UP TO On Electronic Fluorescent Ballasts, Compact Fluorescent Ballasts, Electronic HID Ballasts and LED Recessed Retrofit Kits
www.lightingandpowertech.com
L
ON
0
3.0 3 $ Y
Electronic HID Ballasts Code: 80104
20W for HID Lamps (M156, C156, C175, M175) HQEB-MH20/120LA2F
22W, MH Side Leads Electrical Characteristics Parameter
Symbol
Conditions
Min
Nom
Max
Unit
Line voltage
UN
AC
108
120
132
V
AC
96
—
144
V
Nominal and ±variations, after work stable
18
20
22
Nominal and ±variations, after work stable
—
—
4
50
—
60
Hz
0.18
0.21
0.22
A
Nominal and ±variations, after work stable
0.95
—
—
Nominal and ±variations, after work stable
—
—
1.3
Nominal and ±variations, after work stable
165
—
185
3
—
4
0.5
—
—
—
—
15
Perm.voltage fluctuations Lamp wattage
PL
Losses Line frequency
fN
Line current
IN
Power factor
λ
Crest Factor
CF
Operating frequency
at 120V
Ignition voltage Pulse width of Ignition voltage
Ignition voltage at 2.7KV
wiring length
W W
Hz KV uS feet
temperature at point tc
tc
—
—
80
℃
ambiemt temperature ta
ta
-20
—
+50
℃
—
—
ta=50℃
50000
2nd Harmonic
-
25℃, Nominal Input
—
—
2
%
3rd Harmonic
-
25℃, Nominal Input
—
—
30*λ
%
5th Harmonic
-
25℃, Nominal Input
—
—
10
%
—
7
%
Life time
h
7th Harmonic
-
25℃, Nominal Input
—
9th Harmonic
-
25℃, Nominal Input
—
—
5
%
25℃, Nominal Input
—
—
3
%
11~39th Harmonic
-
Wiring Diagram & Dimensions
7101 Whisperfield Dr. Plano, TX 75024 PH: 972-624-5000 Fax; 972 624-5800 Tech Support: 877 666-5267 sales@lightingandpowertech.com www.lightingandpowertech.com
Y
L ON
00
. $11
Compact Fluorescent Ballasts Code: 80204 Ballast Type Starting Method Lamp Connection Input Voltage Input Frequency
Model: DBC242MVRSN ELECTRICAL SPECIFICATIONS: Lamp Type
CFTR42W/GX24q
CFTR32W/GX24q
CFQ26W/G24q, CFTR26W/GX24q
CFS28W/GR10q
CFM36W/2G10
FT40W/2G11
FT39W/2G11
FT36W/2G11
FT24W/2G11
No. of Lamp 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1
FT55W/2G11
1
CFS55W/GRY10q-3
1
FC9T5 22W
FC12T5 40W
2 1 2 1
CFTR57W/GX24q
1
CFTR70W/GX24q
1
FC9T5+FC12T5
1+1
Volts
Input Watts
120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277
94 93 47 47 63 63 42 42 54 54 32 32 61 61 34 34 62 61 33 33 82 82 45 45 82 82 45 45 66 65 37 37 54 54 27 28 44 44 34 33 52 52 25 26 77 77 39 40 58 58 73 73 67 67
Input Current (Amps) 0.77 0.38 0.40 0.18 0.53 0.23 0.35 0.13 0.45 0.21 0.27 0.13 0.53 0.23 0.29 0.14 0.52 0.23 0.28 0.13 0.69 0.30 0.37 0.17 0.69 0.30 0.37 0.17 0.55 0.24 0.31 0.14 0.45 0.20 0.22 0.11 0.37 0.17 0.29 0.13 0.44 0.19 0.21 0.10 0.64 0.28 0.33 0.15 0.49 0.22 0.61 0.27 0.55 0.25
Electronic Programmed Start Series 120-277Vac ± 10% 50 / 60Hz
Power Factor
Crest Factor
Ballast Factor
0.99 0.98 0.99 0.96 0.99 0.98 0.99 0.96 0.99 0.97 0.99 0.95 0.99 0.97 0.99 0.93 0.99 0.97 0.99 0.94 0.99 0.98 0.99 0.96 0.99 0.98 0.99 0.96 0.99 0.98 0.99 0.95 0.99 0.97 0.99 0.92 0.99 0.96 0.99 0.94 0.99 0.97 0.99 0.92 0.99 0.98 0.99 0.95 0.99 0.97 0.99 0.97 0.99 0.98
<1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7
1.00 1.00 1.00 1.00 0.95 0.95 0.96 0.96 0.90 0.90 1.00 1.00 0.98 0.98 1.00 1.00 0.78 0.78 0.81 0.81 0.95 0.95 1.00 1.00 0.95 0.95 1.00 1.00 0.80 0.80 0.88 0.88 1.00 1.00 1.00 1.00 0.70 0.70 0.60 0.60 1.10 1.10 1.05 1.05 0.86 0.86 0.86 0.86 1.00 1.00 1.00 1.00 0.90 0.90
Ballast Efficacy Factor 1.06 1.08 2.13 2.13 1.51 1.51 2.29 2.29 1.67 1.67 3.13 3.13 1.61 1.61 2.94 2.94 1.26 1.28 2.45 2.45 1.16 1.16 2.22 2.22 1.16 1.16 2.22 2.22 1.21 1.23 2.38 2.38 1.85 1.85 3.70 3.57 1.59 1.59 1.76 1.82 2.12 2.12 4.20 4.04 1.12 1.12 2.21 2.15 1.72 1.72 1.37 1.37 1.34 1.34
Max. THD % 10 10 10 12 10 10 10 12 10 12 10 15 10 12 10 15 10 12 10 15 10 10 10 12 10 10 10 12 10 10 10 15 10 12 10 15 10 12 10 15 10 12 10 15 10 10 10 15 10 12 10 12 10 10
PERFORMANCE: -
APPROVALS:
Sound Rated: A Minimum Starting Temperature: 0℉, -18℃ Maximum Case Temperature: 194℉, 90℃ Meets FCC Part 18 (Class A) Non-Consumer Limits Transient Protection meets ANSI/IEEE C62.41 Cat. A Ballast frequency for all listed lamps > 40KHz 5-Year Warranty
- UL, cUL 935 Listed - UL “HL” rated for hazardous locations - RoHS compliance
PHYSICAL DIMENSIONS: Length (L): Width (W): Height (H): Mounting(M):
5.00” 3.00” 1.38” 4.63”
Options: also available versions - without studs - with lead wires
HOT SPOT LOCATION:
WIRING DIAGRAM:
3.0” BLACK
BALLAST
LINE
BLUE
BLUE
WHITE YELLOW
1 LAMPS
2 LAMPS
WHITE RED
GREEN
Single lamp omit Yellow Connections
RED
Two Lamp Applications
BLACK
Single Lamp Application
GREEN
1.0”
BLUE BLUE YELLOW YELLOW RED RED
95
L ON
6. Y$
T8 Electronic Fluorescent Ballasts Code: 80213 · Parallel Lamp Operation
DB-332N-MV-TP-HE 3 or 2 Lamp
· Active Power Factor Correction
· Instant Start
Lamp Type
Min. Start
Vin
· Line Voltage: 120-277V 50/60Hz Iin
Pin
ATHD
PF
CF
≥
≤
0.98
Type
No.
Watts
Temp. (F/C)
(V)
(A)
(W)
≤%
* F32T8
3
32
0/-18
120
0.71
84
10
BF
BEF
1.7
0.88
1.05
FB32T8
3
32
0/-18
120
0.71
84
10
0.98
1.7
0.88
1.05
FB31T8
3
31
0/-18
120
0.67
80
10
0.98
1.7
0.88
1.10
FB28T8
3
28
0/-18
120
0.60
72
10
0.98
1.7
0.88
1.22
F32T8/ES/30
3
30
0/-18
120
0.65
79
10
0.98
1.7
0.88
1.11
F32T8/ES/28
3
28
0/-18
120
0.60
72
10
0.98
1.7
0.88
1.22
F32T8/ES/25
3
25
0/-18
120
0.56
68
10
0.98
1.7
0.90
1.32
68
10
0.98
1.7
0.90
1.32
0.98
1.7
F25T8
3
0/-18
25
120
0.56
F17T8
3
17
0/-18
120
0.38
45
10
0.92
2.04
F40T8
2
40
32/0
120
0.65
78
10
0.98
1.7
0.95
1.22
0.98
1.7
0.99
1.57
0.98
1.7
0.99
1.57
F32T8
2
32
0/-18
120
0.53
63
10
FB32T8
2
32
0/-18
120
0.53
63
10
FB31T8
2
31
0/-18
120
0.51
61
10
0.98
1.7
0.99
1.62
FB28T8
2
28
0/-18
120
0.45
54
10
0.98
1.7
0.99
1.83
F32T8/ES/30
2
30
0/-18
120
0.48
59
10
0.98
1.7
0.99
1.67
F32T8/ES/28
2
28
0/-18
120
0.45
54
10
0.98
1.7
0.99
1.83
F32T8/ES/25
2
25
0/-18
120
0.43
51
10
0.98
1.7
1.00
1.95
F25T8
2
25
0/-18
120
0.42
50
10
0.98
1.7
1.00
1.96
* F32T8
3
32
0/-18
277
0.31
83
10
0.98
1.7
0.88
1.06
FB32T8
3
32
0/-18
277
0.31
83
10
0.98
1.7
0.88
1.06
FB31T8
3
31
0/-18
277
0.29
79
10
0.98
1.7
0.88
1.11
0.88
1.25
0.88
1.14
FB28T8
3
28
0/-18
277
0.26
70
15
0.98
1.7
F32T8/ES/30
3
30
0/-18
277
0.28
77
15
0.98
1.7
F32T8/ES/28
3
28
0/-18
277
0.26
70
15
0.98
1.7
0.88
1.25
F32T8/ES/25
3
25
0/-18
277
0.245
68
15
0.97
1.7
0.90
1.32
F25T8
3
25
0/-18
277
0.24
66
15
0.97
1.7
0.90
1.38
F17T8
3
17
0/-18
277
0.17
45
15
0.96
1.7
0.92
2.04
0.97
1.7
F40T8
2
40
32/0
277
0.29
77
15
0.95
1.23
F32T8
2
32
0/-18
277
0.24
63
15
0.97
1.7
0.99
1.57
FB32T8
2
32
0/-18
277
0.24
63
15
0.97
1.7
0.99
1.57
FB31T8
2
31
0/-18
277
0.22
60
15
0.97
1.7
0.99
1.65
FB28T8
2
28
0/-18
277
0.20
53
15
0.97
1.7
0.99
1.86
0.99
1.70
0.99
1.86
F32T8/ES/30
2
30
0/-18
277
0.21
58
15
0.97
1.7
F32T8/ES/28
2
28
0/-18
277
0.20
53
15
0.97
1.7
1.00
1.95
1.00
1.96
F32T8/ES/25
2
25
0/-18
277
0.19
51
15
0.97
1.7
F25T8
2
25
0/-18
277
0.18
50
15
0.96
1.7
Note:
The above data is tested at 60Hz. The lamp with “*” is the main lamp. Application and Performance Specification Information Subject to Change without Notification.
7101 Whisperfield Drive. Plano TX 75024 877-666-5267 sales@lightingandpowertech.com
PRODUCT SPECIFICATION SHEET Model #: 80213
Description: DB-332N-MV-
Performance
TP-HE Safety
· Meets ANSI Standard C82.11-2005
· No PCB’s
· Meets ANSI Standard C62.41-2002
· UL&cUL listed (Class P, Type 1 Outdoor)
· Meets FCC 18 Class A
· OCV 600V
Application
Physical Parameters
· Remote Mounting: 18 ft. max. Lead length, 18AWG · Maximum Ambient Temperature: 131℉,55℃
Length Width
9.5″ 1.3″
· Sound Rated: A · Maximum case temperature Tc:194℉,90℃
Height Weight
1.0″ 1.10 lbs
Lead Length White, Black
25″(±1″)
Red
46″(±1″)
Blue
31″(±1″)
Note: For two lamps application, cap any blue lead. Insulate to 600 volts.
7101 Whisperfield Drive. Plano TX 75024 877-666-5267 sales@lightingandpowertech.com
L
ON
50
7. Y$
Compact Fluorescent Ballasts Code: 80208
Performance Specification: Class P No PCB's Type 1 Outdoor Sound Rated Class A High Power Factor
Ballast Type
Electronic
Starting Method
Rapid Start
Lamp Connection
SERIES
Input Voltage
120V-277V
Input Frequency
50/60Hz
Lamp
Num.of
Lamp
Min.Start
Input
Input
Power
Lamp Current
Type
Lamps
Watts
Temp
Current
Power
Factor
Crest Factor
PLC26W
2
26
-18℃
0.18~0.44A
50~54W
<10%
≥0.99
<1.7
PLC42W
1
42
-18℃
0.15~0.35A
38~44W
<10%
≥0.99
<1.7
PLC32W
1
32
-18℃
0.12~0.29A
30~36W
<10%
≥0.99
<1.7
FC12T5
1
40
-18℃
0.13~0.33A
34~40W
<10%
≥0.99
<1.7
Wiring Diagram
Case
Overall(L)
Width(W)
Height(H)
Mounting(M)
128mm
61mm
26mm
109mm
7101 Whisperfield Drive, Plano, TX, 75024 Ph: 877-666-5267 Fax: 972-624-5800 sales@lightingandpowertech.com www.lightingandpowertech.com
THD
L
ON
50
6. Y$
T8 Electronic Fluorescent Ballasts Code: 80209 · Parallel Lamp Operation
DB-232H-MV-TP-HE 2 or 1 Lamp
· Active Power Factor Correction
· Instant Start
Lamp Type
· Line Voltage: 120-277V 50/60Hz
Min. Start
Vin
Iin
Pin
ATHD
PF
CF
Type
No.
Watts
Temp. (F/C)
(V)
(A)
(W)
≤%
≥
≤
* F32T8
2
32
0/-18
120
0.62
74
10
0.98
FB32T8
2
32
0/-18
120
0.62
74
10
BF
BEF
1.7
1.18
1.59
0.98
1.7
1.18
1.59
FB31T8
2
31
0/-18
120
0.58
73
10
0.98
1.7
1.18
1.61
FB28T8
2
28
0/-18
120
0.54
65
10
0.98
1.7
1.18
1.81
F32T8/ES/30
2
30
0/-18
120
0.58
69
10
0.98
1.7
1.18
1.71
F32T8/ES/28
2
28
0/-18
120
0.54
64
10
0.98
1.7
1.18
1.84
F32T8/ES/25
2
25
0/-18
120
0.53
63
10
0.98
1.7
1.18
1.87
F25T8
2
25
0/-18
120
0.45
54
10
0.98
1.7
1.20
2.20
F17T8
2
17
0/-18
120
0.33
39
10
0.98
1.7
1.23
3.15
0.98
1.7
1.35
2.49
0.98
1.7
1.38
3.06
F40T8
1
40
32/0
120
0.45
54
10
F32T8
1
32
0/-18
120
0.37
45
10
FB32T8
1
32
0/-18
120
0.37
45
10
0.98
1.7
1.38
3.06
FB31T8
1
31
0/-18
120
0.36
44
10
0.98
1.7
1.38
3.13
FB28T8
1
28
0/-18
120
0.33
39
10
0.98
1.7
1.38
3.53
F32T8/ES/30
1
30
0/-18
120
0.36
44
10
0.98
1.7
1.38
3.13
F32T8/ES/28
1
28
0/-18
120
0.33
39
10
0.98
1.7
1.38
3.53
F32T8/ES/25
1
25
0/-18
120
0.32
38
10
0.98
1.7
1.38
3.63
0.98
1.7
F25T8
1
25
0/-18
120
0.28
33
10
1.40
4.24
F17T8
1
17
0/-18
120
0.22
25
10
0.95
1.7
1.42
5.68
* F32T8
2
32
0/-18
277
0.27
73
10
0.98
1.7
1.18
1.61
FB32T8
2
32
0/-18
277
0.27
73
10
0.98
1.7
1.18
1.61
FB31T8
2
31
0/-18
277
0.25
71
10
0.98
1.7
1.18
1.66
FB28T8
2
28
0/-18
277
0.235
63
15
0.98
1.7
1.18
1.87
F32T8/ES/30
2
30
0/-18
277
0.25
69
15
0.98
1.7
1.18
1.71
F32T8/ES/28
2
28
0/-18
277
0.235
63
15
0.98
1.7
1.18
1.87
F32T8/ES/25
2
25
0/-18
277
0.23
62
15
0.97
1.7
1.18
1.90
0.97
1.7
F25T8
2
25
0/-18
277
0.20
54
15
1.20
2.22
F17T8
2
17
0/-18
277
0.15
39
15
0.96
1.7
1.23
3.15
0.97
1.7
F40T8
1
40
32/0
277
0.20
54
15
1.35
2.50
F32T8
1
32
0/-18
277
0.17
45
15
0.97
1.7
1.38
3.06
FB32T8
1
32
0/-18
277
0.17
45
15
0.97
1.7
1.38
3.06
FB31T8
1
31
0/-18
277
0.16
44
15
0.97
1.7
1.38
3.14
FB28T8
1
28
0/-18
277
0.15
39
15
0.97
1.7
1.38
3.54
1.38
3.14
1.38
3.54
F32T8/ES/30
1
30
0/-18
277
0.16
44
15
0.97
1.7
F32T8/ES/28
1
28
0/-18
277
0.15
39
15
0.97
1.7
F32T8/ES/25
1
25
0/-18
277
0.145
38
15
0.97
1.7
1.38
3.63
F25T8
1
25
0/-18
277
0.13
33
15
0.96
1.7
1.40
4.24
F17T8
1
17
0/-18
277
0.105
25
15
0.95
1.7
1.42
5.69
Note:
The above data is tested at 60Hz. The lamp with “*” is the main lamp. Application and Performance Specification Information Subject to Change without Notification.
7101 Whisperfield Drive. Plano TX 75024 877-666-5267 sales@lightingandpowertech.com
PRODUCT SPECIFICATION SHEET Model #: 80209
Description: DB-232H-MV-TP-HE
Performance
Safety
· Meets ANSI Standard C82.11-2005
· No PCB’s, Type HL
· Meets ANSI Standard C62.41-2002
· UL&cUL listed (Class P, Type 1 Outdoor)
· Meets FCC 18 Class A
· OCV 600V
Application
Physical Parameters
· Remote Mounting: 18 ft. max. Lead length, 18AWG · Maximum Ambient Temperature: 131℉,55℃
Length Width
9.5″ 1.3″
· Sound Rated: A · Maximum case temperature Tc:194℉,90℃
Height Weight
1.0″ 1.10 lbs
Lead Length White, Black
25″(±1″)
Red
46″(±1″)
Blue
31″(±1″)
Note: For one lamp application, cap any blue lead. Insulate to 600 volts.
7101 Whisperfield Drive. Plano TX 75024 877-666-5267 sales@lightingandpowertech.com
A 0702 8 : e Cod $9.90 Y L ON
LED 1100lms. 3000K/4000K 80/90CRI
Watran recessed LED downlight lights are manufactured under the ISO 9001 quality control system, which contain: high-efficiency LED, minimum color-rendering index of 80-90%, with a life of 30,000 hours. The aluminum housing makes the fixture safe, durable, and brings good heat dissipation, which make the fixture suitable for use in office rooms, shopping malls, stores, libraries, homes and other indoor locations.
80702B
80
1100
3000
80702A
90
1100
4000
(12-16)