LINE
PB3
9. RONDO P50 SHADOWLINES TO ALL LIVING ROOM & BEDROOM 2700 CEILINGS. RONDO P26 STOPPING ANGLE TO ALL HALLWAY, KITCHEN, INSITU BATHROOM 2400 & 2350 CEILING ZONES
MECHANICAL EXHAUST APPLY TO SUIT LAUNDRY ORIENTATION
TYPICAL SETOUT LEGEND
PB2
( REFER TO DRAWING DD-1001 FOR FURTHER DETAILS)
PB4 PB5
10. ACOUSTIC LAGGING REQUIRED TO ALL HYDRAULIC PIPEWORK IN HYDRAULIC RISERS ADJACENT HABITABLE ROOMS.
PB6
11. PROVIDE SUFFICIENT FRAMING WITHIN STUD WALLS FOR ALL FIXTURES, FITTINGS, EQUIPMENT & JOINERY.
RWO ST TMV XA-01
12. PROVIDE BOXED STUDS TO ALL DOOR FRAMES & WHERE STUD WALLS STOP WITHOUT RETURN WALLS. PACK ADJACENT STUDS AS NECESSARY TO MAINTAIN PLUMB LININGS. 13. APARTMENT DOOR FRAMES ARE TO BE SETOUT 100MM FROM WALL ON HINGED SIDE OR CENTERED ON THE ROOM OR CORRIDOR UNO.
SINGLE 10A SWITCHED SOCKET OUTLET (GPO) DOUBLE 10A SWITCHED SOCKET OUTLET (GPO) LIGHTING SWITCH
6875 4400 LIVING / DINING 1205
90
1650
245
1250
90
2165 BIR
3290 BULKHEAD
6
H 08
SIM 09
DP
RWO
BL-14S FR -
09
H
2.F
630
150
06100123
02
09
P
GS-02
A
EQ BH/LG - 4050
FF-03
LIVING / DINING PB2 2700
120
P1
CF-01A 2780
COMMS 02 /LIN
H 03
01
H
APARTMENTS
2.G
810 RISER 810 LDY / LIN
90
1215 1865
1862 1650
90
1925 BIR 3345 BEDROOM 1
245
900 EQ
BH/LG - 2400
PB5 2390
785
PB1 2250
H
850
BEDROOM 1 H
PB1 2700
350 386 EQ
500 PB2 2400
P A
1840 - POD
1250 ENTRY
BIR
09
02
LDY
EG
PB2 2400
POD
BH
06
05
H
PB2 2400
EQ
1635
BIR
850 1500 EQ
19
ST
LIGHTING SWITCHES & KILL SWITCH ON LATCH SIDE OF DOOR
650
975
CPT-01
FF-02
EQ
ENTRY
EQ
DT 100
BEDROOM 1
05
PB2 2400
A
POD TYPE CM
A
90 LIN
1100
90
05
BEDROOM 1
FF-02
20 3000
LDY
ENTRY
A
EQ
2735
DT 110
TMV FW
P
BH OVER
120
06A
200 250
575
250 200 3020
ST
H
2820 - POD
06
23
CORR.
975 430
RISER LDY
1140
ENTRY
07
1125
05
06
04
90
BIR
DT 105
1100
PB2 2400
EQ
OF
16
BED
3740
04
FF-01
2.G
EQ
04 04
1200
KITCHEN 8150
EQ 90
8150
EQ
1140
EQ
FF-01
1140
EQ
BH
300 300
FF-01
BALCONY
LIVING \ DINING
BH OVER
LIVING / DINING
4080
OF
KITCHEN (3-WALL-2)
1250
EQ
1270 OPENING
6875
2.04
900
800
575
2.03
EQ
800 KITCHEN
1250
2.02
2.04
270
1100
2.F
2.03
900
2.02
P2
STACK
PODIUM
LIGHTING SWITCHES (3 BUTTON) LIGHTING SWITCHES (4 BUTTON)
SW3
N
DATA / TELEPHONE OUTLET
HA YS TR EE T
TELEVISION OUTLET / ANTENNA EXHAUST AIR DUCT
Key Plan
LED RECESSED DOWNLIGHT LED WALL MOUNTED BALCONY LIGHT
S
FIRE SPRINKLER
R
SPRINKLER HEAD CEILING SPEAKER
Q C
SMOKE ALARM SMOKE DETECTOR P A
H
P D
CEILING ACCESS PANEL (TYP. 450X450)
O
VIDEO INTERCOM FCU CONTROLER
LEVEL 0 - 0X
SW2
LIGHTING SWITCHES (2 BUTTON)
NAMING CONVENTION
BUILDING
SW1
TUMBALONG BOULEVARD
3. REFER TO 'INTERIORS' DOCUMENTATION FOR ALL KITCHENS & JOINERY. DD900 SERIES-KITCHENS & DD1000 SERIES-LINEN / COMMS CUPBOARD / WARDROBES
DISTRIBUTION BOARD / COMMS CUPBOARD TYPE A/B
DARLING DRIVE
2. PODS (PREFABRICATED BATHROOMS) - REFER TO DWG NO.S AD86000010 - AD86000060.
BULKHEAD BUILT IN ROBE CEMENT RENDER (BALCONY SOFFIT) COMMUNICATIONS CUPBOARD CARPET TYPE 1 CARPET TYPE 2 (SKYHOMES) DOWNPIPE DOOR TYPE EXHAUST GRILLE TIMBER FLOOR FLOOR TILE BALCONY FLOOR TILE TERRACE TIMBER FLOOR LAUNDRY LINEAR BAR GRILLE LINEN CUPBOARD HYDRAULIC RISER PELMET TYPE 1 (ANGLE) PELMET TYPE 2 (PB) PLASTERBOARD CEILING TYPE 1 1 LAYER 13MM STANDARD PB PLASTERBOARD CEILING TYPE 2 1 LAYER 13MM STANDARD PB + 75MM ACOUSTIC INSULATION (MR PB WET AREAS) PLASTERBOARD CEILING TYPE 3 2 LAYERS 13MM FIRE RATED PB PLASTERBOARD CEILING TYPE 4 2 LAYERS 13MM STANDARD PB + 75MM ACOUSTIC INSULATION (MR PB WET AREAS) PLASTERBOARD CEILING TYPE 5 2 LAYERS 13MM FIRE-RATED PB + 75MM ACOUSTIC INSULATION (MR PB WET AREAS) CEILING TYPE 6 (PODS) 1 LAYER 13MM USG BOARD & 3MM KERLITE PANEL RAIN WATER OUTLET STONE THRESHOLD THERMOSTATIC METERING VALVE BOX KINGSPAN KOOLTHERM 60MM THICK K10-FM SOFFIT BOARD (R-VALUE = 3.0)
00
APARTMENT TYPE REFERENCE
FCU SENSOR
BUILDING IDENTIFIER
3
WALL TYPE (REFER TYPICAL WALL DETAILS - DWG NO.S AD88100001 & AD88100002)
APARTMENT NO.
1S, 2S, 3S, 4S
BEDROOMS
1
APARTMENT AREA
48 m²
BALCONY AREA
8 m²
TOTAL APARTMENT AREA
56 m²
GRADE
APARTMENT
SW1
SW2
TUMBALONG BOULEVARD
DARLING DRIVE
STEAM MILL LN (FORMERLY DICKSON LN)
SW3
N
HA YS TR EE T
Key Plan FACADE LEGEND NOTES
1. REFER TO THE SCHEDULE OF EXTERNAL FINISHES FOR CODE DESCRIPTIONS 2. REFER TO SECTION "J " SUMMARY & ASSUMPTIONS DATED 4 JUNE 2014 FOR FACADE INSULATION REQUIREMENTS 3. TO BE READ IN CONJUCTION WITH AS00001130 FACADE SPECIFICATION (ARUP) ACOUSTIC SPECIFICATION (RTA) REFLECTIVITY STUDY (ARUP) WIND TUNNEL TEST REPORT (CPP) FACADE CODES
AL-01, 02, . . AW-01, 02 . . BL-01, 02 . . BR-01, 02 . . CD-01, 02 . . CF-01, 02 . . CR-01 GS-01, 02 02 PC-01 RS-01 GL-01, 02 PA- 80 TB-01,02
ALUMINIUM LOUVRE TYPE 01, 02, . . AWNING TYPE 01, 02 . . BALUSTRADE TYPE 01, 02 . . BRICKWORK TYPE 01, 02 . . CLADDING TYPE 01, 02 . . CONCRETE FINISH TYPE 01, 02 . . CEMENT RENDER TYPE 01 GLAZED SCREEN TYPE 01, PRECAST PANEL TYPE 01 ROLLER SHUTTER TYPE 01 GLAZED TYPE 01, 02 POWDER COASTED FINISH TIMBER CLADDING FINISH
ABBREVIATIONS
DP EG FFL FW OF PB RWO SSL S/S
REFER DWG
2
2
06004012
06004010
3.D 11
01 / 06100130
5425
12
3.A
9260
3740
3.B
7400
3.C
3550
1
4
06004130
06004130
3.D
3.E
7000
2
2
3
06004131
06004231
06004231
3.F
7000
3550
3.G
3.H
7400
3740
1
3.I
06004230
AWNING
/ 06100131
CF-01
CF-01
CR-01 CD-07
CARPARK ENTRY
CARPARK EXIT
CF-01
CR-01
PA-80
GL-15
GL-15
GL-10
GL-10
CD-07
CD-07
CD-07
RS-01
SHOPFRONT AND AWNINGS
CR-01
CR-01
CR-01
LEVEL 01 FFL 8.325
GL-15
GL-15
GL-15
AWNING REFER DWG
01 / 06100130
CR-01
TB-01 RS-01
AL-04
AL-04
4725
AWNING REFER DWG 1
CD-08
CD-08
CD-08
BR-03
GROUND FLOOR DARLING DRIVE FFL 3.600 GROUND FLOOR FFL 3.250 FFL 2.735
DOWNPIPE EXHAUST GRILLE FINISHED FLOOR LEVEL FLOOR WASTE OVERFLOW PLASTERBOARD RAIN WATER OUTLET STRUCTURAL SLAB LEVEL STAINLESS STEEL
SW1
SW2 PODIUM
TUMBALONG BOULEVARD
DARLING DRIVE
STEAM MILL LN (FORMERLY DICKSON LN)
SW3
N
HA YS TR EE T
Key Plan FACADE LEGEND NOTES
1. REFER TO THE SCHEDULE OF EXTERNAL FINISHES FOR CODE DESCRIPTIONS 2. REFER TO SECTION "J " SUMMARY & ASSUMPTIONS DATED 4 JUNE 2014 FOR FACADE INSULATION REQUIREMENTS 3. TO BE READ IN CONJUCTION WITH AS00001130 FACADE SPECIFICATION (ARUP) ACOUSTIC SPECIFICATION (RTA) REFLECTIVITY STUDY (ARUP) WIND TUNNEL TEST REPORT (CPP) FACADE CODES
AL-01, 02, . . AW-01, 02 . . BL-01, 02 . . BR-01, 02 . . CD-01, 02 . . CF-01, 02 . . CR-01 GS-01, 02 02 PC-01 RS-01 GL-01, 02 PA- 80 TB-01,02
ALUMINIUM LOUVRE TYPE 01, 02, . . AWNING TYPE 01, 02 . . BALUSTRADE TYPE 01, 02 . . BRICKWORK TYPE 01, 02 . . CLADDING TYPE 01, 02 . . CONCRETE FINISH TYPE 01, 02 . . CEMENT RENDER TYPE 01 GLAZED SCREEN TYPE 01, PRECAST PANEL TYPE 01 ROLLER SHUTTER TYPE 01 GLAZED TYPE 01, 02 POWDER COASTED FINISH TIMBER CLADDING FINISH
ABBREVIATIONS
DP EG FFL FW OF PB RWO SSL S/S
1.01
1.02
1.03
7285
2 06004030
1.04
6900
1.05
6850
1
2
06004031
06004031
6890
4 06004020
1.06 5965
1.07 3445
1.08 2550
1.09 5400
EG
EG
5410
EG
1
1
3
2
3
06004020
06004012
03500120
06004011
06004010
EG AL-06 0115
1.10
AL-06 0116
EG
EG
AL-06 0117
LEVEL 01 FFL 8.325 AL-04 CR-01 REFER DWG N.
01 / 06100130
GL-15
AL-04
AL-04
GL-15
CD-06
GL-15
CD-06
GL-15 CR-01
CD-06
TB-02 CR-01
CR-01
TB-01
TB-01
AL-04
AL-04
CR-01
GL-10 GL-15
GL-15
GL-15
GL-10
GL-10
GL-10 GL-15
GL-15
CD-06
CR-01 CR-01
TB-01
DARLING DRIVE FFL 3.250
CD-06
SHOPFRONT AND AWNINGS
DOWNPIPE EXHAUST GRILLE FINISHED FLOOR LEVEL FLOOR WASTE OVERFLOW PLASTERBOARD RAIN WATER OUTLET STRUCTURAL SLAB LEVEL STAINLESS STEEL
SW1
SW2 PODIUM
TUMBALONG BOULEVARD
DARLING DRIVE
STEAM MILL LN (FORMERLY DICKSON LN)
SW3
N
HA YS TR EE T
Key Plan FACADE LEGEND NOTES
1. REFER TO THE SCHEDULE OF EXTERNAL FINISHES FOR CODE DESCRIPTIONS 2. REFER TO SECTION "J " SUMMARY & ASSUMPTIONS DATED 4 JUNE 2014 FOR FACADE INSULATION REQUIREMENTS 3. TO BE READ IN CONJUCTION WITH AS00001130 FACADE SPECIFICATION (ARUP) ACOUSTIC SPECIFICATION (RTA) REFLECTIVITY STUDY (ARUP) WIND TUNNEL TEST REPORT (CPP) FACADE CODES
AL-01, 02, . . AW-01, 02 . . BL-01, 02 . . BR-01, 02 . . CD-01, 02 . . CF-01, 02 . . CR-01 GS-01, 02 02 PC-01 RS-01 GL-01, 02 PA- 80 TB-01,02
ALUMINIUM LOUVRE TYPE 01, 02, . . AWNING TYPE 01, 02 . . BALUSTRADE TYPE 01, 02 . . BRICKWORK TYPE 01, 02 . . CLADDING TYPE 01, 02 . . CONCRETE FINISH TYPE 01, 02 . . CEMENT RENDER TYPE 01 GLAZED SCREEN TYPE 01, PRECAST PANEL TYPE 01 ROLLER SHUTTER TYPE 01 GLAZED TYPE 01, 02 POWDER COASTED FINISH TIMBER CLADDING FINISH
ABBREVIATIONS
DP EG FFL FW OF PB RWO SSL S/S
M
L
K
8500
8500
J 4345
1
2
1
2
06004222
06004082
06004081
06004070
I 4355
H
G
8500
3 06004060
8500
1.F 2235
1.E 5655
1.D
1.C
4845
4955
1.B 3000
1.A 4455
3
3
2
1
06004050
06004040
06004210
06004030
LEVEL 02
LEVEL 02
FFL 11.425
FFL 11.425
AL-03
3100
SW2 LEVEL 02 FFL 9.900 AW-13
AW-13 CF-01 AL-04
AL-04
AL-04
AL-04
AL-04
FFL 6.750
BL-04
GROUND FLOOR FFL 3.600
COLOR -TBC
CR-01 CR-01
CR-01
SHOPFRONT AND AWNINGS
GL-15
CD-07
D 04
CD-07
D 03
GL-15
CD-07
GL-15
GL-10
GL-15
GL-10
GL-10
GL-15
GL-15 GL-10
REFER DWG N.
GL-15 CD-06
CD-06 GL-15
01 / 06100130
4725
AL-04
SW2 LEVEL 01
DOWNPIPE EXHAUST GRILLE FINISHED FLOOR LEVEL FLOOR WASTE OVERFLOW PLASTERBOARD RAIN WATER OUTLET STRUCTURAL SLAB LEVEL STAINLESS STEEL
SW1
SW2 PODIUM
TUMBALONG BOULEVARD
DARLING DRIVE
STEAM MILL LN (FORMERLY DICKSON LN)
SW3
N
HA YS TR EE T
Key Plan FACADE LEGEND NOTES
1. REFER TO THE SCHEDULE OF EXTERNAL FINISHES FOR CODE DESCRIPTIONS 2. REFER TO SECTION "J " SUMMARY & ASSUMPTIONS DATED 4 JUNE 2014 FOR FACADE INSULATION REQUIREMENTS 3. TO BE READ IN CONJUCTION WITH AS00001130 FACADE SPECIFICATION (ARUP) ACOUSTIC SPECIFICATION (RTA) REFLECTIVITY STUDY (ARUP) WIND TUNNEL TEST REPORT (CPP) FACADE CODES
AL-01, 02, . . AW-01, 02 . . BL-01, 02 . . BR-01, 02 . . CD-01, 02 . . CF-01, 02 . . CR-01 GS-01, 02 02 PC-01 RS-01 GL-01, 02 PA- 80 TB-01,02
ALUMINIUM LOUVRE TYPE 01, 02, . . AWNING TYPE 01, 02 . . BALUSTRADE TYPE 01, 02 . . BRICKWORK TYPE 01, 02 . . CLADDING TYPE 01, 02 . . CONCRETE FINISH TYPE 01, 02 . . CEMENT RENDER TYPE 01 GLAZED SCREEN TYPE 01, PRECAST PANEL TYPE 01 ROLLER SHUTTER TYPE 01 GLAZED TYPE 01, 02 POWDER COASTED FINISH TIMBER CLADDING FINISH
ABBREVIATIONS
2.M
2.L
2.K
2.J
2.I
2.H
2.G
DP EG FFL FW OF PB RWO SSL S/S
2.F
1
3
2
1
1
3
4
4
06004231
06004120
06004121
06004121
06004240
06004120
06004111
06004101
2 06004100
2450
LEVEL 01 FFL 8.325
GL-15
GL-08 GL-15
GL-15
GL-15
GL-15 GL-10
GROUND FLOOR
GL-15
CD-07
GL-15
GL-15
GL-15
D 16
FFL 3.600
CD-06
GL-10
GL-15
GL-10
GL-15
GL-10
GL-15 CD-06
GL-15
GL-15
GL-15
D 13
GL-15
D 12
D 15
BR-03
GROUND FLOOR
3150
2.F
6850
2.E 2
4
06004100
06004101
7550
4000
2.D 2 06004100
6500
7150
2.C
2.B
1
1
5
4
1
06004091
06004091
06004220
06004225
06004312
06004082 06100136
11700
FFL 2.735
8150
2.A 1
2
4170
6050
06004080
9900
7400
LEVEL 02 FFL 11.425 SW2 LEVEL 02 FFL 9.900
FFL 8.325
AL-04
AL-04
GL-15
GL-15
AW-10
GL-15
AW-10 GL-08
AW-13
AL-04
AW-13 COLOR -TBC
GL-15
SW2 LEVEL 01
AW-05 SJ
SJ
GL-15
CR-01
GL-15
GL-15
AW-13
1650
LEVEL 01
FFL 6.750
GL-15
GL-15
FFL 3.600
D 12
GL-15
GL-15
GL-15
GL-10 D 11
GL-15
CR-01
CR-01
GL-15
GL-15 SJ
300
GROUND FLOOR
GL-10 GL-15
CR-01
GL-15
GL-15 SJ
GL-10 D ?
GL-15
BL-04
BL-04
BL-04
2785
GL-10
GROUND FLOOR FFL 3.600
GROUND FLOOR FFL 2.735
SHOPFRONTS AND AWNINGS
DOWNPIPE EXHAUST GRILLE FINISHED FLOOR LEVEL FLOOR WASTE OVERFLOW PLASTERBOARD RAIN WATER OUTLET STRUCTURAL SLAB LEVEL STAINLESS STEEL
13mm THICK FLUSH SET PLASTERBOARD FIXED TO 64mm STEEL STUD FRAME
STEEL STUD WALL FRAMING WITH PLASTERBOARD LINING & THERMAL INSULATION - REFER TO 1:50 APARTMENT LAYOUT PLANS FOR WALL TYPES
PAINTED FINGER JOINTED PINE SKIRTING AND FLOOR FINISH AS SCHEDULED
150
185
PAINTED FINGER JOINTED PINE SKIRTING AND FLOOR FINISH AS SCHEDULED
SW3 HA YS TR EE T
Key Plan 20
FFL. SSL.
20
FFL. SSL.
PODIUM
N
35
FALL (1:80)
185
FALL (1:80)
SW2
BACKING ROD & SEALANT
35 20
20
35
WEEP HOLES AS SPECIFIED
SW1
TUMBALONG BOULEVARD
FLASHING
DARLING DRIVE
STEAM MILL LN (FORMERLY DICKSON LN)
FACADE LEGEND
PC-01
200
450 PODIUM GRID
200
450 PODIUM GRID
NOTES
FACADE CODES
PC-01
PRECAST CONCRETE EDGE BEAM TO STRUCTURAL ENGINEER'S DETAILS PAINT FINISH
PRECAST CONCRETE EDGE BEAM TO STRUCTURAL ENGINEER'S DETAILS PAINT FINISH
INSITU CONCRETE SLAB TO STRUCTURAL ENGINEER'S DETAIL
180
20
DRIP GROOVE
100
DRIP GROOVE
COMPRESSIBLE FILLER WITH ADHESIVE SURFACE FOR CONCRETE CREEP AND THERMAL MOVEMENT
100
CL 2700
BR-01 OR BR-02 GLAZED BRICK AS SPECIFIED
SUSPENDED SET PLASTERBOARD CEILING WITH RONDO P50 SHADOW LINE TO PERIMETER
PLASTERBOARD CEILING - REFER RCPS
EXTENT OF VERTICAL JOINT CAULKING PRIOR TO FORM WORK AND SLAB POURS. COMPLETE REMAINING JONT PRIOR TO INSTALLATION OF INTERNAL LINING
BLIND BY OTHERS
01
DP EG FFL FW OF PB RWO SSL S/S
SIM
01
POWDERCOATED ALUMINIUM DOUBLE HUNG WINDOWS ( CLEAR GLASS ) REFER WINDOW SUB-CONTARCTOR DETAILS
06100108
305
65
BEYOND - 220mm THICK LOADBEARING PRECAST WALL. REFER TO STRUCTURAL ENGINEER'S FOR DETAILS
5
FINGER JOINTED TIMBER PINE TRIM
13
220mm THICK LOADBEARING PRECAST WALL. REFER TO STRUCTURAL ENGINEER'S FOR DETAILS
BR-01
OR
13mm THICK FLUSH SET PLASTERBOARD FIXED TO 64mm STEEL STUD FRAME TO BACK OF GLAZING FRAME; TO MATCH HEIGHT OF WINDOW SUB-CONTRACTORS TRANSOM
BR-02
GLAZED BRICK AS SPECIFIED STACKED BOND, GROUT, FLUSH POINTING, GLAZED CORNER BRICKS 65X65MM METAL ANGLE FINISH TO MATCH WINDOW FRAME
2700
64
2615
220
2650 TYPICAL FLOOR
55
3100 TYPICAL FLOOR
3100 TYPICAL FLOOR
110
95
COMPRESSIBLE FILLER WITH ADHESIVE SURFACE FOR CONCRETE CREEP AND THERMAL MOVEMENT
OUTSIDE
POWDERCOATED ALUMINIUM FRAMED FIXED WINDOWS ( COLOURBACK GLASS ) REFER WINDOW SUBCONTRACTORS DETAILS
INSIDE
220 - VARIES
1100 - TRANSOM
BRICK TIES AS SPECIFIED BY ENGINEER
INSIDE 1100 - TRANSOM
OUTSIDE
STEEL STUD WALL FRAMING WITH PLASTERBOARD LINING & THERMAL INSULATION - REFER TO 1:50 APARTMENT LAYOUT PLANS FOR WALL TYPES DOWEL TO STRUCTURAL ENGINEER'S DETAIL
FLASHING
WEEP HOLES AS SPECIFIED
PRECAST CONCRETE EDGE BEAM TO STRUCTURAL ENGINEER'S DETAILS PAINT FINISH IN SITU CONCRETE SLAB TO STRUCTURAL ENGINEER'S DETAIL
35
20
FFL. SSL.
200 PRECAST CONCRETE EDGE BEAM TO STRUCTURAL ENGINEER'S DETAILS PAINT FINISH
20
DRIP GROOVE
DRIP GROOVE
100
100 COMPRESSIBLE FILLER WITH ADHESIVE SURFACE FOR CONCRETE CREEP AND THERMAL MOVEMENT
FACADE DETAILS SELECTED GLAZED BRICK WALL
PAINTED FINGER JOINTED PINE SKIRTING AND FLOOR FINISH AS SCHEDULED
PC-01
20
BR-01 OR BR-02
185
185 20 200
PC-01
13
450 PODIUM GRID
185
64
PAINTED FINGER JOINTED PINE SKIRTING AND FLOOR FINISH AS SCHEDULED
FFL. SSL. 450 PODIUM GRID
FALL (1:80)
BACKING ROD & POLYURETHANE REAR AIR SEAL- BONDED TO FLASHING
150
35 20
20 12
BACKING ROD & SEALANT
FALL (1:80)
CL 2700 SUSPENDED SET PLASTERBOARD CEILING WITH RONDO P50 SHADOW LINE TO PERIMETER EXTENT OF VERTICAL JOINT CAULKING PRIOR TO FORM WORK AND SLAB POURS. COMPLETE REMAINING JONT PRIOR TO INSTALLATION OF INTERNAL LINING
CL 2700
AL-01, 02, . . AW-01, 02 . . BL-01, 02 . . BR-01, 02 . . CD-01, 02 . . CF-01, 02 . . CF-01 GS-01, 02 PC-01 P1, P2 . .
ALUMINIUM LOUVRE TYPE 01, 02, . . AWNING TYPE 01, 02 . . BALUSTRADE TYPE 01, 02 . . BRICKWORK TYPE 01, 02 . . CLADDING TYPE 01, 02, . . CONCRETE FINISH TYPE 01, 02 . . CEMENT RENDER TYPE 01 GLAZED SCREEN TYPE 01, 02 PRECAST PANEL TYPE 01 PELMET TYPE 01, 02, . .
ABBREVIATIONS
CL 2700
06100108
305
1. REFER TO THE SPECIFICATIONS SCHEDULE OF EXTERNAL FINISHES - AT00004102 - FOR CODE DESCRIPTIONS
DOWNPIPE EXHAUST GRILLE FINISHED FLOOR LEVEL FLOOR WASTE OVERFLOW PLASTERBOARD RAIN WATER OUTLET STRUCTURAL SLAB LEVEL STAINLESS STEEL
FFL. SSL.
80 60
POWDERCOATED ALUMINIUM FRAMED CASEMENT WINDOWS REFER WINDOW SCHEDULE
COMPOSITE ALUMINIUM CLADDING FIXED TO FURRING CHANNEL & BACKING CLIP ON BLOCKWALL & CONCRETE; PACKING WHERE REQUIRED; TO SUBCONTRACTOR'S DETAIL
ROOF
CL 2700
SSL. ROOF
03
18
OUTLINE OF HOB BEYOND
TOH SSL 29.030
CF-01 OFF-FORM CONCRETE SOFFIT GRIND & PATCH AS REQUIRED SKIM COAT & PAINT
BOTTOM OF OVERFLOW SSL 28.960 SSL 28.880
1:80 FALL
OFF-FORM CONCRETE SOFFIT GRIND & PATCH AS REQUIRED SKIM COAT & PAINT
SIM
250
CF-01
250
6 50
80
CL
41
3100 - TYPICAL FLOOR
260 PANEL
DOUBLE GLAZED - Rw42 ACOUSTIC RATING - REFER WINDOW SCHEDULE REFER ACOUSTIC ENGINEERS
WP MASTIC SEALANT FOLDED EDGE
POWDERCOATED ALUMINIUM FRAMED CASEMENT WINDOWS REFER WINDOW SCHEDULE
2780 TYPICAL FLOOR
41
06100108
10.76 50.00 6.76
OUTSIDE
BALCONY
INSIDE PAINTED PB WINDOW SILL
AL-03
POWDERCOATED ALUMINIUM FRAMED WINDOWS REFER WINDOW SUB-CONTRACTORS DETAILS
BEYOND POWDERCOATED ALUMINIUM BATTENS 50 x 50mm AT 100mm CENTERS (VERTICAL)
510
OUTSIDE
AL-03
8mm THICK TIMBER COMPOSITE PANEL WITH OPEN JOINTS & EXPOSED FIXINGS
530 20 200
R.C. SLAB TO STRUCTURAL ENGINEERS DETAILS CD-02 WATERPROOF SEALANT
TIMBER LOOK COMPOSITE PANEL WITH OPEN JOINTS AND EXPOSED FITTINGS
FLASHING OVER CFC BOARD; STEEL SUPPORT TO STRUCTURAL ENGINEERS DETAILS
100
250
300
240 (BETWEEN GRID 2.B & 2.C)
30 20
160
20 160
COMPOSITE ALUMINIUM CLADDING FIXED TO FURRING CHANNEL & BACKING CLIP ON BLOCKWALL & CONCRETE; PACKING WHERE REQUIRED; TO SUB-CONTRACTOR'S DETAIL
SKIRTING AND FLOOR FINISH AS SCHEDULED
20 50
FFL. SSL.
ALIGN
CD-01
300
485 PANEL
CD-02
30
COLOURBACK / INSULATED SPANDREL REFER WINDOW SCHEDULE
470 PANEL
510
ALIGN
485 PANEL SW2 LEVEL 2 FFL 9.90 SSL.9.70
SKIRTING AND FLOOR FINISH AS SCHEDULED
20
1100 TRANSOM
TIMBER LOOK COMPOSITE PANEL WITH OPEN JOINTS AND EXPOSED FITTINGS 13mm THICK FLUSH SET FIRE RATED PLASTERBOARD FIXED TO 64mm STEEL STUD FRAME ACOUSTIC & THERMAL INSULATION AS SPECIFIED IN ACOUSTIC SPECIFICATION & THERMAL MODELING REPORT
INSIDE
POWDERCOATED ALUMINIUM BATTENS 50mm X 50mm AT 100mm CENTERS (VERTICAL)
CD-02
80
WATERPROOF SEALANT
250
60
80
20 RHS STEEL STUB SUPPORTING STRUCTURE & FIXING TO CONCRETE SLAB TO FACADE ENGINEER'S DETAIL
CL 2700 SHOPFRONT GLAZING UNDER DESIGN REVIEW
SUSPENDED SET PLASTERBOARD CEILING WITH RONDO P26 STOPPING ANGLE TO PERIMETER BLIND BY OTHERS
FACADE DETAILS
POWDERCOATED ALUMINIUM FRAMED CASEMENT WINDOWS REFER WINDOW SCHEDULE
STEEL SUPPORT STRUCTURE AND FIXING TO STRUCTURAL ENGINEERS DETAILS
240 (BETWEEN GRID 2.B & 2.C)
HA YS TR EE T
1. REFER TO THE SPECIFICATIONS SCHEDULE OF EXTERNAL FINISHES - AT00004102 - FOR CODE DESCRIPTIONS
SUSPENDED SET PLASTERBOARD CEILING - REFER RCPS
FACADE CODES
AL-01, 02, . . AW-01, 02 . . BL-01, 02 . . BR-01, 02 . . CD-01, 02 . . CF-01, 02 . . CF-01 GS-01, 02 PC-01 P1, P2 . .
ALUMINIUM LOUVRE TYPE 01, 02, . . AWNING TYPE 01, 02 . . BALUSTRADE TYPE 01, 02 . . BRICKWORK TYPE 01, 02 . . CLADDING TYPE 01, 02, . . CONCRETE FINISH TYPE 01, 02 . . CEMENT RENDER TYPE 01 GLAZED SCREEN TYPE 01, 02 PRECAST PANEL TYPE 01 PELMET TYPE 01, 02, . .
ABBREVIATIONS
80
POWDERCOATED ALUMINIUM FRAMED CASEMENT WINDOWS REFER WINDOW SCHEDULE
450mm x 80mm OVERFLOW PENETRATION IN BLOCKWALL & COMPOSITE CLADDING WITH S.S SLEEVE INSERT; METAL TRIM TO MATCH CD-01 FINISH
120 OVERFLOW
BLIND BY OTHERS
1250 PANEL
OUTSIDE
SUSPENDED SET PLASTERBOARD CEILING WITH RONDO P26 STOPPING ANGLE TO PERIMETER
150 HOB BEYOND
130
SW3
N
NOTES
CL 2700
BLIND BY OTHERS
PODIUM
Key Plan FACADE LEGEND
100
20
EXTENDED GLAZING FRAME TO GLAZING CONTRACTORS DETAIL
80
8mm THICK TIMBER COMPOSITE PANEL WITH OPEN JOINTS & EXPOSED FIXINGS
CD-01
FOLDED EDGE
80
200 100 68
80
20 CD-02
RHS STEEL STUB SUPPORTING STRUCTURE & PACKING WHERE REQUIRED; FIXED TO BLOCKWORK TO FACADE ENGINEER'S DETAIL
1220 BALUSTRADE
240 (BETWEEN GRID 2.B & 2.C)
10
30 20
250
COMPOSITE ALUMINIUM CLADDING / SUPPORT FRAMING TO SUBCONTRACTOR'S DETAIL
COMPOSITE ALUMINIUM CLADDING / SUPPORT FRAMING TO SUBCONTRACTOR'S DETAIL
WP MASTIC SEALANT
SW2
80
35
140mm BLOCKWORK WALL CORE FILLED REINFORCED TO STRUCTURAL ENGINEERS DETAIL WITH WP MEMBRANE; FINISH AS SPECIFIED
120
CD-01
SW1
60
8mm THICK TIMBER COMPOSITE PANEL WITH OPEN JOINTS & EXPOSED FIXINGS
160
200 - TYPICAL
300
160
20
20 50
CD-02
300
120 CD-01
250
SKIRTING AND FLOOR FINISH AS SCHEDULED
ALIGN
FFL. SSL.
30
CONCRETE SLAB TO STRUCTURAL ENGINEER'S DETAIL
20
FALL
TOP OF PARAPET.
SHOPFRONT GLAZING AS SCHEDULED AND SPECIFIED
TUMBALONG BOULEVARD
FOLDED COLORBOND CAPPING TO MATCH WALL FINISH
DARLING DRIVE
STEAM MILL LN (FORMERLY DICKSON LN)
DP EG FFL FW OF PB RWO SSL S/S
DOWNPIPE EXHAUST GRILLE FINISHED FLOOR LEVEL FLOOR WASTE OVERFLOW PLASTERBOARD RAIN WATER OUTLET STRUCTURAL SLAB LEVEL STAINLESS STEEL
2 1.D
06004211
DARLING DRIVE
06004211
SW1 PODIUM
SW3
N AL-04
HA YS TR EE T
CONTINUOUS LOUVRE STRIP ABOVE AWNING
AL-04
SW2
TUMBALONG BOULEVARD
1
1.E
STEAM MILL LN (FORMERLY DICKSON LN)
Key Plan AWNING
SW1
AW-01 SW2 L01
100
100
239
305
SSL 6.730
CD-07
ALPOLIC CLADDING AS PER EFS
GL-10
CD-07
CD-07 GL-15
GL-15
GL-15
DT 04
FACADE LEGEND
CD-07 2725
2525
Retail Tenancy Location Plan
NOTES
1. REFER TO THE SCHEDULE OF EXTERNAL FINISHES FOR CODE DESCRIPTIONS FACADE CODES
AL-01, 02, . . AW-01, 02 . . BL-01, 02 . . BR-01, 02 . . CD-01, 02 . . CF-01, 02 . . CR-01 GS-01, 02 PC-01
100100
CD-07
GROUND FLOOR FFL 3.600
ABBREVIATIONS
DP FFL FW OF PB RWO SSL S/S
1
1.E
1.D
06004211
100
2 06004211
4745
CD-07
GL-15
3155
SW1 LOBBY
1
CD-07
06004301
1
FFL 3.600
CD-07
06004301
CD-07
CD-07
CD-07
150 50
RL 3.600
50
CD-07
300
200 350
200
DT 04
CD-07
50
1050
70 100
1050 50
1000
2005
100 70
2445 220
2005
1100
70 100
1000 220
1000
700 920
220
1214 1214 2834
700
100 7050 920
1208 1001 1001
AWNING OVER
LOBBY
ALUMINIUM LOUVRE TYPE 01, 02, . . AWNING TYPE 01, 02 . . BALUSTRADE TYPE 01, 02 . . BRICKWORK TYPE 01, 02 . . CLADDING TYPE 01, 02 . . CONCRETE FINISH TYPE 01, 02 . . CEMENT RENDER TYPE 01 GLAZED SCREEN TYPE 01, 02 PRECAST PANEL TYPE 01
DOWNPIPE FINISHED FLOOR LEVEL FLOOR WASTE OVERFLOW PLASTERBOARD RAIN WATER OUTLET STRUCTURAL SLAB LEVEL STAINLESS STEEL
870
80
850
100
1240
100
3000
1000
250 400100
3000
1.D
4955 100
1920
800
250
100
1150
115
1535
145
2400
295
3. REFER TO 'INTERIORS' DOCUMENTATION FOR ALL KITCHENS & JOINERY. DD900 SERIES-KITCHENS & DD1000 SERIES-LINEN / COMMS CUPBOARD / WARDROBES
45
1965
BH BIR CF-01 COMMS CPT-01 CPT-02 DP DT EG FF-01 FF-02 FF-03 FF-05 LDY LG LIN H P1 P2 PB1
2. PODS (PREFABRICATED BATHROOMS) - REFER TO DWG NO.S AD86000010 - AD86000060.
90 255
1965
1. FOR TYPICAL WALL DETAILS - REFER TO DWGS AD88100001, 02 & 03.
1455
4. REFER TO 'SJB INTERIORS' FINISHES SCHEDULE AND FF&E FOR APARTMENT GRADE INCLUSIONS AND COLOUR SCHEME SELECTIONS. 5. PLAN & RCP TO BE READ IN CONJUNCTION WITH THE ACOUSTIC SPECIFICATION.
DT 100
6. REFLECTED CEILING PLANS TO BE READ IN CONJUNCTION WITH ALL SERVICE DRAWINGS. ALLOW FOR ALL CEILING MOUNTED SPRINKLERS, LIGHT FITTINGS, ACCESS PANELS & LINEAR GRILLES TO BULKHEADS.
ST
10 10
7. REFER TO THE ELECTRICAL ENGINEER'S DOCUMENTATION FOR ALL ELECTRICAL REQUIREMENTS. HIGH LEVEL ELECTRICAL SHOW ON RCP.
1835 2445
12
9. RONDO P50 SHADOWLINES TO ALL LIVING ROOM & BEDROOM 2700 CEILINGS. RONDO P26 STOPPING ANGLE TO ALL HALLWAY, KITCHEN, INSITU BATHROOM 2400 & 2350 CEILING ZONES
215
90
8. PROVIDE PAINTED FINGER JOINTED PINE SKIRTING THROUGHOUT (EXCL. WET AREAS). 4260
ST
DT 100
10. ACOUSTIC LAGGING REQUIRED TO ALL HYDRAULIC PIPEWORK IN HYDRAULIC RISERS ADJACENT HABITABLE ROOMS. 11. PROVIDE SUFFICIENT FRAMING WITHIN STUD WALLS FOR ALL FIXTURES, FITTINGS, EQUIPMENT & JOINERY.
1840 DOOR
METER
14
1840 DOOR
DT 150
1.03
E.COMMS
DT 151
DT 152
17
DT 153
1433
08
DT 154
FOR CONTINUATION PLEASE REFER TO PLAN - SW1 LOBBY - LEVEL 02 - PART 1 A
METER
6850
6850
5360 3633
CPT-03
3445
840
1.04 1070
DT 160
1220
1050
09
12 3175
14 12
L101
1.07 2845
FFL 11.425
SSL 11.405
ST
2550
11b GC 11
11b 11a
1.08 1840
DT 159
6890
10
FF-02
DT 158
DT 100
6890
MECH G. EXHAUST
GARBAGE RM
08
2550
09
4335
115 1840
SW1 LOBBY SSL 11.405
11a 08
1.06
FFL 11.425
MECH REFRIGERANT
1487
DT 161
11b
L102
1210
DT 156
11
09
0 100 R EA CL
250
FS 102
4550
6500
SSL 11.425
11b
FS 101
250
MECH PLANT ROOM
MECH GREASE EXHAUST
115
250
1040
00 10 AR E CL
78mm SPEED PANEL 17 1 16 2 15 17 3 14 4 13 5 12 6 11 7 10 8 9 9 8 10 7 11 6 12 5 13 4 14 3 15 2 16 1 17
STAIR RELIEF & LOBBY SUPPLY
DT 157
10 08
14 12 1220 5195
12
14
190
10 DT 100
5370
2290
1.05
5400
1485
1485
1485
H
30
BLOCKWORK RETURN FOR FIRE RATING PURPOSES
ST
2895 2220
2100
SIM.
1576
1840 DOOR 2350 METER
12 SIM. 190
190
METER
12 2972
DT ST 100
750
08
A
DT 161
1.09
5965
1850
ST
5965
250
205
1220
DT 100
DT 162
1.06 12
FOR CONTINUATION PLEASE REFER TO PLAN - SW1 LOBBY - LEVEL 02 - PART 2 3000 1530
115 55
250 1400 DOOR
55
100
2400 100 400 50
6370
COMMON LOBBY
1000
295 100
900 DOOR
145
PB5 PB6 RWO ST TMV XA-01
1965
45
1965 CORRIDOOR 1220
45 275 45
105 190
1440
100
1365
100
75
DISTRIBUTION BOARD / COMMS CUPBOARD TYPE SINGLE 10A SWITCHED SOCKET OUTLET (GPO) DOUBLE 10A SWITCHED SOCKET OUTLET (GPO) LIGHTING SWITCH
190
0 - 0X
SW2 PODIUM
LIGHTING SWITCHES (3 BUTTON) LIGHTING SWITCHES (4 BUTTON)
N
DATA / TELEPHONE OUTLET TELEVISION OUTLET / ANTENNA EXHAUST AIR DUCT
Key Plan
LED RECESSED DOWNLIGHT LED WALL MOUNTED BALCONY LIGHT FIRE SPRINKLER SPRINKLER HEAD CEILING SPEAKER SMOKE ALARM SMOKE DETECTOR P A
CEILING ACCESS PANEL (TYP. 450X450) VIDEO INTERCOM FCU CONTROLER FCU SENSOR
STACK
SW1
LIGHTING SWITCHES (2 BUTTON)
NAMING CONVENTION
BUILDING
11a
DT 155
PB4
STEAM MILL LN (FORMERLY DICKSON LN)
A/B
LEVEL
3430
11a
PB3
BULKHEAD BUILT IN ROBE CEMENT RENDER (BALCONY SOFFIT) COMMUNICATIONS CUPBOARD CARPET TYPE 1 CARPET TYPE 2 (SKYHOMES) DOWNPIPE DOOR TYPE EXHAUST GRILLE TIMBER FLOOR FLOOR TILE BALCONY FLOOR TILE TERRACE TIMBER FLOOR LAUNDRY LINEAR BAR GRILLE LINEN CUPBOARD HYDRAULIC RISER PELMET TYPE 1 (ANGLE) PELMET TYPE 2 (PB) PLASTERBOARD CEILING TYPE 1 1 LAYER 13MM STANDARD PB PLASTERBOARD CEILING TYPE 2 1 LAYER 13MM STANDARD PB + 75MM ACOUSTIC INSULATION (MR PB WET AREAS) PLASTERBOARD CEILING TYPE 3 2 LAYERS 13MM FIRE RATED PB PLASTERBOARD CEILING TYPE 4 2 LAYERS 13MM STANDARD PB + 75MM ACOUSTIC INSULATION (MR PB WET AREAS) PLASTERBOARD CEILING TYPE 5 2 LAYERS 13MM FIRE-RATED PB + 75MM ACOUSTIC INSULATION (MR PB WET AREAS) CEILING TYPE 6 (PODS) 1 LAYER 13MM USG BOARD & 3MM KERLITE PANEL RAIN WATER OUTLET STONE THRESHOLD THERMOSTATIC METERING VALVE BOX KINGSPAN KOOLTHERM 60MM THICK K10-FM SOFFIT BOARD (R-VALUE = 3.0)
75 325
11
ELECT
11b
13. APARTMENT DOOR FRAMES ARE TO BE SETOUT 100MM FROM WALL ON HINGED SIDE OR CENTERED ON THE ROOM OR CORRIDOR UNO.
1840 DOOR 2350
11b
1220
1124
FHR & FE
1124
115 600
11b
STAIR PRESS
STAIR PRESS
1125
1850
1535
295
1.D
320
1050
1050
H
2310
12. PROVIDE BOXED STUDS TO ALL DOOR FRAMES & WHERE STUD WALLS STOP WITHOUT RETURN WALLS. PACK ADJACENT STUDS AS NECESSARY TO MAINTAIN PLUMB LININGS.
PB2
SYMBOLS
00
WALL TYPE (REFER TYPICAL WALL DETAILS - DWG NO.S AD88100001 & AD88100002)
SW3 HA YS TR EE T
TUMBALONG BOULEVARD
1.C
3000
ABBREVIATIONS
DARLING DRIVE
1.B
GENERAL NOTES