T12 RAPID START & INSTANT START ELECTRONIC FLUORESCENT BALLASTS


PRODUCT SPECIFICATION SHEET Model #: 80205

Description: DB-240-RS-MV

Line Voltage:120-277V 50/60Hz

Rapid Start

Series Lamp Operation

Active Power Factor Correction

Lamp Type

Min. Start

Vin

Iin

Pin

ATHD

PF

CF

Type

No.

Watts

Temp. (F/C)

(V)

(A)

(W)

≤%

*F40T12

2

40

32 / 0

120

0.62

72

10

0.98

F34T12

2

34

32/ 0

120

0.55

62

10

0.98

F30T12

2

30

32 / 0

120

0.48

58

10

BF

BEF

1.7

0.85

1.18

1.7

0.85

1.37

0.98

1.7

0.93

1.60

F25T12

2

25

32 / 0

120

0.58

70

10

0.98

1.7

1.10

1.57

*F40T12

2

40

32 / 0

277

0.26

70

10

0.98

1.7

0.85

1.21

F34T12

2

34

32 / 0

277

0.23

61

10

0.98

1.7

0.85

1.39

F30T12

2

30

32 / 0

277

0.20

56

10

0.98

1.7

0.93

1.66

F25T12

2

25

32 / 0

277

0.24

69

10

0.98

1.7

1.10

1.59

Note :The above data is tested at 60 Hz. The Operating Frequency: 40 kHz – 53 kHz; the main lamp frequency : 45 kHz. Application and Performance Specification Information Subject to Change without Notification.

Performance

Safety

Meets ANSI Standard C82.11-2005

No PCB’s, Type HL

Meets ANSI Standard C62.41-2001

UL & cUL listed (Class P, Type 1 Outdoor)

Meets FCC 18 Non CONSUMER Limits

OCV 600V

Application

Physical Parameters

Remote Mounting: 18 ft. max. Lead length, 18AWG Maximum Ambient Temperature: 131℉,55℃

Length

9.5″

Width

1.3″

Sound Rated: A Maximum Case Temperature: 194℉,90℃

Height

1.0″

Weight

1.1 lbs

Lead Length White, Black

25″(±1″)

Red, Blue

31″(±1″)

Yellow

46″(±1″)

*For 1 lamp operation wire 1 socket with 2 red leads and opposite socket wire with 2 blue leads. Cap off 2 yellow wires individually.


APPLICATION and PERFORMANCE SPECIFICATION Code: 80206 ·Line Voltage:120V/277V 50/60hz

·Instant Start

·Parallel Lamp Operation

·Active Power Factor Correction

Description: DB-275-IS-MV

Lamp Type

Min. Start

Vin

Iin

Pin

ATHD

PF

CF

Type

No.

Watts

Temp. (F/C)

(V)

(A)

(W)

≤%

BF

BEF

F96T12

2

75

32/0

120

1.17

137

10

0.98

1.70

0.90

0.66

F96T12/ES

2

60

32/0

120

0.88

105

10

0.98

1.70

0.89

0.85

F72T12

2

55

32/0

120

0.91

108

10

0.98

1.70

0.92

0.85

F48T12/CW

2

39

32/0

120

0.61

73

10

0.98

1.70

0.96

1.32

F96T12

1

75

32/0

120

0.70

84

10

0.98

1.70

0.95

1.13

F96T12/ES

1

60

32/0

120

0.53

63

10

0.98

1.70

0.93

1.47

F72T12

1

55

32/0

120

0.55

64

10

0.98

1.70

0.96

1.50

F48T12/CW

1

39

32/0

120

0.39

47

10

0.98

1.70

1.10

2.34

F96T12

2

75

32/0

277

0.50

135

10

0.98

1.70

0.90

0.67

F96T12/ES

2

60

32/0

277

0.38

103

10

0.98

1.70

0.89

0.86

F72T12

2

55

32/0

277

0.40

107

10

0.98

1.70

0.92

0.86

F48T12/CW

2

39

32/0

277

0.27

72

10

0.96

1.70

0.96

1.33

F96T12

1

75

32/0

277

0.31

83

10

0.95

1.70

0.95

1.14

F96T12/ES

1

60

32/0

277

0.24

63

10

0.95

1.70

0.93

1.47

F72T12

1

55

32/0

277

0.25

64

10

0.95

1.70

0.96

1.50

F48T12/CW

1

39

32/0

277

0.18

46

12

0.92

1.70

1.10

2.39

Note: the above data is tested at 60Hz. Application and Performance Specification Information Subject to Change without Notification.

Performance

Safety

Meets ANSI Standard C82.11-2005

No PCB’s,Type HL

Meets ANSI Standard C62.41-2001

UL&cUL listed (Class P, Type 1 Outdoor)

Meets FCC Part 18 Class A

OCV 750V

Application

Physical Parameters

Remote Mounting: 18 ft. max. Lead length, 18AWG

Length

9.5″

Maximum Ambient Temperature: 131℉,55℃

Width

1.7″

Sound Rated:

A

Height

1.2″

Maximum case temperature Tc:194℉,90℃

Weight

1.7 lbs

Lead Length

Mounting:

8.9″

White, Black

25″(±1″)

Red

79″(±1″)

Blue

46″(±1″)

Nov 28, 2013 REV: 04 7101 Whisperfield Drive, Plano, TX, 75204 Ph: 877-666-5267 Fax: 972-624-5800 sales@lightingandpowertech.com www.lightingandpowertech.com


APPLICATION and PERFORMANCE SPECIFICATION

INPUT

Tc

OUTPUT

Note: For one lamp application, cap any blue lead. Insulate to 750 volts.

Nov 28, 2013 REV: 04 7101 Whisperfield Drive, Plano, TX, 75204 Ph: 877-666-5267 Fax: 972-624-5800 sales@lightingandpowertech.com www.lightingandpowertech.com


APPLICATION and PERFORMANCE SPECIFICATION Code: 80224 · Line Voltage:120-277V 50/60Hz

· Program Start

· Series Lamp Operation Description: DB-2110-RS-MV

· Active Power Factor Correction

Lamp Type

Min. Start

Vin

Iin

Pin

ATHD

PF

CF

Type

No.

Watts

Temp. (F/C)

(V)

(A)

(W)

≤%

* F96T12/HO

2

110

-20/-29

120

1.54

185

10

0.98

F96T12/HO/ES

2

95

0/-18

120

1.38

165

10

F72T12/HO

2

85

-20/-29

120

1.17

140

10

F60T12/HO

2

75

-20/-29

120

0.98

117

10

0.98

1.7

0.82

0.70

F48T12/HO

2

60

-20/-29

120

0.80

96

10

0.98

1.7

0.83

0.86

F96T12/HO

1

110

-20/-29

120

0.80

96

10

0.98

1.7

0.91

0.95

F96T12/HO/ES

1

95

0/-18

120

0.74

88

10

0.98

1.7

0.91

1.03

BF

BEF

1.7

0.88

0.48

0.98

1.7

0.88

0.53

0.98

1.7

0.85

0.61

* F96T12/HO

2

110

-20/-29

277

0.66

180

10

0.97

1.7

0.88

0.49

F96T12/HO/ES

2

95

0/-18

277

0.60

162

10

0.97

1.7

0.88

0.54

F72T12/HO

2

85

-20/-29

277

0.50

137

10

0.97

1.7

0.85

0.62

F60T12/HO

2

75

-20/-29

277

0.42

114

10

0.97

1.7

0.82

0.71

F48T12/HO

2

60

-20/-29

277

0.34

94

10

0.97

1.7

0.83

0.87

F96T12/HO

1

110

-20/-29

277

0.37

95

15

0.90

1.7

0.91

0.96

F96T12/HO/ES

1

95

0/-18

277

0.32

86

15

0.90

1.7

0.91

1.04

Note:

The above data is tested at 60Hz. The ballast BLE can meet DOE

The lamp with “*” is the main lamp.

energy conservation standards with main lamp.

Application and Performance Specification Information Subject to Change without Notification.

Performance

Safety

· Meets ANSI Standard C82.11-2005

· No PCB’s, Type HL, Type CC

· Meets ANSI Standard C62.41-2002

· UL&cUL listed (Class P, Type 1 Outdoor)

· Meets FCC 18 Class A

· OCV 387V

· Meets DOE energy conservation standards Application

Physical Parameters

· Remote Mounting: 18 ft. max. Lead length, 18AWG

Length

9.5″

· Maximum Ambient Temperature:

Width

2.3″

Height

1.6″

Weight

2.4 lbs

· Sound Rated:

55℃

A

· Maximum case temperature Tc:90℃

Lead Length White, Black

25″(±1″)

Red, Blue

46″(±1″)

Yellow

79″(±1″)

Expected Lifetime 50% survival after 50000 hours' operation Ambient temperature (Ta) 40C maximum, and maximum case temperature 75C

Product Warranty Period 5 years from production date

Nov 26, 2013 REV:02 7101 Whisperfield Drive, Plano, TX, 75056 Ph: 877-666-5267 Fax: 972-624-5800 sales@lightingandpowertech.com www.lightingandpowertech.com


APPLICATION and PERFORMANCE SPECIFICATION

Note: For one lamp application, connect red & blue leads to one lamp.

Nov 26, 2013 REV:02 7101 Whisperfield Drive, Plano, TX, 75056 Ph: 877-666-5267 Fax: 972-624-5800 sales@lightingandpowertech.com www.lightingandpowertech.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.