Latera Acute hospital bed with a lateral tilt

Logo Latera základní varianta loga

HEALTHCARE PROGRAM


hospital bed with a lateral tilt

Latera Acute – think laterally… Routine nursing activities often require physical handling of the patient several times a day, often in non-ergonomic positions. LINET has developed the Latera Acute patient bed with a lateral tilt to turn the patient with little physical exertion, minimising excessive physical strain and the risk of injury.

LATERAL TILT Reduces the physical strain for nursing staff when handling patients. Reduces the risk of occupational injury. Routine nursing activities can be performed more efficiently. Effective management of pressure ulcers. Helps prevent complications in patients with lymphoedema and facilitates post-operative drainage. Helps prevent the negative effects of immobilisation. Helps increase the quality of life for long-term or permanently immobile patients.

2


Logo Latera základní varianta loga

varianty umístění na postel

projekt: Logo Latera zákazník: Linet datum: 16. 5. 2007

SAVING ENERGY – USE UP 10× LESS FORCE The force required to turn a patient on the Latera Acute is 10 times lower in comparison with a standard patient bed.

20% TIME SAVED The time required for completing activities on the Latera Acute such as changing bed linen is reduced by up to 20% in comparison with a standard patient bed.

3


hospital bed with a lateral tilt

Lateral tilt in nursing The benefits of the Latera Acute for daily nursing activities are subject to two basic prerequisites: The adjustment of the lateral tilt is safer for patients The lateral tilt adjustment is easy and reliable for nursing activities

SIMPLE AND RELIABLE CONTROL Staff are able to effectively position the patient bed using conveniently located control panels.

SAFETY GO BUTTON The safety GO button enhances patient safety by preventing unintentional bed positioning. The GO button activates the bed controls for 3 minutes. Three minutes after the button is pressed, the controls automatically deactivate so any bed positioning will only occur after intentional activation.

15º LATERAL TILT The Latera Acute has a 15 degree lateral tilt which enables the patient to be turned to the side with the minimum of effort. COLUMN CONSTRUCTION The three-column construction enables lateral tilt adjustment and provides the bed with exceptional stability and rigidity.

SUPERVISOR CONTROL PANEL Ergonomically shaped with clear panel graphics the supervisors control panel is centrally located for ease of access.

PATIENT HANDSET CONTROL A practical control for the patient and nurse contains controls for the bed’s basic positions, including backrest tilt and adjustment of the mattress platform height.

SATELLITE CONTROL PANEL Symbols for controlling individual functions are large and clearly visible. The buttons are distinguished by various colours with embossed symbols.

4

LATERAL TILT FOOT CONTROL Foot controls are located on the bed undercarriage on both sides enabling practical and easy hands-free adjustment of the lateral tilt.


SAFE LATERAL TILT The unique three-column construction of the Latera Acute ensures stability for lateral tilt adjustment and smooth, stable and efficient movement. LATERA POSITIONING CUSHION The Latera positioning cushion can be used during patient positioning to protect the patient against pressure ulcers and direct contact with the side rail.

PROCEDURE FOR MAKING THE BED WITH A LATERAL TILT Changing bed linen is just one way in which the lateral tilt can be effectively used.

1. The nurse can adjust the bed to a safe working height and thus can maintain the correct working posture.

2. The side rail closest to the nurse is raised a positioning cushion allows the patient to rest against it. Using the foot controls the nurse can tilt the bed laterally.

3. The lateral tilt transfers the patient’s centre of gravity substantially reducing the work required to turn the patient onto their side. Heavier patients can be turned with the minimum of effort.

4. With the patient’s position stable, the nurse can fully devote their time to changing the bed linen from the other side of the bed.

5. Using the foot controls, the nurse can adjust the bed to the horizontal position, turn the patient onto their back, raise the other side rail and place a Latera positioning cushion against it to protect the patient. FOOT CONTROLS Foot controls for height adjustment and examination position are equipped with a mechanical guard which prevents accidental activation.

6. The patient can then be turned onto their other side with the aid of the lateral tilt and the nurse can finish changing the bed linen on the other side of the bed.

5


hospital bed with a lateral tilt

Effective hospital infection prevention Effective prevention of hospital infections are based upon thorough decontamination and complete hygiene of all surfaces on the wards including the bed itself. The simple construction and use of joint-free technology ensures that the Latera Acute is very easy to clean and decontaminate.

Most hospital infections are spread by staff, patients and visitors by touch. The side rails and head and foot boards of beds are particular area’s that will come into constant contact with staff and patients. The joint-free technology used on the Latera Acute ensures that these areas are without joints and have a smooth and non-absorbent surface, thus ensuring that they are easy to clean and wipe down.

COLUMN CONSTRUCTION The column lifting units of the Latera Acute maximise the ease of cleaning and decontamination procedures preventing the infiltration of dangerous substances. The columns consist of smooth aluminium profiles without difficult to clean gaps and joints. Columns can be easily wiped down and cleaned. The construction allows unrestricted access to all the bed parts.

6


Easily removable mattress platform covers enable easy access to other parts of the bed.

Ventilation holes within mattress platform cover allow for air circulation and are easy to wash and clean.

Use of foot pedals for height adjustment and lateral tilt ensure hands free adjustment of the bed in order to limit the risk of infection.

HOSPITAL ACQUIRED INFECTION Despite advances in modern medicine there is a constant struggle with the increased risk of secondary infections. According to the World Health Organisation, more than 17 million people die of infectious diseases every year, while a great number of these infections are associated with nosocomial – hospital acquired infections. Constantly more frequent invasive procedures and excessive administration of antibiotics (resulting in resistance) give rise to nosocomial infections. Nosocomial infections are among the ten most common causes of death in the world. Infections contracted during a stay in hospital prolong and make a patient’s treatment more expensive, and increase their physical suffering. Medical staff are also exposed to the risk of hospital infections. Up to 30 percent of hospital infections can be avoided through adequate prevention.

7


hospital bed with a lateral tilt

Configuration and technical parameters SPECIFICATIONS Fully electric bed with column construction Safe Working Load (SWL) 200 kg/31,5 stone 4-section ABS plastic mattress platform ¾ length collapsible siderails Auto-regression Auto-contour CPR mechanical release for lowering backrest Removable ABS head and foot boards with safety locks Bed extension Patient handset control Supervisor control panel inc. 4-position memory – CPR, cardiac chair, examination position and Trendelenburg Foot controls for lateral tilt adjustment Hi-Lo foot controls Safety control with GO button Battery back-up with an intelligent charger and diagnostic service-life Integrated linen shelf 150 mm diameter Tente castors, central brake Protective corner bumpers ABS undercarriage covers

1

SIDERAILS ¾ length collapsible siderails provide patient protection against a fall and stability of the patient in a lateral position.

2

HEAD & FOOT BOARDS Removable ABS head and foot boards enable quick access to the patient in emergency situations and also assist ease of hygiene. The décor of the panel can be supplied in various shades from the LINET range. End locks prevent the boards from being removed unintentionally.

1

2

OPTIONAL FEATURES 5th castor Under bed safety night light Satellite control

4

7

3

3

SUPERVISOR CONTROL PANEL The supervisor control panel can adjust the bed in all positions. It contains a memory for the most frequently used positions, GO button, STOP button and battery capacity and lifetime indicator.

4

BED EXTENSION The integrated bed extension allows the adjustment of the mattress platform length to meet the patient’s individual height.

Logo Latera základní varianta loga

8

varianty umístění na postel


5

SATELLITE CONTROL Ergonomically designed control on a flexible arm is always accessible for both nurse and patient.

6

MATTRESS PLATFORM Four-section profiling mattress platform with removable, easily washable ABS covers.

7

COLUMNS The three-column construction ensures perfect stability with smooth and efficient movement for height adjustment, lateral tilt and other positions.

8

FOOT CONTROLS Bed height and lateral tilt controls are placed on both sides of the bed. The controls are protected against unintentional activation by a mechanical barrier. Safety GO activation and security lock-outs provide additional safety.

9

CASTORS 150 mm diameter Tente castors.

10

5TH CASTOR The central 5th castor significantly eases the handling of the bed during transportation and is controlled separately by a foot lever.

5

6

7

8

9

10

TECHNICAL DATA

ELECTRICAL DATA

External dimensions 2190 x 985 mm Bed extension/reduction ±125 mm Mattress dimensions 2000×860 mm Mattress platform Min 430 mm, height adjustment Max 810 mm Lateral tilt 15° TR/RTR tilt ± 16° Backrest tilt 0°–70° Knee-break 0°– 45° Safe Working Load (SWL) 200 kg/31,5 stone

Supply voltage Maximum input

230 V, ±10 %, 50–60 Hz max. 1,6 A 370 VA Cover against water and dust penetration IP54 Electrical safety classification Class I Type B

CERTIFICATES LINET is a company certified under European norms and quality systems: EN ISO 9001:2008, EN ISO 13485:2003, EN ISO 14001:2004 The products are produced under European norms for medical technology and hospital beds: EN 60601-1 EN 60601-1-2 EN 60601-1-6 EN 60601-2-52

9


hospital bed with a lateral tilt

Accessories The Latera Acute can be equipped with a broad range of accessories that will increase the functionality of the patient bed.

Infusion stand

Oxygen bottle holder

Towel holder

10

Lifting pole with handle

Plastic lifting pole handle

Writing shelf

Latera positioning cushion

Cannulae holder

Urine bag holder with tilt adjustment

Universal stainless steel bar (26 cm)

Side rail bumpers


CHOICE OF COLOURS The Latera Acute bed design meets the latest aesthetic trends in healthcare.

COLOUR RANGE 1. Light blue 2. Nectarine 3. Kiwi 4. Yellow 5. Aquamarine

2.

3.

1.

4.

5.

A.

B.

C.

WOODEN PANELS Although the Latera Acute is a hospital bed, it offers not only a modern range of colours, but also wooden decors.

WOOD DECORS A. Royal maple B. Beech C. Cognac pear

hospital bed with lateral tilt

Your choice of design

Latera Thema nursing bed with a lateral tilt

LATERA THEMA

Latera Thema is a bed with lateral tilt intended for nonacute and nursing home use. The siderails and bed ends are made of aluminium which gives the bed an aesthetically modern design.

The three-column construction enables LT adjustment and provides the bed with exceptional stability, rigidity and also a specific design.

11


LINET UK Ltd, 11 Brunel Way, Segensworth East, Fareham, Hampshire, PO15 5TX tel: 0844 248 1833, fax: 0844 499 4409, e-mail: info@linet.uk.com, web: www.linet.uk.com

12/2014 9601-1019-02  

Slight colour deviations are possible. Technical alterations reserved.

hospital bed with a lateral tilt