2 minute read

Product range.

Impulse Systems.

The air distribution principle for horizontal Impulse Systems is based on passive thermal displacement where the air is supplied at a lower temperature in relation to the air in the room.

Impulse Systems are especially suited for offices, schools, restaurants, laboratories and other applications requiring mixing ventilation and for factory premises with room heights of 10-20 ft for cooling only. They are available in the form of round (Ø), half-round (D), or quarter-round (½D) ducts.

Inject and DireJet Systems.

KE Fibertec markets two products for high impulse ventilation: the Inject System and the DireJet System. Both these systems can be produced in the form of round (Ø), half-round (D), or quarter-round (½D) ducts.

The Inject System comprises groups of holes, small (Inject) or large (Inject XL) in the fabric duct, while the DireJet System comprises rows of conical nozzles specifically for 100% active, directional air delivery.

Both the Inject System and DireJet System can be regarded as high impulse systems for mixing ventilation and can be used for cooling, ventilation, and heating.

Inject Flex Systems.

DireJet System

Inject Flex is a family of multiple sized laser cut holes for the Inject fabric duct. This range of sizes will allow us to design for the optimum air delivery for the application.

The Inject Flex holes are available in multiple patterns and orientations to meet design needs and can be configured to perform in soundsensitive environments.

The Inject Systems are available in various permeabilities and hanging systems with hold-open and/or tensioning devices.

• Air flow through one hole ranges from 0.3 - 0.6 CFM at 0.5 inWG

• Best used where medium to short throws are required

• Mostly used in medium throw premises

• Air flow through one hole ranges from 18 – 76 CFM at 0.5 inWG

• Mostly used in long throw premises with high ceilings

Suspension systems.

KE Fibertec’s fabric duct systems can be supplied with different suspension systems - cable for round ducts or the Safetrack system for round, half-round or quarterround ducts.

What all the suspension systems have in common is that they can be fitted to any type of ceiling and are supplied cut to the same length as the fabric duct. They are also packaged with the necessary accessories and a specific label indicating where they are meant to be installed.

Safetrack Hold Open Systems.

Safe 360

The Safe 360 system consists of removable rings per 20” or 3’. The stainless steel rings are locked with velcro inside the ducts so that they can easily be removed for washing.. The ducts will keep looking inflated, and it is our best solution if popping is a big problem.

Dual Arch

Dual Arch mounting brackets utilize the stability of double rails and at the same time they are quick and easy to install. Large fabric ducts will be stably suspended both with and without air and installation time is reduced considerably as the ducts are mounted in a single ceiling rail.

SafeStretch Tensioning System

The SafeStretch® System is easy to install and basically consists of two tensioning devices - a fastening section at the duct inlet and a tightening device at the bottom that creates the necessary inflation of the duct.