JOONGWON OPEN CUTOUTS Type SQ OUTDOOR Distribution(14.4kV through 38kV)


OPEN CUTOUTS Type SQ OUTDOOR Distribution(14.4kV through 38kV) âœ˝Porcelain Insulator Type â– Construction Parallel-groove connector

tin plated cast brass. For ease of conductor connection, accommodates two conductors of unlike size in a single connector. Other styles of connectors are also available.

Recoil bar

heavy galvanized steel(which is also used for inserts. hangers. structural bolts and nuts)

Upper Contacts silver-to -silver at both surfaces

Bridproof-design porcelain insulator higher insulation characteristics than IEEE distribution - CutOut

Backup spring

stainless steel. Contact pressure not dependent on current carrying parts

Attachment hooks

for Loadbuster, Heavy construction also serves to guide tube during closing

Lower contacts(not visible)

tsilver-to-silver, provide dual current path, in dependent of hinge pivot. Stainless-steel back up sprin gs prevent arcing when tube rises in hinge during recoil

Fuse tube

fiber-lined epoxy fiber glass liner that's virtually impervious to water ingress. Special UV-resistant finish assures long life.

Sturdy ferrules

pinned to top and bottom of tube for permanent alignment, Large, accessible lifting ring

Toggle joint

Trunnion pocket

assures reliable dropout after operation.

seures tube in hinge during closing

Flipper Trunnion casting

surfaces around trunnion bear on broad hinge surfaces to keep tube in alignment during closing

2

JOONGWON ELECTRIC CORPORATION

Hinge

Basic material is stainless. But upon user's request, can be replace bronze casting.

gives high-speed terminal separation. quick cable flip-out, and (in conjunction with the toggle joint) reduces transmission of forces to fuse link during closing


✽Porcelain Insulator Type ■ Performance 60-Hertz Short-Circuit Interrupting Ratings① ─ Per IEEE C37.41-2008 OVERHEAD-POLE-TOP STYLES-Both Three-Phase and Single-Phase Application② System Voltage, kV

Continuous Rating

Style

Voltage Rating/kV, Nom 

Short-Circuit Interrupting Rating, Ampere, RMS, Asymmetrical③ and Symmertrical④ (One-Shot rating, where applicable, shown in parentheses) 200 Amperes

100 Amperes ⑥

U

E

14.4

14.4

20

25.8

25

25

U⑥ 25

25

27/34.5 27/34.5

25

25

Voltage Rating/kV, Max

15

15

24

27

27

27

27

27

38

38

27

27

Voltage Rating/kV, BIL

95

95

125

125

125

125

150

150

150+

200

125

150

Frequency, ㎐

60

60

50

Leakage distance to

80420

80443

10000

16000

ground, minimum, Inches ★ Catalog number

17 (430mm)

11

80442G 80442H -

(12000)*

60

60

10000

11

13

19

26

80442

80442T 80442S 80445H

12000

12000

12000

80445TR 80445 05/08/10 80432

1

80432S

(12000)* (16000)* (16000)* (16000)* (16000)* -

7100

11

12000

4.16 thru 15 10600

(8000)* Short-Circuit interrupting current

26▲ 39/52/65

7200 (8000)*

7100

8000

8000

8000

-

-

-

8000

8000

5600

5600

-

-

8000

(8000)* (10600)* (10600)* (10600)* (10600)* 10000

12000

12000

12000

12000

(12000)* (16000)* (16000)* (16000)* (16000)* 15● thru 27●

-

-

7200 (8000)*

7100

8000

8000

8000

(8000)* (10600)* (10600)* (10600)* (10600)* 12000

27▲ thru 38▲

-

-

-

-

8000

-

-

-

-

12000

8000

8000

① Consult the nearest JOONGWON Sales Office for 50-hertz ratings. ② Asymmetrical and symmetrical ratings are given for each catalog number in each applicable system-voltage range. In each case, the asymmetrical rating is given first(in bold-face type) and symmetrical rating is given second(in light-face type). Rating in parentheses are the associated one-short rating(see Note *) ③ Nominal asymmetrical rating are based on total available short-circuit current of the circuit including the DC component, in accordance with IEEE standards. ④ Symmetrical rating assigned are based on available symmetrical short-circuit current at locations where X/R ratio is equal to 8 (for Cutout Catalog number 80420) or 12 (for all other overhead─pole-top style cutouts). IEEE C37.41-2000 specifies these X/R ratios, as applicable, depending on cutout voltage rating and interrupting current rating. ⑤ Uses either nonremovable or removable buttonhead fuse links. ⑥ Uses removable buttonhead fuse links only. ⑦ E - Extra heavy duty, U - Ultra heavy duty, H - Heavy duty. ● Applicable for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connected capacitor banks in solidly-grounded-neutral (multigrounded-neutral) systems─where the leakage distance to ground meets user’s requirements. ✽ One-shot rating, based on replacement of cutout tube only. ▲ Applicable for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connected capacitor banks in solidly-grounded-neutral (multigrounded-neutral) systems. + Meets 170-kV BIL rating requirement of IEC Publication 60282-2.

www.joongwon.co.kr

3


OPEN CUTOUTS Type SQ OUTDOOR Distribution(14.4kV through 38kV) ✽Porcelain Insulator Type ■ Production series

4

JOONGWON ELECTRIC CORPORATION

80445

80445H

80442G

80442

80442

80443


âœ˝Composite - Polymer Silicone Insulator Type â– Construction

Parallel-groove connector

tin plated cast brass. For ease of conductor connection, accommodates two conductors of unlike size in a single connector. Other styles of connectors are also available.

Composite-polymer silicone insulator 30~50% lighter than porcelain, highly break resistant, provides better performance in coastal and highpollution areas.

Recoil bar

heavy galvanized steel(which is also used for inserts. hangers. structural bolts and nuts)

Backup spring Upper Contacts silver-to -silver at both surfaces

stainless steel. Contact pressure not dependent on current carrying parts

Silicone Insulation Cover - Option

Attachment hooks for Loadbuster, Heavy construction also serves to guide tube during closing

Toggle joint

assures reliable dropout after operation.

Fuse tube

fiber-lined epoxy fiber glass liner that's virtually impervious to water ingress. Special UV-resistant finish assures long life.

Sturdy ferrules

pinned to top and bottom of tube for permanent alignment, Large, accessible lifting ring

Hinge

Basic material is stainless. But upon user's request, can be replace bronze casting.

Lower contacts(not visible)

tsilver-to-silver, provide dual current path, in dependent of hinge pivot. Stainless-steel back up sprin gs prevent arcing when tube rises in hinge during recoil

Trunnion pocket

seures tube in hinge during closing

Trunnion casting

surfaces around trunnion bear on broad hinge surfaces to keep tube in alignment during closing

Flipper

gives high-speed terminal separation. quick cable flip-out, and (in conjunction with the toggle joint) reduces transmission of forces to fuse link during closing

www.joongwon.co.kr

5


OPEN CUTOUTS Type SQ OUTDOOR Distribution(14.4kV through 38kV) ✽Composite - Polymer Silicone Insulator Type ■ Performance 60-Hertz Short-Circuit Interrupting Ratings① - Per IEEE C37.41-2008 OVERHEAD-POLE-TOP STYLES-Both Three-Phase and Single-Phase Application② System Voltage, kV

Continuous Rating

Style

Short-Circuit Interrupting Rating, Ampere, RMS, Asymmetrical③ and Symmertrical④ (One-Shot rating, where applicable, shown in parentheses) 100 Amperes

U⑥

Voltage Rating/kV, Nom 

20

25.8

25.8

25

27/38

Voltage Rating/kV, Max

24

27

27

27

38

Voltage Rating/kV, BIL

125

125

125

150

170

Frequency, ㎐

50

Leakage distance to

ground, minimum,mm

Catalog number

60

570

600

600

660

685

80445PG

80442PH

80442P

80445PH

80445P

-

10000

12000

12000

(12000)*

(16000)*

(16000)*

-

4.16 thru 15

Short-Circuit interrupting current

7200

7100

8000

8000

(8000)*

(8000)*

(10600)*

(10600)*

-

10000

12000

12000

(12000)*

(16000)*

(16000)*

7200

7100

8000

8000

(8000)*

(8000)*

(10600)*

(10600)*

15● thru 27●

-

12000 27▲ thru 38▲

-

-

-

8000

① Consult the nearest JOONGWON Sales Office for 50-hertz ratings. ② Asymmetrical and symmetrical ratings are given for each catalog number in each applicable system-voltage range. In each case, the asymmetrical rating is given first(in bold-face type) and symmetrical rating is given second(in light-face type). Rating in parentheses are the associated one-short rating(see Note *) ③ Nominal asymmetrical rating are based on total available short-circuit current of the circuit including the DC component, in accordance with IEEE standards. ④ Symmetrical rating assigned are based on available symmetrical short-circuit current at locations where X/R ratio is equal to 12 for all other overhead─pole-top style cutouts. IEEE C37.41-2000 specifies these X/R ratios, as applicable, depending on cutout voltage rating and interrupting current rating. ⑤ Uses either nonremovable or removable buttonhead fuse links. ⑥ Uses removable buttonhead fuse links only. ⑦ E - Extra heavy duty, U - Ultra heavy duty, H - Heavy duty. ● Applicable for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connected capacitor banks in solidly-groundedneutral (multigrounded-neutral) systems─where the leakage distance to ground meets user’s requirements. ✽ One-shot rating, based on replacement of cutout tube only. ▲ Applicable for protection of single-phase-to-neutral circuits (lines or transformers) only, and grounded-wye connected capacitor banks in solidly-groundedneutral (multigrounded-neutral) systems.

6

JOONGWON ELECTRIC CORPORATION


✽Composite - Polymer Silicone Insulator Type ■ Production series

80445P

80442PH

80445PH

80442P

80445PG

Example : Installation of insulation cover

www.joongwon.co.kr

7


J & W PRODUCTS ■ Switches

•Fuse Cut Out Switch(14.4㎸ ~ 38㎸) •25.8kV Pole Mounted SF6 Gas Insulated Load Break Switch (Automatic-630/400A, Manual-400A) •25.8㎸ SF6 Gas Insulated Load Break Switch For Underground (600A, 4W/4S-Automatic/Manual, 3W/3S-Manual) •25.8kV Auto Section Switch (200A, Automatic/Manual) •25.8kV Auto Section Switch (Indoor type) (200A, Automatic/Manual) •25.8kV Interrupter Switch (Single/Double) •24kV Load Break Switch (Indoor type) •25.8kV Disconnecting Switch

•25.8kV Fuse Link (1~100K) •Wire Fuse (38A, 50A) •Current Limiting Fuse for the protection of semiconductor devices •24kV High Voltage Current Limiting Fuse •15.5kV Current Limiting Fuse •7.2kV Medium Voltage Current Limiting Fuse (1~100A) •Current Limiting Fuse Holder (7.2/24kV) ■ Absorbers / Arresters

•Surge Arrester (4, 5, 9, 18kV-5kA) •Polymer Lightning Arrester (6, 12, 18kV-5kA) •Polymer Surge Absorber (3.6, 7.2, 18kV) ■ Metering Out Fit

■ Breakers

•7.2kV 8kA Vacuum Circuit Breaker (400A) •7.2kV 12.5kA Vacuum Circuit Breaker (630A) •7.2kV 20kA Vacuum Circuit Breaker (630/1250A) •7.2kV 31.5kA Vacuum Circuit Breaker (630/1250/2000A) •15kV 25kA Vacuum Circuit Breaker (630/1250A) •24kV 12.5kA Vacuum Circuit Breaker (630/1250A) •24kV 25kA Vacuum Circuit Breaker (630/1250/2000A) •7.2/12/24kV 12.5kA Vacuum Circuit Breaker (630A) - Magnetic Actuator type •25.8kV 25kA MCSG Vacuum Circuit Breaker (630/1250A)

•25.8kV Metering Out Fit (5/5A~400/5A) •25.8kV PT (25~200VA) •25.8kV GPT (25/50~100/200VA) ■ Indicators

•Faulted Circuit Indicator ■ Conductive Concrete

•Earthing Products ■ Photo Etching

■ Fuses

•25.8kV Power Fuse (Outdoor type) (1~200K) •25.8kV Power Fuse (Indoor type) (1~200K, 300E, 400E) •25.8kV Power Fuse Unit (1~200K)

JOONGWON ELECTRIC CORPORATION 727-9, Wonsi-dong, Danwon-gu, Ansan-si, Gyeonggi-do, Korea Tel : 82-31-492-6863〜4 / 82-31-492-6866(DIR.) Fax : 82-31-492-2620 http//www.joongwon.co.kr E-mail : joongwon@joongwon.co.kr