date: 12.10.2015 COVER SHEET
CS
by: jon jay
arch 6481 fall 2015 professor john mckenna
university of south florida school of architecture and community design
FLOOR PLANS AND PARTI MODE
BUILDING SECTIONS WALL SECTION AND DETAILS
date: 12.10.2015
MASSING MODEL SCHEMATIC DESIGN
A1.0
by: jon jay
arch 6481 fall 2015 professor john mckenna
university of south florida school of architecture and community design
INTERIOR RENDERING 1 INTERIOR RENDERING 2
EXTERIOR RENDERING 1 EXTERIOR RENDERING 2 date: 12.10.2015 SCHEMATIC DESIGN
A1.1
by: jon jay
arch 6481 fall 2015 professor john mckenna
university of south florida school of architecture and community design
NEW ADDITION
CLIMATE
OWNER: HILLSBOROUGH COUNTY REAL ESTATE DEPT, PO BOX 1110 TAMPA, FL 33601-1110
TYPE OF CONSTRUCTION:
CLIMATE TAMPA - FLORIDA:
LOCATION: PORT TAMPA CITY LIBRARY 4902 COMMERCE STREET TAMPA, FL 33616
PROPERTY SIZE: 23,346 SF. BUILDING SIZE: 6,956 GSF. YEAR BUILT: 1926 PROPERTY CLASS: B3 LATITUDE: 27.864 LONGITUDE: -82.528 TAX DISTRICT: TA TAMPA PROPERTY USE: 8600 COUNTY OWNED STORIES: 2.00
FOLIO #:
FINISH FLOOR PLAN:
LEGAL DESCRIPTION: PORT TAMPA CITY MAP LOTS 7 8 9 AND 10 BLOCK 107 AND E 97 FT OF LOTS 11 THRU 14 BLOCK 107 AND PART OF VACATED R/W DESC AS FOLLOWS:BEG AT NE COR BLK 107 89 DEG 45 MIN 36 SEC W 42.66 FT N 36 DEG 18 MIN 03 SEC E 32 FT N 34 DEG 37 MIN 59 SEC E 17.41 FT N 89 DEG 45 MIN 36 SEC E 13.82 FT AND S 00 DEG 00 MIN 00 SEC W 40 FT TO POB
ELEMENT CLASS EXTERIOR WALL ROOF STRUCTURE ROOF COVER INTERIOR WALLS INTERIOR FLOORING INTERIOR FLOORING HEAT/AC PLUMBING
CODE C 9 4 4 3 8 6 2 3
CONSTRUCTION DETAIL MASONRY STONE TRUSS (WOOD/METAL) BLT. UP TAR & GRAVEL PLASTER CARPET TERRAZZO CENTRAL TYPICAL
ELEMENT CLASS EXTERIOR WALL ROOF STRUCTURE ROOF COVER INTERIOR WALLS INTERIOR FLOORING INTERIOR FLOORING HEAT/AC PLUMBING
CONSTRUCTION DETAIL MASONRY STONE TRUSS (WOOD/METAL) EPDM GYPSUM BOARD CONCRETE WOOD CENTRAL TYPICAL
AREA:
1ST FLOOR: 6,364 GROSS SQ. FT. 2ND FLOOR:6,783 GROSS SQ. FT.
TOTAL:
13,147 GROSS SQ. FT.
JAN 70 52 AV. PRECIPITATION IN INCH: 2.24
FEB 73 54 2.8
MAR 76 58 3.03
APR 81 63 2.05
MAY 87 70 AV. PRECIPITATION IN INCH: 2.09
JUN 90 75 6.69
JUL 89 74 6.3
AUG 84 68 2.24
SEP 89 74 AV. PRECIPITATION IN INCH: 6.3
OCT 84 68 2.24
NOV 78 60 1.54
DEC 72 54 2.48
TAMPA WEATHER AVERAGES: ANNUAL HIGH TEMPERATURE: ANNUAL LOW TEMPERATURE: AVERAGE TEMPERATURE: AVERAGE ANNUAL PRECIPITATION - RAINFALL:
by: jon jay
138623-0000
BUSINESS PROTECTED MAX HEIGHT 55' SPR
university of south florida school of architecture and community design
EXISTING LIBRARY
arch 6481 fall 2015 professor john mckenna
PROPERTY NOTES
46.31 INCH
JUN. 21 - SUMMER SOLSTICE
PROJECT SITE
PROJECT SITE
OVERALL SITE MAP
GENERAL SITE MAP
NOT TO SCALE
NOT TO SCALE
DEC. 21 - WINTER SOLSTICE
SOLAR DIAGRAM
WEATHER CHART
date: 12.10.2015 PROJECT ANALYSIS
A2.0
CO
M M
ER
CE
ST RE E
T
BRUSHED CONCRETE SIDEWALKS
by: jon jay
CRUSHED WHITE GRANITE GROUND COVER
university of south florida school of architecture and community design
EXISTING 2-STORY MULTI-FAMILY RESIDENTIAL BUILDING 87'-0"
EXISTING 2-STORY MULTI-FAMILY RESIDENTIAL BUILDING
arch 6481 fall 2015 professor john mckenna
ST. AUGUSTINE GRASS LANDSCAPING
25
50'-0"
7' -4
"
EXISTING 2-STORY MULTI-FAMILY RESIDENTIAL BUILDING
150'-0"
BRICK PAVERS
NEW 2-STORY LIBRARY ADDITION FIRST FLR: 6,364 GSF SECOND FLR: 6,783 GSF TOTAL: 13,147 GSF
EXISTING 2-STORY PORT TAMPA CITY LIBRARY 6,956 GSF 14'-4"
240'-0"
S. MASCOTTE ST.
date: 12.10.2015 OVERALL SITE PLAN
N
OVERALL SITE PLAN NOT TO SCALE
A3.0
university of south florida school of architecture and community design
arch 6481 fall 2015 professor john mckenna
by: jon jay
50'-9" 94'-2"
37'-1"
SITTING / READING AREA
CAFE
ADMINISTRATIVE AREA
CIRCULATION DESK
COMPUTER ROOM WOMEN
MEN LOBBY
70'-3"
CORRIDOR / GALLERY
OFFICE 1
OFFICE 2
STACKS AND STUDY AREA
33'-2"
36'-10"
CORRIDOR / GALLERY
6'-7"
CONFERENCE ROOM 1
30'-4"
37'-4"
30'-1"
99'-4" 197'-2"
N
FIRST FLOOR PLAN NOT TO SCALE
date: 12.10.2015 FIRST FLOOR PLAN
A4.0
university of south florida school of architecture and community design
by: jon jay
arch 6481 fall 2015 professor john mckenna OPEN TO BELOW
PUBLIC COMPUTER / READING AREA
PERIODICAL STACKS
CHILDREN'S LIBRARY
ELEC. / MECH. ROOM
OPEN TO BELOW
STACKS AREA OPEN TO BELOW
OPEN TO BELOW
CONF. ROOM 2
N
CONF. ROOM 3
SECOND FLOOR PLAN NOT TO SCALE
date: 12.10.2015 SECOND FLOOR PLAN
A4.1
university of south florida school of architecture and community design
by: jon jay
arch 6481 fall 2015 professor john mckenna
16'-6"
2ND FLOOR
34'-0"
17'-6"
ROOF
1ST FLOOR
BUILDING SECTION THRU EXISTING BUILDING NOT TO SCALE
16'-6"
2ND FLOOR
34'-0"
17'-6"
ROOF
date: 12.10.2015
1ST FLOOR
BUILDING SECTION THRU NEW ENTRANCE NOT TO SCALE
BUILDING SECTIONS
A5.0
EPDM ROOFING SYSTEM OVER 3" METAL DECK
university of south florida school of architecture and community design
PARAPET FLASHING
ROOF DETAIL NOT TO SCALE 16 GA. CORTEN STL. OVER 2" INSUL. 8" CMU BLOCK, REINF'D VERT. AND HORIZ.
by: jon jay
8" CMU BLOCK, REINF'D VERT. AND HORIZ.
arch 6481 fall 2015 professor john mckenna
16K5 STL. JSTS.
CONC. SLAB OVER 3" METAL DECK
16K5 STL. JSTS.
2ND FLOOR DETAIL NOT TO SCALE 16 GA. CORTEN STL. OVER 2" INSUL. 8" CMU BLOCK, REINF'D VERT. AND HORIZ. 4" CONC. SLAB OVER 4" CRUSHED GRAVEL
date: 12.10.2015
CONT. REINF'D. CONC. WALL FOUNDATION
WALL SECTION
FOUNDATION DETAIL
NOT TO SCALE
NOT TO SCALE
WALL SECTIONS AND DETAILS
A6.0
university of south florida school of architecture and community design
UV FILM PROTECTED FACADE GLASS (INTERIOR LAYER)
UV FILM PROTECTED FACADE GLASS (EXTERIOR LAYER)
SADEV SAFCO CLASSIC
by: jon jay
2" MTL. GRATE
arch 6481 fall 2015 professor john mckenna
TYP. ROOF STRUCTURE
SADEV SAFCO CLASSIC SPIDER FITTINGS MECHANICALLY OPERATED LOUVERS
STL. COL. CRUSHED GRAVEL OVER ISOLATED 4" CONC. SLAB
date: 12.10.2015
SPIDER GLASS SYSTEM SECTION NOT TO SCALE
SPIDER GLASS SYSTEM
A7.0
university of south florida school of architecture and community design
by: jon jay
arch 6481 fall 2015 professor john mckenna
ORANGE INSULATED METAL PANEL AWNING CORTEN STEEL PANELS CAST-IN-PLACE CONCRETE WALL CUSTOM ALUMINUM COLUMNS SPIDER GLASS SYSTEM MATCHING ORANGE ACCENT WALLS CUSTOM BUILT-IN BOOK SHELVES CUSTOM RECEPTION AREA MILLWORK HARDWOOD FLOORING
date: 12.10.2015
SCORED CONC. SIDEWALK
ENTRY SEQUENCE
SCORED CONC. SIDEWALK
A8.0
university of south florida school of architecture and community design
by: jon jay
GENERAL PURPOSE MACHINE ROOM-LESS TRACTION ELEVATOR
arch 6481 fall 2015 professor john mckenna
SCHINDLER 3300 MRL
SECOND FLOOR CIRCULATION NOT TO SCALE
SECTION
PLAN
NOT TO SCALE
NOT TO SCALE
EMERGENCY EGRESS STAIRS ELEVATOR
FIRST FLOOR CIRCULATION NOT TO SCALE
date: 12.10.2015 BUILDING CIRCULATION
A9.0
INSULATED METAL PANELS
CENTRIA METALWRAP SERIES MR-300 SYSTEM
WEATHERING STEEL HAS INCREASED RESISTANCE TO ATMOSPHERIC CORROSION WHEN COMPARED TO OTHER STEELS. COR-TEN RESISTS THE CORROSIVE EFFECTS OF RAIN, SNOW, ICE, FOG, AND OTHER METEOROLOGICAL CONDITIONS BY FORMING A COATING OF DARK BROWN OXIDATION OVER THE METAL
METALWRAP IS AN INSULATED COMPOSITE BACKUP PANEL SYSTEM THAT CONSISTS OF OF TWO STEEL SKINS, PERMANENTLY BONDED TO A POURED-IN-PLACE FOAM INSULATING CORE. THE PANEL PROVIDES THERMAL, AIR, WATER AND VAPOR BARRIERS IN A COMPOSITE ASSEMBLY.
ALTERNATE MATERIAL 16GA. BLACKEND STEEL SHEETS
ALTERNATE MATERIAL NONE
by: jon jay
CORTEN 16GA. CORTEN STEEL SHEETS
university of south florida school of architecture and community design
CAST-IN-PLACE CONCRETE
arch 6481 fall 2015 professor john mckenna
CORTEN STEEL
ALTERNATE MATERIAL COMPOSITE WOOD CLADDING
date: 12.10.2015 EXTERIOR MATERIALS
EAST ELEVATION
WEST ELEVATION
NOT TO SCALE
NOT TO SCALE
A10
EXIST. BUILDING STRUCTURE 12" REINF'D CMU BLOCK W8X12 STL. BEAM
university of south florida school of architecture and community design
12" CIP CONC. WALL
arch 6481 fall 2015 professor john mckenna
16K5 STL. BAR JSTS.
by: jon jay
W8X8 STL. COL. CONT. CONC. WALL FOOTING 8" REINF'D CMU BLOCK 4" REIF'D. CONC. SLAB THICKENED CONC. SLAB EDGE ISOLATED CONC. COL. FOOTING
BUILDING STRUCTURE
* 3" MTL DECK OVER STL. JSTS. NOT SHOWN
NOT TO SCALE
CAST-IN-PLACE CONCRETE
CONCRETE MASONRY UNIT (CMU)
STRUCTURAL COMPONENTS
WIDE FLANGE STEEL BEAMS AND COLUMNS
STEEL BAR JOISTS
METAL DECKING
date: 12.10.2015 STRUCTURAL
S1
university of south florida school of architecture and community design
INDOOR AIR HANDLER UNIT
by: jon jay
SUPPLY DUCTS
arch 6481 fall 2015 professor john mckenna
RETURN DUCTS
MECHANICAL SYSTEM LAYOUT NOT TO SCALE
INDOOR AIR HANDLER UNIT TRAIN SOUND-SENSITIVE SOLUTIONS INCREASE OPERATING EFFICIENCY
date: 12.10.2015 MECHANICAL SYSTEM
M1.0
university of south florida school of architecture and community design
HOT WATER SUPPLY COLD WATER SUPPLY
UNDER SINK GREASE TRAP AT CAFE
by: jon jay
TANKLESS WATER HEATER LOCATED IN 2ND FLOOR MECHANICAL ROOM
arch 6481 fall 2015 professor john mckenna
VENT TO ROOF
UNDERGROUND CONNECTION TO MUNICIPAL WATER SUPPLY BY MAIN ROAD
UNDERGROUND CURB BOX. ACCESS TO WATER METER, SHUT-OFF VALVE, AND BACK-FLOW PREVENTER
MUNICIPAL WATER SUPPLY UNDERGROUND CONNECTION BY MAIN ROAD
PLUMBING SYSTEM LAYOUT NOT TO SCALE
TANKLESS WATER HEATER
GREASE TRAP
RHEEM PRESTIGE SERIES: 95
ZURN RC35LP
DIRECT VENT INDOOR .26 GPM MINIMUM FLOW RATE CONTINUOUS HOT WATER, ENERGY SAVING AND COMPACT
UNDER SINK DESIGN LEAK AND RUST FREE 35 GAL./MIN. FLOW RATE 70LBS. MAX CAPACITY
PVC PIPE DRAIN AND VENT LINES EXTERIOR WATER SUPPLY LINES
COPPER PIPING INTERIOR HOT AND COLD WATER SUPPLY LINES
date: 12.10.2015 PLUMBING SYSTEM
P1.0
CLEANOUT AT END OF DRAIN LINE
FLOOR MOUNTED TOILET UNDERMOUNTED SINK AND FAUCET FLOOR DRAIN HOSE BIB DRAIN CLEANOUT
by: jon jay
VENT STACK
university of south florida school of architecture and community design
VENT STACK TO ROOF
arch 6481 fall 2015 professor john mckenna
VENT STACK TO ROOF
HOT AND COLD WATER SUPPLY
DRAIN
TYP. RESTROOM ISOMETRIC PLUMBING LAYOUT NOT TO SCALE
WALL MOUNTED URINAL
FLOOR MOUNTED WATER CLOSET
UNDERMOUNTED SINK
TOUCHLESS FAUCET
K-13520-CP FLUSHOMETER K-4904-ET-0 URINAL
K- 10956 FLUSHOMETER K-4406-L URINAL
K-2297-G-0 SINK
K-7516-CP FAUCET
0.125 GALLONS PER FLUSH (GPF) 14-INCH EXTENDED RIM ALLOWS FOR ADA INSTALLATION WATER EFFICIENCY POINTS IN
1.28 GPF (4.8 LPF) FLUSHOMETER WATER EFFICIENCY POINTS IN
RECTANGULAR LOW PROFILE GLAZED UNDERSIDE
0.5 GPM AERATOR WATER EFFICIENCY POINTS IN MAINTENANCE-FREE ELECTRONIC FAUCET
date: 12.10.2015 RESTROOM PLUMBING
P2.0
ELECTRICAL DISTRIBUTION PANELS W/ SERVICE DISCONNECT SWITCH
METER BOX
120V ELECTRICAL FOR NEW ADDITION
PAD MOUNTED TRANSFORMER 240V ELECTRICAL FOR ELEVATOR
university of south florida school of architecture and community design
by: jon jay
120V ELECTRICAL FOR EXISTING LIBRARY
arch 6481 fall 2015 professor john mckenna
MUNICIPAL POWER SUPPLY UNDERGROUND CONNECTION BY MAIN ROAD
ELECTRICAL SYSTEM LAYOUT NOT TO SCALE
PAD MOUNTED VFI TRANSFORMER
ELECTRICAL DISTRIBUTION PANELS
COOPER POWER SYSTEMS
SEIMENS POWER DISTRIBUTION
3-PHASE 15K
3-PHASE PANELS
date: 12.10.2015 ELECTRICAL SYSTEM
E1.0