2 FILL
UDBS/IOP for ACTION Housing
Rain Chan-Kalin
Adriel Deller
Leto Karatsoli
Morgan Stampf
John Soh
ACTION
UPTOWN
PROPOSAL
INDEX INT RODU C TION GC IN IN IN IN PN PN
0.00 1.00 1.01 2.00 3.00 1.00 2.00
Cover Sheet Index: Table of Contents Index: Table of Contents Index: Notes and Stipulations Index: 'H¿QLWLRQV DQG /HJHQG Project Narrative: Introduction Project Narrative: Key Concepts
PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS
1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 2.00 2.01 2.02 2.03 3.00 3.01 4.00 4.01
Project Scope: 'HPRJUDSKLFV Project Scope: 'HPRJUDSKLFV Project Scope: 'HPRJUDSKLFV Project Scope: 'HPRJUDSKLFV Project Scope: Real Estate Project Scope: 'HPRJUDSKLFV Project Scope: 'HPRJUDSKLFV Project Scope: 'HPRJUDSKLFV Project Scope: Environmental Analysis Project Scope: Environmental Analysis Project Scope: Environmental Analysis Project Scope: Environmental Analysis Project Scope: 6LWH /RFDWLRQ Project Scope: 6LWH /RFDWLRQ Project Scope: /DQG 8VH DQG =RQLQJ 5HTXLUHPHQWV Project Scope: /DQG 8VH DQG =RQLQJ 5HTXLUHPHQWV
PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PP PP PP PP
5.00 5.01 5.02 6.00 7.00 7.01 8.00 8.01 9.00 9.01 9.02 9.03 10.00 10.01 10.02 10.03 10.04 11.00 11.01 1.00 1.01 1.02 1.03
CA CA CA CA
1.00 1.01 1.02 1.03
Code Analysis: %XLOGLQJ Code Analysis: %XLOGLQJ Code Analysis: %XLOGLQJ Code Analysis: %XLOGLQJ
SP SP SP
1.00 1.01 1.04
6SHFL¿FDWLRQV &6, 'HVLJQDWHG 0DWHULDO $QQRWDWLRQ /HJHQG 6SHFL¿FDWLRQV &6, 'HVLJQDWHG 0DWHULDO $QQRWDWLRQ /HJHQG 6SHFL¿FDWLRQV &6, 'HVLJQDWHG 0DWHULDO $QQRWDWLRQ /HJHQG 6SHFL¿FDWLRQV Wall Details
CONT EX T
T YPOLOGIES Project Scope: 6LWH 8WLOL]DWLRQ Project Scope: 6LWH 8WLOL]DWLRQ Project Scope: Cost Factors Project Scope: 6LWH 'HYLDWLRQ 8WLOL]DWLRQ Project Scope: Site Condition Project Scope: Site Condition Project Scope: Materials and Construction Project Scope: Materials and Construction Project Scope: +HDWLQJ (I¿FLHQF\ 6WUDWHJLHV Project Scope: +HDWLQJ (I¿FLHQF\ 6WUDWHJLHV Project Scope: +RPH (QHUJ\ &RQVXPSWLRQ Project Scope: +RPH (QHUJ\ &RQVXPSWLRQ Project Scope: 7\SRORJ\ &DVH 6WXG\ Project Scope: 7\SRORJ\ &DVH 6WXG\ Project Scope: 7\SRORJ\ &DVH 6WXG\ Project Scope: 7\SRORJ\ &DVH 6WXG\ Project Scope: 7\SRORJ\ &DVH 6WXG\ Project Scope: Precedent Project Scope: Precedent Project Proposal: 0DVVLQJ 6WXG\ Project Proposal: 0DVVLQJ Project Proposal: 3URJUDP Project Proposal: 3URJUDP
CODE ANA LYSIS
SPECIFIC ATION S
SP 1.03
IN 1.00
INDEX 7$%/( 2) &217(176
ACTION UPTOWN: 2FILL
ARC48_550
CONSTR U C TION D R AWIN GS AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT AT
1.00 1.01 1.02 1.03 1.04 1.05 2.00 2.01 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19
Adaptive Transformation: 1RUWKZHVW ([WHULRU 3HUVSHFWLYH Adaptive Transformation: 1RUWKHDVW ([WHULRU 3HUVSHFWLYH Adaptive Transformation: 6RXWKZHVW ([WHULRU 3HUVSHFWLYH Adaptive Transformation: 6RXWKHDVW ([WHULRU 3HUVSHFWLYH Adaptive Transformation: Plans Adaptive Transformation: Plans Adaptive Transformation: Sectional Perspective Adaptive Transformation: Sectional Perspective Adaptive Transformation: First Floor Plan Adaptive Transformation: First Floor Plan Adaptive Transformation: Second Floor Plan Adaptive Transformation: Second Floor Plan Adaptive Transformation: 7KLUG )ORRU 3ODQ Adaptive Transformation: 7KLUG )ORRU 3ODQ Adaptive Transformation: Wall to Floor Section Adaptive Transformation: Wall to Floor Section Adaptive Transformation: Corner Detail Plan Adaptive Transformation: Wall Plan Adaptive Transformation: Typical Construction Detail Adaptive Transformation: 'HVLJQ :DOO &RQVWUXFWLRQ 'HWDLO Adaptive Transformation: Wall to Roof Section Adaptive Transformation: Roof Detail Section Adaptive Transformation: Mansard Roof Section Adaptive Transformation: 7KLUG )ORRU %DWKURRP 6HFWLRQ Adaptive Transformation: Roof Terrace Wall Section Adaptive Transformation: Roof Terrace Wall Section Adaptive Transformation: )ODVKLQJ 'HWDLO Adaptive Transformation: )ODVKLQJ 'HWDLO
SD SD AS AS AS AS AS AS AS AS AS AS AS
1.00 1.01 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10
Selective Demolition: 6HTXHQFH Selective Demolition: 6HTXHQFH Assembly Sequence: 3LFWRUDO 'HSLFWLRQ RI 6WDJHG ,PSOHPHQWDWLRQ Assembly Sequence: 3LFWRUDO 'HSLFWLRQ RI 6WDJHG ,PSOHPHQWDWLRQ Assembly Sequence: 3LFWRUDO 'HSLFWLRQ RI 6WDJHG ,PSOHPHQWDWLRQ Assembly Sequence: 3LFWRUDO 'HSLFWLRQ RI 6WDJHG ,PSOHPHQWDWLRQ Assembly Sequence: 3LFWRUDO 'HSLFWLRQ RI 6WDJHG ,PSOHPHQWDWLRQ Assembly Sequence: 3LFWRUDO 'HSLFWLRQ RI 6WDJHG ,PSOHPHQWDWLRQ Assembly Sequence: ([WHULRU 3HUVSHFWLYH Assembly Sequence: ([WHULRU 3HUVSHFWLYH Assembly Sequence: ([WHULRU 3HUVSHFWLYH Assembly Sequence: Interior Perspective Assembly Sequence: Interior Perspective
IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP IMP
1.00 1.01 1.03 1.04 2.00 2.01 2.02 2.03 2.04 2.05 3.00 3.01 3.02 3.03 3.04 3.05 3.06 3.07 3.08 3.09 3.10 3.11 4.00
Implementation: ,PSOHPHQWDWLRQ 0HWKRGRORJ\ Implementation: /RJLVWLFV Implementation: *UDQWV DQG /RDQV Implementation: Contracts Implementation: &ULWLFDO 3DWK $QDO\VLV 3URMHFW 'HVLJQ Implementation: &ULWLFDO 3DWK $QDO\VLV 3URMHFW 'HVLJQ Implementation: &ULWLFDO 3DWK $QDO\VLV 3UH &RQVWUXFWLRQ Implementation: &ULWLFDO 3DWK $QDO\VLV 3UH &RQVWUXFWLRQ Implementation: &ULWLFDO 3DWK $QDO\VLV &RQVWUXFWLRQ Implementation: &ULWLFDO 3DWK $QDO\VLV &RQVWUXFWLRQ Implementation: Rent Structure Implementation: &RVW 'DWD 0HWKRGRORJ\ Implementation: 2YHUDOO &RVW %UHDNGRZQ Implementation: 2YHUDOO &RVW %UHDNGRZQ Implementation: Hard Cost Analysis Implementation: Hard Cost Analysis Implementation: Hard Cost Analysis Implementation: Hard Cost Analysis Implementation: Hard Cost Analysis Implementation: Hard Cost Analysis Implementation: Hard Cost Analysis Implementation: Hard Cost Analysis Implementation: +RPH 2ZQHU %XGJHW
ASSEMBLY SEQU EN C E
IMPLEMEN TATION
INDEX 7$%/( 2) &217(176
IN 1.01
WHAT YOU NEED TO KNOW ABBREVIATIONS & @ FT. L.F.
MAX. MECH. MIN. REQ. S.F. O.C. DET. SIP. AXON
SYMBOLS KEY
AND AT FEET LINEAR FEET MAXIMUM MECHANICAL MINIMUM REQUIRED SQUARE FEET ON CENTER DETAIL STRUCTURAL INSULATED PANEL AXONOMETRIC
N S E W NE NW SE SW O.C. KW YR MISC
NORTH SOUTH EAST WEST NORTHEAST NORTHWEST SOUTHEAST SOUTHWEST OFF CENTER KILLOWATT YEAR MISCELANEOUS
DRAWING TITLE
SECTION CUT
KEY NOTE
WALL TAG
WINDOW TAG
DEFINITIONS R Value: Thermal resistance of a material. The inverse of the time rate of KHDW À RZ WKURXJK D ERG\ IURP RQH RI LWV ERXQGLQJ VXUIDFHV WR WKH RWKHU for a unit temperature difference between the two surfaces, under steady state conditions, per unit area (h * ft2 * oF)
ROOM TAG
DETAIL
SAFETY STIPULATIONS 1. General: All work to be done in accordance with the Allegheny County Building Code and regulations of all other agencies having jurisdiction.
NOTE
ALIGN TAG
2. Structural: Contractor to provide adequate temporary bracing and shoring wherever any structural work is involved. 3. Means of Egress: All existing means of egress for tenants of the building to be maintained clear and free of all obstructions, such as building materials, tools, ect. 4. Fire Safety: All building materials stored at construction area, and/or in any area of the building are to be secured in a locked area. Access to such areas to be controlled by Owner and/or General Contractor. 5. Dust Control: debris, dirt, and dust to be kept to a minimum, and be FRQ¿ QHG WR WKH LPPHGLDWH FRQVWUXFWLRQ DUHD DQG EH FOHDQHG XS DQG cleared from building periodically to avoid any excessive accumulation. 1RLVH $IWHU +RXUV FRQVWUXFWLRQ RSHUDWLRQV ZLOO EH FRQ¿ QHG WR QRUPDO working hours 9 a.m. to 5 p.m. Monday through Friday, except holidays, unless an After-Hours Work Permit is secured from the Department of Buildings.
IN 2.00
INDEX 127(6 $1' 67,38/$7,216
EXTERIOR SECTION TAG
EXTERIOR ELEVATION TAG
ELEVATION HEIGHT
DETAIL CALL OUT
INTERIOR ELEVATIONS TAG
ACTION UPTOWN: 2FILL
ARC48_550
BOOK NOTES 1. These documents are the copyrighted intellectual property of Carnegie Mellon University and its authors. The documents are not to be reproduced or utilized for any purpose other than originally stipulated on the cover sheet and title block. 2. None of the documents included in drawing index are intended to be considered in isolation of one another, all parties utilizing these documents for bidding, quantity, survey, and/or construction shall consult the general notes and information located on this sheet and all other sheets before proceeding. 3. All work shall conform to the requirements of the Pennsylvania Building Code, Pittsburgh Fire Department regulations, Utility company requirements, and the best trade practices. %HIRUH FRPPHQFLQJ ZRUN WKH FRQWUDFWRU VKDOO ÂżOH DOO UHTXLUHG &HUWLÂżFDWHV RI ,QVXUDQFH ZLWK WKH 'HSDUWPHQW RI %XLOGLQJV REWDLQ DOO UHTXLUHG permits, and pay all fees required by governing agencies. 7KH &RQWUDFWRU VKDOO YHULI\ DOO H[LVWLQJ FRQGLWLRQV LQ WKH ÂżHOG SULRU WR FRPPHQFLQJ ZRUN DQG VKDOO UHSRUW DQ\ GLVFUHSDQFLHV EHWZHHQ GUDZLQJV DQG ÂżHOG FRQGLWLRQV WR WKH $UFKLWHFW 0LQRU GHWDLOV QRW XVXDOO\ VKRZQ RU VSHFLÂżHG EXW QHFHVVDU\ IRU SURSHU FRQVWUXFWLRQ RI DQ\ SDUW RI WKH ZRUN VKDOO EH LQFOXGHG DV LI WKH\ ZHUH indicated in the drawings. 7. The Contractor shall coordinate all work procedures with requirements of local authorities and building management. 8. The Contractor shall be responsible for the protection of all conditions and materials within the proposed construction area. The Contractor shall design and install adequate shoring and bracing for all structural and removal tasks. The Contractor shall have sole responsibility for any damage and injuries caused by or during the execution of the work. 9. The Contractor shall lay out his/her own work, and shall provide all dimensions required for other trades (plumbing, electrical, ect.) 10. The Contractor, Owner, and all parties involved in construction shall consider all building costs provided by the Architect as opinions of cost and recognize the costs may change due to unforeseen circumstances. 11. Plumbing and electrical work shall be performed by persons licensed in their trades, who shall arrange for and obtain inspections and required sign-offs. 12. The Contractor shall do all cutting, patching, repairing as required to perform all of the work indicated on the drawings, and all other work that may be required to complete the job. 13. The Contractor, upon completion of the work, shall arrange for Department of Buildings inspections and signoffs as required. 14. Work shall conform to PA Building Code and all applicable State and City Building Laws. 15. Plumbing work to be performed by Licensed Plumber in accordance with the PA Building Code. 16. Electrical work to be performed by Licensed Electrician in accordance with the PA Building Code.
INDEX '(),1,7,216 $1' /(*(1'
IN 3.00
INTRODUCTION ZKR
ACTION HOUSING
7KH PLVVLRQ RI $FWLRQ +RXVLQJ LV WR HPSRZHU SHRSOH WR EXLOG PRUH VHFXUH DQG VHOI VXIÂż FLHQW OLYHV WKURXJK WKH SURYLVLRQ of decent, affordable housing, essential supportive services, asset building programs, and educational and employment RSSRUWXQLWLHV $V DQ H[WHQVLRQ RI WKDW FHQWUDO PLVVLRQ $&7,21 +RXVLQJ OLQNV LWV DFWLYLWLHV ZLWK RWKHU SXEOLF QRQ SURÂż W and private entities in a common effort to address the needs of their clients. The organization provides decent, safe, and DIIRUGDEOH KRXVLQJ IRU WKH PRVW YXOQHUDEOH SRSXODWLRQV GHVSLWH WKHLU SK\VLFDO GHYHORSPHQWDO DQG LQFRPH OLPLWDWLRQV demonstrating leadership in the implementation of innovative technology in the delivery and management of social services. ARCH48_550 Action Uptown Project Description, John Folan
ISSUES OF PRACTICE COURSE Students of the Issues of Practice course taught by John Folan were grouped in teams and worked with Action Housing WR SURSRVH DIIRUGDEOH KRXVLQJ GHVLJQV 6WXGHQW JURXSV FRPSULVHG RI IRXUWK DQG ¿ IWK \HDU DUFKLWHFWXUH VWXGHQWV SXUVXLQJ a professional bachelor’s degree in architecture.
?
ZKHQ
September 2012 - December 2012
The 2Fill project was conceived and documented between September 2012 and December 2012. If any documents from the 2Fill proposal are desired by Action Housing or another entity after December 15th, 2012 please contact Carnegie Mellon University, Department of Architecture.
ZKHUH
UPTOWN, PITTSBURGH
?
Uptown is located in a strategic location in Pittsburgh because of its strong connectivity and proximity to Downtown and Oakland. Uptown is also near some of the business and employment engines of the city such as UPMC Mercy, Duquesne University, and Carlow University. This gives the Uptown community great potential to be reactivated and revitalized by young professionals who want to live near their work and invest in affordable housing options.
PN 1.00
PROJECT NARRATIVE ,1752'8&7,21
ACTION UPTOWN: 2FILL
ARC48_550
ZK\
IMPROVING QUALITY OF LIFE Unfortunately, Uptown has been facing a slow decline during which time people have left the area, real estate prices have fallen, businesses have closed, and unemployment has risen. By creating affordable housing options in the area that will foster a sense of personal and community pride we expect that this cycle will be EURNHQ DQG WKDW WKH FRPPXQLW\ FDQ EHJLQ WR À RXULVK RQFH DJDLQ
ZKDW
AFFORDABLE HOUSING :H DUH SURSRVLQJ D UHVLGHQWLDO EXLOGLQJ WKDW FRQWDLQV WZR UHVLGHQFHV DQ HI¿ FLHQF\ XQLW DQG D WZR ¹ EHGURRP unit. We believe that with this model the owners have the opportunity to afford a higher quality construction of the home because they will be able to rent out one of the two residences. This will makes the 2Fill typology more HFRQRPLFDOO\ IHDVLEOH WR FRQVWUXFW DQG PRUH SUR¿ WDEOH IRU WKH RZQHUV JLYLQJ WKHP D WDQJLEOH LQFHQWLYH WR GR VR Heating and cooling bills can become a real burden for residents who are below the median income level. One of Action Housing’s main premises is to design and construct houses that will minimize the cost of heating and FRROLQJ %\ FRQVWUXFWLQJ D PRUH HQHUJ\ HI¿ FLHQW KRPH WKHUH LV OHVV EXUGHQ RQ WKH IDPLO\ OLYLQJ LQ WKH KRPH WR pay high utility bills. Money that is earned from the rent and that is not spent on utilities can be spent in local shops to further improve the community and attract more people to move to Uptown.
KRZ
THOUGHTFUL DESIGN :H DUH DSSURDFKLQJ WKLV LQWHUYHQWLRQ DV D W\SRORJLFDO KRXVLQJ VWUDWHJ\ WKDW FRXOG EH XVHG LQ WKH RWKHU LQÂż OO VLWHV making a greater impact. This intervention, if used as a typology that is implemented in multiple lots throughout Uptown, will begin to form a system of houses that will serve as catalysts for growth and higher density in the area.
PROJECT NARRATIVE .(< &21&(376
PN 2.00
CONT
TEXT
DEMOGRAPHICS
Vacancy Around Uptown
.
Department of City Planning, Pittsburgh GIS http://www.pittsburghpa.gov based on Census 2010
Vacancy 7ZHQW\ VHYHQ SHUFHQW RI SURSHUWLHV LQ 8SWRZQ DUH YDFDQW 7KHUH LV a particularly high concentration of vacancy in our area of focus, in the residential and commercial buildings between Seneca Street DQG -XPRQYLOOH 6WUHHW 2I WKHVH YDFDQW ORWV ZH KDYH LGHQWLÂż HG D VSHFLÂż F JURXS RI ORWV WKDW ZH KDYH LGHQWLÂż HG DV FDVH VWXGLHV LQ D YDFDQF\ Âż OO ORW W\SRORJ\ 7KH YDFDQW ORWV RI 7XVWLQ 6WUHHW 2003 Tustin Street, 2007 Tustin Street, 2022 Fifth Avenue, and our lot, 2026 Forbes Avenue, are each surrounded on neighboring sides by built lots. The vacant lots themselves either act as green side lots or are being used for parking or extended backyard by their neighbors. These lots exist along streets were there is a highly continuous streetfront of built properties. These lots act as missing teeth in what could be a highly developed neighborhood. The design proposal for our lot at 2026 Forbes Avenue is HQYLVLRQHG DV D YDFDQF\ LQÂż OO ORW W\SRORJ\ 7KH SURSRVDO GRHV not only consider the impacts of its immediate adjacancies, but is meant to address the demographic needs of the neighborhood for insertion into various vacant lots with similar characteristics throughout the neighborhood.
PS 1.00
PROJECT SCOPE '(02*5$3+,&6
9DFDQF\ ,QÂż OO /RW 7\SRORJ\ 6WXG\ Vacant Lots in Uptown Parcel ID
Mailing Address
Current Condition
5 11K163
2034 FORBES AVE
VACANT
6 11K164
2036 FORBES AVE
VACANT
7 11K165
2038 FORBES AVE
VACANT
8 11K167
2040 FORBES AVE
VACANT
9 11K162A
TUSTIN ST
VACANT
10 11K155
2027 TUSTIN ST
VACANT
11 11K152
2025 TUSTIN ST
VACANT
12 11K99
2018 WATSON ST
VACANT
13 11K36
2038 FIFTH AVE
VACANT
14 11K34
2036 FIFTH AVE
VACANT
15 11K25
2016 FIFTH AVE
MUNICIPAL GOVâ&#x20AC;&#x2122;T
16 11K24
2014 FIFTH AVE
VACANT
17 11K23
2012 FIFTH AVE
VACANT
9DFDQF\ ,Q多 OO /RW 7\SRORJ\ 6WXG\
ACTION UPTOWN: 2FILL
project site
Parcel ID: 11K157 Mailing Address: 2026 FORBES AVE Current Condition: VACANT Lot Area: 1,463 sq ft. Assessed Value: $1,300 Owner: ARDELLA Owner Residence: UPTOWN
Fifth Ave
4
17 16 15
14 13
Watson St
12
5 6 7 8 2 1
1110
Seneca St
Jumonville St
9DFDQF\ /RW &DVH 6WXGLHV
Forbes Ave
3
ARC48_550
9
Tustin St
Department of City Planning, Pittsburgh GIS http://www.pittsburghpa.gov based on Census 2010
Lots at 2007 Tustin Street, 2002 Tustin Street, 2003 Tustin Street, and 2022 Fifth Avenue have similar characteristics to our project site, 2026 Forbes Avenue. These vacant lots sit along a strip of developed lots and are missing teeth along the street front. These lots are either grass side lots or are being utilized by their neighbors. Each of these lots are zoned within a residential area WKDW FRXOG EHQH多 W IURP WKH LQWURGXFWLRQ RI QHZ residential units to create a sense of continuity. The design proposal for 2026 Forbes Avenue is PHDQW WR DFW DV D YDFDQF\ LQ多 OO ORW W\SRORJ\ IRU these vacant lot case studies.
9DFDQF\ ,Q多 OO /RW 7\SRORJ\ 6WXG\ Vacant Lots Case Studies
1 2
Parcel ID: Mailing Address: Current Condition: Lot Area: Assessed Value: Owner: Owner Residence: Parcel ID: Mailing Address: Current Condition: Lot Area: Assessed Value: Owner: Owner Residence:
11K141A 2007 TUSTIN ST VACANT 504 sq ft. $1,400 THOMPSON PENN HILLS 11K271 2002 TUSTIN ST VACANT 675 sq ft. $3,600 FULKS UPTOWN
3 4
3DUFHO ,' . Mailing Address: 2003 TUSTIN ST Current Condition: VACANT Lot Area: 519 sq ft. Assessed Value: $900 Owner: RAYMOND Owner Residence: UPTOWN Parcel ID: Mailing Address: Current Condition: Lot Area: Assessed Value: Owner: Owner Residence:
PROJECT SCOPE '(02*5$3+,&6
11K28 2022 FIFTH AVE VACANT 2,640 sq ft. $1,700 JOSEPHUS UPTOWN
PS 1.01
Property Value
Property Value Adjacent to Site
The property value of buildings between Seneca Street and Jumonville Street is much lower than other neighborhoods within Pittsburgh. The contributing factors to this diminished property value seem to EH WKH KLJK YDFDQF\ UDWH WZHQW\ VHYHQ percent) and the side Less underdeveloped Than $10,000 lots that break $10,000-$20,000 the continuity of building $20,000-$30,000 DORQJ WKH VWUHHW 6L[W\ VL[ SHUFHQW RI $30,000-$40,000 $40,000-$50,000 WHQXUHG EXLOGLQJV LQ 8SWRZQ DUH UHQWHU $50,000-$60,000 occupied. This $60,000-$70,000 high percentage is most $70,000-$80,000 likely attributed to Uptownâ&#x20AC;&#x2122;s context within $80,000-$90,000 $130,000-$140,000 the city of Pittsburgh. Uptown is located next to Downtown, making it a potentially desirable location for commuters into Downtown to reside. The poor condition of properties, low property values, and high level of vacancy attribute to the low morale and poor image of the neighborhood. The redevelopment and maintainence of many of the current buildings and vacant side lots within Uptown will lead to a surge in occupied buildings. A higher level of occupancy will led to a boasted neighborhood morale and increase property value within Uptown.
27.8%
Department of City Planning, Pittsburgh GIS http://www.pittsburghpa.gov based on Census 2010
Existing Buildings
highest value
lowest value 27.8%
Income
72.2%
49.1% 72.2%
48.1%
Building Vacancy-Tenure Status 0.9%
The majority of people living in Uptown make less than $10,000 per year, much less than the average for all of Pittsburgh. By splitting our property into two units, the price per renter will diminish, reducing the investment that each occupant must put into the cost of home. A focus on affordable housing is crucial to reinvigorating the residential areas and achieving a greater level of occupancy.
vacancy status
housing status 27.8%
tenure status 23%
49.1%
72.2%
66%
48.1%
11%
0.9%
key
Occupied Vacant
key 49.1%
23%
48.1%
1.9%
1.9%
key
For Rent For Sale Sold, Not Occupied Other Vacant
Renter-Occupied Owned with Mortgage or Loan Owned Free and Clear
66% 11%
0.9%
PS 1.02
PROJECT SCOPE '(02*5$3+,&6 11%
1.9%
23% 66%
Department of City Planning, Pittsburgh GIS http://www.pittsburghpa.gov based on Census 2010
Population Breakdown Employment
ACTION UPTOWN: 2FILL
City of Pittsburgh 1HLJKERUKRRG 3URÂż OHV Census 2010
ARC48_550
9% 9%
80%
key
Female Male
key
Employed Unemployed
60%
27% 27%
40%
10%
2%
other
HGXFDWLRQ social services
transportation XWLOLWLHV
public administration
Âż QDQFLDO insurance services ZKROHVDOH retail services
Employment
88%
Population Breakdown Income
10%
2%
88%
$83,386
key
2%
$55,013
Less Than $10,000 $10,000 - $25,000 $25,000 - $40,000
10%
88%
key
Uptown Pittsburgh
The majority of the residents in Uptown are employed within educational and social services, wholesale and retail services, Âż QDQFLDO DQG LQVXUDQFH VHUYLFHV WKH manufacturing sector, and other atypical job settings. Uptown offers little in the way of employment opportunities for these job sectors. Therefore, one can assume that the majority of Uptownâ&#x20AC;&#x2122;s residents must commute outside of the neighborhood to go to work. Uptown is blessed with several bus lines that enable residents to easily rely on public transportation to commute to work. Residents working in Downtown have a short six minute bus ride to commute to work everyday. This is the most desirable factor for attracting working residents to live in Uptown. Therefore, our targeted demographic for WKH YDFDQF\ LQÂż OO ORW W\SRORJ\ LV \RXQJ professionals. We are developing our site LQWR WZR DSDUWPHQW XQLWV WKH Âż UVW OHYHO LV D one bedroom unit and second and third levels are a starter family unit. This user base will JUHDWO\ EHQHÂż W IURP 8SWRZQÂśV FORVH SUR[LPLW\ to Downtown and public transit amenities. They will in turn boost ridership, investing in the future of Port Authority develop.
$555
median single home value median attached home value
Department of City Planning, Pittsburgh GIS http://www.pittsburghpa.gov based on Census 2010
median rent
88%
median income
2%
$9,968
Less Than $10,000 $10,000 - $25,000 $25,000 - $40,000
10%
Employed Unemployed
employment status
manufacturing sector
construction industry
20%
key
PROJECT SCOPE '(02*5$3+,&6
PS 1.03
DEMOGRAPHICS Synthesis Real Estate Analysis Shadyside $12-22/Sf/Yr
East Liberty $17/Sf/Yr
3 7
Shadyside $12-22/Sf/Yr
2
Shadyside $12-22/Sf/Yr
1
East Liberty $17/Sf/Yr
4
9
6
8 East Liberty $17/Sf/Yr
Shadyside East Liberty Southside $12-22/Sf/Yr Uptown $17/Sf/Yr Squirrel Hill $10-15/Sf/Yr $6-16/Sf/Yr $17/Sf/Yr 1HLJKERUKRRG Property
1
5
'RZQWRZQ
Value
+RXVHKROG Income
$10-33/sf/yr
$114,000
Area Home Vacancy %
2 'XTXHVQH +HLJKWV $42,000 $15/sf/yr Shadyside East Shadyside East Liberty Liberty $12-22/Sf/Yr $17/Sf/Yr $12-22/Sf/Yr Shadyside East Liberty 3 (DVW /LEHUW\$17/Sf/Yr $36,000 $17/sf/yr 00 $12-22/Sf/Yr $17/Sf/Yr Uptown Squirrel Hill Southside 4 2DNODQG $48,000 $15-28/sf/yr Downtown Downtown $10-15/Sf/Yr $6-16/Sf/Yr $17/Sf/Yr This graph is supposed to show the value 5
6KDG\VLGH
6
6TXUULHO +LOO
Duquesne Heights Heights Duquesne East Liberty Liberty East Oakland Oakland
Southside Shadyside Shadyside 7 $17/Sf/Yr Squrriel Squrriel Hill Hill Shadyside Strip District District 8 Strip 00 $12-22/Sf/Yr Southside
00
Southside Southside
$17/Sf/Yr Uptown Uptown Downtown
9
Uptown
Strip District $10-15/Sf/Yr
East Liberty
Uptown $10-15/Sf/Yr Uptown
East Liberty Oakland Shadyside
Southside Downtown Oakland Uptown Duquesne Heights Shadyside East Liberty Squrriel Hill Oakland Strip District Shadyside Southside
the value of other neighborhoods in pittsburgh. $66,000 $6-16/sf/yr We need Squirrel Hill a good graphic comparison of $36,000 $10-16/sf/yr the districs to one another. $6-16/Sf/Yr
6RXWKVLGH $17/Sf/Yr $17/sf/yr
Duquesne Heights
Downtown Southside Southside Squrriel Hill Duquesne Heights 00$17/Sf/Yr $17/Sf/Yr Southside Strip District East Liberty $17/Sf/Yr
0 0
of the property$84,000 in uptown as compared to $12-22/sf/yr
Uptown Uptown $10-15/Sf/Yr $10-15/Sf/Yr Uptown $10-15/Sf/Yr
PS 1.04
Squirrel Hill $6-16/Sf/Yr $10-15/sf/yr
$36,000 $12,000
This graph is supposed to show the value of the property in uptown as compared to the value of other neighborhoods in pittsburgh. We need a good graphic comparison of the Hill districs to one another. Squirrel Squirrel ThisHill graph is supposed to show the value $6-16/Sf/Yr $6-16/Sf/Yr of the Squirrel Hillproperty in uptown as compared to the value of other neighborhoods in pitts$6-16/Sf/Yr burgh. PROJECT SCOPE This graph is supposed to show the value We need a good graphic comparison of 5($/ (67$7( of the property in uptown as compared to the districs to one another. the value of other neighborhoods in pittsburgh. We need a good graphic comparison of the districs to one another.
Real Estate In comparison to other neighborhoods within Pittsburgh, Uptownâ&#x20AC;&#x2122;s percentage of vacancy is one of the highest and its residentsâ&#x20AC;&#x2122; household income is one of the lowest. These factors are RQO\ VRPHZKDW UHĂ&#x20AC; HFWHG LQ WKH FRVW SHU VTXDUH IRRW SHU \HDU RI SURSHUW\ 7KH YDOXH LV VLJQÂż FLDQWO\ less than Downtown, but in comparison to other neighborhoods that are in considerably better shape than Uptown, such as Squrriel Hill, Oakland, East Liberty, and Shadyside, the cost in either equal to or only a few dollars less. Therefore, there is a great need to invest in affordable, yet high quality residential building in Uptown. The property value is most likely so due to Uptownâ&#x20AC;&#x2122;s DGMDFDQF\ ZLWK 'RZQWRZQ EXW LV QRW UHĂ&#x20AC; HFWLYH in the current quality of the neighborhood or the rate of income per household. In order to attract and maintain new residents in the neighborhood, a focus on building and redeveloping through affordable means is crucial.
ACTION UPTOWN: 2FILL
Population Breakdown Ethnicity
&LW\ RI 3LWWVEXUJK 1HLJKERUKRRG 3URÂż OHV &HQVXV
key
mixed race
ARC48_550
2000 Census 2010 Census
hispanic caucasian africanamerican asian
0-19
Population Breakdown Age
20-34 0-19 35-59 20-34 60-74 35-59 +75 60-74 +75
(WKQLFLW\ DQG $JH
0-19 years 20-34 years 35-59 years 60-74 years 75+ years
= 200 people
= 200 people = 200 people
The population of Uptown has a majority of Caucasian and African American residents with a small population of hispanic, asian, and mixed race ethnicities. The population has been grown between 2000 to 2012 with the same ethnicity trends. A large population living within the neighborhood boundaries of Bluff are students from Duequesne University. For the VDNH RI XQGHUVWDQGLQJ WKH G\QDPLFV RI ORQJ WHUP UHVLGHQWV we have separated Duquesne students from the rest of the Uptown population. With this taken into account, The largest populations are between the ages of twenty to thirty three \HDUV ROG DQG WKLUW\ Âż YH WR Âż IW\ QLQH \HDUV ROG 5HVLGHQWLDO buildings within Uptown should therefore target the young professional, starter families, and established families. We DUH ORRNLQJ WR VSHFLÂż FDOO\ WDUJHW WKH \RXQJ SURIHVVLRQDO XVHU base. primarily because we believe that this demographic will help to generate positive charges within the neighborhood. Young professionals will boost public transit ridership, will bring new, refreshing ideas for developing the community, and will hopefully establish themselves within the neighborhood to extend for a long period of time.
PROJECT SCOPE '(02*5$3+,&6
PS 1.05
Population Breakdown Education
&LW\ RI 3LWWVEXUJK 1HLJKERUKRRG 3URÂż OHV &HQVXV
60%
key
Education The majority of the population in Uptown has achieved some level of education in college. For those who have achieved collegiate degrees, women make up the largest percentage. Our targeted user demographic, the young professional, will have graduated college or vocational school. This demographic is more inclined to be a leader in the community, encouraging the growth in neighborhood image and morale.
Female Male
45%
30%
15%
PS 1.06
PROJECT SCOPE '(02*5$3+,&6
Population Breakdown Household
67.7%
6.4%
doctorate degree
masters degree
bachelors degree
vocational training
associates degree
some college
grade 12
grade 11
grade 10
grade 9
The majority of the households in Uptown consist of either a single person living by his or herself or a parent living with a child. The primary housing type in Uptown is the rowhouse, a unit that is often times too large for a single homeowner to afford DQG PDLQWDLQ ,Q RUGHU WR Âż W LQWR WKH FXUUHQW housing typology while accommodating this XVHU SURÂż OH WKH URZKRXVH FDQ EH EURNHQ down into a shared building of smaller units to house multiple owners or renters. The Âż UVW Ă&#x20AC; RRU RI RXU EXLOGLQJ LV D VLQJOH EHGURRP residential unit for one or two people. The VHFRQG DQG WKLUG Ă&#x20AC; RRUV RI RXU EXLOGLQJ are a starter familiy residential unit. The primary resident demographic of each of these units is the young professional. The young professional will spend a minimum RI Âż YH WHQ \HDUV OLYLQJ LQ WKH XQLW ZKLOH WKH\ GHYHORS WKHPVHOYHV Âż QDQFLDOOO\ :LWK the perks of reliable public transportation and a developing community hopefully the resident will be encouraged to settle him or her self longterm in Uptown.
none
+RXVHKROG
Department of City Planning, Pittsburgh GIS http://www.pittsburghpa.gov based on Census 2010, Google Maps
16.0%
9.9%
Department of City Planning, Pittsburgh GIS http://www.pittsburghpa.gov based on Census 2010, Google Maps
ACTION UPTOWN: 2FILL
Transportation Bus Routes
Department of City Planning, Pittsburgh GIS http://www.pittsburghpa.gov based on Census 2010, Google Maps
Transportation
Bentley Drive
Bentley Drive
Bentley Drive
Transportation Pittsburgh Connections
East Liberty Shadyside Downtown
Oakland Transportation Analysis Bus Routes
Bentley Drive Uptown
Braddock Squirrel Hill
key
SouthsideTransportation Analysis Bus Routes 71 Bus
61, 67, 69 Bus
54 Bus
Transportation Bus Stops Near Site
Department of City Planning, Pittsburgh GIS http://www.pittsburghpa.gov based on Census 2010, Google Maps
ARC48_550
Pittsburghers utilize public transportation more than many U.S. cities with comparable populations. )RUW\ ¿ YH WR ¿ IW\ SHUFHQW RI GRZQWRZQ commuters get to work using public transportation. Nine bus lines run through Uptown everyday, and at peak commuting hours, residents of Uptown can catch a bus along Fifth Avenue every minute to commute to Downtown. The bus ride between Uptown and Downtown is only a six minute trip. In addition to Downtown, public transportation creates strong, reliable connections from Uptown to other neighborhoods surrounding Downtown, particularly Oakland, Squrriel Hill, Shadyside, and East Liberty. Due to Uptown’s central location and its strong public transit system, Uptown has the potential to be a prime location for residential ownership of rent of affordable units, particularly for young professionals. Uptown as a community would greatly EHQH¿ W IURP LQFUHDVLQJ WKLV XVHU demographic in the neighborhood. Young professionals would have a strong reliance on the public transit, increasing ridership. Companies would be more inclined to develop in the area, attacting young professionals to work there, increasing property value and neighborhood identity. Fifth Avenue and Forbes Avenue are strong axes within the city of Pittsburgh, connecting a series of neighborhoods to Downtown. Uptown has a central location along these axes and is the closest neighborhood to Downtown. Our site sits right along Forbes Avenue through which several bus lines pass along everyday. A resident of our proposed residential units can walk to the corner of Seneca Street and Forbes Avenue to easily reach
PROJECT SCOPE '(02*5$3+,&6
PS 1.07
ENVIRONMENTAL ANALYSIS 6800(5
WINTER
winter 12p
summer9AM 9am
winter12PM 9am
SUMMER 3p
SUMMER 3PM12PM
winter 3pm
The apartments have been designed to provide adequate lighting in summer while keeping heat gain to a minimum. Skylights allow light to penetrate deep into the building where windows are impossible due to the adjacent buildings. Because heat gain is a concern in summer, efforts have been made to shelter the interiors from intense light. The VHFRQG VWRU\ KHOSV VHOI VKDGH WKH Âż UVW VWRU\ DQG DSDUWPHQW &XWWLQJ down on solar gain helps lower cooling costs during Pittsburghâ&#x20AC;&#x2122;s hot, humid summers, reducing the impact both on residentsâ&#x20AC;&#x2122; comfort and Âż QDQFHV
PS 2.00
PROJECT SCOPE (19,5210(17$/ $1$/<6,6
Windows and overhangs have been designed to allow sun to penetrate deep into the building during winter. This helps on two accounts: with reducing DUWLÂż FLDO OLJKWLQJ QHHGV GXULQJ WKH GD\ DQG KHOSLQJ WR EXLOG XS KHDW GXULQJ the day that will last into the night. Lower sun angles in winter allow light to reach all the way to the north side of the apartments through the windows DQG VN\OLJKWV GD\OLJKWLQJ WKH PDMRULW\ RI WKH EXLOGLQJ 3LWWVEXUJK LV D KHDWLQJ KHDY\ FOLPDWH ZLWK EHORZ IUHH]LQJ WHPSHUDWXUHV +HDWLQJ FRVWV FDQ EH crippling, so along with tight seals, insulation, and a sensitivity to passive heat gain, the residentsâ&#x20AC;&#x2122; utilities bills can be greatly reduced.
n
pr
ACTION UPTOWN: 2FILL
ARC48_550
Winter
n
pr
Summer
Summer Wind Penetration Passive cooling techniques supplement an emphasis on tight seals and insulation. In the summer, prevailing winds come from the southwest. With the back RI WKH KRXVH IDFLQJ GLUHFWO\ VRXWK ZLQGRZV FDQ EH RSHQHG RQ WKH QRUWK DQG VRXWK IDFDGHV WR OHW DLU SDVV WKURXJK DQG Ă&#x20AC; XVK RXW DFFXPXODWHG KHDW 6N\OLJKWV when open, can help vent hot air up and out of the building, at which points prevailing winds will carry it away. 7KH LQWHULRUV RQ HDFK Ă&#x20AC; RRU ZHUH GHVLJQHG OLQHDUO\ WR DOORZ IRU XQLQWHUUXSWHG ZLQG Ă&#x20AC; RZ RQ WKH QRUWK VRXWK D[LV These passive techniques reduce active cooling needs, which helps cut down on utility costs for residents.
t UP
DN
DN
DN
t
1st Floor Apartment 1
2nd Floor Apartment 2
3rd Floor Apartment 2
PROJECT SCOPE (19,5210(17$/ $1$/<6,6
PS 2.01
N
ENVIRONMENTAL ANALYSIS ([LVWLQJ &RQGLWLRQV
Passive System Studies
Adjacent houses use gas furnaces and water heaters that could date back to the 1990’s. Due to age DQG LPSURSHU HQHUJ\ ORDG FDOFXODWLRQV WKH KHDWLQJ HTXLSPHQW FRXOG KDYH DQ HI¿FLHQF\ UDWH RI GRZQ WR 50%. The exterior of piping and the basement, where equipment is housed are either uninsulated or insulated very poorly. Lot 157 contains gas, water, and electricity connections below the paved parking area.
Systems Passive heating and cooling systems, when integrated well into the home, can be an easy way to allow for more affordable utilities. Some proposed examples include:
Thermal Mass on Southern Facade
Solar Orientation +Shading Shading the home from the scorching summer sun while harnessing the heat RI WKH VXQOLJKW WKURXJK ZHOO RULHQWHG windows. Wind Orientation Harnessing natural wind patterns to cool the building during the warm summer months while protecting from the cold, hard winter winds.
Thermal Mass on Southern Floor
Central Heating/Cooling System + Super Insulated Envelope By creating a central ventilation system that has complete control over the amount of outside air entering the home and creating a sealed barrier throughout the rest of the home the KHDWLQJ DQG FRROLQJ HI¿FLHQF\ FDQ reach 80%. Rainwater collection system: A system where the rainwater and storm water runoff would be controlled through the building and vegetation and could possibly be routed and used through the plumbing of the home.
Green Roof To Collect Rainwater
Skylights to Bring in Light
PS 2.02
PROJECT SCOPE (19,5210(17$/ $1$/<6,6
ACTION UPTOWN: 2FILL
PROJECT SCOPE (19,5210(17$/ $1$/<6,6
ARC48_550
PS 2.03
Allegheny Allegheny General Hospital By Car: 9 mins Public Bus: 26 mins Bike: 20 mins Walk: 51 mins
Strip Distr Heinz Field By Car: 10 mins Public Bus: 27 mins Bike: 20 mins Walk: 52 mins
PNC Park By Car: 8 mins Public Bus: 20 mins Bike: 16 mins Walk: 40 mins
Downtown
H Civic Arena By Car: 4 mins Public Bus: 10 mins Bike: 10 mins Walk: 20 mins
Duquesne Univ. By Car: 2 mins Public Bus: 5 mins Bike: 5 mins Walk: 15 mins
UPMC Mercy By Car: 2 mins Public Bus: 4 mins Bike:3 mins Walk: 10mins
U
Duquesne Heights UPMC Southside By Car: 6 mins Public Bus: 15 mins Bike:13 mins Walk: 26mins
Allegheny
By Car: 9 mins Public Bus: 27 mins Bike: 29 mins Walk: 51 mins
PS 3.00
Duquesne Heights By Car: 11 mins Public Bus: 49 mins Bike: 31 mins Walk: 69mins PROJECT SCOPE 6,7( /2&$7,21
Downtown
By Car: 4 mins Public Bus: 8 mins Bike: 8 mins Walk: 25 mins
S
Strip District
By Car: 6 mins Public Bus: 27 min Bike: 15 mins Walk: 35 mins
UPMC Childrenâ&#x20AC;&#x2122;s Hospital By Car: 12 mins Public Bus: 34 mins Bike: 26 mins Walk: 66 mins
ACTION UPTOWN: 2FILL
rict
UPMC Shadyside By Car: 10 mins Public Bus: 17 mins Bike: 24 mins Walk: 53 mins CMU By Car: 9 mins Public Bus: 17 mins Bike: 16 mins Walk: 41 mins
Hill District UPMC Presbyterian By Car: 4 mins Public Bus: 8 mins Bike:10 mins Walk: 22mins
UPTOWN
U Pitt By Car: 7 mins Public Bus: 13 mins Bike: 12 mins Walk: 30 mins
Carlow University By Car: 4 mins Public Bus: 5 mins Bike: 6 mins Walk: 13 mins
Oakland
UPMC Magee Womens Hospital By Car: 4 mins Public Bus: 9 mins Bike:10 mins Walk: 19mins
ns
Hill District
By Car: 5 mins Public Bus: 13 mins Bike: 5 mins Walk: 14 mins
It is extremely important that the site we are working on is located in Uptown because we are targeting the demographic of young professionals that would be working at one of the Educational, Civis, and Health care insitutuions highlighted in the map. Not only are there many institutions hiring primarily young professionals in the area but these institutions are continuously growing. It is also important to note the accessibility of Uptown to many other busy regions of Pittsburgh. Making Uptown a highly desirable place to live for young professionals.
Southside
t
ARC48_550
Southside
By Car: 5 mins Public Bus: 16 mins Bike: 12 mins Walk: 22 mins
Oakland
By Car: 4 mins Public Bus: 9 mins Bike: 9 mins Walk: 19 mins PROJECT SCOPE 6,7( /2&$7,21
Key Education Civic Health Care
PS 3.01
ZONING REQUIREMENTS =RQLQJ ,QIRUPDWLRQ IRU 3LWWVEXUJK 5 $ + 6LQJOH 8QLW $WWDFKHG 5HVLGHQWLDO LQ D +LJK 'HQVLW\ $UHD
5 $ + 6LQJOH 8QLW $WWDFKHG 5HVLGHQWLDO 'LPHQVLRQV Min Lot Size 1,800 sf Min Lot Size Per Unit 750 sf Min Front Setback 15 ft. Min Rear Setback 15 ft. Min Exterior Side yard Setback 15 ft. Min Interior Side yard Setback 10 ft. Max Height 40 ft. (not to exceed 3 stories)
MA
X.
Code of Ordinances: City of Pittsburgh, Pennsylvania Ordinance 1XPEHU HQDFWHG
BU
ILD
IN
G
&XUUHQW =RQLQJ DQG &KDOOHQJHV EN
VE
LO
PE
Uptown is made up of high and medium density UHVLGHQWLDO PL[HG XVH FRPPHUFLDO DQG LQGXVWULDO properties. Mixed use and high density residential are allotted the most square feet. The main mixed use commercial zone runs along Fifth Avenue whereas the neighborhood industrial zone abuts the 2nd Avenue highway. /RW LV ORFDWHG LQ WKH 5 $ + ]RQH LQ EHWZHHQ WZR VLQJOH XQLW DWWDFKHG KRPHV Lot 157 lies on the south side of Forbes Avenue between Jumonville St and Seneca St, placing it ZLWKLQ WKH 5 $ + ]RQLQJ GLVWULFW +RZHYHU LW LV FORVH proximity with the NDI zoning district as well as the LNC district.
NDI
Zoning Setback from Propoerty Lines
$&&(6625< 86(6 $1' 6758&785(6 Dumpsters; )HQFHV ZDOOV DQG UHWDLQLQJ ZDOOV SURYLGHG WKDW WKH ¿ QLVKHG VLGH IDFHV DGMDFHQW SURSHUW\ Gardens; *DUDJHV XVHG H[FOXVLYHO\ IRU WKH SDUNLQJ RI QRQ FRPPHUFLDO DXWRPRELOHV &DUSRUWV DQG RII VWUHHW SDUNLQJ DUHDV; Gates and guard houses; Storm shelter and fallout shelters Home occupations, subject to § 912.05; Playhouses, patios, porches/decks, gazebos and incidental household storage buildings; Radio and television receiving antennas and support structures Swimming pools and other recreational and play facilities for the use of residents; Solar energy systems; Extensive Green Roofs as described in § 912.04.I; Intensive Green Roofs as described in § 912.04.J;
PS 4.00
PROJECT SCOPE =21,1* 5(48,5(0(176
Ordinance 15 of the Pittsburgh Code was adopted in May 21, 1979 and took into considerations the demographics and trends of the city at the time. Since then, the demographics have shifted to include much higher percentages of young working professionals. This along with a shift in social culture where more young people are working through their V DQG ZDLWLQJ WR KDYH D IDPLO\ KDYH PDGH VLQJOH IDPLO\ 5 $ + KRPHV OHVV GHVLUDEOH DQG VPDOOHU homes and apartments more desirable (R2 or RM) in the uptown region of Pittsburgh.
=RQLQJ 3URSRVDO :H SURSRVH D QHZ W\SRORJ\ RI KRXVH WKDW ZRXOG Âż OO YDFDQW ORWV LQ WKH 5 $ + DUHD RI XSWRZQ WKDW ZLOO EH desirable to young professionals in the area and prevent the vacant lots from turning into unkept VLGH ORWV 7KH )LOO W\SRORJ\ ZLOO SURYLGH D EHGURRP DSDUWPHQW LQ WKH Âż UVW Ă&#x20AC; RRU DQG D Ă&#x20AC; RRU EHGURRP KRPH RQ WKH VHFRQG DQG WKLUG Ă&#x20AC; RRUV By im[plementing this typology in the nei9ghborhood it would allow families to live in durable sustainable KRPHV DQG VXSSRUW WKHLU LQFRPH E\ UHQWLQJ WKH Âż UVW Ă&#x20AC; RRU DSDUWPHQW 2XU W\SRORJ\ ZLOO KDYH WR JR WKURXJK a process of either receiving a zoning variance SHUPLW RU D SURFHVV WR FKDQJH SDUWV RI WKH 5 $ + ]RQH LQWR D 5 + RU 50 + LQ RUGHU WR LPSOHPHQW WKH 2Fill houses.
RP
RP
RP
P
RM-M
ACTION UPTOWN: 2FILL
ARC48_550
R2-VH LNC R1A-H
R1A-H NDI
Map Key: Residential
NDI
H
Code
Planned Development
R1A-H, RM-M, R2-VH RP
Mixed Use/Industrial
LNC
Industrial
NDI
Parks
P
Hillside
H
2Fill Site Vacant Lots Major Roads
1HLJKERULQJ =RQHV 7KH 5 $ + ]RQH WKDW ORW LV ORFDWHG ZLWKLQ LV DOVR QHLJKERULQJ two different zones, LNC on the north side and NDI ont he south side. LNC is intended to promote local commercial development KDQG LQ KDQG ZLWK UHVLGHQWLDO KRXVLQJ 7KRXJK WKHUH LVQÂśW D JUHDW amount of commerical activity in this zone it could increase in the future with the help of project like those of action housing. Zone NDI promotes more industrial commercial uses than the LNC district but the trends throughout Pittsburgh demonstrate that imposing industrial programs will not be placed within this zoning UHJLRQ 7KH IDFW WKDW WKH 5 $ + ]RQH LV QHLJKERULQJ ERWK /1& DQG NDI districts will be a great asset in the future to lot 157 and the neighborhood as a whole.
902.01.A.1 - Residential Zoning Districts 5HVLGHQWLDO =RQLQJ 'LVWULFWV DUH IRUPHG E\ FRPELQLQJ D 8VH 6XEGLVWULFW ZLWK D 'HYHORSPHQW 6XEGLVWULFW USE: R1A, Single-Unit Attached Residential DEVELOPMENT: H - High-Density 904.02.A - Purpose 7KH /1& /RFDO 1HLJKERUKRRG &RPPHUFLDO 'LVWULFW LV intended to: 1. Maintain the small scale and rich diversity of neighborhoodVHUYLQJ FRPPHUFLDO GLVWULFWV 2. Promote and enhance the quality of life in adjacent residential DUHDV 3. Reduce the adverse impacts that are sometimes associated with commercial uses in order to promote compatibility with residential development. 904.03.A - Purpose 7KH 1', 1HLJKERUKRRG ,QGXVWULDO 'LVWULFW LV LQWHQGHG WR 1. Allow a broad range of industrial uses, subject to performance VWDQGDUGV $FFRPPRGDWH RWKHU XVHV WKDW DUH FRPSDWLEOH ZLWK RIÂż FH FRPPHUFLDO DQG UHVLGHQWLDO ODQG XVHV 3. Encourage development patterns that include a mix of housing, employment and shopping opportunities. PROJECT SCOPE =21,1* 5(48,5(0(176
PS 4.01
TYPOL
LOGIES
SITE UTILIZATION Site Facts FORBES AVENUE
SIDEWALK
B.3.>.x
B.3.>.x
F.
B.3.>.x
B.3.>.*
B.3.>.x
B.3.>.x B.3.>.x
/RW 'HSWK Âś ´ Parkign Space Depth: 22â&#x20AC;&#x2122; *DUGHQ 'HSWK Âś ´ /RW :,GWK Âś ´ Front Setback: 22â&#x20AC;&#x2122; Rear Setback: 10â&#x20AC;&#x2122; East Setback: N/A West Setback: N/A
FORBES AVENUE FORBES AVENUE
SIDEWALK
SIDEWALK
B.3.>.x
B.3.>.xB.3.>.xB.3.>.xB.3.>.x F. B.3.>.xB.3.>.* F. B.3.>.x B.3.>.* B.3.>.x B.B.3.>.x 3.>.x B.3.>.x B.3.>.x
SIDEWALK
B.3.>.+ B.3.>.+
B.3.>.*
B.3.>+*
Tustin Street STREET FRONT SETBACK & UTILIZATION CHARACTERISTICS A. Front setback less than 10 feet B. No front setback C. Community Garden D. Empty Lot, uncared for E. Any front setback for yard use F. Infill site, used as a side lot
% 3.>.+ % 3.>.x
B.3.>.+ B.3.>.+
1. One floor building 2. Two Floor building 3. Three Floor Building Side lot entrance and back porch Community garden Side lot entrance
% 3.>.+
B.3.>.+ B.3.>.+
<. Street level entrance >. Elevated entrance -. Entrance through side Parking Spaces
F
*. Stand alone house +. Semi - attached x. Attached Overgrown green uncared for Lot 157 boundary
% 3.>.+ % 3.>.x
Houseâ&#x20AC;&#x2122;s back gardens
% 3.>.x
SIDEWALK
SIDEWALK B.3.>.*
Tustin Street
Tustin Street
The buildings along Forbes Avenue, between Seneca Street and Jumonville Street are similar in appearance, height, way they mediate with the street, and relation to their adjacent buildings. This similarity creates a sense of continuity along the street. Lot 157, breaks this continuity because it is an empty lot in middle of this continuous urban fabric. Lot 157â&#x20AC;&#x2122;s use as a side lot, garden, and SDUNLQJ ORW EUHDNV ZLWK WKH HQWLUH Ă&#x20AC; RZ of the street: it is a missing tooth along the block.
% 3.>.x % 3.>.x % 3.>.x
B.3.>.*B.3.>+*
B.3.>+*
STREET FRONT SETBACK STREET FRONT & UTILIZATION SETBACKCHARACTERISTICS & UTILIZATION CHARACTERISTICS A. Front setback less A.than Front 10setback feet less 1. than One 10 floor feet building1. One floor <. Street building level entrance <. Street*.level entrance Stand alone house*. Stand alone house B. No front setback B. No front setback 2. Two Floor building2. Two Floor >. Elevated buildingentrance>. Elevated entrance +. Semi - attached +. Semi - attached C. Community Garden C. Community Garden 3. Three Floor Building 3. Three-.Floor Entrance Building through side -. Entrance through side x. Attached x. Attached Parking Spaces Parking Overgrown Spaces green Overgrown green D. Empty Lot, uncared D. Empty for Lot, uncared forSide lot entrance Side lot entrance and use back porch and back porch uncared for uncared for E. Any front setbackE. forAny yard front usesetback for yard Houseâ&#x20AC;&#x2122;s back Houseâ&#x20AC;&#x2122;s back Community F. Infill site, used as F. a side Infill lot site, used as a sideCommunity lot Lot 157 boundary Lot 157 boundary gardens garden garden gardens Side lot entrance Side lot entrance Wooden Fence
PS 5.00
PROJECT SCOPE 6,7( 87,/,=$7,21
ACTION UPTOWN: 2FILL
ARC48_550
7KH FXUUHQW RZQHUV RI /RW XVH WKLV VSDFH DV D EDFN\DUG DQG SDUNLQJ IRU WZR FDUV $Q\ LQWHUYHQWLRQ 8SWRZQ GRHV ZLOO QHHG WR Âż QDQFLDOO\ LQFHQWLYL]H WKH FXUUHQW RZQHUV WR JLYH XS WKLV VSDFH IRU SHUVRQDO XVH $ SRVVLELOLW\ LV WR FUHDWH D WZR XQLW KRXVH ZKHUH WKH RQH RQ WKH Âż UVW Ă&#x20AC; RRU is a rental unit that will bring in a steady stream of income while the other unit can be sold. The rental unit will help subside the construction and help the owners get more favorable mortgage agreement with the bank.
6HWEDFNV 8WLOL]DWLRQ
The site has been repurposed by the owners of the adjacent property. The front part is now used to park two cars while the back is a garden with a small shed. A chain fence separates the parking and garden while a wooden fence wraps DURXQG WKH EDFN RI WKH SURSHUW\ 7KH VWUHHW LV FRPSRVHG RI VHPL GHWDFKHG URZ houses that share common dividing walls. However, a few properties have a VOLJKW VLGH VHWEDFN RI Âś WKDW VHUYHV DV D QDUURZ DOOH\ZD\ FRQQHFWLQJ WR WKH backyard. There are no side setback requirements in this zoning.
Connection to Community Garden
The community garden for the Uptown neighborhood is directly behind Lot 157. 7KLV LV D JUHDW EHQHÂż W IRU RXU VLWH DQG FDQ LPSURYH WKH UHVLGHQWVÂś TXDOLW\ RI OLIH substantially. At the moment, there is a dilapidated wooden fence that separates /RW IURP WKH FRPPXQLW\ JDUGHQ 7KH FRPPXQLW\ JDUGHQ LV Ă&#x20AC; DQNHG RQ RQH side by a neighboring houseâ&#x20AC;&#x2122;s backyard and on the other by a piece of land. Even though the community garden appears slightly unkept, this can change if we provide the future residents of Lot 157 an entry to the community garden. If the community garden it reactivated in the future and the abandoned adjacent lots rehabilitated a larger community space centered around nature could be created. We are going to integrate our intervention with the community garden to enhance the feeling that residents are surrounded by green space. By integrating our landscape with the community garden, a more vibrant and far reaching intervention will emerge. PROJECT SCOPE 6,7( 87,/,=$7,21
PS 5.01
COST FACTORS: PROJECT SCOPE Site Conditions Access WR WKH VLWH LV Ă&#x20AC;DQNHG RQ WZR RI LWV VLGHV E\ H[LVWLQJ KRXVHV DQG WR WKH EDFN E\ WKH FRPPXQLW\ JDUGHQ 7KHUHIRUH DFFHVV LV EH FRPSOLFDWHG raising construction costs. We suggest to use Forbes Avenue for fast deliveries and negotiate a deal with the neighborhood to use the community garden for access during construction, and to restore the garden at the projectâ&#x20AC;&#x2122;s completion. Storage on site is limited and few materials can be stored there at any given time. This will require additional careful planning regarding when materials are brought to site. Another empty lot in Uptown can be used as a provisional storage location. Ideally a shed would be built on part of the community garden because of its proximity to the site reducing handling costs from the storage location to the site. Utilities: The Water and Sewage Authority in Pittsburgh requires new constructions to separate their stormwater and sewage pipes to the cityâ&#x20AC;&#x2122;s main line. This will raise plumbing costs, but is a sustainable environmental need. Neighbors: Noise control measures will need to be implemented to reduce disturbance to neighbors and other community residents. Waste Disposal: Waste will need to be quickly hauled outside the site because of limited space and not to bother any neighbors.
/RFDWLRQ Labor Rates are comparable to the national average according to RSMeans Assembly Data. Using an open shop labor type will be less expensive than using a standard union labor force. We recommend this approach with the condition that there be a strong performance bond. Material Availability should not pose any complications or problems. The materials used are common in construction and do not need to be customized. Political Stability: No problems related to this. Economic Stability: Pittsburghâ&#x20AC;&#x2122;s economy is more stable to comparable Rustbelt ities.
5HODWLYH 'HVLJQ ,VVXHV Complexity of Design: The design will focus on reducing construction costs to make the house as affordable as possible. Size of Design Team: WKH GHVLJQ WHDP LV FRPSULVHG RI ÂżYH VWXGHQWV SXUVXLQJ D %HFKHORUÂśV RI $UFKLWHFWXUH GHJUHH DW &DUQHJLH 0HOORQ 8QLYHUVLW\ â&#x20AC;&#x2DC;s school of Architecture. Pay Rates for Design Team: 7KHUH LV D GHVLJQ IHH EDVHG RQ HVWLPDWHG SURMHFW FRVW $ FRQWLQJHQF\ ZLOO EH VHW DVLGH GXULQJ WKH SUH GHVLJQ SKDVH WKH FRQWLQJHQF\ ZLOO GHFUHDVH DV WKH SURMHFW SURJUHVVHV ÂżQDOO\ UHDFKLQJ GXULQJ WKH SUH ELG HVWLPDWH SKDVH
Performance Criteria Quality of Work: The highest quality of work regarding design, construction, and systems integration will be required by all parties involved. This will raise the cost of the project, but will ensure quality and durability. Category of Building: 5HVLGHQWLDO DWWDFKHG PXOWL IDPLO\ ZLWK WKH JURXQG Ă&#x20AC;RRU set aside as an income producing rental property. Passive Systems: Emphasis will be placed to maximize the use of natural light, heat, and ventilation. Good design can achieve this without raising the costs. Utility Bills: Reduce the utility bill for future residents in accordance to Action Housingâ&#x20AC;&#x2122;s mission. Insulation installation costs will increase, but th e initial investment will be recovered over time through the utility cost savings.
'HOLYHU\ 0HWKRGV 7\SH RI &RQWUDFW 'HVLJQ %LG %XLOG Payment Method: Lump Sum Bonds required: Bidding bond, performance bond, payment bonds wil be required by the main contractor.
PS 5.02
PROJECT SCOPE &267 )$&7256
SITE DEVIATION UTILIZATION
ACTION UPTOWN: 2FILL
ARC48_550
The site utilization for House 1 demonstrates many infringements on the zoning code. The house does not respect the rear setback of 15â&#x20AC;&#x2122;, by 4â&#x20AC;&#x2122;. The owners of the house also built a wooden staircase leading to a back porch that is directly on our site. A wooden fence has been erected on WKH EDFN RI RXU VLWH \HW LW GRHV QRW IROORZ WKH SURSHUW\ ERXQGDU\ OLQHV GLPLQLVKLQJ WKH ORW VL]H VLJQLÂż FDQWO\ (YHQ WKRXJK RXU ORW LV FXUUHQWO\ RZQHG by the same owner of House 1 and it is expected for the owner to help develop the new house, the deviations from code will have to be mediated. House 1 already has a main entrance facing Forbes Avenue so we do not expect any problem removing the side entrance on the chain fence. The steps leading up to the back porch will have to be removed and shifted to the northern side. The primary challenge will be to convince the QHLJKERUV WKDW LW LV EHQHÂż FLDO WR UHPRYH WKH SDUNLQJ VSDFHV IURP WKH IURQW RI WKH SURSHUW\ +RZHYHU WKHUH LV DYLODEOH VWUHHW SDUNLQJ WR DFFRPRGDWH WKHLU FDUV (YHQ WKRXJK WKH RZQHUV ZLOO KDYH WR JLYH XS VRPH RI WKH EHQHÂż WV DQG DPHQLWLHV IURP XVLQJ /RW DV D VLGH ORW WKH HFRQRPLF EHQHÂż WV of developing it will outweigh the losses. On the other hand the site deviation analysis for House 2 demonstrates that it complies with all of the zoning requirements. This house does not encroach or use any space on Lot 157. 6LQFH RXU LQWHUYHQWLRQ LV PHDQW WR VHUYH DV D PRGHO IRU D QHZ KRXVLQJ W\SRORJ\ IRU LQÂż OO ORWV WKHUH ZLOO EH VSHFLÂż F VLWH GHYLDWLRQV LQ HDFK VLWH 7KH NH\ WR VXFFHVV LQ UHGHYHORSLQJ HDFK ORW LV WR ZRUN ZLWK WKH QHLJKERUV FRPSURPLVH DQG PDNH LW HFRQRPLFDOO\ EHQHÂż FLDO IRU WKH QHLJKERUV DQG community.
Site Deviation 1
Site Deviation 2
PROJECT SCOPE 6,7( '(9,$7,21 87,/,=$7,21
PS 6.00
Site Condition The project site 2026 Forbes Ave presents four distinct conditions that would effect the construction process on the site. While there are solutions to these conditions, it would either lead to greater construction cost, or longer construction time.
Condition 1: Construction Noise and Safety
Site Elements
3
5
4
Condition: Adjacent buildings are residences and at least one of them are occupied, leading to construction noise concerns. There is very little maneuvering space on site and the neighboring buildings are within immediate proximity to the new construction. Solution: Limit the construction activity to weekdays and daytime and implement noise control measures to reduce construction noise. All construction personnel and everyone entering the construction site must be fully aware of the safety consideration. Precautions must be taken not to damage neighboring buildings and structures, including construction of scaffolding to protect it. Affects: Construction Time and Cost
Site 5
Condition 2: Construction Access
Site Elements
1
4
6
7
Condition: +HDY\ WUDIÂż F RQ )RUEHV $YH ORZ KDQJLQJ SRZHUOLQHV DQG ODFN RI maneuvering space on site makes it hard for heavy equipments and trucks to enter the site. Solution: Lease out the community garden lot behind the site for the duration of the construction.
1
Affects: Construction Cost
Key 1 Forbes Avenue
5
Neighboring Buildings
2
Sewage Pipe
6
Community Garden
3
Fire Hydrant
7
Tustin St
4
Powerline
PS 7.00
PROJECT SCOPE 6,7( &21',7,21
Fo
3
4
rbe
sA ve 2
ACTION UPTOWN: 2FILL
ARC48_550
Condition 3: Waste Disposal
Site Elements
1
5
6
7
Condition: Site lacks space for material and waste dropoff/pickup and storage. Solution: Lease the community garden from the City of Pittsburgh and remove the planting for the duration of construction. Replant the landscape after the construction. Additional shed structure might be required to protect construction materials from weather damage. Waste must be quickly picked up from site to reduce environmental damage and maintain a clean street. Construction Cost Affects:
7T
ust
6
in S
t
Community Garden
&RQGLWLRQ 3RZHU DQG 6HZDJH &RQQHFWLRQ
Site Elements
1
2
4
Condition: PWSA requires new constructions to separate stormwater and sewage pipes to the main sewage lines. Additionally PWSA charges an undeterminable amount for new connections to the main power and sewage line. Solution: Sewage separation must be designed into the building construction. New power and sewage connection cost must be considered for the budget. Affects: Construction Cost
PROJECT SCOPE 6,7( &21',7,21
PS 7.01
Materials and Construction 2030 Forbes Ave
2028 Forbes Ave
Proposed Material
2024 Forbes Ave 2022 Forbes Ave
2026 Forbes Ave
Roof On buildings where the roof is visible from the street level, asphalt VKLQJOHV LV WJH PRVW FRPPRQ URR¿ QJ PDWHULDO 7KH SURSRVHG PDWHULDO follows this pattern by using asphalt shingle but in different shape and size from other buildings.
Wall The area around the project site uses masonry as the main exterior and structural material. Our proposed material of brick and hardwood siding for the wall and is carefully chosen to complement the horizontality expressed in existing materials.
Foundation 7KH KHLJKW GLIIHUHQFH EHWZHHQ WKH ¿ UVW À RRU DQG VORSH RI WKH )RUEHV Avenue exposes some of the basement construction. The material that is around the site is stone or CMU blocks most common compliment the masonry construction. In line with the modernity of the project concrete was chosen as foundation material.
PS 8.00
PROJECT SCOPE 0$7(5,$/6 $1' &216758&7,21
The construction and materials seen around the project site are similar to each other as they were originally constructed around the same time as worker’s housing. As a new construction in this neighborhood, materials had to be carefully selected.
ACTION UPTOWN: 2FILL
2030 Forbes Ave
2028 Forbes Ave
Proposed Material
ARC48_550
2024 Forbes Ave 2022 Forbes Ave
2026 Forbes Ave
Dormer The dormers have windows on them and the roof of the dormers is usually gabled. A single dormer window is proposed for the project, but has been redesigned to complement the modern design of the proejct.
:LQGRZ 0RVW RI WKH ZLQGRZ FRQ多 JXUDWLRQV DURXQG WKH SURMHFW VLWH DUH double hung windows that are taller than wide. The project also uses double hung windows with a similar proportion.
Door Most of the doors around the site are wooden windows with either decorations or fenestrations. Similarly, the proposed material for the door is wood, which complements the brick and hardwood siding proposed for the wall material.
PROJECT SCOPE 0$7(5,$/6 $1' &216758&7,21
PS 8.01
HEATING EFFICIENCY STRATEGIES
4
STRUCTURAL INVESTMENTS THAT WILL LOWER THE HEATING AND COOLING
BILLS.
COMFORTABLE
THE
RESIDENTS
TEMPERATURE
WILL
WITHOUT
ENJOY
A
BREAKING
CONSISTENTLY THE
BANK.
,QQH¿ FLHQFLHV LQ ([LVWLQJ +RPHV 7KH KRXVHV LQ WKH DUHD ZHUH FRQVWUXFWHG LQ WKH HDUO\ ¶V DQG WKH LQVXODWLRQ RI ZDOOV URRIV DQG Ã&#x20AC; RRUV DOORZ IRU WKH KHDW WR OHDN WKURXJK DQG the cold to seep into the rooms. The windows in the existing homes also allow for a high transfer of heat from the interior to the cold exterior air through a thin single pane of glass as well as the wooden window frames.
Proposed Systems ,Q RUGHU WR ORZHU WKH KHDWLQJ DQG FRROLQJ ELOOV VLJQL¿ FDQWO\ IRU WKH IDPLOLHV OLYLQJ ZLWKLQ WKH KRPH ZH SURSRVH D KLJKO\ LQVXODWHG EXLOGLQJ H[WHULRU 7KLV LQFOXGHV KLJKO\ LQVXODWHG URRI VWUXFWXUH ZDOOV DQG Ã&#x20AC; RRU SODWH :LQGRZV LQ RUGHU WR SURYLGH VXQOLJKW ZKLOH DOVR PLQLPL]LQJ KHDW ORVV ZLOO EH GXDO SDQHG DQG HI¿ FLHQWO\ SODFHG DORQJ WKH IDFDGH WR DOORZ IRU PD[LPXP GD\OLJKW ZLWKLQ WKH VSDFHV ZLWK D VPDOOHU ZLQGRZ DUHD
Winter Heating Diagram
10O F 60O F 65O F 70O F 50O F
PS 9.00
PROJECT SCOPE HEATING EFFICIENCy STRATEGIES
ACTION UPTOWN: 2FILL
1
:(// ,168/$7(' 522)
2
'28%/( 3$1( 9,1</ :,1'2:6
ARC48_550
Though the roof is not visible from the street and the resident will not think about it on a regular basis, it is extremely important when it comes to keeping the home at a comfortable temperature and the utility bills low. As heat naturally rises, all the heat generated throughout the home will rise as well. This means that once the heat reaches the roof in the winter, where the roof is directly exposed to the frigid temperatures of Pittsburgh winters, it has the potential to transfer all of that heat to the outside. To prevent this loss of heat, the roof must be insulated very well to an R value of 24. The roof is 12 inches thick, consisting of a thick SIP panel, gypsum interior Âż QLVK DQG H[WHULRU DVSKDOW VKLQJOHV
The windows need to effectively serve a couple of purposes. In the summer, they must be easily operable to allow for cross breezes through the house. This will decrease the cost of air conditioning. Secondly, they must seal the cold out as thoroughly as possible during the winter. It has to do this in 2 ways: 1: The double pane of the window affords a higher R value to the window insulating from the cold more effectively. The windowâ&#x20AC;&#x2122;s double SDQH FUHDWH DQ DLU WLJKW DLUVSDFH EHWZHHQ WKHP WKDW VORZV GRZQ WKH WUDQVIHU RI KHDW WKURXJK WKH JODVV 7KH ZLQGRZ IUDPH PXVW Âż W WLJKWO\ LQWR LWV IUDPH DQG WKH YLQ\O PDWHULDO PXVW SUHYHQW KHDW IURP WUDQVIHULQJ WKURXJK WKH PDWHULDO 9LQ\O transfers heat slower than both wood and metal.
3
+,*+/< ,168/$7(' (;7(5,25 :$//6 The exterior walls of the building have the largest surface area exposed to the summer sun and the cold winter temperature and winds. Therefore, they have to protect the interior temperature from the exterior conditions. By using SIP panels, the insulation is combined LQWR WKH VWUXFWXUDO VXSSRUW RI WKH KRPH 7KH 6,3 SDQHOV KDYH DQ LQVXODWLRQ YDOXH RI 5 &RPELQHG ZLWK WKH H[WHULRU Âż QLVK J\SVXP ZDWHU YDSRU EDUULHUV DQG WKH LQWHULRU Âż QLVKHV WKH UHVXODWLQJ 5 YDOXH LV 0RVW KRPHV LQ WKH DUHD KDYH ZDOOV ZLWK DQ 5 YDOXH RI DERXW ZKLFK LV ZK\ WKH\ FDQ EH GLIÂż FXOW WR NHHS KHDWHG PDNLQJ WKH XWLOLW\ ELOOV LQ WKH ZLQWHU FDQ EH YHU\ H[SHQVLYH
4
+,*+/< ,168/$7(' )/225 3/$7( ,W LV LPSRUWDQW WR KDYH D KLJK LQVXODWLRQ YDOXH RQ WKH Ă&#x20AC; RRU EHWZHHQ WKH Âż UVW Ă&#x20AC; RRU DQG EDVHPHQW EHFDXVH WKH EDVHPHQW ZLOO EH XQKHDWHG 7KH EDVHPHQW ZLOO RQO\ FRQWDLQ WKH ZDVKHU DQG GU\HU WR EH VKDUHG E\ ERWK WKH KRXVLQJ XQLWV 7KH LQVXODWLRQ YDOXH RI WKH Ă&#x20AC; RRU SODWH LV 7KH 6,3 VWUXFWXUH FRPELQHG ZLWK WKH ZRRG MRLVWV DQG Âż QLVKHG FRPELQHG DUH ZKDW DIIRUG WKH 5 YDOXH
PROJECT SCOPE HEATING EFFICIENCy STRATEGIES
PS 9.01
HOME ENERGY COMSUMPTION %8,/',1* 3(5)250$1&( )$&7256
(1(5*< 86( ,17(16,7<
Average Lighting Power
0.44 W / ft2
Electricity EUI
7 kWh / sf / yr
Electrical Cost
$0.13 / kWh
Fuel EUI
47 kBtu / sf / yr
Fuel Cost
$1.26 / Therm
Total EUI
71 kBtu / sf / yr
8VLQJ WKH $XWRGHVN HQHUJ\ FRQVXPSWLRQ FDOFXODWLRQ VRIWZDUH ZH DUH DEOH WR TXDQWLWDWLYHO\ DQDO\]H WKH HI多 FLHQF\ RI WKH KRXVH Using these estimations derived from the program, we can make critical design decisions such as the construction and insulation properties of the roof and the walls.
$118$/ (1(5*< 86( &267
34% 66%
$118$/ (1(5*< &267 Electricity
34%
$3,357
25,279
Fuel
66%
$2,129
1,691
kWh Therms
The majority of the costs expended by the residents of the home will be due to fuel rather than electricity. Fuel is a result of the heating system and some water heating.
$5,486
0217+/< +($7,1* $1' &22/,1* /2$' mBtu 15 10 5 0 Jan Feb Mar Apr May Jun Jul
Aug Sep Oct Nov Dec
Heating load Cooling load
PS 9.02
PROJECT SCOPE +20( (1(5*< &2168037,21
When the heating and cooling load is greater than zero energy is being gained and when the load is less than zero energy is being lost, meaning the temperature decreases. From the chart it is evident that in the winter months the house loses heat and in the summer months more energy is needed to cool the home.
ACTION UPTOWN: 2FILL
ARC48_550
5(1(:$%/( (1(5*< 327(17,$/
/,)( &<&/( (1(5*< 86( &267 Life Cycle Electricity Use
758,385 kWh
5RRI 0RXQWHG 39 6\VWHP /RZ (IÂż FLHQF\
Life Cycle Fuel Use
50,742 Therms
5RRI 0RXQWHG 39 6\VWHP 0HGLXP (IÂż FLHQF\ 35,558 kWh / yr
Life Cycle Energy Cost
$74,717
5RRI 0RXQWHG 39 6\VWHP +LJK (IÂż FLHQF\
53,336 kWh / yr
Single 15â&#x20AC;&#x2122; Wind Turbine Potential
928 kWh / yr
<HDU OLGH DQG GLVFRXQW UDWH IRU FRVWV
17,779 kWh / yr
39 HIÂż FLHQFLHV DUH DVVXPHG WR EH DQG IRU ORZ PHGLXP DQG KLJK HIÂż HQF\ V\VWHPV
(1(5*< 86( )8(/
10% 90%
Therms HVAC
90%
$1,931
1,534
Domestic Hot Water
10%
$195
155
$2,127
1,590
(1(5*< 86( )8(/ The majority of the costs incurred due to fuel consumption are due to the heating of the home (HVAC). Pittsburgh is a cold climate and the fuel consumption in the winter increases dramatically. It is critical that we insulate the home to impact the cost of heating.
(1(5*< 86( (/(&75,&,7< 20% 28%
52%
(1(5*< 86( (/(&75,&,7< kWh HVAC
52%
$1,746
13,152
Lighting
20%
$571
5,055
Misc. Equipment
28%
$939
7,070
$3,356
25,277
Cooling in the summer will impact the electricity consumption It LV LPSRUWDQW WR FRQVLGHU WKH SRVVLEO\ EHQHÂż WV RI QDWXUDO FURVV ventilation in the design of the home, minimizing the need for air conditioners in the hot summer months.
PROJECT SCOPE +20( (1(5*< &2168037,21
PS 9.03
INFILL LOT AS A TYPLOGY
Fifth A
Vacancy Plots around Uptown
The Uptown area currently has 18 vacant lots, including the project site. Excluding the project site, 2026 Forbes Ave, there are 4 vacant lots that could be developed like the project. Out of the 4 vacant lots that is similar to the project site, one lot, 2002 Tustin St, has a very real chance that it will be developed into a side lot by the owner who owns and lives next to it.
Parcel ID: Mailing Address: Current Condition: Lot Area: 2012 Assessed Value: Owner: Owner Residence:
11K141A 2007 TUSTIN ST VACANT 504 sq ft. $1,400 REMEDIOS THOMPSON PENN HILLS
Parcel ID: Mailing Address: Current Condition: Lot Area: 2012 Assessed Value: Owner: Owner Residence:
11K140-6 2003 TUSTIN ST VACANT 519 sq ft. $900 KELLY RAYMOND UPTOWN
Watson
Parcel ID: Mailing Address: Current Condition: Lot Area: 2012 Assessed Value: Owner: Owner Residence:
PS 10.00
Jumonville S
t
12
17 16 15
11K271 2002 TUSTIN ST VACANT 675 sq ft. $3,600 GEORGE FULKS UPTOWN
PROJECT SCOPE 7<32/2*< &$6( 678'<
Forbes A
2 1 3
11 Tustin St
ACTION UPTOWN: 2FILL
Ave
Parcel ID: Mailing Address: Current Condition: Lot Area: 2012 Assessed Value: Owner:
4 14 13
Project Site
Parcel ID: Mailing Address: Current Condition: Lot Area: 2012 Assessed Value: Owner: Owner Residence:
5 6 7 8 9 Vacancy Plots around Uptown Department of City Planning, Pittsburgh GIS http://www.pittsburghpa.gov based on Census 2010
11K157 2026 FORBES AVE VACANT 1,463 sq ft. $1,300 JAMES ARDELLA UPTOWN
Mailing Address
Current Condition
Lot Area (sq ft)
2012 Assessed Value
5 11K163
2034 FORBES AVE
VACANT
1320
$1,200
6 11K164
2036 FORBES AVE
VACANT
1303
$1,200
7 11K165
2038 FORBES AVE
VACANT
1243
$1,200
8 11K167
2040 FORBES AVE
VACANT
660
$5,800*
Seneca St
Parcel ID
Ave
110
11K28 2022 FIFTH AVE VACANT 2,640 sq ft. $1,700 DAVIS JOSEPHUS & BERTHA HARRIS UPTOWN
Owner Residence:
n St
ARC48_550
9 11K162A
TUSTIN ST
VACANT
960
$1,000
10 11K155
2027 TUSTIN ST
VACANT
1044
$1,000
11 11K152
2025 TUSTIN ST
VACANT
840
$1,000
12 11K99
2018 WATSON ST
VACANT
2640
$1,700
13 11K36
2038 FIFTH AVE
VACANT
5760
$9,500*
14 11K34
2036 FIFTH AVE
VACANT
3960
$8,600*
15 11K25
2016 FIFTH AVE
MUNICIPAL GOV’T
2640
$4,000*
16 11K24
2014 FIFTH AVE
VACANT
2640
$8,600*
17 11K23
2012 FIFTH AVE
VACANT
2640
$3,900*
Value and Owner information from Allegheny County Assessment Website http://www2.county.allegheny.pa.us/RealEstate/Search.aspx Accessed September 2012
PROJECT SCOPE 7<32/2*< &$6( 678'<
PS 10.01
INFILL LOT TYPLOGY 2026 Forbes Avenue
Tustin St Community Garden Tustin St Community Garden
This is the original lot that will be used as a prototype to EH DSSOLHG WR WKH UHVW RI WKH LQÂż OO ORWV LQ WKH QHLJKERUKRRG The lot is in between two houses: to the front it faces Forbes Avenue which and in its rear lies a community garden. The front end of the lot lies along a row of houses that have a continuous façade with the exception of our LQÂż OO ORW ZKLOH WKH EDFN RI WKH VLWH RSHQV WR D VFHQDULR LV VLPLODU WR PDQ\ RI WKH RWKHU LQÂż OO ORWV LQ WKH QHLJKERUKRRG the facade facing the main road is more formal and has WR Âż W LQWR WKH FRQWLQXRXV XUEDQ IDEULF ZKLOH WKHLU EDFNV DUH PRUH Ă&#x20AC; H[LEOH
2003 and 2007 Tustin Street
Jumoville St
Jumoville St Private Garden Side alley Private Garden Back yard 7KHUH DUH WZR LQÂż OO ORWV VHSDUDWHG E\ RQH KRXVH RQ WKLV Side alley Tustin 2003 Back yard Tustin 2007 Tustin 2003 Tustin St
PS 10.02
PROJECT SCOPE 7<32/2*< &$6( 678'<
Tustin 2007 Tustin St
location. The sense of discontinuity is enhanced because of the additional missing houses. In this scenario, the RULJLQDO W\SRORJ\ FRXOG EH DSSOLHG WR ERWK LQÂż OO ORWV 7KH site conditions are very similar since they have a large open space in the back as well. Reactivating these two LQÂż OO ORWV ZRXOG UHYLWDOL]H WKH VWUHHW DQG FUHDWH D VHQVH RI continuity throughout.
ACTION UPTOWN: 2FILL
ARC48_550
2003 Tustin Street
Internal Back yard Side Alley Back yard facing street
This lot if fronted by a main road on its primary facade, and a narrow side alley on its back. This will require the LQ多 OO SURWRW\SH WR EH VOLJKWO\ DGDSWHG WR WKLV VLWH WR SURYLGH more privacy to the back side from passersby. With the one exception, the site has similar conditions to the original, 2026 Forbes Avenue, so the prototype can be easily implemented.
Jumoville St Tustin 2003 Tustin St.
Forbes Avenue 2022
Backyard
Backyard
Tustin St.
Side Entrance
Forbes Avenue
This lot has two major streets on both ends, Forbes Avenue and Tustin Street. The surrounding houses treat Forbes as the principal street where the facades have a more standardized and continuous treatment, while the side towards Tustin is used as a backyard surrounded by a fence. 7KH RULJLQDO LQ多 OO W\SRORJ\ SURWRW\SH FRXOG EH LPSOHPHQWHG LQ this site as well.
PROJECT SCOPE 7<32/2*< &$6( 678'<
PS 10.03
MANSARD ROOF TYPOLOGY STUDY TyPE 81,76
F
A fairly consistent housing type. Homes that DUH 7\SH ) KDYH ÀDW URRIV and are generally two stories high and two bays wide.
PF
TyPE 81,76
Peak roofed homes that have been PRGL¿HG WR KDYH D ÀDW roof in the rear of the home.
P
TyPE 81,76
Each has two stories and a ¿QLVKHG DWWLF ZLWK D SHDNHG roof. Many have dormer windows in front; while some have them in the back.
M
TyPE 81,76
A strong typology that is fairly unique to the community of Uptown, 2Fill chooses to appropriate some features of Type M while giving them a modern twist. It also takes into account the other common typological features, such as small porch steps on the sidewalk, vertically oriented windows as a metered datum, and the common dormer windows.
Type M occurs in a variety of building widths, but they are consistently three stories high and have mansard roofs with dormer windows. TyPE 81,76
Mansard Roof
NR
1RQ UHVLGHQWLDO EXLOGLQJV There are two garages and two sheds.
Dormer Window Peaked Roof Flat Roof
The houses in Uptown, whether detached or row houses, are almost all a variation on one typical type. The basic portion of each house is a cuboid made up of two stories. There is then a third story WKDW LV HLWKHU D IXOO VWRU\ ZLWK D ÀDW URRI D SHDNHG roof, likely with dormer windows; or a mansard roof with dormer windows. For houses sited on a slope, the entrances are above street level, requiring a stoop. Stoops are either perpendicular to the home and street, or have a small porch with steps leading off parallel to the street. Details (not depicted) that vary are lintels and cornices.
PS 10.03
PROJECT SCOPE 7<32/2*< &$6( 678'<
Window
Stoop Porch and Steps
ACTION UPTOWN: 2FILL
ARC48_550
We studied the buildings along Forbes Avenue between Seneca Street and Jumoville Street that have mansard roofs. We decided to study this building typology because it is repeated throughout the neighborhood creating a sense of continuity in the urban fabric and cohesiveness between individual buildings. All the buildings with a mansard roof are three levels, have street parking are 24 feet wide, and have a small private garden. :H DUH UHODWLQJ WKLV LQIRUPDWLRQ EDFN WR RXU VLWH EHFDXVH RXU LQWHUYHQWLRQ ZLOO GLUHFWO\ UHODWH WR LWV FRQWH[W DQG HQVXUH WKH EXLOGLQJ 多WV LQ ZLWK LWV surroundings smoothly. Applying a mansard roof, three stories, and on street parking are appropriate responses for our intervention as well.
2016 Forbes Avenue
2024 Forbes Avenue
2008 Forbes Avenue
2019 Forbes Avenue
Lot Size: 1,656 sq. ft. Levels: 3 Parking: On street
Lot Size: 2,706 sq. ft. Levels: 3 Parking: On street
Lot Size: 3,456 sq. ft. Levels: 3 Parking: On street
Lot Size: 2,880 sq. ft. Levels: 3 Parking: On street
PROJECT SCOPE 7<32/2*< &$6( 678'<
PS 10.04
PRECEDENT STUDY 3URMHFW ,QIRUPDWLRQ %RQDLUHVWUDDW *URQLQJHQ pvan Architects, 2008 The Netherlands
6DORQJHQ
KKA Architects, 2012 Malmo, Sweden
House KE12
SoHo Architektur, 2010 Memmingen, Germany
PS 11.00
PROJECT SCOPE 7<32/2*< &$6( 678'<
,PDJHV
ACTION UPTOWN: 2FILL
Plans and Sections
ARC48_550
$SSOLFDELOLW\ WR $FWLRQ 8SWRZQ This precedent was useful to Uptown because the project creates a continuous facade treatment, which is similar to the one on Forbes Avenue on Uptown. The project uses a sensible material palate and standard dimensions elements that are easy to install and replicate. The use of cantilevered terraces celebrates indoor outdoor relationships and allows residents on the upper levels to have outdoors space.
This project uses a inclined roof to take advantage of the buildingâ&#x20AC;&#x2122;s southern exposure and effectively reducing the need for mechanical systems because of passive solar gains. A small terrace is inserted into the inclined roof porting that allows for a JUDWHU Ă&#x20AC;RRU SODWH RQ WKH WKLUG Ă&#x20AC;RRU ZKHUH SDUWV RI WKH URRI FDQ be very near the occupants there. The buildingâ&#x20AC;&#x2122;s proportions and relation to the street create a strong connection to its surroundings but the color white makes it stand out too much. 7KH SODQ UHYHDOV WKDW D FDU DQ ÂżW LQVLGH WKH KRXVH \HW VWLOO EH near the living room. This is interesting because part of Lot 157 is currently used as a parking for the owners, so this is direcly applicable to our site.
This buildingâ&#x20AC;&#x2122;s simple layout allows for cheaper construction EHFDXVH RI UHGXFHG LQWHULRU SDUWLWLRQV HIÂżFLHQW NLWFKHQ DQG bathroom space, and central stair. The staircase bisects the building in two parts: one private and the other public. Placing the staircase in the interior allows for habitable rooms to be located around the perimeter and take advantage of solar gain, YHQWLODWLRQ DQG YLHZV WR WKH RXWGRRUV 7KH EXLOGLQJV ÂżWV ZHOO ZLWK its urban context and adjacent buildings, emphasizing a sense of continuity along the street.
PROJECT SCOPE 7<32/2*< &$6( 678'<
PS 11.01
MASSING STUDY Negative Qualities
Positive Qualities
Negative Qualities
Positive Qualities
Negative Qualities
Positive Qualities
Negative Qualities
Positive Qualities
Negative Qualities
Positive Qualities
Negative Qualities
Positive Qualities
Bad
PP 1.00
Good
PROJECT PROPOSAL 0$66,1* 678'<
Sun
Connection to Nature
Access to Forbes Av
Spatial Arrangement
ACTION UPTOWN: 2FILL
3 Bedroom Home 2-3 Bedroom home on the VHFRQG DQG WKLUG ÀRRUV ZLWK access to a roof terrace and the basement.
Negative Qualities
Positive Qualities
ARC48_550
&KRVHQ 0DVVLQJ $UUDQJHPHQW 3ULYDWH 2XWGRRU 6SDFH These massing options enable both units to have visual access to the community garden, access to a private outdoor space either as a balcony or garden, and good connection to Forbes Avenue.
0D[LPL]H VXQ H[SRVXUH The tiered terraced approach allows us to take advantage of the southern exposure of the site.
6WURQJ &RQQHFWLRQ WR 1DWXUH Each tier level creates private balconies for the residents and LQFUHDVHV WKHLU FRQQHFWLYLW\ WR QDWXUH DQG HQKDQFH LQGRRU RXWGRRU relationships. Having multiple levels of terraces will connect this intervention with the community garden in the back and create a strong feeling of living surrounded by nature.
5HVSRQVLYH 6SDWLDO $UUDQJHPHQW WR &RQWH[W 7KH ¿UVW ÀRRU DSDUWPHQW KDV DFFHVV WR SULYDWH RXWGRRU VSDFH at the backyard the most public program. The public program is oriented towards Forbes Avenue while private programs are ORFDWHG DGMDFHQW WR WKH EDFN\DUG 7KH KRXVH RQ WKH WRS WZR ÀRRUV reverse the relationship of public to private where the bedrooms overlook Forbes Avenue and public space such as the living room have visual access to the community garden and access to private outdoor space on the balcony and roof terrace. 7KH ¿UVW ÀRRU DSDUWPHQW WKRXJK LQGHSHQGHQW IURP WKH QG ÀRRU KRXVH DERYH VWLOO VKDUHV ZDWHU ZDOOV IRU WKH NLWFKHQ DQG EDWKURRP The vertical circulation also connects the entire building from the WKLUG ÀRRU GRZQ WR WKH EDVHPHQW
2 Bedroom Apartment 2 Bedroom apartment on the ¿UVW ÀRRU ZLWK DFFHVV WR WKH backyard and basement.
PROJECT PROPOSAL MASSING
PP 1.01
PROGRAM ADJACENCIES 6LQJOH )DPLO\ +RPH 7KH RQ WKH WRS WZR À RRUV KDYH YLVXDO DFFHVV to Forbes Avenue on the north face of the building and views to the community garden on the southern side of the building. Due to this, the bedrooms and other private spaces are located on the northern side of the building whereas the public spaces such as the living room have visual access to the community garden.
3rd Floor
It is very important to provide the family living in the home with private outdoor spaces. This is manifested in the roof terrace and the balcony adjoined to the family living room. 7KH WKLUG À RRU EHGURRP LV RSHQ WR WKH staircase and roof terrace and can act as both a master bedroom or a large home RI¿ FH
2nd Floor
N
PP 1.02
PROJECT PROPOSAL 352*5$0
ACTION UPTOWN: 2FILL
ARC48_550
2QH %HGURRP $SDUWPHQW 1st Floor
Basement
7KH ¿ UVW À RRU DSDUWPHQW KDV DFFHVV WR private outdoor space at the backyard and the most public program is along Forbes Avenue with private programs such as the bedroom in the back. 7KH ¿ UVW À RRU DSDUWPHQW WKRXJK LQGHSHQGHQW IURP WKH À RRU KRXVH DERYH VWLOO VKDUHV ZDWHU ZDOOV IRU WKH NLWFKHQ DQG EDWKURRP The vertical circulation also connects the HQWLUH EXLOGLQJ IURP WKH WKLUG À RRU GRZQ WR the basement.
6KDUHG %DVHPHQW Both the single family home and the single bedroom apartment unit have direct access to the basement. In the basement shared laundry and storage spaces are allocated. Laundry machines will be shared by both units, cutting down the cost of utilities and requiring the purchase of only one washer and dryer. By moving these programs to the basement both residential units keep the space that would have been required for a laundry room as living room and bedroom space. The basement will be unconditioned so utility expenses will not be increased due to the basement.
PROJECT PROPOSAL 352*5$0
PP 1.03
CODE AN
NALYSIS
CODE ANALYSIS Global, Urban, Site & Zoning *(1(5$/ 5(6,'(17,$/ R101.1 The code will apply to the construction and repair of the houses and additions outlined in the report. R102.7 Residence may retain occupancy unless alterations to the house cause unsafe conditions as laid out in the International Property Maintenance Code or the International Fire Code.
17’ 3” > 15’
R105.1 2ZQHU RI WKH KRXVH PXVW ¿UVW DSSO\ IRU WKH UHTXLUHG SHUPLWV IURP WKH 3LWWVEXUJK %XUHDX of Building Inspection before any alterations are made.
36’ 7” < 40’
5(*,21$/ =21,1* Maximum Height: 40 ft or 3 stories Minimum Required Setback: 15 ft
PERMITS R105.1 7KH RZQHU RI WKH KRXVH PXVW ¿UVW DSSO\ IRU WKH UHTXLUHG SHUPLWV IURP WKH 3LWWVEXUJK Bureau of Building Inspection before any alterations are made.
6 psf < 15 psf
13.2 psf < 15 psf
&(57,),&$7( 2) 2&&83$1&< R110.1 House may not be occupied until an inspector from the Pittsburgh Bureau of Building ,QVSHFWLRQV LVVXHV D &HUWL¿FDWH RI 2FFXSDQF\ R110.4 5HVLGHQWV DUH DOORZHG WR UHTXHVW D WHPSRUDU\ FHUWL¿FDWH RI RFFXSDQF\ WKDW DOORZV WKHP to reside in the house while work is being conducted as long as the inspector from the Pittsburgh Bureau of Building Inspections deems the conditions safe.
%8,/',1* 3/$11,1* R301.2.2.2.1 Average dead loads shall not exceed 15 lbs. per square foot for the combined roof and ceiling assemblies. Dead loads for walls above grade shall not exceed: 15 lbs. SHU VTXDUH IRRW IRU H[WHULRU OLJKW IUDPH ZRRG ZDOOV 10 lbs SHU VTXDUH IRRW IRU LQWHULRU OLJKW IUDPH ZRRG ZDOOV
CA 1.00
CODE ANALYSIS %8,/',1*
Roof and Ceiling Assembly Dead Load: 6 psf Asphalt Shingles: 2 psf Wood: 3 psf &KDQQHO 6XVWSHQGHG 6\VWHP SVI
Exterior Walls:13.2 psf Wood Paneling: 2.5 psf :RRG VWXGV ´ SVI SIP Panels: 5 psf Gypsum Wallboard: 5 psf
ACTION UPTOWN: 2FILL
ARC48_550
Global, Building 1$785$/ /,*+7
9(17,/$7,21 $1' +($7,1*
R303.7 Required glazed openings shall open directly onto a street or public alley or a yard or court located on the same lot as the building.
R303.1 Every room that is inhabited must have a ZLQGRZ DUHD RI DW OHDVW RI WKH URRPÂśV Ă&#x20AC; RRU area. Natural Ventilation shall be through windows, doors, and louvers to the outside.
R308.6.2 6N\OLJKWV DQG 6ORSHG *OD]LQJ 0XVW EH PDGH RI IXOO\ WHPSHUHG JODVV KHDW VWUHQJWKHQHG JODVV ZLUHG JODVV DSSURYHG ULJLG SODVWLFV RU ODPLQDWHG JODVV ZLWK D PLQXPXP LQFK polyvinyl butyral interlayer.
R303.3 %DWKURRPV PXVW KDYH D ZLQGRZ DUHD RI DW OHDVW VTXDUH IHHW XQOHVV DUWLÂż FLDO OLJKW DQG D mechanical ventilation system are installed.
R303.6 Stairway Illumination: All interior and exterior stairways shall be provided with a means to illuminate the stairs, including the landings and treads.
R303.8 Required Heating: When the winter temperature is below 60o F every dwelling unit shall be provided with heating facilities capable of maintaining room temperature of 68o F at a SRLQW IHHW DERYH WKH Ă&#x20AC; RRU DQG IHHW IURP H[WHULRU ZDOOV LQ DOO KDELWDEOH URRPV
200 sqft exterior 16 sqft glazing 8% GLAZING
9,6,7 $%,/,7< ADA Ramp Adaptation DISABLED LIFT USED Width of doors ´ 0,1,080
œ ´
BEDROOM 145 SF
CLOSET 47 SF
BATH ROOM 47 SF
´
ENTRY 24 SF
œ ´
KITCHEN 108 SF
LIVING 2 212 SF
DISABLED ACCESSIBLE LIFT
´
LIVING 1 331 SF
´
´ ´
4â&#x20AC;&#x2122;4
´ ´
œ ´
œ ´
´
´
0,1,080 )22735,17 63(&,),& 86(6
.,7&+(16 %$7+52206
R304.1 Each living unit must have at least one habitable room of no less than 120 square feet.
R306.2 Each living unit in the house must have a kitchen with a sink.
R304.2 All habitable rooms, except kitchens, must have a PLQLPXP Ă&#x20AC; RRU DUHD RI VTXDUH IHHW and not less than 7 feet in any horizontal direction.
R307.2 :DOOV DERYH WKH EDWKWXEV DQG VKRZHUV PXVW EH Âż QLVKHG ZLWK D QRQDEVRUEHQW VXUIDFH 7KHVH VXUIDFHV PXVW ULVH DW OHDVW VL[ IHHW DERYH WKH Ă&#x20AC; RRU
R304.3 Any area of a room that has a sloped ceiling less than 5 feet or a furred ceiling less than IHHW IURP WKH Âż QLVKHG Ă&#x20AC; RRU ZLOO QRW EH FRXQWHG WRZDUGV WKH KDELWDEOH DUHD IRU WKDW URRP R305.1 All habitable spaces such as bedrooms, hallways, bathrooms, and basements must have a minimum ceiling height of 7 feet.
CODE ANALYSIS %8,/',1*
CA 1.01
CODE ANALYSIS Global, Building :,1'2:6
EGRESS
R308.4 Safety, tempered glass must be provided in these hazardous locations:
R311.1 All portions of the living units must have a continuous and unobstructed path of vertical and horizontal egress travel to the outside.
Glazing panels of swinging and folding doors *OD]LQJ LQ DQ LQGLYLGXDO Âż [HG RU RSHUDEOH SDQHO DGMDFHQW WR D GRRU ZKHUH WKH QHDUHVW YHUWLFDO HGJH LV ZLWKLQ D ´ DUF RI WKH GRRU LQ D FORVHG SRVLWLRQ DQG ZKRVH ERWWRP HGJH LV OHVV WKDQ GHJUHHV DERYH WKH Ă&#x20AC; RRU
R311.2 Minimum one egress door will exist for each living unit. The door opening must be a minimum 32 inches wide, 78 inches tall, and be able to open a full 90 degrees.
*OD]LQJ DGMDFHQW WR VWDLUZD\V DQG ODQGLQJ ZLWKLQ ´ KRUL]RQWDOO\ RI D ZDONLQJ VXUIDFH ZKHQ WKH JOD]LQJ LV OHVV WKDQ ´ DERYH WKH ZDONLQJ VXUIDFH
R311.3 7KHUH PXVW EH D ODQGLQJ RQ ERWK VLGHV RI H[WHULRU GRRUV QR OHVV WKDQ ´ GHHS R311.7 6WDLUZD\V VKRXOG EH QR OHVV WKDQ ´ LQ FOHDU ZLGWK DERYH WKH KDQGUDLO DQG ´ LQ FOHDU ZLGWK DW DQ EHORZ WKH UDLO LI WKHUH LV D UDLO RQ RQH VLGH 2WKHUZLVH ´ ZKHUH WKHUH are rails on both sides. 7KHUH PXVW EH DW OHDVW œ ´ KHDGURRP DERYH DOO VWDLUV +DQGUDLO VKRXOG EH SURYLGHG IRU a run of stairs equal to or longer than four risers.
:$// &216758&7,21 R601.3 Vapor barrier is required on the interior side of frame walls to prevent water damage. This does not apply to basement walls and any portion of a wall that is below grade. R602.3 Studs in frame walls must be continuous from support at the sole place to a support at the top plate. The studs must be capped with a double top plate to allow for overlapping at corner conditions. End joists in the plates must be offset minimum of 24 inches. R302.10.1 7KH LQVXODWLRQ DQG YDSRU EDUULHUV LQVWDOOHG LQ DOO ZDOOV Ă&#x20AC; RRUV DQG Ă&#x20AC; RRUV PXVW QRW H[FHHG D Ă&#x20AC; DPH LQGH[ RI DV WHVWHG E\ $670 ( RU 8/
Wall R Value: 24 SMOOTH TEXTURE VINYL SIDING POLYPROPYLENE EXTERIOR HOUSE WRAP
,168/$7,21 N1102.2
Building thermal envelope shall meet these requirements: Climate Zone 5
Fenestration U Factor Skylight U Factor Ceiling R Value Wood Frame Wall R Value Mass Wall R Value Floor R Value Basement Wall R Value Slab R Value Crawl Space and Wall R Value
CA 1.02
.35 .60 38 19 13 30 10/13 10, 2 ft 10/13
CODE ANALYSIS %8,/',1*
´ 6,3 :$// ´; ´ ´ 2 &
´ *<3680 WALL BOARD
ACTION UPTOWN: 2FILL
ARC48_550
Life Safety (0(5*(1&< 5(6&8(
´ [ ´
R310.1 Every sleeping room must have at least one operable emergency escape and rescue RSHQLQJ WKDW KDV D PD[LPXP VLOO RI ´ DERYH WKH À RRU DQG D PLQLPXP FOHDU RSHQLQJ RI 5.7 square feet. The minimum opening height must be ´ and the minimum opening width must be ´.
*8$5'6 R312.1 *XDUG UDLOV DUH UHTXLUHG DORQJ DOO VWDLUV DQG UDPSV WKDW DUH PRUH WKDQ ´ YHUWLFDOO\ IURP WKH À RRU RU JURXQG 7KHVH JXDUGV PXVW EH QR OHVV WKDQ ´ WDOO 7KH JXDUGV PXVW also QRW KDYH DQ\ VSDFHV ODUJHU WKDQ ´
$8720$7,& ),5( 635,1./(56
Maximum distance 44’
R313.1 $XWRPDWLF UHVLGHQWLDO ¿ UH VSULQNOHU V\VWHP LV UHTXLUHG LQ QHZ FRQVWUXFWLRQV
602.( $/$506 R313.1 Smoke alarms will be installed in every sleeping area, in the area directly outside the sleeping areas, basements and habitable attics. R314.4 Smoke alarms must receive their primary power from the building wiring and be connected to a battery in case of a power outage.
)281'$7,216 R401.3 Surface drainage must be diverted to a storm water sewer or other collection point. The lot must be graded so that water drains away from the foundation and the slope of the JURXQG IDOOV D PLQLPXP RI ´ ZLWKLQ WKH ¿ UVW ¶ R401.4 A soil test should be conducted if the soil is deemed questionable because of expansive, compressible, or shifting characteristics. The determination will come from WKH EXLOGLQJ RI¿ FLDO IURP WKH 3LWWVEXUJK %XUHDX RI %XLOGLQJ ,QVSHFWLRQV
´
CODE ANALYSIS %8,/',1*
CA 1.03
SPECIFIC
CATIONS
&6, &RQVWUXFWLRQ 6SHFLÂżFDWLRQV ,QGH[ Division 1 0111
Summary of the work
011131000000
| Architectural Fees
01 11 19
| Purchase Contracts
_ $OO WKH ZRUN DV VSHFLÂżHG LQ GRFXPHQWV _ $OO SURGXFWV HTXLSPHQW DQG PDWHULDOV KDYH EHHQ VSHFLÂżHG E\ WKH DUFKLWHFW LQ this sheet. The contractor is responsible for ordering the deliveries, storing all materials, and coordinating their installation.
Division 2 D2040
Rain Water Drainage Utilities
D20402101880
| Rainwater Drainage 5RRI GUDLQ ':9 39& ´ GLDP 3LSLQJ œ KLJK
| Furnish and erect all site work elements based on documents
Division 3 $ $
Foundations and Basement Construction
A10301204480
| Slab on Grade ´ WKLFN QRQ LQGXVWULDO UHLQIRUFHV
A20101102340
| Basement Excavation 8â&#x20AC;&#x2122; deep, sand, gravel, or common earth, on site storage
A20201105000
| Basement Walls œ KLJK ZDOO ´ WKLFN
_ $OO WKH ZRUN DV VSHFLÂżHG LQ GRFXPHQWV | Contractor is responsible for testing studies of soil compaction prior to FRQVWUXFWLRQ RI WKH FDVW LQ SODFH FRQFUHWH ZDOOV 7KH DUFKLWHFW LV QRW OLDEOH for structural viability of the design based on representations within the construction documents. _ 7KH FRQFUHWH Ă&#x20AC;RRU LV WR EH ´ GHHS DQG WKH ZDOOV ´ WKLFN
Division 4 % %
Superstructure and Exterior Enclosure
B10102161000
| Wood Stud ´[ ´ ´ R F
B10102612400 B10102612800
| Wood Joist ´[ ´ ´ R F ´[ ´ ´ R F
B10102161025
_ +HDGHU )RRWHU ´ [ ´
C10101280540
| Base Plate/ Top Plate for SIP ´ [ ´ | Brick Veneer/Wood Stud Backup [ ZRRG ´ VWXG VSDFLQJ
B20101292100 B20101500400
| Install work using levels and plumb lines to stay accurate to required lines. Make sure all members are accurately cut and securely fastened. _ &ORVHO\ ÂżW URXJK FDUSHQWU\ WR RWKHU DGMDFHQW FRQVWUXFWLRQ
| Wood Exterior Siding
Division 5 SIP Construction 061210100110
_ 6,3 :DOO ´ WKLFN
061210100210
_ 6,3 5RRI ´
061210100110
_ 6,3 )ORRU ´
SP 1.00
SPECIFICATIONS &6, '(6,*1$7(' 0$7(5,$/ $1127$7,21 /(*(1'
ACTION UPTOWN: 2FILL
ARC48_550
Division 6 B20, C10
Openings
B20201023100
| Wood Windows Wood Double hung insulated glass, 2â&#x20AC;&#x2122; ´ [ Âś ´
B20201024550
| Wood Windows Picture window insulated glass
C10201201600
| Wood Door/ Wood Frame )LEHUERDUG ORZ GHQVLW\ ´ WKLFN 5
C10201141000
| Metal Door/ Metal Frame )OXVK +DOORZ VWHHO GRRU Ă&#x20AC;RDW JODVV Âś ´ [ Âś ´
C20101100560
| Stair C.I.P. Stairs with landing, Concrete in place, free standing
| Provide all window work complete with required accessories as indicated in the documents and as required for a complete installation.
Division 7 & &
'U\ZDOO &RPSRQHQWV )ORRU )LQLVKHV
C10101241500
| Drywall Partitions ´ 6' J\SVXP QRWKLQJ LQ RSSRVLWH face
C30204100500
| Wood Composite Flooring Polyester with colored quart
C30204101600
| Tile and covering Bathrooms Vinyl tile, maximum
C30102300080
| Paint and Covering Painting Interior on plaster or drywall. Primer, 1st and 2nd coat.
C10101440345
| Batten
| Do not install drywall in any location where it may be exposed directly to water. _ 'R QRW H[FHHG ´ LQ œ YDULDWLRQ IURP SOXPE OLQH RU OHYHO LQ DQ\ exposed line or surface except at joint between boards. Do not H[FHHG ´ YDULDWLRQ EHWZHHQ SODQHV RU DEXWWLQJ HGJHV RU HQGV 6KLP DV UHTXLUHG WR FRPSO\ ZLWK VSHFL¿HG WROHUDQFHV | Paint exposed surfaces.
SPECIFICATIONS &6, '(6,*1$7(' 0$7(5,$/ $1127$7,21 /(*(1'
SP 1.01
&6, &RQVWUXFWLRQ 6SHFLÂżFDWLRQV ,QGH[ 'LYLVLRQ 3OXPELQJ D20
Plumbing Fixtures
D20103101560
| Lavatory Systems ´ [ ´ RYDO
D20104101720
| Kitchen Sink Systems .LWFKHQ VLQN Z WULP FRXQWHU WRS VLQJOH ERZO ´ [ ´
D20109201180
| Two Fixture Bathroom Lavatory, Water closet, 2 wall plumbing stand alone
D20202501780
| Domestic Water Distribution *DV ÂżUHG ZDWHU KHDWHU FRPPHUFLDO degrees F rise. Copper tubbing, type L, solder joint
D30
Electric Domestic Water Heaters
D30201020112
| Heat generating System Boiler, electric
D50
Electrical
D50101200200
| Electric Service/ distribution Breakers, metering, 20â&#x20AC;&#x2122; conduit and wire 3 phase. 4 wire, 60 A
D50102400200
| Switchgear
D50201100190
| Lighting and branch wiring Duplex receptable 2.5 per 1000 s.f.
D50201300200
| Lighting and branch wiring Light switch controllers
D50202140380
| Lighting and branch wiring ,QFDQGHVFHQW Âż[WXUH UHFHVV PRXQWHG
D50905101000
| Electric Baseboard Radiation Electric baseboard radiation, low density, 9 kW
| Install pumping apparatus as detailed in the documents or as recommended by the respective manufacturer, to be entirely operable for its intended use. | Make all piping connection as shown on documents and install all appurtenances. | Provide all labor, materials, tools, machinery, equipment and service necessary to complete the electrical and plumbing under this contract. | All systems and equipment shall be complete in every aspect and all items of material, equipment and labor shall be provided for a fully operational system and ready for use. Coordinate the work with the work of the other trades in RUGHU WR UHVROYH DOO FRQĂ&#x20AC;LFWV ZLWKRXW LPSHQGLQJ WKH MRE SURJUHVV
'LYLVLRQ )XUQLVKLQJ E20
Furnishings
E20202100720
| Furnishings Upholster seats, single economy
E20202202300
| Furniture and Accessories Dressing unit, built in, economy
E20202200910
| Furniture and Accessories Wardrobes and coat racks
SP 1.02
SPECIFICATIONS &6, '(6,*1$7(' 0$7(5,$/ $1127$7,21 /(*(1'
ACTION UPTOWN: 2FILL
SPECIFICATIONS &6, '(6,*1$7(' 0$7(5,$/ $1127$7,21 /(*(1'
ARC48_550
SP 1.03
CONSTR
RUCTION
NORTHERN EXTERIOR PERSPECTIVES
7KH LQVHUWLRQ RI D QHZ URZ KRXVH 多 OOV LQ WKH missing tooth along this densely built street. The building design addresses typologies and design elements found in the area, namely the mansard roof, purposely placed windows to pace the street, dormer windows, and horizontal geometry of exterior materials.
AT 1.00
ADAPTIVE TRANSFORMATION 1257+:(67 (;7(5,25 3(563(&7,9(
ACTION UPTOWN: 2FILL
ADAPTIVE TRANSFORMATION 1257+($67 (;7(5,25 3(563(&7,9(
ARC48_550
AT 1.01
SOUTHERN EXTERIOR PERSPECTIVES
The rear exterior of the house addresses the open back lot that is immediately adjacent to the community garden. The patio and second À RRU EDOFRQ\ SURYLGH HDFK XQLW ZLWK SULYDWH outdoor space that creates visual connection to the garden and encourages a sense of FRPPXQLW\ 7KH EULFN H[WHULRU ¿ QLVK UHVSRQGV to the adjacent buildings reinforcing the continuity of the entire street.
AT 1.02
ADAPTIVE TRANSFORMATION 6287+:(67 (;7(5,25 3(563(&7,9(
ACTION UPTOWN: 2FILL
ADAPTIVE TRANSFORMATION 6287+($67 (;7(5,25 3(563(&7,9(
ARC48_550
AT 1.03
PLANS
AT 1.04
ADAPTIVE TRANSFORMATION 3/$16
ACTION UPTOWN: 2FILL
ADAPTIVE TRANSFORMATION 3/$16
ARC48_550
AT 1.05
SECTIONAL PERSPECTIVES
The raised entry responds to the building typology of the row houses along Forbes Avenue. The entry itself wraps to the corner of the front facade and tucks into the building, creating a private entry foyer for entry into the single EHGURRP DSDUWPHQW RQ WKH JURXQG Ă&#x20AC;RRU DQG VWDLUFDVH WR WKH XSSHU VWRU\ IDPLO\ DSDUWPHQW 7KH DERYH SHUVSHFWLYH FXWV WKURXJK WKH YHUWLFDO FLUFXODWLRQ FRUH SULYDWH VSDFHV RQ WKH JURXQG Ă&#x20AC;RRU SXEOLF OLYLQJ VSDFHV RQ WKH VHFRQG Ă&#x20AC;RRU DQG JUHHQ RXWGRRU VSDFH DFFHVVLEOH IURP WKH WKLUG Ă&#x20AC;RRU 7KH XSSHU RSSRVLWH VHFWLRQDO SHUVSHFWLYH SURYLGHV D YLHZ MXVW past the rear wall facing north through the two apartments. The skylights along the roof allow light to penetrate deep into the kitchen and living spaces. The lower opposite sectional perspective faces south and shows entry and exit from the vertical circulation core, stacking of rooms utilizing plumbing, and views that penetrate to the rear of the house.
AT 2.00
ADAPTIVE Transformation 6(&7,21$/ 3(563(&7,9(
ACTION UPTOWN: 2FILL
ADAPTIVE TRANSFORMATION 6(&7,21$/ 3(563(&7,9(
ARC48_550
AT 2.01
AT 3.08 DET. 3 2'
49'-0 1/2" 2'
2'
2'
2'
2'
2'
2'
2'
2'
2'
2'
2'
2'
2'
5'-0 5/8" 3'-6 7/8"
AT 3.07 HALL
AT 3.11 2'
DET. 4
2'
006
DET. 3
63 SF
10'-6 1/4" 4'-2 3/8"
2'-2 3/8"
LIVING 2 007
17'-5 3/4"
2'
2'
212 SF KITCHEN/DINING
16'-4 1/2"
005 4'-2 3/8"
2'-2 3/8" 5'-4 7/16"
17'
2'
108 SF
3'-4 3/4"
4'-2 1/4"
10'-3 1/2"
10'-6 1/4"
7'-8"
2'
3'-6 1/16"
5 1/4"
BATHROOM ENTRY
2'-8 1/16"
008
AT 3.08 DET. 4 8'-3"
4'-4"
004
53 SF
3'
CLOSE
24 SF
003
4
1'-5 7/16"
2'
3'-3 3/4"
1'-8 1/4"
4'-6 1/2"
6'-4 1/16"
3'-3"
3'-2 3/4"
10'-6"
3'
5'-1" 43'-2 15/16"
FIRST FLOOR PLAN 3/16”=1’ AT 3.00
ADAPTIVE Transformation ),567 )/225 3/$1
4'-5"
ACTION UPTOWN: 2FILL
ARC48_550
AT 3.08 2'
ET
2'
2'
2'
2'
2'
DET. 1
2'
2'-7 1/2"
2'-6"
3'-3"
LIVING 1 002
5'-6"
13'-10"
331 SF
2'
10'-7 1/16" 4'-10"
6'-10"
2'
3'-9 1/8"
3'-6"
BEDROOM
3'
47 SF
001
5'-6"
10'-7 1/4"
145 SF 2'
3'-7 1/8" 3'-0 1/4"
13'-8 9/16"
AT 3.09 DET. 5
AT 3.08 DET. 2
GENERAL NOTES 1. THESE DOCUMENTS ARE THE COPYRIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE URBAN DESIGN BUILD STUDIO. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AND AS STIPULATED ON SHEET IN1.00. THIS RESTRICTION AND OWNERSHIP OF INTELLECTUAL PROPERTY GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE LETTERHEAD ISSUED BY THE DIRECTOR OF THE URBAN DESIGN BUILD STUDIO. 2. NONE OF THE DOCUMENTS INCLUDED IN THE DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/ OR PRE-CONSTRUCTION ANALYSIS SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “IN” AND “CA” SERIES (GOVERNING USE STIPULATIONS AND CODE ANALYSIS) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH CONTRACTS AND/OR PROCUREMENT. GOVERNING USE STIPULATION SHEETS AND CODE ANALYSIS (“IN” AND “CA” SERIES DOCUMENTS) 25'-8 3/4" PROVIDE CODE, PROCEDURAL, AND USE GUIDELINES GOVERNING ALL INFORMATION CONTAINED WITHIN THE DOCUMENTS. ANY AND ALL ENTITIES REFERENCING CONTENT INCLUDED SHALL DO SO ONLY IN THE CONTEXT OF THE ENTIRE VOLUME. NEITHER THE OWNER OF THE INTELLECTUAL PROPERTY NOR THEIR AGENTS ASSUME RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE DOCUMENTS. 3.DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED ENTITIES UTILIZING THE DOCUMENTS SHALL CONTACT OWNER OF INTELLECTUAL PROPERTY IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY THE OWNER OF THE INTELLECTUAL PROPERTY. 4. USE OF ALL CONSTRUCTION MATERIALS AND INSTALLATIONS PROPOSED SHALL CONFORM TO THE IRC 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURER’S STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH. KEY NOTES 1. ALL GYPSUM WALL FINISHES ARE LEVEL 4 UNLESS WITH A BATTEN SYSTEM. 2. WHEN BATTENS ARE USED, GYPSUM WALLS ARE MINIMUM LEVEL 3 FINISH 3.2X2 BATTENS MUST BE ALIGNED WITH THE 2ND FLOOR FLOOR JOIST O.C.
ADAPTIVE TRANSFORMATION ),567 )/225 3/$1
AT 3.01
AT 3.08
54'-7 1/4"
DET. 1
32'-1 1/4" 9'-9 7/8"
9'-1"
11'-8 7/8"
3'-2 7/8"
2'
BATHROOM 8'-8 1/4" 10'-1 7/8"
2'-2 7/8"
013
BEDROOM 1
4'-2 7/8"
014
85 SF 3'-8"
92 SF KITCHEN
2'-4"
2'
21'-2 1/4" 2'-2 7/8"
3'-9 1/8"
4'-2 7/8"
011
4'-5 1/2"
107 SF
11'-8 7/8"
3'-3 3/4" 4'-2 15/16"
2'
HALL
5'-7" 3'-6 3/8"
2'-2 7/8"
4'-2 7/8"
108 SF
AT 3.07
BEDROOM 2 015
9'-6 3/8"
012
DET. 4
87 SF
11'
8'-0 3/4"
2'
AT 3.06 DET. 1
3'-2 5/8"
9'-1"
8'-1 3/4" 3'-5 1/16"
4'-5"
AT 3.08 DET. 4
6'-6" 6'-1 15/16"
SECOND FLOOR PLAN 3/16”=1’ AT 3.02
ADAPTIVE Transformation 6(&21' )/225 3/$1
11'-6 1/4" 43'-1 5/16"
ACTION UPTOWN: 2FILL
ARC48_550
AT 3.06 DET. 2
22'-6"
2'
2'
2'
2'
21'-11 1/2" 2'
2'
2'
2'
2'
2'-9 1/4"
AT 3.12 DET. 1
AT 3.11
2'
DET. 4 9'-1 1/4"
DINING ROOM 010
5'-6" 3'-6" 12'-9 1/2"
255 SF
2'
5'-4"
2'-6 1/4" 25'-7 1/4"
LIVING ROOM 009
6'
305 SF
12'-9 1/8" 12'-9 3/4" 1'-1"
2'
3'
24'-0 1/16" 5'-4"
AT 3.10
AT 3.08
DET. 1
DET. 2
GENERAL NOTES 1. THESE DOCUMENTS ARE THE COPYRIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE URBAN DESIGN BUILD STUDIO. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AND AS STIPULATED ON SHEET IN1.00. THIS RESTRICTION AND OWNERSHIP OF INTELLECTUAL PROPERTY GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE LETTERHEAD ISSUED BY THE DIRECTOR OF THE URBAN DESIGN BUILD STUDIO. 2. NONE OF THE DOCUMENTS INCLUDED IN THE DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR PRE-CONSTRUCTION ANALYSIS SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “IN” AND “CA” SERIES (GOVERNING USE STIPULATIONS AND CODE ANALYSIS) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH CONTRACTS AND/ OR PROCUREMENT. GOVERNING USE STIPULATION SHEETS AND CODE ANALYSIS (“IN” AND “CA” SERIES DOCUMENTS) PROVIDE CODE, PROCEDURAL, AND USE GUIDELINES GOVERNING ALL INFORMATION CONTAINED WITHIN THE DOCUMENTS. ANY AND ALL ENTITIES REFERENCING CONTENT INCLUDED SHALL DO SO ONLY IN THE CONTEXT OF THE ENTIRE VOLUME. NEITHER THE OWNER OF THE INTELLECTUAL PROPERTY NOR THEIR AGENTS ASSUME RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE DOCUMENTS. 3.DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED ENTITIES UTILIZING THE DOCUMENTS SHALL CONTACT OWNER OF INTELLECTUAL PROPERTY IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY THE OWNER OF THE INTELLECTUAL PROPERTY. 4. USE OF ALL CONSTRUCTION MATERIALS AND INSTALLATIONS PROPOSED SHALL CONFORM TO THE IRC 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURER’S STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH. KEY NOTES 1. ALL GYPSUM WALL FINISHES ARE LEVEL 4 UNLESS WITH A BATTEN SYSTEM. 2. WHEN BATTENS ARE USED, GYPSUM WALLS ARE MINIMUM LEVEL 3 FINISH 3.2X2 BATTENS MUST BE ALIGNED WITH THE 3RD FLOOR FLOOR JOIST O.C.
ADAPTIVE TRANSFORMATION 6(&21' )/225 3/$1
AT 3.03
54'-8 3/16"
10'-8 1/8"
10'-6 1/2"
AT 3.15 DET. 2
M. BATHROOM 017
12'-5 1/4"
9'-9 1/4"
100 SF
M. BEDROOM 016
AT 3.09 DET. 5
172 SF
13'-3 3/4"
16'-3 1/4" 3'-9 7/16"
AT 3.16
11'-1 1/8"
2'-6 1/8"
DET. 1
25'-7 1/4" 1'-11 9/16" 2'
8'-9" 8'-9"
13'-11 1/2" 7 1/2"
READING RM
6'
018
2'-8"
10'-8"
77 SF
4'
5'-10 3/8"
12'
11 3/8"
7'-8 1/2"
READING RM 019
19 SF
3'-11 3/4"
4'-5"
4'-10 7/16"
10'-6" 19'-9 7/16"
4'-11 1/4"
AT 3.09 DET. 5
THIRD FLOOR PLAN 3/16”=1’ AT 3.04
ADAPTIVE Transformation 7+,5' )/225 3/$1
16'-4 3 49'-8 15/16"
ACTION UPTOWN: 2FILL
GENERAL NOTES 1. THESE DOCUMENTS ARE THE COPYRIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE URBAN DESIGN BUILD STUDIO. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AND AS STIPULATED ON SHEET IN1.00. THIS RESTRICTION AND OWNERSHIP OF INTELLECTUAL PROPERTY GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE LETTERHEAD ISSUED BY THE DIRECTOR OF THE URBAN DESIGN BUILD STUDIO.
29'-11 1/2"
2. NONE OF THE DOCUMENTS INCLUDED IN THE DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR PRECONSTRUCTION ANALYSIS SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “IN” AND “CA” SERIES (GOVERNING USE STIPULATIONS AND CODE ANALYSIS) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH CONTRACTS AND/OR PROCUREMENT. GOVERNING USE STIPULATION SHEETS AND CODE ANALYSIS (“IN” AND “CA” SERIES DOCUMENTS) PROVIDE CODE, PROCEDURAL, AND USE GUIDELINES GOVERNING ALL INFORMATION CONTAINED WITHIN THE DOCUMENTS. ANY AND ALL ENTITIES REFERENCING CONTENT INCLUDED SHALL DO SO ONLY IN THE CONTEXT OF THE ENTIRE VOLUME. NEITHER THE OWNER OF THE INTELLECTUAL PROPERTY NOR THEIR AGENTS ASSUME RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE DOCUMENTS.
2'-7"
1'-5"
2'-7"
3/16"
ARC48_550
3.DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED ENTITIES UTILIZING THE DOCUMENTS SHALL CONTACT OWNER OF INTELLECTUAL PROPERTY IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY THE OWNER OF THE INTELLECTUAL PROPERTY.
ROOF GARDEN 020
4. USE OF ALL CONSTRUCTION MATERIALS AND INSTALLATIONS PROPOSED SHALL CONFORM TO THE IRC 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURER’S STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
196 SF
13'-7 5/16"
ADAPTIVE TRANSFORMATION 7+,5' )/225 3/$1
AT 3.05
DETAIL 1. TYPICAL WALL TO FLOOR SECTION ´ ¶ C101012415-00
0612101001-10
0725101004-80
B201015004-00
C302041005-00 0616231000-11 11"
B101026128-00
DETAIL 2. DESIGN WALL TO FLOOR SECTION ´ ¶ C101014403-45
C101012415-00
0612101001-10
0725101004-80
0746331040-45
C302041005-00 0616231000-11
11"
B101026128-00
2"
AT 3.06
ADAPTIVE Transformation :$// 72 )/225 6(&7,21
DETAIL 3. BASEMENT WALL TO FIRST FLOOR SECTION ´ ¶
ACTION UPTOWN: 2FILL
ARC48_550
GENERAL NOTES 1. THESE DOCUMENTS ARE THE COPYRIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE URBAN DESIGN BUILD STUDIO. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AND AS STIPULATED ON SHEET IN1.00. THIS RESTRICTION AND OWNERSHIP OF INTELLECTUAL PROPERTY GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE LETTERHEAD ISSUED BY THE DIRECTOR OF THE URBAN DESIGN BUILD STUDIO.
1" 62
C101014403-45 C101012415-00
0612101001-10 0725101004-80
0746331040-45 C302041005-00 0616231000-11
7"
0612101001-10
2. NONE OF THE DOCUMENTS INCLUDED IN THE DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR PRE-CONSTRUCTION ANALYSIS SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “IN” AND “CA” SERIES (GOVERNING USE STIPULATIONS AND CODE ANALYSIS) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH CONTRACTS AND/OR PROCUREMENT. GOVERNING USE STIPULATION SHEETS AND CODE ANALYSIS (“IN” AND “CA” SERIES DOCUMENTS) PROVIDE CODE, PROCEDURAL, AND USE GUIDELINES GOVERNING ALL INFORMATION CONTAINED WITHIN THE DOCUMENTS. ANY AND ALL ENTITIES REFERENCING CONTENT INCLUDED SHALL DO SO ONLY IN THE CONTEXT OF THE ENTIRE VOLUME. NEITHER THE OWNER OF THE INTELLECTUAL PROPERTY NOR THEIR AGENTS ASSUME RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE DOCUMENTS. 3.DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED ENTITIES UTILIZING THE DOCUMENTS SHALL CONTACT OWNER OF INTELLECTUAL PROPERTY IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY THE OWNER OF THE INTELLECTUAL PROPERTY.
DETAIL 4. TYPICAL FLOOR SECTION ´ ¶ C302041005-00 0616231000-11
B101026128-00
4. USE OF ALL CONSTRUCTION MATERIALS AND INSTALLATIONS PROPOSED SHALL CONFORM TO THE IRC 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURER’S STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH. KEY NOTES 1. ALL GYPSUM WALL FINISHES ARE LEVEL 4 UNLESS WITH A BATTEN SYSTEM. 2. WHEN BATTENS ARE USED, GYPSUM WALLS ARE MINIMUM LEVEL 3 FINISH 3. BUILDING WRAP WRAPS AROUND THE TOP PLATE OF THE BASEMENT WALL 4. ALL 2X2 BATTENS ARE SPACED 24” O.C. 5. ALL 2X10 FLOOR JOISTS ARE SPACED 24” O.C.
DETAIL 5. TYPICAL FLOOR TO INTERIOR WALL SECTION ´ ¶ 0616361006-03
C101012415-00
0922362336-01 B201012921-00
B101021610-00
MATERIAL ASSEMBLY B101026128-00 - 2”X10” FLOOR JOIST, 24” O.C. B101021610-00 - 2”X4”, 24” O.C. B201012921-00 - BRICK VENEER/WOOD STUD BACKUP C101012415-00 - 1/2” GYPSUM WALL BOARD, LEVEL 4 FINISH C101014403-45 - 2”X2” BATTEN C3020410050-00 - WOOD COMPOSITE FLOORING 06012101001-10 - 6.5” SIP WALL 0725101004-80 - POLYPROPYLENE EXTERIOR HOUSE WRAP 0616231000-11 - 1/2” CDX PLYWOOD SUB FLOORING 0746331040-45 - SMOOTH TEXTURE VINYL SIDING, DOUBLE 4”
C302041005-00 0616231000-11
B101026128-00
ADAPTIVE TRANSFORMATION :$// 72 )/225 6(&7,21
AT 3.07
DETAIL 1. SE CORNER WALL PLAN ´ ¶
DETAIL 2. SW CORNER WALL PLAN ´ ¶ B201012921-00
B201012921-00
0922362336-01
0922362336-01
0612101001-10
0612101001-10
C101012415-00
C101012415-00
DETAIL 3. NE CORNER WALL PLAN ´ ¶
DETAIL 4. NW CORNER WALL PLAN ´ ¶
B201012921-00
C101012415-00
C101012415-00
0612101001-10
0612101001-10
51" 2
6"
6 1" 2
B201015004-00
AT 3.08
ADAPTIVE Transformation &251(5 '(7$,/ 3/$1
B201015004-00
DETAIL 5. SIP WALL TO INTERIOR WALL DETAIL PLAN ´ ¶
ACTION UPTOWN: 2FILL
ARC48_550
C101012415-00
0612101001-10 0725101004-80
0746331040-45
C101012415-00
B101021610-00 0922362336-01
B201012921-00
GENERAL NOTES 1. THESE DOCUMENTS ARE THE COPYRIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE URBAN DESIGN BUILD STUDIO. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AND AS STIPULATED ON SHEET IN1.00. THIS RESTRICTION AND OWNERSHIP OF INTELLECTUAL PROPERTY GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE LETTERHEAD ISSUED BY THE DIRECTOR OF THE URBAN DESIGN BUILD STUDIO. 2. NONE OF THE DOCUMENTS INCLUDED IN THE DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR PRE-CONSTRUCTION ANALYSIS SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “IN” AND “CA” SERIES (GOVERNING USE STIPULATIONS AND CODE ANALYSIS) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH CONTRACTS AND/OR PROCUREMENT. GOVERNING USE STIPULATION SHEETS AND CODE ANALYSIS (“IN” AND “CA” SERIES DOCUMENTS) PROVIDE CODE, PROCEDURAL, AND USE GUIDELINES GOVERNING ALL INFORMATION CONTAINED WITHIN THE DOCUMENTS. ANY AND ALL ENTITIES REFERENCING CONTENT INCLUDED SHALL DO SO ONLY IN THE CONTEXT OF THE ENTIRE VOLUME. NEITHER THE OWNER OF THE INTELLECTUAL PROPERTY NOR THEIR AGENTS ASSUME RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE DOCUMENTS. 3.DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED ENTITIES UTILIZING THE DOCUMENTS SHALL CONTACT OWNER OF INTELLECTUAL PROPERTY IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY THE OWNER OF THE INTELLECTUAL PROPERTY.
DETAIL 6. INTERIOR WALL DETAIL PLAN
4. USE OF ALL CONSTRUCTION MATERIALS AND INSTALLATIONS PROPOSED SHALL CONFORM TO THE IRC 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURER’S STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH. C101012415-00
B101021610-00
KEY NOTES 1. ALL GYPSUM WALL FINISHES ARE LEVEL 4 FINISHES EXCEPT WHEN BATTENS ARE USED 2. AT THE CORNER WHERE CEDAR SIDING MEETS BRICK VENEER, CEDAR SIDING MUST OVERLAP BRICK VENEER BY 6 INCHES 3. ALL INTERIOR WALL STUDS ARE SPACED AT 24”O.C. MATERIAL ASSEMBLY B201012921-00 - BRICK VENEER/WOOD STUD BACKUP B201015004-00 - WOOD EXTERIOR SIDING B101021610-00 - 2”X4”, 24” O.C. C101012415-00 - 1/2” GYPSUM WALL BOARD, LEVEL 4 FINISH 0922362336-01 - METAL LATH ON WOOD FRAMING 0612101001-10 - 6.5” SIP WALL 0725101004-80 - POLYPROPYLENE EXTERIOR HOUSE WRAP 0746331040-45 - SMOOTH TEXTURE VINYL SIDING, DOUBLE 4” 0616361006-03 - 1/2” CDX PLYWOOD SHEATHING
0616361006-03
0922362336-01 B201012921-00
ADAPTIVE TRANSFORMATION :$// 3/$1
AT 3.09
GENERAL NOTES 1. THESE DOCUMENTS ARE THE COPYRIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE URBAN DESIGN BUILD STUDIO. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AND AS STIPULATED ON SHEET IN1.00. THIS RESTRICTION AND OWNERSHIP OF INTELLECTUAL PROPERTY GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE LETTERHEAD ISSUED BY THE DIRECTOR OF THE URBAN DESIGN BUILD STUDIO. 2. NONE OF THE DOCUMENTS INCLUDED IN THE DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR PRE-CONSTRUCTION ANALYSIS SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “IN” AND “CA” SERIES (GOVERNING USE STIPULATIONS AND CODE ANALYSIS) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH CONTRACTS AND/OR PROCUREMENT. GOVERNING USE STIPULATION SHEETS AND CODE ANALYSIS (“IN” AND “CA” SERIES DOCUMENTS) PROVIDE CODE, PROCEDURAL, AND USE GUIDELINES GOVERNING ALL INFORMATION CONTAINED WITHIN THE DOCUMENTS. ANY AND ALL ENTITIES REFERENCING CONTENT INCLUDED SHALL DO SO ONLY IN THE CONTEXT OF THE ENTIRE VOLUME. NEITHER THE OWNER OF THE INTELLECTUAL PROPERTY NOR THEIR AGENTS ASSUME RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE DOCUMENTS. 3.DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED ENTITIES UTILIZING THE DOCUMENTS SHALL CONTACT OWNER OF INTELLECTUAL PROPERTY IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY THE OWNER OF THE INTELLECTUAL PROPERTY. 4. USE OF ALL CONSTRUCTION MATERIALS AND INSTALLATIONS PROPOSED SHALL CONFORM TO THE IRC 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURER’S STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
DETAIL 1. TYPICAL WALL DETAIL AXON ´ ¶
DETAIL 2. TYPICAL WALL DETAIL PLAN ´ ¶ 0746331040-45
0746331040-45
0725101004-80
0725101004-80
0612101001-10
0612101001-10
B101026124-00
B101026124-00
1" 62
1" 62
C101012415-00 C101012415-00
1'
AT 3.10
ADAPTIVE Transformation 7<3,&$/ :$// &216758&7,21 '(7$,/
1'
ACTION UPTOWN: 2FILL
KEY NOTES 1. ALL GYPSUM WALL FINISHES ARE LEVEL 4 FINISHES EXCEPT WHEN BATTENS ARE USED. 2. WHEN BATTENS ARE USED, GYPSUM WALL FINISHES ARE MINIMUM LEVEL 3 FINISH. 3. ON A TYPICAL WALL, GYPSUM BOARDS MUST BE INSTALLED STAGGERED MINIMUM 1 FT FROM THE SIP WALL JOINTS. 4. ALL 2X2 BATTENS ARE SPACED AT 24” O.C. MATERIAL ASSEMBLY B201012921-00 - BRICK VENEER/WOOD STUD BACKUP B101026124-00 - 2”X6”, 48” O.C. C101012415-00 - 1/2” GYPSUM WALL BOARD, LEVEL 4 FINISH C101014403-45 - 2”X2” BATTEN 0612101001-10 - 6.5” SIP WALL 0725101004-80 - POLYPROPYLENE EXTERIOR HOUSE WRAP 0746331040-45 - SMOOTH TEXTURE VINYL SIDING, DOUBLE 4” 0616361006-03 - 1/2” CDX PLYWOOD SHEATHING
ARC48_550
DETAIL 4. DESIGN WALL DETAIL PLAN ´ ¶ 6 1" 2
6 1" 2
DETAIL 3. DESIGN WALL DETAIL AXON ´ ¶
0746331040-45 0725101004-80 0746331040-45 0725101004-80
B101026124-00
B101026124-00 0612101001-10
0612101001-10 C101012415-00
C101012415-00 C101014403-45
C101014403-45
4'
4'
2'
2' 2" 2" 2" 2"
ADAPTIVE TRANSFORMATION '(6,*1 :$// &216758&7,21 '(7$,/
AT 3.11
0731131002-05
DETAIL 1. ROOF TO WALL DETAIL SECTION ´ ¶
0731131008-25
0612101002-10
B101026124-00
B201012921-00
0922362336-01
DETAIL 2. ROOF PEAK DETAIL SECTION ´ ¶ 0725101004-80
0731131002-05
0731131008-25
0612101001-10
C101012415-00
0612101002-10
B101026124-00
AT 3.12
ADAPTIVE Transformation :$// 72 522) 6(&7,21
ACTION UPTOWN: 2FILL
ARC48_550
GENERAL NOTES 1. THESE DOCUMENTS ARE THE COPYRIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE URBAN DESIGN BUILD STUDIO. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AND AS STIPULATED ON SHEET IN1.00. THIS RESTRICTION AND OWNERSHIP OF INTELLECTUAL PROPERTY GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE LETTERHEAD ISSUED BY THE DIRECTOR OF THE URBAN DESIGN BUILD STUDIO. 2. NONE OF THE DOCUMENTS INCLUDED IN THE DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR PRE-CONSTRUCTION ANALYSIS SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “IN” AND “CA” SERIES (GOVERNING USE STIPULATIONS AND CODE ANALYSIS) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH CONTRACTS AND/OR PROCUREMENT. GOVERNING USE STIPULATION SHEETS AND CODE ANALYSIS (“IN” AND “CA” SERIES DOCUMENTS) PROVIDE CODE, PROCEDURAL, AND USE GUIDELINES GOVERNING ALL INFORMATION CONTAINED WITHIN THE DOCUMENTS. ANY AND ALL ENTITIES REFERENCING CONTENT INCLUDED SHALL DO SO ONLY IN THE CONTEXT OF THE ENTIRE VOLUME. NEITHER THE OWNER OF THE INTELLECTUAL PROPERTY NOR THEIR AGENTS ASSUME RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE DOCUMENTS. 3.DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED ENTITIES UTILIZING THE DOCUMENTS SHALL CONTACT OWNER OF INTELLECTUAL PROPERTY IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY THE OWNER OF THE INTELLECTUAL PROPERTY. 4. USE OF ALL CONSTRUCTION MATERIALS AND INSTALLATIONS PROPOSED SHALL CONFORM TO THE IRC 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURER’S STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH. KEY NOTES 1. 2X6 ROOF RAFTERS SPACED AT 48” O.C. MATERIAL ASSEMBLY B101026124-00 - 2”X6” ROOF JOIST, 48” O.C. B201012921-00 - BRICK VENEER/WOOD STUD BACKUP C101012415-00 - 1/2” GYPSUM WALL BOARD, LEVEL 4 FINISH 0612101002-10 - 8.25” SIP ROOF 06012101001-10 - 6.5” SIP WALL 0922362336-01 - METAL LATH ON WOOD FRAMING 0725101004-80 - POLYPROPYLENE EXTERIOR HOUSE WRAP 0731131002-05 - ASPHALT SHINGLES 0731131008-25 - #30 FELT UNDERLAYMENT
ADAPTIVE TRANSFORMATION 522) '(7$,/ 6(&7,21
AT 3.13
DETAIL 1. MANSARD ROOF DETAIL SECTION ´ ¶
0731131002-05
0731131008-25
0612101002-10
B101026124-00
0792132000-50
0928131001-70
C302041016-00
AT 3.14
ADAPTIVE Transformation 0$16$5' 522) 6(&7,21
ACTION UPTOWN: 2FILL
DETAIL 2. THIRD FLOOR BATHROOM WALL SECTION ´ ¶ 0731131002-05
0731131008-25
0612101002-10
0928131001-70
C302041016-00
B101021610-00
ARC48_550
GENERAL NOTES 1. THESE DOCUMENTS ARE THE COPYRIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE URBAN DESIGN BUILD STUDIO. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AND AS STIPULATED ON SHEET IN1.00. THIS RESTRICTION AND OWNERSHIP OF INTELLECTUAL PROPERTY GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE LETTERHEAD ISSUED BY THE DIRECTOR OF THE URBAN DESIGN BUILD STUDIO. 2. NONE OF THE DOCUMENTS INCLUDED IN THE DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR PRE-CONSTRUCTION ANALYSIS SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “IN” AND “CA” SERIES (GOVERNING USE STIPULATIONS AND CODE ANALYSIS) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH CONTRACTS AND/OR PROCUREMENT. GOVERNING USE STIPULATION SHEETS AND CODE ANALYSIS (“IN” AND “CA” SERIES DOCUMENTS) PROVIDE CODE, PROCEDURAL, AND USE GUIDELINES GOVERNING ALL INFORMATION CONTAINED WITHIN THE DOCUMENTS. ANY AND ALL ENTITIES REFERENCING CONTENT INCLUDED SHALL DO SO ONLY IN THE CONTEXT OF THE ENTIRE VOLUME. NEITHER THE OWNER OF THE INTELLECTUAL PROPERTY NOR THEIR AGENTS ASSUME RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE DOCUMENTS. 3.DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED ENTITIES UTILIZING THE DOCUMENTS SHALL CONTACT OWNER OF INTELLECTUAL PROPERTY IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY THE OWNER OF THE INTELLECTUAL PROPERTY.
2241191020-00
4. USE OF ALL CONSTRUCTION MATERIALS AND INSTALLATIONS PROPOSED SHALL CONFORM TO THE IRC 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURER’S STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH. B101026128-00
KEY NOTES 1. 2X6 ROOF RAFTERS SPACED AT 48” O.C.
C101012415-00
0612101001-10
B201015004-00 0725101004-80
MATERIAL ASSEMBLY B101021610-00 - 2”X4” B101026124-00 - 2”X6” ROOF JOIST, 48” O.C. B101026128-00 - 2”X10”, 24” O.C. B201012921-00 - BRICK VENEER/WOOD STUD BACKUP B201015004-00 - WOOD EXTERIOR SIDING C101012415-00 - 1/2” GYPSUM WALL BOARD, LEVEL 4 FINISH C302041016-00 - VINYL TILE 09283131001-70 - CEMENT BACKER BOARD 1/2” THICK 0612101002-10 - 8.25” SIP ROOF 06012101001-10 - 6.5” SIP WALL 0922362336-01 - METAL LATH ON WOOD FRAMING 0725101004-80 - POLYPROPYLENE EXTERIOR HOUSE WRAP 0731131002-05 - ASPHALT SHINGLES 0731131008-25 - #30 FELT UNDERLAYMENT 0792132000-50 - SIP JOINT SEALANT 2241191020-00 - BATH TUB, ENAMELED FORMED STEEL
ADAPTIVE TRANSFORMATION 7+,5' )/225 %$7+5220 6(&7,21
AT 3.15
DETAIL 1. ROOF TERRACE TO WALL DETAIL SECTION ´ ¶
C101014403-45
C101012415-00
0612101001-10
0922362336-01 0923131003-01
0615161016-02
C101012805-40
B101026128-00
AT 3.16
B101026128-00
ADAPTIVE Transformation 522) 7(55$&( :$// 6(&7,21
ACTION UPTOWN: 2FILL
ARC48_550
GENERAL NOTES 1. THESE DOCUMENTS ARE THE COPYRIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE URBAN DESIGN BUILD STUDIO. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AND AS STIPULATED ON SHEET IN1.00. THIS RESTRICTION AND OWNERSHIP OF INTELLECTUAL PROPERTY GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE LETTERHEAD ISSUED BY THE DIRECTOR OF THE URBAN DESIGN BUILD STUDIO. 2. NONE OF THE DOCUMENTS INCLUDED IN THE DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR PRE-CONSTRUCTION ANALYSIS SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “IN” AND “CA” SERIES (GOVERNING USE STIPULATIONS AND CODE ANALYSIS) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH CONTRACTS AND/OR PROCUREMENT. GOVERNING USE STIPULATION SHEETS AND CODE ANALYSIS (“IN” AND “CA” SERIES DOCUMENTS) PROVIDE CODE, PROCEDURAL, AND USE GUIDELINES GOVERNING ALL INFORMATION CONTAINED WITHIN THE DOCUMENTS. ANY AND ALL ENTITIES REFERENCING CONTENT INCLUDED SHALL DO SO ONLY IN THE CONTEXT OF THE ENTIRE VOLUME. NEITHER THE OWNER OF THE INTELLECTUAL PROPERTY NOR THEIR AGENTS ASSUME RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE DOCUMENTS. 3.DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED ENTITIES UTILIZING THE DOCUMENTS SHALL CONTACT OWNER OF INTELLECTUAL PROPERTY IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY THE OWNER OF THE INTELLECTUAL PROPERTY. 4. USE OF ALL CONSTRUCTION MATERIALS AND INSTALLATIONS PROPOSED SHALL CONFORM TO THE IRC 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURER’S STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH. KEY NOTES 1. ALL GYPSUM WALL FINISHES ARE LEVEL 4 FINISHES EXCEPT WHEN BATTENS ARE USED. 2. WHEN BATTENS ARE USED, GYPSUM WALL FINISHES ARE MINIMUM LEVEL 3 FINISH. 3. ALL 2X2 BATTENS ARE SPACED AT 24” O.C. 4. 2X10 FLOOR JOISTS ARE SPACED AT 24” O.C. MATERIAL ASSEMBLY B101026128-00 - 2”X10”, 24” O.C. C101012805-40 - BASE PLATE/TOP PLATE FOR SIP 2”X6” C101012415-00 - 1/2” GYPSUM WALL BOARD, LEVEL 4 FINISH C101014403-45 - 2”X2” BATTEN, 24” O.C. 0612101002-10 - 8.25” SIP ROOF 06012101001-10 - 6.5” SIP WALL 0725101004-80 - POLYPROPYLENE EXTERIOR HOUSE WRAP 0615161016-02 - 1”X8” WOOD ROOF DECKING 0923131003-01 - PERLITE PLASTER, 2 COATS 0922362336-01 - METAL LATH ON WOOD FRAMING
ADAPTIVE TRANSFORMATION 522) 7(55$&( :$// 6(&7,21
AT 3.17
0731131002-05
DETAIL 1. ROOF PEAK FLASHING DETAIL SECTION ´ ¶
0765101000-30 0731131008-25
0612101002-10 C101012805-40
0731131002-05
DETAIL 2. SOUTHERN ROOF EDGE FLASHING DETAIL SECTION ´ ¶
0765101000-30 0731131008-25
0771233000-12
0612101002-10
AT 3.18
C101012805-40
ADAPTIVE Transformation )/$6+,1* '(7$,/
ACTION UPTOWN: 2FILL
DETAIL 3. NORTHERN ROOF EDGE FLASHING DETAIL SECTION ´ ¶
0612101002-10
ARC48_550
GENERAL NOTES 1. THESE DOCUMENTS ARE THE COPYRIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE URBAN DESIGN BUILD STUDIO. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AND AS STIPULATED ON SHEET IN1.00. THIS RESTRICTION AND OWNERSHIP OF INTELLECTUAL PROPERTY GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY SCHOOL OF ARCHITECTURE LETTERHEAD ISSUED BY THE DIRECTOR OF THE URBAN DESIGN BUILD STUDIO. 2. NONE OF THE DOCUMENTS INCLUDED IN THE DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR PRE-CONSTRUCTION ANALYSIS SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “IN” AND “CA” SERIES (GOVERNING USE STIPULATIONS AND CODE ANALYSIS) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH CONTRACTS AND/OR PROCUREMENT. GOVERNING USE STIPULATION SHEETS AND CODE ANALYSIS (“IN” AND “CA” SERIES DOCUMENTS) PROVIDE CODE, PROCEDURAL, AND USE GUIDELINES GOVERNING ALL INFORMATION CONTAINED WITHIN THE DOCUMENTS. ANY AND ALL ENTITIES REFERENCING CONTENT INCLUDED SHALL DO SO ONLY IN THE CONTEXT OF THE ENTIRE VOLUME. NEITHER THE OWNER OF THE INTELLECTUAL PROPERTY NOR THEIR AGENTS ASSUME RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE DOCUMENTS.
0731131002-05
0731131008-25
0765101000-30
3.DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED ENTITIES UTILIZING THE DOCUMENTS SHALL CONTACT OWNER OF INTELLECTUAL PROPERTY IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY THE OWNER OF THE INTELLECTUAL PROPERTY. 4. USE OF ALL CONSTRUCTION MATERIALS AND INSTALLATIONS PROPOSED SHALL CONFORM TO THE IRC 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURER’S STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH. MATERIAL ASSEMBLY B201015004-00 - WOOD EXTERIOR SIDING C101012805-40 - BASE PLATE/TOP PLATE FOR SIP 2”X” 0612101002-10 - 8.25” SIP ROOF 06012101001-10 - 6.5” SIP WALL 072510100480 - POLYPROPYLENE EXTERIOR HOUSE WRAP 0731131002-05 - ASPHALT SHINGLES 0731131008-25 - #30 FELT UNDERLAYMENT 0765101000-30 - ALUMINUM SHEET METAL FLASHING 0771233000-12 - ALUMINUM GUTTERS
0771233000-12 B201015004-00 0725101004-80
0612101001-10
ADAPTIVE TRANSFORMATION )/$6+,1* '(7$,/
AT 3.19
ASSEMBLY
SEQUENCE
SELECTIVE DEMOLITION 1
5HPRYH )URQWDO 0HWDO &KDLQ )HQFH :KDW Remove the metal chain fence that is dividing the parking spaces on Lot 157 from the private garden in the back. +RZ First drill the pavement around fenceâ&#x20AC;&#x2122;s perimeter and then uproot it. A crew of two people is needed to accom plish this task. :KHUH Load metal chain fence onto a small truck and take it to a metal recycling plant such as Three Rivers Scrap Metal in Pittsburgh.
2
5HPRYH %DFN :RRG )HQFH :KDW Remove dilapidated wood fence that is located in the rear end of Lot 157. The wood fence does not follow the lot boundary line, and is cutting the square area of the lot. +RZ First dig a small trench around the perimeter of the fence, and then uproot the wood planks from the ground. This task can be accomplished by two workers quickly. :KHUH Load wood planks and donate them to Lumberjack Tree Services INC. which will convert the scarp wood into mulch, or wood chips for future reuse.
3
Relocate Wood Steps :KDW Relocate wood steps that lead up to the back porch of the adjacent lot, but are located inside the boundary of Lot 157. The steps can be shifted to the southern side of the porch. +RZ Drill around the thin concrete layer around the steps. Then dig a shallow surface on the right location, pour FRQFUHWH DQG ÂżQDOO\ DWWDFK ZRRGHQ VWHSV WR WKH VKDOORZ IRXQGDWLRQ :KHUH Load metal chain fence onto a small truck and take it to a metal recycling plant such as Three Rivers Scrap Metal in Pittsburgh.
4
&XW 'RZQ %DFN 3RUFK $UHD :KDW Part of the neighbors back wooden porch lies withing the boundary of LOT 157. The Porch must be removed in order to construct the new house. +RZ That portion of the back porch can be sawed of by a crew of two men. They must ensure that new wood batons DUH SODFHG XQGHUQHDWK WKH UHPDLQLQJ SRUFKÂśV VXUIDFH WR KDYH VXIÂżFLHQW VWUXFWXUDO VXSSRUW :KHUH: These wood planks can also be donated to Lumberjack Tree Services INC.
5
8SOLIW 3DUNLQJ /RW 3DYHPHQW :KDW Remove concrete pavement that is used for two parking spaces and is facing Forbes Avenue. +RZ Use a jackhammer to drill concrete surface, remove any rebar and sub grade gravel. :KHUH /RDG UXEELVK LQWR D VPDOO SLFNXS WUXFN DQG WDNH WR 5HVHUYH 3DUN /DQGÂżOO
6
8SOLIW 3DYHPHQW 3DWK :KDW Remove concrete path that connect the parking spaces to the back porch wooden stairs. How: Use a jackhammer to drill concrete surface, remove any rebar and sub grade gravel. :KHUH /RDG UXEELVK LQWR D VPDOO SLFNXS WUXFN DQG WDNH WR 5HVHUYH 3DUN /DQGÂżOO
SD 1.00
SELECTIVE DEMOLITION 6(48(1&(
ACTION UPTOWN: 2FILL
Before Demolition
ARC48_550
After Demolition
After demolition Lot 157 opens up, its footprint relates to the lot boundary, there are no encroaching elements from the neighborâ&#x20AC;&#x2122;s property, and the excavation is ready to begin.
SELECTIVE DEMOLITION 6(48(1&(
SD 1.01
ASSEMBLY SEQUENCE Overall assembly order on 1.00 and 1.01 correlate to GHWDLOHG DVVHPEO\ VHTXHQFHV RQ
pour basement ZDOOV
a
1 2
LQVWDOO ¿UVW VWRU\ 6,3 ÀRRU
3 c
HUHFW ¿UVW VWRU\ 6,3 ZDOO SDQHOV RQ north and south sides
e,f
HUHFW QRUWKZHVW H[WHULRU ZDOO
e,f
AS 1.00
d
OD\ ÀRRU RQ WRS RI joists
6 7
d
b
HUHFW ¿UVW VWRU\ 6,3 ZDOO SDQHOV DJDLQVW DGMDFHQW EXLOGLQJV RQ HDVW DQG ZHVW sides
SXW XS ÀRRU joists for second story
erect second VWRU\ 6,3 ZDOOV RQ HDVW DQG ZHVW sides
8
c
4
9 HUHFW QRUWKZHVW H[WHULRU ZDOO
e,f
5
10 erect second VWRU\ 6,3 SDQHOV LQ QRUWKZHVW corner
e,f
ASSEMBLY SEQUENCE 3,&725,$/ '(3,&7,21 2) 67$*(' ,03/(0(17$7,21
ACTION UPTOWN: 2FILL
OD\ MRLVWV IRU third story
d
OD\ ÀRRU IRU WKLUG
d
erect third story 6,3 SDQHOV RQ HDVW DQG ZHVW sides
11 12 13
ARC48_550
16
OD\ URRI RQ WRS RI joists
g
17
LQWHULRU ZDOOV LQVWDOOHG
c,e
18
ZLQGRZV DQG GRRUV LQVWDOOHG DQG VHDOHG
e
14
19 H[WHULRU ¿QLVKHV LQVWDOOHG
erect third story 6,3 SDQHOV RQ north facade
f
e,f
15 put up roof joists on third story
g,f
ASSEMBLY SEQUENCE 3,&725,$/ '(3,&7,21 2) 67$*(' ,03/(0(17$7,21
AS 1.01
ASSEMBLY SEQUENCE 7KH DVVHPEO\ VHTXHQFH VHULHV LV LQWHQGHG WR JLYH D WKRURXJK XQGHUVWDQGLQJ RI KRZ WKH HQWLUH EXLOGLQJ LV SXW WRJHWKHU XWLOL]LQJ VSHFL¿ F PD terials and components. The sequence is lettered and numbered in the order of construction. The diagramatic depiction of the assembly sequence are intended to act as diagrams as they only represent a small portion of the total construction of the building.
a
Basement
3 LQVHUW DQFKRU EROWV 2 pour concrete 1 SO\ZRRG IUDPLQJ
remove after concrete has set
b
SIP Floor QDLO LQ SODFH SODFH ULP MRLVW OD\ 6,3 À RRU LQ ( : GLUHFWLRQ
VFUHZ DQFKRU QXWV LQ SODFH OD\ VLOO SODWHV
AS 1.02
ASSEMBLY SEQUENCE 3,&725,$/ '(3,&7,21 2) 67$*(' ,03/(0(17$7,21
5 4 3 2 1
ACTION UPTOWN: 2FILL
c
'HVLJQ :DOO
8 SODFH ULP MRLVWV 7 QDLO 6,3 WR WRS SODWH 6 QDLO 6,3 WR WRS SODWH 5 OD\ WRS SODWH 4 QDLO 6,3 WR VLOO SODWH 3 HUHFW 6,3 ZDOOV 2 QDLO LQ SODFH 1 OD\ VLOO SODWH
d
ARC48_550
10 DWWDFK GU\ZDOO 9
LI GHVLJQ ZDOO attach battens
Floor
5 QDLO 26% LQ SODFH 4 OD\ 26% À RRULQJ 3 QDLO LQ SODFH 2 KDQJ MRLVWV 1 LQVWDOO MRLVW KDQJHUV
ASSEMBLY SEQUENCE 3,&725,$/ '(3,&7,21 2) 67$*(' ,03/(0(17$7,21
AS 1.03
ASSEMBLY SEQUENCE
e
Wall
5 OD\ À RRULQJ 4 DWWDFK GU\ZDOO 3 QDLO LQ SODFH 2 HUHFW 6,3 ZDOOV 1 OD\ VLOO SODWH
f
([WHULRU :DOO
2 DWWDFK H[WHULRU FODGGLQJ 1 ZUDS YDSRU EDUULHU
AS 1.04
ASSEMBLY SEQUENCE 3,&725,$/ '(3,&7,21 2) &5,7,&$/ 3$,5,1*6
ACTION UPTOWN: 2FILL
g
ARC48_550
Roof
9 DSSO\ DVSKDOW VKLQJOHV 8 OD\ URR多 QJ IHOW 7 QDLO 6,3V LQ SODFH 6 insert fascia 5 OD\ 6,3 URRI 4 attach roof joists 3 SODFH ULP MRLVW 2 QDLO LQ SODFH 1 OD\ VLOO SODWH
ASSEMBLY SEQUENCE 3,&725,$/ '(3,&7,21 2) &5,7,&$/ 3$,5,1*6
AS 1.05
EXTERIOR PERSPECTIVE
AS 1.06
ASSEMBLY SEQUENCE (;7(5,25 3(563(&7,9(
ACTION UPTOWN: 2FILL
ARC48_550
3HUVSHFWLYH ORRNLQJ 6RXWK )URP )RUEHV $YHQXH There were many consideration taken into account for the materiality and the form of the project. Despite being affordable housing, many decisions were made to create an attractive housing. At the same time, the house could not deviate too much from the materialities and typologies around the project site. The project uses mansard roof that is seen in many building around the site as well as a dormer window. However, dormer window is reinterpreted in a modern way. The facade also shows a subtle division EHWZHHQ WKH ÂżUVW Ă&#x20AC;RRU DQG WKH UHVW RI WKH Ă&#x20AC;RRUV KLQWLQJ DW WKH IDFW WKDW WKHUH DUH WZR GLIIHUHQW RFFXSDQWV in the house. By using cost saving construction methods such as Structure Insulated Panels, wood siding can be employed in chosen areas such as the front facade., while vertical circulation and service FRUULUGRUV DUH ÂżQLVKHG ZLWK EULFN YHQHHU 7KH )RUEHV $YHQXH IDFDGH WKXV KDV WZR PDLQ PDWHULDOV RI ZRRG siding and brick veneer, two materials that are complementary of each other. The resulting design has found a balance between modernism unseen around the site and existing typologies.
ASSEMBLY SEQUENCE (;7(5,25 3(563(&7,9(
AS 1.07
EXTERIOR PERSPECTIVE
AS 1.08
ASSEMBLY SEQUENCE (;7(5,25 3(563(&7,9(
ACTION UPTOWN: 2FILL
Perspective looking North from Community Garden
ARC48_550
INTERIOR PERSPECTIVE
AS 1.09
ASSEMBLY SEQUENCE ,17(5,25 3(563(&7,9(
ACTION UPTOWN: 2FILL
3HUVSHFWLYH 9LHZ RI )LUVW )ORRU $SDUWPHQW
ARC48_550
INTERIOR PERSPECTIVE
AS 1.10
ASSEMBLY SEQUENCE ,17(5,25 3(563(&7,9(
ACTION UPTOWN: 2FILL
ARC48_550
3HUVSHFWLYH 9LHZ RI 2ZQHU¶V $SDUWPHQW 6HFRQG )ORRU /LYLQJ 5RRP
IMPLEME
ENTATION
IMPLEMENTATION METHODOLOGY +RZ WR XVH WKH ,PSOHPHQWDWLRQ 'RFXPHQWV The Implementation (IMP) series of documents are meant to serve as a guide and reference point for all parties involved in the project. These documents delineate the logistics, cost estimates based on construction building elements, and a critical path based on the main activities in the project. These documents can be used by the project owner to understand the project more in depth, have an expectation of the projectâ&#x20AC;&#x2122;s cost, and know where in the process the project should be at any given time. It is expected that the contract creates a more detailed cost estimate based on a quantity survey analysis of the project, and uses the cost estimates provided in the IMP section as a gage to compare the values.
'HVLJQ %LG %XLOG &RQWUDFW $ 'HVLJQ %LG %XLOG FRQWUDFW LV WKH EHVW ÂżW IRU WKLV SURMHFW 6RPH RI WKH PDMRU SRLQWV LQ WKLV FRQWUDFW W\SH DUH
An offer to bid will be set forth for parties interested to construct the project. A bidding bond will be required by participating parties. A bid many not be withdrawn for a period of 35 days after time has been called on the date of opening except in accordance with the provisions of Pennsylvania law. 7KH 2ZQHU UHVHUYHV WKH IXOO ULJKW WR GHWHUPLQH WKH ELG ZLQQHU EDVHG RQ WKH ORZHVW ELG DQG TXDOLÂżFDWLRQV The Owner reserves the right either to supplement the budget or to negotiate with the lowest responsive and responsible bidder. But only for the purpose of making changes to the project that will result in a cost to the Owner that is within the budgeted, as it may be supplemented. The Contract, if awarded will be on a lump sump basis. The Contractor will perform all the work required by the Contract documents. The Contractor will create a detailed schedule for the completion and progress of the project. The payment method will be periodic progress payments. The owner will make progress payments, less retainer of 10%, as the project advances. )LQDO SD\PHQW ZLOO EH PDGH ZLWKLQ WHQ GD\V RI WKH UHFHLSW RI WKH ÂżQDO SD\PHQW DSSOLFDWLRQ SURYLGHG DOO RWKHU UH quirements of the Contract are met in their full extent and scope. The Contractor will provide both performance and payment bonds and will pay the premiums thereon as a Cost of Work. Full performance: The Owner, Architect, and Contractor agree to the full performance of the Contract Documents. Applicable Law: The Contract and all its rights, privileges, and responsibilities will be interpreted and construed according to the laws of the State of Pennsylvania and the City of Pittsburgh. 0RVW IRXQGDWLRQV DQG QRQ SURÂżW IRXQGDWLRQV WKDW JLYH JUDQWV UHTXLUH D FRPSHWLWLYH ELG SURFHVV WR EH KHOG VR D GHVLJQ ELG EXLOG linear path is appropriate in this regard as well.
5LVNV DQG /LPLWDWLRQV RI &RVW (VWLPDWHV DQG $FWLYLW\ 'XUDWLRQV Every project carries risks and can pose unforeseen problems and complications. Even though these documents are meant to alleviate the poten tial problems and create a clear working sequence and framework for the implementation of the project unexpected problems and changes might arise in the future. Some of the limitations of these documents are:
Material costs change quickly based on the overall health of the world economy and the price of raw commodties. This can lead to unforeseen higher costs in the project, even though we can introduced contingency percent age at different stages of the project, these additional funds might prove not to be enough. ,QFOHPHQW ZHDWKHU FDQ FDXVH VLJQLÂżFDQW SURMHFW GHOD\V DQG H[WHQVLRQV LQ WKH GXUDWLRQV RI DFWLYLWLHV
0DWHULDO 3XUFKDVHV :H DUH JRLQJ WR EX\ WKH FRQVWUXFWLRQ PDWHULDOV IRU WKH SURMHFW WKURXJK D QRQ SURÂżW RUJDQL]DWLRQ EHFDXVH WKHVH HQWLWLHV GR QRW KDYH WR SD\ D VDOHV WD[ 7KLV ZLOO VDYH D VLJQLÂżFDQW DPRXQW RI PRQH\ WKDW FDQ EH UH LQYHVWHG LQ RWKHU IDFHWV RI WKH SURMHFW VXFK DV GHVLJQ GHWDLOLQJ RU PRUH DPHQLWLHV IRU WKH UHVLGHQWV 6LQFH WKH FRQWUDFWRU ZLOO ORVH SRWHQWLDO SURÂżW EHFDXVH WKH PDWHULDOV DUH EHLQJ SXUFKDVHG E\ D QRQ SURÂżW ZH DUH FRPSHQVDWLQJ KLP RU KHU E\ LQFUHDVLQJ WKHLU SURÂżW PDUNXS VOLJKWO\
IMP 1.00
IMPLEMENTATION ,03/(0(17$7,21 0(7+2'2/2*<
LOGISTICS Logistical Steps
ACTION UPTOWN: 2FILL
ARC48_550
$SSO\ IRU %XLOGLQJ 3HUPLWV
Home Depot Grant 1. Zoning Counter 2. File Room
1
3. Engineering Counter 4. Licence & Cashier Counter 5. Land Operation Permit 6. Department of Public Words 7. Pittsburgh Water and Sewage Authority 8. Licence and Cashier Counter
2
$SSO\ IRU *UDQWV DQG /RDQV 1. Home Depot Grant 2. Choice Neighborhood Grant 3. Energy policy Act 2005 Tax Credit .H\VWRQH +(/3 (QHUJ\:RUNV (I多FLHQF\ 3URJUDP 5. Heinz Endowment 6. URA Pittsburgh Home Rehabilitation Program
3
3XUFKDVH 0DWHULDOV IRU &RQVWUXFWLRQ 5HIHU WR &6, 6SHFL多FDWLRQV IRU 0DWHULDO 3XUFKDVHV 0DWHULDOV ZLOO EH SXUFKDVHV E\ D QRQ SUR多W RUJDQL]DWLRQ OLNH $FWLRQ +RXVLQJ LQ RUGHU QRW WR SD\ VDOHV WD[HV DQG EULQJ the cost of the project down.
4
Construction Refer to construction documents and assembly sequence drawings
Inspection
5
1. Foot Inspection 2. Rough Inspection 3. Final Inspections 4. Hand over project keys to owner
2ZQHUV 0RYH LQ
6
New home owners move into the house with the help of Action Housing. Action Housing can teach residents about best management practices to maintain the house in good condition and to manage the heating and cooling loads to reduce their utility bills.
IMPLEMENTATION /2*,67,&6
IMP 1.01
POTENTIAL GRANTS AND LOANS
Action Uptown will petition for the grant money from respective foundations and government sources. Most foundations only give grants and money to large scale projects that will have a widespread impact on a community or neighborhood, instead of just one small intervention. 2QFH $FWLRQ 8SWRZQ UHFHLYHV WKH PRQH\ LW ZLOO GLVWULEXWH DQG GLYLGH LW DPRQJVW LWV FXUUHQW SURMHFWV OLNH /RW 7KH LQÂżOO W\SRORJ\ DV D ZKROH FRXOG be a recipient of part of the money. The amounts shown below is what each house project would as from Action Uptown once if has the money.
*UDQW
Home Depot Grant Grant: $2,000- $2,500
8VHV To promote green affordable housing. The grant encourages community revitalization projects to promote healthy and sustainable homes.
&KRLFH 1HLJKERUKRRGV *UDQW
*UDQW
Grant: varied range, up to 100%
Application: Used to revitalize existing housing, transform distressed neighborhoods, and relocate public housing residents into mixed in come communities. Money for homeowners or potential ones at less than 100% of the median income for a four person family home.
&RQVWUXFWLRQ ÂżQDQFLQJ IRU UHKDELOLWDWLRQ FRVWV Provision of subordinate mortgages Down payments and closing costs Demolition, abatement of toxic materials, owner relocation, site improvements, administration,marketing, and legal costs related to construction and rehabilitation.
.H\VWRQH +(/3 (QHUJ\:RUNV (IÂżFLHQF\ 3URJUDP
/RDQ
/RDQ Application: ,PSURYH HQHUJ\ HIÂżFLHQF\ E\ ÂżQDQFLQJ KLJK HIÂżFLHQF\ KHDWLQJ FRROLQJ DLU FRQGLWLRQLQJ LQVXODWLRQ ZLQGRZV DQG GRRUV Terms: All loans are unsecured with interest rates ranging from 0.99% to5.99% with a maturity of 3, 5, or 10 years.
+HLQ] )RXQGDWLRQ
*UDQW
/RDQ $50,000 Application: Support projects in southwestern PA to improve the quality of life in the region and address community based challenges. One of its main focuses is Community & Economic Development. The endowment distributes approximately $60 million annually. Terms: Project has to demonstrate it will improve the community quality of life and improve the city of Pittsburgh.
85$ 3LWWVEXUJK +RPH 5HKDELOLWDWLRQ 3URJUDP
*UDQW
Grant: UHSD\PHQW LQ \HDUV 8VHV +HOSV PDNH KRPHV PRUH HQHUJ\ HIÂżFLHQW WKURXJK ORDQV DQG JUDQWV SURJUDP 8VH PRQH\ WR SUHYHQW DLU LQÂżOWUDWLRQ LPSURYH SRRU LQVXODWLRQ and reduce air leakage through duct work.
IMP 1.03
IMPLEMENTATION *5$176 $1' /2$16
727$/
CONTRACTS
The Archite The Architect will a ct d Architect h will vismins as no it ite Will report con the sr the t tro ite C Is not re o ow AIA B101 sponsibner de l or c at inont le f vi ha te ra The Owne or ati rg rv ct ac on e Review a r and C ts s fo al nd c on or fro r erti tra omm fy cto Mantain G the r ene w am ill ral ker ’s com L ou Include s pensa iabil enginee tructu tion ity, AIA C401 ring seral, m, Pro rvi e ce c s.
s issuing ialie ec on dr inte p aw S i
The ‘Agr
ntativcet work The owneeement’ i O s r rese e w i W rep insp Furnish the ill desig dentif r ’s n to f N nat ied cont ne uctio o P CT the Ocownstrmethoed,sor dcetofer cts Throeviodwenceornwtrai ctoarctor wiethin wraits the ER l l p ayof ca ing ing con TE d breoughans osrcheeduClontra fo pa 15 w tr Arch Provid
AR CH I
r n ci e info h the an th me ct, of th rma ec ty da o ugh s e ra The own tio e to y hro t e r r s o h th ontions sa fu s as t n for ate tract c is he ry l u nic Con , Wor- Furnish t s r u u i m i g bility m to Provide rveys ht lity Lia m e ge ty to i l u l to e bil Liabi ectric Furnish le itech de co ts d ga nic sc mo al nd el ng Own n e o r t p ion l, a biddi ays l, ins al e rib Au ess ical st in for ura n f n i t o ha Ass tal n c
SU
AIA A201
tions rea rp s ng
BC Subcontra ON ctors wor Contracto n o i k t r w risdic who the Su ill notif for C al ju ies or duties b c -Con y Ow ont o l r ivit equireedd be- The Owne t e c h r can s are ner ator y t r by a vlase rinvolv o b b reje y w r A d he protim ct es ire s eit r aspt or u a S ritin rch s s u i o t o q c n , e ub g . t i s t n re atio onsal c h c me r u Co i c n A g t o d li ec itio n the tract p dd s n n it o co c to ce
ANTS T L U NS O C
o n y T h e c ontrac r will b ow thorit rights tor c e li the s au e lien or du a c t n i e en res nforc ts The cosntof the A not be ence e en we xp surveys rac d rc r t e et e e n to em ents, o r wilhl itec liev if th t b av tio agresem ed a caus t e b , o f e ac ill h rma cial s,ea c l limit larifi patest of t is lega cat w fo n al id s o i te’s e o r r c i , o t c in fina rov t h o e t n w f or so or ins b ds r fails k o n i n fil app f a ract legal ac sa d ont cc inst ion s an if c o rd ru at rk istic an oc wo cter g untin op harers cco c st d a ork e ne gi , an of w ce ost tors ontrac nd c all matters The contr act er a in
R O CT
ARC48_550
ACTION UPTOWN: 2FILL
C O NT R A
The key contracts in this project are AIA A201, AIA B101, and AIA C401.They are listed from most important to least important one. The chart above shows the most salient points in each contract, each party’s responsibilities in each one, and how they relate to one another.
IMPLEMENTATION &2175$&76
IMP 1.04
CRITICAL PATH ANALYSIS: PROJECT DESIGN PROJECT DESIGN PROJECT DESIGN
ID # ID #
A AB BC CD DE EF FG GH HI I J J K K L L M M N N O O P P Q Q R R S S T T
Task Description Task Description
Duration Precedent Succeedin Duration Precedent Succeeding Task Task Task Task 2 days B, C,D
Client Meeting to establish goals and vision Client Meeting establish goals and vision 2 days B, C,D Identify LandtoUse and Zoning Requirements 1 day A F Identify Land Use and Zoning Requirements 1 day A F Identify Building Use and Scope 7 days A E Identify Building Use and Scope 7 days A E Catalog Site utilization and conditions 3 days A E,G Catalog Site utilization and conditions 3 days A E,G Identify Deviations from Code Stipulations 1 days C,D G Identify Deviations from Code Stipulations 1 days C,D G ID # Task Description Analyze Demographic and Environmental Data 5 days B G Analyze Demographic and Environmental Data 5 days B G Determine Program 2 Counter days D,E,F H A Zoning Determine Program 2 days D,E,F H Integrated Design Process Discussion 3 days G I, J, K B Site Plan Review Integrated Design Process Discussion 3 days G I, J, K review Determine Materials and Construction Types C Building 6 days H K Determine Materials and Construction Types 6 days H K D Engineer's counter Determine Heating & Cooling Methods 3 days H K Determine Heating & Cooling Methods 3 days K E Licence and Cashier H Counter Code Analysis 2 days I, J L F Land Operations permit Code Analysis 2 days I, J review L Conceptual Drawings 2 days Home Rehabilitation K M, N G URA Pittsburgh Conceptual Drawings 2 days K M,Progra N Preliminary Architecture Drawings days L O H Hope18 VI Application Preliminary Architecture Drawings 18 days L O I Energy Door and Window Specification 4 Policy days Act grant L O Door and Window Specification 4 days L O J Home2Depot Consultant Meeting daysGrant M,N P, Q Consultant Meeting 2 days M,N Construction P, Q K Owner's Permit to Proceed Mechanical System Drawings 18 days O R L Acquire Materias Mechanical System Drawings 18 days O R Refined Drawings 18 days P R M Renegotiate Refined Drawings 18 days contractPaccoring to grants R rec Verification and assesment of proposed systems 2 days P,Q S Verification and assesment of proposed systems 2 days P,Q S Final Construction Documents 18A,days T Critical Path: B, C, D, E, F, R K, L, M Final Construction Documents 18 days R T Final Verification with consultants 3 days S Final Verification with consultants 3 days S 8
Critical Path: A, B, F, G, H, I, K, M, O , P, Q, R, S,0 T Critical Path: A, B, F, G, H, I, K, M, O , P, Q, R, S, T 0
A
3
3
B
8
3
3
3
5
8
8
8 11 2 2
2
2
B B
1
1
3 3
3
3
3 3
3
F F
5
5
3
8 8
8
8
15 15
0 0 0
0
A A 2
2
2 2
2
2
2 2
7
7
C C
7
7
9 9
14
14
9 9 8
8
E E 1
1
10 10 10
10
10 10 10
10
G G 2
2
12
12 12
12
12
12
12
12
H H 3
3
15 15
2
Key Key Early Early Start Start Late Late Start Start
7
7
D 3
D
15
15
3
5 10
10
Milestone Activity Early Milestone Activity Early ID IMPLEMENTATION Finish ID Finish &5,7,&$/ 3$7+ $1$/<6,6 352-(&7 '(6,*1 Normal Activity Normal Activity Late Duration Late Duration Finish (Days) Finish (Days)
IMP 2.00
18
5
6
6
21 21
21
21
21
15 15
2
15
15
I I
18
J J 3
3
18 18 21
21
21 K 21 2
21
Key Early Start
Activity Early ID Finish
Late Start
Duration Late Finish (Days)
Milestone Normal Activity
K
2
ACTION UPTOWN: 2FILL
ARC48_550
PROJECT PROJECT SCOPE W1 W2 SCOPE
10% 35% 65% BENCHMARK 10% 35% 65% BENCHMARK ng W3 W4 W5 W 6 W 7 W 8 W 9 W 10 W 11 W 12 W 13 W 14 W 15 W 16 W 17 W 0-5 1 W2 3 W16-20 4 W21-25 5 W26-30 6 W31-35 7 W36-40 8 W41-45 9 W46-50 10 W 51-55 11 W 12 W 13 W 14 W 15 W 16 W 81-86 17 6-10W11-15 56-60 61-65 66-70 71-75 76-80 0-5 6-10 11-15 16-20 21-25 26-30 31-35 36-40 41-45 46-50 51-55 56-60 61-65 66-70 71-75 76-80 81-86 D
K
2
25
23 23 23
23
23 23
23 L 23 2
L 2
25 25
25
25 M 25 18
M 43 18 43
43
45
43 43
25
25 25 39
25 N 39 4
N 4
29 29 43
43
43
43 O 43 2
O 45 2 45
45
45
45 P 45 18
P
63
63 18 63
63 63
45 45 45
45 Q 45 18
Q 63 18 63
63
63
63 R 63 2
R 65 2 65
65 65
65 65
65 S 65 18
S 83 18 83
83 83
83 83
83 T 83 3
T 86 3 86
63
IMPLEMENTATION &5,7,&$/ 3$7+ $1$/<6,6 352-(&7 '(6,*1
IMP 2.01
86 86
&5,7,&$/ 3$7+ $1$/<6,6 35( &216758&7,21 ID #
Task Description
A B C D E F G H I J K L M
Duration
Precedent Task
Z Zoning Counter 7 days Site Plan Review 5 days Building review 8 days Engineer's counter 5 days Licence and Cashier Counter 4 days Land Operations permit review 10 days URA Pittsburgh Home Rehabilitation Program Grant 20 days Hope VI Application 20 days Energy Policy Act grant 20 days Home Depot Grant 20 days O Owner's Permit to Proceed Construction 2 days A Acquire Materias 20 days Renegotiate contract accoring to grants received 6 day
A B B C, D E F F F F F K G, H, I, J, L
Succeeding W 0 Task
B C, D E E F K M M M M L M
Critical Path: A, B, C, D, E, F, K, L, M
0
A
3
3
B
8
0
3
3
3
5
8
Key Early Start
Activity Early ID Finish
Late Start
Duration Late Finish (Days)
IMP 2.02
Milestone Normal Activity
IMPLEMENTATION &5,7,&$/ 3$7+ $1$/<6,6 35( &216758&7,21
8
C
16
8
8
16
8
D
13
11
5
16
16
E
20
20
16
4
20
20
ACTION UPTOWN: 2FILL
W1 0-5
W2 W3 W4 W5 W6 W7 W 8 W 9 W 10 W 11 W 12 6-10 11-15 16-20 21-25 26-30 31-35 36-40 41-45 46-50 51-55 56-60
ARC48_550
35( &216758&7,21
The Pre- Design phase is expected to last for 58 days. However, every grant has its own application date deadline which may be far in advance, so the duration of that activity might EH H[WHQGHG VLJQLÂż FDQWO\ *UDQWV DUH not guaranteed, and when they are awarded the contract has to be renegotiated to take into account the new funds. Additionally, grant money may only be available 6 months after it was awarded or may work in a reimbursement mechanism. These factors make the grant process uncertain and time consuming. Apart from the grant activities, most of the other steps belong to the critical path. Even though generous time allowances were given to each activLW\ XQIRUVHHQ GLIÂż FXOWLHV DQG REVWD cles might arise that will require more WLPH WR DFFRPSOLVK D VSHFLÂż F WDVN ,I this happens, the rest of the activitiesâ&#x20AC;&#x2122; start dates will be pushed backed as they are conditional in the completion of their predecessor.
F
30
30
K
32
32
L
52
52
M
58
10
30
30
2
32
32
20
52
52
6
58
30
G
50
32
20
52
30
H
50
32
20
52
30
I
50
32
20
52
30
J
32
20
50 52 IMPLEMENTATION &5,7,&$/ 3$7+ $1$/<6,6 35( &216758&7,21
IMP 2.03
CRITICAL PATH ANALYSIS: CONSTRUCTION ID #
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A1 A A2
Task Description
Duration
Precedent Task
Site Move In 2 days Demolition 2 days Excavation 3 days Foundation Pour (includes curing) 4 days Install Rainwater catchment tank 2 days Basement Conrete Wall Construction (includes curing) 4 days Backfill 1 day First Floor SIP Installation 4 days First Floor Wall Construction 3 days Construction Circulation 8 days Second Floor Wood Frame 3 days Second Floor Wall Construction 3 days Third Floor Wood Frame 3 days Third Floor Wall Construction 3 days Slanted Roof SIP Construction 14 days Mechanical/Electrical/Plumbing System Installation 24 days Insulation Installation 3 days Exterior Wall Finishes 6 days Inspection 2 days Install Windows and Doors 5 days Interior Wall Finishes Installation 6 days Install flooring finishes 7 days Inspections 4 days Add soil to terraces and green roofs 1 day Prepare backyard ground 1 day Plant grass on site 1 day Final Inspection Pre-move in 1 day Site Move out 2 days
Succeeding Task
W1 0-5
W2 W3 W4 6-10 11-15 16-20 2
B C D, E E, F G G H I J, K N L M N O Q O R S T U V W A1 Z Z A1 A2
A B C C F E, F G H I I K L M N I N, O R R S S, T U V T T X, Y Z A1
Critical Path: A, B, C, D, F, G, H, I, K, P, L, M, N, O, P, Q, R, S, T, U, V, W, A1, A2
0
A
2
2
2 4
2
B
2
2
4 4
4
C
4
3
7 7
11
E
13
13
2
15
23
P
47
25
24
49
7
D
11
15
G
16
16
H
20
20
I
23
23
K
26
26
L
7
4
11
15
1
16
16
4
20
20
3
23
23
3
26
26
3
23
J
31
24
8
32
11
F
15
11
4
15
Key Early Start Late Start
Activity Early ID Finish Duration Late Finish (Days)
IMP 2.04
Milestone Normal Activity
IMPLEMENTATION &5,7,&$/ 3$7+ $1$/<6,6 &216758&7,21
52 52
ACTION UPTOWN: 2FILL
ARC48_550
&216758&7,21
W5 W6 W7 W 8 W 9 W 10 W 11 W 12 W 13 W 14 W 15 W 16 W 17 W 18 W 19 21-25 26-30 31-35 36-40 41-45 46-50 51-55 56-60 56-60 56-60 61-65 66-70 71-75 76-80 81-85
The construction phase is composed of many small steps that are sequential to one another. Many of the activities can only happen once their predecessor is completed, which limits the number of task overlaps and rolled up milestones. 7KLV SUREOHPV LV HQKDQFHG E\ WKH QDU row site conditions and that only a few workers and machinery can access the VLWH DW RQFH 1HSKURVFOHURVHV WKH FRQ struction can be completed in less than three months because standardized construction parts were chosen and easy to install materials were taken into DFFRXQW LQ WKH GHVLJQ DQG FRVWLQJ SUR cess. The most important tasks are the VXFFHVVIXO SRXULQJ RI WKH VODE DQG EDVH ment, without this step the construction cannot continue. Another important task is the completions of all mechanical, HOHFWULFDO DQG SOXPELQJ V\VWHPV EH cause these are the tasks that require the most time to resolve and consume WKH PRVW PDQ KRXUV DQG PRQH\ $U ranging for the correct inspections will UHTXLUHG WLPH VR LW LV FULWLFDO WKLV DFWLY LW\ Âż QLVKHG RQ VFKHGXOH )LQDOO\ WKH VLWH move is very important in order to meet WKH VFKHGXOH SUHVHQWHG WR WKH FOLHQW $F 29
29
M
32
3
N
35
35
O
49
49
Q
52
29
29
3
32
32
3
35
35
14
49
49
3
52
R
58
6
58
58
S
60
60
T
65
58
2
60
60
5
65
tion Uptown, and to allow them to bring in the new residents in.
65
U
71
71
V
78
78
W
82
82
A1
83
83
A2
84
65
6
71
71
7
78
78
4
82
82
1
83
83
1
84
65
X
66
80
1
81
65
Y
66
80
1
81
66
Z
67
81
1
82
IMPLEMENTATION &5,7,&$/ 3$7+ $1$/<6,6 &216758&7,21
IMP 2.05
RENT STRUCTURE 5HQWLQJ WKH Âż UVW VWRUH\ RQH EHGURRP XQLW ZLOO SURYLGH DGGLWLRQDO LQFRPH IRU WKH UHVLGHQWV 7KH UHQWDO LQFRPH ZLOO KHOS VXEVLGL]H WKH FRQVWUXF tion cost and will allow the residents to afford a better design and home. The rental income will help the residents pay for their mortgage faster, increase their home equity quicker, and pay less money as interest from the mortgage loan. Additionally, the rental unit will bring in more residents into Uptown, effectively increasing its population, density, and tax base. These are measure that will evitalize the area and spur growth.
Rental Cost for different areas:
1 - Bedroom Unit: 897 sq.ft. 60 cents / sq. ft. / month 897 sq. ft x 60 cents / sq. ft. = $538/ month Common Areas: 440 sq. ft. ) Includes basement and entry stairs) 25 cents / sq. ft. / month 440 sq. ft. x 25 cents / sq. ft. = $110/ month Garden: 360 sq. ft. 20 cents / sq. ft. / month 360 sq. ft. x 20 cents / sq. ft. = $72/ month
7RWDO PRQWK RENT = PRQWK
:H H[SHFW WKDW UHQW ZLOO EH LQFUHDVHG E\ HYHU\ \HDU WR FRPSHQVDWH IRU LQĂ&#x20AC; DWLRQ
0RQWK January February March April May June July August September October November December
Accumulated 0RQWKO\ 5HQW Income 720 720 720 720 720 720 720 720 720 720 720 720
yearly Income 8640
720 1,440 2,160 2,880 3,660 4,320 5,040 5,76 6,480 7,200 7,920 8,640
year # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Income 8640 9,072 9,525 10,002 10,502 11,027 11,578 12,157 12,765 13,403 14,074 14,777 15,516 16,292 17,107 Total
Accumulated Income 8,640 17712 27237 37,239 47,741 58,768 70,346 82,503 95,268 108,671 122,745 137,522 153,038 169,330 186,437 186,437
7KH 5HQWDO ,QFRPH RQ WKH Âż UVW \HDU LV ZKLFK LV HTXLYDOHQW WR RI WKH WRWDO FRQVWUXFWLRQ FRVW
By year 15, the accumulated income is $186, 436 account for an accrued 5% increase in rent. This is equivalent to 51% of the total construction cost. :H DUH SULFLQJ WKH UHQWDO XQLW EHORZ PDUNHW UDWH LQ WKH JUHDWHU 3LWWVEXUJK DUHD E\ DERXW EHFDXVH ZH ZDQW WR PDNH LW DSSHDOLQJ IRU \RXQJ SURIHVVLRQ als to move into the Uptown Neighborhood. Having a lower price point is a great incentive for younger people, and will help compensate the fact that the rest of the area is not in the best condition.
IMP 3.00
IMPLEMENTATION 5(17 6758&785(
COSTS DATA METHODOLOGY
ACTION UPTOWN: 2FILL
ARC48_550
/LPLWDWLRQV 8VLQJ 560HDQV
We are using RSMeans Assemblies Cost Data 2011 to derive most of the cost estimates for our project. The main limitations and disadvantages when using this as our main reference guide are the following: All costs in the book are U.S. national averages and may vary according to the regional economy. 7KH ERRN LV DLPHG SULPDULO\ DW ODUJH FRPPHUFLDO LQGXVWULDO DQG PXOWL IDPLO\ KRXVLQJ SURMHFWV Costs can also vary according to the quality of the materials, the amount of overtime the labor force works, productivity rates of the labor force which is affected by amount of experience, weather conditions, and type and quality of equipment used, and the size and scope of the project.
3URMHFW 6L]H ,PSOLFDWLRQV RQ &RVW 7KH VL]H DQG VFRSH RI WKH SURMHFW ZLOO DIIHFW LWV FRVW VLJQLÂż FDQWO\ (FRQRPLHV RI VFDOH UHGXFH WKH FRVW IRU ODUJH SURMHFWV ZKLOH WKH LQYHUVH KDSSHQV for small ones. Unit costs for smaller projects tend to be higher than the national average because it is a greater effort for a contractor to construct something of a smaller scale since it still requires lots of planning and organization. The higher costs per element in smaller projects are meant to compensate the contractorâ&#x20AC;&#x2122;s potential opportunity cost lost. Because our project is small scale, we are going to use the RSMeans Cost Data as DQ LQLWLDO UHIHUHQFH SRLQW EXW ZLOO WKHQ SDVV LW WKURXJK D UHDO ZRUOG FRVW Âż OWHU WR GHWHUPLQH D PRUH DFFXUDWH SULFH IRU RXU SURMHFW
/RFDWLRQ 0XOWLSOLHU Location Factor Multiplier for Pittsburgh is 100.9 which is a negligible difference from the national standard. Hence, we are not adjusting the estimated costs derived from RSMeans Assemblies Cost Data 2011 based on the location factor.
&RQWLQJHQFLHV Contingencies are allowances that are included at the conceptual and design stages of a project to allow for design decisions to be made as the project progresses. Design Contingencies: 3UH 'HVLJQ Schematic Design:10% Design Development: 5% Construction Documents: 5% 3UH %LG (VWLPDWHV Construction Contingency: 5% for any unforseen conplications
6TXDUH )RRW &RVWV Square foot costs allow one to make rough estimates for the overall cost of a project or its components during the initial stages of a project. This HVWLPDWH LQFOXGH D FRQWUDFWRUÂśV RYHUKHDG DQG SURÂż W EXW GR QRW LQFOXGH DUFKLWHFWXUDO IHHV RU ODQG FRVWV :H DUH XVLQJ WKH PHGLDQ GDWD FRVW JLYHQ in RSMeans 2011.
Element Site Work Equipment Plumbing HVAC Electric Total M + E Total Cost
Unit Cost ($) S.F. 13.95 S.F. 3.38 S.F. 7.35 S.F. 5.35 S.F. 6.85 S.F. 28 S.F. 106
% of Total 11.75 3.03 9.05 6.05 6.55 17.55 100
The Gross Floor Area (GFA) for our building is 3,127 sq. ft. 3,127 sq.ft. x $106/ sq.ft. = Architectural fees 15% $331,462 x 1.10 = 727$/ &267 Total M + P + E Cost $28/ S. F. $28/ S. F. x 3,127 S. F. of livable area = $88,000
IMPLEMENTATION COST DATA METHODOLOGY
IMP 3.01
HARD COST BREAKDOWN Hard Costs &DWHJRU\
Substructure Superstructure Interiors Services (TXLSPHQW DQG )XUQLVKLQJ Rental of Community Garden
Total cost of Element ($)
&RVW RI (OHPHQW IW
39,000.00 108,758.98 82,160.95 74,662 5,411 6,000
Total Hard Costs
Meeting the goals for affordable housing
SOFT COSTS BREAKDOWN Type
Sales Tax General's contractor overhead and profit Design Fees Management Legal Fees Insurance Construction Contingency Impact Fees
Total Soft costs
10.33 22.81 18.14 19.78 1.43 1.59
8QLW 5.07 8 15 3 3 2.5 4 2
Soft costs were calculated based on the percentage of Total Hard Costs.
Amount ($)
18,011.62 25,279.46 47,398.99 9,479.80 9,479.80 7,899.83 11,059.77 4,739.90
CONSULTANT FEES Type
8QLW
Structural Fees Civil Fees Mechanical and Plumbing Landscape Fee Miscellaneous Job Specific
Amount ($)
11.00 5213.89 1.00 473.99 24.40 11565.35 1.00 473.99 2.10 995.38 Consultant fees were calculated on a percentage based on the design fee of soft costs. Consultant fees are deducted from the total design fees. The percentages were based on AIA manual recommendations for standard consultant work.
OVERALL COSTS Total Hard Costs Total Soft Costs 7RWDO 3URMHFW &RVW
IMP 3.02
$ $ $
IMPLEMENTATION 29(5$// &267 %5($.'2:1
&RVW RI (OHPHWQ IW 4.77 6.70 12.56 2.51 2.51 2.09 2.93 1.26
,ĂƌĚ ŽƐƚ ƌĞĂŬĚŽǁŶ Ϯй Ϯй
ACTION UPTOWN: 2FILL
,ĂƌĚ ŽƐƚ ƌĞĂŬĚŽǁŶ Substructure
Ϯй Ϯй
ϭϰй
Substructure
Superstructure Soft
ϭϰй
Superstructure
Ϯϳй
Ϯϳй
Costs Sales Tax
Interiors
Interiors
ϯϭй
ϯϭй
6%
8% 7% 6%
4%
Design Fees
Rental of Community Garden
Soft Costs 4%
General's contractor overhead and profit
Equipmentand and Furnishing Equipment Furnishing
Soft Costs 7%
8%
4%Services Services 13%
8%
6%
Ϯϰй
Ϯϰй
ARC48_550
Rental of Community Garden Management
Sales Tax
19%
General's contractor Sales Taxoverhead and profit
13%
7%
Legal Fees
Design Fees
General's contractor overhead
13% 19%
and profit Management Legal Fees Design
7%
Fees
Insurance Construction Contingency
36%
Insurance
Management
7%
19%
36%
Impact Legal Fees
7% ϯй ϯй
Impact Fees
Construction Contingency
Fees
Insurance ϱй ϱй
^ƚƌƵĐƚƵƌĂů &ĞĞƐ ^ƚƌƵĐƚƵƌĂů &ĞĞƐ
Construction Contingency
Ϯϴй Ϯϴй
36%
ϯϵй ϯϵй
ŝǀŝů &ĞĞƐ ŝǀŝů &ĞĞƐ
Impact Fees
Ϯй Ϯй ϲϮй ϲϮй
DĞĐŚĂŶŝĐĂů ĂŶĚ WůƵŵďŝŶŐ DĞĐŚĂŶŝĐĂů ĂŶĚ WůƵŵďŝŶŐ
ϲϭй ϲϭй
ConsultantFees Fees Consultant Remaining Remaining DesignFee Fee Design
>ĂŶĚƐĐĂƉĞ &ĞĞ >ĂŶĚƐĐĂƉĞ &ĞĞ DŝƐĐĞůůĂŶĞŽƵƐ :Žď ^ƉĞĐŝĨŝĐ DŝƐĐĞůůĂŶĞŽƵƐ :Žď ^ƉĞĐŝĨŝĐ
Ϯϵй
dŽƚĂů ,ĂƌĚ ŽƐƚƐ Ϯϵй
dŽƚĂů ^ŽĨƚ ŽƐƚƐ dŽƚĂů ,ĂƌĚ ŽƐƚƐ
ϳϭй
dŽƚĂů ^ŽĨƚ ŽƐƚƐ
ϳϭй
IMPLEMENTATION '2&80(17$7,21 IMPLEMENTATION OVERALL COST BREAKDOWN
IMP 3.03
HARD COST ANALYSIS Substructure CSI Code
A10
Substructure
1.01
A10301204480
Slab on grade
ubstructure1.02
A20101102340
Basement Excavation
1.03
A20201105000
Basement Walls
100
1.04
3114132331400
Top Soil Stripping
3781
CY
1
Element
4XDQWLW\
8QLW
ID #
650
Substructure 650
ϭϯй
S.F
5.98
S.F
14.6
L.F.
126
Basement Excavation Basement Walls
ϯϭй
ϯϲй
н&
2.07
Subtotal
Basement Excavation Basement Walls
(TXLSPHQW DQG )XUQLVKLQJV ID #
CSI Code
Element
4XDQWLW\
8QLW
Element Material 8QLW UDWH Cost ($)
E
(TXLSPHQW DQG )XUQLVKLQJV
5.01 5.02 5.03 5.04
E20202100720 E2020220230 E20202200910 113113232050
Furnishings Furniture and Accessories Furniture and Accessories Refrifinartion Equipment
2 2 2 1
Unit Unit Unit Unit
821 327 111 943
715 271 111 943
5.05
113113130020
Cooking Range
1
Unit
506
506
5.06
113123136750
Washing Machine
1
Unit
768
768
5.07
113123236770
Dryer
1
Unit
676
676
н&
Subtotal 30%
Furnishings
13%
Furniture and Accessories 30%
Furniture and Accessories
Refrifinartion Equipment
14%
Washing Machine
Furniture and Accessories
Refrifinartion Equipment Cooking Range
9%
Washing Machine
Dryer
12% 18%
IMP 3.04
Furnishings Furniture and Accessories
Cooking Range
12%
29.5
Slab on grade
Slab on grade
5
3.01
ϭϯй
ϮϬй
ϯϭй
Element 8QLW UDWH Material RSMeans Cost ($)
IMPLEMENTATION HARD COST ANALYSIS
4%
Dryer
/DERU Cost ($)
Total cost of Element Cost of element ($) Based on SHU IW RI JURVV RSMeans Total Actual Cost ($) IORRU DUHD IW
Specifications
3,887.00
5,000.00
1.32
14.6
9,490.00
12,000.00
3.18
6" thick, non industrial reinforces 8' deep, sand, gravel, or common earth, on site storage
96.5
12,600.00
14,000.00
3.71
8' high wall, 6" thick
2.07
7,826.67
8,000.00
2.12
Loam or topsoil removal
2.97
&RQWULEXWLQJ )DFWRUV
6LWH FRQGLWLRQV WKH VLWH LV ORQJ QDUURZ DQG Ă&#x20AC;DQNHG RQ WZR VLGHV E\ H[LVWLQJ EXLOGLQJV *HWWLQJ D EDFNKRH to excavate the basement and foundations will be challenging and require more time. Soil disposal: The trucks that will haul away the excavation soil will have to also maneuver in tight spaces DQG EH DORQJ D URDG WKDW KDV PRGHUDWH DPRXQW RI WUDIÂżF Water management: the City of Pittsburgh requires to separate storm-water and sewage pipes incurring and additional cost
/DERU Cost ($) 106 106
Total cost of Element Cost of element ($) Based on SHU IW RI JURVV RSMeans Total Actual Cost ($) IORRU DUHD IW
Specifications
1,642 654 222 943
1,642 654 222 943
0.43 0.17 0.06 0.25
Upholster seats, foursome, single economy Dressing unit, built in, economy Wardrobes and coatracks Deep Freeze, 15 to 23 CF
506
506
0.13
Cooking range, 30" free standing, 1 oven
768
768
0.20
Energy Star qualified, from loading washer Energy Starqualified, electric, front loading dryer
676
676
0.18
&RQWULEXWLQJ )DFWRUV One of Action Uptownâ&#x20AC;&#x2122;s main goals is to reduce the utility bills for the future residents of their properties. Selecting
(QHUJ\ 6WDU TXDOLÂżHG DSSOLDQFH ZLOO KHOS UHGXFH WKH XWLOLW\ ELOO FRVWV LQ WKH ORQJ WHUP (YHQ WKRXJK WKHVH DSSOLDQFHV DUH slightly more expensive than conventional ones, the medium and long term payout offsets the initial extra cost.
IMPLEMENTATION HARD COST ANALYSIS
IMP 3.05
HARD COST ANALYSIS Superstructure ID # 2 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08
2.09 2.1 2.11 2.12 2.13 2.17 2.18 2.19
CSI Code
Element
4XDQWLW\
B10 Superstructure B10102612600 Wood Stud B10102613400 Wood Joist B10102613800 Wood Joist B1011002161025 Header/ Footer C10101285540 Base plate and Top plate for SIP B20101500 Brick Veneer/ Wood Stud backup B201015004000 Wood Exterior Siding B20101483150 Vinyl Siding B20201023100 B20201024550 61210100110 61210100210 61210100110 B30101401095 15423700091 329313100012
Wood Windows Wood Windows SIP Wall SIP Roof SIP Floor Asphalt shingles Scaffolding Landscaping
Element Material 8QLW UDWH Cost ($)
464 265 1,703 234 778 621 649 2,455
L.F. L.F. L.F. L.F. L.F. S.F. S.F. S.F.
2.62 3.16 3.34 2.5 2.5 23.2 9.36 7.66
1.27 1.62 1.78
16 1 4,482 1,088 1,063 1,196 6 24
Unit Unit S.F. S.F. S.F. S.F. C.S.F. S.F.
486 965 4.92 6.37 5.54 1.91 115 121
256 630 4.13 5.27 4.63 0.88 68.5 86
7.45 3.76 2.74
Subtotal
rstructure
8QLW
Ϯй
ϭϱй
ϲй
Superstructure Wood Stud Wood Joist Wood Joist Header/ Footer Base plate and Top plate for SIP Brick Veneer/ Wood Stud backup Wood Exterior Siding Vinyl Siding Wood Windows Wood Windows SIP Wall SIP Roof SIP Floor Asphalt shingles Scaffolding Landscaping
IMP 3.06
IMPLEMENTATION HARD COST ANALYSIS
Ϯй ϭй
ϭй ϭй
ϯй
ϲй
ϭй
ϲй
Ϯй
ϳй ϭϱй
ϲй
ϮϮй
ϭϵй ϭй
ϴй
Wood Stud Wood Joist Wood Joist Header/ Footer Base plate and Top plate for SIP Brick Veneer/ Wood Stud backup Wood Exterior Siding Vinyl Siding Wood Windows Wood Windows SIP Wall SIP Roof SIP Floor Asphalt shingles Scaffolding Landscaping
ACTION UPTOWN: 2FILL
/DERU Cost ($)
Total cost of Element Cost of element ($) Based on SHU IW RI JURVV RSMeans Total Actual Cost ($) IORRU DUHD IW
1.35 1.54 1.56
15.75 5.6 4.92
1,215.68 837.40 5,688.02 585.00 1,945.00 14,407.20 6,074.64 18,805.30
1,337.25 921.14 6,256.82 643.50 1,945.00 15,847.92 6,682.10 20,685.83
0.35 1.00 0.31 0.17 0.52 3.04 1.28 3.97
230 335 0.49 0.9 -2.5 1.03 68.5 47
7,776.00 965.00 22,051.44 6,930.56 5,889.02 2,284.36 690.00 2,904.00
8,553.60 1,061.50 24,256.58 7,623.62 6,477.92 2,512.80 759.00 3,194.40
1.64 0.20 6.43 2.02 1.72 0.48 0.20 0.85
ARC48_550
Specifications "2 x 4", 24" OC "2 x 6", 48" O.C. "2 x 10", 24" O.C. "2 x 4" 2" x 6" 2x6 wood, 24" stud spacing 1" x 12" rough sawn cedar Plain vynil siding 8" Wood Double hung insulated glass, 2' 8" x 4'6" Picture window insulated glass 6.5" thickness 8.25" thickness 6.5" thickness Strip shingles, 4" slope, inorganic Scaffolding, steel tubular, regular Ground cover, plans, Vinca minor
&RQWULEXWLQJ )DFWRUV Roof Type: the roof of our building is complex structurally because of its slope and because of the skylights in bedded inside it. M+P+E integration is straightforward and we kept as few water-walls and ductwork as possible to reduce the associated costs. Insulation: SIP panels reduce insulation, construction, and installation costs
&ODGGLQJ ZH XVHG EULFN DQG ZRRG YHQHHUV WKURXJK RXU EXLOGLQJ EHFDXVH WKH\ ÂżW ZLWKLQ WKH XUEDQ FRQWH[W DQG the materials used by other materials along the street. These materials are not high performance but are cheap cladding options as well. Opening: we used standardized window sizes to reduce their material cost and potential additional fabrication cost.
Because of these reasons
we LQFUHDVHG WKH HOHPHQW FRVW ZH JRW IURP 560HDQV E\ to account for the
contributing cost factors. The 10% increase in cost is also based that our house is a small project hence, contractors will charge more to do the same work if it were for a large scale project.
IMPLEMENTATION HARD COST ANALYSIS
IMP 3.07
HARD COST ANALYSIS Interiors
C1010
Interiors
3.01 3.02
C10101241500 C10201201600
Drywall Partitions Wood Door/ Wood Frame
2,918 14
S.F. Unit
4.99 395
1.75 170
3.03
C10201141000
Metal Door/ Metal Frame
2
Unit
1,055
690
3.04
C10201141160
Metal Door/ Metal Frame
1
Unit
1,805
1,225
3.05
C20101100550
Stair
6
Cost per flight
3,800
142.08
3.06 3.07 3.08
C30102300080 C30204100500 C30204101600
Paint and Covering Wood Composite Flooring Tile and covering Bathrooms
1900 2263 1,800
S.F. S.F. S.F.
1.08 5.51 2.84
0.17 3.01 1.9
3.09
C10101440345
Batten
43
Unit
25
3.1 3.11
B20201023100 B20201024550
Wood Window Picture Frame window
13 1
Unit Unit
486.00 860
256 560
Subtotal
/ŶƚĞƌŝŽƌƐ
Drywall P
ϭй
ƌŝŽƌƐ
й
4XDQWLW\
Element Material 8QLW UDWH Cost ($)
CSI Code
3
Element
8QLW
ID #
Drywall Partitions
ϭй
Wood Door/ Wood Frame
Wood Do
ϴй
ϳй
Metal Door/ Metal Frame Metal Door/ Metal Frame
Wood Composite Flooring
ϭϳй
ϯй
ϯй
Picture Frame window
IMP 3.08
IMPLEMENTATION HARD COST ANALYSIS
Wood Co Tile and
Ϯй
й Wood Window
Paint and
ϳй
Tile and covering Bathrooms Batten
Metal Do Stair
Stair Paint and Covering
Metal Do
ϮϬй
ϯϭй
Batten
Wood W
Picture F
ACTION UPTOWN: 2FILL
/DERU Cost ($)
Total cost of Element Cost of element ($) Based on SHU IW RI JURVV RSMeans Total Actual Cost ($) IORRU DUHD IW
3.24 225
14,560.82 5,530.00
16,016.90 6,083.00
3.07 1.18
365
2,110.00
2,321.00
0.46
580
1,805.00
1,985.50
0.38
504.96
22,800.00
25,080.00
6.83
0.91 2.5 0.9
2,052.00 12,469.13 5,112.00
2,257.00 13,716.04 5,623.20
0.43 2.63 0.69
1,075.00
1,182.50
0.38
6,318.00 860.00
6949.80 946.00
1.84 0.25
230 300
ARC48_550
Specifications
1/4" SD gypsum, nothing in opposite face Hallow core/ flush, Pine Flush Hallowm steel door, float glass. 3'-0" x 7'-0" Flush Hallowm steel door, float glass. 6'-0" x 7'-0" C.I.P. Stairs with landing, concrete in place, free standing Painting Interior on plaster or drywall. Primer, 1st and 2nd coat. Polyester with colored quart Vynil tile, maximum 2" x 2" x 9' Wood Window double hung insulated glass 2" Picture window insulated glass
&RQWULEXWLQJ )DFWRUV Partition density was kept to a minimum to reduce to construction costs associated and to create a feeling of large and open spaces for the residents. Many of the structural and construction materials are exposed reducing the need for additional decor and effectively reducing the interiors construction cost. Floor to ceiling heights were designed in accordance to standard material dimensions to eliminate the need for customization and therefore increase the cost. The staircase is the most expensive component in the interior construction. We used a simple free standing stair to minimize the cost of this element, partially in expense of its aesthetics. We used the same tiles for the bathrooms and kitchen to minimize waste and to be able to reuse smaller pieces in different locations. Due to these reasons we LQFUHDVHG WKH HOHPHQW FRVW ZH JRW IURP 560HDQV E\ to account for the contributing cost factors. The 10% increase in cost is also based that our house is a small project hence, contractors will charge more to do the same work if it were for a large scale project.
IMPLEMENTATION HARD COST ANALYSIS
IMP 3.09
HARD COST ANALYSIS Services Element Material 8QLW UDWH Cost ($)
CSI Code
Element
4.01
D20103101560
Lavatory Systems
1
Unit
1,210
530
4.02
D20104101720
Kitchen Sink Systems
2
Unit
1,430
685
4.03
D20109201180
Two Fixture Bathroom
3
Unit
3,675
1,800
4.04
D20202501780
Domestic Water Distribution
1
Unit
741
409.5
4.05 4.06
D20402101880 D30201020112
Rain Water Drainage Heat generating System
1 1
Unit Unit
926 6,325
286 4,702
4.07 4.08 4.09 4.1 4.11
D50101200200 D50102400200 D50201100190 D50201300200 D50202140380
Electric Service/ distribution Switchgear Lighting and branch wiring Lighting and branch wiring Lighting and branch wiring
2 1 13 9 9
Unit Unit S.F. S.F. S.F.
1,877 8,250 1.71 1.17 32.65
960 4500.00 0.38 0.25 13.38
4.12 4.13
D50905101000 230713103000
Electric Baseboard Radiation Duct thermal Insulation
3,775 S.F
S.F. 3775.00
3.66 2.45
1.22 1.51
4.14 4.15
953105040 23050101000
Thermostat HVAC Ductwork
5 3775
Unit L.F.
99.00 1.53 Subtotal
72.00 0.91
4
D
4XDQWLW\
8QLW
ID #
Services
Services
ces
Lavatory Systems Kitchen Sink Systems Two Fixture Bathroom
Heat generating System
ϭй
Two Fixture Bath
Domestic Water
ϰй
ϵй
Rain Water Drain Heat generating
ϭϳй
ϭϰй
Electric Service/
ϭй
Electric Service/ distribution
ϭй ϭй
Switchgear
ϭй
Lighting and branch wiring Lighting and branch wiring Lighting and branch wiring
ϭϬй
Ϯϭй
Electric Baseboard Radiation
ϳй
Duct thermal Insulation Thermostat
Ϭй
HVAC Ductwork
IMP 3.10
Ϭй IMPLEMENTATION HARD COST ANALYSIS
Kitchen Sink Sys
Ϯй
Domestic Water Distribution Rain Water Drainage
Lavatory System
ϭϯй Ϭй
Switchgear
Lighting and bran
Lighting and bran
Lighting and bran
Electric Baseboa
Duct thermal Insu Thermostat
HVAC Ductwork
ACTION UPTOWN: 2FILL
/DERU Cost ($)
Total cost of Element Cost of element ($) Based on SHU IW RI JURVV RSMeans Total Actual Cost ($) IORRU DUHD IW
680
1,210
1,392
0.37
745
2,860
3,289
0.87
1,875
11,025
12,679
3.36
331.5
741
852.15
0.23
640 1,663
926 6,325
1064.9 7,274
0.28 1.93
920 3,750 1.33 0.92 18.85
3,754 8,250 22 10.53 293.85
5,000 9,488 26 12.1095 337.93
1.32 2.51 0.01 0.00 0.09
2.44 2.33
13816.5 9248.75
15,889 10173.63
4.21 2.70
27.00 0.62
495.00 5775.75
544.50 6642.11
0.14 1.76
ARC48_550
Specifications Lavatory, w/ trim vanity top. 19" x 16" oval Kitchen sink w/ trim, countertop, single bowl, 30" x 21" Bathroom, lavatory, water close, 2 wall plumbings stand alone Gas fired water heater, 100 degrees F rise. Copper tubbing, type L, solder joint Roof drain, DWV PVC, 2" diam. Piping 10' high Boiler, electric Breakers, metering, 20' conduit and wire 3 phase. 4 wire, 60 A Switchgear inst., including Duplex receptacle, 2.5 per 1000 SF Light switch controllers Incandesecnt fixture recess mounted Electric baseboard radiation, low density, 9 kW FSK Vapor barrier wrap, 1" thick Energy Star qualified, 1 set back, electric timed Ductwork, 4" high, 8" wide
&RQWULEXWLQJ )DFWRUV 6HUYLFHV VXFK DV SOXPELQJ DQG +9$& UHTXLUH VLJQLÂżFDQW DPRXQW RI PDQXDO ODERU ZKLFK LV WKH PRVW H[SHQVLYH FRPSHQHQW LQ D FRQVWUXFWLRQ 6LP plifying the service requirements will help Action Housing reduce these hard costs. Having a highly insulated house, tighly sealed, and access to natural ventilation will minimize the HVAC requirements to keep the occupants comfortable. The house is sesigned to align water walls, and ventilation shafts ro reduce the installation costs and the amount of materials needed. Because of these reasons we LQFUHDVHG WKH HOHPHQW FRVW ZH JRW IURP 560HDQV E\ to account for the contributing cost factors. The 15% increase in cost is also based that our house is a small project hence, contractors will charge more to do the same work if it were for a large scale project. The service markup is 5% higher than in the other categories because it is extremely time consuming and there can be many unforeseen SUREOHPV UHODWHG WR WKH ZRUN EDWKURRPV DUH QRUPDOO\ WKH URRPV WKDW UHTXLUH WKH PRVW UH YLVLWV DQG UH ZRUNV PDNLQJ WKHP PRUH H[SHQVLYH
IMPLEMENTATION HARD COST ANALYSIS
IMP 3.11
HOMEOWNER MONTHLY BUDGETING Savings constitute 30% of the homeownerâ&#x20AC;&#x2122;s income, intended to EH KHOG IRU ORQJ WHUP VDYLQJV DQG emergencies.
$1,498 misc. expenses
savings
$2,156
$2,060
Renters provide excess savings $720 RI LQFRPH IRU WKH Homeowners ZKR DW
standard expenses
expenses PHGLDQ LQFRPH SHU PRQWK per adult
IRU D WRWDO KRXVHKROG income of Miscellaneous Expenses Miscellaneous expenses can include monthly credit card debt payments, health insurance, and college loan payments. If the homeownerâ&#x20AC;&#x2122;s have children, those expenses would also come out of miscellaneous.
dining out entertainment
IMP 4.00 necessities
IMPLEMENTATION +20(2:1(5 %8'*(7
home transportation
mortgage
homeowners insurance mortgage insurance property taxes
ACTION UPTOWN: 2FILL
ARC48_550
Standard Expenses 6WDQGDUG H[SHQVHV ZHUH EDVHG RQ D WZR SHUVRQ IDPLO\ 'XH WR WKH SULPH location along bus routes, transportation consists of 2 adult monthly bus passes for Port Authority. It was assumed that they do not own or operate a vehicle. Necessities include toiletries, household items, and clothing per month. Entertainment covers movies, short trips, etc. Utilities are based on moderate heating and cooling usage during summer and winter months.
entertainment $300 $150 necessities
7KH PRUWJDJH ZLOO EH SHU PRQWK EDVHG RQ D year loan of $121,500. The homeowners put a down SD\PHQW RI RI WKH KRPHÂśV sale price.
dining out $120
$991
$555
mortgage
home
homeowners insurance mortgage insurance
transportation $195
property taxes $400
utilities
groceries
This analysis is based upon an annual 80% median income which in Pittsburgh, PA is $29,969. Monthly income per homeowner is $2,497. As the homeowners will likely be a couple, with or without children, their combined monthly income from their careers is $4,995.
Savings 6DYLQJV DUH LQWHQGHG IRU VKRUW DQG ORQJ WHUP 3ODQQLQJ WR SXW PRQH\ DZD\ for unforseen expenses, such as home maintenance, family emergencies, or healthcare, is important in maintaining a residence. At the discretion of WKH KRPHRZQHUV VDYLQJV FRXOG DOVR EH EXGJHWHG WR LQFOXGH WULSV DQG QRQ necessities.
2FILL: ACTION UPTOWN PROPOSAL
UDBS/IOP 2012