Business Unit
Technology Solar solutions DKSH provides the expertise for renewable energy
Energy Australia
MC3 connectors MC3 connector system 1000V DC, 30A
Female cable coupler Type Part number Conductor size (mm²) Cable OD (mm)
Female panel receptacle PV-KBT3 II 32.0002 2-4
Part number Conductor size (mm²) Cable OD (mm)
Part number Conductor size (mm²)
32.0052
Type
PV-AZB3
Part number
32.0008
2-4
Male panel receptacle PV-KST3 II 32.0003 2-4
Type Part number Conductor size (mm²)
Branch plug PV-ADSP3/GWD 32.0053
Type
PV-AZS3
Part number
32.0009
2-4
4.9 - 7.1
Preassembled leads Our preassembled leads are made with high quality Lapp Olflex Solar XLS cable fitted with male and female Multi-Contact connectors. Custom lengths and variations on plug options can be manufactured upon request. Leads manufactured with Multi-Contact FlexSol XL cable are also available. IP68 junction box cable assembly Two preassembled leads independently inserted through a double cable entry sealing insert and terminated into a Lapp Skintop M20 IP68 cable gland. Provides for a safe and IP68 rated entry to junction and terminal boxes. Terminated with MC3 or MC4 cable couplers on one end, and 6mm cable lugs on the other end, 500mm total length.
Tooling Crimp tool and assembly tool required to assemble MC3 connectors.
Male to female 2.5mm² leads
Male to female 4mm² leads
2 metre
XPMC3SOL2.5/2M
2 metre
XPMC3SOL4/2M
5 metre
XPMC3SOL2.5/5M
5 metre
XPMC3SOL4/5M
8 metre
XPMC3SOL2.5/8M
8 metre
XPMC3SOL4/8M
12 metre
XPMC3SOL2.5/12M
12 metre
XPMC3SOL4/12M
15 metre
XPMC3SOL2.5/15M
15 metre
XPMC3SOL4/15M
MC3 2.5mm² Lapp SDI 4mm² Lapp SDI
MC4 XPMC3S2.5M20/0.5 XPMC3S4M20/0.5
Field assembly tool PV-RWZ3
2
Branch socket PV-ADBP3/GWD
4.9 - 7.1
Male cable coupler Type
Type
2.5mm² Lapp SDI 4mm² Lapp SDI
XPMC4S2.5M20/0.5 XPMC4S4M20/0.5
Crimp tool 32.6050
PV-CZ
32.6008
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
MC4 connectors MC4 connector system 1000V DC, 30A
Female cable coupler Type Part number Conductor size (mm²) Cable OD (mm)
Female panel receptacle PV-KBT4/2.5 I 32.0010P0001 1.5 - 2.5
Part number Conductor size (mm²) Cable OD (mm)
Part number Conductor size (mm²) Cable OD (mm)
32.0016P0001
Part number Conductor size (mm²) Cable OD (mm)
PV-AZB4
Part number
32.0018
1.5 - 2.5
4-6
Type Part number Conductor size (mm²)
PV-ADBP4/6 32.0056P0001 4-6
5.5 - 9
Male panel receptacle PV-KST4/2.5 I 32.0011P0001 1.5 - 2.5
Type Part number Conductor size (mm²)
Branch plug PV-ADSP4/2.5 32.0055P0001
Type
PV-AZS4
Part number
32.0019
1.5 - 2.5
3-6
Male cable coupler Type
Conductor size (mm²)
32.0054P0001
Type
Female panel receptacle PV-KBT4/6 II
Male cable coupler Type
Part number
Branch socket PV-ADBP4/2.5
3-6
Female cable coupler Type
Type
Male panel receptacle PV-KST4/6 II 32.0017P0001 4-6
Type Part number Conductor size (mm²)
PV-ADSP4/6 32.0057P0001 4-6
5.5 - 9
Preassembled leads Our preassembled leads are made with high quality Lapp Olflex Solar XLS cable fitted with male and female Multi-Contact connectors. Custom lengths and variations on plug options can be manufactured upon request. Leads manufactured with Multi-Contact FlexSol XL cable are also available.
Tooling A crimp tool is required for reliable connection, spanners are not essential but they do make the job easier.
Male to female 2.5mm² leads
Male to female 4mm² leads
2 metre
XPMC4SOL2.5/2M
2 metre
XPMC4SOL4/2M
5 metre
XPMC4SOL2.5/5M
5 metre
XPMC4SOL4/5M
8 metre
XPMC4SOL2.5/8M
8 metre
XPMC4SOL4/8M
12 metre
XPMC4SOL2.5/12M
12 metre
XPMC4SOL4/12M
15 metre
XPMC4SOL2.5/15M
15 metre
XPMC4SOL4/15M
MC4 crimp tool PV-CZM19100A
Open end spanner (pair) 32.6020.19100
PV-MS
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
32.6024
3
MC cables and tooling MC3 - MC4 adaptor leads 1000V DC, 19A Adaptor leads manufactured from high quality 4mm² Multi-Contact Flex-SolXL cable fitted with MC3 and MC4 MultiContact connectors. Standard length is 20cm.
MC3 - MC4 adaptor leads PV-A-KBT4/KST3
32.6096
MC3 - MC4 adaptor leads PV-A-KBT3/KST4
32.6097
Additional tooling MC3 and MC4 tools An insert and locator will allow the MC4 crimp tool to also crimp MC3 connectors. Spare tapered spindles are available for the MC3 assy tools. Insert suit PV-CZM19100A for MC3 PV-ES-CZM-16100
Locator suit PV-CZM19100A for MC3 32.6021.16100
PV-LOC-A
32.6039
MC3 spindles to suit Bench tool
13000357
Field assy tool (orange)
32.6032
MC3 crimp tool
Field assy tool (grey)
32.6052
PV-CZM16100A
Stripping pliers 32.6020.16100A
Test plug This test plug is used to control the corret engagement of the contact in the insulation when assembling MC4.
Safety lock clip The pluggable safety lock clip secures the MC4 PV plug connection and can only be unlocked with the tool PV-MS.
Test plug
Safety lock clip
PV-PST
4
32.6028
PV-SSH4
PV-AZM
32.6027
Junction boxes Junction boxes are also available for PV modules in numerous designs.
32.5280
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
EPIC® connectors EPIC® SOLAR cabling system 1000V DC, 30A EPIC® SOLAR is a new connector system optimized to meet the requirements of solar technology. EPIC® SOLAR is available as preassembled, injection moulded cable assemblies and as loose connectors. Designed to be extremely simple to assemble with no parts that can be lost and minimized possibilities for assembly errors. Cable couplers The EPIC® SOLAR connector field mountable is preassembled and consists of only two components - the connector part and the SKINTOP® gland. The contact is crimped and the plastic components are simply screwed together. The cable outlet is suitable for cable diameters from 4.5 mm up to 7.3 mm. • TÜV Rheinland: certified • UL: in preparation Panel mount receptacles Built-in plugs serve for fast, simple connection of cables to devices such as inverters and junction boxes. • TÜV Rheinland: certified • UL: in preparation
Female cable coupler Part number Conductor size (mm²) Cable OD (mm)
44428022 2.5 - 4 4.5 - 7.3
Female panel receptacle Part number Conductor size (mm²)
Y splitters Y-splitters make it possible to parallel connect solar modules. Maximum reliability is achieved by means of injection overmolding of the Y-Splitter with OLFLEX® SOLAR cables. • TÜV Rheinland: certified • UL: in preparation
Male cable coupler Part number Conductor size (mm²) Cable OD (mm)
44428020 2.5 - 4 4.5 - 7.3
Male panel receptacle 44420506 2.5 - 4
Part number Conductor size (mm²)
44420505 2.5 - 4
Female to 2x male - 4mm², 500mm
Male to 2x female - 4mm², 500mm
Part number
Part number
44420506
44420505
Tooling The crimp tool serves for simple and reliable crimping of the EPIC® SOLAR products on site.
Crimp tool Part number
44428001
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
5
Wieland DC solar system DC solar gesis® PST40 DC connection system The gesis® PST 40i1 is based on the need to combine a highly reliable contact system with easy termination technology. The silver-plated machined contacts have been proven in the most demanding applications, such as machine tool construction, crane technology, and ship building; they are also ideally suited for wiring in the field. The contacts carry their rated current throughout the entire temperature range; there is no need to derate according to temperature. The IP 68 protection rating, the robust design, as well as the ability to mate with the Multi-Contact MC4 system guarantees flexibility for any installations. Benefits • Quick assembly • UV resistant • High conductivity • IP 68 • MC4 compatible • 1000V up to 40A
Female cable coupler
Male cable coupler
2.5mm²
99.201.0000.7
2.5mm²
99.206.0000.7
4mm²
99.202.0000.7
4mm²
99.207.0000.7
6mm²
99.203.0000.7
6mm²
99.208.0000.7
10mm²
99.204.0000.7
10mm²
99.209.0000.7
Protective cap for female Part number
Protective cap for male 05.566.6380.0
Part number
05.566.6480.0
Ready for wind Electro-technical solutions for wind energy systems Wieland Electric – competence and expertise in green energy technology Wieland views itself as a reliable partner in the field of electrical installation. A company offering a vast number of components meeting the highest quality standards, including a modular system with a decisively unifying characteristic: that it is pluggable. At the same time, the system is continually growing and improving. Its reliability and flexibility make it a sound choice for virtually any application, including both fixed installations, as well as those requiring future modifications.
6
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Wieland AC solar system AC solar gesis速 RST 25 Amp connectors for connecting inverters With its 3 and 5 pole connector system RST 25i3/i5, Wieland offers the optimal solution for AC connections. Preassembled components and IP68 protection enable a fast and safe installation, even under the most adverse conditions. The RST AC system includes connectors for on-site field wiring and device connectors for inverter housings (leading inverter manufacturers already deliver their product with RST connectors installed). Female cable coupler
Inverters are often installed in groups, with the same distance between them. The resulting cable lengths repeat from system to system. The AC side can now be installed similarly to the traditional DC module to module interconnection method. This concept effectively reduces the logistics and installation times to a minimum. This advantage pays off not only for initial installation, but for any subsequent service or add-on work. For servicing, individual inverters can be disconnected from the mains supply by simply unplugging them. The electrical contacts are touchprotected against accidental contact. A quick installation and return to operation ensures a high yield system.
Male cable coupler
10-14 mm cable OD
96.031.4154.3
10-14 mm cable OD
96.032.4154.3
13-18 mm cable OD
96.031.4554.3
13-18 mm cable OD
96.032.4554.3
Female panel receptacle M25 Part number
Male panel receptacle M25 96.031.4054.3
Part number
10-14 mm cable OD
96.051.4154.3
10-14 mm cable OD
96.052.4154.3
13-18 mm cable OD
96.051.4554.3
13-18 mm cable OD
96.052.4554.3
96.051.5054.3
Part number
Female cable coupler
96.032.5054.3
Male cable coupler
Some leading inverter manufacturers also use a 3 pole, 20 Amp version.
Female panel receptacle M25 Part number
Male panel receptacle M25 96.052.5054.3
Female cable coupler - 20 Amp version
Male panel receptacle M25 - 20 Amp version
10-14 mm cable OD
Part number
96.031.4153.1
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
96.032.5053.1
7
Cable Multi-Contact Flex-Sol XL TUV approved premium solar cable Description: Single-pole, double insulated solar cable with fine-wire copper strand. The robust, flexible and space-saving design of FLEXSOL-XL ensures constant electrical and mechanical properties during the whole life of the PV installation. For the insulation of our FLEX-SOL-XL cables we use a chemically cross-linked compound.
In contrast to radiation cross-linked material this exhibits complete and controlled in-depth cross-linking throughout the thickness of the cable sheath. FLEX-SOL-XL cables are also flame retardant, halogen-free, and have particularly low smoke emission in case of fire.
Features: - Class 5 tinned - UV resistant - Cross linked sheath - Ozone resistant - 1000 VDC - Black, blue, red - Halogen free - High oil resistance - TUV - High abrasion certification resistance
Nominal conductor area mm2
Approx overall Ø mm
Stranding
Colour
62.7426.11021
2.5
5.1
50 x 0.25
BLACK
150
62.7426.11022
2.5
5.1
50 x 0.25
RED
150
62.7426.11023
2.5
5.1
50 x 0.25
BLUE
150
62.7427.11021
4
5.8
56 x 0.30
BLACK
100
62.7427.11022
4
5.8
56 x 0.30
RED
100
62.7427.11023
4
5.8
56 x 0.30
BLUE
100
62.7428.11021
6
7.0
84 x 0.30
BLACK
75
62.7428.11022
6
7.0
84 x 0.30
RED
75
62.7428.11023
6
7.0
84 x 0.30
BLUE
75
Outer sheath
Roll size mtrs
Part number
Roll size mtrs
V90HT twin SDI Economical UV resistant twin cable Description: An economical tinned twin core, double insulated black UV resistant flexible cable with red and blue inner cores for identification of longer runs. Australian standards: AS5033 states that PV cables are to be clearly identified so they cannot be mistaken for power cables. This cable meets that requirement without the need for additional labelling.
Features: - Class 5 tinned - UV resistant - PVC/PVC TWIN - Black outer sheath - 900/1500 V DC - Blue and red inner Cable marking: Caution: DC cable - Do not disconnect under load. CAUTION: DC CABLE – DO NOT DISCONNECT UNDER LOAD LAPP KABEL® TWIN V90H-T CABLE
2x4
0.9/1.5KVDC
Nominal conductor area mm2
Dimensions mm
3803590
2.5
12.2 x 5.1
50 x 0.25
BLACK
100 - 500
3803591
4
13.8 x 5.9
56 x 0.30
BLACK
100 - 500
Part number
Stranding
3803592
6
15.0 x 6.5
84 x 0.30
BLACK
100 - 500
3803593
10
16.7 x 8.3
80 x 0.40
BLACK
100 - 500
Also available in other conductor sizes, minimum order quantities apply
8
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Cable Olflex® Solar XLS Cross-linked industry standard solar cable Description: Constructed using class 5, fine stranded tinned copper conductors, and insulated with cross-linked copolymer compound and protected by an outer sheath of black, UV resistant, halogen-free cross-linked copolymer.
Benefits: • Reduced spreading of fire source and formation of toxic combustion gases in event of fire • Exact quantity control during installation by meter marking on the cable sheath
Nominal conductor area mm2
Approx overall Ø mm
0025805
2.5
5.4
0025806
2.5
5.4
0025810
4
0025811
Features: • Weathering, abrasion, and UV resistant • Good heat pressure resistance • Halogen-free and flame retardant • Resistant against ammonia and biogases, oxalic acid, sodium hydroxide, and other chemical media • 900/1500 V DC
Stranding
Inner sheath
Outer sheath
Roll size mtrs
50 x 0.25
BLACK
BLACK
100 - 500
50 x 0.25
RED
BLACK
100 - 500
6.0
56 x 0.30
BLACK
BLACK
100 - 500
4
6.0
56 x 0.30
RED
BLACK
100 - 500
0025815
6
7.1
84 x 0.30
BLACK
BLACK
100 - 500
0025816
6
7.1
84 x 0.30
RED
BLACK
100 - 500
0025820
10
8.9
80 x 0.40
BLACK
BLACK
100 - 500
0025821
10
8.9
80 x 0.40
RED
BLACK
100 - 500
0025825
16
9.8
128 x 0.40
BLACK
BLACK
100 - 500
0025826
16
9.8
128 x 0.40
RED
BLACK
100 - 500
Part number
Note: Please add “S” to the end of the part number to receive 100 mtr rolls, i.e. 0025810S = 4mm 100mtr roll 2
Olflex® Solar V4A High-grade steel armoured solar cable Description: Constructed using class 5, fine stranded tinned copper conductors and insulated with cross-linked polymer, armoured with high-grade stainless steel wire braiding (V4A).
Benefits: • Stainless high-grade (class V4A) steel wire braiding protects against rodents and termites • High thermal capacity for long lasting operation of the PV system in all seasons
Features: • Excellent UV and weathering resistance • Good resistance against ammonia and biogases • Flame retardant according IEC 60332-1-2 • 900/1500 V DC
Nominal conductor area mm2
Approx overall Ø mm
Stranding
0025960
4
7.0
56 x 0.30
0025961
6
8.0
84 x 0.30
Part number
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
9
Cable TP90 Rubber SDI & Earth Super flexible industrial standard power, welding & Earth cable Black / Orange Construction: Class 6 super fine copper wire, White TPR flame-retardant insulation, flame retardant, ozone, oil & UV resistant, orange or black meter marked TPR sheath. Other colours available on request subject to minimum order quantity and lead time.
Earth Construction: Class 6 super fine copper wire. Green / Yellow flame retardant, ozone, oil & UV resistant, TPR meter marked insulation.
Nominal Voltage: 600/1000V Temperature Range: -30oC to +90oC
Minimum Bending Radius: Fixed: 5 x cable diameter Flexing: 15 x cable diameter
Stranding
Approx overall Ø mm Black/orange
Approx overall Ø mm Earth
190 x 0.2
7.8
5.1
318 x 0.2
8.8
6.6
1 x 16
513 x 0.2
10.2
8.2
3801523
1 x 25
783 x 0.2
11.5
10.0
3801785
3801524
1 x 35
1107 x 0.2
12.9
11.4
3801786
3801525
1 x 50
1566 x 0.2
14.8
12.5
3801457
3801787
3801526
1 x 70
2214 x 0.2
17.4
15.2
3801458
3801788
3801527
1 x 95
2997 x 0.2
19.7
17.0
3801459
3801789
3801528
1 x 120
950 x 0.4
21.8
18.2
3801460
3801790
-
1 x 150
1184 x 0.4
24.1
-
3801461
3801791
-
1 x 185
1445 x 0.4
26.6
-
3801462
3801792
-
1 x 240
1908 x 0.4
29.8
-
3801463
3801793
-
1 x 300
2383 x 0.4
33.9
-
Nominal conductor area mm2
3801520
1x6
3801782
3801521
1 x 10
3801453
3801783
3801522
3801454
3801784
3801455 3801456
Orange sheath
Black sheath
Earth
3801451
3801781
3801452
Wind power Lapp cable, connectors and accessories for wind energy Wind energy plays an important role in the Lapp Group. To reflect the importance of this industry, the SBU Wind (Strategic Business Unit Wind) has been set up, and specialises in products and services for the industry.
count on the very highest standards in terms of function, reliability and service life every time. We have summarised the products that are already being used in nacelles, towers or the drip loop for you in our new “Special wind energy catalogue”.
No matter which cables our customers choose for their wind turbines, they can
10
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Protection ABB protection devices Component supplier for residential and power plant application ABB has been working for many years, as both a manufacturer and supplier, to offer products and solutions that reduce the environmental impact of energy systems. In a world of ever diminishing resources and soaring energy demand, the focus of ABB’s research lies in developing efficient and sustainable ways to generate, transmit, distribute and use electrical energy. With vast experience in Automation Products, ABB is constantly searching for new ways to expand and enhance existing technologies to meet the needs of its customers. In a society where climate change is becoming an ever stronger argument for increased use of clean energy, such as wind or solar power.
ABB represents the best supplier for OEMs, installers and general contractors, offering a complete portfolio of products to support development of the renewable energy market. For the photovoltaic market, ABB supplies a comprehensive range of high technology products for virtually every residential, commercial and power plant application to grant its customers access to renewable sources of energy. An investment in a solar plant is an investment in and for the future. The profitability calculation derived from the amount invested, term of financing and amortisation is based on factors such as the size and output of the system, climatic conditions and the general conditions arising from the geographical/regional installation location.
Although the risk presented to the systems by lightning, over- and reverse currents and overvoltage can be defined statistically, there are always elements of uncertainty. Therefore, ABB sees integrated solutions for overvoltage protection as an absolute prerequisite. These take the form of triedand-tested components which ensure that the level of income corresponds to the forecasts for your development.
Lightning and overvoltage protection Protection devices for PV installations Cells and inverters are very sensitive to overvoltage and impulse currents, such as switching and lightning surges. The ABB surge arrester range for special DC limits the overvoltage to an acceptable level for the equipment to be protected and prevent damage to installations. Therefore, the risk of financial losses should be taken into account when considering an investment in solar panels. One of the benefits of using SPDs is a better return on investment. Type
Role
Options
Comment
A
Location
DC
Protection of cells
If the distance L1 < 10 m, only OVR PV in A or B is recommended.
Connection to the chassis should be as short and rectilinear as possible. The lightning arrester depending on the environment should be installed in a leak-proof casing.
B
DC
Protection of the inverter input on the DC side
If the distance L1 < 10 m, only OVR PV in A or B is recommended.
Connection to the earthing bar and to the ground of the inverter on the DC side should be as short and rectilinear as possible.
C
AC
Protection of the inverter output on the AC side
Routine installation
Connection to the earthing bar and to the ground of the inverter on the AC side should be as short and rectilinear as possible.
D
AC
AC head protection at the entrance of the building
Routine installation
Connection to the earthing bar should be as short and rectilinear as possible.
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
11
Protection Lightning and overvoltage protection Residential application
Cartridges for maintenance Part number
Voltage
OVRPV40600C
600V
OVRPVMC
600V Neutral
OVRPV40-1000C
600V OVR PV surge arrestor block (A or B)
Selection of surge arresters, DC portion
Current flow capacity
Voltage protection level up (L-L / L-PE)
Surge arrestor location
OVRPV40600P
500 & 600 V
40 kA
2.8 / 1.4 kV
AB
OVRPV40600PTS*
500 & 600 V
40k A
2.8 / 1.4 kV
AB
OVRPV401000P
1000 V
40 kA
3.8 kV
OVRPV401000PTS*
1000 V
40 kA
3.8 kV
TS* : auxillary contact
12
1000V OVR PV surge arrestor block (A or B)
Selection of lightning arresters, AC portion
Inverter U max.
Part number
1000V
Lightning rod
Surge arrestor location
**OVRT13N25255TS*
Yes
D
OVRT21N40275P
Yes
C
AB
**OVRT23N70275sP
No
D
AB
OVRT21N15275P
No
C
Part number
**also available in 1 pole + neutral (1N)
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Protection Lightning and overvoltage protection Power plant application
Surge arrestors for data Part number
Signal Voltage
OVRTC06VP
6V
OVRTC12VP
12V
OVRTC24VP
24V
OVRTC48VP
Selection of surge arresters, DC portion
Current flow capacity
Voltage protection level up (L-L / L-PE)
Surge arrestor location
OVRPV40600P
500 & 600 V
40 kA
2.8 / 1.4 kV
AB
OVRPV40600PTS*
500 & 600 V
40k A
2.8 / 1.4 kV
AB
OVRPV401000P
1000 V
40 kA
3.8 kV
OVRPV401000PTS*
1000 V
40 kA
3.8 kV
TS* : auxillary contact
220V
OVRTC200VP
220V
Selection of lightning arresters, AC portion
Inverter U max.
Part number
48V
OVRTC200FRP
Lightning rod
Surge arrestor location
**OVRT13N25255TS*
Yes
D
OVRT21N40275P
Yes
C
AB
**OVRT23N70275sP
No
D
AB
OVRT21N15275P
No
C
Part number
**also available in 1 pole + neutral (1N)
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
13
Protection 440/500V DC circuit breakers Maximum safety for use in photovoltaic systems ABB’s well established System proM S280 range of MCBs (miniature circuit breakers) has been further extended to include UC (Universal Current versions) which feature the K tripping characteristic which is the optimal solution for the safe protection of cables. A permanent magnet assists in the forced extinguishing of the DC arc. Rated voltage: • 440V Maximum operating voltage: • 500V
Current rating (A)
Icn (kA)
2 pole 440/500V DC
6
6
S282UCK6
10
6
S282UCK10
16
6
S282UCK16
20
6
S282UCK20
25
6
S282UCK25
32
6
S282UCK32
40
6
S282UCK40
50
6
S282UCK50
63
6
S282UCK63
Locking device: Prevents unauthorized operation of the operating lever. Suits 3mm Ø padlock Part number: SA1
800V DC circuit breakers Maximum safety for use in photovoltaic systems The high-performance MCB S800PV-S specially developed for use in photovoltaic systems offers reliable protection for PV modules and lines against reverse currents from defective strings and AC regenerative feedback due to defective inverters. The high demands of PV systems have been taken into consideration in the development of the S800PV-S:
More voltage: Higher nominal voltage range up to 1200VDC (3 pole). Rated continuous current up to 125A.
Non Polarised: Polarity independant design, can be used for string protection.
More accessories: Wide range of accessories, for example for remote switching, fault signalling and external driving.
Locking device: Prevents unauthorized operation of the operating lever. Suits 4mm Ø padlock Part number: S800-PLL
More comfort: Disconnector properties for comfortable switching even under load.
More space: Highly compact dimensions for spacesaving installation on the DIN rail.
Current rating (A)
Icu (kA)
2 pole 800V DC
3 pole 1200V DC
10
5
S802PVS10
S803PVS10
13
5
S802PVS13
S803PVS13
16
5
S802PVS16
S803PVS16
20
5
S802PVS20
S803PVS20
25
5
S802PVS25
S803PVS25
32
5
S802PVS32
S803PVS32
40
5
S802PVS40
S803PVS40
50
5
S802PVS50
S803PVS50
63
5
S802PVS63
S803PVS63
80
5
S802PVS80
S803PVS80
100
5
S802PVS100
S803PVS100
125
5
S802PVS125
S803PVS125
14
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Protection IP65 DC isolator Quick, simple, IP65 DC isolation IP65 rated DC isolation made easy. Simply plug your PV array cables into the isolator, then fit your conduit for the run to the inverter. No more messing around with glands and/or silicone. DC input is pre wired to eliminate polarity errors. Manufactured using premium quality ABB circuit breakers & box and Multi-Contact PV connectors. Benefits • Eliminates polarity errors on input • Genuine Multi-Contact connectors • IP65 • MC4 and MC3 versions • 500V DC & 800V DC models available • Plug and play • Lockable • Unit is supplied complete • Custom versions also available Voltage
Type
10A
16A
20A
32A
500V DC
MC3
XPMC3500VDC/10A
XPMC3500VDC/16A
XPMC3500VDC/20A
XPMC3500VDC/32A
500V DC
MC4
XPMC4500VDC/10A
XPMC4500VDC/16A
XPMC4500VDC/20A
XPMC4500VDC/32A
800V DC
MC3
XPMC3800VDC/10A
XPMC3800VDC/16A
XPMC3800VDC/20A
XPMC3800VDC/32A
800V DC
MC4
XPMC4800VDC/10A
XPMC4800VDC/16A
XPMC4800VDC/20A
XPMC4800VDC/32A
AC rated miniature circuit breakers
Polycarbonate enclosures
6kA C curve, single and 3 pole
IP65 2/4 pole
ABB MCBs satisfy the most common requirements in terms of MCBs, for use in domestic, industrial, and commercial applications. All the MCB´s comply to IEC/ EN 60898 and IEC/EN 60947-2 standards. Type 6 Amp
1 pole
3 pole
S201C06
S203C6
10 Amp
S201C10
S203C10
16 Amp
S201C16
S203C16
20 Amp
S201C20
S203C20
25 Amp
S201C25
S203C25
32 Amp
S201C32
S203C32
Part number
40 Amp
S201C40
S203C40
LE12742
50 Amp
S201C50
S203C50
LA12866
63 Amp
S201C63
S203C63
LE12742.LOCK
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
2/4 Pole 100x160x100 Barrel lock to suit Enclosure & lock (kit)
15
Protection DIN rail mount fuse carriers 600 and 1000V DC, 10 x 38mm fuse 1000V fuse carriers PCF 10DC are the next generation of fuse disconnectors, which comprise the well known qualities from previous versions and offer the following additional advantages:
600V DC fuse carriers
1000V DC fuse carriers
• extraction of entire fuse-link when changing • chamber for spare fuse-link • new type of mounting on the rail and simple replacement • double connection clamp • LED indicator version with light conduit • option of mounting auxiliary devices • sealing possibility Voltage and Rating: 690VAC (32A) 1000VDC (20A) 900VDC (25A) Cable size max: 0.5 to 10mm2/AWG 8 - 20 (solid) Approvals: IEC60947-1, IEC 60947-3, EN60947-1, EN60947-3
Part number
600V DC description
Part number
1000V DC description
VLC10P1
1 pole carrier
PCF10DCP1
1 pole carrier
VLC10P2
2 pole carrier
PCF10DCP2
2 pole carrier
VLC10P3
3 pole carrier
PCF10DCP3
3 pole carrier
PCF10DCP1S
1 pole carrier and LED indicator
PCF10DCP2S
2 pole carrier and LED indicator
PCF10DCP3S
3 pole carrier and LED indicator
PV series fuses 600 and 1000V DC, 10 x 38mm fuse 600V DC fuses Fast acting, high-interrupting capacity, current limiting type fuse, especially designed for DC applications. 1000V DC fuses The short-circuit conditions associated with solar panels do not allow for sufficient current to open a standard fuse in a way that effectively isolates faulted photovoltaic (PV) strings. The new Cooper Bussmann® PV Fuse line provides a full range of protection that traditional fuses cannot.
16
Part number
Rating
Part number
Rating
6 A 600V DC
PV3A10F
3 A 1000V DC
DCM8
8 A 600V DC
PV4A10F
4 A 1000V DC
DCM10
10 A 600V DC
PV6A10F
6 A 1000V DC
DCM12
12 A 600V DC
PV8A10F
8 A 1000V DC
DCM15
15 A 600V DC
PV10A10F
10 A 1000V DC
DCM20
20 A 600V DC
PV12A10F
12 A 1000V DC
DCM25
25 A 600V DC
PV15A10F
15 A 1000V DC
DCM30
30 A 600V DC
PV20A10F
20 A 1000V DC
DCM6
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Protection String protection 1000V DC As PV system designs become larger to maximize return on investments, the need for PV string protection is becoming more common.
No more need to spend hours in the workshop building these units when you could invest your time in more profitable exercises.
We are proud to announce the release of a new string protection system. Available in numerous current ratings, these PV String Fuse Boxes are manufactured with premium components. Fusing is rated at 1000V DC and designed specifically for PV systems.
Benefits • Genuine MultiContact MC4 connectors • 1000V DC rated fuses • 0.6/1kV Lapp cabling • Available in numerous configurations • Plug and play • Unit is supplied complete • One, Two and Three string designs • Custom versions also available
Most DC rated circuit breakers are polarised and are not suitable for string protection, therefore fusing is required.
Current rating (A)
1 String Fuse Box
2 String Fuse Box
4A
XPMC4FUSE1/4A
XPMC4FUSE2/4A
3 String Fuse Box XPMC4FUSE3/4A
6A
XPMC4FUSE1/6A
XPMC4FUSE2/6A
XPMC4FUSE3/6A
8A
XPMC4FUSE1/8A
XPMC4FUSE2/8A
XPMC4FUSE3/8A
10A
XPMC4FUSE1/10A
XPMC4FUSE2/10A
XPMC4FUSE3/10A
12A
XPMC4FUSE1/12A
XPMC4FUSE2/12A
XPMC4FUSE3/12A
15A
XPMC4FUSE1/15A
XPMC4FUSE2/15A
XPMC4FUSE3/15A
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
17
Protection Residual current circuit breakers (RCCB) B Type, DC applications Residual current devices ensure protection of people and installations against fault current to earth and fire risks. An RCD B type is required on the AC side in case of lack of electrical separation between the AC and DC side.
The RCCBs F202 PV B and F204 B are intended for installation of single and three phase PV converters. They protect against fire risks and leakage currents. Other models available, please enquire for more information.
The devices save money and improve global efficiency by using PV converters without an internal insulation transformer.
F200 B type
F200 B selective type
F200 PV B type
For smooth DC earth fault current
For smooth DC earth fault current
For smooth DC earth fault current for PV applications
Function: protection against the effects of sinusoidal alternating, direct pulsating and pulsating DC or smooth DC earth fault currents; protection against indirect contacts and additional protection against direct (with I∆n=30 mA) contacts.
Function: protection against the effects of sinusoidal alternating, direct pulsating and pulsating DC or smooth DC earth fault currents with an intentional tripping delay, which permits to realize the selectivity with downstream instantaneous devices; protection against indirect contacts.
Where an electrical installation includes a PV power supply system without at least simple separation between the AC side and the DC side, an RCD installed to provide fault protection by automatic disconnection of supply should be type B according to IEC 60755.
Rated residual current I∆n mA
Rated Current In A
F204B-40/0.03
30
40
F204B-63/0.03
30
63
F204B-63/0.3
300
63
Part number
Part number F204BS-63/0.3
Rated residual current I∆n mA
Rated Current In A
300
63
Rated residual current I∆n mA
Rated Current In A
F202PVB-25/0.03
30
25
F202PVB-63/0.03
30
63
Part number
AC rated devices Miniature circuit breakers 6kA C curve, single and 3 pole ABB MCBs satisfy the most common requirements in terms of MCBs, for use in domestic, industrial, and commercial applications. All the MCB´s comply to IEC/ EN 60898 and IEC/EN 60947-2 standards.
18
Type 6 Amp
1 pole
3 pole
S201C06
S203C6
10 Amp
S201C10
S203C10
16 Amp
S201C16
S203C16
20 Amp
S201C20
S203C20
25 Amp
S201C25
S203C25
32 Amp
S201C32
S203C32
40 Amp
S201C40
S203C40
50 Amp
S201C50
S203C50
63 Amp
S201C63
S203C63
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
AC rated devices 3 pole disconnectors Easyline series Properties of the EasyLine XLP: • Quick-make operation device • Integrated IP 20 cable termination • IP 30 degree of protection from the front • Replacement compatible to similar types in the market • Voltage measuring from the front • V-0 plastic materials • Easy to install • Easy to snap on DIN rails • Easy to operate • Easy to recycle
Applications of EasyLine fuse protection: • Switchboards • Distribution systems • OEM’s
Part number
Current rating
XLP000
100 Amp
XLP00
160 Amp
XLP1
250 Amp
XLP2
400 Amp
XLP3
630 Amp
IP66 switch isolator Enclosed isolator Suitable for switching and isolating applications where a high level of dust and water ingress protection is required. Padlockable in the OFF and ON positions. Dimensions: 83(W)x167(H)x73(D)mm. Not suitable for switching DC under load.
Part number
Contacts
Current
WSD220
2
20 Amp
WSD232
2
32 Amp
WSD245
2
45 Amp
WSD263
2
63 Amp
WSD420
4
20 Amp
WSD432
4
32 Amp
WSD445
4
45 Amp
WSD463
4
63 Amp
Metering devices for AC ODINsingle 65A ODINsingle is intended for mounting on a DIN rail and is designed in accordance with the ABB Pro M standard. General Features ODINsingle is an active energy, single phase meter for direct metering up to 65A. The LCD display has 6 digits, 6 mm high to ensure easy reading. ODINsingle is made compact, only 2 modules (35 mm) to save space in the installation. A red LED at the front flashes proportionally to the energy consumed. ODINsingle has a temperature range from -25 to +55 (storage +70 °C)
Communication ODINsingle has 3 ways to communicate depending on type. • Display at front • Pulse output (option) • IR interface for serial communication (together with serial communication adapter) Type Approval All ODINsingle types are tested and approved according to MID, EN 50470-1, EN 50470-3, IEC 62052-11 and 62053-21. These standards cover all technical aspects of the meter like climate conditions, electromagnetic compatibility (EMC), electrical requirements, mechanical requirements and accuracy.
Part number OD1065
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Voltage
Current
230 V
65 A
19
Enclosures Plastic IP55 - IP65 Thermoplastic IP55
Part number LE00852
Thermoplastic IP55
Internal dimensions L x W x D (mm) 153 x 110 x 66
Part number LE12644
Polycarbonate IP65
Poles
Dimensions WxHxD (mm)
4
125x180x105
Part number LE12742
LE00854
160 x 135 x 77
LE12646
6
160x180x105
LA12866
LE00856
220 x 170 x 80
LE12650
10
230x180x105
LE12742.LOCK
2/4 Pole 100x160x100 Barrel lock to suit Enclosure & lock (kit)
Amelan速 (PBT) thermoplastic IP67 AMELAN速 has a high resistance to chemicals, e.g. fuels, diluted acids and bases, most watery saline solutions and aliphatic hydrocarbons. The AMAXX enclosure is fitted with captive screws with a double thread for swift opening and closing. With the window opening towards the bottom, the electrician has both hands free, e.g., for measurements or for changing fuses. The window can be locked using a padlock. All external screws are stainless steel. A unique feature is the DIN rail can be pulled out and the large, smooth wiring space makes insertion and connection of cables even more convenient.
Ideal for larger installations, harsh environments or allowing for future expansion of the PV system. Ingress protection IP67 Dimensions 225x130x170mm (WxHxD) 10 pole Cable entry (threaded) 2 x M20 at the top (closed) 2 x M20 at the bottom (closed) 2 x M25 at the top (closed) 2 x M25 at the bottom (closed)
Part number ME910387
Poles 10
Steel Powder coated and stainless steel Lohmeier have a proud tradition of providing high quality installation enclosure systems, with a wide range of metal enclosures, from terminal boxes and wall mounted to floor standing enclosures. Available in powder coated and stainless steel.
20
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Glands Skintop® ST-M Black polyamide cable gland Material: Body: Polyamide
Temperature range: -20oC to +80oC
Supplied with locknut
Metric thread
Protection class: IP 68 Cable Ø range (mm)
53111206
M 12
3.5 – 7
53111216
M 16
4.5 – 10
53111226
M 20
7 – 13
53111236
M 25
9 – 17
53111246
M 32
11 – 21
53111256
M 40
19 – 28
53111266
M 50
27 – 35
53111270C
M 63
34 – 45
Skintop® CLICK Cable glands without locknuts for quick assembly The most innovative cable insertion system on the market for very fast, highly flexible assembly with all the proven properties of our SKINTOP® cable glands in use world-wide. Simply click in - turn to left - turn to right - finished. Result: fixed, centred, strain relief, and IP68 protection in seconds. Material: Body: Special polyamide
Temperature range: -20oC to +100oC
Protection class: IP 68 - 5 bar
Size
Colour
Cable Ø range (mm)
Pack size
53112686
M 16
Light grey
5-9
50
53112882
M 16
Black
5-9
50
53112687
M 20
Light grey
7 - 13
25
53112883
M 20
Black
7 - 13
25
53112688
M 25
Light grey
9 - 17
25
53112884
M 25
Black
9 - 17
25
Part number
Skintop® DIX-M Multiple sealing insert for SKINTOP® metric cable glands Turns the SKINTOP® cable gland into a multiple gland. A sealing ring with several holes is used in place of the inner sealing insert. The SKINTOP® DIX-M multiple sealing insert enables several cables to be fed simultaneously through one gland whilst retaining IP68.
Suits gland
No. of cables x cable Ø mm
53320250
M 20
2x5
53332270
M 32
2x7
53320260
M 20
2x6
53332280
M 32
2x8
53320353
M 20
3 x 5.3
53332290
M 32
2x9
53325260
M 25
2x6
53332370
M 32
3x7
Part number
Part number
No. of Suits cables x gland cable Ø mm
53325350
M 25
3x5
53332380
M 32
3x8
53325360
M 25
3x6
53332460
M 32
4x6
53325370
M 25
3x7
53332470
M 32
4x7
53325450
M 25
4x5
53332560
M 32
5x6
53325540
M 25
5x4
53332460
M 32
4x6
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
21
Terminals Selos WKN Screw connection with universal foot for DIN mounting Selos terminals have a low profile, narrow width, and a universal foot that provides firm seating on the mounting rail, with protection against reverse mounting.
Hardened steel clamping bodies provide vibration-resistant clamping of conductors and current bars, as well as permitting multiple terminations without impairment of connection security.
Feed through terminals
Description
2.5mm2
4mm2
6mm2
10mm2
16mm2
Double 4mm2
Terminal grey
57.503.0055.0
57.504.0055.0
57.506.0055.0
57.510.0155.0
57.516.0155.0
57.404.7055.0
Terminal blue
57.503.0055.6
57.504.0055.6
57.506.0055.6
57.510.0155.6
57.516.0155.6
-
-
57.504.0055.5
-
-
-
-
Terminal red Terminal white
-
57.504.0055.2
-
-
-
-
Terminal black
-
57.504.0055.1
-
-
-
-
End plate grey
07.311.0155.0
07.311.0155.0
07.311.0255.0
07.311.6655.0
07.311.6755.0
07.311.4055.0
Partition grey
07.311.1155.0
07.311.1155.0
07.311.1255.0
07.311.7655.0
07.311.7755.0
07.311.5055.0
Jumper bar
Z7.280.0027.0 (80 poles)
Z7.281.0027.0 (70 poles)
Z7.282.0027.0 (40 poles)
Z7.283.6027.0 (40 poles)
Z7.284.2027.0 (30 poles)
Z7.210.3027.0 (70 poles)
5 x 20 fuse 4mm2
6.3 x 32 fuse 4mm2
6.3 x 32 fuse 10mm2
Double earth 4mm2
Earth 4mm2
Earth 6mm2
Terminal
57.904.5355.0
57.904.6355.0
57.910.5355.0
57.504.9255.0
57.504.9055.0
57.506.9055.0
End plate
Fully enclosed
Fully enclosed
07.311.4155.0
Fully enclosed
Fully enclosed
Fully enclosed
Fused and earth terminals
Description
DIN rail Din rail and end brackets
Description
35 x 7.5mm
35 x 15mm
Plastic
Metal foot
2 metre, non-slotted
98.300.0000.0
-
-
-
2 metre, slotted
98.300.1000.0
98.370.1000.0
-
-
-
-
Z5.522.7453.0
Z5.522.8553.0
End bracket
22
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Accessories Wire ferrules Designed for single insulated V90HT flexible building wire Part number
Wire size (mm2)
Colour
CF050
0.5
White
Pack size (PCS) 500
CF075
0.75
Light blue
500
CF100
1
Red
500
CF150
1.5
Black
500
CF250
2.5
Grey
500
CF400
4
Orange
500
CF600
6
Green
100
CF1000
10
Brown
100
CF1600
16
White
100
CF2500
25
Black
50
Pack size (PCS)
Cable lugs Electro-tin plated high conductivity copper Part number
Cable ties
Wire size (mm2)
Stud size (mm)
S2.5-4
2.5
4
100
S2.5-5
2.5
5
100
S2.5-6
2.5
6
100
S2.5-8
2.5
8
100
S4-5
4
5
100
S4-6
4
6
100
S4-8
4
8
100
S4-10
4
10
100
S6-5
6
5
100
S6-6
6
6
100
S6-8
6
8
100
S6-10
6
10
100
Heat shrink
Insulating tape
Length x Width (mm)
Colour
Pack size
CT102B
100 x 3.2
Black
100
CHSB5BK
Black handypack
5
7
CT143B
150 x 3.6
Black
100
CHSB10BK
Black handypack
10
4.5
ITBK/10
CT194B
203 x 4.8
Black
100
CHSB10RED
Red handypack
10
4.5
NO.15NITTO
CT280BK
300 x 4.8
Black
100
CHSB13BK
Black handypack
12
4
Part number
Part number
Description
CT300HBK
300 x 7.6
Black
100
CHSB13RED
CT370B
385 x 4.8
Black
100
CHSB16BK
CT373B
370 x 7.6
Black
100
CHSB16RED
CT550B
550 x 8
Black
100
CHSB19BK
550 x 13
Black
100
CHSB25BK
Black handypack
CT550HB
Size Length (mm) (mtr)
Red handypack
12
4
Black handypack
16
2.8
Red handypack
16
2.8
Black handypack
19
2.2
25
1.8
Part number ITRP
Description
Length Pack (mtr) size
PVC Rainbow
20
10
PVC Black
20
10
Self Fusing Black
10
1
Other sizes and colours of heatshrink and cable ties also available on request
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
23
Liquid tight IP 68 conduit ROHRflex® PA6 Industrial standard conduit Application: Due to the long life span of PV arrays, Industrial grade conduit should be used to maximise the life of your installation, don’t risk domestic or commercial grade conduit on PV installations.
Colour: Black.
Construction: Internally and externally corrugated PA6 plastic tubing.
Properties: • Oil resistant up to + 80o C • Benzine resistant • Highly resistant to acid and solvents • Free of silicone, cadmium, halogen • Flame retardant, self-extinguishing • UV-resistant
Temperature range: -30oC to +100oC
Protection class: Conduit: IP68 Fittings: IP65 - IP67
RORHflex® PA6 Conduit Part number
Conduit size
Outer Ø mm
Inner Ø mm
Coil length mtrs
0233.202.010
M12
13.0
10.0
50m
0233.202.012
M16
15.8
12.0
50m
0233.202.016
M20
21.2
16.5
50m
0233.202.023
M25
28.5
23.0
50m
0233.202.029
M32
34.5
29.0
25m
0233.202.036
M40
42.5
36.0
25m
0233.202.048
M50
54.5
48.0
25m
FLEXAquick fittings - no assembly tools required! Part number
RQG1-M (Straight - IP 66) Part number
For conduit size Thread size
Pack qty
For conduit size Thread size
Pack qty
RQW1-M (IP 65)
5020.055.214
M12
M16
50
5020.051.212
M12
M12
50
5020.055.216
M16
M16
50
5020.051.218
M16
M16
50
5020.055.218
M16
M20
50
5020.051.222
M20
M20
50
5020.055.220
M20
M20
50
RQB90-M (90o Bend - IP 67)
5020.055.222
M20
M25
50
5103.013.216
M16
M12
50
5020.055.225
M25
M25
25
5103.015.220
M16
M20
50
5020.055.228
M25
M32
25
5103.021.220
M20
M20
50
5020.055.232
M30
M32
25
5103.028.225
M25
M25
25
25
5103.034.232
M32
M32
25
10
5103.042.240
M40
M40
10
5103.054.250
M50
M50
5
5101.013.216
M16
M12
50
5101.021.220
M20
M20
50
5101.042.240
M 40
M 40
10
5020.055.240 5020.055.250
M40 M50
M40 M50
RQB1 45-M (45o Bend - IP 65) Mounting clip - RQS (One piece clamp) Part number
For conduit size
Pack qty
5030.020.209
M12
50
5030.020.211
M16
50
5030.020.216
M20
25
Part number
5030.020.221
M25
25
5311 9100
M12
100
5030.020.229
M32
25
5311 9110
M16
100
5030.020.236
M40
25
5311 9120
M20
100
5030.020.248
M50
10
5311 9130
M25
100
Locknuts to suit fittings Thread size
Pack qty
Other industrial conduit types also available
24
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Electric vehicles E-vehicles Mennekes develops charging systems Everyone agrees that the future belongs to electric drives. The paths for developing electric cars were defined in the master plan of the German Federal Government, the political committees of the EU as well as in the USA and Asia. The German Federal Government even plans to turn Germany into the leading European nation with respect to electromobility by 2020. The German Manager Magazine estimates that there will be over 2.5 million electric cars on the roads in Germany by 2020. According to Ferdinand Dudenhöffer, director of the Center of Automotive Research at the FH Gelsenkirchen, each car sold in the year 2025 will have at least a hybrid drive. This is why all leading vehicle manufacturers are working at full speed to develop electric cars for serial production. Solutions for powerful compact batteries are being developed at the same time.
Decisive for the mass acceptance of electric cars is the development of a corresponding charging infrastructure to be able to recharge the electric cars.
The most important prerequisite for this is above all a uniform charge socket and the corresponding plug. As a specialist for plug-type connections, MENNEKES contributes its know-how to this futureoriented business field.
Battery connector 2/3 pole 630V 330A power contacts and 4 pole 250V 16A pilot contacts The SEM battery connector from MultiContact is suitable for the internal connection from battery to control unit or motor, also suitable for external connection to charging stations. Features: • Non interchangeable 2 pole and 3 pole connector • Safe, lockable connection with fixing bracket • Connector can be coded • Silver plated • IP65 • Touch protected • -40°C to +150°C
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
25
Energy management Lighting control module Intelligent lighting Climate change is now an ethical issue for most people and their governments world-wide. And for companies serious about corporate responsibility as well as cost reduction, the Smart Building is now a priority. Intelligent building controls significantly reduces energy consumption and carbon footprint. Building controls work together, autonomously or centrally, to realise substantial reductions in energy consumption from monitoring and control of the building environment. Constant Daylight (Daylight Harvesting) The DURA-TECH DLC100/200 lighting control module from DKSH has Constant Daylight (Daylight Harvesting) and dimming capabilities, helping to make your commercial lighting more energy-efficient While there are many strands to carbon footprint reduction, commercial lighting is probably the most visible and emblematic of the struggle. We all know that changing to low energy light bulbs can reduce energy consumption. But such lighting is still often left on when rooms are empty, dramatically illustrated by any night-time city skyline. Plus there is the residual heat generated which causes extra load on a facility’s air conditioning plant. Constant Daylight Simple timers can reduce some of this overhead, as can presence detection (which automatically switches lights on and off when someone enters/leaves a room) or absence detection (which requires manual light activation but automatically switch off when someone leaves.) But now there is a smarter and greener adjunct to these tools: Constant Daylight (also known as Daylight Harvesting.)
26
The idea behind Constant Daylight/Daylight Harvesting is simple: using a combination of presence/absence detectors, light level detection and a lighting controller. The lighting of a room adjusts to complement current natural light, producing a comfortable, constant lighting load which is switched off when occupancy has ceased. Using less power So effective is Constant Daylight that in a recent installation, on a typically overcast spring day, the ambient light level in a classroom of 15 sq m at a steady 300 lux used 60 per cent less power than conventional lighting. And in some cases, a bright, sunny day enables Constant Daylight to eliminate artificial light use altogether. Obviously Constant Daylight cannot be used at night, but presence/ absence detection means that full lighting is only used when a room is occupied, changing your building to a low-carbon gap in the night skyline.
That’s why Constant Daylight/Daylight Harvesting is a powerful and cost effective tool in your quest for ever greater carbon footprint reductions.
Wieland GESIS modular wiring Using the Wieland GESIS wiring system dramatically reduce installations costs. The GESIS system not only provides control, but also distributes AC power around the building. Simply plug in the DLC100/200 Light Control Module with Daylight Harvesting to the GESIS cable, and then connect lights using pre-made leads and connectors, it’s that simple.
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Energy management Lighting control module Intelligent lighting Features
DLC100
DLC200
DIN Rail Mounting
Yes
Yes
Busbar Mounting
Yes
Yes
Slab Mounting
Yes
Yes
Size mm(w x l x h) Enclosure Material Warranty Input Voltage
200x130x35 295x185x35 Steel
Steel
3 Years
3 Years
110-240v
110-240v
Input
GST18i3
GST18i3
Outputs
GST18i4
GST18i6
Max Load
10A
10A
Load Incandescent
10A
10A
Load Fluorescent
10A
10A
Load Compact Fluorescent
10A
10A
Outputs Switching
2
3
Outputs Dimming (1-10v)
0
2
Outputs Dimming (DSI)
0
2
Outputs Dimming (Dali)
0
2
Ballasts per channel
-
64
GST18i3
GST18i3
Inputs Presence Detectors
8
8
No
Yes
Switches
2
2
Key Switch
2
2
Daylight Sensor
8
8
Presence Detection
Yes
Yes
Absence Detection
Yes
Yes
Daylight Linking
Yes
Yes
Constant Daylight
No
Yes
Switch/Dim
No
Yes
Integral Corridor Hold
Yes
Yes
Dusk til Dawn
Yes
Yes
Integral Emergency Test
Yes
Yes
Dusk til Dawn
Yes
Yes
Integral Emergency Test
Yes
Yes
2 Stage Timeout
The DLS1000 Sensor Head is a companion product to the Lighting Controller and is used for movement and daylight sensing in lighting applications.
The DLC100/200 is â&#x20AC;&#x2DC;self configuringâ&#x20AC;&#x2122; with easy to set-up parameters via an intelligent configuration interface that reduces costly commissioning time and is easily configured by installing electricians and does not need third party commissioning engineers.
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
27
Energy management GST 18i3 World leading 3 pole soft wiring system for lighting & power applications The backbone of the gesis® connector system is the 2 pole & Earth, GST18i3. Rated at 250V, 20A, they are approved for use as installation couplers to: AS/NZS 61535. Preassembled PVC sheathed cables
Extension Cable Female – Male Length 1 mtr
3G2.5 Black 92.238.1000.1
Connection Cable Female - free end Length 1 mtr
3G2.5 Black 92.238.1003.1
Connection Cable Male – free end Length 1 mtr
3G2.5 Black 92.238.1004.1
2 mtr
92.238.2000.1
2 mtr
92.238.2003.1
2 mtr
92.238.2004.1
3 mtr
92.238.3000.1
3 mtr
92.238.3003.1
3 mtr
92.238.3004.1
4 mtr
92.238.4000.1
4 mtr
92.238.4003.1
4 mtr
92.238.4004.1
5 mtr
92.238.5000.1
5 mtr
92.238.5003.1
5 mtr
92.238.5004.1
6 mtr
92.238.6000.1
6 mtr
92.238.6003.1
6 mtr
92.238.6004.1
7 mtr
92.238.7000.1
7 mtr
92.238.7003.1
7 mtr
92.238.7004.1
8 mtr
92.238.8000.1
8 mtr
92.238.8003.1
8 mtr
92.238.8004.1
GST 18i4 World leading 4 pole soft wiring system for lighting applications
Preassembled PVC sheathed cables
Extension Cable Female – Male
Connection Cable Female - free end
Connection Cable Male – free end
Length
Length
Length
4G1.5 Black
4G1.5 Black
4G1.5 Black
1 mtr
92.207.1000.1
1 mtr
92.207.1003.1
1 mtr
92.207.1004.1
2 mtr
92.207.2000.1
2 mtr
92.207.2003.1
2 mtr
92.207.2004.1
3 mtr
92.207.3000.1
3 mtr
92.207.3003.1
3 mtr
92.207.3004.1
4 mtr
92.207.4000.1
4 mtr
92.207.4003.1
4 mtr
92.207.4004.1
5 mtr
92.207.5000.1
5 mtr
92.207.5003.1
5 mtr
92.207.5004.1
6 mtr
92.207.6000.1
6 mtr
92.207.6003.1
6 mtr
92.207.6004.1
7 mtr
92.207.7000.1
7 mtr
92.207.7003.1
7 mtr
92.207.7004.1
8 mtr
92.207.8000.1
8 mtr
92.207.8003.1
8 mtr
92.207.8004.1
28
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Energy management GST 18i6 World recognised 6 pole soft wiring system for power & intelligent building automation 6 pole GST18 connectors are commonly used to connect luminaires into lighting circuits. Typically the connector is used with Lighting Control Modules where
the 6 pole configuration suits the dimming application (Switched Active, Earth, Neutral, Permanent Active for the emergency circuit, and the dimming pair).
Preassembled Halogen-free sheathed cables
Extension Cable Female â&#x20AC;&#x201C; Male
Connection Cable Female - free end
Connection Cable Male â&#x20AC;&#x201C; free end
Length
Length
Length
6G1.5 Black
6G1.5 Black
6G1.5 Black
1 mtr
99.411.0028.0
1 mtr
99.431.0028.0
1 mtr
99.451.0028.0
2 mtr
99.412.0028.0
2 mtr
99.432.0028.0
2 mtr
99.452.0028.0
3 mtr
99.413.0028.0
3 mtr
99.433.0028.0
3 mtr
99.453.0028.0
4 mtr
99.414.0028.0
4 mtr
99.434.0028.0
4 mtr
99.454.0028.0
5 mtr
99.415.0028.0
5 mtr
99.435.0028.0
5 mtr
99.455.0028.0
6 mtr
99.416.0028.0
6 mtr
99.436.0028.0
6 mtr
99.456.0028.0
7 mtr
99.417.0028.0
7 mtr
99.437.0028.0
7 mtr
99.457.0028.0
8 mtr
99.418.0028.0
8 mtr
99.438.0028.0
8 mtr
99.458.0028.0
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
29
Photovoltaic Manufacturing Performance Materials Materials for the manufacturing of Photovoltaics DKSH Australia’s Performance Materials business unit can supply a wide range of key intermediates and innovative products for the photovoltaic manufacturing industry, including: • Speciality chemicals for the production of Dye Sensitised Solar Cells, including ruthenium dyes, titania pastes, electrolytes and ionic liquids. • PEDOT/PSS based transparent, flexible and conductive polymers. • Charge generation and transportation materials. • Firing pastes. • Ultra weather resistant coatings for front- and back-sheet films. • High-performance cleaners for PV substrates, thin-films and glasses.
Organic photovoltaic cells
Thick-film cells
High-tech products and chemicals as holeinjection and electron-acceptor materials for organic photovoltaic cells: • Silver frontside firing paste • Silver backside firing paste • Aluminium backside firing paste • Silver/aluminium mixture firing paste
Specialised range of materials for the production of mono- and multicrystalline thick film silicon wafer-based cells: • Silver frontside firing paste. • Silver backside firing paste. • Aluminium backside firing paste. • Silver/aluminium mixture firing paste.
Photovoltaic module assembling
Dye-sensitised solar cells
Front and backsheet films
High-performance cleaners for photovoltaic substrates, thin-films and glasses: • Ready to use, low foaming cleaners. • Industry specified for efficient in-line cleaning. • Effective debris removal. • Residual free rinsing. • Maximized manufacturing yield.
Selected specialty chemicals for the production of dye sensitised solar cells: • Ruthenium dyes. • Iron dyes. • Screen printing and spin coating titania pastes for active titanium-dioxide layers. • Iodide electrolytes and ionic liquids. • Platinum catalyst paint and screen printing paste.
Ultra weather resistant coating for front and backsheet films or photovoltaic glass: • Acrylic, non-fluorinated polymer with UV absorbing functional groups. • Photocatalytic, super-hydrophilic and anti-reflective coating solution.
30
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
Biomass energy Environmental Technologies Integrated process design, engineering and after sales services DKSH Environmental Technologies leads the way in proven European equipment and solutions for renewable energy usage of solid waste streams. Focusing on high end and robust technologies we offer machines that prepare solid waste streams for alternative energy generation, such as alternative waste treatment plants,
AWT, residue derived fuel plants and composting.
RTT sorting RTTâ&#x20AC;&#x2122;s UniSort near infra red sorters are an essential step in turning waste streams into reliable fuel sources. Being able to identify nearly all organic compositions, it enables engineering of the calorific value as well as removes undesired materials such as PVC.
Matthiessen bag opening In order to free materials for sorting, composting or RDF generation, it is necessary to open the plastic bags that the typical household waste and commercial waste is presented to a plant. The Matthiessen bag opener is one of the most reliable machines for this job with up to 50 tonnes per hour throughput.
With many years of experience in the engineering field, DKSH can offer equipment solutions as well as integrated process design, engineering and after sales services.
Size reduction of wood, plastics, paper, and mixed waste Size reduction is the key to turning solid waste streams into fractions that can be utilised for energy generation. DKSH offers a range of machines from HAAS Pre-crushers and hammermills, to Weima single shaft shredders, fast and slow. Both manufacturers have established themselves as leading suppliers in Europe.
Instrumentation, Life Sciences and Laboratory Products Equipment and consumables for testing and analysis
HSM baling To reduce transport costs, the fuel as well as recyclables derived from alternative waste processes are baled in fully automatic channel bale presses. HSM is a leading German machine supplier offering high durability and quality and DKSH can offer reference sites in Australia and New Zealand and fully trained service back up.
DKSH Instrumentation, Life Sciences and Laboratory Products provide the scientific community with a range of high quality consumables, labware and specialised instrumentation products and value-added services. Our Analytical Instrumentation group provides specialised analytical instrumentation for environmental testing, food and beverage, materials science, mining and minerals, petrochemical, plastics and pharmaceuticals.
DKSH Australia Pty. Ltd., 14-17 Dansu Court, Hallam VIC 3803, Australia. Freecall 1800 010 113, Fax (03) 9554 6677, www.dksh.com.au
31
DKSH Australia Pty. Ltd. 14-17 Dansu Court, Hallam VIC 3803, Australia www.dksh.com/australia
Customer Service: S.A. Customers: W.A. Customers:
1800 010 113 (08) 8440 1300 (08) 6254 5900
Fax: (03) 9554 6677 Fax: (08) 8241 5134 Fax: (08) 9277 8755