Low Voltage Electrical Appliance “Right Quality, Right Price”
International Catalogue 2009
Delixi Electric: Who are we
A global company at your service Delixi was founded in 1984 in Zhejiang province with sales over 1,5BMâ‚Ź, employing more than 15000 people. Delixi created an international Joint Venture in November 2007,named Delixi Electric LTD,in order to serve you worldwide,with core LV products having the right quality at the right price. Our products are designed for Residential / Building / Energy / infrastructure and Industrial markets . Delixi Electric employs 5200 people world wide.
A reliable company serving you with reliable product Dedicated R&D center International quality control of suppliers International quality control of plants Fully automatized distribution center Network of recognized 600 distributors world wide Clear warranty policy
Reliable quality
For more details, please contact your local Delixi Electric Company. You can trust 100% our products. We offer you a 18 months warranty. During this period of time, we will replace any defected product you may have, provided the responsibility is ours.
A company to serve you where you are
We set up companies in many countries in order to deliver best in class local availability and support . Delixi Elecric China
Delixi Elecric Austral Africa
Delixi Electric South East Europe
Delixi Liushi Industrial Park,Yueqing, Zhejiang,P.R.China Post Code:325604 www.delixi-electric.com
Canon Crescan Drive , Roodekop Germiston, 1400 PO Box 13151 , Elspark, 1418 Mobile : +27 (0) 836438898 www.delixi-electric.co.za Contact : Vicky HATTINGH vicky@delixi-electric.co.za
20 Tsar Samuil str . , 1rst Floor Triaditsa Municipality Sofia Bulgaria Contact : Doychin ZAHARINOV Mobile : +359 885 750 232 doychin.zaharinov@delixi-electric-see.com
Delixi Electric Middle-East
Delixi Electric West Africa
Delixi Electric Pakistan
RAK Free trade zone PO BOX 10559 Ras El Khaima United Arab Emirates Tel : +971 ( 7 ) 244 47 27 Fax : + 971 ( 7 ) 244 27 22 delixi-electric.gulf@delanme.com Contact : Raja BHAUMIK Mobile : +971 ( 50 ) 657 1056 raja@delanme.com
1 Tunde Gaffar Close Off Adeniyi Jones Ikeja Lagos Nigeria Fax : + 234 2703941 Contact : Chidiebere NWORGU Mobile : +234 703 41 111 30 chidiebere.Nworgu@delixi-electric.com
73 / B / 3 , Race View,Jail Road, Lahore, 54000, Pakistan Tel 0092 - 42 - 7570412 / 7570443 , extension 100/103 Fax 0092 - 42 - 7570443 , extension 108 Contact : Syed Sohail IDREES Mobile : 0092 -3028489564 s.idrees@delixi-electric.com
Delixi Electric Marocco 213 Centre Yousra Rond-point d’Europe Casablanca, Maroc tel : +212 (0) 22 268 161 Fax : +212 (0) 22 491342 Contact : Hicham MOUKI Mobile : +212 (0) 61 100 849 hmouki@delixielectric.ma
Delixi Electric South East Asia
Delixi Electric Israel
P.O.Box 7567 Pejabat Post Besar Shah Alam 40720 Shah Alam Selangor Darul Ehsan Tel:03- 78809564 Fax: 03-78809540 Contact: Ellis Lee Email : ellis.lee@delixi-electric.com
Industrial park cible Hamelaha st.22 Rosh ha-aiyn Israel tel:+972546798718 Contact : Hayim COHEN email:hayim.cohen@delixi-electric.co.il
Delixi Electric Saudi Arabia
Delixi Electric Argentina
Delixi Electric Egypt
Contact : Mohkam Sheikh Mobile : +966050269801
Contact : Damian Cattaino Mobile : +54111545658952
Contact : Mohamed Nagy Mobile 20(0) 100705454
Product Panorama Power Distribution
Industry Control
Contents MCB Miniature Circuit Breakers CDB6a 18mm Miniature Circuit Breakers
1
CDB6L 18mm Miniature Circuit Breakers
3
CDB6N 18mm Miniature Circuit Breakers
5
CDB6&CDB6LE Electrical Auxiliaries
7
CDB17 Miniature Circuit Breakers
8
CDB3 Phase-neutral Circuit Breakers
10
CDB2 27mm Miniature Circuit Breakers
11
CDB5 Switch Disconnectors
13
RCBO Residual Current Operated Circuit Breakers With Integral Overcurrent Protection CDB6LE Electronic Type Residual Current Operated Circuit Breakers
15
CDB3LE Electronic Type Residual Current Operated Circuit Breakers
17
CDB2LE Electronic Type Residual Current Operated Circuit Breakers
18
CDB7LSP Electronic Type Residual Current Operated Circuit Breakers
20
RCCB Residual Current Operated Circuit Breakers Without Overcurrent Protection CDL7 Electromagnetic Type Residual Current Switches
21
Surge Protector CDY1 Surge Protective Devices
22
MCB Distribution Board CDPZ50 Distribution Box
25
Meter DDS607 Single-phase Electronic Watt-hour Meters
27
MCCB Moulded Case Circuit Breakers CDM1 Moulded Case Circuit Breakers
29
ELCB Earth-leakage Circuit Breakers CDM1L Moulded Case Circuit Breakers With Electronic Type Residual Current Operated Protection
36
ACB Air Circuit Breaker CDW7 Air Circuit Breaker
42
Contactors CDC17 AC Contactor
61
Relays CDR17 Thermal overload relays
70
Current Transformer LMK Current Transformer
73
Fuse RT16 Fuse
76
RT18 Fuse
78
Power Distribution Box JXF Power Distribution Box
80
Control Signal LD11 Series of indicator light
82
LAY3 Serie of pushbuttons
86
LAY7 Serie of pushbuttons
88
LAY8 Serie of pushbuttons
93
Pannel Meter 72 Series Pannel Meter
96
96 Series Pannel Meter
98
Voltage Stabilizer TND Voltage Stabilizer
100
Nylon Lock Nylon Cable Ties Series
102
CDB6a Standard: IEC 60898-1 IEC 60947-2 Trip Curve: B, C and D curves Breaking Capacity: 3000A
Function
CDB6a miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation
Description
Technical data Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A Rated voltage: 230/400V AC Breaking capacity Rate current
Breaking capacity Icn (A)
Type
Poles
Voltage (V)
1-63A
3000
B
1P 2P, 3P, 4P 1P 2P, 3P, 4P 1P 2P, 3P, 4P
230 400 230 400 230 400
C D
Tropicalization: treatment 2 Protection degree: 2 Connection: up to 25mm2 cables Tripping curves: B curve: the magnetic release operates between 3 and 5 In C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In 35 mm standard DIN rail mounting
Standard and certification IEC 60898-1 KEMA, CB
IEC 60947-2
Overall dimensions Unit:mm
Delixi Electric
1
CDB6a Standard: IEC 60898-1 IEC 60947-2 Trip Curve: B, C and D curves Breaking Capacity: 3000A Type
Rating Width (A) (in mod.of 9mm)
Reference B curve C curve
D curve
1P
1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63
CDB6a1B1 CDB6a1B3 CDB6a1B6 CDB6a1B10 CDB6a1B16 CDB6a1B20 CDB6a1B25 CDB6a1B32 CDB6a1B40 CDB6a1B50 CDB6a1B63 CDB6a2B1 CDB6a2B3 CDB6a2B6 CDB6a2B10 CDB6a2B16 CDB6a2B20 CDB6a2B25 CDB6a2B32 CDB6a2B40 CDB6a2B50 CDB6a2B63 CDB6a3B1 CDB6a3B3 CDB6a3B6 CDB6a3B10 CDB6a3B16 CDB6a3B20 CDB6a3B25 CDB6a3B32 CDB6a3B40 CDB6a3B50 CDB6a3B63 CDB6a4B1 CDB6a4B3 CDB6a4B6 CDB6a4B10 CDB6a4B16 CDB6a4B20 CDB6a4B25 CDB6a4B32 CDB6a4B40 CDB6a4B50 CDB6a4B63
CDB6a1D1 CDB6a1D3 CDB6a1D6 CDB6a1D10 CDB6a1D16 CDB6a1D20 CDB6a1D25 CDB6a1D32 CDB6a1D40 CDB6a1D50 CDB6a1D63 CDB6a2D1 CDB6a2D3 CDB6a2D6 CDB6a2D10 CDB6a2D16 CDB6a2D20 CDB6a2D25 CDB6a2D32 CDB6a2D40 CDB6a2D50 CDB6a2D63 CDB6a3D1 CDB6a3D3 CDB6a3D6 CDB6a3D10 CDB6a3D16 CDB6a3D20 CDB6a3D25 CDB6a3D32 CDB6a3D40 CDB6a3D50 CDB6a3D63 CDB6a4D1 CDB6a4D3 CDB6a4D6 CDB6a4D10 CDB6a4D16 CDB6a4D20 CDB6a4D25 CDB6a4D32 CDB6a4D40 CDB6a4D50 CDB6a4D63
2P
3P
4P
2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8
CDB6a1C1 CDB6a1C3 CDB6a1C6 CDB6a1C10 CDB6a1C16 CDB6a1C20 CDB6a1C25 CDB6a1C32 CDB6a1C40 CDB6a1C50 CDB6a1C63 CDB6a2C1 CDB6a2C3 CDB6a2C6 CDB6a2C10 CDB6a2C16 CDB6a2C20 CDB6a2C25 CDB6a2C32 CDB6a2C40 CDB6a2C50 CDB6a2C63 CDB6a3C1 CDB6a3C3 CDB6a3C6 CDB6a3C10 CDB6a3C16 CDB6a3C20 CDB6a3C25 CDB6a3C32 CDB6a3C40 CDB6a3C50 CDB6a3C63 CDB6a4C1 CDB6a4C3 CDB6a4C6 CDB6a4C10 CDB6a4C16 CDB6a4C20 CDB6a4C25 CDB6a4C32 CDB6a4C40 CDB6a4C50 CDB6a4C63
Tripping Curve
B
2
C
D
Delixi Electric
CDB6L Standard: IEC 60947-2 IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500A
Function
CDB6L miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation
Description
Technical data Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A Rated voltage: 230/400V AC Breaking capacity: Type
Poles
Rate current
Breaking capacity Icn (A)
Voltage (V)
B
1P
1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A
4500 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500 4500
230 400 230 400 230 400 230 400 230 400 230 400
2P, 3P, 4P C
1P 2P, 3P, 4P
D
1P 2P, 3P, 4P
Tropicalization: treatment 2 Protection degree: 2 Connection: up to 25mm2 cables Tripping curves: B curve: the magnetic release operates between 3 and 5 In C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In 35 mm standard DIN rail mounting
Standard and certification IEC 60947-2 IEC 60898-1 KEMA, CB
Overall dimensions Unit:mm
Delixi Electric
3
CDB6L Standard: IEC 60947-2 IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 4500A Type
Rating (A)
Width Reference (in mod.of 9mm) B curve
1P
1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63
2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8
2P
3P
4P
C curve CDB6L1C1 CDB6L1C3 CDB6L1C6 CDB6L1C10 CDB6L1C16 CDB6L1C20 CDB6L1C25 CDB6L1C32 CDB6L1C40 CDB6L1C50 CDB6L1C63 CDB6L2C1 CDB6L2C3 CDB6L2C6 CDB6L2C10 CDB6L2C16 CDB6L2C20 CDB6L2C25 CDB6L2C32 CDB6L2C40 CDB6L2C50 CDB6L2C63 CDB6L3C1 CDB6L3C3 CDB6L3C6 CDB6L3C10 CDB6L3C16 CDB6L3C20 CDB6L3C25 CDB6L3C32 CDB6L3C40 CDB6L3C50 CDB6L3C63 CDB6L4C1 CDB6L4C3 CDB6L4C6 CDB6L4C10 CDB6L4C16 CDB6L4C20 CDB6L4C25 CDB6L4C32 CDB6L4C40 CDB6L4C50 CDB6L4C63
CDB6L1B1 CDB6L1B3 CDB6L1B6 CDB6L1B10 CDB6L1B16 CDB6L1B20 CDB6L1B25 CDB6L1B32 CDB6L1B40 CDB6L1B50 CDB6L1B63 CDB6L2B1 CDB6L2B3 CDB6L2B6 CDB6L2B10 CDB6L2B16 CDB6L2B20 CDB6L2B25 CDB6L2B32 CDB6L2B40 CDB6L2B50 CDB6L2B63 CDB6L3B1 CDB6L3B3 CDB6L3B6 CDB6L3B10 CDB6L3B16 CDB6L3B20 CDB6L3B25 CDB6L3B32 CDB6L3B40 CDB6L3B50 CDB6L3B63 CDB6L4B1 CDB6L4B3 CDB6L4B6 CDB6L4B10 CDB6L4B16 CDB6L4B20 CDB6L4B25 CDB6L4B32 CDB6L4B40 CDB6L4B50 CDB6L4B63
D curve CDB6L1D1 CDB6L1D3 CDB6L1D6 CDB6L1D10 CDB6L1D16 CDB6L1D20 CDB6L1D25 CDB6L1D32 CDB6L1D40 CDB6L1D50 CDB6L1D63 CDB6L2D1 CDB6L2D3 CDB6L2D6 CDB6L2D10 CDB6L2D16 CDB6L2D20 CDB6L2D25 CDB6L2D32 CDB6L2D40 CDB6L2D50 CDB6L2D63 CDB6L3D1 CDB6L3D3 CDB6L3D6 CDB6L3D10 CDB6L3D16 CDB6L3D20 CDB6L3D25 CDB6L3D32 CDB6L3D40 CDB6L3D50 CDB6L3D63 CDB6L4D1 CDB6L4D3 CDB6L4D6 CDB6L4D10 CDB6L4D16 CDB6L4D20 CDB6L4D25 CDB6L4D32 CDB6L4D40 CDB6L4D50 CDB6L4D63
Tripping Curve
B
4
C
D
Delixi Electric
CDB6N Standard: IEC 60947-2 IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 6000A
Function
CDB6N miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation
Description
Technical data Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A Rated voltage: 230/400V AC Breaking capacity: Type
Poles
Rate current
Breaking capacity Icn (A)
Voltage (V)
B
1P
1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A 1-40A 50A, 63A
6000 4500 6000 4500 6000 4500 6000 4500 6000 4500 6000 4500
230 400 230 400 230 400 230 400 230 400 230 400
2P, 3P, 4P C
1P 2P, 3P, 4P
D
1P 2P, 3P, 4P
Tropicalization: treatment 2 Protection degree: 2 Connection: up to 25mm2 cables Tripping curves: B curve: the magnetic release operates between 3 and 5 In C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In 35 mm standard DIN rail mounting
Standard and certification IEC 60947-2 IEC 60898-1 KEMA, CB
Overall dimensions Unit:mm
Delixi Electric
5
CDB6N Standard: IEC 60947-2 IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 6000A Type
Rating Width Reference (A) (in mod.of 9mm) B curve
C curve
D curve
1P
1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63
CDB6N1C1 CDB6N1C3 CDB6N1C6 CDB6N1C10 CDB6N1C16 CDB6N1C20 CDB6N1C25 CDB6N1C32 CDB6N1C40 CDB6N1C50 CDB6N1C63 CDB6N2C1 CDB6N2C3 CDB6N2C6 CDB6N2C10 CDB6N2C16 CDB6N2C20 CDB6N2C25 CDB6N2C32 CDB6N2C40 CDB6N2C50 CDB6N2C63 CDB6N3C1 CDB6N3C3 CDB6N3C6 CDB6N3C10 CDB6N3C16 CDB6N3C20 CDB6N3C25 CDB6N3C32 CDB6N3C40 CDB6N3C50 CDB6N3C63 CDB6N4C1 CDB6N4C3 CDB6N4C6 CDB6N4C10 CDB6N4C16 CDB6N4C20 CDB6N4C25 CDB6N4C32 CDB6N4C40 CDB6N4C50 CDB6N4C63
CDB6N1D1 CDB6N1D3 CDB6N1D6 CDB6N1D10 CDB6N1D16 CDB6N1D20 CDB6N1D25 CDB6N1D32 CDB6N1D40 CDB6N1D50 CDB6N1D63 CDB6N2D1 CDB6N2D3 CDB6N2D6 CDB6N2D10 CDB6N2D16 CDB6N2D20 CDB6N2D25 CDB6N2D32 CDB6N2D40 CDB6N2D50 CDB6N2D63 CDB6N3D1 CDB6N3D3 CDB6N3D6 CDB6N3D10 CDB6N3D16 CDB6N3D20 CDB6N3D25 CDB6N3D32 CDB6N3D40 CDB6N3D50 CDB6N3D63 CDB6N4D1 CDB6N4D3 CDB6N4D6 CDB6N4D10 CDB6N4D16 CDB6N4D20 CDB6N4D25 CDB6N4D32 CDB6N4D40 CDB6N4D50 CDB6N4D63
2P
3P
4P
2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8
CDB6N1B1 CDB6N1B3 CDB6N1B6 CDB6N1B10 CDB6N1B16 CDB6N1B20 CDB6N1B25 CDB6N1B32 CDB6N1B40 CDB6N1B50 CDB6N1B63 CDB6N2B1 CDB6N2B3 CDB6N2B6 CDB6N2B10 CDB6N2B16 CDB6N2B20 CDB6N2B25 CDB6N2B32 CDB6N2B40 CDB6N2B50 CDB6N2B63 CDB6N3B1 CDB6N3B3 CDB6N3B6 CDB6N3B10 CDB6N3B16 CDB6N3B20 CDB6N3B25 CDB6N3B32 CDB6N3B40 CDB6N3B50 CDB6N3B63 CDB6N4B1 CDB6N4B3 CDB6N4B6 CDB6N4B10 CDB6N4B16 CDB6N4B20 CDB6N4B25 CDB6N4B32 CDB6N4B40 CDB6N4B50 CDB6N4B63
Tripping Curve
B
6
C
D
Delixi Electric
CDB6&CDB6LE Electrical Auxiliaries
Type
Voltage
Reference
OF
AC230
CDB6OF230AC
AC400
CDB6OF400AC
DC24
CDB6OF24DC
DC48
CDB6OF48DC
DC110
CDB6OF110DC
DC220
CDB6OF220DC
AC230
CDB6SD230AC
AC400
CDB6SD400AC
DC24
CDB6SD24DC
DC48
CDB6SD48DC
DC110
CDB6SD110DC
DC220
CDB6SD220DC
AC230
CDB6MX230AC
DC24
CDB6MX24AC
SD
MX+OF*
OF contact auxiliary
SD fault-indicating switch
MX+OF shunt trip release
Delixi Electric
7
CDB17 Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 6000A
Function
CDB17N miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation
Description
Technical data Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A Rated voltage: 230/400V AC Breaking capacity Rate current
Breaking capacity Icn (A)
Type
Poles
Voltage (V)
1-63A
6000
B
1P 2P,3P,4P 1P 2P,3P,4P 1P 2P,3P,4P
230 400 230 400 230 400
C D
Tropicalization: treatment 2 Protection degree: 2 Connection: up to 25mm 2 cables Tripping curves: B curve: the magnetic release operates between 3 and 5 In C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In 35 mm standard DIN rail mounting
Standard and certification IEC 60898-1 KEMA, CB, CE
Overall dimensions Unit:mm
8
Delixi Electric
CDB17 Standard: IEC 60898-1 Trip Curve: B, C and D curves Breaking Capacity: 6000A Type
Rating (A)
Width Reference (in mod.of 9mm) B curve
1P
1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63 1 3 6 10 16 20 25 32 40 50 63
2 2 2 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8
2P
3P
4P
C curve CDB17N1C1 CDB17N1C3 CDB17N1C6 CDB17N1C10 CDB17N1C16 CDB17N1C20 CDB17N1C25 CDB17N1C32 CDB17N1C40 CDB17N1C50 CDB17N1C63 CDB17N2C1 CDB17N2C3 CDB17N2C6 CDB17N2C10 CDB17N2C16 CDB17N2C20 CDB17N2C25 CDB17N2C32 CDB17N2C40 CDB17N2C50 CDB17N2C63 CDB17N3C1 CDB17N3C3 CDB17N3C6 CDB17N3C10 CDB17N3C16 CDB17N3C20 CDB17N3C25 CDB17N3C32 CDB17N3C40 CDB17N3C50 CDB17N3C63 CDB17N4C1 CDB17N4C3 CDB17N4C6 CDB17N4C10 CDB17N4C16 CDB17N4C20 CDB17N4C25 CDB17N4C32 CDB17N4C40 CDB17N4C50 CDB17N4C63
CDB17N1B1 CDB17N1B3 CDB17N1B6 CDB17N1B10 CDB17N1B16 CDB17N1B20 CDB17N1B25 CDB17N1B32 CDB17N1B40 CDB17N1B50 CDB17N1B63 CDB17N2B1 CDB17N2B3 CDB17N2B6 CDB17N2B10 CDB17N2B16 CDB17N2B20 CDB17N2B25 CDB17N2B32 CDB17N2B40 CDB17N2B50 CDB17N2B63 CDB17N3B1 CDB17N3B3 CDB17N3B6 CDB17N3B10 CDB17N3B16 CDB17N3B20 CDB17N3B25 CDB17N3B32 CDB17N3B40 CDB17N3B50 CDB17N3B63 CDB17N4B1 CDB17N4B3 CDB17N4B6 CDB17N4B10 CDB17N4B16 CDB17N4B20 CDB17N4B25 CDB17N4B32 CDB17N4B40 CDB17N4B50 CDB17N4B63
D curve CDB17N1D1 CDB17N1D3 CDB17N1D6 CDB17N1D10 CDB17N1D16 CDB17N1D20 CDB17N1D25 CDB17N1D32 CDB17N1D40 CDB17N1D50 CDB17N1D63 CDB17N2D1 CDB17N2D3 CDB17N2D6 CDB17N2D10 CDB17N2D16 CDB17N2D20 CDB17N2D25 CDB17N2D32 CDB17N2D40 CDB17N2D50 CDB17N2D63 CDB17N3D1 CDB17N3D3 CDB17N3D6 CDB17N3D10 CDB17N3D16 CDB17N3D20 CDB17N3D25 CDB17N3D32 CDB17N3D40 CDB17N3D50 CDB17N3D63 CDB17N4D1 CDB17N4D3 CDB17N4D6 CDB17N4D10 CDB17N4D16 CDB17N4D20 CDB17N4D25 CDB17N4D32 CDB17N4D40 CDB17N4D50 CDB17N4D63
Tripping Curve
B
Delixi Electric
C
D
9
CDB3 Standard: IEC 60898-1 Trip Curve: C and D curves Breaking Capacity: 3000A
Function
CDB3 phase-neutral circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation
Description
Technical data Rated current: 6, 10, 16, 20, 25, 32A Rated voltage: 230V AC Breaking capacity: 3 kA Tripping curves: C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In Tropicalization: treatment 2 Protection degree: 2 Connection Up to 16mm2 cables 35mm standard DIN rail mounting
Standard and certification IEC 60898-1 Type
Rating (A)
Width (in mod.of 9mm)
Reference C curve
D curve
1P+N
6 10 16 20 25 32
2 2 2 2 2 2
CDB3a5C6 CDB3a5C10 CDB3a5C16 CDB3a5C20 CDB3a5C25 CDB3a5C32
CDB3a5D6 CDB3a5D10 CDB3a5D16 CDB3a5D20 CDB3a5D25 CDB3a5D32
Overall dimensions
Tripping Curve
C
10
D
Delixi Electric
CDB2 Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A
Function
CDB2 miniature circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Control Isolation
Description
Technical data Rated current: 63, 80, 100, 125 A Rated voltage : 230/400V AC Breaking capacity Rating (A)
Type
Voltage (V)
Breaking capacity (kA)
63 ~125
1P 2/3/4P
230 400
10 10
Tripping curves: C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In Mechanical durability: 8,500 (In 100A) / 7,000 (In=125A) Electrical durability: 1,500 (In 100A) / 1,000 (In=125A) Tropicalization: treatment 2 Protection degree: 2 Connection Up to 50 mm 2 cables 35mm standard DIN rail mounting Closed position indication
Standard and certification IEC 60947-2 SEMKO, CE
Overall dimensions Unit:mm
Delixi Electric
11
CDB2 Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A Type
Rating (A)
Width (in mod.of 9mm)
Reference C curve
D curve
1P
63 80 100 125
3 3 3 3
CDB2H1C63 CDB2H1C80 CDB2H1C100 CDB2H1C125
CDB2H1D63 CDB2H1D80 CDB2H1D100 CDB2H1D125
2P
63 80 100 125
6 6 6 6
CDB2H2C63 CDB2H2C80 CDB2H2C100 CDB2H2C125
CDB2H2D63 CDB2H2D80 CDB2H2D100 CDB2H2D125
3P
63 80 100 125
9 9 9 9
CDB2H3C63 CDB2H3C80 CDB2H3C100 CDB2H3C125
CDB2H3D63 CDB2H3D80 CDB2H3D100 CDB2H3D125
4P
63 80 100 125
12 12 12 12
CDB2H4C63 CDB2H4C80 CDB2H4C100 CDB2H4C125
CDB2H4D63 CDB2H4D80 CDB2H4D100 CDB2H4D125
Tripping Curve
C
12
D
Delixi Electric
CDB5 Standard: IEC 60947-3
Function
CDB5 switch disconnectors combine the following functions: Making and breaking normal load circuits Isolation
Description
Technical data Rated current: 20, 32, 63, 100 A Rated voltage: 230/400V AC Mechanical durability: 8500 Electrical durability: 1500 Short-time withstand capacity for 1 s: 12Ie Tropicalization: treatment 2 Protection degree: 2 Connection Up to 35 mm2 cables 35 mm standard DIN rail mounting Isolation with positive break indication
Standard and certification IEC 60947-3
Overall dimensions Unit:mm
Delixi Electric
13
CDB5 Standard: IEC 60947-3
14
Type
Rating (A)
Voltage (V AC)
Width (in mod.of 9mm)
Reference
1P
20 32 63 100
230 230 230 230
2 2 2 2
CDB5120 CDB5132 CDB5163 CDB51100
2P
20 32 63 100
400 400 400 400
4 4 4 4
CDB5220 CDB5232 CDB5263 CDB52100
3P
20 32 63 100
400 400 400 400
6 6 6 6
CDB5320 CDB5332 CDB5363 CDB53100
4P
20 32 63 100
400 400 400 400
8 8 8 8
CDB5420 CDB5432 CDB5463 CDB54100
Delixi Electric
CDB6LE Standard: IEC 61009 Trip Curve: C and D curves Breaking Capacity: 3000A Sensitivity: 30mA
Function
CDB6LE electronic type residual current operated circuit breakers combine the following functions: Overload protection Protection against short-circuit current Protection for users against indirect contact Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc) Isolation
Description
Technical data Rated current: 6, 10, 16, 20, 25, 32, 40, 50, 60A Rated voltage: 230V AC for 1P+N/2P, 400V AC for 3P/3P+N/4P Sensitivity: 30 mA Tropicalization: treatment 2 Protection degree: 2 Connection Up to 16 mm2 cables Tripping curves: C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In Mechanical indication of the earth fault on the front face by a black mechanical indicator 35 mm standard DIN rail mounting.
Standard and certification IEC 61009
Overall dimensions
CDB6LE-32
CDB6LE-63
Delixi Electric
15
CDB6LE Standard: IEC 61009 Trip Curve: C and D curves Breaking Capacity: 3000A Sensitivity: 30mA Type
Voltage (V)
Sensitivity Rating (mA) (A)
1P+N
230
30
2P
230
30
3P
400
30
3P+N
400
30
4P
400
30
6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60 6 10 16 20 25 32 40 50 60
Width Reference (in mod.of 9mm) C curve 5 5 5 5 5 5 6 6 6 7 7 7 7 7 7 8 8 8 10 10 10 10 10 10 12 12 12 11 11 11 11 11 11 14 14 14 13 13 13 13 13 13 16 16 16
CDB6LEa1C6S CDB6LLEa1C10S CDB6LEa1C16S CDB6LEa1C20S CDB6LEa1C25S CDB6LEa1C32S CDB6LEa1C40S CDB6LEa1C50S CDB6LEa1C60S CDB6LEa2C6S CDB6LEa2C10S CDB6LEa2C16S CDB6LEa2C20S CDB6LEa2C25S CDB6LEa2C32S CDB6LEa2C40S CDB6LEa2C50S CDB6LEa2C60S CDB6LEa3C6S CDB6LEa3C10S CDB6LEa3C16S CDB6LEa3C20S CDB6LEa3C25S CDB6LEa3C32S CDB6LEa3C40S CDB6LEa3C50S CDB6LEa3C60S CDB6LEa4C6S CDB6LEa4C10S CDB6LEa4C16S CDB6LEa4C20S CDB6LEa4C25S CDB6LEa4C32S CDB6LEa4C40S CDB6LEa4C50S CDB6LEa4C60S CDB6LEa6C6S CDB6LEa6C10S CDB6LEa6C16S CDB6LEa6C20S CDB6LEa6C25S CDB6LEa6C32S CDB6LEa6C40S CDB6LEa6C50S CDB6LEa6C60S
D curve CDB6LEa1D6S CDB6LEa1D10S CDB6LEa1D16S CDB6LEa1D20S CDB6LEa1D25S CDB6LEa1D32S CDB6LEa1D40S CDB6LEa1D50S CDB6LEa1D60S CDB6LEa2D6S CDB6LEa2D10S CDB6LEa2D16S CDB6LEa2D20S CDB6LEa2D25S CDB6LEa2D32S CDB6LEa2D40S CDB6LEa2D50S CDB6LEa2D60S CDB6LEa3D6S CDB6LEa3D10S CDB6LEa3D16S CDB6LEa3D20S CDB6LEa3D25S CDB6LEa3D32S CDB6LEa3D40S CDB6LEa3D50S CDB6LEa3D60S CDB6LEa4D6S CDB6LEa4D10S CDB6LEa4D16S CDB6LEa4D20S CDB6LEa4D25S CDB6LEa4D32S CDB6LEa4D40S CDB6LEa4D50S CDB6LEa4D60S CDB6LEa6D6S CDB6LEa6D10S CDB6LEa6D16S CDB6LEa6D20S CDB6LEa6D25S CDB6LEa6D32S CDB6LEa6D40S CDB6LEa6D50S CDB6LEa6D60S
Tripping Curve
B
16
C
D
Delixi Electric
CDB3LE Standard: IEC 61009 Trip Curve: C curves Breaking Capacity: 3000A Sensitivity: 30mA
Function
CDB3LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Additional protection for users against direct contacts (30mA) Protection of electrical installations against insulation faults (fire hazard, etc) Isolation
Description
Technical data Rated current: 6, 10, 16, 20, 25, 32, 40A Rated voltage: 230V AC Breaking capacity: 3kA Sensitivity: 30mA Tripping curve: C curve: the magnetic release operates between 5 and 10 In Tropicalization: treatment 2 Protection degree: 2 Connection Up to 6 mm2 cables Mechanical indication of the earth fault on the front face by a red mechanical indicator 35 mm standard DIN rail mounting
Standard and certification IEC 61009 Type
Sensltivity(mA) Width (in mod.of 9mm) 4
1P+N 30
Rating(A)
Reference C curve
6 10 16 20 25 32 40
CDB3LEa5C6S CDB3LEa5C10S CDB3LEa5C16S CDB3LEa5C20S CDB3LEa5C25S CDB3LEa5C32S CDB3LEa5C40S
Overall dimensions Unit:mm
Tripping Curve
C
Delixi Electric
17
CDB2LE Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A Sensitivity: 100mA, 300mA
Function
CDB2LE electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Protection of electrical installations against insulation faults (fire hazard, etc) Isolation
Description
Technical data Rated current: 63A, 80A,100A Rated voltage: 230V for 1P+N; 400V for 2P/3P/3P+N/4P Sensitivity: 100mA,300mA Rated ultimate short-circuit breaking capacity (Icu): 10,000A Rated service short-circuit breaking capacity (Ics): 7,500A Tripping curves: C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In 2 types of residual current tripping are available: Instantaneous Time-delay with a maximum delay time of 0.2 s Tropicalization: treatment 2 Protection degree: 2 Connection Up to 50 mm2 cables Mechanical indication of the earth fault on the front face by a black mechanical indicator Closed position indication 35 mm standard DIN rail mounting
Standard and certification IEC 60947-2
Overall dimensions Unit:mm
18
Delixi Electric
CDB2LE Standard: IEC 60947-2 Trip Curve: C and D curves Breaking Capacity: 10000A Sensitivity: 100mA, 300mA Type
Width Sensitivity Rating (in mod.of 9mm) (mA) (A)
Reference C curve
D curve
1P+N 6
100 100 100 300 300 300
63 80 100 63 80 100
CDB2LEH1C63Y CDB2LEH1C80Y CDB2LEH1C100Y CDB2LEH1C63T CDB2LEH1C80T CDB2LEH1C100T
CDB2LEH1D63Y CDB2LEH1D80Y CDB2LEH1D100Y CDB2LEH1D63T CDB2LEH1D80T CDB2LEH1D100T
2P
9
100 100 100 300 300 300
63 80 100 63 80 100
CDB2LEH2C63Y CDB2LEH2C80Y CDB2LEH2C100Y CDB2LEH2C63T CDB2LEH2C80T CDB2LEH2C100T
CDB2LEH2D63Y CDB2LEH2D80Y CDB2LEH2D100Y CDB2LEH2D63T CDB2LEH2D80T CDB2LEH2D100T
3P
12
100 100 100 300 300 300
63 80 100 63 80 100
CDB2LEH3C63Y CDB2LEH3C80Y CDB2LEH3C100Y CDB2LEH3C63T CDB2LEH3C80T CDB2LEH3C100T
CDB2LEH3D63Y CDB2LEH3D80Y CDB2LEH3D100Y CDB2LEH3D63T CDB2LEH3D80T CDB2LEH3D100T
3P+N 12
100 100 100 300 300 300
63 80 100 63 80 100
CDB2LEH6C63Y CDB2LEH6C80Y CDB2LEH6C100Y CDB2LEH6C63T CDB2LEH6C80T CDB2LEH6C100T
CDB2LEH6D63Y CDB2LEH6D80Y CDB2LEH6D100Y CDB2LEH6D63T CDB2LEH6D80T CDB2LEH6D100T
4P
100 100 100 300 300 300
63 80 100 63 80 100
CDB2LEH4C63Y CDB2LEH4C80Y CDB2LEH4C100Y CDB2LEH4C63T CDB2LEH4C80T CDB2LEH4C100T
CDB2LEH4D63Y CDB2LEH4D80Y CDB2LEH4D100Y CDB2LEH4D63T CDB2LEH4D80T CDB2LEH4D100T
15
Tripping Curve
C
Delixi Electric
D
19
CDB7LSP Standard: IEC 61009 Trip Curve: C and D curves Breaking Capacity: 6000A Sensitivity:30mA
Function
CDB7LSP electronic type residual current operated circuit breakers combine the following functions: Protection of circuits against overload currents Protection of circuits against short-circuit currents Protection of users against indirect contact Additional protection for users against direct contacts (30mA) Protection of electrical installations against insulation faults (fire hazard, etc)
Description
Technical data Rated current: 6, 10, 16, 20, 25, 32, 40A Rated voltage: 230V AC Breaking capacity: 6kA Sensitivity: 30mA Tripping curve: B curve: the magnetic release operates between 3 and 5 In C curve: the magnetic release operates between 5 and 10 In D curve: the magnetic release operates between 10 and 14 In Tropicalization: treatment 2 Protection degree: 2 Connection Up to 10 mm2 cables Mechanical indication of the earth fault on the front face by a red mechanical indicator 35 mm standard DIN rail mounting
Standard and certification IEC 61009
Type Voltage Sensitivity Rating Width Reference (V) (mA) (A) (mm) B curve 1P+N 230
30
6 10 16 20 25 32 40
18 18 18 18 18 18 18
CDB7LSPN1B6S CDB7LSPN1B10S CDB7LSPN1B16S CDB7LSPN1B20S CDB7LSPN1B25S CDB7LSPN1B32S CDB7LSPN1B40S
C curve
D curve
CDB7LSPN1C6S CDB7LSPN1C10S CDB7LSPN1C16S CDB7LSPN1C20S CDB7LSPN1C25S CDB7LSPN1C32S CDB7LSPN1C40S
CDB7LSPN1D6S CDB7LSPN1D10S CDB7LSPN1D16S CDB7LSPN1D20S CDB7LSPN1D25S CDB7LSPN1D32S CDB7LSPN1D40S
Overall dimensions
20
Delixi Electric
CDL7 Standard:IEC 61008 Sensitivity: 10mA, 30mA, 100mA, 300mA RCCB: Type A , Type AC
Function
CDL7 electromagnetic type residual current switch combine the following functions: Protection for users against indirect contact Additional protection for users against direct contacts (30mA) Protection for electrical installations against insulation faults (fire hazard, etc) Isolation
Description
Technical data Rated current: 25, 40, 63, 80, 100A Rated voltage: 230/400V AC Sensitivity: 10mA, 30mA, 100mA, 300mA Mechanical durability: 2000 Electrical durability: 1000 Tropicalization: treatment 2 Protection degree: 2 Connection Tunnel terminals Up to 16 mm2 cables Type A or type AC RCCB, without overload or short-circuit protection Don’t need any auxiliary supply source. Instantaneous earth fault trip, unadjustable Mechanical indication of the earth fault on the front face by a red mechanical indicator 35 mm standard DIN rail mounting
Standard and certification IEC 61008 KEMA, CB
Overall dimensions Unit:mm
Delixi Electric
21
CDL7 Standard:IEC 61008 Sensitivity: 10mA, 30mA, 100mA, 300mA RCCB: Type A , Type AC
22
Type
Width (in mod.of 9mm)
Rating Sensitivity (A) (mA)
Reference A type
AC type
2P
4
25 25 40 63 80 100 25 40 63 80 100 25 40 63 80 100 63 80 100 63 80 100
10 30 30 30 30 30 100 100 100 100 100 300 300 300 300 300 100 100 100 300 300 300
CDL7225LA CDL7225SA CDL7240SA CDL7263SA CDL7280SA CDL72100SA CDL7225YA CDL7240YA CDL7263YA CDL7280YA CDL72100YA CDL7225TA CDL7240TA CDL7263TA CDL7280TA CDL72100TA CDL7263YAS CDL7280YAS CDL72100YAS CDL7263TAS CDL7280TAS CDL72100TAS
CDL7225LC CDL7225SC CDL7240SC CDL7263SC CDL7280SC CDL72100SC CDL7225YC CDL7240YC CDL7263YC CDL7280YC CDL72100YC CDL7225TC CDL7240TC CDL7263TC CDL7280TC CDL72100TC CDL7263YCS CDL7280YCS CDL72100YCS CDL7263TCS CDL7280TCS CDL72100TCS
4P
8
25 25 40 63 80 100 25 40 63 80 100 25 40 63 80 100 63 80 100 63 80 100
10 30 30 30 30 30 100 100 100 100 100 300 300 300 300 300 100 100 100 300 300 300
CDL7425LA CDL7425SA CDL7440SA CDL7463SA CDL7480SA CDL74100SA CDL7425YA CDL7440YA CDL7463YA CDL7480YA CDL74100YA CDL7425TA CDL7440TA CDL7463TA CDL7480TA CDL74100TA CDL7463YAS CDL7480YAS CDL74100YAS CDL7463TAS CDL7480TAS CDL74100TAS
CDL7425LC CDL7425SC CDL7440SC CDL7463SC CDL7480SC CDL74100SC CDL7425YC CDL7440YC CDL7463YC CDL7480YC CDL74100YC CDL7425TC CDL7440TC CDL7463TC CDL7480TC CDL74100TC CDL7463YCS CDL7480YCS CDL74100YCS CDL7463TCS CDL7480TCS CDL74100TCS
Delixi Electric
CDY1 Surge Protective Devices Standard: IEC61643-1
Function
CDY1 surge protective devices provide: Applicable to household appliances and the like to offer protection When there is an over-voltage caused by either lightning strike or operation in the circuit
Description
Technical data Type Pole Nominal discharge current In(8/20us) kA Maximum discharge current Imax(8/20us) kA Maximum continuous operational voltage Uc V Protection level Up kV Leakage cur rent (75%Uc 1mA) uA Response time ns
CDY1-10 CDY1-20 CDY1-40 CDY1-60
CDY1-80
CDY1-100 CDY1-120
1P+N, 2P 5
1P, 1P+N, 2P, 3P, 3P+N, 4P 10 20 30 40
50
60
10
20
100
120
275 1.3
40
60
80
320
275 385 420 275 385 420 275 385 420 275 385 420 275 385 420 275 385 420
1.3
1.3 1.5 1.8 1.5 1.8 2 2 2.2 2.5 2 2.2 2.2 2.2 2.5 2.5 2.2 2.5 2.5
20 25
Standard and certification IEC61643-1
Overall dimensions
CDY1-10
CDY1-20 40 60
CDY1-80 100 120
Delixi Electric
23
CDY1 Surge Protective Devices Standard: IEC61643-1
Imax
Pole
Refernce
10KA
1P+N
CDY1105
10KA
2P
CDY1102
20KA
1P
CDY1201
20KA
2P
CDY1202
20KA
3P
CDY1203
20KA
4P
CDY1204
20KA
1P+N
CDY1205
20KA
3P+N
CDY1206
40KA
1P
CDY1401
40KA
2P
CDY1402
40KA
3P
CDY1403
40KA
4P
CDY1404
40KA
1P+N
CDY1405
40KA
3P+N
CDY1406
60KA
1P
CDY1601
60KA
2P
CDY1602
60KA
3P
CDY1603
60KA
4P
CDY1604
60KA
1P+N
CDY1605
60KA
3P+N
CDY1606
80KA
1P
CDY1801
80KA
2P
CDY1802
80KA
3P
CDY1803
80KA
4P
CDY1804
80KA
1P+N
CDY1805
80KA
3P+N
CDY1806
100KA
1P
CDY11001
100KA
2P
CDY11002
100KA
3P
CDY11003
100KA
4P
CDY11004
100KA
1P+N
CDY11005
100KA
3P+N
CDY11006
120KA
1P
CDY11201
120KA
2P
CDY11202
120KA
3P
CDY11203
120KA
4P
CDY11204
120KA
1P+N
CDY11205
120KA
3P+N
CDY11206
20KA
Phase modle
CDY120PM
40KA
Phase modle
CDY140PM
60KA
Phase modle
CDY160PM
60KA
N-PE
CDY160NP
80KA
N-PE
CDY180NP
100KA
N-PE
CDY1100NP
120KA
N-PE
CDY1120NP
Note:"
Uc
24
" express Maximum continuous operational voltage (Uc) code
275V 275
320V 320
385V 385
420V 420
Delixi Electric
CDPZ50 Standard: IEC60439-1 IEC60670
Function
CDPZ50 distribution box provides illumination devices, sockets and electrical appliances with functions as follows: Protection against overload Protection against over voltage Protection against leakage
Description
Technical data Rated operational voltage Maximum rated current Rated insulation voltage Rated frequency Degree of protection Instantaneous withstand current
AC 400V or AC 230V 100A 500V 50Hz IP30 6KA
Construction feature Holistic steel-plastic construction Free assembly of components Beautiful design Flame retardant industrial plastic in panel The whole panel can move vertically
Standard and certification IEC60439-1 IEC60670
Type
The amount of unit loop*
Reference
Surface installation
6
CDPZ50M6
8
CDPZ50M8
12
CDPZ50M12
16
CDPZ50M16
20
CDPZ50M20
24
CDPZ50M24
6
CDPZ50R6
8
CDPZ50R8
12
CDPZ50R12
16
CDPZ50R16
20
CDPZ50R20
24
CDPZ50R24
Flush installation
*:18mm for one unit loop
Delixi Electric
25
CDPZ50 Standard: IEC60439-1 IEC60670
Overall dimension Unit:mm
Surface installation Loop number
Flush installation
Surface installation
Flush installation
Thickness
A
B
A
B
C
6
171
220
163
220
90
8
207
220
199
220
90
12
279
220
279
220
90
16
351
220
343
220
90
20
423
220
413
220
90
24*
364
303
383
282
90
*:two rows product
26
Delixi Electric
DDS607 Single-phase Electronic Watt-hour Meter Standard:IEC 620531-21:2003
Function
DDS607 single-phase electronic watt-hour meter provide: Measuring energy in household and commercial single-phase network services
Description
Technical Data Accuracy class: 1.0, 2.0 Reference voltage:220V Current specification:1.5(6)A,3(6)A,2.5(10)A,5(20)A,5(30)A 10(40)A,15(60)A,20(80)A,30(100)A Power: 2W/10VA (voltage circuit), 4VA(Current circuit) Two-way measurement function: Being able to accurately measure, antitwodirections of power and the total electricityconsumption in one direction Extended functions: Optional liquid crystal display, infrared communications and 485 communications Normal work temperature:-10-~+45 Limit working temperature:-25-~+55 Normal work voltage:0.9~1.1 Reference voltage Limit work voltage:0.7~1.2 Reference voltage Relative Humidity: 85% Installation conditions:Meter should be installed in indoor drying, ventilation, fire-resistant, solid walls height of 1.8 m about the use of non-corrosive gases in the nvironment, should be moisture-proof. Lightning request:Thunderstorms in more places should be installed in the installation of lightning equipment
Standard and Certification IEC620531-21:2003 KEMA
Overall dimensions
Single-phase Type A,C Meter
Delixi Electric
Single-phase LCD Meter
27
DDS607 Single-phase Electronic Watt-hour Meter Standard:IEC 620531-21:2003
Ordering informationn Function Description
Current specification
Reference
Type A (Import chip)
1.5(6)A
DDS607N16M4A
Type A (Import chip)
2.5(10)A
DDS607N110M4A
Type A (Import chip)
5(20)A
DDS607N120M4A
Type A (Import chip)
5(30)A
DDS607N130M6A
Type A (Import chip)
10(40)A
DDS607N140M4A
Type A (Import chip)
15(60)A
DDS607N160M4A
Type A (Import chip)
20(80)A
DDS607N180M4A
Type A (Import chip)
30(100)A
DDS607N1100M3A
Type C (Domestic chip)
1.5(6)A
DDS607N26M4A
Type C (Domestic chip)
2.5(10)A
DDS607N210M4C
Type C (Domestic chip)
5(20)A
DDS607N220M4C
Type C (Domestic chip)
5(30)A
DDS607N230M6C
Type C (Domestic chip)
10(40)A
DDS607N240M4C
Type C (Domestic chip)
15(60)A
DDS607N260M4C
Type C (Domestic chip)
20(80)A
DDS607N280M4C
Type C (Domestic chip)
30(100)A
DDS607N2100M3C
LCD without 485 communications
1.5(6)A
DDS607N16M4CD
LCD without 485 communications
2.5(10)A
DDS607N110M4CD
LCD without 485 communications
5(20)A
DDS607N120M4CD
LCD without 485 communications
5(30)A
DDS607N130M6CD
LCD without 485 communications
10(40)A
DDS607N140M4CD
LCD without 485 communications
15(60)A
DDS607N160M4CD
LCD without 485 communications
20(80)A
DDS607N180M4CD
LCD with 485 communications
1.5(6)A
DDS607N16M4CD485
LCD with 485 communications
5(20)A
DDS607N120M4CD485
LCD with 485 communications
10(40)A
DDS607N140M4CD485
LCD with 485 communications
15(60)A
DDS607N160M4CD485
LCD with 485 communications and infrared communications 1.5(6)A
DDS607N116M4CD485I
LCD with 485 communications and infrared communications 2.5(10)A
DDS607N110M4CD485I
LCD with 485 communications and infrared communications 5(20)A
DDS607N120M4CD485I
LCD with 485 communications and infrared communications 5(30)A
DDS607N130M6CD485I
LCD with 485 communications and infrared communications 10(40)A
DDS607N140M4CD485I
LCD with 485 communications and infrared communications 15(60)A
DDS607N160M4CD485I
LCD with 485 communications and infrared communications 20(80)A
DDS607N180M4CD485I
LCD with 485 communications and infrared communications 30(100)A
DDS607N1100M3CD485I
Note: Users need special specifications can be customized
28
Delixi Electric
CDM1 Standard: IEC 60947-2
Function
CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit faults To protect motors against overload, undervoltage and short-circuit faults (Inm²400A) To infrequently start and control AC motors
Description
Technical data Main technical parameters are shown in the table below Type Frame size rated current A Number of poles Rated frequency Hz Rated current In A
CDM1-63 CDM1-100 CDM1-225 CDM1-400 CDM1-630 CDM1-800 CDM1-1250 63 100 225 400 630 800 1250
Rated insulation voltage Ui V Rated impulse withstand voltage Uimp V Rated operational voltage Ue V Icu kA Type M (400V) Type L Ics kA Type M (400V) Type L Arcing distance mm Durability Cycles/h Electrical Mechanical Power consu- Fixed mpution W Plug-in
690V
3P,4P 50 10 16 20 25 32 40 50 63
2P,3P,4P
3P,4P
3P
16 20 100 125 200 350 400 500 400 500 700 800 25 30 160 180 250 315 630 630 700 1000 32 40 200 225 400 800 1250 50 63 80 100 800V
6000V 8000V
400V
400V / 690V
400V
50 25 30 18 50 120 4000 6000 25 30
50 35 30 26
50 35 30 26
120 3000 7000 40 50
120 1500 6500 60 75
70 50 40 30 100 60 1000 4000 40 110
400V 690V 65 45 42 34
400V 70 50 40 30
85 45 -
60 1000 4000 150 200
20 500 2500 135 190
20 500 2500 240 300
Constructional features Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent The circuit breaker can be of fixed type or plug-in type For 4-pole circuit breakers: N-pole without overcurrent release, it switches on and off with other poles ( Npole lead-make, lag-break) Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the accessories part
Standard and certification IEC 60947-2 KEMA, SEMKO, CB, CE
Delixi Electric
29
CDM1 Standard: IEC 60947-2
Type CDM1-63
In A 3P
4P
CDM1-100
2P
3P
4P
CDM1-225
30
2P
10 16 20 25 32 40 50 63 10 16 20 25 32 40 50 63 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 16 20 25 32 40 50 63 80 100 100 125 160 180 200 225
Reference Type M CDM163M103 CDM163M163 CDM163M203 CDM163M253 CDM163M323 CDM163M403 CDM163M503 CDM163M633 CDM163M104 CDM163M164 CDM163M204 CDM163M254 CDM163M324 CDM163M404 CDM163M504 CDM163M634 CDM1100M162 CDM1100M202 CDM1100M252 CDM1100M322 CDM1100M402 CDM1100M502 CDM1100M632 CDM1100M802 CDM1100M1002 CDM1100M163 CDM1100M203 CDM1100M253 CDM1100M323 CDM1100M403 CDM1100M503 CDM1100M633 CDM1100M803 CDM1100M1003 CDM1100M164 CDM1100M204 CDM1100M254 CDM1100M324 CDM1100M404 CDM1100M504 CDM1100M634 CDM1100M804 CDM1100M1004 CDM1225M1002 CDM1225M1252 CDM1225M1602 CDM1225M1802 CDM1225M2002 CDM1225M2252
Type L CDM163L103 CDM163L163 CDM163L203 CDM163L253 CDM163L323 CDM163L403 CDM163L503 CDM163L633 -----------------CDM1100L163 CDM1100L203 CDM1100L253 CDM1100L323 CDM1100L403 CDM1100L503 CDM1100L633 CDM1100L803 CDM1100L1003 ----------------
Delixi Electric
CDM1 Standard: IEC 60947-2
Type 3P
4P
CDM1-400
3P
4P
CDM1-630
3P
4P
CDM1-800
3P
4P
CDM1-1250 3P
In A
Reference
100 125 160 180 200 225 100 125 160 180 200 225 200 225 250 315 350 400 200 215 250 315 350 400 400 500 630 400 500 630 400 500 630 700 800 400 500 630 700 800 700 800 1000 1250
Type M CDM1225M1003 CDM1225M1253 CDM1225M1603 CDM1225M1803 CDM1225M2003 CDM1225M2253 CDM1225M1004 CDM1225M1254 CDM1225M1604 CDM1225M1804 CDM1225M2004 CDM1225M2254 CDM1400M2003 CDM1400M2253 CDM1400M2503 CDM1400M3153 CDM1400M3503 CDM1400M4003 CDM1400M2004 CDM1400M2254 CDM1400M2504 CDM1400M3154 CDM1400M3504 CDM1400M4004 CDM1630M4003 CDM1630M5003 CDM1630M6303 CDM1630M4004 CDM1630M5004 CDM1630M6304 CDM1800M4003 CDM1800M5003 CDM1800M6303 CDM1800M7003 CDM1800M8003 CDM1800M4004 CDM1800M5004 CDM1800M6304 CDM1800M7004 CDM1800M8004 CDM11250M7003 CDM11250M8003 CDM11250M10003 CDM11250M12503
Type L CDM1225L1003 CDM1225L1253 CDM1225L1603 CDM1225L1803 CDM1225L2003 CDM1225L2253 ------CDM1400L2003 CDM1400L2253 CDM1400L2503 CDM1400L3153 CDM1400L3503 CDM1400L4003 ------CDM1630L4003 CDM1630L5003 CDM1630L6303 ---CDM1800L4003 CDM1800L5003 CDM1800L6303 CDM1800L7003 CDM1800L8003 ----------
Note: The connection mode for CDM1 is the fixed type front connection.
Delixi Electric
31
CDM1 Standard: IEC 60947-2
Key to overall dimensions Type
Poles Overall dimensions L
Install dimensions
L1
W
H
H1
H2
a
b
CDM1-63L
3
135 21
76
89.5
74
21
25
117
3.5
CDM1-63M
3
135 21
76
99
82
28
25
117
3.5
CDM1-63M
4
135 21
103 99
82
28
25
117
3.5
CDM1-100M
2
150 51
65
103.5
87
24
--
129
4.5
CDM1-100L
3
150 51
92
87
68
25
30
129
4.5
CDM1-100M
3
150 51
92
103.5
87
24
30
129
4.5
CDM1-100M
4
150 51
122 103.5
87
24
30
129
4.5
CDM1-225M
2
165 64
75
104
24.5
--
126
5.5
CDM1-225L
3
165 64
107 108
87
24.5
35
126
5.5
CDM1-225M
3
165 64
107 124.5
104
24
35
126
5.5
CDM1-225M
4
165 64
142 124.5
124.5
d
104
24.5
35
126
5.5
CDM1-400L,M 3
257 105 140 146
100
36.5
44
215
6.5
4
257 105 184 146
100
36.5
44
215
6.5
CDM1-630L,M 3
270 118
182 160
108
41
58
200
7
4
270 118
CDM1-400M CDM1-630M
240 160
108
41
58
200
7
CDM1-800L,M 3
280 102 210 146
103
34.5
70
243
7
CDM1-800M
4
280 102 280 146
103
34.5
70
243
7
CDM1-1250M
3
406 104 210 190
140.5
58.5
70
375
10
Overall dimensions Unit:mm
2P
32
3P
4P
Delixi Electric
CDM1 Standard: IEC 60947-2
Unit:mm
A 117 129 126 215 200 243
B 25 30 35 44 58 70
H 49 54 54 76 83 76
Unit:mm
A 35 35 65 60 48
Delixi Electric
B 11.5 31 15 15 15
H 46 48 61 61 66
33
CDM1 Standard: IEC 60947-2
Accessories The accessories are fixed into the circuit breaker.
MN (Undervoltage Release) Technical data Rated operating voltage Us(V) Drop-out voltage(V) Pick-up voltage(V)
230V, 400V AC (0.35~0.7) Us (0.85~1.1) Us
MX (Shunt Release) Technical data Rated control voltage US(V) Operating voltage(V)
230V, 400V AC (0.7~1.1) US
OF (Auxiliary Contact) Technical data Rated thermal current Ith 3A Rated operating voltage US(V) 1NO+1NC (Change over) 2NO+2NC (Change over)
0.4A (400V AC)
SD (Alarm Switch) Technical data Rated thermal current Ith 3A Rated operating voltage US(V)
0.26A (400V AC) 0.4A (400V AC)
1NO+1NC
34
Delixi Electric
CDM1 Standard: IEC 60947-2
Ordering information Voltage (V) Type 230V AC 400V AC
CDM1-63 CDM1-100 CDM1-225 CDM1-400 CDM1-630 CDM1-800 CDM1-1250
Delixi Electric
Reference MN* CDM163MN230 CDM163MN400 CDM1100MN230 CDM1100MN400 CDM1225MN230 CDM1225MN400 CDM1400MN230 CDM1400MN400 CDM1630MN230 CDM1630MN400 CDM1800MN230 CDM1800MN400 CDM11250MN230 CDM11250MN400
MX* CDM163MX230 CDM163MX400 CDM1100MX230 CDM1100MX400 CDM1225MX230 CDM1225MX400 CDM1400MX230 CDM1400MX400 CDM1630MX230 CDM1630MX400 CDM1800MX230 CDM1800MX400 CDM11250MX230 CDM11250MX400
OF CDM163OF
SD CDM163SD
TR(Round Handle) TS(Square Handle) CDM163TR CDM163TS
CDM1100OF
CDM1100SD
CDM1100TR
CDM1100TS
CDM1225OF
CDM1225SD
CDM1225TR
CDM1225TS
CDM1400OF
CDM1400SD
CDM1400TR
CDM1400TS
CDM1630OF
CDM1630SD
CDM1630TR
CDM1630TS
CDM1800OF
CDM1800SD
CDM1800TR
CDM1800TS
CDM11250OF
35
CDM1L Standard: IEC 60947-2
Function
CDM1L molded case circuit breakers with electronic type residual current operated protection can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit faults To infrequently start and control AC motors To protect users against indirect contact To protect electrical installations against insulation faults (fire hazard, etc)
Description
Technical data Main technical parameters are shown in the table below Type
CDM1L-100
CDM1L-225
CDM1L-400
Frame size rated current A
100
225
400
Rated current In A
16 20 25 32 40
100 125 140 160 200 250 315
50 63 80 100
180 200 225
350 400
Rated frequency Hz
50
Rated insulation voltage Ui V
800
Rated operational voltage Ue V
400
Rated impulse withstand voltage Uimp V
8000
Number of poles
3P, 4P
Icu kA
Type M
50
50
70
(400V)
Type L
35
35
50
Ics kA
Type M
35
35
40
(400V)
Type L
22
22
30
Rated residual
Without delay 30/100/500
30/100/500
100/300/500
100/300/500
100/300/500
100/300/500
100/300/500
100/300/500
1/2 I n
1/2 I n
1/2 I n
Electrical
1500
1000
1000
Mechanical
8500
7000
4000
Total
10000
8000
5000
operating current I
n mA
With delay
Rated residual non-operating current I no mA Durability
Maximum break time for residual operating current protection Number of poles
I n
2I n
5I n
10 I n
Max. break
Without delay
0.2
0.1
0.04
0.04
time S
With delay
0.5/1.15/2.15 0.35/1/2
0.25/0.9/1.9 0.25/0.9/1.9
Table for 4 pole CDM1LE (Neutral line) Code Note
36
A
N(direct connect)
B
N(direct connect N pole lead-make, lag-break)
Delixi Electric
CDM1L Standard: IEC 60947-2
Constructional features Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrent The residual operating current value can be fixed or adjustable The residual operating current protection can be with time-delay or without time-delay Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position indication contact, and tripped position indication contact, for detail see the accessories part
Standard and certification IEC 60947-2 CE
Ordering information
Delixi Electric
37
CDM1L Standard: IEC 60947-2
Type CDM1L-100 3P
4P A
4P B
CDM1L-225 3P
4P A
4P B
CDM1-400
38
3P
Rated current Reference In A Type M 16 CDM1LE100M163 20 CDM1LE100M203 25 CDM1LE100M253 32 CDM1LE100M323 40 CDM1LE100M403 50 CDM1LE100M503 63 CDM1LE100M633 80 CDM1LE100M803 100 CDM1LE100M1003 16 CDM1LE100M164 A 20 CDM1LE100M204 A 25 CDM1LE100M254 A 32 CDM1LE100M324 A 40 CDM1LE100M404 A 50 CDM1LE100M504 A CDM1LE100M634 A 63 80 CDM1LE100M804 A CDM1LE100M1004 A 100 16 CDM1LE100M164 B 20 CDM1LE100M204 B CDM1LE100M254 B 25 CDM1LE100M324 B 32 CDM1LE100M404 B 40 CDM1LE100M504 B 50 63 CDM1LE100M634 B 80 CDM1LE100M804 B 100 CDM1LE100M1004 B 100 CDM1LE225M1003 125 CDM1LE225M1253 140 CDM1LE225M1403 160 CDM1LE225M1603 180 CDM1LE225M1803 200 CDM1LE225M2003 225 CDM1LE225M2253 100 CDM1LE225M1004 A 125 CDM1LE225M1254 A 140 CDM1LE225M1404 A 160 CDM1LE225M1604 A 180 CDM1LE225M1804 A 200 CDM1LE225M2004 A 225 CDM1LE225M2254 A 100 CDM1LE225M1004 B 125 CDM1LE225M1254 B 140 CDM1LE225M1404 B 160 CDM1LE225M1604 B 180 CDM1LE225M1804 B 200 CDM1LE225M2004 B 225 CDM1LE225M2254 B 200 CDM1LE400M2003 250 CDM1LE400M2503 315 CDM1LE400M3153 350 CDM1LE400M3503 400 CDM1LE400M4003
Type L CDM1LE100L163 CDM1LE100L203 CDM1LE100L253 CDM1LE100L323 CDM1LE100L403 CDM1LE100L503 CDM1LE100L633 CDM1LE100L803 CDM1LE100L1003 CDM1LE100L164 CDM1LE100L204 CDM1LE100L254 CDM1LE100L324 CDM1LE100L404 CDM1LE100L504 CDM1LE100L634 CDM1LE100L804 CDM1LE100L1004 CDM1LE100L164 CDM1LE100L204 CDM1LE100L254 CDM1LE100L324 CDM1LE100L404 CDM1LE100L504 CDM1LE100L634 CDM1LE100L804 CDM1LE100L1004 CDM1LE225L1003 CDM1LE225L1253 CDM1LE225L1403 CDM1LE225L1603 CDM1LE225L1803 CDM1LE225L2003 CDM1LE225L2253 CDM1LE225L1004 CDM1LE225L1254 CDM1LE225L1404 CDM1LE225L1604 CDM1LE225L1804 CDM1LE225L2004 CDM1LE225L2254 CDM1LE225L1004 CDM1LE225L1254 CDM1LE225L1404 CDM1LE225L1604 CDM1LE225L1804 CDM1LE225L2004 CDM1LE225L2254 CDM1LE400L2003 CDM1LE400L2503 CDM1LE400L3153 CDM1LE400L3503 CDM1LE400L4003
A A A A A A A A A B B B B B B B B B
A A A A A A A B B B B B B B
Delixi Electric
CDM1L Standard: IEC 60947-2
Type
Rated current In A 4P A 200 225 250 315 350 400 CDM1L-400 4P B 200 225 250 315 350 400
Reference Type M CDM1LE400M2004 CDM1LE400M2254 CDM1LE400M2504 CDM1LE400M3154 CDM1LE400M3504 CDM1LE400M4004 CDM1LE400M2004 CDM1LE400M2254 CDM1LE400M2504 CDM1LE400M3154 CDM1LE400M3504 CDM1LE400M4004
A A A A A A B B B B B B
Overall dimensions
Type L CDM1LE400L2004 CDM1LE400L2254 CDM1LE400L2504 CDM1LE400L3154 CDM1LE400L3504 CDM1LE400L4004 CDM1LE400L2004 CDM1LE400L2254 CDM1LE400L2504 CDM1LE400L3154 CDM1LE400L3504 CDM1LE400L4004
A A A A A A B B B B B B
Unit:mm
Key to overall dimensions Type CDM1L-100L
Poles
3 4 CDM1L-100M 3 4 CDM1L-225L 3 4 CDM1L-225M 3 4 CDM1L-400L,M 3 4
Delixi Electric
Overall size L1 L2 92max 150max 122max 150max 92max 150max 122max 150max 107max 165max 142max 165max 107max 165max 142max 165max 154max 257max 198max 257max
L3 94max 94max 110max 110max 94max 94max 110max 110max 146max 146max
L4 75max 75max 92max 92max 72max 72max 90max 90max 103max 103max
Installation size a b d 30 129 4 4.5 60 129 6 4.5 4.5 30 129 4 4.5 60 129 6 4.5 35 126 4 4.5 70 126 6 4.5 35 126 4 4.5 70 126 6 4.5 88 194 4 6.5 88 194 6
39
CDM1L Standard: IEC 60947-2
Handle mechanism Centrally revolvable type Unit:mm
Square Handle
Dimension for handle mechanism Frame
CDM1L-100
CDM1L-225
CDM1L-400
Dimension
49
55
74
Accessories The accessories are fixed into the circuit breaker.
MN (Undervoltage Release) Technical data Rated operating voltage US(V) Drop-out voltage(V) Pick-up voltage(V)
40
230V, 400V AC (0.35~0.7) Us (0.85~1.1) Us
Delixi Electric
CDM1L Standard: IEC 60947-2
MX (Shunt Release) Technical data Rated control voltage Us(V) Operating voltage(V)
230V, 400V AC (0.7~1.1) Us
OF (Auxiliary Contact) Technical data Rated thermal current Ith 3A Rated operating voltage Us(V) 1NO+1NC (Change over) 2NO+2NC (Change over)
0.4A (400V AC)
SD (Alarm Switch) Technical data Rated thermal current Ith 3A Rated operating voltage Us(V)
0.26A (400V AC) 0.4A (400V AC)
1NO+1NC
Ordering information Voltage (V) 230V AC 400V AC
Type CDM1L-100 CDM1L-225 CDM1L-400
Delixi Electric
Reference MN* CDM1LE100MN230 CDM1LE100MN400 CDM1LE225MN230 CDM1LE225MN400 CDM1LE400MN230 CDM1LE400MN400
MX* CDM1LE100MX230 CDM1LE100MX400 CDM1LE225MX230 CDM1LE225MX400 CDM1LE400MX230 CDM1LE400MX400
SD TS(Square Handle) TR(Round Handle) OF CDM1LE100TR CDM1LE100OF CDM1LE100SD CDM1LE100TS CDM1LE225OF CDM1LE225SD CDM1LE225TS
CDM1LE225TR
CDM1LE400OF CDM1LE400SD CDM1LE400TS
CDM1LE400TR
41
CDW7 Standard: IEC 60947-2
Application Applied to power distribution of AC 50Hz, rated operational voltage 400/690V, rated current 200A~6300A and lower For power distribution and protecting circuit and power supply equipment aganist harm from overload, undervoltage, short circuit, earthing, and other faults Circuit breaker which ampere frame size is under 630A can protect motor aganist overload,undervoltage and shortcircuit Core parts use intelligent control unit which has accurate discrimination protection, it can avoid unnecessary power failure and enhance the reliability of power supply system
Standard and certification International standard: IEC609472 Approved certification: CB, CE, KEMA
Operating condition and installation recommendation Ambient temperature shall be controlled between +40 and -5 , the average temperature in 24 hours shall not exceed +35 Note:contacting manufacturer about circuit breaker used in place where ambient temperature is higher than +40 or lower than -5
42
Delixi Electric
CDW7 Standard: IEC 60947-2
Parameter and characteristics Certification approved: IEC 60947-1 IEC 60947-2 CDW7-1000
CDW7-2000
CDW7-3200
CDW7-6300
3, 4
3, 4
3, 4
3, 4
B
B
B
B
0
0
0
0
400
400/690
400/690
400
690
800
800
800
8000
8000
8000
8000
50
50
50
50
200/400/630
630/800/1000
2000/2500
4000/5000
/800/1000
/1250/1600/2000
/3200
/6300
AC 400V
42
80
100
120
AC 690V
--
50
65
--
AC 400V
30
50
80
100
AC 690V
--
40
50
--
AC 400V
88
176
220
264
AC 690V
--
105
143
--
AC 400V
30
50
65
85
AC 690V
--
40
50
--
9000
9000
4500
1500
1000
1000
500
500
In Icu Ics Icm
Delixi Electric
43
CDW7 Standard: IEC 60947-2
Protection characteristics
Fault and alarm reset button “Fault/Alarm” LED In normal state, this LED is off. In case of fault release, the red LED will flash quickly; in case of alarm, the red LED will be on constantly “Normal” LED As long as the controller is on and operates normally, the green LED always flashes Communication indicator The communication state indication is as follows: Profibus: OFF if no communication; ON if communication exists Modbus: OFF if no communication; flash if communication exists Device Net: Flash if no communication; ON if communication exists Curve LEDs Red LEDs exist behind the curve. In case of fault release, the corresponding LED will flash indicating the fault type; During the parameter setting process, the LED is always on and indicates the current item. Keypad Measure key l, used to switch to the default measurement menu. Set key 2, used to switch to the parameter setting menu. Protection Key 3, used to switch to the protection parameter setting menu. Info key 4, used to switch to the historical record and maintenance menu. Up, Move up the cursor through the menu items on the current level, or increment the value of the selected parameter. Down, Move down the cursor through the menu items on the current level, or decrement the value of the selected parameter. Exit, exit from the current level and return to the upper level, or cancel the current parameter selection. Select, Select to enter into the next level from the current item, or select the current parameter, or store the change.
44
Delixi Electric
CDW7 Standard: IEC 60947-2
Delixi Electric
45
CDW7 Standard: IEC 60947-2
46
Delixi Electric
CDW7 Standard: IEC 60947-2
ECW S- H Different curves
Four phase current (I1,
Up to 8 fault logs
LCD display of
MCR and out-of-limit
available for long time
I2, I 3, IN) and earth
Up to 8 alarm logs
Chinese GUI
tripping protection
delay protection
current
Up to 8 position logs
LED indication
DO Signal alarm function
Different curves
Thermal capacity
Historical current peak
Key operation
Communication function
available for inverse
Contact equivalence
short time delay protec-
Number of operating
tion
cycles
Definite short time delay
Clock function
protection
Self-diagnosis function
Instantaneous protection Current unbalance (open phase) protection Earth protection Earth fault alarm Neutral phase protection Load monitor ECW - M
Long time delay protec-
Max. phase current
Fault log
Digital display
DO Signal alarm function
tion
Four phase current (I1,
Self-diagnosis
LED indication
MCR and out-of-limit
Definite time delay +
I2, I 3, IN) and earth
function
Key operation
tripping protection
inverse time delay for
current
Feature test
Digital setting of
Earth fault or leakage
function
protection param-
protection (either)
short time delay protec-
eters
tion Instantaneous protection Earthing protection Load monitor ECW - H
Different curves
Four phase current (I1,
Up to 8 fault logs
LCD display of
Over-voltage protection
available for long time
I2, I 3, IN) and earth
Up to 8 alarm logs
Chinese GUI
Under-voltage protection
delay protection
current
Up to 8 position logs
LED indication
Voltage unbalance
Different curves
Thermal capacity
Historical current
Key operation
protection
available for inverse
peak
Over-currency protection
short time delay protec-
Contact equivalence
Under-frequency
tion
Number of operating
protection
Definite short time delay
cycles
Phase protection
protection
Fault clock function
Inverse power protection
Instantaneous protection
Self-diagnosis fault
Demand protection
MCR and out-of-limit
log
Zonal system interlock
tripping protection
Self-diagnosis
protection
Current unbalance (open
function
Communication function
phase) protection
Feature test
Earth protection
function
Earth fault alarm Neutral phase protection Load monitor
Delixi Electric
47
CDW7 Standard: IEC 60947-2
CDW7-1000
CDW7-2000~6300
ECWS-H intelligent control-
ECW-M intelligent controllers ECW-H intelligent controllers
lers
1.05 1.3 1.5Ir1
Ir h Ir h
Ir=(0.4~1)ln
Ir=(0.4~1)ln
15%
10%
10%
2h
2h
2h
2h
Ir=(0.4~1)ln
1h
8,12.8,19.2,32,48,64,80,
1h 15,30,60,120,240,360,480,
15,30,60,120,240,480
108,144,224,320,480,640,
600,720,840,960
800,960,1120 2.0Ir1
3.32,5.32,8.00,13.32,20.00, 8.4,16.9,33.8,67.5,135,270
8.4,16.9,33.8,67.5,135,202.
26.66,33.30,45.00,60.00,
5,270,337.5,405,472.5,540
93.32,133,200,266,333, 400,433 3.0Ir1
1.25,2.00,3.00,5.00,7.50, 10.0,12.5,16.8,22.5,35.0, 50.0,75.0,100,125,150,162 10% Ir2=(1.5~15)In
Ir2=(1.5~15)In
Ir2=(0.4~15)In
15% Ts=K/10(N2-1),(Ts
15%
15%
10%
10% I2Ts= 8Ir1)2ts
Ts=K/10(N2 -1),(Ts
0.1,0.2,0.3,0.4
0.1,0.2,0.3,0.4
0.1,0.2,0.3,0.4
0.06,0.13,0.2,0.27
0.06,0.16,0.25,0.34
0.06,0.13,0.2,0.27
20ms)
10% CDW7-1000 (1.0~20)ln 15% Ir4=(0.2~1.0)In 10% 0.1s~1s (Rank difference 0.1s)
15%
15%
ECWS-H
ECW-M CDW7-2000
20ms)
ECW-H
CDW7-3200
CDW7-6300
Ir3=1In~50KA+OFF Ir3=1In~75KA+OFF IIr3=1In~100KA+OFF 15% Ir4=(0.2~1.0)In
15%
15%
Ir4=(0.2~1.0)In
10% 0.1~4s (Rank difference 0.1s)
0.1s~1s (Rank difference 0.1s)
15%
48
Delixi Electric
CDW7 Standard: IEC 60947-2
Auxiliary functions
AC 380V
AC220V
(0.35~0.7)Ue
(0.35~0.7)Ue
(0.85~1.1)Ue
(0.85~1.1)Ue 0.35Ue
0.35Ue 36VA
24VA
5VA
5VA
110
70 AC380
AC220
DC220
36VA
24VA
24W
DC110 24W
5VA
5VA
5W
5W
(0.7~1.1)Us less than 30ms
7-2000~6300
AC380
AC220
DC220
DC110
36VA
24VA
24W
24W
10VA
10VA
10W
10W
(0.85~1.1)Us less than 70ms
Delixi Electric
49
CDW7 Standard: IEC 60947-2
AC380
AC220
DC220
CDW7-
In
2000A
85VA
85VA
85VA
85VA
2000~6300 2000A 3200A
In
3200A
110VA
110VA
110VA
110VA
In
6300A
150VA
150VA
150VA
150VA
80VA
80VA
80VA
80VA
CDW7-1000
DC110
(0.85~1.1)Us less than 5s
U/Ue cos
Pe
50
DC-13
10
1
1
1
1
1
0.3
6Pe
I/Ie
10
1.1
U/Ue
1.1
1.1
0.3
6Pe
10
10
cos
0.95
AC-15
T0.
50W T0.95e’s upper limit
300ms
Delixi Electric
CDW7 Standard: IEC 60947-2
Overall and mounting dimension
CDW7-1000A fixed circuit breaker outline and horizonal/vertical connected dimension L L1 200, 400 266 244 630 266 244 800, 1000 266 244 200, 400 336 314 630 336 314 800, 1000 336 314 Delixi Electric
L2 70 70 70
N 6 12 12 8 16 16 51
CDW7 Standard: IEC 60947-2
CDW7-1000A drawout type circuit breaker outline and horizonal/vertical wiring 200, 400 630 800, 1000 200, 400 630 800, 1000 52
3P
4P
L 284 284 284 354 354 354
L1 194 194 194 264 264 264
Unit:mm L2 70 70 70
L3 55 75 75 55 75 75
L4 63 83 83 63 83 83
n 6 12 12 8 16 16
H 6 8 10 6 8 10 Delixi Electric
CDW7 Standard: IEC 60947-2
CDW7-2000A~3200A
CDW7-2000A fixed circuit breaker vertical connection diagram
CDW7-2000A~3200A fixed circuit breaker overall and horizonal/vertical wiring CDW7-2000
CDW7-3200
Unit:mm
L1
L2
L3
L4
In A
3P
362
318
292
340
400~800
4P
457
413
292
435
1000~1600
457
413
292
435
2000
3P
422
378
352
400
2000~2500
4P
537
493
352
515
3200
a 10 15 20 20 30
CDW7-2000 mounting dimension is same regardless of different current used in"horizonal-wiring" or"vertical-wiring"
Delixi Electric
53
CDW7 Standard: IEC 60947-2
CDW7-2000A~6300A
CDW7-2000A drawout circuit breaker vertical connection diagram
CDW7-2000A~6300A drawout type circuit breaker outline and horizonal/vertical connection CDW7-2000
CDW7-3200
CDW7-6300 (4000/5000A) CDW7-6300
3P 4P 3P 4P 4000A 3P 4P 3P
L1 375 375 470 435 550 550 813 928 928
L2 335 335 430 395 510 510 773 888 888
L3 292 292 292 352 352 352 352 352 352
L4 265 265 360 325 440 440 703 818 818
L5 247 247 247 307 307 307 307 307 307
W1 461 461 461 471 471 494 494 494 494
Unit:mm W2 507 507 507 517 517 540 540 540 540
b 179 179 179 189 189 212 212 212 212
In A 400~800 1000~1600 2000 2000~2500 3200~4000 3200~4000 4000 5000~6300 5000~6300
a 10 15 20 20 30 30 20 30 30
W7-3200 can expand to 4000A,which mounting dimension is as same as 4P of CDW7-3200 DW7-2000 the mounting dimension is same regardless of different current used in"horizonal-connected" or "vertical-connected" 54
Delixi Electric
CDW7 Standard: IEC 60947-2
CDW7-1000
CDW7-1000A
CDW7-1000A
CDW7-2000~6300
CDW7-2000~6300A
CDW7-2000~6300A
CDW7-2000~6300 panel cut-out dimension and mounting dimension a
b
Unit:mm c 3P
4P
CDW7-2000
306
346
0
47.5
CDW7-3200
366
406
0
57.5
CDW7-6300
366
406
189(4000/5000A)
246.5(4000/5000A)
246.5(6300A)
--
Delixi Electric
55
CDW7 Standard: IEC 60947-2
Auxiliary connection diagramn
F X with different current ratings shall connect with different sources.
41 42 when controller power choose DC,the output is DC24V,user can select DC power module 43 44 circuit breaker status detection terminal(used when MCR function included) 45 overload pre-alarm signal output 46 automatic diagnosis alarm signal output 47 fault trip alarm signal output 48 earthing but non-tripping,only alarm signal output 49 four groups of contacts output common terminal 50 51 externally sensor input terminal 58 able to directly connect to power supply(automatic pre-energization),also able to join up with normal open pushbutton to connect to power supply(manual preenergization)
56
Delixi Electric
CDW7 Standard: IEC 60947-2
Pin functions: Pin 1# and 2#: Auxiliary power input,pin 1# is positive for DC input Pin 3#, 4#, 5#: Fault trip contact output (4# is common terminal); contact capacity: AC380V, 16A Pin 6# and 7#, 8# and 9#: Two groups of auxiliary contacts for breaker status; contact capacity: AC380V, 16A 12#,13#(Contact1)and 14#,15#(Contact2)and 16#, 17#(Contact3)and 18#,19#(Contact4):Output of four groups of signal for controllers,contact capacity:4A/240V 7A/24VDC 20#: Earth protection 21#~24#:input of voltage signal (Note:the order cant be wrong) Components: Q - Under-voltage release F - Shunt release X – Closing electromagnet DF - Auxiliary switch M - Motor SB1—Button for closing SB2—Button for shunt
Delixi Electric
Note: 1. If the control voltage values of Q, F, X, and M are different to each other, these components can be connected to different power supply units; in the application, the shunt release and closing electromagnet shall be connected serially with normally open and normally closed auxiliary contacts (the part enclosed by dotted lines shall be connected by the user; the part represented by a two-dot chain line is the wiring of circuit 51); Note 2: The pin 35# can be connected to the power supply directly (automatic pre-energy storage) or connected serially to a normally open button and then to the power supply (manual pre-energy storage); Note 3: If the user requests, pin #6~#7 can be connected to normally closed contacts; Note 4: The ECW power supply module I is a DC power supply module, and it can be omitted if the power supply is AC power supply; the polarity and lead-ins/ lead-outs shall not be reversed (for draw-out type circuit breakers, the lead-outs of the power supply module has been connected before the circuit break is shipped from the factory); Note 5: In case of circuit 47, the auxiliary contacts are four closed and four open contacts; pin #25 and #26 are input terminals of an external current transformer , used for earth fault protection as (3P+N)T type ; Note 6: In case of circuit 51, the auxiliary contacts are six closed and six open contacts (or five closed and five open contacts); pin #25, #26, and #51 form normally open and normally closed contacts; Note 7: If Profibus or any other protocol is used, ECW-H + DP conversion module and other conversion modules must be ordered; ECW power supply module lV and ECW201 relay module must be ordered separately; Note 8:Pin #12~#19 input/output contacts can be user-defined programmable signal contacts.
57
CDW7 Standard: IEC 60947-2
1
2: terminal 35# can directly connect to power supply (automatic pre-energy storage),or join up with normal open pushbutton to connect power supply(manual pre-energy storage) 3: terminal 6#~7# can lead out normal close contact if user suggested 4: ECW power supply module is DC power supply module, the module doesn't exist when power supply current is AC, polarity,incoming line and leading-out line shall not connected reversely(leading-out terminal of power supply module in drawout type had been connected before sale) 5: in 47 circuit,auxiliary contact is 4 open 4 close;25# 26# is input terminal of external sensor 6: in 51 circuit,auxiliary contact is 6open6close(5open 5close);25#
26# 51# form normal open normal close
contact(earth-leakage protection excluded) 7: if using profibus or other protocols, user shall order ECW-H+HP transformation module and others;ECW power supply moduleV,ECW201 relay module and others shall order seperately
1# 2#: 1# is the front terminal when DC is supplied by auxiliary power 3# 4# 5 AC380V 16A 6# 7# 8# 9#: two groups of circuit breaker status auxiliary terminal: AC380V 16A 10# 11#: respectively as the communication leading-out of RS485A ,RS485B 12#: overload pre-alarm signal output 13#: communication remote control shunt release output 14#: communication remote control closing output or instantaneous short time-delay trip signal output 15#: communication remote control energy storage or long time-delay trip signal output 16#: S-earth(RS-485 transmissionn common ground wire 17#: load monitor output1 18#: load monitor signal 2 19#: signal output common earth wire 20#: PE line ,shield earth wire 21#: neutral voltage signal N phase 22#: voltage signal A phase 23#: voltage signal B phase 24#: voltage signal C phase
8: #12~#19 output input contacts are programmableselfdefined signal contaccts
58
Delixi Electric
CDW7 Standard: IEC 60947-2
Other additional parameter
Delixi Electric
59
CDW7 Series Air Circuit Breakers
Order Instructions
Customer
Sets purchased
Date
Mode CDW7
Fixed
Draw-out
Rated voltage
AC400
AC690
H Type Intelligent electronic trip
Basic function
3 Poles
4Poles
Rated current
In= A
Overload long delay
Short-circuit short
Short-circuit instantaneous
time protection
delay time protection
protection
Load monitoring function
Metering function
Earthing protection
(Not available for L type)
Power supply
AC 230V
AC 400V
DC 220V
DC 110V
Under-voltage instantaneous trip
AC 230V
Under-voltage time-delay trip
1s
AC 400V
Under-voltage trip 3s
5s
Accessaries
Shunt trip
AC 230V
AC 400V
DC 220V
DC 110V
Energy releasing electromagnet
AC 230V
AC 400V
DC 220V
DC 110V
Motor Driven
AC 230V
AC 400V
DC 220V
DC 110V
Interphase barrier
Escutcheon
N phase external connection
Earth-leakage CT(Only for cable)
Auxiliary switch
standard(4a4b)
special(6a6b)
Auxiliary Connection Terminal Mechanical interlock
1-lock,1-key
2-lock,1-key
3-lock,1-key
Steel-cable interlock
Interlocking rod with 2 switches
Interlocking rod with 3 switches
Door interlock(Available for Draw-out type)
Note:for any special requirement,please contact with the manufacturer.
60
Delixi Electric
CDC17 Standard: IEC 60947-4-1
Function
Description
Technical data Main circuit Rated insulation voltage: 690 V Rated operational voltage: up to 660 V Frequency limits: 50/60 Hz Rated operational current and power of controlled motors are shown in the table below Control circuit Control circuit supply voltage Us: AC 36V, 110V, 127V, 220/230V, 380/400V DC 110V, 220V Technical features Compact, light, low consumption, long-life durability Flame-resistant enclosure ensures a safe & reliable service Full range auxiliaries: - auxiliary contact module - time delay module - mechanical interlock module Direct connection with thermal overload relay to form electomagnetic starter
Standard and certification IEC 60947-4-1 KEMA, CE
Delixi Electric
61
CDC17 Standard: IEC 60947-4-1
Overall dimensions
CDC17-9~32
CDC17-40~95
CDC17-115~150
CDC17-185~330
CDC17-400~500
CDC17-630~1000
Installation dimensions
unit:mm
Type
Amax
Bmax
Cmax
C1max
C2max
a
CDC17-9~12
45
68
77
109
133
35
0.21
59
0.28
4.5
CDC17-18
45
68
82
115
138
CDC17-25
56.5
79
91
124
149
40
0.21
66
0.43
4.5
CDC17-32
56.5
79
95
127
152
CDC17-40~65
75
127
115
145
170
40
0.21
105
CDC17-80~95
85
127
123
153
178
Note:C1max-Contactor+CDF4
b
c
0.57
6.5
C2max-Contactor+CDLA
Type
A
A1
B
C
C1
a1
a2
a3
b1
b2
CDC17-185
138
111
180
163
95
40
20
80
158
154
9
150
7
CDC17-225
138
111
199
163
95
48
25
80
172
172
11
150
7
CDC17-265, 330
171
144
207
201
119
48
25
96
180
180
11
166
11
62
b3
1
Delixi Electric
CDC17 Standard: IEC 60947-4-1
Characteristics Model Rated operational current A
380V / 400V 660V
AC-3 AC-4 AC-3 AC-4
Rated operational voltage V Rated insulation voltage V Rated conventional thermal current A Power of controlled 3-phase cage motor(AC-3) 380V/400V kW 660V AC-3 Electric durabilities(x104 operations) Operating rate(cycles/h) Electric durabilities(x104 operations) Operating rate(cycles/h) Mechanical durabilities(x104 cycles) AC Coil Coil voltage V AC-4
Accessories
Operational voltage V Drop-out voltage V Inrush VA Sealed VA Heat dissipation W Auxiliary contact Time-delay block Mechanical Interlock
Matched Relay Matched Fuse Cross Section of Cable mm2 Weight Kg
Delixi Electric
Number of Piece Flexible cable Inflexible cable
Front mount Side mount Front mount
CDC17-9 CDC17-12 9 12 3.5 5 6.6 8.9 1.5 2 380 / 400 660 690 20 4 5.5 5.5 7.5 100 1200 20 300 1000 36, 48, 110, 220, 380 85%~110%Us 20%~75%Us 70 8 1.8~2.7 CDF4 CDLA2 or CDLA3 CDJL17-1 CDR17-18 RT16-20 1 2 1 2 2.5 4 0.315
CDC17-18 18 7.7 12 3.8
CDC17-25 25 8.5 18 4.4
CDC17-32 32 12 21 7.5
32 7.5 9
40 11 15
50 15 18.5 80
800
110 11 3~4
RT16-32 1 2 4 6 0.335
CDR17-32 RT16-40 1 2
0.513
RT16-50 1 2 6 10 0.510
63
CDC17 Standard: IEC 60947-4-1
Model Rated operational current A
380V / 400V 660V
AC-3 AC-4 AC-3 AC-4
Rated operational voltage V Rated insulation voltage V Rated conventional thermal current A Power of controlled 3-phase cage motor(AC-3) 380V/400V kW 660V AC-3 Electric durabilities(x104 operations) Operating rate(cycles/h) Electric durabilities(x104 operations) Operating rate(cycles/h) Mechanical durabilities(x104 cycles) AC Coil Coil voltage V AC-4
Accessories
Operational voltage V Drop-out voltage V Inrush VA Sealed VA Heat dissipation W Auxiliary contact Time-delay block Mechanical Interlock
Matched Relay Matched Fuse Cross Section of Cable mm2 Weight Kg
64
Number of Piece Flexible cable Inflexible cable
Front mount Side mount Front mount
CDC17-40 CDC17-50 40 50 18.5 24 34 39 9 12 380 / 400 660 690 60 80 18.5 22 30 33 80 1200 20 300 800 36, 48, 110, 220, 380 85%~110%Us 20%~75%Us 200 20 6~10 CDF4 CDLA2 or CDLA3 CDJL17-2 CDR17-95 RT16-63 RT16-80 1 2 1 2 10 16 16 25 1.14
CDC17-65 65 28 42 14
CDC17-80 80 37 49 17.3
30 37
125 37 45 60
CDC17-95 95 44 55 21.3
45
600
RT16-100 1 2 25 25 -
RT16-125 1 2 50 25 50 1.35
RT16-200 1 2 50 25 50 -
Delixi Electric
CDC17 Standard: IEC 60947-4-1
Model Rated operational current A
380V / 400V 660V
AC-3 AC-4 AC-3 AC-4
Rated operational voltage V Rated insulation voltage V Rated conventional thermal current A Power of controlled 3-phase cage motor(AC-3) 380V/400V kW 660V AC-3 Electric durabilities(x104 operations) Operating rate(cycles/h) Electric durabilities(x104 operations) Operating rate(cycles/h) Mechanical durabilities(x104 cycles) AC Coil Coil voltage V AC-4
Accessories
Operational voltage V Drop-out voltage V Inrush VA Sealed VA Heat dissipation W Auxiliary contact Time-delay block Mechanical Interlock
Matched Relay Matched Fuse Cross Section of Cable mm2 Weight Kg
Delixi Electric
Number of Piece Flexible cable Inflexible cable
Front mount Side mount Front mount
CDC17-115 CDC17-150 115 150 52 60 86 110 49 61 380 / 400 660 690 150 55 75 80 100 60 1200 20 300 600 36, 48, 110, 220, 380 85%~110%Us 20%~75%Us 559 33 9.5 CDFC17-11,CDFC17-12 CDJL17-3 CDR17-185 RT16-200 1 2 1 2 95 50 120 20x3 25x3 2.15
CDC17-185 185 79 118 69
CDC17-225 225 85 135 82
CDC17-265 265 105 170 98
CDC17-330 330 117 225 118
210 90 110
225 110 129
300 132 160
300 160 220
300 30 600
1198 83 18.9
695 45 13.5
RT16-250 1 2 150 25x3
JR20-250 RT16-250 1 2 185 32x4
JR20-400 RT16-400 1 2 240 32x4 6.6
1 240 6.6
2 30x5
65
CDC17 Standard: IEC 60947-4-1
Model Rated operational current A
380V / 400V 660V
AC-3 AC-4 AC-3 AC-4
Rated operational voltage V Rated insulation voltage V Rated conventional thermal current A Power of controlled 3-phase cage motor(AC-3) 380V/400V kW 660V AC-3 Electric durabilities(x104 operations) Operating rate(cycles/h) Electric durabilities(x104 operations) Operating rate(cycles/h) Mechanical durabilities(x104 cycles) AC Coil Coil voltage V AC-4
Accessories
Operational voltage V Drop-out voltage V Inrush VA Sealed VA Heat dissipation W Auxiliary contact Time-delay block Mechanical Interlock
Matched Relay Matched Fuse Cross Section of Cable mm2 Weight Kg
66
Number of Piece Flexible cable Inflexible cable
Front mount Side mount Front mount
CDC17-400 CDC17-500 400 500 138 147 305 355 135 145 380 / 400 660 690 500 220 265 280 335 60 300 20 30 600 110, 220, 380 85%~110%Us 20%~75%Us 780 10 8 CDFC17-21 JR20-400 JR20-630 RT16-500 RT16-630 2 150 185 30x5 40x5 9.36
CDC17-630 630 188 460 170
CDC17-800 800 242 530 215
CDC17-1000 1000 580 -
800 335 450
450 500
1000 560 560
600
1050 12 10
RT16-800 240 50x5 22.8
RT17-4/1000
RT17-4/-1250
60x5
80x5
Delixi Electric
CDC17 Standard: IEC 60947-4-1
Ordering information Rate current (A)
Contact blooks NO NC 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
9 12 18 25 32 40 50 65 80 95 115 150 185 225 265 330 400 500 630 800 1000
coil voltage code coil voltage (V)
frequency code frequency
Delixi Electric
36 C
50Hz 5
48 E
Reference CDC17910 CDC17901 CDC171210 CDC171201 CDC171810 CDC171801 CDC172510 CDC172501 CDC173210 CDC173201 CDC174011 CDC175011 CDC176511 CDC178011 CDC179511 CDC1711522 CDC1715022 CDC1718522 CDC1722522 CDC1726522 CDC1733022 CDC1740022 CDC1750022 CDC1763022 CDC1780022 CDC17100022
110 F
220 M
380 Q
60Hz 6
67
CDC17 Standard: IEC 60947-4-1
Description
Application scope
CDF4-20 Top auxiliary contact
CDF420
CDF4-11 Top auxiliary contact
CDF411
CDF4-02 Top auxiliary contact
CDF402
CDF4-22 Top auxiliary contact
CDF422
CDF4-13 Top auxiliary contact
CDC17-9~95A
CDF413
CDF4-31 Top auxiliary contact
CDF431
CDF4-04 Top auxiliary contact
CDF404
CDF4-40 Top auxiliary contact
CDF440
CDLA2 On delay 0.1~3S
CDFC1711
CDLA2 On delay 0.1~30S CDLA2 On delay 10~180S
CDFC1712 CDC17-9~95A
CDFC1721
CDLA3 off delay 0.1~3S
CDLA2ON0
CDLA3 off delay 0.1~30S
CDLA2ON2
CDLA3 off delay 10~180S
68
Reference
CDLA2ON4
CDFC17-11 Side auxiliary contact
CDC17-115~330A
CDLA3OFF0
CDFC17-12 Side auxiliary contact
CDC17-115~330A
CDLA3OFF2
CDFC17-21 Side auxiliary contact
CDC17-400~1000A
CDLA3OFF4
CDJL17-1 Mechanical interlocking module CDC17-9~32A
CDJL171
CDJL17-2 Mechanical interlocking module CDC17-40~95A
CDJL172
CDJL17-3 Mechanical interlocking module CDC17-115~330A
CDJL173
Delixi Electric
CDR17 Standard: IEC 60947-4-1 60947-5-1
Function
CDR17 series thermal overload relays provide: Protection of circuits and motors against overload Protection of circuits and motors against phase loss Motor starters installation in association with contactors
Description
Technical data Main circuit: Frequency limits: 50/60 Hz Rated insulation voltage: 690 V Rated operational voltage: up to 690 V Frame size rated current: 18, 32, 95, 185A Rated operational current and range of current setting are shown in the table below Table 1 Type
Rated insulation voltage Ui V
CDR17-18 690
CDR17-32 690
Delixi Electric
Frame Rated Thermal protection size current No Rated Range of rated Ie A current current current setting A setting A
Reference
18
32
18
32
1801
0.15
0.1~0.13~0.15
CDR1718P15
1802
0.18
0.12~0.16~0.18
CDR1718P18
1803
0.25
0.18~0.2~0.25
CDR1718P25
1804
0.36
0.25~0.32~0.36
CDR1718P36
1805
0.5
0.35~0.4~0.5
CDR1718P5
1806
0.7
0.5~0.6~0.7
CDR1718P7
1807
0.9
0.63~0.72~0.9
CDR1718P9
1808
1.2
0.9~1~1.2
CDR17181P2
1809
1.8
1.2~1.6~1.8
CDR17181P8
1810
2.5
1.8~2~2.5
CDR17182P5
1811
3.6
2.5~3.2~3.6
CDR17183P6
1812
4.8
3.5~4~4.8
CDR17184P8
1813
6.3
4.5~5~6.3
CDR17186P3
1814
7
5~6~7
CDR17187
1815
9
6.3~7.2~9
CDR17189
1816
12
9~10~12
CDR171812
1817
15
11~13~15
CDR171815
1818
18
14~16~18
CDR171818
3201
6.3
4.5~5~6.3
CDR17326P3
3202
7
5~6~7
CDR17327
3203
9
6.3~7.2~9
CDR17329
3204
12
9~10~12
CDR173212
3205
18
12~16~18
CDR173218
3206
25
18~20~25
CDR173225
3207
32
23~25~32
CDR173232
69
CDR17 Standard: IEC 60947-4-1 60947-5-1
Type
Frame Rated Thermal protection current No size Rated Range of Ie A rated current current current setting A setting A
Reference
CDR17-95 690
95
CDR17-185 690
185
95
185
9501
12
9~10~12
CDR179512
9502
18
12~16~18
CDR179518
9503
25
18~20~25
CDR179525
9504
32
23~25~32
CDR179532
9505
40
30~36~40
CDR179540
9506
50
37~45~50
CDR179550
9507
65
48~55~65
CDR179565
9508
70
55~63~70
CDR179570
9508
80
63~70~80
CDR179580
9510
95
75~90~95
CDR179595
8501
50
37~45~50
CDR1718550
8502
65
48~55~65
CDR1718565
8503
70
55~63~70
CDR1718570
8504
80
63~70~80
CDR1718580
8505
95
75~90~95
CDR1718595
8506
115
90~100~115
CDR17185115
8507
135
105~115~135
CDR17185135
8508
150
120~135~150
CDR17185150
8509
160
130~150~160
CDR17185160
8510
185
150~160~185
CDR17185185
Table 2 Basic data for control circuit and auxiliary circuit Rated Conventional Circuit insulation free air thermal type voltage V current A 690
6
Utilization Rated Rated Rated category frequency operational current Hz voltage V A
Control AC-15
50
circuit DC-13 Auxiliary AC-15
50
circuit
Rated control capacity
220(230)
1.64(1.57) 360 VA
380(400)
0.95(0.90)
660(690)
0.55(0.52)
220(230)
0.23(0.22) 50 W
220(230)
6
380(400) 660(690) DC-13
220(230)
Table 3 Limits of operation of relays when energized on all poles Sequence Multiples of Tripping time current setting
Initial condition
Ambient air temperature
1
1.05
Non-trip within 2 hours
From cold
+20 oC
2
1.2
<2h
From hot(immediately
3
1.5
Trip
<2min
following sequence 1
<4min
test)
10A
2s<TP²10s
From cold
10
4s<TP²10s
10A
class 10 4
70
7.2
Delixi Electric
CDR17 Standard: IEC 60947-4-1 60947-5-1
Table 4 Limits of operation when energized on two poles Sequence Multiples of current setting Tripping time Initial condition Any two poles The third-pole
Ambient air temperature
1
1.0
0.9
+20 oC
2
1.15
0
Non-trip
From cold state
within 2 hours <2h
From hot state (immediately following sequence 1 test)
Table 5 Temperature compensation characteristic Sequence
Multiples of Tripping time Initial condition current setting
Ambient air temperature
1
1.0
>2h
From cold state
+55 oC
2
1.2
<2h
From hot state(immediately
3
1.05
>2h
From cold state
4
1.30
<2h
From hot state(immediately
5
0.95
>2h
From cold state
6
1.2
<2h
From hot state(immediately
7
1.05
>2h
From cold state
8
1.35
<2h
From hot state(immediately
following sequence 1 test) -10 oC
following sequence 3 test) +60 oC
following sequence 5 test) -20 oC
following sequence 7 test)
Overall dimensions
CDR17-18
Delixi Electric
71
CDR17 Standard: IEC 60947-4-1 60947-5-1
CDR17-32
CDR17-95
CDR17-185
72
Delixi Electric
LMK Current Transformer Standard: BS7626, IEC44-1
Function
LMK Current Transformer provide: Measuring current
Description
Technical Data Primary current: 100A-5000A Secondary approval: 5A, 1A Maximum voltage: 0.66kV Class: 0.5, 1.0, 3.0 Short time thermal current: Ith=100Ih Rated security coefficient: FS<5
Standard and Certification BS7626, IEC44-1
Overall dimensions
Unit: mm
Delixi Electric
Model
H
W
D
LMK-0.66-20
87
68
42
LMK-0.66-30
79
60
37
LMK-0.66-40
99
75
40
LMK-0.66-50
99
82
40
LMK-0.66-60
126
102
40
LMK-0.66-80
118
125
40
LMK-0.66-100
136
170
40
LMK-0.66-120
136
190
41
73
LMK Current Transformer Standard: BS7626, IEC44-1
Class: 0.5 Maximum Voltage: 0.66KV Model
Current ratio Rated Load Bar (VA) (A) (mm)
30/5 50/5 75/5 100/5 100/5 150/5 200/5 LMK-0.66-30 100/5 200/5 250/5 300/5 LMK-0.66-40 250/5 300/5 400/5 500/5 LMK-0.66-50 300/5 400/5 500/5 600/5 750/5 800/5 1000/5 LMK-0.66-60 500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 LMK-0.66-80 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 LMK-0.66-100 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 3000/5 LMK-0.66-120 1500/5 2000/5 2500/5 3000/5 4000/5 5000/5 LMK-0.66-20
74
5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 20-3.75 15-3.75 15-3.75 20-3.75 20-3.75 25-3.75 25-3.75
30 30 30 40 40 40 40 50 50 50 50 50 50 50 60 60 60 60 60 60 60 80 80 80 80 80 80 80 80 100 100 100 100 100 100 100 100 100 120 120 120 120 120 120
10 10 10 10 10 10 10 10 10 10 10 10 10 10 20 20 20 20 20 20 20 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80
Diameter Number of Turns Reference through the core (mm)
30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 35 35 35 35 35 35 35 45 45 45 45 45 45 45 50 50 50 50 50 50 50 50 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
5 3 2 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
LMKP63020 LMKP65020 LMKP67520 LMKP610020 LMKP610020 LMKP615020 LMKP620020 LMKP610030 LMKP620030 LMKP625030 LMKP630030 LMKP625040 LMKP630040 LMKP640040 LMKP650040 LMKP630050 LMKP640050 LMKP650050 LMKP660050 LMKP675050 LMKP680050 LMKP6100050 LMKP650060 LMKP660060 LMKP675060 LMKP680060 LMKP6100060 LMKP6120060 LMKP6150060 LMKP660080 LMKP675080 LMKP680080 LMKP6100080 LMKP6120080 LMKP6150080 LMKP6200080 LMKP6250080 LMKP6600100 LMKP6750100 LMKP6800100 LMKP61000100 LMKP61200100 LMKP61500100 LMKP62000100 LMKP62500100 LMKP63000100 LMKP61500120 LMKP62000120 LMKP62500120 LMKP63000120 LMKP64000120 LMKP65000120
Delixi Electric
LMK Current Transformer Standard: BS7626, IEC44-1
Class: 1 Maximum Voltage: 0.66KV Model LMK-0.66-20
Current ratio Rated Load Bar (VA) (A) (mm)
30/5 50/5 75/5 100/5 150/5 200/5 LMK-0.66-30 100/5 200/5 250/5 300/5 LMK-0.66-40 250/5 300/5 400/5 500/5 600/5 LMK-0.66-50 300/5 400/5 500/5 600/5 750/5 800/5 1000/5 1200/5 LMK-0.66-60 500/5 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 LMK-0.66-80 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 LMK-0.66-100 600/5 750/5 800/5 1000/5 1200/5 1500/5 2000/5 2500/5 3000/5 LMK-0.66-120 1500/5 2000/5 2500/5 3000/5 4000/5 5000/5
Delixi Electric
5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 5-3.75 10-3.75 5-3.75 5-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 5-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75 15-3.75 15-3.75 20-3.75 20-3.75 15-3.75 15-3.75 20-3.75 20-3.75 25-3.75 25-3.75
30 30 30 40 40 40 40 40 50 50 50 50 50 50 50 60 60 60 60 60 60 60 60 60 80 80 80 80 80 80 80 80 100 100 100 100 100 100 100 100 100 120 120 120 120 120 120
10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 20 20 20 20 20 20 20 20 20 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 60 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80 10 or 80
Diameter Number of Turns through the core Reference (mm)
30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 35 35 35 35 35 35 35 35 45 45 45 45 45 45 45 45 50 50 50 50 50 50 50 50 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
5 3 2 2 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
LMKP6P13020 LMKP6P15020 LMKP6P17520 LMKP6P110020 LMKP6P115020 LMKP6P120020 LMKP6P110030 LMKP6P120030 LMKP6P125030 LMKP6P130030 LMKP6P125040 LMKP6P130040 LMKP6P140040 LMKP6P150040 LMKP6P160040 LMKP6P130050 LMKP6P140050 LMKP6P150050 LMKP6P160050 LMKP6P175050 LMKP6P180050 LMKP6P1100050 LMKP6P1120050 LMKP6P150060 LMKP6P160060 LMKP6P175060 LMKP6P180060 LMKP6P1100060 LMKP6P1120060 LMKP6P1150060 LMKP6P1200060 LMKP6P160080 LMKP6P175080 LMKP6P180080 LMKP6P1100080 LMKP6P1120080 LMKP6P1150080 LMKP6P1200080 LMKP6P1250080 LMKP6P1600100 LMKP6P1750100 LMKP6P1800100 LMKP6P11000100 LMKP6P11200100 LMKP6P11500100 LMKP6P12000100 LMKP6P12500100 LMKP6P13000100 LMKP6P11500120 LMKP6P12000120 LMKP6P12500120 LMKP6P13000120 LMKP6P14000120 LMKP6P15000120
75
RT16 Fuse Standard: IEC 60269
Function
Description
RT16 fuse provide: Protection of circuits against overload current Protection of circuits against short-circuit current
Technical Data Rate current range:2-630A Rate voltage:500/660V Rate breaking capacity:120KA(500V),50KA(660V)
Standard and certification IEC60269 CE
Overall dimensions
Type
RT16-00
RT16-1
RT16-2
RT16-3
a
78.5
135
150
150
b
29
48
58
67
c
57
62
72
85
d
49
67
67
67
e
6
6
6
6
A
30
58
64
64
B
120
200
250
250
C1
61
83
99
105
C2
85
96
112
120
D
100
175
200
210
E
25
25
25
25
F
7.5
10.5
10.5
10.5
30
30
30
G
76
Delixi Electric
RT16 Fuse Standard: IEC 60269
Ordering information Fuse-link Rate current In(A) Suitable fuse bases RT16-00
2
RT16-00
Weight(g) 170
RT16004
6
RT16006
8
RT16008
10
RT160010
12
RT160012
16
RT160016
20
RT160020
25
RT160025
32
RT160032
40
RT160040
50
RT160050
63
RT160063
80
RT160080
100
RT1600100
125
RT1600125
80
RT1600160 RT16-1
450
RT161100
125
RT161125
160
RT161160
200
RT161200
125
RT161250 RT16-2
660
RT162160
200
RT162200
250
RT162250
300
RT162300
315
RT162315
355
RT162355
315
160
RT162400 RT16-3
850
RT163355
400
RT163400
450
RT163450
500
RT163500
630
RT163630
Material
Weight(g)
Reference
Ceramic
200
RT1600ZT
Resin RT16-1
250
Ceramic
RT1600ZS 700
Resin RT16-2
400
Ceramic
630
Ceramic Resin
Delixi Electric
RT161ZT RT161ZS
1150
Resin RT16-3
RT163315
355
Fuse Base Rate current In(A) RT16-00
RT162125
160
400 RT16-3
RT16180
100
250 RT16-2
RT16002
4
160 RT16-1
Reference
RT162ZT RT162ZS
1280
RT163ZT RT163ZS
77
RT18 Fuse Standard: IEC 60269
Function
RT18 fuse provide: Protection of circuits against overload current Protection of circuits against short-circuit current
Description
Technical Data Rate current range:2-63A Rate voltage:380V Rate breaking capacity:100KA
Standard and certification IEC60269 CE
Overall dimensions
Cylindrical Fuse Type
Size
L
RT18-32
10
38
38
RT18-63
14
51
51 +0.6 -1.0
C 0.6
Hmax
10.3
0.1
10.5
14.3
0.1
13.8
Holder of fuse
78
Type
A
B
C
D
E
F
G
RT18-32
63
60
79
35
80
18
54
RT18-63
78
76
103
35
110
25
75
Delixi Electric
RT18 Fuse Standard: IEC 60269
Cylindrical Fuse
Rate current In(A)
Weight(g)
Reference
RT18-32
2
8
RT10382
4
RT10384
6
RT10386
8
RT10388
10
RT103810
12
RT103812
16
RT103816
20
RT103820
25
RT103825
32
RT103832
2
RT18-63
RT14512
20
4
RT14514
6
RT14516
8
RT14518
10
RT145110
12
RT145112
16
RT145116
20
RT145120
25
RT145125
32
RT145132
40
RT145140
50
RT145150
63
RT145163
Holder of fuse Pole Rate current In(A) Note
Weight(g) Reference
RT18-32X
82
1P
32
Material:Resin Pilotlamp
2P
RT1832Z2XB RT1832Z3XB
3P RT18-32
1P
32
Material:Resin
82
Not Pilotlamp
2P 1P
RT1832Z3B 32
Material:Nylon
82
RT1832Z3X
3P 1P
32
Material:Nylon
82
Not Pilotlamp
2P 1P
RT1832Z3 63
Material:Resin
206
RT1863Z3XB
3P 1P 2P 3P
Delixi Electric
RT1863ZXB RT1863Z2XB
Not Pilotlamp
2P RT18-63
RT1832Z RT1832Z2
3P RT18-63X
RT1832ZX RT1832Z2X
Pilotlamp
2P RT18-32
RT1832ZB RT1832Z2B
3P RT18-32X
RT1832ZXB
63
Material:Resin Pilotlamp
206
RT1863ZB RT1863Z2B RT1863Z3B
79
JXF Power Distribution Box Standard: IEC 670.1989, IEC 60439-1
Function
JXF power distribution box provide: Control,monitoring,measurement and protection for the electric power lines and the main power control equipment
Description
Technical Data Rated operating voltage:220V,380V Rated insulated voltage:400V,660V Rated operating current:400A Protection rating:IP30 for complete set,IP43 for box Instantaneous withstand current:6KA,15KA
Standard and certification IE670.1989,IEC60439-1
Overall dimensions
cover plate
sealing strip
sealing strip
handle lock door peg board
80
box
hinge
Delixi Electric
JXF Power Distribution Box Standard: IEC 670.1989, IEC 60439-1
Delixi Electric
Dimension Istallation dimension D H1 B1
Type
Thickness of iron Figure charge dimension H W
JXF-2520/14
1.0
250 200 140 290 150 170 158 1
JXF252014
JXF-3025/14
1.0
300 250 140 340 200 220 208 1
JXF302514
JXF-3025/18
1.0
300 250 180 340 200 220 208 1
JXF302518
JXF-3030/14
1.0
300 300 140 340 250 220 258 1
JXF303014
JXF-3030/18
1.0
300 300 180 340 250 220 258 1
JXF303018
JXF-4030/14
1.0
400 300 140 440 250 320 258 1
JXF403014
JXF-4030/20
1.0
400 300 200 440 250 320 258 1
JXF403020
JXF-5040/14
1.0
500 400 140 540 350 420 358 1
JXF504014
JXF-5040/20
1.0
500 400 200 540 350 420 358 2
JXF504020
JXF-5040/25
1.0
500 400 250 540 350 420 358 2
JXF504025
JXF-6040/14
1.2
600 400 140 640 350 520 358 2
JXF604014
JXF-6040/20
1.2
600 400 200 640 350 520 358 2
JXF604020
JXF-6040/25
1.2
600 400 250 640 350 520 358 2
JXF604025
JXF-6050/14
1.2
600 500 140 640 450 520 458 2
JXF605014
JXF-6050/20
1.2
600 500 200 640 450 520 458 2
JXF605020
JXF-6050/25
1.2
600 500 250 640 450 520 458 2
JXF605025
JXF-7050/16
1.2
700 500 160 740 450 620 458 2
JXF705016
JXF-7050/20
1.2
700 500 200 740 450 620 458 2
JXF705020
JXF-7050/25
1.2
700 500 250 740 450 620 458 2
JXF705025
JXF-8060/20
1.5
800 600 200 840 550 720 558 2
JXF806020
JXF-8060/25
1.5
800 600 250 840 550 720 558 2
JXF806025
JXF-10080/20 1.5
1000 800 200 1040 750 920 758 2
JXF1008020
JXF-10080/25 1.5
1000 800 250 1040 750 920 758 2
JXF1008025
JXF-10080/30 1.5
1000 800 300 1040 750 920 758 2
JXF1008030
Botoom Number Reference board of lock H6 B6
81
LD11 Series of indicator light Standard: IEC 60947-5-1
Function
LD11 Series of indicator light provide: Pilot signal, anticipating signals Emergency signals and other instructions incidents signal use
Description
Technical data Rated voltage(V) Rated current(mA) Working life(H) Brightness of light(cd/m2) Power frequency withstand voltage Degree of protection
AC/DC 6 12 24 36 48 110 220 50 30000 40 2500V AC 1min IP65
AC 220 380 20
Standard and certification IEC 60947-5-1 CE
82
Delixi Electric
LD11 Series of indicator light Standard: IEC 60947-5-1
Button colour
Rated voltage
Reference
AC.DC 6V
LD1122A21T7
Overall dimensions
Unit:mm
LD1122A21T3 LD1122A21T4 LD1122A21T5 LD1122A21T8 AC.DC 12V
LD1122A21J7 LD1122A21J3 LD1122A21J4 LD1122A21J5 LD1122A21J8
AC.DC 24V
LD1122A21B7 LD1122A21B3 LD1122A21B4 LD1122A21B5 LD1122A21B8
AC.DC 110V
LD1122A21F7 LD1122A21F3 LD1122A21F4 LD1122A21F5 LD1122A21F8
AC.DC 220V
LD1122A21M7 LD1122A21M3 LD1122A21M4 LD1122A21M5 LD1122A21M8
AC 220V
LD1122A41M7 LD1122A41M3 LD1122A41M4 LD1122A41M5 LD1122A41M8
AC 380V
LD1122A41Q7 LD1122A41Q3 LD1122A41Q4 LD1122A41Q5 LD1122A41Q8
AC.DC 6V
LD1122B21T7 LD1122B21T3 LD1122B21T4 LD1122B21T5 LD1122B21T8
AC.DC 12V
LD1122B21J7 LD1122B21J3 LD1122B21J4 LD1122B21J5 LD1122B21J8
AC.DC 24V
LD1122B21B7 LD1122B21B3 LD1122B21B4
Delixi Electric
83
LD11 Series of indicator light Standard: IEC 60947-5-1
Button colour
Rated voltage
Reference
AC.DC 24V
LD1122B21B5
Overall dimensions
Unit:mm
LD1122B21B8 AC.DC 110V
LD1122B21F7 LD1122B21F3 LD1122B21F4 LD1122B21F5 LD1122B21F8
AC.DC 220V
LD1122B21M7 LD1122B21M3 LD1122B21M4 LD1122B21M5 LD1122B21M8
AC 220V
LD1122B41M7 LD1122B41M3 LD1122B41M4 LD1122B41M5 LD1122B41M8
AC 380V
LD1122B41Q7 LD1122B41Q3 LD1122B41Q4 LD1122B41Q5 LD1122B41Q8
AC.DC 6V
LD1122C21T7 LD1122C21T3 LD1122C21T4 LD1122C21T5 LD1122C21T8
AC.DC 12V
LD1122C21J7 LD1122C21J3 LD1122C21J4 LD1122C21J5 LD1122C21J8
AC.DC 24V
LD1122C21B7 LD1122C21B3 LD1122C21B4 LD1122C21B5 LD1122C21B8
AC 220V
LD1122C41M7 LD1122C41M3 LD1122C41M4 LD1122C41M5 LD1122C41M8
AC 380V
LD1122C41Q7 LD1122C41Q3 LD1122C41Q4 LD1122C41Q5 LD1122C41Q8
84
Delixi Electric
LD11 Series of indicator light Standard: IEC 60947-5-1
Button colour
Rated voltage
Reference
AC.DC 6V
LD1122D21T7
Overall dimensions
Unit:mm
LD1122D21T3 LD1122D21T4 LD1122D21T5 LD1122D21T8 AC.DC 12V
LD1122D21J7 LD1122D21J3 LD1122D21J4 LD1122D21J5 LD1122D21J8
AC.DC 24V
LD1122D21B7 LD1122D21B3 LD1122D21B4 LD1122D21B5 LD1122D21B8
AC 220V
LD1122D41M7 LD1122D41M3 LD1122D41M4 LD1122D41M5 LD1122D41M8
AC 380V
LD1122D41Q7 LD1122D41Q3 LD1122D41Q4 LD1122D41Q5 LD1122D41Q8
Delixi Electric
85
LAY3 Serie of pushbuttons Standard: IEC 60947-5-1
Function
LAY3 Serie of Pushbuttons: Control and signal chain
Description
Technical data Conventional thermal current(A) AC-15 Rated operational voltage(V) Rated operational current(A) DC-13 Rated operational voltage(V) Rated operational current(A) Degree of protection Degree of pollution Type of installation Altitude Ambient air temperature
10 660 1.5 440 0.1 IP55 3
380 2.5 220 0.3
220 4.5 110 0.6
2000m -5 ~+40
Standard and certification IEC 60947-5-1
86
Delixi Electric
LAY3 Serie of pushbuttons Standard: IEC 60947-5-1
Flush Button Button colour
Contact blooks
Note
Reference
1NO+1NC
Momentary
LAY311BN4
1NO+1NC
(Non-illuminated)
LAY311BN3
1NO+1NC
LAY311BN2
1NO+1NC
LAY311BN5
1NO+1NC
LAY311BN6
1NO+1NC
LAY311BN1
Overall dimensions
Unit:mm
LAY3 general
Selector Switche-Short Handle 1NO+1NC
Two-position
LAY311X204
1NO+1NC
Maintained
LAY311X203
1NO+1NC
LAY311X202 LAY3-X/2 Selector Swiches
1NO+1NC
Three-position
LAY311X304
1NO+1NC
Maintained
LAY311X303
1NO+1NC
LAY311X302 LAY3-X/3 Selector Swiches
Emergency Stop Pushbutton 1NO+1NC
Maintained
LAY311ZS14
1NO+1NC
LAY311ZS13
1NC
LAY301ZS14
LAY3-ZS/1 Maintained
Flush Buttons Illuminated 1NO+1NC
Incandescent lamp LAY311D4T
1NO+1NC
AC DC 6V
1NO+1NC 1NO+1NC
LAY311D4T LED AC DC 6V
LAY311D4TL
1NO+1NC
LAY311D3TL
1NO+1NC
LAY311D5TL
1NO+1NC
NEON AC 220V
LAY311D3MN
1NO+1NC
LAY311D5MN NEON AC 380V
LAY3-D Illuminated
LAY311D4MN
1NO+1NC
1NO+1NC
Delixi Electric
LAY311D3T
LAY311D4QN
1NO+1NC
LAY311D3QN
1NO+1NC
LAY311D5QN
87
LAY7 Serie of pushbuttons Standard: IEC 60947-5-1
Function
LAY7 Serie of Pushbuttons: Control and signal chain
Description
Technical data Conventional thermal current(A) AC-15 Rated operational voltage(V) Rated operational current(A) DC-13 Rated operational voltage(V) Rated operational current(A) Degree of protection Degree of pollution Type of installation Altitude Ambient air temperature
10 660 1.1 440 0.25 IP55 3
380 2.0 220 0.5
220 3.3 110 1
2000m -5 ~+40
Standard and certification IEC 60947-5-1 CE
Overall dimensions
Unit:mm
Type
22, A
25,
30 B 1-2 block 50
3-4 block 70
66
86
48
68
Flush Button Momentary
14
Extended Button Momentary
20
Whole protection cover button
20
Flush Buttons Illuminated
22
Mushroom Pushbutton Illuminated
24.5
Mushroom Pushbutton Non-illuminated
24.5
Flush Button Maintained
14
Extended Button Maintained
20
Mushroom Pushbutton Maintained
24.5
Flush Button Maintained Illuminated
22
66
86
Emergency Stop Pushbutton
24.5
48
48
Selector Swiches-Short Handle
26
Selector Swiches-Long Handle
26
Key-operated Selector Swiches
40
Note: long 37mm, wide A 30mm B 42mm, in the table values is max.
88
Delixi Electric
LAY7 Serie of pushbuttons Standard: IEC 60947-5-1
Flush Button Button colour
Contact blooks
Note
Reference
1NO+1NC
Momentary
LAY711BN12
1NO+1NC
(Non-illuminated)
LAY711BN22
1NO+1NC
LAY711BN32
1NO+1NC
LAY711BN42
1NO+1NC
LAY711BN52
1NO+1NC
LAY711BN62
1NO+1NC
Maintained
LAY711BNZS12
1NO+1NC
(Non-illuminated)
LAY711BNZS22
1NO+1NC
LAY711BNZS32
1NO+1NC
LAY711BNZS42
1NO+1NC
LAY711BNZS52
1NO+1NC
LAY711BNZS62
Extended Button 1NO+1NC
Momentary
LAY711GN12
1NO+1NC
(Non-illuminated)
LAY711GN22
1NO+1NC
LAY711GN32
1NO+1NC
LAY711GN42
1NO+1NC
LAY711GN52
1NO+1NC
LAY711GN62
1NO+1NC
Maintained
LAY711GNZS12
1NO+1NC
(Non-illuminated)
LAY711GNZS22
1NO+1NC
LAY711GNZS32
1NO+1NC
LAY711GNZS42
1NO+1NC
LAY711GNZS52
1NO+1NC
LAY711GNZS62
1NO+1NC
LAY711JN12
1NO+1NC
LAY711JN22
1NO+1NC
LAY711JN32
1NO+1NC
LAY711JN42
1NO+1NC
LAY711JN52
1NO+1NC
LAY711JN62
Whole protection cover button
Delixi Electric
89
LAY7 Serie of pushbuttons Standard: IEC 60947-5-1
Selector Switche-Short Handle Button colour
Contact blooks
Note
Reference
1NO+1NC
Two-position Maintained
LAY711X2022
1NO+1NC
LAY711X2032
1NO+1NC
LAY711X2042
1NO+1NC
Three-position Maintained
LAY711X3022
1NO+1NC
LAY711X3032
1NO+1NC
LAY711X3042
2NO
LAY720X3022
2NO
LAY720X3032
2NO
LAY720X3042
1NO+1NC
Two-position Right Momentary
LAY711X2122
1NO+1NC
Three-position Right Momentary
LAY711X3122
1NO+1NC
Three-position Right and left Momentary
LAY711X3322
2NO
Three-position Right and left Momentary
LAY720X3322
1NO+1NC
Two-position Maintained
LAY711XB2022
Selector Switche-Long Handle LAY711XB2032
1NO+1NC
LAY711XB2042
1NO+1NC 1NO+1NC
Three-position Maintained
LAY711XB3022
1NO+1NC
LAY711XB3032
1NO+1NC
LAY711XB3042
2NO
LAY720XB3022
2NO
LAY720XB3032 LAY720XB3042
2NO 1NO+1NC
Two-position Right Momentary
LAY711XB2122
1NO+1NC
Three-position Right Momentary
LAY711XB3122
1NO+1NC
Three-position Right and left Momentary
LAY711XB3322
2NO
Three-position Right and left Momentary
LAY720XB3322
1NO+1NC
Two-position Maintained
LAY711Y2002
1NO+1NC
Three-position Maintained
LAY711Y3002
2NO
Three-position Maintained
LAY720Y3002
1NO+1NC
Two-position Right Momentary
LAY711Y2102
1NO+1NC
Three-position Right Momentary
LAY711Y3102
1NO+1NC
Three-position Right and left Momentary
LAY711Y3302
2NO
Three-position Right and left Momentary
LAY720Y3302
1NO+1NC
Momentary(Non-illuminated)
LAY711M32
Key-operated Selector Swiche
Mushroom Pushbutton LAY711M42
1NO+1NC
LAY701M42
1NC 1NO+1NC
Momentary(illuminated LED 6V)
1NO+1NC
LAY711DM4T2L
1NO+1NC 1NO+1NC
90
LAY711DM3T2L LAY711DM5T2L
Maintained(Non-illuminated)
LAY711MZS32
1NO+1NC
LAY711MZS42
1NC
LAY701MZS42 Delixi Electric
LAY7 Serie of pushbuttons Standard: IEC 60947-5-1
Emergency Stop Pushbutton Button colour
Contact blooks
Note
Reference
1NO+1NC
LAY711ZS32
1NO+1NC
LAY711ZS42
1NO
LAY710ZS42
Flush Buttons Illuminated 1NO+1NC
Momentary LED 6V
LAY711D3T2L
1NO+1NC
LAY711D4T2L
1NO+1NC
LAY711D5T2L
1NO+1NC 1NO+1NC
LAY711D8T2L Momentary LED 24V
LAY711D7B2L
1NO+1NC
LAY711D3B2L
1NO+1NC
LAY711D4B2L
1NO+1NC
LAY711D5B2L
1NO+1NC
LAY711D8B2L
1NO+1NC
Momentary LED 220V
LAY711D7M2L
1NO+1NC
LAY711D3M2L
1NO+1NC
LAY711D4M2L
1NO+1NC
LAY711D5M2L
1NO+1NC 1NO+1NC
LAY711D8M2L Momentary NEON 220V
LAY711D1M2N
1NO+1NC
LAY711D3M2N
1NO+1NC
LAY711D4M2N
1NO+1NC
LAY711D5M2N
1NO+1NC 1NO+1NC
LAY711D6M2N Momentary NEON 380V
LAY711D1Q2N
1NO+1NC
LAY711D3Q2N
1NO+1NC
LAY711D4Q2N
1NO+1NC
LAY711D5Q2N
1NO+1NC 1NO+1NC
LAY711D6Q2N Maintained LED 6V
LAY711DZS7T2L
1NO+1NC
LAY711DZS3T2L
1NO+1NC
LAY711DZS4T2L
1NO+1NC
LAY711DZS5T2L
1NO+1NC
LAY711DZS8T2L
1NO+1NC
Delixi Electric
LAY711D7T2L
1NO+1NC
Maintained LED 24V
LAY711DZS7B2L
1NO+1NC
LAY711DZS3B2L
1NO+1NC
LAY711DZS4B2L
1NO+1NC
LAY711DZS5B2L
1NO+1NC
LAY711DZS8B2L
91
LAY7 Serie of pushbuttons Standard: IEC 60947-5-1
Flush Buttons Illuminated Button colour
Contact blooks
Note
Reference
1NO+1NC
Maintained LED 220V
LAY711DZS7M2L
1NO+1NC
LAY711DZS3M2L
1NO+1NC
LAY711DZS4M2L
1NO+1NC
LAY711DZS5M2L
1NO+1NC 1NO+1NC
LAY711DZS8M2L Maintained NEON 220V
LAY711DZS3M2N
1NO+1NC
LAY711DZS4M2N
1NO+1NC
LAY711DZS5M2N
1NO+1NC 1NO+1NC
92
LAY711DZS1M2N
1NO+1NC
LAY711DZS6M2N Maintained NEON 380V
LAY711DZS1Q2N
1NO+1NC
LAY711DZS3Q2N
1NO+1NC
LAY711DZS4Q2N
1NO+1NC
LAY711DZS5Q2N
1NO+1NC
LAY711DZS6Q2N
Delixi Electric
LAY8 Serie of pushbuttons Standard: IEC 60947-5-1
Function
LAY8 Serie of Pushbuttons: Control and signal chain
Description
Technical data Conventional thermal current(A) AC-15 Rated operational voltage(V) Rated operational current(A) DC-13 Rated operational voltage(V) Rated operational current(A) Degree of protection Degree of pollution Type of installation Altitude Ambient air temperature
10 660 1.5 440 0.2 IP55 3
380 2.5 220 0.4
220 4.5 110 0.8
2000m -5 ~+40
Standard and certification IEC 60947-5-1 CE
Delixi Electric
93
LAY8 Serie of pushbuttons Standard: IEC 60947-5-1
Flush Button Button colour
Contact blooks
Note
Reference
1NO+1NC
Momentary
LAY811BN1
1NO+1NC
(Non-illuminated)
LAY811BN2
1NO+1NC
LAY811BN3
1NO+1NC
LAY811BN4
1NO+1NC
LAY811BN5
1NO+1NC
LAY811BN6
1NO+1NC
Maintained
LAY811ZS1
1NO+1NC
(Non-illuminated)
LAY811ZS2
1NO+1NC
LAY811ZS3
1NO+1NC
LAY811ZS4
1NO+1NC
LAY811ZS5
1NO+1NC
LAY811ZS6
1NO+1NC
Waterproof
LAY811S1
1NO+1NC
(Non-illuminated)
LAY811S2
1NO+1NC
LAY811S3
1NO+1NC
LAY811S4
1NO+1NC
LAY811S5
1NO+1NC
LAY811S6
Overall dimensions
Unit:mm
Selector Switche-Short Handle 1NO+1NC
Two-position Maintained
1NO+1NC
LAY811X203
1NO+1NC 1NO+1NC
LAY811X202 LAY811X204
Three-position Maintained
LAY811X302
1NO+1NC
LAY811X303
1NO+1NC
LAY811X304
2NO
LAY820X302
1NO+1NC
Two-position Right Momentary
LAY811X312
1NO+1NC
Three-position Right Momentary
LAY811X212
2NO
Three-position Right and left Momentary
LAY820X312
Two-position Maintained
LAY811XB202
Selector Switche-Long Handle 1NO+1NC 1NO+1NC
LAY811XB203
1NO+1NC 1NO+1NC
LAY811XB204 Three-position Maintained
LAY811XB303
1NO+1NC
LAY811XB304
2NO
94
LAY811XB302
1NO+1NC
LAY820XB302
1NO+1NC
Momentary(Non-illuminated)
LAY811XB212
1NO+1NC
Three-position Right Momentary
LAY811XB312
2NO
Three-position Right and left Momentary
LAY820XB332
Delixi Electric
LAY8 Serie of pushbuttons Standard: IEC 60947-5-1
Mushroom Pushbutton Button colour
Contact blooks
Note
Reference
1NO+1NC
LAY811M3
1NO+1NC
LAY811M4
Overall dimensions
Unit:mm
Emergency Stop Pushbutton 1NO+1NC
LAY811ZS3
1NO+1NC
LAY811ZS4
1NO
LAY810ZS4
Flush Buttons Illuminated 1NO+1NC
LED AC.DC 6V
LAY811D3T2L
1NO+1NC
LAY811D4T2L
1NO+1NC
LAY811D5T2L
1NO+1NC 1NO+1NC
LAY811D8T2L LED AC.DC 24V
LAY811D7B2L
1NO+1NC
LAY811D3B2L
1NO+1NC
LAY811D4B2L
1NO+1NC
LAY811D5B2L
1NO+1NC 1NO+1NC
LAY811D8B2L LED AC.DC 220V
LAY811D7M2L
1NO+1NC
LAY811D3M2L
1NO+1NC
LAY811D4M2L
1NO+1NC
LAY811D5M2L
1NO+1NC
LAY811D8M2L
1NO+1NC
LED AC 220V
LAY811D7M4L
1NO+1NC
LAY811D3M4L
1NO+1NC
LAY811D4M4L
1NO+1NC
LAY811D5M4L
1NO+1NC 1NO+1NC
Delixi Electric
LAY811D7T2L
1NO+1NC
LAY811D8M4L LED AC 380V
LAY811D7Q4L
1NO+1NC
LAY811D3Q4L
1NO+1NC
LAY811D4Q4L
1NO+1NC
LAY811D5Q4L
1NO+1NC
LAY811D8Q4L
95
72 Series Pannel Meter Standard: IEC 51-1~9
Function
72 series pannel meter provide: Measuring current,voltage Measuring frequency,power,power factor
Description Pressure test Voltage:2000V Frequency:50Hz Duration:1min
Tolerance mechanical impact:max 147m/s2 Response time: 4s Pointer deflection angle:90
Standard and certification IEC 51-1~9 CE
Overall dimensions Unit:mm
96
Delixi Electric
72 Series Pannel Meter Standard: IEC 51-1~9
Ordering information Type
Accuracy Specification rating
Note
Shape(mm)
Ammeter
1.5
30/5A
AC Type
72
72
67.5
72TA30
40/5A
External connection 72
72
67.5
72TA40
50/5A
transformer
72
72
67.5
72TA50
60/5A
2 times of current
72
72
67.5
72TA60
75/5A
overload
72
72
67.5
72TA75
80/5A
72
72
67.5
72TA80
100/5A
72
72
67.5
72TA100
150/5A
72
72
67.5
72TA150
160/5A
72
72
67.5
72TA160
200/5A
72
72
67.5
72TA200
250/5A
72
72
67.5
72TA250
300/5A
72
72
67.5
72TA300
400/5A
72
72
67.5
72TA400
600/5A
72
72
67.5
72TA600
800/5A
72
72
67.5
72TA800
1000/5A
72
72
67.5
72TA1000
1600/5A
72
72
67.5
72TA1600
5000/5A
72
72
67.5
72TA5000
10000/5A
72
72
67.5
72TA10000
72
72
67.5
72TA5A
5A
AC Type
Reference
Direct connection 2.5
15A
AC Type
72
72
67.5
72TA15A
20A
Direct connection
72
72
67.5
72TA20A
25A
2 times of current
72
72
67.5
72TA25A
30A
overload
72
72
67.5
72TA30A
40A
72
72
67.5
72TA40A
50A
72
72
67.5
72TA50A
60A
72
72
67.5
72TA60A
80A
72
72
67.5
72TA80A
72
72
67.5
72TA100A
1.5
5A
DC Type
72
72
67.5
72C1A5A
1.5
300V
AC Type
72
72
67.5
72TV300
72
72
67.5
72TV500
100A Voltmerer
500V
72
72
67.5
72TV600
500V
DC Type
72
72
67.5
72C1V500
45-55HZ (200V)
AC Type
72
72
67.5
72TZ200
600V Frequency meter
1.0
9
Delixi Electric
97
96 Series Pannel Meter Standard: IEC 51-1~9
Function
96 series pannel meter provide: Measuring current,voltage Measuring frequency,power,power factor
Description Pressure test Voltage:2000V Frequency:50Hz Duration:1min
Tolerance mechanical impact:max 147m/s2 Response time: 4s Pointer deflection angle:90
Standard and certification IEC 51-1~9 CE
Overall dimensions Unit:mm
98
Delixi Electric
96 Series Pannel Meter Standard: IEC 51-1~9
Ordering information Type
Accuracy Specification rating
Note
Shape(mm)
Ammeter
1.5
30/5A
AC Type
96
96
67.5 96TA30
40/5A
External connection 96 transformer 96
96
67.5 96TA40
50/5A
96
67.5 96TA50
60/5A
96
96
67.5 96TA60
75/5A
96
96
67.5 96TA75
80/5A
96
96
67.5 96TA80
100/5A
96
96
67.5 96TA100
150/5A
96
96
67.5 96TA150
160/5A
96
96
67.5 96TA160
200/5A
96
96
67.5 96TA200
250/5A
96
96
67.5 96TA250
300/5A
96
96
67.5 96TA300
400/5A
96
96
67.5 96TA400
600/5A
96
96
67.5 96TA600
800/5A
96
96
67.5 96TA800
1000/5A
96
96
67.5 96TA1000
1600/5A
96
96
67.5 96TA1600
5000/5A
96
96
67.5 96TA5000
10000/5A
96
96
67.5 96TA10000
96
96
67.5 96TA5A
5A
AC Type
Reference
Direct connection 2.5
15A
AC Type
96
96
67.5 96TA15A
20A
Direct connection
96
96
67.5 96TA20A
25A
96
96
67.5 96TA25A
30A
96
96
67.5 96TA30A
40A
96
96
67.5 96TA40A
50A
96
96
67.5 96TA50A
60A
96
96
67.5 96TA60A
80A
96
96
67.5 96TA80A
96
96
67.5 96TA100A
1.5
5A
DC Type
96
96
67.5 96C1A5A
1.5
300V
AC Type
96
96
67.5 96TV300
96
96
67.5 96TV500
100A Voltmerer
500V
96
96
67.5 96TV600
500V
DC Type
96
96
67.5 96C1V500
45-55HZ (200V)
AC Type
96
96
67.5 96TZ200
600V Frequency meter
Delixi Electric
1.0
99
TND Voltage Stabilizer
Function
TND voltage stabilizer provide: Control system consist of linear integrated circuit automaticly control voltage regulation Timelag, overvoltage and undervoltage protection
Description
Technical Data Type
TND0.5kVA~5kVA Voltage regulation accuracy
Output voltage Undervoltage protection Overvoltage protection
220
4%,110
4%
TND7kVA~30kVA 220
4%
184V 4V(set up according to the customers request) 246V
4V
Phase
single-phase
Input voltage range
160V~240V
Efficiency
>90%
Voltage regulation speed
<1s(when input voltage change 10%)
Temperature rise
<60
Frequency
50Hz/60Hz
Enviroment temperature,relative temperature Waveform distortion
-50
(full range) ~40
below 90%
Rated maximum output current(A)
no additional distortion 2(500VA),4(1000VA),6(1500VA),8(2000VA),12(3000VA), 20(5000VA),25(7000VA),40(10KVA),85(15KVA), 73(20KVA),109(30KVA)
Withstand voltage
1500V/1min
Overall dimensions
unit: mm
Product shape
Model
Wide
Length
Desktop
TND-0.5
190
160
135
TND-1
205
190
155
TND-1.5
205
190
155
TND-2
240
270
200
TND-3
225
305
235
TND-5
225
310
290
TND-7
240
387
360
TND-10
240
387
360
TND-10
310
340
535
TND-15
340
360
640
TND-20
340
380
780
TND30
425
390
845
Cabinet type
100
Hight
Delixi Electric
TND Voltage Stabilizer
Ordering information Product shape Desktop
Cabinet type
Delixi Electric
Power rating
Referencce
0.5K
TNDP5
1K
TND1
1.5K
TND1P5
2K
TND2
3K
TND3
5K
TND5
7K
TND7
10K
TND10
10K
TND10G
15K
TND15G
20K
TND20G
30K
TND30G
101
Nylon Cable Ties Series
Description
Technical Data Material:
Color:
Using nylon 66 material that recognized by UL Fire-protection rating:94V-2 Acid and erosion control,insulate well and difficult to aging White, black and other colors
Overall dimensions Long INCH
102
MM
MAX.Bundle Tensile Strength Packing Width DIA(mm) (root) LBS KGS
Reference
2.4"
60
2.5
2-11
18
8
100
DAR205060**
3.2"
80
2.5
2-16
18
8
100
DAR205080**
4"
100
2.5
2-22
18
8
100
DAR205100**
4.7"
120
2.5
2-30
18
8
100
DAR205120**
6" 12"
150 200
2.5 2.5
2-35 3-80
18 18
8 8
100 100
DAR205150** DAR205200**
4.7"
120
3.6
2-30
40
18
100
DAR306120**
6"
150
3.6
2-35
40
18
100
DAR306150**
7.1"
180
3.6
3-42
40
18
100
DAR306180**
8"
200
3.6
3-50
40
18
100
DAR306200**
10" 12"
250 300
3.6 3.6
3-65 3-80
40 40
18 18
100 100
DAR306250** DAR306300**
14.6"
370
3.6
3-80
40
18
100
DAR306370**
7.1"
180
4.8
3-42
50
22
100
DAR408180**
8"
200
4.8
3-50
50
22
100
DAR408200**
10"
250
4.8
3-65
50
22
100
DAR408250**
12" 14"
300 350
4.8 4.8
3-80 3-90
50 50
22 22
100 100
DAR408300** DAR408350**
15"
380
4.8
3-102
50
22
100
DAR408380**
16"
400
4.8
3-105
50
22
100
DAR408400**
17.7"
450
4.8
3-130
50
22
100
DAR408450**
19.7"
500
4.8
3-150
50
22
100
DAR408500**
8" 10"
200 250
7.2 7.2
3-50 3-65
120 120
55 55
100 100
DAR702200** DAR702250**
12"
300
7.2
4-80
120
55
100
DAR702300**
14"
350
7.2
4-90
120
55
100
DAR702350**
16"
400
7.2
4-105
120
55
100
DAR702400**
20"
500
7.2
4-150
120
55
100
DAR702500**
30" 18"
750 450
7.2 9
10-220 8-118
120 175
55 80
100 100
DAR702750** DAR900450**
20"
500
9
8-150
175
80
100
DAR900500**
21.6"
550
9
8-160
175
80
100
DAR900550**
27.5"
700
9
10-205
175
80
100
DAR900700**
32"
800
9
10-230
175
80
100
DAR900800**
2.4" 3.2"
60 80
2.2 2.2
2-11 2-16
18 18
8 8
100 100
DAR202060** DAR202080**
4"
100
2.2
2-22
18
8
100
DAR202100**
4.7"
120
2.2
2-30
18
8
100
DAR202120**
6"
150
2.2
2-35
18
8
100
DAR202150**
8"
200
2.2
3-50
18
8
100
DAR202200**
4.7" 6"
120 150
3.2 3.2
3-30 3-35
40 40
18 18
100 100
DAR302120** DAR302150**
Delixi Electric
Nylon Cable Ties Series
Long INCH
Normal Packing
Hang tag Packing
Delixi Electric
MM
Width
MAX.Bundle Tensile Strength Packing Reference (root) DIA(mm) LBS KGS
7"
180
3.2
3-42
40
18
100
DAR302180
8"
200
3.2
3-50
40
18
100
DAR302200
10"
250
3.2
3-65
40
18
100
DAR302250
12"
300
3.2
3-80
40
18
100
DAR302300
14"
350
3.2
3-90
40
18
100
DAR302350
4.7"
120
4.2
3-30
50
22
100
DAR402120
6"
150
4.2
3-35
50
22
100
DAR402150
7.1"
180
4.2
3-42
50
22
100
DAR402180
8"
200
4.2
3-50
50
22
100
DAR402200
10"
250
4.2
3-65
50
22
100
DAR402250
12"
300
4.2
3-80
50
22
100
DAR402300
14"
350
4.2
3-90
50
22
100
DAR402350
16"
400
4.2
3-105
50
22
100
DAR402400
8"
200
6.5
3-50
120
55
100
DAR605200
10"
250
6.5
3-65
120
55
100
DAR605250
12"
300
6.5
4-80
120
55
100
DAR605300
14"
350
6.5
4-90
120
55
100
DAR605350
16"
400
6.5
4-105
120
55
100
DAR605400
17.7"
450
6.5
3-130
120
55
100
DAR605450
19.7"
500
6.5
4-150
120
55
100
DAR605500
21.6"
550
6.5
4-165
120
55
100
DAR605550
24"
600
6.5
4-170
120
55
100
DAR605600
Note:"
" express color and packing code
Color
Black
White
Blue
Red
Yellow
Green
Normal Packing
BB
WB
UB
RB
YB
GB
Hang tag Packing
BL
WL
UL
RL
YL
GL
103
Power Distribution and Industry Control Product
CDW7
CDM1
JXF CDC17
CDM1
CDM1L
CDPZ50
CDB6a
Building
CDR17
CDY1
LAY3
DDS607
CDB6LE
Industry
LMK
Energy
Residential
72
DELIXI ELECTRIC LTD. ADD: DELIXI LIUSHI INDUSTRIAL PARK, YUEQING, ZHEJIANG, P.R.CHINA POST CODE: 325604 Http: //www.delixi-electric.com