Magnetic LED Retrofit Kit
Features ◆ DLC & cETLus listed;
Application:
◆ AC120-277V, Ra>80
• Workshop
◆ SMD2835 LED; High efficacy 130lm/w
• Factory
◆ High rebates, low import tariffs ◆ External driver ◆ Simple and secure installation, comes with quick connects for easy install
• Office • Shopping mall • supermarket
◆ An energy efficient replacement for existing T12 and T8 strip fixtures and troffers ◆ 5 years warranty ◆ Operating temperature: -20℃~45℃
CM
LED driver
1-10V Dim AC120-277V
Length
2FT 25W 4FT 36W 4FT 60W 4FT 60W
(2 strips driven by one driver) 50W (2 strips driven by one driver) (3 strips driven by one driver) (4 strips driven by one driver)
Connection Male and female connection
Magnet 1mm thickness magnet; High Impact Resistance; Rustless; Easy to install Minimized the labor costs
Parameters Efficacy
Model #
Size
Power
XSY-T8RTP25W2FT*2
2FT
25W
3250LM
XSY-T8RTP36W4FT*2
36W
4680LM
XSY-T8RTP50W4FT*2
50W
XSY-T8RTP60W4FT*3
4FT
XSY-T8RTP60W4FT*4
130LM/W
Lumen
6500LM
60W
7800LM
60W
7800LM
Ordering Guide
Driver
Multiple D riving Typ e
External
2 strips driven by one driver 2 strips driven by one driver 2 strips driven by one driver 3 strips driven by one driver 4 strips driven by one driver
Wire Input
CCT
One
4000K
end
5000K
For example: XSY-T8RTPXXWXFT*Y ZZZZ
Product name
Power
Length
Strip Qty
CCT
T8RT
PXXW
XFT
Y
ZZZZ
T8RT
25W 36W 50W 60W
2FT 4FT
2=2 strips 3=3 strips 4=4 strips
4000K 5000K
www.lightingandpowertech.com
Lighting and Power Technologies 7101 Whisperfield Drive, Plano, TX 75024 Ph: 877-666-5267 Fax: 972-624-5800 sales@lightingandpowertech.com www.lightingandpowertech.com
Accessories
PC Cover
Male and Female connector
Dimension 0.69"
19.69"
43.31"
1.26"
Installation
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
Fig. 1
Step 1:
Fig. 2
Cut off the power of the troffer retrofit kit before any operation Pull the movable bolt at the edge
Step 2: Take out the fluorescent tubes one by one.
of the troffer retrofit kit and open the cover.
www.lightingandpowertech.com
Lighting and Power Technologies 7101 Whisperfield Drive, Plano, TX 75024 Ph: 877-666-5267 Fax: 972-624-5800 sales@lightingandpowertech.com www.lightingandpowertech.com
Fig. 3
Fig. 4
Step 3:
Step 4: Dismantle the ballast and
Open the top cover of wiring box.
circuit of the fluorescent tubes .
Fig.5
Fig. 6
Step 5:
Step 6: Take out the LED driver and
A. Take out the LED Magnet Tubes
screws we provide; ďŹ x the drivers
from the package box. B. Stick the LED
onto the position of the previous
Tubes onto the troffer. Adjust its position
ballast.
to make sure they are placed horizontally in proper position.
Fig. 7
Fig. 8
Step 7:
Step 8: Connect the Connection Wire to the
Connection mode of LED Driver' s
OUTPUT terminal of the LED driver.
Input Wire(See Fig. 7): White: Live Wire Black: Null Wire Yellow/Green: Ground Wire
Fig. 9
Fig. 10
Step 10: Finish all connection between
Step 9:
LED driver and. LED strips.
Connect the Connection Wire to the LED Tubes through 2P socket one by one.
Fig. 11
Fig. 12
Step 11: Install the top cover of the wiring box to cover the LED driver.
Step 12: Pull the movable bolt at the edge of the troffer retrofit kit and close the cover slightly.
Fig. 13
Step 13: Recover the power supply and have a test. Replacement of LED Magnet Tubes is completed.
www.lightingandpowertech.com
Lighting and Power Technologies 7101 Whisperfield Drive, Plano, TX 75024 Ph: 877-666-5267 Fax: 972-624-5800 sales@lightingandpowertech.com www.lightingandpowertech.com
Package Info. Model
Carton Dimension
Qty / Carton
N.W
G.W
2FT
29.33’’*13.19’’*8.66’’
20PCS
18.5lbs
19.84lbs
4FT
56.1’’*16.14’’*7.17’’
20PCS
30.86lbs
33.07lbs
Safety Precaution To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions included with and on the fixture box and all fixture labels. Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician. For The installation: If you are unsure about the installation or maintenance of the luminaires, consult a qualified licensed electrician and check your local electrical code. To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. WARNING: RISK OF FIRE OR ELECTRICAL SHOCK Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply. Turn off the power when you perform any maintenance. Verify that supply voltage is correct by comparing it with the luminaire label information. Make all electrical and grounded connections in accordance with the National Electrical Code and any applicable local code requirements. All wiring connections should be capped with UL approved wire connectors. CAUTION: RISK OF INJURY Avoid direct eye exposure to the light source while it is on. Account for small parts and destroy packing material, as these may be hazardous to children. SUITABLE FOR DRY LOCATION
www.lightingandpowertech.com
Lighting and Power Technologies 7101 Whisperfield Drive, Plano, TX 75024 Ph: 877-666-5267 Fax: 972-624-5800 sales@lightingandpowertech.com www.lightingandpowertech.com