DELL EMC DES-1121 CERTIFICATION EXAM QUESTIONS AND ANSWERS PDF
DellEMCDES 1121Exam
EDUSUM.COM
GetcompletedetailonDES 1121examguidetocrackDellEMCPowerMaxandVMAXFamily SolutionsSpecialistforImplementationEngineers.YoucancollectallinformationonDES-1121 tutorial,practicetest,books,studymaterial,examquestions,andsyllabus.Firmyourknowledgeon DellEMCPowerMaxandVMAXFamilySolutionsSpecialistforImplementationEngineersandget readytocrackDES 1121certification.ExploreallinformationonDES 1121examwithnumberof questions,passingpercentageandtimedurationtocompletetest.
Introduction to Dell EMC Certified Specialist - Implementation Engineer - PowerMax and VMAX Family Solutions (DCS-IE) Exam
The Dell EMC DES 1121 Exam is challenging and thorough preparation is essential for success. This exam study guide is designed to help you prepare for the PowerMax and VMAX Family Solutions Specialist certification exam. It contains a detailed list of the topics covered on the Professional exam, as well as a detailed list of preparation resources. This study guide for the Dell EMC PowerMax and VMAX Family Solutions Specialist for Implementation Engineers will help guide you through the study process for your certification.
WWW.EDUSUM.COM PDF DES 1121: Dell EMC PowerMax and VMAX Family Solutions Specialist for 1 Implementation Engineers
Dell EMC PowerMax and VMAX Family
Specialist for Implementation Engineers Exam Summary
Name:
EMC
for PowerMax
Administration
and VMAX Family Local Replication Concepts
and VMAX Family Remote Replication Concepts (ES132STG00368)
Disruptive Migration to PowerMax and VMAX Family (ES132STG00364)
and VMAX Family Configuration and Business Continuity Administration
Exam:
EMC PowerMax
EMC
VMAX Family Solutions
Practice
WWW.EDUSUM.COM PDF DES 1121: Dell EMC PowerMax and VMAX Family Solutions Specialist for 2 Implementation Engineers DES-1121
Solutions
● Exam
Dell
PowerMax and VMAX Family Solutions Specialist for Implementation Engineers ● Exam Code: DES-1121 ● Exam Price: $230 (USD) ● Duration: 90 mins ● Number of Questions: 60 ● Passing Score: 63% ● Books / Training: ○ PowerMax Concepts and Features (ES131STG00363) ○ Solutions Enabler Implementation (ES132STG00365) ○ Unisphere
Implementation and
(ES132STG00366) ○ PowerMax
(ES132STG00367) ○ PowerMax
○ Non
○ PowerMax
(ES122STG00644) ● Schedule
Pearson VUE ● Sample Questions: Dell
and
Specialist Sample Questions ● Recommended Practice: Dell
DES-1121 Certification
Exam
Exam Syllabus: DES-1121 Dell EMC Certified
Implementation Engineer
PowerMax and VMAX Family Solutions (DCS-IE)
Topic Details Weights
PowerMax and VMAX Family Local and Remote Replication
- Describe TimeFinder SnapVX architecture, features, capabilities, benefits, and management - Describe SRDF architecture, features, capabilities, benefits, and management
Describe Open Replicator architecture, features, capabilities, benefits, and management
9%
PowerMax and VMAX Family Business Continuity Administration
Describe how TimeFinder SnapVX operations with SYMCLI and Unisphere for PowerMax in physical and virtual environments are performed - Describe how SRDF operations with SYMCLI and Unisphere for PowerMax in physical and virtual environments are performed
26%
Unisphere for PowerMax Implementation and Administration
- Explain Unisphere for PowerMax functionality, architecture, and how administration tasks are performed
Describe how Unisphere for PowerMax is installed and how to navigate the Unisphere for PowerMax user interface
Explain how PowerMax and VMAX Family arrays are configured and storage is provisioned
Describe virtual provisioning, service levels, and VMAX3 FAST concepts
8%
PowerMax and VMAX Family Configuration Administration
Identify and describe PowerMax and VMAX Family device creation and port management - Explain how storage is allocated using autoprovisioning groups and how SL based provisioning with Unisphere for PowerMax and SYMCLI is performed
Identify and describe how Storage Resource Pools, Storage Group compliance, and Compression are monitored - Explain how Workload Planning with Unisphere for PowerMax is performed - Explain storage management in a virtualized environment for PowerMax and VMAX Family arrays
41%
DES 1121: Dell EMC PowerMax and VMAX Family Solutions Specialist for 3 Implementation Engineers
WWW.EDUSUM.COM PDF
Specialist -
-
Topic Details Weights
Solutions Enabler Implementation
Describe the functions of commonly used Solutions Enabler daemons, Solutions Enabler Virtual Appliance usage, and how Solutions Enabler is installed
- Explain Gatekeeper management, option files usage, and environment variables
- Describe Non-Disruptive Migrations to PowerMax and VMAX Family arrays
Non-Disruptive Migration to PowerMax and VMAX Family
Identify and describe how Non Disruptive Migrations using Unisphere for PowerMax and Non Disruptive Migrations using SYMCLI are performed
Dell EMC DES-1121 Certification Sample Questions and Answers
7%
9%
To make you familiar with Dell EMC PowerMax and VMAX Family Solutions Specialist for Implementation Engineers (DES-1121) certification exam structure, we have prepared this sample question set. We suggest you to try our Sample Questions for DCS-IE DES-1121 Certification to test your understanding of Dell EMC DES-1121 process with the real Dell EMC certification exam environment.
DES-1121 Dell EMC PowerMax and VMAX Family Solutions Specialist for Implementation Engineers Sample Questions:-
01. Which service level manages TimeFinder SnapVX snapshot deltas in a VMAX3 array?
a) Silver service level
b) Service level set on the target Storage Group
c) Optimized service level
d) Service level set on the source Storage Group
02. A systems administrator wants to attach a new IBM server to a PowerMax 8000. The administrator is concerned about the port flag setting and interoperability. Where can the correct port setting be retrieved?
a) Live Optics
DES 1121: Dell EMC PowerMax and VMAX Family Solutions Specialist for 4 Implementation Engineers
WWW.EDUSUM.COM PDF
b) Dell EMC E Lab Navigator c) www.dell.com d) Unisphere Online Help
03. You are performing a non-disruptive migration between two arrays within the same data center. What is the maximum number of concurrent migration sessions?
a) 20 b) 30 c) 40 d) 50
04. How is the Allocated Capacity percentage for an SRP determined?
a) Calculated against the total unsubscribed capacity b) Calculated against the used capacity c) Calculated against the overall capacity d) Calculated against the total subscribed capacity
05. How many DAEs are in a fully-populated PowerMax 8000?
a) 8 b) 12 c) 16 d) 20
06. A systems administrator wants to present Gatekeeper devices to two standalone Microsoft Windows servers that run Solutions Enabler control operations. What information should be provided to the administrator?
a) Each host should have its own unique Gatekeepers
b) Hosts that run Solutions Enabler do not require any Gatekeepers c) Gatekeeper devices can be shared across hosts d) Gatekeeper devices should be no larger than 6 KB in size
07. In a local configuration, where is Unisphere and Solutions Enabler installed?
a) Host that has a direct connection to the Unisphere client b) Host that has a direct connection to the storage array c) In the guest operating system on the array d) In the tools guest on the array
DES 1121: Dell EMC PowerMax and VMAX Family Solutions Specialist for 5 Implementation Engineers
WWW.EDUSUM.COM PDF
08. How many pointers can be stored per Deduplication Management Object (DMO)?
5
8
10
16
09. In addition to the Solutions Enabler Base daemon, which other daemon is also mandatory at installation?
a) STP
GNS
SYMAPI Server
Event
10. What can be used to relink a TimeFinder SnapVX target?
a) Any snapshot of any source device
b) Any generation of the same snapshot only
Any snapshot of the same source device only
Same generation of a snapshot only
Answers:Answer 01:- c Answer 02:- b Answer 03:- d Answer 04:- c Answer 05:- b Answer 06:- a Answer 07:- b Answer 08:- a Answer 09:- c Answer 10:- c
DES 1121: Dell EMC PowerMax and VMAX Family Solutions Specialist for 6 Implementation Engineers
WWW.EDUSUM.COM PDF
a)
b)
c)
d)
b)
c)
d)
c)
d)