Architecture + Planning 820 16th Street, Suite 500 Denver, CO 80202 ktgy.com 303.825.6400 FIRE HYDRANT
FIRE HYDRANT
KTGY Project No:
37TH PLACE PROPOSED SIGNAGE 13
7 _____ A1.20 TYP.
GAS METER
10'-3"
CORNICE OVERHANG
160880
PROJECT CONTACT:
CYNTHIA FISHMAN
EMAIL:
cfishman@ktgy.com
PRINCIPAL: PROJECT DESIGNER:
TERRY WILLIS CAITLIN BLYTHE
9 9
PROPERTY LINE
Developer
PROJECT LIMITS
STORAGE 108
TYP
WATER ENTRY
26
106
LOADING BAY / TRASH
CONCRETE TRANSFORMER PAD BY XCEL
LEASE SPACE 12
104
110
101
MAIN ELECTRICAL RM 112
ELEVATOR LOBBY 103
EAST LOBBY
VESTIBULE
113
114
DIGITAL LOUNGE 143
WEST ENTRY
14'-0"
16'-0"
9
PROPERTY LINE
14'-0"
6 _____ A1.20
8
27
EAST ENTRY 3 _____ A1.20
8
8
2
FUTURE CONSTRUCTION N.I.C.
BIKE STORAGE
WEST LOBBY
BREAKOUT SPACE 142 BREAKOUT SPACE
144
PROPERTY LINE
116
EXTERIOR 4
17
141
28
28
6
5
EXTENT OF WORK
58'-0"
14
1
EMERGENCY GENERATOR PAD RE: STRUCTURAL FOR DETAILS AND DIMENSIONS
23'-0"
10'-0
"
CONCIERGE 145
10 _____ A1.20
EMERGENCY GENERATOR
9
MATCHLINE
145
7351 E. 29TH AVE. DENVER, CO 80238 303.382.5950
28
EXTERIOR LIGHTING, RE:ELECTRICAL
CONFERENCE SPACE
LOUNGE 140
8
PRE-FUNCTION 139
242'-0 5/8"
18'-0"
117
2
CONFERENCE SPACE 118
CAFE / LOUNGE RE: 1 / A2.10
BOH
18'-0"
5
138
RE: 1 / A2.10 3
137
3
MATCHLINE RE: 1 / A2.11
D
MATCHLINE RE: 1 / A2.11
6
3
28
28
WOMENS RESTROOM 8
19 44'-7 1/2"
EXIT ENCLOSURE B 18'-0"
131
24'-0" 20
79'-0" 28
17
6'-0"
100'-6" 28
6
RAL P
PLAZA FOUNTAIN ROOM 133
132
C
C
C 8
SOUTH CANOPY
C
PROPERTY LINE
21'-0"
FIRE HYDRANT
C
1'-6"
RE: 1 / A2.12
MATCHLINE
26
C
CEN T
LEASE SPACE
18'-0"
CORNICE OVERHANG
18'-0"
129
SOFFIT OVERHANG EXTENT OF WORK
ARK B
UP
22
CORNICE OVERHANG
MENS LOCKER ROOM
102
78'-7"
SOFFIT OVERHANG
127
STAIR 2
79'-3"
23'-0"
107'-9 1/2" BUILD-TO LENGTH
MENS RESTROOM
18'-0"
123
UINTA STREET
28
OUL EVA R
15
28
EV
121
9'-4"
17
59'-0"
PLAZA N.I.C.
59'-0"
25
WOMENS LOCKER ROOM
23'-0"
EV
2
EXTENT OF WORK
No Date
23 N.I.C. - FOR REFERENCE ONLY
PROPERTY LINE
3700 N. UINTA STREET DENVER, CO
PROJECT LIMITS
10
7 _____ A1.20 TYP.
SERVICE
UP STAIR 1
FOREST CITY
FUTURE CONSTRUCTION N.I.C.
9
109
PROPERTY LINE
CENTRAL PARK STATION ONE
105
105A
7'-0"
10'-0"
IT/MDF
11
18'-0"
LV EQUIP
LOADING BAY / TRASH 1 _____ 17 A1.20
RE: 1 / A2.12
63'-5" BUILD-TO LENGTH
EXTENT OF WORK
Description
07/14/17 DESIGN DEVELOPMENT 12/01/17 GMP/PERMIT
SOUTH ENTRY
EXTENT OF WORK
NOTE: REFER TO SHEET A2.12 FOR ADDTIONAL PARKING/SITE INFORMATION
APARTMENTS N.I.C.
It is the client's responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifivations of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or client's subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed.
NORTH
ARCHITECTURAL SITE PLAN KEYNOTES - SITE PLAN #
PLOT DATE: 2/1/2018 2:07:57 PM
1 2 3 4
DESCRIPTION
PARKING CONTROLS – SEE SPECIFICATIONS LIGHT POLE / BASE - RE: ELECTRICAL FOR DETAILS PARKING DIRECTIONAL ARROW - YELLOW PARKING PAINT (TYPICAL) HANDICAP PARKING SYMBOL - PAINT COLOR AS REQUIRED BY LOCAL JURISDICTION 5 HANDICAP PARKING SIGN ON 1.5" GALVANIZED STL TUBE POST - SEE SHEET A1.20 6 PARKING STRIPPING - 4" WIDE YELLOW PAINT (TYPICAL) 8 LANDSCAPED PARKING ISLAND - SEE LANDSCAPE DRAWINGS 9 CMU / METAL PANEL SCREEN WALL - SEE SHEET A1.20 10 EMERGENCY GENERATOR ON CONCRETE PAD - SEE SHEET A1.20 11 TRANSFORMER ON CONCRETE PAD - SEE SHEET A1.20
KEYNOTES - SITE PLAN #
SITE PLAN SYMBOLS LEGEND
12 CONC. FILLED STL PIPE BOLLARD (TYPICAL) - SEE SHEET A1.20 13 DETECTIBLE WARNING CONCRETE PAD INSET/ANCHORED TO CONCRETE SIDEWALK - SEE LANDSCAPE AND CIVIL 14 KNOX BOX - CONFIRM WITH LOCAL AUTHORITY FOR MOUNTING LOCATION 15 LANDSCAPE PLAZA - SEE LANDSCAPE FOR FURTHER DETAILS 17 NEW CONCRETE PAVEMENT - SEE LANDSCAPE DRAWING 19 CONCRETE CURB AND SIDEWALK - SEE CIVIL DRAWINGS 20 CONCRETE CURB - SEE CIVIL DRAWINGS FOR DETAILS/LAYOUT 22 BUILDING SOFFIT/BALCONY ABOVE 23 CANOPY STRUCTURE - N.I.C - FOR REFERENCE ONLY 25 EV CHARGING STATION - DUAL PORT - CHARGEPOINT CT4021 - SEE A1.20 FOR TYP DETAILS 26 REMOVEABLE BOLLARD 27 COLLAPSIBLE BOLLARDS 28 STORM INLET; RE: CIVIL
1.
ACCESSIBLE ROUTE
FIRE DEPARTMENT ACCESS DRIVE
2.
2-HR RATED FIRE WALL 250' FIRE HOSE LIMIT DENVER AMENDMENT 503.1.1
PROPERTY LINE EXTENT OF WORK SOFFIT OVERHANG CORNICE OVERHANG
TRUCK
FIRE DEPARTMENT TRUCK
C
COMPACT PARKING STALL
EXIT
ACCESSIBLE EXIT & ENTRANCE INDICATES ACCESSIBLE PARKING STALL PATH OF TRAVEL FOR FIRE TRUCK
3.
4.
5.
DO NOT DISTURB, DAMAGE OR DISRUPT ANY CONDITION OUTSIDE THE WORK AREA UNLESS SPECIFICALLY DIRECTED. VERIFY EXTENT OF WORK AREA WITH OWNER. PROVIDE PROTECTION TO THE EXISTING SIDEWALK, CURB, AND GUTTER. DO NOT DISTURB, DAMAGE OR DISRUPT ROADS, STREETS, ETC. THE SITE CAN BE USED FOR STAGING AREA, SIZE AND LOCATION TO BE DETERMINED BY OWNER AND GENERAL CONTRACTOR. GENERAL CONTRACTOR SHALL FOLLOW OWNER'S RULES AND RESTRICTIONS REGARDING USE OF SITE. CONSTRUCTION FENCE TO BE OF 6 FT. HIGH CHAIN LINK, TO PREVENT UNAUTHORIZED ACCESS TO THE SITE. PROVIDE GATES AS NECESSARY FOR ENTRY/EXIT TO THE STAGING AREA. THE CIVIL ENGINEERING DRAWINGS SHOW SERVICE CONNECTIONS OUTSIDE THE BUILDING. ALSO SHOWN ARE THE LOCATION OF MAIN LINES IN AND AROUND THE SITE. GENERAL CONTRACTOR SHALL HAVE ALL UTILITIES MAIN LINES THAT ARE TO RECEIVE CONNECTIONS, AND ALL UTILITIES WITHIN
6. 7.
8.
9.
SITE AREA (WHETHER ABOVE OF BELOW GROUNDOR AT THE SURFACE) LOCATED AND PROVIDE PERMANENT MARKINGS FOR THE LIFE OF THE PROJECT. ALL UTILITIES SO DESIGNATED SHALL BE PROTECTED AND NOT DISTURBED, DAMAGED OR DISRUPTED. EXISTING FIRE HYDRANTS SHALL REMAIN. PROTECT AND MAINTAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS OF THE JOB SITE. IF ANY DISCREPANCIES OCCUR THE CONTRACTOR SHALL NOTIFY THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. DISCONNECT & REMOVE EXISTING UTILITY LINES IN THE CONSTRUCTION AREA WHICH ARE NO LONGER IN SERVICE. REPAIR ANY DAMAGE TO EXISTING UTILITY LINES STILL IN SERVICE CAUSED BY CONSTRUCTION OPERATIONS. SEE LANDSCAPE PLAN FOR LOCATIONS OF TREES, GRASS AREAS, GROUNDCOVER AND LANDSCAPE FEATURES.
1
KEY PLAN
SITE PLAN NOTES
DESCRIPTION
SCALE: 1" = 20'-0"
10. SEE CIVIL GRADING AND DRAINAGE PLANS FOR EXISTING AND PROPOSED CONTOURS, DRAINAGEVOLUMES, INVERTS AND PERIMETERDRAIN SYSTEM LOCATIONS. 11. SLOPE GRADING FROM BUILDING PER SOILS REPORT RECOMMENDATIONS UNLESS NOTED OTHERWISE - RE: CIVIL DRAWINGS. 12. RE: CIVIL DRAWINGS FOR EASEMENT LOCATIONS. 13. RE: SOILS REPORT AND CIVIL DRAWINGS FOR FOUNDATION DRAIN REQUIREMENTS. 14. RE: CIVIL DRAWINGS FOR RAMP LOCATIONS. RE: A9.40 SERIES SHEETS FOR HANDRAIL DETAILS FOR ALL STAIRS & RAMPS. 15. RE: G1.0 FOR ABBREVIATIONS AND GRAPHIC SYMBOLS. 16. RE: G1.0 FOR GENERAL NOTES APPLICABLE TO THE ENTIRE PROJECT. 17. PROVIDE SIGNAGE PER I.B.C. CHAPTER 11 AT ACCESSIBLE PARKING AND BUILDING ENTRANCES.
ARCHITECTURAL SITE PLAN
COPYRIGHT C
A1.10