installation instructions Concealed cistern equipped with a water saving Dual flush valve
*
W752K
wall support frame
Parts list 1 13 12 8A & 8B
6 7
5 8A
11 14
Operating plate sold separately for : W752, W7520 & 9752
8B
19 10
15
16
17 18 7A
4 3
9
7B
2
The operating plate can be replaced by a push button (see page 31 & 36)
1
N째
Product code
Description
1 Pin - washer - screw subassembly
OR
Nb of parts
9873603
x4
2 Protective ringed tube, threaded rods 9831268
x2
3
100mm diam. WC connector
0709198
x1
3
110mm diam. WC connector
0709199
x1
4 Threaded rod M12 x 200
9852030
x2
5
Water inlet insulation
9835056
x1
6 Stop cock
0709103
x1
7 Paneling install template
9835062
x1
7A Tiling set
9835063
x1
7B WC connector protection
9835064
x1
8A
Complete white operating plate
0709140
x1
8B
Complete white operating plate
0709176
x1
9 WC connector
0709065
x1
10 Flush pipe connector
0709089
x1
11
Dual flush mechanism 2V01
0702067
x1
12 Silent float valve 1590
0701035
x1
13 Right angle bracket
9873227
x4
14
Needle screw
9852021
x4
15 Spacer
9831269
x4
16 Washer 23x13x2
9852031
x2
17 M12 hex nut
9852032
x2
18
Nut cap
9833306
x2
19
Hexagonal flauge nuts
9852041
x2
2
table of contents DESCRIPTION support frame adjustment installing the support frame Installing the WC connector
1-2 4 5
1
2 Adjusting the frames
3
Fixing the frame & connecting the drain
6
4
Attaching the pan
7
5
Connecting the water inlet
8
6 Fitting the tiling with operating plate
5
or push button
7
Cutting the flush pipe connector
11
8
Cutting the WC connector
12
9
Installing the pan
12
Or
5
9
10A Installing the operating plate
13
10B Installing the push button
14
maintenance operations
15
water level adjustments
16
3
support frame A
adjustment
B The support frames can be installed on any type of hard surfaces
C
1m from finished floor reference mark to respect for a 400mm high pan
A
= 150 - 226 mm
B
= 15 - 70 mm (for operating plate) = 15 - 35 mm (for push button)
C
= 400 mm (recommended when compatible with your pan) or 450mm for disabled people
D
= 1095 - 1330 mm = 1095 - 1230 mm on 9771B version
E
= 290 - 525 mm = 290 - 425 mm on 9771B version
4
D
E
installing 1
the support frame Feet adjustment
installing the
wall support frame
WC connector
>40cm
1
2
<40cm
1
Self supporting / UNIVERSALâ&#x20AC;&#x2C6;SUPPORT frame
Clip the WC connector.
2
adjusting the
Feet & BRAckets
Bracket adjustment
After adjusting to the right height, tighten the needle screws ; assemble and adjust the right hand brackets (for a wall mounted installation). The pan height position will be final.
5
wall support / universal support frame
3
fixing the frame and connecting the drain
Adjust the connector by cutting the straight section, if necessary.
ENGLISH
An adapator pipe sleeve to fit the piping may be necessary (not supplied). wall support frame
Install the frame in its final position to validate the adjustments and mark where the holes are to be drilled. Drill, glue the pipe and permanently fasten the frame.
10 mm diametre drilled holes self supporting / universal SUPPORTâ&#x20AC;&#x2C6;FRAME
wall / universal SUPPORTâ&#x20AC;&#x2C6;FRAME
10 mm diametre drilled holes
8 mm diametre drilled holes
6
4
attaching the pan
Select the distance between the fastening rods. Position the 2 hexagonal flauge nuts according to the width between the threaded rods (180 or 230 mm).
Put the slit end of the rod on the pan side to enable the adjusment with a screwdriver.
Allow the thickness of the tiling and pan and add 20 mm for adjustment of the fastening rod.
7
connecting the water inlet
It is recommended to connect the water inlet directly to the stop cock. If a flexible tube is used (not supplied), the two fittings at both extemities of the flexible tube must be installed inside the cistern for safety in case of a leak.
Insulating foam disc
The water inlet can be installed to the left or to the right of the cistern by breaking the feed holeâ&#x20AC;&#x2122;s protective washer (note : factory mounted for a left side water inlet) Refer to the maintenance operations to see how to change the float valve for a right side water inlet installation. Bleeding the water feeding pipe : Remove the float valve by pulling on the tab and then lifting the float valve and its support.
Bleed to evacuate impurities. Make sure the water inlet is sealed correctly to prevent leaking and reinstall the float valve.
It is recommended to test the complete assembly (with the pan and connectors) to make sure it is leak-proof before installing the tiling (replace the paneling between the frame and the pan by wedges). Carry out a few complete toilet cistern filling and flushing cycles.
8
ENGLISH
5
6
A, Installation with operating plate
fitting the
tiling Install the polystyrene template. Place tiling flush with template. The tiling thickness must NOT exceed 70mm.
A(bis), Installation with push button Cut the plate out to allow access to the cistern from the top and put the polystyrene template to cover the hole during the installation of the tiling.
i
The template can be recut and be used as a cover for after the end of the installation.
Donâ&#x20AC;&#x2122;t forget to plan an access hatch in case of any maintenance operations.
Plan a 40 mm diameter hole to install the push button.
The tiling thickness must NOT exceed 35mm.
9
B, Protection of the rods & pipes
This system offers you a large number of personalized finish choices and the tiling structure can be completed with many solutions : - with square plaster panels, bricks, etc. - with marine fiberboard panels - with two superposed BA13 plates - with 1 waterproof BA18 plate The tiling is installed between step 6 and 7 of the installation guide. Regardless of the type of support you select, you will have to cut into the support (plasterboard, fiberboard, etc.) and the so-called paneling (tiling, wall paper, etc.) to have enough space to install :
* the pan feed tube * the straight connecting sleeve * the expanded polystyrene install template. This template will delimit the
space required to install the operating plate. * a access hatch on the cistern when installing the push button version * a push button
Use the cut template printed on the back of the box to determine the respective locations and the size of the various spaces to be cut in the tiling.
10
ENGLISH
Install the threaded rod protections (protective ringed tubes) and expanded polystyrene plugs.
AFTER TILING To facilitate the operations described in steps 7, 8 and 9, apply some grease to the seals of each fitting or tube.
7
CUTTINGâ&#x20AC;&#x2C6;THE FLUSH
TUBE CONNECTOR
Push the tube fully in.
Draw the mark M1 as indicated.
Push the tube fully into the bowl.
Cut the tube as indicated.
Draw the mark M2 as indicated.
Cut at X + 3 mm from the edge
Measure the dimension Y which will be used for the cutting of the drain sleeve in step 8.
11
8
CUTTING THE WC CONNECTOR SLEEVE Push the sleeve fully into the pan.
Draw the marks M3 and M4 Cut straight as indicated.
9
Bevel the connector and the tube.
INSTALLING THE PAN
Push the tube and sleeve onto the frame through the tiling.
Install the pan on the fastening rods.
12
10A
INSTALLING THE OPERATING PLATE
REMOVING THE TEMPLATE
ENGLISH
Remove the template to install the support frame for the operating plate.
installing the support frame Install the support frame : Remove the screws from the frame, fettle the screw head and the frame. Insert the screws slanted as shown on the drawing. Tighten down to the last threads.
Connecting THE OPERATING PLATE TO THE MECHANISM Clic
Clipping onto the control plate. 6/9 l
3/4,5 l
Lock the clip to the button.
Installing the plate.
13
Removing the plate (if necessary) : Unlock the clip. Unclip the button.
10B
installation of the push button
install the button with the nut
Connection of the push button to the mechanism
Clip onto the push button. Clic
Lock the clip to the button.
14
MAINTENANCE
OPERATIONS
To access to the maintenance operations, youâ&#x20AC;&#x2122;ll need to remove the plate or the hatch above the cistern. Removing the float valve
3
1 Close the water inlet. 2 Loosen the float valve nut.
3 Remove the float valve and its support.
Removing the mechanism
1 Pull on the tab and lift the hatch.
2 Remove the mechanism to replace its seal, if necessary.
3 Reinstall the mechanism and the latch.
Warning : Make sure that the latch is blocked in its grooves immobilizing the mechanism. Do not do this Warning : The mechanismâ&#x20AC;&#x2122;s cable must be opposite to the float valve.
15
water level
adjustments
1
ENGLISH
2
Adjust the water level in the cistern using the float valve screw 1. Adjust the “economical” flush using the mechanism screw 2. Tightening = increases the “volume of small flush” Loosening = decreases the “volume of small flush” The product is delivered adjusted at the factory to 3 liters / 6 liters (respectively small / large volume flushes.)
16
ZA les Prairies - 1 route de la Verpillière 38290 FRONTONAS Tél. : +33 4 74 95 77 77 Fax : +33 4 74 95 77 87 E-mail : sas@aliaxis.com
Sanitaire Accessoire Services - S.A.S S.a.s au capital de 238 034 € - APE : 291 F 301 609 269 RCS Lyon N° d’identification TVA : FR 82 301 609 269 Site Internet : www.sas-france.com