Exhibition Project - Spring 2020 - LBentley

Page 1

P H O E N I X F I R E S TAT I O N # 9 - M I D T O W N LADAWN BENTLEY ADE522 - ADVANCED ARCHITECTURAL STUDIO II


S TO RY L I N E

A fire station is an integral element in the location it serves. It embraces the neighborhoods, the urban edge, the businesses, and most of all, the people in the community. The new Midtown Fire Station #9 is in the heart of the financial district, near Osborn Road and Central in the downtown Phoenix. The concept for this fire station is to

extend a “welcoming hand to the community.�

The Midtown community is about coming together, sharing our neighborhoods, and embracing the nearby businesses. Fire stations help make connections within a neighborhood and embrace each other in unknown times of need, sickness, and resiliency. They are the key to

citizen engagement.

As a public entity serving

the community, a fire station engages the community, educates the public, and provides specialized training. Therefore, an essential first aid clinic is a necessary feature to implement into to help people with minor injuries since firemen are on duty twenty-four hours a day. In addition, a communal space is needed to gather for educational, cultural, or civic events. By embracing these affirmative actions of the community, the fire station becomes a true, imperative partner and leader for the growing Midtown area.

|2


SITE DEMOGRAPHICS

In the analysis of the site, the site analysis denotes the demographics of the people living in the area, their mdeian age, and the amount of families in the area. The Midtown fire station site is surrounded by the Encanto, Camelback East, and Encanto areas.

|3


S I T E U R B A N FA B R I C

The urban fabric of the site shows where the high-rise to low-rise buildings are located. It also evaluates the city infrastructure in relation to streets, hardscape, and landscaping. In addition, it denotes where applicable buildings are located such as schools, residential areas, healthcare facilities, and professional buildings are located. Lastly, the urban fabric shows what type of building materials are found on the surrounding buildings.

|4


S I T E F E AT U R E S

Landmarks: Phoenix Art Museum Heard Museum Phoenix Theatre Company St. Joseph’s Hospital Park Central Mall Pyramid on Central Phoenix Finantial Center Willo District (Historic) Palm Lane Steele Indian School Park Phoenix Country Club Encanto Park

Phoenix Art Museum

Phoenix Country Club

Park Central Mall

Phoenix Financial Center

|5


S I T E T R A N S I T L O C AT I O N S The transit locations are impairative to understanding where it is located in conjunction with the site. In addition, understanding where the pedestrian, bicycle, and bus routes are located helps provide an understanding to where these locations are relatively located to the potential Fire Station #9 site.

|6


|7


|8


SITE CONTEXT SITE AREA 147,600 SF (3.39 ACRES) TYPE

1

UNBUILT AREA (INFILL)

LOCATION FIRE STATION #9 16 E. COLUMBUS AVE. PHOENIX, AZ 85012 PARCEL NO.

118-33-063

PROGRAM 40% APPARATUS BAY 35% OFFICES 25% RESIDENTIAL SUSTAINABILITY

2

LEED SILVER

SITE DEVELOPMENT • ADJACENT HIGH-RISE DEVELOPMENT • HIGH-RISE RESCUE SUPPORT • ADJACENT TO UNITED PHOENIX FIREFIGHTERS FACILITY • EMBRACE THE COMMUNITY

1 2 3 4

VIEW FROM NORTH SIDE VIEW FROM EAST SIDE VIEW FROM SOUTH SIDE VIEW FROM WEST SIDE

3

4

|9


SITE INFLUENCES Indian School Park View to Piestewa Peak

Historic Neighborhood

7:40p

View Encanto Park

12p

5:23p

7:30a

l View to Estrella View Phoenix Mtns. Finanical Center

| 10

5:20a

Heavy Traffic Light Traffic Light Rail Bike Path

12p View to South Mtn.

Site Parameters View Line to Natural Features

Phoenix Country Club

View Line to Man-Made Features Sun Path - Winter Solice Sun Path - Summer Solice


SITE INFLUENCES COMMUNITY

TRAIN / PROTECT URBAN EDGE

FIRE STATION CONNECT

NEIGHBORHOOD

BUSINESSES | 11


PA R T I & D E S I G N C O N C E P T

1. DEFINE / EXTRUDE

4. INTEGRATE / USAGE

APPARATUS BAY OFFICE RESIDENTIAL CIRCULATION

2. DUPLICATE / CUT

3. ADJUST / BALANCE

| 12

5. DESIGN CONCEPT


SITE PLAN

E WELDON AVENUE BIOSWALES

BIOSWALES 25’ SETBACK

APP

ARA (5 B TUS BA AYS Y )

PUBLIC SPACE

RY O IT M R ING DO W

5’ SETBACK

ADM

INIS T WIN RATIV E G

PUBLIC AMPHITHEATER

CLINIC ENTRY MAIN ENTRY

EXIT 25’ SETBACK

BIOSWALES

BIOSWALES

5’ SETBACK

5’ SETBACK

TRAINING AREA

BIOSWALES

N FIRST ST

STAFF PKG.

5’ SETBACK

ENTRANCE

STREET PARKING

E COLUMBUS AVENUE

PROPERTY LINE

OCCUPANT CIRCULATION PEDESTRIAN CIRCULATION VEHICULAR CIRCULATION | 13


F I R S T L E V E L P L A N & C I R C U L AT I O N 39 RADIO / COMMUNICATIONS ROOM 40 ALTERNATE RESPONSE P PERSONNEL OFFICE 41 COVERED PATIO 42 UNISEX RESTROOM

0"

25 '-

0"

38

1

36

37

11

50' - 0"

10

28' - 0"

30 12

15' - 0"

8

8.5

42

20'

LOBBY

21

29

37

32

28

31 26

27

B UP

20

25

25' - 0"

25' - 0"

7

6

50'

C D

E 25' - 0"

5

25' - 0"

4

FLOOR PLAN & EGRESS - LEVEL 1 0'

23 23

34

22' - 0"

9

42

37

A

22

24

37

35

11

50' - 0"

41

20' - 0"

37

11' - 0"

26' - 0"

| 14

28

14

13

12.1 12

27

33

10 10

1

H.8

13

26

9

4

15' - 0"

UP

25' - 0"

8

6

30' - 0"

37 37

25' - 0"

30' - 0"

UP

5

J

37 37

39

L

3

32' - 0"

H.5

40

K

3

H

17

0"

41

M

UP

2

16

N

F.3

G

0"

28 '-

O

F

F.6

28 '-

25 '-

VESTIBULE RECEPTION CLINIC LOBBY EXAMINATION ROOM EMS STORAGE TRAINING / COMMUNITY ROOM MENS RESTROOM WOMENS RESTROOM STORAGE LIBRARY MECHANICAL ROOM FIRE RISER ELECTRICAL ROOM CONFERENCE ROOM BREAK ROOM CHIEF’S OFFICE BATTALION CHIEF’S OFFICE BATTALION OFFICE WATCH ROOM / STATION OFFICE

0"

20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38

APPARATUS BAY EXTERIOR STORAGE WORK ROOM /EQUIPMENT MAINTENANCE 4 FIRE EXTINGUISHER INSPECTION 5 HOSE STORAGE 6 EMS STORAGE 7 EMERGENCY GENERATOR 8 MECHANICAL 9 ELECTRICAL ROOM 10 UNISEX RESTROOM 11 TURN OUTS 12 LAUNDRY 13 DECOMTAMINATION 14 POLE LEGEND APPARATUS BAY RESIDENTIAL DORMITORY ADMINISTRATIVE CORRIDOR EGRESS PATH (UNDER 75’) EGRESS PATH (75’ - 150’) EXIT DOORS

25 '-

1 2 3

15

0"

ROOM NAMES FOR OFFICE AREA:

25 '-

ROOM NAMES FOR APPARATUS BAY:

100'

25' - 0"

3

25' - 0"

2

1


S E C O N D L E V E L P L A N & C I R C U L AT I O N ROOM NAMES FOR APPARATUS BAY:

ROOM NAMES FOR RESIDENTIAL:

1 2

20 21 22 23 24

14 15

25 '-

0"

25

27

25 25

0"

O

N

17

0"

25

25

25

27

25

0"

LEGEND APPARATUS BAY RESIDENTIAL ADMINISTRATION CORRIDOR EGRESS PATH (UNDER 75’) EGRESS PATH (75’ - 150’) EXIT DOORS

25

M

L

25

27

0"

7 8 9 10 11 12 13

28 '-

25 '-

LOBBY LARGE DINING ROOM / CONFERENCE ROOM DAY ROOM / BREAK ROOM MEN’S RESTROOM WOMEN’S RESTROOM ELECTRICAL MECHANICAL FITNESS / EXERCISE ROOM KITCHEN FOR CAPTAIN / CHIEF KITCHEN COVERED OUTDOOR PATIO

16

0"

P

25 '-

ROOM NAMES FOR OFFICE: 5 6

28 '-

CAPTAIN’S DORMITORY DORMITORIES MEN’S RESTROOM WOMEN’S RESTROOM BATTALION CHIEF DORMITORY 25 BATTALION DORMITORIES 26 LAUNDRY 27 COVERED PRIVATE PATIO

25 24

25 '-

STORAGE POLE

15

25 DN

25 25

27

26

K 23

21

21

B

DN

14

5

13

21

20' - 0"

21

11' - 0"

DN

2 16' - 0"

H

8

10 9

OPEN TO BELOW

1

8' - 0" 8' - 0"

H.8

21

12

7

11

13

1

3' - 0" 15' - 0"

12.1 12

50' - 0"

50' - 0"

11

28' - 0"

10

9

22' - 0"

8.5

15' - 0"

8

25' - 0"

7

25' - 0"

6

25' - 0"

5

25' - 0"

4

25' - 0"

25' - 0"

3

2

1

| 15

FLOOR PLAN - LEVEL 2 0'

20'

50'

100'

D

E

J 27' - 0"

C

25' - 0"

4' - 9"

26' - 0"

DN

20

A

6

25' - 0"

1

G

H.5

15

26

17' - 3"

F.3 F.6

22

8' - 0"

F


EAST

A N D S O U T H E L E VAT I O N MAIN LOBBY

DORMITORY

3

EXTERIOR ELEVATION - EAST 0'

20'

50'

APPARATUS BAY BAY 1

EXTERIOR STORAGE

BAY 2

BAY 3

BAY 4

FITNESS ROOM

BAY 5

DAY ROOM

2

| 16

EXTERIOR ELEVATION - SOUTH 0'

Insulated Metal Cladding System

Insulated Metal Cladding System

Insulated Metal Cladding System

Concrete Masonry Unit

100'

20'

50'

100'

MAIN ENTRANCE


FIRST & SECOND LEVEL - STRUCTURE

STEEL FLOOR / ROOF DECK-

APPARATUS BAY

DORMS AND OFFICE AREA

OFFICE

1

3D-STRUCTURAL-1&2

STEEL BEAMS AND COLUMNS | 17


FIRST & SECOND LEVEL - MEP

| 18


B U I L D I N G S E C T I O N - A P P A R A T U S B AY

| 19


W A L L S E C T I O N + R O O F D E T A I L - A P P B AY LADAWN BENTLEY ATE 556 ARCH. TECH. 5 ASSIGNMENT 5 - PART 3 - FINAL

4

APRIL 8, 2020

5

3D VIEW - APPARATUS BAY - TOP STRUCTURAL VIEW

3

3D VIEW - APPARATUS BAY - SECTION PERSPECTIVE

2

G

3D VIEW - APPARATUS B

3D VIEW - APPARATUS B

G.3 FLOOR PLAN LEVEL 5 30' - 0"

FRAMING PLAN LEVEL 3 25' - 0"

G G.3 G.6

G

H FLOOR PLAN LEVEL 2 15' - 0"

FLOOR PLAN LEVEL 5 30' - 0"

J J.5

FRAMING PLAN LEVEL 3 25' - 0"

J.8 K FLOOR PLAN LEVEL 1 0' - 0"

7

| 20

WALL SECTION 2 - APPARATUS WALL ENLARGED DETAIL 1 1/2" = 1'-0"

6

WALL SECTION 1 - APPARATUS BAY 1/2" = 1'-0"

12

1

FRAMING PLAN - LEVEL 3 1/16" = 1'-0"


D AY L I G H T I N G S O L U T I O N

| 21


RENDERED 3D MODELS - EXTERIOR


RENDERED 3D MODELS


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.