AWG RE

Page 1

Sources of power come in many forms and all sizes.

Powerful solutions for power come from AWG

Power Cables Bare Aluminum Conductors Substation Control Cables Service Drop Cables Guy Wire/Static Wire Bare Copper Ground Wire Copper-Clad/Alumo-Clad Cables OPGW & Fiber Cables

Unconventional. Uncommon. Unbeatable.


Renewable Energy Table of Contents Bare Aluminum Code Name Finder

002

MEDIUM VOLTAGE CABLES URD 345 Mil TRXLP 35kV/PowerGuard™

312

LOW VOLTAGE CABLES TowerGuard CCA® DLO 2kV TowerGuard XLP 2kV Type DLO Diesel Locomotive Cable 2kV SunGuard 1000 1kV

201 202 709 203

GROUNDING CABLES/STATIC WIRE Bare Copper Tinned Copper Copper-Clad Steel Wire Alumo-Clad Steel Wire Type M Alumo-Clad Steel Wire Guy Strand

101 102 104 105 106

TRANSMISSION/T-LINE & DISTRIBUTION CABLES Bare Aluminum Cables ACSR 401 AAC 403 AAAC 6201 Alloy 404 TP Twisted Pair 405 Packaging Information ACSR and ACSR/AW 410 AAC 411 AAAC 6201 Alloy 412 TP Twisted Pair 413 Galvanized Guy Wire 107 OPGW/FIBER OPTIC CABLES OPGW Optical Ground Wire OPGW Cable & System Information Guide for Hardware Selection ADSS Fiber Optic Cable Loose Tube Fiber Optic Cable Duct

CONTROL CABLES Control Cable FR-XLPE Insulated Conductors, CPE Jacket 600V Control Cable FR-XLPE Insulated Conductors, Copper Shield, CPE Jacket 600V Control Cable FR-EPR Insulated Conductors, CPE Jacket 600V Control Cable FR-EPR Insulated Conductors, Copper Shield, CPE Jacket 600V 20/10 Control Cable, PE/PVC Insulated Conductors, PVC Jacket 600V 20/10 Control Cable, PE/PVC Insulated Conductors, Shield, PVC Jacket, 600V 30/15 Control Cable, PE/PVC Insulated Conductors, PVC Jacket, 1000V APPENDIX Terms & Conditions/Warranty Wire & Cable: Methods of Color Coding & Color Coding Charts Recommended Reel Handling Practices & Recycling/Reel Return Steel Reel Specifications Metric Size to AWG Size Copper Conductor Stranding Chart: Class A thru M Wire & Cable: Glossary of Terms

503 505 511 513 514 515 516 A B C D E G F

601 602 603 604 605

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

001


Return to Table of Contents

Bare Aluminum Code Name Finder Code Word Akron Alliance Alliance TP Alton Ames Ames TP Amherst Amherst TP Anaheim Anaheim TP Arbutus Arbutus TP Aster Aster TP Azusa Azusa TP Bersimis/AW Bittern Bittern/AW Bitterroot Bluebell Bluebell TP Bluebird Bluebird/AW Bluebonnet Bluejay Bluejay TP Bluejay/AW Bobolink Bobolink/AW Brahma Brahma/AW Brant Brant/AW Bunting Bunting/AW Butte Butte TP Cairo Camellia Canary Canary/AW Canna Canna TP Canton Cardinal Cardinal/AW

Size

Product Type

Catalog Page

30.58 246.9 246.9 48.69 77.47 77.47 195.7 195.7 155.4 155.4 795 795 2/0 2/0 123.3 123.3 1361 1272 1272 2750 1034 1034 2156 2156 3500 1113 1113 1113 1431 1431 203.2 203.2 397.5 397.5 1193 1193 312.8 312.8 465.4 1000 900 900 397.5 397.5 394.5 954 954

AAAC-6201 AAAC-6201 TP-AAAC-6201 AAAC-6201 AAAC-6201 TP-AAAC-6201 AAAC-6201 TP-AAAC-6201 AAAC-6201 TP-AAAC-6201 AAC TP-AAC AAC TP-AAC AAAC-6201 TP-AAAC-6201 ACSR/AW ACSR ACSR/AW AAC AAC TP-AAC ACSR ACSR/AW AAC ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR ACSR/AW ACSR ACSR/AW ACSR ACSR/AW AAAC-6201 TP-AAAC-6201 AAAC-6201 AAC ACSR ACSR/AW AAC TP-AAC AAAC-6201 ACSR ACSR/AW

404 404 405 404 404 405 404 405 404 405 403 405 403 405 404 405 402 401 402 403 403 405 401 402 403 401 405 402 401 402 401 402 401 402 401 402 404 405 404 403 401 402 403 405 404 401 402

Code Word Carnation Catbird/AW Cattail Chickadee Chickadee TP Chickadee/AW Chukar Chukar/AW Cochin Cochin/AW Cockscomb Cockscomb TP Columbine Condor Condor/AW Coot Coot/AW Coreopsis Cosmos Cosmos TP Cowslip Crane/AW Creeper TP Crow/AW Cuckoo Cuckoo/AW Curlew Curlew/AW Daffodil Dahlia Dahlia TP Daisy Daisy TP Darien Day Lily TP Dipper Dipper/AW Dorking Dorking/AW Dotterel Dotterel/AW Dove Dove TP Dove/AW Drake Drake TP Drake/AW

Size

Product Type

Catalog Page

1431 AAC 403 954 ACSR/AW 402 750 AAC 403 397.5 ACSR 401 397.5 TP-ACSR 405 397.5 ACSR/AW 402 1780 ACSR 401 1780 ACSR/AW 402 211.3 ACSR 401 211.3 ACSR/AW 402 900 AAC 403 900 TP-AAC 405 1352 AAC 403 795 ACSR 401 795 ACSR/AW 402 795 ACSR 401 795 ACSR/AW 402 1590 AAC 403 477 AAC 403 477 TP-AAC 405 2000 AAC 403 874.5 ACSR/AW 402 517 TP-AAC 405 715.5 ACSR/AW 402 795 ACSR 401 795 ACSR/AW 402 1034 ACSR 401 1034 ACSR/AW 402 350 AAC 403 556.5 AAC 403 556.5 TP-AAC 405 266.8 AAC 403 266.8 TP-AAC 405 559.5 AAAC-6201 404 596 TP-AAAC-6201 405 1352 ACSR 401 1352 ACSR/AW 402 190.8 ACSR 401 190.8 ACSR/AW 402 176.9 ACSR 401 176.9 ACSR/AW 402 556.5 ACSR 401 556.5 TP-ACSR 405 556.5 ACSR/AW 402 795 ACSR 401 795 TP-ACSR 405 795 ACSR/AW 402

Code Word Duck/AW Dunlin TP Eagle Eagle/AW Egret Egret/AW Elgin Falcon Falcon/AW Finch Finch/AW Flag Flamingo Flamingo TP Flamingo/AW Flicker Flicker TP Flicker/AW Flint Flycatcher TP Gannet Gannet/AW Gladiolus Gloxinia 12 Goldenrod Goldentuft Goose/AW Grackle Grackle/AW Greeley Grosbeak Grosbeak/AW Grouse Guinea Guinea/AW Gull/AW Hawk Hawk TP Hawk/AW Hawkweed Hawthorn Hen Hen/AW Heron/AW Heuchera Hyacinth Ibis

Size

Product Type

Catalog Page

605 ACSR/AW 402 715.5 TP-ACSR 405 556.5 ACSR 401 556.5 ACSR/AW 402 636 ACSR 401 636 ACSR/AW 402 652.4 AAAC-6201 404 1590 ACSR 401 1590 ACSR/AW 402 1113 ACSR 401 1113 ACSR/AW 402 700 AAC 403 666.6 ACSR 401 666.6 TP-ACSR 405 666.6 ACSR/AW 402 477 ACSR 401 477 TP-ACSR 405 477 ACSR/AW 402 740.8 AAAC-6201 404 516.8 TP-AAAC-6201 405 666.6 ACSR 401 666.6 ACSR/AW 402 1511 AAC 403 666.6 TP-AAC 405 954 AAC 403 450 AAC 403 636 ACSR/AW 402 1193 ACSR 401 1193 ACSR/AW 402 927.2 AAAC-6201 404 636 ACSR 401 636 ACSR/AW 402 80.0 ACSR 401 159.0 ACSR 401 159 ACSR/AW 402 666.6 ACSR/AW 402 477 ACSR 401 477 TP-ACSR 405 477 ACSR/AW 402 1000 AAC 403 1193 AAC 403 477 ACSR 401 477 ACSR/AW 402 500 ACSR/AW 402 650 AAC 403 500 AAC 403 397.5 ACSR 401

TP is Twisted Pair — Bare Aluminum

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

002


Return to Table of Contents

Bare Aluminum Code Name Finder Code Word Ibis TP Ibis/AW Iris Iris TP Jaeger TP Jessamine Joree Kingbird Kingbird TP Kingbird/AW Kinglet TP Kittiwake TP Kiwi Kiwi/AW Lapwing Lapwing/AW Lark Lark/AW Larkspur Laurel Leghorn Leghorn/AW Lilac Lily TP Linnet Linnet TP Linnet/AW Lupine Magnolia Mallard Mallard/AW Marigold Marigold TP Martin Martin/AW Meadowsweet Merlin Merlin TP Merlin/AW Minorca Minorca/AW Mistletoe Narcissus Nasturtium Nuthatch Nuthatch/AW Orchid

Size

Product Type

Catalog Page

397.5 397.5 2 2 228.2 1750 2513 636 636 636 556.5 596 2167 2167 1590 1590 397.5 397.5 1034 266.8 134.6 134.6 795 3 336.4 336.4 336.4 2500 954 795 795 1113 1114 1352 1352 600 336.4 336.4 336.4 110.8 110.8 556.5 1272 715.5 1511 1511 636

TP-ACSR ACSR/AW AAC TP-AAC TP-ACSR AAC ACSR ACSR TP-ACSR ACSR/AW TP-ACSR TP-ACSR ACSR ACSR/AW ACSR ACSR/AW ACSR ACSR/AW AAC AAC ACSR ACSR/AW AAC TP-AAC ACSR TP-ACSR ACSR/AW AAC AAC ACSR ACSR/AW AAC TP-AAC ACSR ACSR/AW AAC ACSR TP-ACSR ACSR/AW ACSR ACSR/AW AAC AAC AAC ACSR ACSR/AW AAC

405 402 403 405 405 403 401 401 405 402 405 405 401 402 401 402 401 402 403 403 401 402 403 405 401 405 402 403 403 401 402 403 405 401 402 403 401 405 402 401 402 403 403 403 401 402 403

Code Word Orchid TP Oriole Oriole/AW Ortolan Ortolan TP Ortolan/AW Osprey Osprey TP Osprey/AW Ostrich Ostrich/AW Oxlip Oxlip TP Pansy Pansy TP Parakeet Parakeet TP Parakeet/AW Parrot Parrot/AW Partridge Partridge TP Partridge/AW Peachbell Peacock Peacock/AW Pelican Pelican TP Pelican/AW Penguin Penguin TP Penguin/AW Peony Petrel Petrel/AW Petunia Pheasant Pheasant/AW Phlox Phlox TP Phoebe/AW Pigeon Pigeon TP Pigeon/AW Piper/AW Plover Plover/AW

Size

Product Type

Catalog Page

636 336.4 336.4 1034 1034 1034 556.5 556.5 556.5 300 300 4/0 4/0 1 1 556.5 556.5 556.5 1511 1511 266.8 266.8 266.8 6 605 605 477 477 477 4/0 4/0 4/0 300 101.8 101.8 750 1272 1272 3/0 3/0 300 3/0 3/0 3/0 300 1431 1431

TP-AAC ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR ACSR/AW AAC TP-AAC AAC TP-AAC ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR TP-ACSR ACSR/AW AAC ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR TP-ACSR ACSR/AW AAC ACSR ACSR/AW AAC ACSR ACSR/AW AAC TP-AAC ACSR/AW ACSR TP-ACSR ACSR/AW ACSR/AW ACSR ACSR/AW

405 401 402 401 405 402 401 405 402 401 402 403 405 403 405 401 405 402 401 402 401 405 402 403 401 402 401 405 402 401 405 402 403 401 402 403 401 402 403 405 402 401 405 402 402 401 402

Code Word Poppy Poppy TP PtarmiganTP Quail Quail TP Quail/AW Rail Rail/AW Raven Raven TP Raven/AW Redwing Redwing/AW Robin Robin TP Robin/AW Rook Rook TP Rook/AW Rose Ruddy Ruddy/AW Sagebrush Scoter Scoter/AW Siskin TP Skylark/AW Snapdragon Sneezewort Sparate Sparate/AW Sparrow Sparrow TP Sparrow/AW Squab Squab TP Squab/AW Starling Starling/AW Stilt Stilt/AW Surfbird TP Swallow TP Swallow/AW Swan Swan/AW Swanate

Size

Product Type

Catalog Page

1/0 1/0 397.5 2/0 2/0 2/0 954 954 1/0 1/0 1/0 715.5 715.5 1 1 1 636 636 636 4 900 900 2250 636 636 666.6 1272 900 250 2 2 2 2 2 605 605 605 715.5 715.5 715.5 715.5 874.5 3 3 4 4 4

AAC TP-AAC TP-ACSR ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR TP-ACSR ACSR/AW AAC ACSR ACSR/AW AAC ACSR ACSR/AW TP-ACSR ACSR/AW AAC AAC ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR ACSR/AW TP-ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR

403 405 405 401 405 402 401 402 401 405 402 401 402 401 405 402 401 405 402 403 401 402 403 401 402 405 402 403 403 401 402 401 405 402 401 405 402 401 402 401 402 405 405 402 401 402 401

TP is Twisted Pair — Bare Aluminum

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 002

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Bare Aluminum Code Name Finder Code Word

Size

Product Type

Catalog Page

Swanate/AW Swift Swift/AW Syringa Tanager/AW Tatler TP Teal Teal/AW Tern Tern TP

4 636 636 477 1034 477 605 605 795 795

ACSR/AW ACSR ACSR/AW AAC ACSR/AW TP-ACSR ACSR ACSR/AW ACSR TP-ACSR

402 401 402 403 402 405 401 402 401 405

Code Word Tern/AW Thrasher Thrasher/AW Trillium Tulip Tulip TP Turacos TP Turkey Twinstone TP Valerian

Size

Product Type

Catalog Page

795 2312 2312 3000 336.4 336.4 636 6 900 250

ACSR/AW ACSR ACSR/AW AAC AAC TP-AAC TP-ACSR ACSR TP-ACSR AAC

402 401 402 403 403 405 405 401 405 403

Code Word Verbena Violet TP Waxwing Waxwing TP Waxwing/AW Wood Duck Wood Duck/AW Zinnia

Size

Product Type

Catalog Page

700 715.5 266.8 266.8 266.8 605 605 500

AAC TP-AAC ACSR TP-ACSR ACSR/AW ACSR ACSR/AW AAC

403 405 401 405 402 401 402 403

TP is Twisted Pair — Bare Aluminum

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

002


Return to Table of Contents

345 Mil TRXLP 35kV URD Cable PowerGuard™ Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength PowerGuard™ TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water blocking agents, black encapsulating linear low-density polyethylene (LLDPE) jacket. Design Parameters Conductor: Class B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231. Stranded conductors are water-blocked with conductor filling compound. Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. Insulation: Extruded, unfilled Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-94-649—100% insulation level. Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. Metallic Shield: Solid bare copper wires helically applied and uniformly spaced. Water Block: Water-blocking agents applied over the insulation shield and around the neutral wires to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirements are 15 psig for 1 hour. Jacket: Black insulating sunlight resistant linear low-density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol. Insulation Temperature Rating Normal.............................. 90°C Emergency*.................... 130°C Short Circuit.................... 250°C *Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable. Specifications • ASTM B-231 • AEIC CS8 • ICEA S-94-649 • ICEA T-31-610 • ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable • UL 1072 Applications PowerGuard™ cables are intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried. Options • Copper Conductors • Black LLDPE jacket with no stripes • Multiplex cables

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2011, American Wire Group, Inc. Hallandale, Florida

312


Return to Table of Contents

345 Mil TRXLP 35kV URD Cable PowerGuard™ Item #

Conductor Nominal Minimum Minimum Size Diameter Insulation Insulation AWG (in) Diameter2 Diameter2 or kcmil1 (in) (in)

Neutral Size

345 mils NOMIMAL TRXLPE INSULATION — 100% INSULATION LEVEL UR1C1ALW1614DA35 1/0 0.362 1.045 1.145 Full UR1C1ALW1114DA35 1/0 0.362 1.045 1.145 2/3 UR1C1ALW0814DA35 1/0 0.362 1.045 1.145 1/2 UR1C1ALW0614DA35 1/0 0.362 1.045 1.145 1/3 UR1C2ALW2014DA35 2/0 0.408 1.090 1.190 Full UR1C2ALW1414DA35 2/0 0.408 1.090 1.190 2/3 UR1C2ALW1014DA35 2/0 0.408 1.090 1.190 1/2 UR1C2ALW0714DA35 2/0 0.408 1.090 1.190 1/3 UR1C3ALW1612DA35 3/0 0.458 1.140 1.240 Full UR1C3ALW1714DA35 3/0 0.458 1.140 1.240 2/3 UR1C3ALW1314DA35 3/0 0.458 1.140 1.240 1/2 UR1C3ALW0914DA35 3/0 0.458 1.140 1.240 1/3 UR1C4ALW2012DA35 4/0 0.515 1.195 1.295 Full UR1C4ALW2114DA35 4/0 0.515 1.195 1.295 2/3 UR1C4ALW1614DA35 4/0 0.515 1.195 1.295 1/2 UR1C4ALW1114DA35 4/0 0.515 1.195 1.295 1/3 UR1C4ALW0614DA35 4/0 0.515 1.195 1.295 1/6 UR1E5ALX1314DA35 250 0.561 1.250 1.350 1/3 UR1E5ALX1016DA35 250 0.561 1.250 1.350 1/6 UR1E5ALX0616DA35 250 0.561 1.250 1.350 1/12 UR1F5ALX1609DA35 350 0.661 1.355 1.455 Full UR1F5ALX2212DA35 350 0.661 1.355 1.455 2/3 UR1F5ALX1712DA35 350 0.661 1.355 1.455 1/2 UR1F5ALX1814DA35 350 0.661 1.355 1.455 1/3 UR1F5ALX0914DA35 350 0.661 1.355 1.455 1/6 UR1F5ALX0716DA35 350 0.661 1.355 1.455 1/12 UR1H0ALX2010DA35 500 0.790 1.480 1.580 2/3 UR1H0ALX2412DA35 500 0.790 1.480 1.580 1/2 UR1H0ALX1612DA35 500 0.790 1.480 1.580 1/3 UR1H0ALX1314DA35 500 0.790 1.480 1.580 1/6 UR1H0ALX1016DA35 500 0.790 1.480 1.580 1/12 UR1J5ALY2310DA35 750 0.968 1.670 1.770 1/2 UR1J5ALY2412DA35 750 0.968 1.670 1.770 1/3 UR1J5ALY1914DA35 750 0.968 1.670 1.770 1/6 UR1J5ALY1014DA35 750 0.968 1.670 1.770 1/12 UR1K0ALY3010DA35 1000 1.117 1.815 1.920 1/2 UR1K0ALY2010DA35 1000 1.117 1.815 1.920 1/3 UR1K0ALY1612DA35 1000 1.117 1.815 1.920 1/6 UR1K0ALY1314DA35 1000 1.117 1.815 1.920 1/12 UR1M5ALZ2510DA35 1250 1.250 2.045 2.155 1/3 UR1M5ALZ2012DA35 1250 1.250 2.045 2.155 1/6 UR1M5ALZ1614DA35 1250 1.250 2.045 2.155 1/12 UR1P0ALZ2409DA35 1500 1.370 2.120 2.205 1/3 UR1P0ALZ2412DA35 1500 1.370 2.120 2.205 1/6 UR1P0ALZ1914DA35 1500 1.370 2.120 2.205 1/12

Number of Wires

Size of Wires

16 11 8 6 20 14 10 7 16 17 13 9 20 21 16 11 6 13 10 6 16 22 17 18 9 7 20 24 16 13 10 23 24 19 10 30 20 16 13 25 20 16 24 24 19

14 14 14 14 14 14 14 14 12 14 14 14 12 14 14 14 14 14 16 16 9 12 12 14 14 16 10 12 12 14 16 10 12 14 14 10 10 12 14 10 12 14 9 12 14

Nominal Aluminum Jacket Conductor Diameter2 Wt/MFT (in) (lb) 1.41 1.41 1.41 1.41 1.45 1.45 1.45 1.45 1.56 1.50 1.50 1.50 1.60 1.58 1.58 1.58 1.58 1.62 1.60 1.60 1.90 1.81 1.81 1.77 1.77 1.74 1.98 1.95 1.95 1.92 1.89 2.20 2.16 2.14 2.14 2.36 2.36 2.32 2.27 2.61 2.54 2.49 2.69 2.62 2.58

99 99 99 99 125 125 125 125 157 157 157 157 198 198 198 198 198 234 234 234 328 328 328 328 328 328 469 469 469 469 469 703 703 703 703 937 937 937 937 1173 1173 1173 1408 1408 1408

Copper Neutral Wt/MFT (lb)

Total Weight Wt/MFT (lb)

Ampacity Direct Buried Flat4

Ampacity Direct Buried Trefoil3

209 144 104 78 266 187 133 93 332 222 170 118 415 274 209 144 78 170 84 51 667 458 354 235 117 59 662 498 332 170 84 761 498 248 133 993 660 332 173 827 415 209 1002 497 248

914 841 812 802 982 912 865 852 1190 1044 951 944 1330 1171 1126 1074 1020 1160 1069 1033 1993 1695 1603 1457 1358 1256 2181 1983 1854 1669 1629 2727 2434 2163 2076 3311 3015 2658 2455 3755 3225 2984 4036 3474 3193

221 221 221 221 251 251 252 252 286 287 287 287 324 326 326 327 327 359 360 360 420 431 433 436 436 437 523 526 531 534 531 631 640 651 661 724 726 752 768 790 832 857 868 910 940

242 244 245 246 273 276 278 279 307 311 314 317 343 349 352 357 362 388 397 401 416 428 434 445 460 469 496 500 516 546 575 572 581 626 686 639 650 700 767 695 737 821 702 722 813

1) Diameters are based on ASTM Class B Compressed diameters. Sizes 1250 kcmil and 1500 kcmil are based on ASTM Class A Compressed diameters. 2) Extruded layer thicknesses, insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for Concentric Neutral Cables Rated 5-46kV and also meet the requirements of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances. 3) Ampacity based on earth thermal resistivity of 90°C-cm/watt, 90°C conductor temperature, 20°C earth ambient temperature, 75% load factor and 36" depth of burial. Values are based on one three-phase circuit, one conductor per phase, with neutral wires bonded at each end. 4) Cables buried in flat adjacent configuration with 7.5" spacing between conductors.

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 312

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright © 2011, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

TowerGuard CCATM Power Cable 2000V (UL) RHH OR RHW-2 Copper Clad Aluminum Conductor/90°C Wet or Dry For Cable Tray Use — Sunlight Resistant — For Direct Burial Patent Pending

Applications This cable is intended for fixed installation in wind turbine towers. Good resistance to temperatures, oils, ozone and fire. Construction Nominal voltage: RHH/RHW-2 2000V UL Conductor: The conductor shall be a bunched or rope-lay-stranded wire composed of 15% Copper Clad Aluminum (CCA) wires specified in ASTM B-566 and stranded in accordance with ASTM B-172 as applicable. Separator: A suitable tape separator between the conductor and insulation. Insulation: Ethylene-propylene rubber (EPR) type EP, meeting UL and ICEA requirements for 90ºC. Jacket: A heavy duty, thermosetting CPE in accordance with ICEA S-95-658 NEMA WC70 Jacket Color: Black Print Legend:TOWERGUARD CCA™ (SIZE) Cu-Clad AL Type RHH or RHW-2 2000V Sun Res PATENT PENDING (SEQUENTIAL FOOTAGE MARKER)

Item #

Conductor Stranding Size AWG/kcmil

CCA4/0-01TWRGRD 4/0 CCA250-01TWRGRD 250 CCA350-01TWRGRD 350 CCA500-01TWRGRD 500 CCA600-01TWRGRD 600 CCA750-01TWRGRD 750 CCA800-01TWRGRD 800 CCA900-01TWRGRD 900 CCA1000-01TWRGRD 1000

329 399 551 779 925 1184 1258 1406 1554

Specifications • ICEA S-95-658 / NEMA WC70 • UL Standard 44 • ASTM B 556 • ASTM B 172 Product Features • Flexible cable design — TowerGuard CCA can bend to a radius of 6 times the O.D. without impairing the insulation. • 90°C (dry) 90°C (wet) • Ozone, sunlight, oil, grease, weather, water, chemical and abrasion resistant jacket • Surface printed for easy identification • 40% lighter weight and easier to install than copper cables with equal ampacity • 35% less expensive than copper cables with equal ampacity • No scrap value (theft deterrent) • Sequential footage markers • Patent pending

Nominal Conductor Diameter (in)

Nominal Insulation Thickness (mil)

Nominal Jacket Thickness (in)

Maximum Cable Diameter (mil)

Copper Weight /MFT (lb)

Aluminum Weight /MFT (lb)

Net Cable Weight /MFT (lb)

Ampacity* 90°C Free Air

Ampacity** 90°C Duct

0.540 0.602 0.707 0.841 0.919 1.040 1.072 1.133 1.191

65 75 75 75 75 90 90 90 90

45 65 65 65 65 65 65 65 65

0.760 0.882 0.987 1.121 1.199 1.350 1.382 1.443 1.501

96 116 161 227 270 345 367 410 453

165 200 277 391 464 595 632 706 780

458 590 756 979 1301 1462 1521 1733 1850

356 400 500 636 708 780 832 954 1060

235 260 315 390 435 480 521 558 621

*Ampacity is calculated based on a single conductor in free air with a 90°C conductor temperature and 30°C ambient, per 2005 NEC, Table 310-17 **Ampacity is calculated based on 3 conductors in a duct with a 90°C conductor temperature and 30°C ambient, per 2005 NEC, Table 310-17

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

201


Return to Table of Contents

TowerGuard XLP Power Cable Type RHH or RHW-2, VW-1 Aluminum Conductor, 2kV Applications • For use from the lower control box at the base of the wind power tower and out to the stepup transformer through conduit • General purpose building wire for use in air and approved raceways • Industrial environments where superior insulation toughness and chemical resistance is required • Maximum operating temperature not to exceed 90°C in wet or dry locations Product Construction Conductor: • 8 AWG thru 1000 kcmil compacted aluminum ACM (AA-8000 Series) Insulation: • Flame-retardant Cross-Linked Polyethylene (XLPE) — Black Print: • TOWERGUARD XLP AWG/KCMIL TYPE RHH/RHW-2 SR CT (UL) 2000V (MM/YYYY) SEQUENTIAL FOOTAGE MARK • Sizes smaller than 1/0 AWG do not include the “CT” marking

Item #

TGXL-08 TGXL-06 TGXL-04 TGXL-02 TGXL-01 TGXL-1/0 TGXL-2/0 TGXL-3/0 TGXL-4/0 TGXL-250 TGXL-350 TGXL-500 TGXL-600 TGXL-750 TGXL-1000

Compliances • National Electric Code (NEC) • UL 44 Stranded for rubber-insulated wires and cables • “CT” for 1/0 AWG and larger in accordance with NEC • ICEA S-95-685/NEMA WC70 • UL listed as Type RHH/RHW-2 • OSHA acceptable Features • Rated at 90°C wet or dry • UV resistant — black is marked SR • Excellent electrical, thermal and physical properties • Excellent resistance to moisture • Excellent resistance to crush, compression cuts and heat deformation Packaging • All produced or cut-to-order material will be shipped on non-returnable wooden reels unless specifically requested

Conductor Size AWG/kcmil

No. of Wires1

Conductor Diameter (in)

Insulation Thickness (mil)

Cable Diameter (in)

Aluminum Weight /MFT (lb)

Net Weight /MFT (lb)

Ampacity 90°C

8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500 600 750 1000

7 7 7 7 18 18 18 18 18 35 35 35 58 58 58

0.134 0.169 0.213 0.268 0.299 0.336 0.376 0.423 0.475 0.520 0.616 0.736 0.813 0.908 1.060

70 70 70 70 90 90 90 90 90 105 105 105 120 120 120

0.285 0.320 0.360 0.420 0.495 0.530 0.580 0.615 0.665 0.745 0.840 0.960 1.075 1.175 1.325

16 25 39 62 79 99 125 158 199 235 329 471 565 706 941

38 51 72 100 134 160 192 229 281 336 449 605 736 901 1168

45 60 75 100 115 135 150 175 205 230 280 350 385 435 500

Dimensions and weights are nominal; subject to industry tolerances. 1Minimum number of wires utilized for compact-strand constructions.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

202


Return to Table of Contents

Type DLO Diesel Locomotive Cable 600/2000V 90°C Applications This cable is for wiring down tower applications and may be used on electrically driven, earth moving equipment, as power supply to A.C. welding equipment, as water heater leads, and in motor and power lead applications. May be installed in wet or dry areas, conduit, ducts, trays or troughs. Construction • Conductor is extra flexible tinned, stranded copper with a separator layer. • EPR insulation. • Jacket is CPE (Hypalon jacket available upon request). Standards • Meets flame test requirements of MSHA and passes ICEA cold bend test at -40°C. • Meets AAR specifications. • UL listed as RHH-RHW-2. • Rated for CT use, 1/0 and larger. Notes • Ampacity based on single conductor in free air, 90°C conductor temperature, 40°C ambient per ICEAS-75-381. • Sequential footage marks. • Shipping tolerance +/- 10%

Item #

Area Circular (mil)

Size AWG

Number of Strands in Conductor

Insulation Thickness (in)

Jacket Thickness (mil)

Overall Diameter (in)

Net Weight /MFT (lb)

Ampacity 1/C Free Air 90°C

DL-600/2-1 DL-600/2-2 DL-600/2-3 DL-600/2-4 DL-600/2-5 DL-600/2-6 DL-600/2-7 DL-600/2-8 DL-600/2-9 DL-600/2-10 DL-600/2-11 DL-600/2-12 DL-600/2-13 DL-600/2-14 DL-600/2-15 DL-600/2-16 DL-600/2-17 DL-600/2-18 DL-600/2-19 DL-600/2-20 DL-600/2-21 DL-600/2-22

3831 6088 10910 14950 24640 36760 42420 60600 90900 111100 131300 181800 222200 262600 313100 373700 444400 535300 646400 777700 929200 1111000

14 12 10 8 6 5 4 2 1 1/0 2/0 3/0 4/0 262.6 313.1 373.7 444.4 535.3 646.4 777.7 929.2 1111.0

19 19 27 37 61 91 105 150 225 275 325 450 550 650 775 925 1100 1325 1591 1924 2299 2745

.045 .045 .045 .060 .060 .060 .060 .060 .080 .080 .080 .080 .080 .090 .090 .090 .090 .110 .110 .110 .110 .110

30 30 30 30 30 30 30 30 45 45 45 45 45 65 65 65 65 65 65 65 65 65

.24 .25 .29 .33 .40 .43 .45 .50 .64 .69 .73 .80 .86 .97 1.01 1.11 1.18 1.29 1.38 1.47 1.58 1.74

34 45 68 82 125 175 195 265 425 500 570 780 890 1100 1280 1500 1760 2110 2410 2930 3450 4130

32 36 55 83 109 127 145 192 223 258 298 345 400 458 514 574 642 725 815 910 1025 1143

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

709


Return to Table of Contents

SunGuard 1000 Power Cable 1kV Applications Single conductor, sunlight-resistant, photovoltaic wire rated 90°C wet or dry, 1000V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70. • Rated 90°C wet and dry • Deformation-resistant at high temperatures • Excellent moisture resistance, exceeds UL 44 • Stable electrical properties over a broad temperature range • Excellent resistance to crush and compression cuts • Resistant to most oils and chemicals • UV/sunlight-resistant • Meets cold bend test at -25°C Construction • Conductor is tinned coated compressed copper 18 AWG thru 2 AWG: Class C stranding per ASTM B33 and B8 1 AWG thru 4/0 AWG: Class B stranding per ASTM B33 and B8 • Insulation is flame-retardant Cross-Linked Polyethylene (XLPE) – Black

Item #

SUN-18 SUN-16 SUN-14 SUN-12 SUN-10 SUN-8 SUN-6 SUN-4 SUN-2 SUN-1 SUN-1/0 SUN-2/0 SUN-3/0 SUN-4/0

Specifications • UL 4703 Type PV • National Electrical Code (NEC) • ICEA S-95-658/NEMA WC70 • UL 44 Type RHH/RHW-2 • Meets requirements of UL 854 Type USE for 600V • UL 1581 VW-1 • For sizes 1/0 and larger: IEEE 383, IEEE 1202/CSA FT-4 • EPA 40 CFR, Part 261 for leachable lead content per TCLP • OSHA Acceptable Options • Bare copper conductor • Other stranding options are available upon request • Colors available on request

Conductor Size AWG

Conductor Stranding

Nominal Conductor O.D. (in)

Nominal Conductor O.D. (mm)

Nominal Insulation (in)

Nominal Insulation (mm)

Nominal Cable O.D. (in)

Nominal Cable O.D. (mm)

Copper Weight /MFT (lb)

Nominal Weight /MFT (lb)

18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0

19 19 19 19 19 19 19 19 19 19 19 19 19 19

0.045 0.056 0.07 0.088 0.112 0.143 0.184 0.234 0.296 0.323 0.37 0.41 0.46 0.52

1.14 1.42 1.78 2.23 2.84 3.63 4.67 5.94 7.52 8.2 9.4 10.41 11.68 13.21

0.075 0.075 0.075 0.075 0.075 0.085 0.085 0.085 0.085 0.105 0.105 0.105 0.105 0.105

1.9 1.9 1.9 1.9 1.9 2.16 2.16 2.16 2.16 2.67 2.67 2.67 2.67 2.67

0.204 0.215 0.229 0.248 0.298 0.325 0.39 0.445 0.5 0.6 0.655 0.71 0.76 0.82

5.18 5.46 5.82 6.3 7.57 8.25 9.9 11.3 12.7 15.24 16.64 18.03 19.3 20.83

5 8 13 20 32 50 81 129 205 258 326 411 518 653

16 21 32 42 57 87 123 181 266 350 429 527 647 796

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

203


Return to Table of Contents

Bare Copper Applications Used for overhead electrical distribution lines, grounding electrical substations, electrical test equipment and any other electrical system. Suitable for numerous other applications. Specifications ASTM Specifications, latest issue, as follows: Solid • ASTM B-3 Soft Drawn Temper • ASTM B-33 Tinned, Soft or Annealed Copper Wire Stranded • ASTM B-8 Concentric Lay, All Tempers Tinned • ASTM B-33 Tinned, Soft or Annealed Copper Wire Notes Ampacities (Amps per Conductor) are based on a 30°C ambient temperature, single conductor in air, per NEC.

Item #

SCC-01 SCC-02 SCC-03 SCC-04 SCC-05 SCC-06 SCC-07 STC-01 STC-02 STC-03 STC-04 STC-05 STC-06 STC-07 STC-08 STC-09 STC-06 STC-07 STC-08 STC-09 STC-10 STC-11 STC-12 STC-13 STC-14 STC-15 STC-16 STC-17

Size AWG or KCMIL

Number of Strands

Overall Diameter (in)

Weight /MFT (lb)

Amps per Conductor

Breaking Strength – Soft (lb)

Breaking Strength – Medium (lb)

Breaking Strength – Hard (lb)

14 12 10 8 6 4 2 8 6 4 2 1 1/0 2/0 3/0 4/0 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

Solid Solid Solid Solid Solid Solid Solid 7 7 7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 61 61 61

0.064 0.081 0.102 0.129 0.162 0.204 0.258 0.146 0.184 0.232 0.292 0.332 0.373 0.419 0.470 0.528 0.373 0.419 0.470 0.528 0.575 0.630 0.681 0.728 0.813 0.893 0.998 1.152

12.43 19.77 31.43 49.98 79.46 126.40 200.90 51.0 81.1 128.9 204.9 258.4 325.8 410.9 518.1 653.3 325.8 410.9 518.1 653.3 771.9 926.3 1081.0 1235.0 1544.0 1853.0 2316.0 3088.0

30 40 55 70 100 130 175 70 100 130 174 205 235 275 320 370 235 275 320 370 410 460 510 555 630 710 810 965

124 197 314 479 762 1213 1928 525 832 1320 2110 2660 3350 4230 5330 6453 3350 4230 5330 6453 7940 9520 11100 12210 15240 19000 22890 30500

189 297 467 734 1010 1584 2450 610 955 1500 2360 3040 3800 4770 5970 7473 3800 4770 5970 7473 8950 10700 12500 14140 17540 21400 26520 35000

214 337 529 826 1280 1970 3002 750 1200 1938 3000 3900 4900 6690 7700 9612 4900 6690 7700 9612 11600 13800 16100 183 22450 27500 34100 45000

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

101


Return to Table of Contents

Tinned Copper Applications Used for overhead electrical distribution lines, grounding electrical substations, electrical test equipment and any other electrical system. Suitable for numerous other applications. Specifications ASTM Specifications, latest issue, as follows: Solid • ASTM B-3 Soft Drawn Temper • ASTM B-33 Tinned, Soft or Annealed Copper Wire Stranded • ASTM B-3 Soft Drawn Temper • ASTM B-8 Concentric Lay, All Tempers Tinned • ASTM B-33 Tinned, Soft or Annealed Copper Wire Notes Ampacities (Amps per Cond.) are based on a 30°C ambient temperature, single conductor in air, per NEC.

Item #

SCC-T-01 SCC-T-02 SCC-T-03 SCC-T-04 SCC-T-05 SCC-T-06 SCC-T-07 STCC-T-01 STCC-T-02 STCC-T-03 STCC-T-04 STCC-T-05 STCC-T-06 STCC-T-07 STCC-T-08 STCC-T-09 STCC-T-06 STCC-T-07 STCC-T-08 STCC-T-09 STCC-T-10 STCC-T-11 STCC-T-12 STCC-T-13 STCC-T-14 STCC-T-15 STCC-T-16 STCC-T-17

Size AWG or KCMIL

Number of Strands

Overall Diameter (in)

Weight /MFT (lb)

Amps per Conductor

Breaking Strength – Soft (lb)

Breaking Strength – Medium (lb)

Breaking Strength – Hard (lb)

14 12 10 8 6 4 2 8 6 4 2 1 1/0 2/0 3/0 4/0 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

Solid Solid Solid Solid Solid Solid Solid 7 7 7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 61 61 61

0.064 0.081 0.102 0.129 0.162 0.204 0.258 0.146 0.184 0.232 0.292 0.332 0.373 0.419 0.470 0.528 0.373 0.419 0.470 0.528 0.575 0.630 0.681 0.728 0.813 0.893 0.998 1.152

12.43 19.77 31.43 49.98 79.46 126.40 200.90 51.0 81.1 128.9 204.9 258.4 325.8 410.9 518.1 653.3 325.8 410.9 518.1 653.3 771.9 926.3 1081.0 1235.0 1544.0 1853.0 2316.0 3088.0

30 40 55 70 100 130 175 70 100 130 174 205 235 275 320 370 235 275 320 370 410 460 510 555 630 710 810 965

124 197 314 479 762 1213 1928 525 832 1320 2110 2660 3350 4230 5330 6453 3350 4230 5330 6453 7940 9520 11100 12210 15240 19000 22890 30500

189 297 467 734 1010 1584 2450 610 955 1500 2360 3040 3800 4770 5970 7473 3800 4770 5970 7473 8950 10700 12500 14140 17540 21400 26520 35000

214 337 529 826 1280 1970 3002 750 1200 1938 3000 3900 4900 6690 7700 9612 4900 6690 7700 9612 11600 13800 16100 18330 22450 27500 34100 45000

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

102


Return to Table of Contents

Copper-Clad Steel Wire Applications High Strength (HS) and Extra High Strength (EHS) copper-clad steel wire and strand combines the electrical characteristics of copper with the mechanical properties of high strength and extra high strength steel. This combination, often used as overhead ground wire and messenger wire, can resist mechanical damage during installation, as well as electrical damage during a fault condition. The heat process that bonds the thick copper to the exterior of the steel core ensures that the copper will not flake, crack, or peel when the wire is twisted, installed, or buried. Overhead Ground Wire The reliable, uninterrupted transmission of electrical power is vital to the electric utility industry. Power lines carrying large blocks of power must be permanently protected from lightening. Copperclad HS and EHS wire and strand provide a means of obtaining this protection. The combination of conductivity, corrosion resistance and high strength are the foundation of this protection. Guy Wire Copper-clad HS and EHS strand can be used as a corrosion resistant guying material for distribution and transmission lines. The thick cladding of copper on each wire protects the high strength steel core from rusting and subsequent loss of strength. Messenger Wire Copper-clad HS and EHS wire and strand can be used as a messenger wire. Copper-clad wire and strand provides the overhead support and electrification of a catenary system. High strength and conductivity make copper-clad wire and strand a good choice for this application. Diameter Comparison for Copper Equivalent Fusing Current for Grounding Applications Copper-Clad Steel 40% DSA AWG (Equiv.) Size Diameter (in) Size Diameter (in) #6 sol #4 sol 7 #10 40% DSA 7 #8 40% DSA 7 #7 40% DSA 7 #6 40% DSA 19 #9 40% DSA 19 #8 40% DSA 19 #7 40% DSA 19 #6 40% DSA 19 #5 40% DSA

0.162 0.204 0.306 0.385 0.433 0.486 0.572 0.642 0.71 0.81 0.91

#6 sol #4 sol #2 7W 1/0 7W 2/0 7W 3/0 7W 4/0 7W 250 12W 300 19W 400 19W 500 19W

0.162 0.204 0.292 0.325 0.365 0.41 0.46 0.6 0.628 0.726 0.811

Note: The copper-clad steel cables shown in this table are not equal ampacity to copper.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2011, American Wire Group, Inc. Hallandale, Florida

104


Return to Table of Contents

Copper-Clad Steel Wire Item #

End Individual Individual Count Cond. Cond. Size Size AWG (in)

7-Wire Strand 7#4 7 7#5 7 7#6 7 7#7 7 7#8 7 7#9 7 7#10 7 19-Wire Strand 19#5 19 19#6 19 19#7 19 19#8 19 19#9 19 Solid Wire #2 1 #4 1 #6 1

Stranded Stranded Cond. Cond. Nominal Nominal Diameter Diameter (in) (mm)

Minimum Breaking Load 40% Conductivity 30% Conductivity (lb) (kN) (lb) (kN)

Weight (density is Cross average of 30% & 40%) Section /MFT /km (Circular (mm2) (lb) (kg) mils)

DC Resistance /MFT @ 68° 40% 30% Conductivity Conductivity (ohm) (ohm)

4 5 6 7 8 9 10

0.2043 0.1819 0.1620 0.1443 0.1285 0.1144 0.1019

0.613 0.546 0.486 0.433 0.385 0.343 0.306

15.57 13.87 12.34 11.00 9.78 8.71 7.77

8,261 6,549 5,194 4,121 3,268 2,590 2,055

36.75 29.13 23.11 18.33 14.54 11.52 9.14

9,294 7,367 5,843 4,636 3,677 2,914 2,312

41.34 32.77 25.99 20.62 16.35 12.96 10.28

814.94 646.29 512.54 406.47 322.35 255.64 202.73

1212.68 961.72 762.69 604.85 479.68 380.41 301.68

292,169 231,613 183,708 145,757 115,586 91,612 72,685

190.34 150.89 119.68 94.96 75.30 59.68 47.35

0.090552 0.114182 0.143978 0.181550 0.228927 0.288667 0.363996

0.120736 0.152242 0.191971 0.242067 0.305236 0.384889 0.485328

5 6 7 8 9

0.1819 0.1620 0.1443 0.1285 0.1144

0.9097 0.8101 0.7214 0.6425 0.5721

23.11 20.58 18.32 16.32 14.53

17,775 14,099 11,186 8,871 7,031

79.07 62.71 49.76 39.46 31.27

19,997 15,861 12,584 9,979 7,910

88.95 70.55 55.98 44.39 35.18

1754.22 1391.18 1103.27 874.95 693.88

2610.38 2070.16 1641.74 1301.98 1032.53

628,665 498,636 395,627 313,733 248,660

419.14 332.45 263.77 209.17 165.79

0.042067 0.053045 0.066887 0.084341 0.106351

0.056089 0.070726 0.089183 0.112455 0.141801

2 4 6

0.2576 0.2043 0.1620

0.2576 0.2043 0.1620

6.54 5.19 4.12

2,085 1,311 825

9.27 5.83 3.67

2,345 1,475 928

10.43 6.56 4.13

185.11 116.42 73.22

275.45 173.24 108.96

66,365 41,628 26,250

33.63 21.09 13.30

0.398653 0.633862 1.007847

0.531537 0.845149 1.343796

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 104

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright © 2011, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Copper-Clad Steel Wire APPROXIMATE SHORT-TIME FUSING CURRENTS Duration of Current in Cycles or Seconds Conductor Size AWG

3 cycles (.05 sec)

6 cycles (.10 sec)

9 cycles (.15 sec)

30 cycles (.5 sec)

60 cycles (1.0 sec)

120 cycles (2.0 sec)

Current in Amperes 40% Conductivity 7-Wire Strand 7 No. 4 7 No. 5 7 No. 6 7 No. 7 7 No. 8 7 No. 9 7 No. 10 19-Wire Strand 19 No. 5 19 No. 6 19 No. 7 19 No. 8 19 No. 9 Solid Wire No. 2 Wire No. 4 Wire No. 6 Wire

7-Wire Strand 7 No. 4 7 No. 5 7 No. 6 7 No. 7 7 No. 8 7 No. 9 7 No. 10 19-Wire Strand 19 No. 5 19 No. 6 19 No. 7 19 No. 8 19 No. 9 Solid Wire No. 2 Wire No. 4 Wire No. 6 Wire

154,000 122,000 97,000 77,000 61,000 48,000 38,000

109,000 86,000 68,000 54,000 43,000 34,000 27,000

89,000 70,000 56,000 44,000 35,000 28,000 22,000

49,000 38,000 31,000 24,200 19,000 15,000 12,000

34,000 27,000 22,000 17,000 14,000 11,000 8,500

24,000 19,000 15,000 12,000 10,000 7,600 6,000

330,000 262,000 208,000 165,000 131,000

234,000 185,000 147,000 117,000 92,000

191,000 151,000 120,000 95,000 74,000

104,000 83,000 66,000 52,000 41,000

74,000 59,000 46,000 37,000 29,000

52,000 41,000 33,000 26,000 21,000

35,000 22,000 14,000

25,000 16,000 9,800

11,000 6,900 4,400

7,800 4,900 3,100

5,500 3,500 2,200

137,000 108,000 86,000 68,000 54,000 43,000 34,000

97,000 77,000 61,000 48,000 38,000 30,000 24,000

79,000 63,000 50,000 39,000 31,000 25,000 20,000

43,000 34,000 27,000 22,000 17,000 14,000 11.000

31,000 24,000 19,000 15,000 12,000 9,600 7,600

22,000 17,000 14,000 11,000 9,000 6,800 5,400

294,000 233,000 185,000 147,000 116,000

208,000 165,000 131,000 104,000 82,000

170,000 135,000 107,000 85,000 67,000

93,000 74,000 58,000 46,000 37,000

66,000 52,000 41,000 33,000 26,000

47,000 37,000 29,000 23,000 18,000

31,000 20,000 12,000

22,000 14,000 9,000

18,000 11,000 7,100

9,800 6,200 3,900

6,900 4,400 2,700

4,900 3,100 1,900

20,000 13,000 8,000 Current in Amperes 30% Conductivity

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

104


Return to Table of Contents

Alumo-Clad Steel Wire Application Overhead ground wire, shield wire protecting transmission lines against lightning damage. Construction Alumo-clad steel wire and strand is used by power utilities as well as formed wire and optical ground wire manufacturers. alumo-clad steel wire outlasts other options by as much as 200% in corrosive environments, significantly lowering maintenance and replacement costs. When compared to solid aluminum wire, alumo-clad steel wire offers tremendous savings. Alumo-clad steel wire overhead ground wire has excellent corrosion resistance. Its strength and conductivity remain unchanged in any atmosphere where aluminum is satisfactory, especially those known to be corrosive from industrial or atmospheric conditions. This assurance against corrosion is obtained through the application of a thick covering of pure aluminum which provides a substantial barrier of protective metal. The minimum cladding thickness of Alumo-clad steel wire is 10% of the radius of the wire. the cladding has a continuous, strong metallic bond to the steel core that will not crack or flake. Alumo-clad steel wire also provides strength greater than or equal to other overhead ground wires. For commonly used wire sizes, the tensile strength of the individual wire can approach 200,000 pounds per square inch. When used in a strand for overhead ground wire, this high strength permits greater span lengths, less sag and heavier loads under storm loading conditions. Directly related to strength and sag performance is the lighter weight of alumo-clad steel wire. Due to its thick cladding of aluminum, alumo-clad steel wire is 15% lighter that a steel strand of equivalent size. This lighter weight, combined with high strength, permits alumo-clad steel wire to be installed to the same sags as steel with correspondingly lower tensions and tower stresses on the towers or supporting structures.

Item #

ALUM-01 ALUM-02 ALUM-03 ALUM-04 ALUM-05 ALUM-06 ALUM-07 ALUM-08 ALUM-09 ALUM-10 ALUM-11 ALUM-12 ALUM-13 ALUM-14 ALUM-15 ALUM-16 ALUM-17 ALUM-18 ALUM-19 ALUM-20 ALUM-21 ALUM-22

No. and Size of Wire

Nominal Diameter (in)

Nominal Diameter (mm)

Breaking Load (lb)

Breaking Load (kg)

Weight /MFT (lb)

Weight /km (kg)

37 #5 37 #6 37 #7 37 #8 37 #9 37 #10 19 #5 19 #6 19 #7 19 #8 19 #9 19 #10 7 #5 7 #6 7 #7 7 #8 7 #9 7 #10 7 #11 7 #12 3 #5 3 #6

1.270 1.130 1.010 .899 .801 .713 .910 .810 .721 .642 .572 .509 .546 .486 .433 .385 .343 .306 .272 .242 .392 .349

32.30 28.80 25.70 22.90 20.30 17.90 23.10 20.60 18.30 16.30 14.50 12.90 13.90 12.40 11.00 9.78 8.71 7.76 6.91 6.16 9.96 8.87

142800 120200 100700 84200 66770 52950 73350 61700 51730 43240 34290 27190 27030 22730 19060 15930 12630 10020 7945 6301 12230 10280

647900 54500 45690 38190 30290 24020 33270 27990 23460 19610 15550 15550 12260 10310 8645 7226 5729 4545 3604 2858 5547 4663

2802 2222 1762 1398 1108 879 1430 1134 899.5 713.5 565.8 448.7 524.9 416.3 330.0 261.8 207.6 164.7 130.6 103.6 224.5 178.1

4170 3307 2623 2080 1649 1308 2129 1688 1339 1062 842.0 667.7 781.1 619.5 491.1 389.6 308.9 245.1 194.4 154.2 334.1 265.0

Resistance Resistance /MFT /km @ 68°F @ 20°F (ohm) (ohm) .04247 .05356 .06754 .08516 .1074 .1354 .08224 .1037 .1308 .1649 .2079 .2622 .2264 .2803 .3535 .4458 .5621 .7088 .8938 1.127 .5177 .6528

.1394 .1757 .2216 .2794 .3523 .4443 .2698 .3402 .4290 .5409 .6821 .8601 .7426 .9198 1.160 1.463 1.844 2.325 2.932 3.697 1.699 2.142

Area (in2)

Area (mm2)

.96152 .76264 .60509 .47984 .38032 .30174 .49438 .39163 .31073 .24641 .19530 .15495 .18193 .14435 .11448 .09077 .07198 .05708 .04527 .03590 .07796 .06185

620.60 492.20 390.30 309.50 245.50 194.70 318.70 252.70 200.40 158.90 126.10 99.96 117.40 93.10 73.87 58.56 46.44 36.83 29.21 23.16 50.32 39.90

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

105


Return to Table of Contents

Alumo-Clad Steel Wire Item #

ALUM-23 ALUM-24 ALUM-25 ALUM-26 ALUM-27 ALUM-28 ALUM-29 ALUM-30 ALUM-31 ALUM-32 ALUM-33 ALUM-34 ALUM-35

No. and Size of Wire

Nominal Diameter (in)

Nominal Diameter (mm)

Breaking Load (lb)

Breaking Load (kg)

Weight /MFT (lb)

Weight /km (kg)

3 #7 3 #8 3 #9 3 #10 #4 #5 #6 #7 #8 #9 #10 #11 #12

.311 .277 .247 .220 .2043 .1819 .1620 .1443 .1285 .1144 .1019 .0907 .0808

7.90 7.03 6.26 5.58 5.19 4.62 4.12 3.67 3.26 2.91 2.59 2.30 2.05

8621 72060 5715 4532 5081 4290 3608 3025 2529 2005 1590 1261 1000

3910 3269 2592 2056 2305 1946 1637 1372 1147 909 721 572 454

141.2 112.0 888.1 704.3 936.3 742.5 588.8 466.9 370.3 293.7 232.9 184.7 146.5

201.1 166.7 132.2 104.8 139.3 110.5 87.62 69.48 55.11 43.71 34.66 27.49 21.80

Resistance Resistance /MFT /km @ 68°F @ 20°F (ohm) (ohm) .8232 2.701 1.038 3.406 1.309 4.294 1.651 5.415 1.222 4.009 1.541 5.056 1.943 6.375 2.450 8.038 3.089 10.13 3.986 12.78 4.912 16.12 6.194 20.32 7.811 25.63

Area (in2)

Area (mm2)

.04905 .03890 .03085 .02446 .03278 .02599 .02062 .01635 .01297 .01028 .00816 .00647 .00513

31.65 25.10 19.90 15.78 21.15 16.77 13.30 10.55 8.368 6.632 5.261 4.172 3.309

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 105

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Type M Alumo-Clad Steel Wire Guy Strand Application Power lines, telephone lines, railway signals, communication lines, towers, masts. Construction Type M alumo-clad guy strand is an economical, corrosion resistant buying material for use on overhead line structures. The thick cladding of aluminum on each wire protects the high-strength steel core from rusting and subsequent loss of strength. Costly maintenance is eliminated and the original safety factor of the guy is maintained throughout the life of the line. The alumo-clad steel wire used to make Type M guy strand is unique in that the aluminum cladding thickness is guaranteed to be no less than 10% of the wire radius. Thus, a thick corrosion barrier that is pure aluminum not zinc or and iron-aluminum alloy protects the steel core. Another important feature of any coated or clad wire is the bond between the coating material and the base metal. In the case of alumo-clad steel wire, the aluminum cladding and steel core are joined by a continuous ductile weld. This assures against cracking or separating of the protective aluminum form the steel core. Type M alumo-clad steel wire guy strand is easily handled and installed. It weighs less than any of the other high-strength guying materials.

Item #

AGM-1 AGM-2 AGM-3 AGM-4 AGM-5 AGM-6 AGM-7 AGM-8 AGM-9 AGM-10 AGM-11 AGM-12 AGM-13 AGM-14 AGM-15 AGM-16 AGM-17 AGM-18 AGM-19

Designation

Construction Nos. (in)

AWG (Equiv.)

Stranded Diameter (in)

Cross Section (in2)

Breaking Load (lb)

Weight /MFT (lb)

4 MG3 5 MG3 6 MG 6.6 MG 7 MG3 8 MG 5/16 in. MG3 10 MG 5/16 in. MG 11.5 MG 12.5 MG 3/8 in. MG 14 MG 16 MG 18 MG 7/16 in. MG 20 MG 1/2 in. MG 25 MG

3/0.102 3/0.114 7/0.081 7/0.083 3/0.128 7/0.191 3/0.141 7/0.102 7/0.104 7/0.110 7/0.114 7/0.121 7/0.121 7/0.128 7/0.139 7/0.145 7/0.148 7/0.165 7/0.173

3/10 AWG 3/9 AWG 7/12 AWG N/A 3/8 AWG 7/11 AWG 3/7 AWG 7/10 AWG N/A N/A 7/9 AWG N/A N/A 7/8 AWG N/A 7/7 AWG N/A N/A N/A

0.220 0.247 0.242 0.249 0.277 0.272 5/16 0.306 5/16 0.330 0.343 3/8 0.363 0.386 0.417 7/16 0.444 1/2 0.519

0.0245 0.0306 0.0361 0.0379 0.0386 0.0455 0.0495 0.0572 0.0595 0.0665 0.0714 0.0792 0.0805 0.0901 0.1062 0.1156 0.1204 0.1497 0.1645

4,500 5,600 6,300 6,600 7,100 8,000 8,400 10,000 10,400 11,600 12,500 13,800 14,100 16,000 18,000 18,700 20,000 22,900 25,000

70.61 88.18 104.1 109.3 111.2 131.4 142.7 165.1 171.6 192.0 206.2 228.0 232.2 260.0 306.6 333.6 347.5 432.0 474.8

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

106


Return to Table of Contents

ACSR Steel Reinforced Bare Aluminum Conductor Applications Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. Construction Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; “aluminized” aluminum coated (AZ); or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease. Specifications ACSR bare conductor meets or exceeds the following ASTM specifications: • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes • B-231 Aluminum Conductors, Concentric-Lay-Stranded • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) • B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) • B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) • B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) Notes • Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60Hz. • Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft sun, .05 coefficients of emissivity and absorption.

Item #

Size AWG

Turkey Swan Swanate Sparrow Sparate Robin Raven Quail Pigeon Penguin Waxwing Partridge Ostrich Merlin Linnet Oriole Chickadee Brant Ibis Lark Pelican Flicker

6 4 4 2 2 1 1/0 2/0 3/0 4/0 266.8 266.8 300.0 336.4 336.4 336.4 397.5 397.5 397.5 397.5 477.0 477.0

Stranding Diameter Diameter Diameter Diameter Weight (Al/Stl) Individual Individual Steel Core Complete /MFT Wire Wire (in) Cable Aluminum Aluminum Steel O.D. (lb) (in) (in) (in) 6/1 6/1 7/1 6/1 7/1 6/1 6/1 6/1 6/1 6/1 18/1 26/7 26/7 18/1 26/7 30/7 18/1 24/7 26/7 30/7 18/1 24/7

0.0661 0.0834 0.0772 0.1052 0.0974 0.1181 0.1327 0.1489 0.1672 0.1878 0.1217 0.1013 0.1074 0.1367 0.1137 0.1059 0.1486 0.1287 0.1236 0.1151 0.1628 0.1410

0.0661 0.0834 0.1029 0.1052 0.1299 0.1181 0.1327 0.1489 0.1672 0.1878 0.1217 0.0788 0.0835 0.1367 0.0884 0.1059 0.1486 0.0858 0.0961 0.1151 0.1628 0.0940

0.0661 0.0834 0.1029 0.1052 0.1299 0.1181 0.1327 0.1489 0.1672 0.1878 0.1217 0.2364 0.2505 0.1367 0.2642 0.3117 0.1486 0.2574 0.2882 0.3453 0.1628 0.2820

0.198 0.250 0.257 0.316 0.325 0.354 0.398 0.447 0.502 0.563 0.609 0.642 0.680 0.683 0.720 0.741 0.743 0.772 0.783 0.806 0.814 0.846

24.5 39.0 39.0 62.0 62.0 78.2 98.7 124.3 156.7 197.7 250.3 251.7 282.9 315.8 317.1 318.2 373.1 375.0 374.7 375.8 447.8 450.1

Weight /MFT Steel (lb)

Weight /MFT Total (lb)

11.6 18.4 28.0 29.3 44.7 36.9 46.6 58.7 74.0 93.4 39.2 115.6 129.8 49.5 145.4 208.9 58.5 137.0 171.9 246.8 70.2 164.4

36.1 57.4 67 91.3 106.7 115.1 145.3 183 230.7 291.1 289.5 367.2 412.7 365.2 462.5 527.1 431.6 512 546.6 622.6 518 614.5

Rated Allowable Breaking Ampacity Strength (amp) (lb) 1190 1860 2360 2850 3640 3550 4380 5300 6620 8350 6880 11300 12700 8680 14100 17800 9940 14500 16300 20300 11800 17200

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Rating (amp)

105 140 140 184 184 212 242 276 315 357 449 475 492 519 529 535 576 584 587 594 646 655

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

401


Return to Table of Contents

ACSR Steel Reinforced Bare Aluminum Conductor Item #

Hawk Hen Osprey Parakeet Dove Eagle Peacock Squab Wood Duck Teal Kingbird Swift Rook Grosbeak Scoter Egret Flamingo Gannet Stilt Starling Redwing Coot Cuckoo Drake Tern Condor Mallard Ruddy Canary Rail Cardinal Ortolan Curlew Bluejay Finch Bunting Grackle Bittern Pheasant Dipper Martin Bobolink Plover Nuthatch Parrot

Size AWG

477.0 477.0 556.5 556.5 556.5 556.5 605.0 605.0 605.0 605.0 636.0 636.0 636.0 636.0 636.0 636.0 666.6 666.6 715.5 715.5 715.5 795.0 795.0 795.0 795.0 795.0 795.0 900.0 900.0 954.0 954.0 1033.5 1033.5 1113.0 1113.0 1192.5 1192.5 1272.0 1272.0 1351.5 1351.5 1431.0 1431.0 1510.5 1510.5

Stranding Diameter Diameter Diameter Diameter Weight (Al/Stl) Individual Individual Steel Core Complete /MFT Wire Wire (in) Cable Aluminum Aluminum Steel (O.D.) (lb) (in) (in) (in) 26/7 0.1354 0.1053 0.3159 0.858 449.6 30/7 0.1261 0.1261 0.3783 0.883 451.1 18/1 0.1758 0.1758 0.1758 0.879 522.2 24/7 0.1523 0.1015 0.3045 0.914 525.1 26/7 0.1463 0.1138 0.3414 0.927 525.0 30/7 0.1362 0.1362 0.4086 0.953 526.3 24/7 0.1588 0.1059 0.3177 0.953 570.9 26/7 0.1525 0.1186 0.3558 0.966 570.4 30/7 0.1420 0.1420 0.4260 0.994 572.0 30/19 0.1420 0.0852 0.4260 0.994 572.0 18/1 0.1880 0.1880 0.1880 0.940 597.2 36/1 0.1329 0.1329 0.1329 0.930 596.9 24/7 0.1628 0.1085 0.3255 0.977 600.0 26/7 0.1564 0.1216 0.3648 0.990 597.9 30/7 0.1456 0.1456 0.4368 1.019 601.4 30/19 0.1456 0.0874 0.4370 1.019 601.4 24/7 0.1667 0.1110 0.3330 1.000 629.1 26/7 0.1601 0.1245 0.3730 1.014 628.7 24/7 0.1727 0.1151 0.3453 1.036 675.2 26/7 0.1659 0.1290 0.3870 1.051 675.0 30/19 0.1544 0.0926 0.4630 1.081 676.3 36/1 0.1486 0.1486 0.1486 1.040 746.2 24/7 0.1820 0.1213 0.3640 1.092 749.9 26/7 0.1749 0.1360 0.4080 1.108 750.3 45/7 0.1329 0.0886 0.2548 1.063 749.8 54/7 0.1213 0.1213 0.3639 1.092 749.5 30/19 0.1628 0.0977 0.4885 1.140 751.9 45/7 0.1414 0.0943 0.2829 1.131 848.7 54/7 0.1291 0.1291 0.3873 1.162 849.0 45/7 0.1456 0.0971 0.2913 1.165 899.9 54/7 0.1329 0.1329 0.3987 1.196 900.7 45/7 0.1515 0.1010 0.3030 1.212 974.3 54/7 0.1383 0.1383 0.4149 1.245 974.3 45/7 0.1573 0.1049 0.3147 1.259 1050.0 54/19 0.1436 0.0862 0.4310 1.293 1056.0 45/7 0.1628 0.1085 0.3255 1.302 1125.0 54/19 0.1486 0.0892 0.4460 1.338 1130.0 45/7 0.1681 0.1121 0.3363 1.345 1200.0 54/19 0.1535 0.0921 0.4605 1.382 1206.0 45/7 0.1733 0.1155 0.3465 1.386 1275.0 54/19 0.1582 0.9049 0.4745 1.424 1281.0 45/7 0.1783 0.1189 0.3567 1.427 1350.0 54/19 0.1628 0.0977 0.4885 1.465 1357.0 45/7 0.1832 0.1221 0.3663 1.465 1425.0 54/19 0.1672 0.1003 0.5015 1.505 1431.0

Weight /MFT Steel (lb)

Weight /MFT Total (lb)

205.4 296.2 81.8 191.7 241.0 345.6 208.7 261.8 375.6 367.4 93.6 46.8 219.1 276.2 394.9 386.6 229.7 288.5 246.5 309.7 434.0 58.5 273.8 344.2 146.1 273.6 483.1 165.5 309.9 175.5 328.4 189.8 355.6 204.8 276.1 219.1 402.7 233.9 429.3 248.3 455.8 263.1 483.1 277.4 509.2

656 747.3 604.1 716.9 766 871.8 779.6 832.2 947.7 939.4 690.8 643.7 819.1 874.1 996.3 988 858.8 917.1 921.8 984.7 1110 804.7 1024 1094 895.9 1023 1235 1014 1149 1075 1228 1164 1330 1255 1432 1344 1533 1433 1635 1525 1737 1613 1840 1702 1940

Rated Allowable Breaking Ampacity Strength (amp) (lb) 19500 23800 13700 19800 22500 27800 21600 24300 28900 30000 15700 13800 22600 25200 30400 31500 23700 26400 25500 28400 34600 16800 27900 31500 22100 28200 38400 24400 31900 25900 33800 27700 36600 29800 39100 32000 41900 34100 43500 36200 46300 38300 49100 40100 51700

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Rating (amp)

659 666 711 721 726 734 760 765 774 773 773 769 784 789 798 798 807 812 844 849 859 884 901 907 887 889 918 958 961 993 996 1043 1047 1092 1093 1139 1140 1184 1187 1229 1232 1272 1275 1313 1318

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 401

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

ACSR Steel Reinforced Bare Aluminum Conductor Item #

Size AWG

Lapwing 1590.0 Falcon 1590.0 Chukar 1780.0 Bluebird 2156.0 Kiwi 2167.0 Thrasher 2312.0 Joree 2515.0 High Mechanical Strength Grouse 80.0 Petrel 101.8 Minorca 110.8 Leghorn 134.6 Guinea 159.0 Dotterel 176.9 Dorking 190.8 Brahma 203.2 Cochin 211.3

Stranding Diameter Diameter Diameter Diameter Weight (Al/Stl) Individual Individual Steel Core Complete /MFT Wire Wire (in) Cable Aluminum Aluminum Steel O.D. (lb) (in) (in) (in) 45/7 0.1880 0.1253 0.3759 1.504 1498.0 54/19 0.1716 0.1030 0.5150 1.545 1507.0 84/19 0.1456 0.0874 0.4370 1.602 1688.0 84/19 0.1602 0.0961 0.4805 1.762 2044.0 72/7 0.1735 0.1157 0.3471 1.735 2055.0 76/19 0.1744 0.0814 0.4070 1.802 2191.0 76/19 0.1819 0.0849 0.4245 1.880 2384.0 8/1 12/7 12/7 12/7 12/7 12/7 12/7 16/19 12/7

0.1000 0.0921 0.0961 0.1059 0.1151 0.1214 0.1261 0.1227 0.1327

0.1670 0.0921 0.0961 0.1059 0.1151 0.1214 0.1261 0.0977 0.1327

0.1670 0.2763 0.2883 0.3177 0.3453 0.3642 0.3783 0.4885 0.3981

0.367 0.461 0.481 0.530 0.576 0.607 0.631 0.714 0.664

75.1 96.0 104.5 127.0 150.0 166.9 180.0 191.7 199.3

Weight /MFT Steel (lb)

Weight /MFT Total (lb)

Rated Allowable Breaking Ampacity Strength (amp) (lb)

Rating (amp)

292.2 537.0 386.6 467.4 248.9 335.4 364.8

1793 2044 2975 2511 2303 2527 2749

42200 54500 51000 60300 49800 56700 61700

N/A N/A N/A N/A N/A N/A N/A

1354 1359 1453 1623 1607 1673 1751

73.9 158.0 172.1 208.9 246.8 274.6 296.3 485.0 328.2

149 254 276 336 396 441 476 675 527

5200 10400 11300 13600 16000 17300 18700 28400 20700

204 237 246 273 297 312 324 341 340

N/A N/A N/A N/A N/A N/A N/A N/A N/A

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

401


Return to Table of Contents

AAC Bare Aluminum Conductor Applications Stranded 1350 aluminum conductors shown in this section of data are classified as follows: Class AA For bare conductors usually used in overhead lines. Class A For conductors to be covered with weather-resistant materials and for bare conductors where greater flexibility is required.Compact strand conductor for use in bare overhead applications or for use with weather-resistant coverings or insulations is also available. Classes refer to stranding and are an indication of relative conductor flexibility, AA being the least flexible, C the most flexible. Construction Aluminum alloy 1350-H19 wires, concentrically stranded. Specifications AAC bare conductors meet or exceed the following ASTM specifications: • B-230 Aluminum Wire, 1250-H19 for Electrical Purposes • B-231 Aluminum Conductors, Concentric-Lay-Stranded • B-400 Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors Notes • Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60Hz. • Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft sun, .05 coefficients of emissivity and absorption.

Item #

Size AWG

No. of Wires

CLASS

Diameter Individual Wire (in)

Diameter Complete Cable O.D. (in)

Cross Sectional Area (in2)

Weight /MFT (lb)

Rated Breaking Strength (lb)

Peachbell Rose Iris Pansy Poppy Aster Phlox Oxlip Sneezewort Valerian Daisy Laurel Peony Tulip Daffodil Canna Goldentuft Cosmos Syringa Zinnia Hyacinth

6 4 2 1 1/0 2/0 3/0 4/0 250 250 266.8 266.8 300 336.1 350 397.5 450 477 477 500 500

7 7 7 7 7 7 7 7 7 19 7 19 19 19 19 19 19 19 37 19 37

A A A & AA A & AA A & AA A & AA A & AA A & AA AA A A & AA A A A A A & AA AA AA A AA A

.0612 .0772 .0974 .1093 .1228 .1379 .1548 .1739 .1890 .1147 .1953 .1185 .1257 .1331 .1357 .1447 .1538 .1584 .1135 .1622 .1162

.184 .232 .292 .328 .368 .414 .464 .522 .567 .574 .586 .593 .629 .666 .679 .724 .769 .793 .795 .811 .813

.0206 .0328 .0521 .0657 .0829 .1045 .1318 .1662 .1964 .1964 .2095 .2095 .2356 .2642 .2749 .3122 .3534 .3746 .3746 .3927 .329

24.6 39.2 62.3 99.1 78.5 124.9 157.5 198.6 234.7 234.7 250.5 250.5 286.1 315.8 328.6 373.2 422.4 447.8 447.8 469.4 469.4

563 881 1350 1640 1990 2510 3040 3830 4520 4660 4830 4970 5480 6150 6390 7110 7890 8360 8690 8760 9110

Resistance Resistance /MFT /MFT DC 20°C AC 75°C (ohm) (ohm) .658 .414 .260 .207 .164 .130 .103 .0817 .0691 .0691 .0648 .0648 .0576 .0514 .0494 .0435 .0384 .0362 .0362 .0346 .0346

.805 .506 .318 .252 .202 .159 .126 .0999 .0846 .0846 .0793 .0793 .0706 .0630 .0605 .0534 .0472 .0445 .0445 .0425 .0425

Rating (amp)

103 138 185 214 247 286 331 383 425 426 443 444 478 513 526 570 616 639 639 658 658

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

403


Return to Table of Contents

AAC Bare Aluminum Conductor Item #

Dahlia Mistletoe Meadowsweet Orchid Heuchera Verbena Flag Violet Nasturtium Petunia Cattail Arbutus Lilac Cockscomb Snapdragon Magnolia Goldenrod Hawkweed Camellia Bluebell Larkspur Marigold Hawthorn Narcissus Columbine Carnation Gladiolus Coreopsis Jessamine Cowslip Sagebrush Lupine Bitterroot Trillium Bluebonnet

Size AWG

No. of Wires

CLASS

Diameter Individual Wire (in)

Diameter Complete Cable O.D. (in)

Cross Sectional Area (in2)

Weight /MFT (lb)

Rated Breaking Strength (lb)

556.5 556.5 600 636 650 700 700 715.5 715.5 750 750 795 795 900 900 954 954 1000 1000 1033.5 1033.5 1113 1192.5 1272 1351.5 1431 1510.5 1590 1750 2000 2250 2500 2750 3000 3500

19 37 37 37 37 37 61 37 61 37 61 37 61 37 61 37 61 37 61 37 61 61 61 61 61 61 61 61 61 91 91 91 91 127 127

AA A A & AA A & AA AA AA A AA A AA A AA A AA A AA A AA A AA A A & AA A & AA A & AA A & AA A & AA A & AA AA AA A A A A A A

.1711 .1226 .1273 .1311 .1326 .1375 .1071 .1391 .1083 .1424 .1109 .1446 .1142 .1560 .1215 .1606 .1251 .1644 .1280 .1671 .1302 .1351 .1398 .1444 .1489 .1532 .1574 .1614 .1694 .1482 .1572 .1657 .1739 .1537 .1660

.856 .858 .891 .918 .928 .963 .964 .974 .975 .997 .998 1.026 1.028 1.092 1.094 1.124 1.126 1.150 1.152 1.170 1.172 1.216 1.258 1.300 1.340 1.379 1.417 1.454 1.525 1.630 1.729 1.823 1.913 1.996 2.158

.4371 .4371 .4712 .4995 .5105 .5498 .5498 .5620 .5620 .5891 .5891 .6244 .6244 .7069 .7069 .7493 .7493 .7854 .7854 .8117 .8117 .8742 .9366 .9990 1.062 1.124 1.186 1.249 1.374 1.571 1.767 1.964 2.160 2.356 2.749

522.4 522.4 563.2 597.0 610.2 657.1 657.1 671.7 671.7 704.0 704.0 746.3 746.3 844.9 844.9 895.6 895.6 938.7 938.7 970.2 970.2 1045 1119 1194 1269 1343 1418 1493 1643 1877 2131 2370 2607 2844 3350

9750 9940 10700 11400 11600 12500 12900 12800 13100 13100 13500 13900 14300 15400 15900 16400 16900 17200 17700 17700 18300 19700 21000 22000 23400 24300 25600 27000 29700 32200 37500 41900 46100 50300 58700

Resistance Resistance /MFT /MFT DC 20°C AC 75°C (ohm) (ohm) .0311 .0311 .0288 .0272 .0266 .0247 .0247 .0242 .0242 .0230 .0230 .0217 .0217 .0192 .0192 .0181 .0181 .0173 .0173 .0167 .0167 .0155 .0145 .0136 .0128 .0121 .0144 .0109 .00988 .00864 .00776 .00698 .00635 .00582 .00499

.0382 .0382 .0355 .0335 .0328 .0305 .0305 .0299 .0299 .0286 .0286 .0271 .0270 .0239 .0239 .0226 .0226 .0216 .0216 .0210 .0210 .0195 .0183 .0173 .0163 .0155 .0147 .0141 .0129 .0115 .0105 .00969 .00900 .00834 .00756

Rating (amp)

703 704 738 765 775 812 812 823 823 847 847 878 879 948 948 982 983 1010 1011 1031 1032 1079 1124 1169 1212 1253 1294 1333 1408 1518 1612 1706 1793 1874 2024

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 403

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

AAAC 6201 Alloy Bare Aluminum Conductor Applications Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a highstrength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives AAAC higher resistance to corrosion than ACSR. Construction Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399, are concentric-lay stranded, similar in construction and appearance to 1350 grade aluminum conductors. Standard 6201 alloy conductors are similar to other alloy conductors commercially known as Ardival, Aldrey or Almelec. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core. The DC resistance at 20°C of the 6201-T81 conductors and of the standard ACSRs of the same diameter are approximately the same. Conductors of the 6201-T81 alloys are harder and, therefore, have a greater resistance to abrasion than conductors of 1350-H19 grade aluminum. Specifications AAAC bare conductor meets or exceeds the following ASTM specifications: • B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes • B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors. Notes • Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60Hz. • Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft sun, .05 coefficients of emissivity and absorption

Item #

Akron Alton Ames Azusa Anaheim Amherst Alliance Butte Canton Cairo Darien Elgin Flint Greely

Size KCM KCM

Strand

Approx EC Cond. with Equivalent Resistance

Stranding

Diameter Individual Wire (in)

Diameter Complete Cable (in)

Cross Sectional Area (in2)

Weight /MFT (lb)

Rated Breaking Strength (lb)

Rating (amp)

30.58 48.69 77.47 123.3 155.4 195.7 246.9 312.8 394.5 465.4 559.5 652.4 740.8 927.2

7/w 7/w 7/w 7/w 7/w 7/w 7/w 19/w 19/w 19/w 19/w 19/w 37/w 37/w

6 4 2 1/0 2/0 3/0 4/0 266.8 336.4 397.5 477.0 556.5 636.0 795.0

6/1 6/1 6/1 6/1 6/1 6/1 6/1 26/7 26/7 26/7 26/7 26/7 26/7 26/7

.0661 .0834 .1052 .1327 .1490 .1672 .1878 .1283 .1441 .1565 .1716 .1853 .1415 .1583

.198 .250 .316 .398 .447 .502 .563 .642 .721 .783 .858 .927 .991 1.108

.0240 .0382 .0608 .0968 .1221 .1537 .1939 .2456 .3098 .3655 .4394 .5124 .5818 .7282

28.7 45.7 72.7 115.7 145.9 183.7 231.8 293.6 370.3 436.9 525.2 612.4 695.5 870.4

1110 1760 2800 4460 5390 6790 8560 11000 13300 15600 18800 21900 24400 30500

107 143 191 256 296 342 395 460 532 590 663 729 790 908

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

404


Return to Table of Contents

TP Twisted Pair Bare Aluminum Conductor Applications TP Twisted Pair Conductor bare aluminum construction, is designed for use in overhead applications subject to Aeolian vibration and galloping due to wind and ice. TP Conductor can be strung to the maximum allowable tension limits without the need for additional vibration protection. Construction TP Conductor is composed of two identical bare conductors twisted together with a left-hand lay. This gives the cable a rectangular spiral shape. This spiral shape disrupts the forces created by steady cross winds which cause cable vibration, by presenting a continuously changing projected cable diameter to the wind. This spiral shape, together with less torsional stiffness and varying bending stiffness also reduces or eliminates cable galloping due to combined ice and wind loads. The component conducts of TP can be conductor types AAC, AAAC, ACAR, ACSR, AAC/TW or ACSR/TW meeting the requirements of the appropriate ASTM standards. Specifications TP Conductor meets or exceeds the following ASTM specifications for the subconductor of each assembly: • B-911/B-911M for Twisted Pair Conductor • B-231 Aluminum Conductor, Concentric-Lay Stranded. • B-232 Aluminum Conductor, Concentric-Lay Stranded, Coated Steel Reinforced (ACSR). • B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors. • B-524 Concentric-Lay Stranded Aluminum Conductors, Aluminum Alloy Reinforced (ACAR, 1350/6201) • B-779 Shaped Wire Compact Concentric-Lay Stranded Aluminum Conductors, Steel Reinforced (ACSR/TW.) Notes • Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60Hz. • Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft sun, .05 coefficients of emissivity and absorption.

Item #

Lily TP Ames TP Swallow TP Iris TP SparrowTP Pansy TP Robin TP Poppy TP Azuza TP Raven TP Aster TP Anaheim TP Quail TP Phlox TP Amherst TP Pigeon TP Oxlip TP Alliance TP Penguin TP

Conductor Construction Type

AAC AAAC ACSR AAC ACSR AAC ACSR AAC AAAC ACSR AAC AAAC ACSR AAC AAAC ACSR AAC AAAC ACSR

2x#3 2x#2 2x#3 2x#2 2x#2 2x#1 2x#1 2x1/0 2x1/0 2x1/0 2x2/0 2x2/0 2x2/0 2x3/0 2x3/0 2x3/0 2x4/0 2x4/0 2x4/0

Total Kcmil

Stranding Aluminum

Stranding Steel

Outer Dimension (in)

Equivalent Diameter (in)

Weight /MFT Alum (lb)

Weight /MFT Steel (lb)

Weight /MFT Total (lb)

Rated Breaking Strength (lb)

Rating (amp)

105.2 154.9 105.2 132.7 132.7 167.4 167.4 211.2 246.6 211.2 266.2 310.8 266.2 335.6 391.4 335.6 423.2 493.8 423.2

7x0.0867 7x0.1052 6x0.0937 7x0.0974 6x0.1052 7x0.1093 6x0.1181 7x0.1228 7x0.1327 6x0.1327 7x0.1379 7x0.1490 6x0.1489 7x0.1548 7x0.1672 6x0.1672 7x0.1739 7x0.1878 6x0.1878

N/A N/A 1x0.0937 N/A 1x0.1052 N/A 1x0.1181 N/A N/A 1x0.1327 N/A N/A 1x0.1489 N/A N/A 1x0.1672 N/A N/A 1x0.1878

0.260x0.520 0.316x0.632 0.281x0.562 0.292x0.584 0.316x0.631 0.328x0.656 0.355x0.710 0.368x0.736 0.396x0.796 0.396x0.790 0.414x0.828 0.447x0.894 0.447x0.894 0.464x0.926 0.502x1.004 0.502x1.004 0.552x1.044 0.563x1.126 0.563x1.126

0.426 0.517 0.460 0.478 0.517 0.537 0.581 0.602 0.652 0.652 0.678 0.732 0.732 0.760 0.822 0.822 0.854 0.922 0.922

99.0 145.4 98.4 124.6 124.0 157.0 156.4 198.2 231.4 197.2 250.0 291.8 248.6 315.0 367.4 313.4 397.2 463.6 395.4

N/A N/A 46.4 N/A 59.0 N/A 74.0 N/A N/A 93.2 N/A N/A 117.6 N/A N/A 148.2 N/A N/A 188.8

99.0 145.4 144.8 124.6 183.0 157.0 230.4 198.2 231.4 290.4 250.0 291.8 366.2 315.0 367.4 462.0 397.2 463.6 582.2

2180 5600 4600 2700 5700 3280 7100 3980 8920 8760 5020 10780 10600 6080 13580 13240 7660 17120 16700

272 328 275 316 316 367 371 426 437 420 495 510 484 574 592 582 667 692 642

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

405


Return to Table of Contents

TP Twisted Pair Bare Aluminum Conductor Item #

Jaeger TP Daisy TP Butte TP Waxwing TP Partridge TP Tulip TP Merlin TP Linnett TP Canna TP Chickadee TP Ptarmigan TP Ibis TP Cosmos TP Pelican TP Taller TP Flicker-TP Hawk TP Dahila TP Flycatcher TP Creeper TP OspreyTP Kinglet TP Parakeet TP Dove TP Day Lily TP Kittiwake TP Squab TP Orchid TP Kingbird TP Turacos TP Rook TP Gloxinia TP Siskin TP Flamingo TP Violet TP Dunlin TP Arbutus TP Tern TP Drake TP Cockscomb TP Surfbird TP Twinstone TP Bluebell TP Marigold TP Ortolan TP Bluejay TP

Conductor Construction Type

ACSR AAC AAAC ACSR ACSR AAC ACSR ACSR AAC ACSR ACSR ACSR AAC ACSR ACSR ACSR ACSR AAC ACSR ACSR ACSR ACSR ACSR ACSR AAC ACSR ACSR AAC ACSR ACSR ACSR AAC ACSR ACSR AAC ACSR AAC ACSR ACSR AAC ACSR ACSR AAC AAC ACSR ACSR

2x228.2 2x266.8 2x266.8 2x266.8 2x266.8 2x336.4 2x336.4 2x336.4 2x397.5 2x397.5 2x397.5 2x397.5 2x477.0 2x447.0 2x477.0 2x477.0 2x477.0 2x556.5 2x516.8 2x516.8 2x556.5 2x556.5 2x556.5 2x556.5 2x596.0 2x596.0 2x605.0 2x636.0 2x636.0 2x636.0 2x636.0 2x666.6 2x666.6 2x666.6 2x715.5 2x715.5 2x795.0 2x795.0 2x795.0 2x900.0 2x874.5 2x900.0 2x1033.5 2x1113.5 2x1033.5 2x1113.0

Total Kcmil

Stranding Aluminum

456.4 18x0.1126 533.6 7x0.1953 533.6 19x0.1283 533.6 18x0.1217 533.6 26x0.1013 672.8 19x0.1331 672.8 18x0.1387 672.8 26x0.1137 795.0 19x0.1447 795.0 18x0.1486 795.0 20x0.1400 795.0 26x0.1236 954.0 19x0.1584 954.0 18x0.1628 954.0 20x0.1544 954.0 24x0.1410 954.0 26x0.1354 1113 19x0.1711 1033.5 18x0.1694 1033.5 20x0.1607 1113 18x0.1758 1113 20x0.1667 1113 24x0.1523 1113 26x0.1463 1192 19x0.1771 1192 18x0.1820 1210 20x0.1739 1272 37x0.1311 1272 18x0.1880 1272 20x0.1783 1272 24x0.1626 1333 37x0.1342 1334 20x0.1826 1334 24x0.1667 1431 37x0.1391 1431 20x0.1891 1590 37x0.1466 1590 45x0.1329 1590 26x0.1749 1800 37x0.1580 1749 20x0.2091 1800 20x0.2121 2067 37x0.1671 2226 61x0.1351 2067 45x0.1515 2226 45x0.1573

Stranding Steel

Outer Dimension (in)

1x0.1126 0.536x1.126 N/A 0.586x1.172 N/A 0.642x1.284 1x0.1217 0.609x1.218 7x0.0788 0.642x1.284 N/A 0.666x1.332 1x0.1367 0.684x1.368 7x0.0884 0.721x1.442 N/A 0.724x1.448 1x0.1486 0.743x1.486 7x0.0626 0.752x1.504 7x0.0961 0.783x1.566 N/A 0.793x1.586 1x0.1628 0.814x1.628 7x0.0686 0.823x1.647 7x0.0940 0.846x1.692 7x0.1053 0.858x1.716 N/A 0.856x1.712 1x0.1694 0.847x1.694 7x0.0714 0.857x1.714 1x0.1758 0.879x1.758 7x0.0741 0.889x1.778 7x0.1015 0.914x1.828 7x0.1138 0.927x1.854 N/A 0.886x1.771 1x0.1820 0.910x1.820 7x0.0773 0.928x1.855 N/A 0.918x1.836 1x0.1880 0.940x1.880 7x0.0792 0.951x1.902 7x0.1085 0.977x1.954 N/A 0.939x1.879 7x0.0812 1.974x1.948 7x0.1111 1.000x2.000 N/A 1.974x1.945 7x0.0840 1.005x2.016 N/A 1.026x2.052 7x0.0886 1.064x2.128 7x0.1360 1.108x2.216 N/A 1.092x2.184 7x0.0929 1.115x2.23 7x0.0943 1.131x2.262 N/A 1.170x2.340 N/A 1.216x2.432 7x0.1010 1.212x2.424 7x0.1049 1.258x2.516

Equivalent Diameter (in)

Weight /MFT Alum (lb)

Weight /MFT Steel (lb)

Weight /MFT Total (lb)

Rated Breaking Strength (lb)

Rating (amp)

0.922 0.959 1.051 0.997 1.051 1.090 1.120 1.180 1.185 1.216 1.231 1.282 1.298 1.333 1.347 1.385 1.405 1.401 1.387 1.403 1.439 1.455 1.496 1.518 1.450 1.490 1.518 1.503 1.539 1.557 1.599 1.538 1.594 1.637 1.594 1.650 1.680 1.742 1.814 1.788 1.825 1.851 1.915 1.991 1.984 2.059

428.5 501 587.2 501 504 632 632 634 746 746 747 750 896 896 895 900 900 1045 970 974 1044 1050 1050 1050 1119 1119 1141 1194 1194 1200 1200 1251 1258 1258 1343 1350 1493 1500 1500 1690 1650 1698 1940 2090 1948 2100

67.1 N/A N/A 78.6 230 N/A 100 292 N/A 118 146 344 N/A 140 175 328 414 N/A 152 190 164 204 384 482 N/A 175 222 N/A 186 234 438 N/A 246 450 N/A 262 N/A 292 688 N/A 322 332 N/A N/A 380 410

495.6 501 587.2 580 734 632 732 926 746 864 893 1094 896 1036 1070 1228 1314 1045 1122 1164 1208 1254 1434 1532 1119 1294 1383 1194 1380 1434 1638 1251 1504 1718 1343 1612 1493 1792 2188 1690 1972 2030 1940 2090 2328 2510

12200 9700 22000 13800 22600 12300 17400 28200 14200 19900 22200 32600 16700 23600 26400 34400 39000 19500 25500 28300 27400 30500 39600 45200 20400 29800 33200 22800 31400 34800 45400 23800 36600 47600 25600 39200 27800 44200 63000 30800 47600 48200 35400 39400 55400 59600

720 774 810 789 810 902 917 923 984 1001 1007 1030 1108 1128 1134 1153 1162 1224 1188 1194 1247 1254 1275 1290 1279 1304 1324 1335 1359 1368 1391 1375 1410 1434 1439 1474 1536 1577 1620 1658 1674 1703 1801 1882 1853 1939

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 405

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Galvanized Guy Wire All products meet or exceed REA specifications for the electrical and telecommunications industries as well as other industry standards: ASTM A2111, ASTM A363, ASTM A474, ASTM A475, ASTM A586, ASTM B500. Products can also be manufactured to meet your special requirements or specifications. Standard lengths available are: • 250 ft. and 500 ft. coils • 1,000 ft., 2,500 ft. and 5,000 ft. reels • Custom lengths to meet your job requirements

Item #

Strand Diameter (in)

GW5-3/16-062 GW6-3/16-065 GW7-7/32-072 GW8-1/4-080 GW9-9/32-093 GW10-5 /16-104 GW11-5 /16-109 GW12-3/8-120 GW13-7/16-145 GW14-1/2-165 GW15-9/16-188 GW16-5/8-207 GW17-1/2-100 GW18-9/16-113 GW19-5/8-125 GW20-3/4-150 GW21-7/8-177 GW22-1-200

Coated Number Diameter of Wires (in) per Strand

3/16 3/16 7/32 1/4 9/32 5/16 5/16 3/8 7/16 1/2 9/16 5/8 1/2 9/16 5/8 3/4 7/8 1

0.062 0.065 0.072 0.080 0.093 0.104 0.109 0.120 0.145 0.165 0.188 0.207 0.100 0.113 0.125 0.150 0.177 0.200

7 7 7 7 7 7 7 7 7 7 7 7 19 19 19 19 19 19

Approx. Utilities/ Common SiemensHigh Strand Specification Grade Martin Strength Weight Grade Min. Min. Grade Min. Grade Min. /MFT Breaking Breaking. Breaking Breaking (lb) Strength Strength Strength Strength (lb) (lb) (lb) (lb) 73 80 98 121 164 205 225 273 399 517 671 813 504 637 796 1155 1581 2073

2400 — — 4600 — 6000 11500 18000 25000 — — — — — — — —

1150 — 1540 1900 2570 3200 — 4250 5700 7400 9600 11600 7620 9640 11000 16000 21900 28700

1900 — 2560 3150 4250 5350 — 6950 9350 12100 15700 19100 12700 16100 18100 26200 35900 47000

2850 — 3850 4750 6400 8000 — 10800 14500 18800 24500 29600 19100 24100 28100 40800 55800 73200

Extra-High Min. Min. Min. Strength Weight Weight Weight Grade Min. of Coating of Coating of Coating Breaking CLASS A CLASS B CLASS C Strength (lb) (lb) (lb) (lb) 3990 — 5400 6650 8950 11200 — 15400 20800 26900 35000 42400 26700 33700 40200 58300 79700 104500

0.50 0.50 0.50 0.60 0.70 0.80 0.80 0.85 0.90 0.90 1.00 1.00 0.70 0.80 0.85 0.90 0.90 1.00

1.00 1.00 1.00 1.20 1.40 1.60 1.60 1.70 1.80 1.80 2.00 2.00 1.40 1.60 1.70 1.80 1.80 2.00

1.50 1.50 1.50 1.80 2.10 2.40 2.40 2.55 2.70 2.70 3.00 3.00 2.10 2.40 2.55 2.70 2.70 3.00

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2011, American Wire Group, Inc. Hallandale, Florida

107


Return to Table of Contents

Packaging Information: ACSR and ACSR/AW Steel Reinforced Bare Aluminum Conductor Code Word

Size Stranding Circular (ml or AWG)

Turkey

6

6/1

Swan

4

6/1

Swanate

4

7/1

Sparrow

2

6/1

Sparate

2

7/1

Robin

1

6/1

Raven

1/0

6/1

Quail

210

6/1

Pigeon

3/0

6/1

Penguin

4/0

6/1

Waxwing

266800

18/1

Owl Partridge Merlin

266800 266800 336400

6/7 26/7 18/1

Linnet

336400

26/7

Oriole

336400

30/7

Chickadee

397500

18/1

Brant

397500

24/7

Standard Packages Length Weight Reel (ft) (lb) Size

Code Word

5,400 16,340 3,835 15,420 3,580 17,910 8,955 2,410 19,390 9,695 6,465 2,250 11,250 5,625 1,910 15,380 7,690 5,125 1,515 12,180 6,090 4,060 9,660 4,830 3,220 7,670 3,835 2,555 6,080 3,040 2,025 14,370 7,185 4,555 10,330 11,390 5,695 16,410 8,205 9,430 9,430 9,640 9,640 4,820 12,790 6,395

Ibis

397500

26/7

Lark

397500

30/7

Pelican

477000

18/1

Flicker

477000

24/7

Hawk

477000

26/7

Hen

477000

30/7

Osprey

556500

18/1

Parakeet

556500

24/7

Dove

556500

26/7

Eagle

556500

30/7

Peacock

605000

24/7

Squab

605000

26/7

Teal

605000

30/19

Swift

636000

36/1

Kingbird

636000

18/1

Rook

636000

24/7

Grosbeak

636000

26/7

Egret

636000

30/19

195 590 220 885 240 1,200 600 220 1,700 885 590 240 1,200 600 220 1,770 885 590 220 1,770 885 590 1,770 885 590 1,770 885 590 1,770 885 590 4,160 2,080 1,560 3,795 4,160 2,080 7,590 3,795 4,970 4,970 4,160 4,160 2,080 6,550 3,275

Coil NR 30.22 Coil NR 36.22 Coil NR 38.22 NR 30.22 Coil NR 42.28 NR 36.22 NR 30.22 coji NR 38.22 NR 30.22 Coil NR 42.28 NR 36.22 NR 30.22 Coil NR 42.28 NR 36.22 NR 30.22 NR 42.28 NR 36.22 NR 30.22 NR 42.28 NR 36.22 NR 30.22 NR 42.28 NR 36.22 NR 30.22 NR 66.28 NR 48.28 NR 42.28 NR 60.28 NR 66.28 NR 48.28 RMT 84.36 NR 60.28 RM 66.32 NR 66.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.36 NR 60.28

Size Stranding Circular (ml or AWG)

Standard Packages Length Weight Reel (ft) (lb) Size 13,890 6,945 7,980 7,980 8,030 8,030 4,015 10,660 5,330 11,570 5,785 6,650 6,650 6,890 6,890 3,445 9,140 4,570 9,910 4,955 5,700 5,700 8,400 4,200 9,120 4,560 10,490 5,245 5,245 6,025 6,025 4,015 6,020 6,020 4,515 3,010 8,000 4,000 8,670 4,335 9,980 4,990 4,990

7,590 3,795 4,970 4,970 4,160 4,160 2,080 6,550 3,275 7,590 3,795 4,970 4,970 4,160 4,160 2,080 6,550 3,275 7,590 3,795 4,970 4,970 6,550 3,275 7,590 3,795 9,860 4,930 4,930 3,880 3,880 2,585 4,160 4,160 3,120 2,080 6,550 3,275 7,590 3,795 9,860 4,930 4,930

RMT 84.36 NR 60.28 RM 66.32 NR 66.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.36 NR 60.28 RMT 84.36 NR 60.28 RM 66.32 NR 66.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.36 NR 60.28 RMT 84.36 NR 60.28 RM 66.32 NR 66.28 RMT 84.36 NR 60.28 RMT 84.36 NR 60.28 RMT 84.45 RM 66.32 NR 66.28 RM 66.32 NR 66.28 NR 60.28 RM 66.32 NR 66.28 NR 60.28 NR 48.28 RMT 84.36 NR 60.28 RMT 84.36 NR 60.28 RMT 84.45 RM 66.32 RM 66.28

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

410


Return to Table of Contents

Packaging Information: ACSR and ACSR/AW Steel Reinforced Bare Aluminum Conductor Code Word

Size Stranding Circular (ml or AWG)

Flamingo

666600

24/7

Gannet

666600

26/7

Starling

715500

26/7

Redwing

715500

30/19

Coot

795000

36/1

Tern

795000

45/7

Cuckoo

795000

24/7

Condor

795000

54/7

Drake

795000

26/7

Mallard

795000

30/19

Ruddy

900000

45/7

Canary

900000

54/7

Catbird

954000

36/1

Rail

954000

45/7

Cardinal

954000

54/7

Ortolan

1033500

45/7

Curlew

1033500

54/7

Standard Packages Length Weight Reel (ft) (lb) Size

Code Word

11,440 7,630 3,815 12,410 8,270 4,135 11,560 7,710 3,855 8,880 4,440 4,440 9,640 4,820 4,820 12,000 6,000 4,000 9,600 6,400 3,200 11,520 5,760 10,400 6,940 3,470 7,980 3,990 3,990 10,590 5,295 10,180 5,090 8,030 4,015 4,015 14,990 9,990 4,995

9,830 6,550 3,275 11,380 7,590 3,795 11,380 7,590 3,795 9,860 4,930 4,930 7,760 3,880 3,880 10,750 5,375 3,585 9,830 6,550 3,275 11,800 5,900 11,380 7,590 3,795 9,860 4,930 4,930 10,750 5,375 11,800 5,900 7,760 3,880 3,880 16,125 10,750 5,375

RMT 84.45 RMT 84.36 NR 60.28 RMT 90.45 RMT 84.36 NR 60.28 RMT 90.45 RMT 84.36 NR 66.28 RMT 84.45 RM 66.32 NR 66.28 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 RM 68.38 NR 60,28 RMT 90.45 RMT 84.36 NR 60.28 RMT 90.45 RM 68.38 RMT 90.45 RMT 84.36 NR 60.28 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 84.45 RM 66.32 NR 66.28 RMT 96.60 RMT 90.45 RM 68.38

Bluejay

1113000

45/7

Finch

1113000

54/19

Bunting

1192500

45/7

Grackle

1192500

54/19

Bittern

1272000

45/7

Pheasant

1272000

54/19

Dipper

1351500

45/7

Martin

1351500

54/19

Bobolink

1431000

45/7

Plover

1431000

54/19

Nuthatch

1510500

45/7

Parrot

1510500

54/19

Lapwing

1590000

45/7

Falcon

1590000

54/19

Chukar Bluebird Kiwi Thrasher

1780000 2156000 2167000 2312000

84/19 84/19 72/7 76/19

9,600 4,800 13,850 9,230 4,615 8,870 4,435

11,800 5,900 16,125 10,750 5,375 11,800 5,900

RMT 90.45 RM 68.38 RMT 96.60 RW90.45 RM 68.38 RMT 90.45 RM 68.38

Joree

2515000

76/19

Size Stranding Circular (ml or AWG)

Standard Packages Length Weight Reel (ft) (lb) Size 12,850 8,570 4,285 2,855 8,190 4,095 12,000 8,000 4,000 7,650 3,825 11,245 7,500 3,750 7,170 3,585 10,585 7,060 3,530 6,750 3,375 10,000 6,660 3,335 6,370 3,185 9,470 6,310 3,155 6,040 3,020 9,000 6,000 3,000 5,730 2,865 9,200 7,500 7,000 9,500 6,940 8,730

16,125 10,750 5,375 3,585 11,720 5,860 16,125 10,750 5,375 11,720 5,860 16,125 10,750 5,375 11,720 5,860 16,125 10,750 5,375 11,720 5,860 16,125 10,750 5,375 11,720 5,860 16,125 10,750 5,375 11,720 5,860 16,125 10,750 5,375 11,720 5,860 19,080 18,830 16,120 24,000 17,530 24,000

RMT 96.60 RMT 90.45 RM 68.38 NR 60.28 RMT 90.45 RM 68.38 RMT 96.60 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT 96.60 RMT 96.60 RMT 108.74 RMT 96.60 RMT 108.74

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 410

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Packaging Information: ACSR and ACSR/AW Steel Reinforced Bare Aluminum Conductor Code Word Petrel Minorca Leghorn Guinea Dotterel Dorking Brahma Cochin

Size Stranding Circular (ml or AWG) 101800 110800 134600 159000 176900 190800 203200 211300

12/7 12/7 12/7 12/7 12/7 12/7 16/19 12/7

Standard Packages Length Weight Reel (ft) (lb) Size 12,500 11,480 9,450 8,000 7,195 6,665 7,875 6,020

3,175 3,175 3,175 3,175 3,175 3,175 5,330 3,175

NR 48.28 NR 48.28 NR 48.28 NR 48.28 NR 48.28 NR 48.28 NR 60.28 NR 48.28

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

410


Return to Table of Contents

Packaging Information: AAC Bare Aluminum Conductor Code Word

Size Stranding Circular (ml or AWG)

Peachbell

6

7

Rose

4

7

Iris

2

7

Pansy

1

7

Poppy

1/0

7

Aster

2/0

7

Phlox

3/0

7

Oxlip

4/0

7

Sneezewort

250000

7

Valerian

250000

19

Daisy

266800

7

Laurel

266800

19

Peony

300000

19

Tulip

336400

19

Standard Packages Length Weight Reel (ft) (lb) Size

Code Word

56,910 28,455 8,130 35,710 17,855 5,100 22,470 11,235 3,210 17,830 8,915 2,550 14,130 7,065 2,020 11,210 5,605 8,890 4,445 7,050 3,525 5,970 2,985 16,190 16,190 8,095 5,590 2,795 15,170 15,170 7,585 13,490 13,490 6,745 12,030 12,030 6,015

Daffodil

350000

19

Canna

397500

19

Golden Tuft

450000

19

Cosmos

477000

19

Syringa

477000

37

Zinnia

500000

19

Hyacinth

500000

37

Dahlia

556500

19

Mistletoe

556500

37

Meadowsweet 600000

37

Orchid

636000

37

Heuchera

650000

37

1,400 700 200 1,400 700 200 1,400 700 200 1,400 700 200 1,400 700 200 1,400 700 1,400 700 1,400 700 1,400 700 3,800 3,800 1,900 1,400 700 3,800 3,800 1,900 3,800 3,800 1,900 3,800 3,800 1,900

NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 NR 42.28 NR 36.22 NR 42.28 NR 36.22 NR 42.28 NR 36.22 RM 66.32 NR 66.28 NR 48.28 NR 42.28 NR 36.22 RM 66.32 NR 66.28 NR 48.28 RM 66.32 NR 66.28 NR 48.28 RM 66.32 NR 66.28 NR 48.28

Size Stranding Circular (ml or AWG)

Standard Packages Length Weight Reel (ft) (lb) Size 11,560 11,560 5,780 10,180 10,180 5,090 9,000 9,000 4,500 8,490 8,490 4,245 16,530 8,265 8,265 8,100 8,100 4,050 15,760 7,880 7,880 7,270 7,270 3,635 14,170 7,085 7,085 13,140 6,570 6,570 12,400 6,200 6,200 12,130 6,065 6,065

3,800 3,800 1,900 3,800 3,800 1,900 3,800 3,800 1,900 3,800 3,800 1,900 7,400 3,700 3,700 3,800 3,800 1,900 7,400 3,700 3,700 3,800 3,800 1,900 7,400 3,700 3,700 7,400 3,700 3,700 7,400 3,700 3,700 7,400 3,700 3,700

RM 66.32 NR 66.28 NR 48.28 RM 66.32 NR 66.28 NR 48.28 RM 66.32 NR 66.28 NR 48.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.45 NR 66.32 NR 66.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.45 RM 66.32 NR 66.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.45 RM 66.32 NR 66.28 RMT 84.45 RM 66.32 NR 66.28 RMT 84.45 RM 66.32 NR 66.28 RMT 84.45 RM 66.32 NR 66.28

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

411


Return to Table of Contents

Packaging Information: AAC Bare Aluminum Conductor Code Word

Size Stranding Circular (mil) or AWG)

Verbena

700000

37

Flag

700000

61

Violet

715500

37

Nasturtium

715500

61

Petunia

750000

37

Cattail

750000

61

Arbutus

795000

37

Lilac

795000

61

Cockscomb

900000

37

Snapdragon

900000

61

Magnolia

954000

37

Goldenrod

954000

61

Standard Packages Length Weight Reel (ft) (lb) Size

Code Word

11,260 5,630 5,630 2,815 14,850 7,425 11,020 5,510 5,510 2,755 14,530 7,265 10,510 5,255 5,255 13,860 6,930 9,920 4,960 4,960 2,480 13,080 6,540 8,760 4,380 4,380 11,550 5,775 8,260 4,130 4,130 10,900 5,450

Hawkweed

1000000

37

Camellia

1000000

61

Bluebell

1033500

37

Larkspur

1033500

61

Marigold

1113000

61

Hawthorn

1192500

61

Narcissus

1272000

61

Columbine

1351500

61

Carnation

1431000

61

Gladiolus

1510500

61

Coreopsis

1590000

61

Jassamine Cowslip Sagebrush Lupine Bitterroot Trillium Bluebonnet

1750000 2000000 2250000 2500000 2750000 3000000 3500000

61 91 91 91 91 127 127

7,400 3,700 3,700 1,850 9,760 4,800 7,400 3,700 3,700 1,850 9,760 4,800 7,400 3,700 3,700 9,760 4,880 7,400 3,700 3,700 1,850 9,760 4,880 7,400 3,700 3,700 9,760 4,880 7,400 3,700 3,700 9,760 4,880

RMT 84.45 RM 66.32 NR 66.28 NR 48.28 RMT 90.45 RM 68.38 RMT 84.45 RM 66.32 NR 66.28 NR 48.28 RMT 90.45 RM 68.38 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 NR 68.38 RMT 84.45 RM 66.32 NR 66.28 NR 48.28 RMT 90.45 RM 68.38 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 RM 68.38 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 RM 68.38

Size Stranding Circular (mil) or AWG)

Standard Packages Length Weight Reel (ft) (lb) Size 7,880 3,940 3,940 10,400 5,200 7,630 3,815 3,815 10,060 5,030 9,430 4,670 8,720 4,360 8,170 4,085 7,690 3,845 7,270 3,635 6,880 3,440 6,540 3,270 5,940 4,850 4,270 3,840 3,490 3,350 2,840

7,400 3,700 3,700 9,760 4,880 7,400 3,700 3,700 9,760 4,880 9,760 4,880 9,760 4,880 9,760 4,880 9,760 4,880 9,760 4,880 9,760 4,880 9,760 4,880 9,760 9,100 9,100 9,100 9,100 9,530 9,530

RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 NR 68.38 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT90.45 RM 68.38 RMT90.45 RM 68.38 RMT 90.45 RMT 90.45 RMT 90.45 RMT 90.45 RMT 90.45 RMT 90.45 RMT 90.45

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 411

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Packaging Information: AAAC 6201 Alloy Bare Aluminum Conductor Code Word

Approx EC Size Cond. with Circular Equivalent (mil) Resistance

Akron

6

30580

Alton

4

48690

Ames

2

77470

Azusa

1/0

123300

Anaheim

2/0

155400

Amherst

3/0

195700

Alliance

4/0

246900

266.8

312800

Butte

Standard Packages Length Weight Reel (ft) (lb) Size

Code Word

48,780 24,390 6,970 30,630 15,315 4,375 19,260 9,630 2,750 12,100 6,050 1,730 9,600 4,800 7,600 3,810 6,040 3,020 12,940 12,940 6,470 4,315

Canton

336.4

394500

Cairo

397.5

465400

Darien

477.0

559500

Elgin

556.5

652400

Flint

636.0

740800

Greeley

795.0

927200

1,400 700 200 1,400 700 200 1,400 700 200 1,400 700 200 1,400 700 1,400 700 1,400 700 3,800 3,800 1,900 1,265

NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 NR 42.28 NR 36.22 NR 42.28 NR 36.22 RM 66.32 NR 66.28 NR 48.28 NR 42.28

Note Length Tolerances: Standard lengths shown in these data are nominal. The allowable tolerance shall be plus or minus 5% for sizes larger than 77470 kcmil.

Approx EC Size Cond. with Circular Equivalent (mil) Resistance

Standard Packages Length Weight Reel (ft) (lb) Size 10,260 10,260 5,130 3,420 8,700 8,700 4,350 2,900 7,240 7,240 3,620 2,415 6,210 6,210 3,105 2,070 10,640 5,320 5,320 2,660 8,500 4,250 4,250 2,125

3,800 3,800 1,900 1,265 3,800 3,800 1,900 1,265 3,800 3,800 1,900 1,265 3,800 3,800 1,900 1,265 7,400 3,700 3,700 1,850 7,400 3,700 3,700 1,850

RM 66.32 NR 66.28 NR 48.28 NR 42.28 RM 66.32 NR 66.28 NR 48.28 NR 42.28 RM 66.32 NR 66.28 NR 48.28 NR 42.28 RM 66.32 NR 66.28 NR 48.28 NR 42.28 RMT 84.45 RM 66.32 NR 66.28 NR 48.28 RMT 84.45 RM 66.32 NR 66.28 NR 48.28

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

8Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

412


Return to Table of Contents

Packaging Information: TP Twisted Pair Bare Aluminum Conductors Bare Aluminum Cable ACSR ACSR/TP Code Size Word Circular (ml or AWG) Swallow TP

2x#3-6/1

Sparrow TP

2x#2-6/1

Robin TP

2x#1-6/1

Raven TP

2xl/0-6/1

Quail TP

2x2/0-6/1

Pigeon TP

2x3/0-6/1

Penguin TP

2x4/0-6/1

Waxwing TP

2x266.6-18/1

Partridge TP

2x266.8-26/7

Merlin TP

2x336.4-18/1

Linnet TP

Chickadee TP

2x336.4-26/7

2x397.5-18/1

Length (ft) 12205 24410 9650 19390 7685 15370 6050 12100 4825 9650 3825 7650 3025 6050 5375 7180 14360 5150 10300 3775 5650 11300 4050 8100 16200 4800 9600

Standard Packages Weight Reel (lb) Size 1770 3540 1770 3540 1770 3540 1770 3540 1770 3540 1770 3540 1770 3540 3115 4180 8320 3795 7590 2770 4180 8320 3785 7595 15180 4160 8320

48.28 NR 60.28 NR 48.28 NR 60.28NR 48.28 NR 60.28 NR 48.28 NR 60.28 NR 48.28 NR 60.28 NR 48.28 NR 60.28 NR 48.28 NR 66.28 NR 66.28NR 68.38 NR 90.45 RMT 66.28 NR 90.45 RMT 66.28 NR 68.38 NR 90.45 RMT 66.28 NR 90.45 RMT 96.60 RMT 68.38 RM 90.45 RMT

Bare Aluminum Cable ACSR ACSR/TP Code Size Word Circular (ml or AWG) Ptarmigan TP

2x397.5-20/7

lbis TP

2x397.5-26/7

Pelican TP

2x477.0-18/1

Tatler TP

2x477.0-20/7

Flicker TP

2x477.0-24/7

Hawk TP

2x477.0-26/7

Creeper TP

2x517.0-18/1

Osprey TP

2x556.5-18/1

Parakeet TP

2x556.5-24/7

Dove TP

2x556.5-26/7

Rook TP Drake TP

2x636.0-24/7 2x795.0-26/7

Tern TP

2x795.0-45/7

Bluejay TP

2x1113.0-45/7

Length (ft) 5400 10800 6925 13850 4000 8000 4450 8900 5330 10660 5750 11500 3710 7420 3425 6850 4570 9140 4950 9900 8000 3450 6900 4000 6000 5650

Standard Packages Weight Reel (lb) Size 4780 9570 7590 15180 4160 8320 4780 9570 6550 13100 7590 15180 4160 8320 4160 8320 6550 13100 7590 15180 13100 7590 15180 7170 10750 14180

84.36 RMT 90.45 RMT 84.45 RMT 96.60 RMT 68.38 RM 90.45 RMT 66.38 RM 90.45 RMT 84.45 RMT 96.60 RMT 84.45 RMT 96.60 RMT 68.38 RM 94.45 RMT 68.38 RM 90.45 RMT 68.38 RM 90.45 RMT 90.45 RMT 95.60 RMT 96.60 RMT 84.45 RMT 96.60 RMT 90.45 RMT 96.60 RMT 96.60 RMT

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

413


Return to Table of Contents

Packaging Information: TP Twisted Pair Bare Aluminum Conductor Bare Aluminum Cable AAC AAC/TP Code Size Word Circular (ml or AWG) Lily TP

2x#3-7

Iris TP

2x#2-7

Pansy TP

2x#1-7

Poppy TP

2xl/0-7

Aster TP

2x2/0-7

Phlox TP

2x3/0-7

Oxlip TP

2x4/0-7

Valerian TP

2x250.0-19

Tulip TP

2x336.4-19

Canna TP

2x397.5-19

Cosmos TP

2x477.0-19

Dahlia TP

2x556.5-19

Length (ft) 7090 14180 28360 11250 21000 8915 17830 7050 14100 5600 11200 4450 9900 3550 7100 6800 16000 5300 6010 12020 4400 5090 10180 3600 4245 8490 3125 3635 7250

Standard Packages Weight Reel (lb) Size 700 1400 2800 1400 2615 1400 2800 1400 2800 1400 2800 1400 2800 1400 2800 3190 7510 3285 3800 7600 3280 3800 7600 3225 3800 7600 3265 3800 7600

42.24 NR 48.48 NR 60.28 NR 48.28 NR 60.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 66.28 NR 84.36 RMT 66.28 NR 68.38 NR 84.36 RMT 66.28 NR 68.36 NR 84.36 RMT 66.28 NR 68.38 NR 90.45 NR 66.28 NR 68.38 NR 90.45 RMT

Bare Aluminum Cable AAC AAAC Alloy 3201/TP Code Size Word Circular (ml or AWG) Ames TP

2x#2-7

Azusa TP

2x1/0-7

Anaheim TP

2x2/0-7

Amherst TP

2x3/0 -7

Alliance TP

2x4/0-7

Butte TP

2x266.8-19

Length (ft) 9,700 19,400 6,050 12,100 4,800 9,600 3,810 7,625 3,020 6,040 6,475

Standard Packages Weight Reel (lb) Size 1,410 3,540 1,400 2,822 1,400 2,800 1,400 2,800 1,400 2,800 3,800

48.28 NR 60.28 NR 48.28 NR 60.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 66.28 NR

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 413

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

OPGW Optical Ground Wire Fiber Colors 12 colors per EIA/TIA 598. Black ring banding used when more than 12 fibers per tube. Specifications Overall Cable Diameter: 0.528 in. (13.4 mm) 20.3% Aluminum-Clad Steel (ACS) Cross-Sectional Area: 0.10 in2 (67.7 mm2) 6201-T81 Aluminum Alloy (AY) Cross-Sectional Area: 0.05 in2 (33.8 mm2) Total Cross-Sectional Area: 0.16 in2 (101.5 mm2) Rated Breaking Strength (w/o SSLTs) (10% de-rating): 20,623 lb (91.7 kN) Unit Weight: 0.380 lb/ft (0.566 kg/m) Composite Material Modulus of Elasticity: 19,003 ksi (131.0 kN kgf/mm2) Coefficient of Thermal Expansion: 8.93E-06 1/°F (1.61E-05 1/°C) Lay Direction Of Outer Layer: Left DC Resistance at 20°C: 0.9021 OHM/mile (0.5606 OHM/km) Rated Short Circuit Current (0.5 sec): 12.0 kA Rated Fault Current (per IEEE 738) (40°C initial/210°C max. final hottest part of cable): 71.9 (kA)2 S Optical Fiber Count, Actual (Maximum): 24 Fiber Specifications or Data Sheets: G.652.D Max. Individual Attenuation, dB/km at 1310 nm/1550 nm: 0.35/0.25 Calculated Minimum Fiber Strain Margin (% RBS): 86% Min. Bending Radius (no load): 7 in (168 mm) Min. Bending Radius (with load): 8 in (201 mm) Standard Sheave Dia. (20% RBS): 23 in (584 mm) Sag and Tension Sag10 Chart No.: 1-1457

Designation

39AY68ACS-1C-1 39AY68ACS-1C-2 27AY59ACS-1C 32AY54ACS-1C 64AY37ACS-1C 34AY73ACS-1C 34AY74ACS-1C 68AY42ACS-1C 31AY87ACS-1C 39AY68ACS-1C-3 44AY75ACS-1C 75AY44ACS-1C 59AY66ACS-1C 79AY46ACS-1C 27AY59ACS-2C 59AY27ACS-2C 86ACS-2C 40AY100ACS-1C 56AY83ACS-1C 103AY40ACS-1C 101AY59ACS-1C 84AY76ACS-1C 27AY59ACS-3C 32AY54ACS-3C

Fiber Count (max)

Diameter (in)

Fault Duty (kA2s)

RBS (lb)

Weight (lb/ft)

Area (in2)

Sag10 Chart

12 12 16 16 20 24 24 24 24 24 24 24 24 24 32 32 32 36 36 36 36 36 48 48

0.528 0.528 0.472 0.472 0.512 0.528 0.531 0.534 0.555 0.528 0.555 0.555 0.571 0.571 0.472 0.472 0.472 0.602 0.602 0.606 0.646 0.646 0.472 0.472

74.8 71.9 46.3 48.1 75.1 68.9 74.1 88.0 84.5 71.9 91.7 103.9 109.8 116.2 41.9 49.4 28.8 118.0 123.1 153.9 190.1 179.7 37.7 39.2

19,468 20,620 16,536 15,613 13,987 21,771 20,928 15,529 24,105 20,620 21,555 16,455 20,098 17,402 15,310 10,692 20,851 26,909 25,716 17,073 21,902 25,249 14,083 13,159

0.365 0.380 0.305 0.293 0.286 0.395 0.386 0.316 0.438 0.380 0.404 0.337 0.391 0.356 0.293 0.232 0.366 0.502 0.479 0.368 0.454 0.499 0.281 0.269

0.16 0.16 0.13 0.13 0.15 0.16 0.16 0.16 0.17 0.16 0.17 0.17 0.18 0.18 0.12 0.12 0.12 0.20 0.20 0.21 0.24 0.24 0.11 0.11

1-1461 1-1457 1-1457 1-1461 1-1455 1-1427 1-1457 1-1170 1-1427 1-1457 1-1461 1-1455 1-536 1-1455 1-1450 1-1439 1-1140 1-1453 1-1450 1-1441 1-1455 1-536 1-1461 1-1444

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

601


Return to Table of Contents

OPGW Optical Ground Wire Designation

Fiber Count (max) 39AY68ACS-1C-4 48 59AY27ACS-3C 48 67AY32ACS-2C 48 34AY73ACS-2C 48 34AY74ACS-2C 48 49AY85ACS-2C 48 67AY32ACS-3C 72 40AY100ACS-2C 72 101AY47ACS-2C 72 101AY59ACS-2C 72 110AY51ACS-2C 72 59AY101ACS(27)-2C 72 191AY45ACS-3C 72 194AY74ACS-3C 144

Diameter (in) 0.528 0.472 0.506 0.528 0.531 0.591 0.506 0.602 0.620 0.646 0.646 0.646 0.785 0.836

Fault Duty (kA2s) 71.9 43.3 62.9 65.1 67.0 106.4 54.4 104.9 146.6 167.8 172.4 155.9 426.6 498.6

RBS (lb)

Weight (lb/ft)

Area (in2)

Sag10 Chart

20,620 10,389 12,292 19,090 19,376 22,478 11,915 24,642 18,418 21,336 19,662 24,617 19,735 23,121

0.380 0.232 0.267 0.365 0.370 0.435 0.267 0.476 0.397 0.451 0.428 0.517 0.504 0.599

0.16 0.11 0.13 0.15 0.15 0.19 0.13 0.19 0.21 0.22 0.22 0.22 0.34 0.37

1-1457 1-1439 1-1439 1-1450 1-1450 1-1461 1-1455 1-1457 1-1439 1-1170 1-1439 1-1427 1-1056 1-1056

Notes: *Many other designs are also available. *Specifications are subject to change without notice.

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 601

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

OPGW Cable & System Information Guide for Hardware Selection The following outline describes the OPGW cable information required to select proper cable attachment hardware and accessories. Most of the cable information can be found in the cable specification — it is recommended that this information be gathered along with the information about the cable system. Submit this information to American Wire Group to verify proper application. A. CABLE INFORMATION REQUIRED for DEAD-ENDS AND SUSPENSIONS 1. CABLE SPECIFICATIONS/Cable Specification Sheet Data a. Cable Diameter: Overall outer diameter of the OPGW. b. Cable Construction Strand Configuration: Lay Direction of outer wire strands, Distribution and Location of individual strand materials in a cross-section, Number of strand layers. c. Rated Breaking Strength d. Fault Current 2. CABLE SYSTEM a. Maximum Vertical Load at Hardware Attachment b. Line Angles In addition to the outline above, other products offered for OPGW applications require further information as listed in Part B below. B. ADDITIONAL INFORMATION FOR OTHER HARDWARE ACCESSORIES 1. Splice Closures, Closures, and Domes a. Fiber Count b. Fiber Type c. Fiber Optic Element Configuration d. Type of Buffer Tubes (plastic or stainless steel) e. Core construction (Solid, Aluminum Tube, Aluminum Channel), 2. Spiral Vibration Damper a. Span Lengths b. Final Tension at the Average Annual Minimum Temperature (AAMT) c. Terrain 3. FITTINGS (Y-Clevis, Clevis Eye, Yoke Plates), Ground Wire, Downlead Cushions, Cable Storage a. Interface at structure b. Type of Structure (Wood Pole, Concrete, Steel, Lattice Tower) c. Ground Wire Material, Bonding Material HARDWARE TESTS The IEEE 1138 Test Standard for OPGW includes a series of tests that require suitable hardware to demonstrate system performance. System tests include Tensile Strength, Vibration Test, and Galloping Tests among others. System tests require dead-ends and suspensions that can survive the test parameters and prove cable/hardware compatibility.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

602


Return to Table of Contents

ADSS All Dielectric Self-Supporting Fiber Optic Cable Applications The “All Dielectric Self-Supporting (ADSS)” cables are designed for aerial self-supporting applications at short, medium and long span distances. ADSS cables offer a rapid and economical means for deploying optical fiber cables along existing aerial rights-of-way. They are being deployed by cable television operators, telephone companies, municipalities and emerging network operators, in addition to electric power utilities. Construction The ADSS cable consists of a number of tubes/elements according to the specified number of fibers. The elements are usually fiber-containing tubes; however fillers may be used to preserve the cable geometry. Two to twelve color-coded fibers are loosely laid in each tube which is filled with a water-blocking gel. The tubes are stranded around a dielectric central strength member and bound in a jacket. A water-swelling tape is helically wrapped around the cable core. Aramid yarn strength members are helically laid to supply peripheral strengthening of the cable. The outer jacket is tightly bound over the aramid yarn layer. For long span applications a double jacket design can be considered. A ripcord is located under each jacket layer to facilitate its removal. For up to 30 fiber cables, the “ADSB” design is applicable, for 32-144 fibers the “ADSC” design is applicable. Dry cable designs, ballistic protection and other cable designs are available upon request.. Standards • Cables are designed for aerial installation according to IEEE-P1 222 • Cables tested according to TIA/EIA-455 and IEC-60794-1. • Cables meet or exceed Telcordia (Bellcore) requirements for outside plant cables (GR-20) when the appropriate options are chosen. Default Jacket Colors PE HFFR SM Fibers Black Yellow MM Fibers Black Orange Other jacket colors may be available, please specify. Sag Chart Below are the coefficients for a standard ADSS cable containing 32 to 60 fibers in 5 tubes with a single outer jacket. The cable can be used in a span of 450 feet with NESC light conditions, 300 feet for NESC medium and 240 feet for NESC heavy conditions. • Cross section area 0.196 in^2 • Outside diameter 0.5 in • Unit weight 0.081 lbs/ft • Ultimate tension 5800 lbs The following values are calculated at 68°F • Final modulus of elasticity 3248850 psi • Thermal expansion coefficient -2.78e-7°F • Stress strain A1 2973280 psi • Creep A1 2625190 psi

Item #

ADSS-1 ADSS-2 ADSS-3 ADSS-4 ADSS-5 ADSS-6 ADSS-7 ADSS-8 ADSS-9 ADSS-10 ADSS-11

ADS Series

Number of Elements

2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 32-60 ADSC 32-60 ADSC

5 5 5 5 5 5 5 5 5 5 5

Cable Weight (kg/km) 105 105 105 105 105 105 105 105 105 120 120

Cable Installation Diameter Tension (mm) (N)(2) 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 12.7 12.7

400 525 800 860 985 1255 1520 1785 1920 425 570

Span (m) (m)

Sag in Light (m)

Tension in Light (N)

Sag in Medium (m)

Tension in Medium (N)

Sag in Heavy (m)

Tension in Heavy (N)

30 40 60 70 80 100 120 135 150 30 40

0.16 0.22 0.37 0.46 0.54 0.71 0.89 1.01 1.16 0.16 0.23

1230 1540 2100 2300 2560 3040 3500 3870 4170 1310 1630

0.48 0.69 1.16 1.42 1.68 2.25 2.80 3.23 3.70 0.49 0.71

1600 1970 2650 2930 3240 3820 4380 4810 5180 1650 2030

0.66 0.95 1.6 2.27 2.33 — — — — 0.67 0.96

2370 2940 3900 4320 4755 — — — — 2430 3000

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

603


Return to Table of Contents

ADSS All Dielectric Self-Supporting Fiber Optic Cable Item #

ADSS-12 ADSS-13 ADSS-14 ADSS-15 ADSS-16 ADSS-17 ADSS-18 ADSS-19 ADSS-20 ADSS-21 ADSS-22 ADSS-23 ADSS-24 ADSS-25 ADSS-26 ADSS-27 ADSS-28 ADSS-29 ADSS-30 ADSS-31 ADSS-32 ADSS-33 ADSS-34 ADSS-35 ADSS-36 ADSS-37 ADSS-38 ADSS-39 ADSS-40 ADSS-41 ADSS-42 ADSS-43 ADSS-44 ADSS-45 ADSS-46 ADSS-47 ADSS-48 ADSS-49 ADSS-50 ADSS-51 ADSS-52 ADSS-53

ADS Series

Number of Elements

32-60 ADSC 32-60 ADSC 32-60 ADSC 32-60 ADSC 32-60 ADSC 32-60 ADSC 32-60 ADSC 32-60 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 122-144 ADSC 122-144 ADSC 122-144 ADSC 122-144 ADSC 122-144 ADSC 122-144 ADSC 122-144 ADSC

5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 12 12 12 12 12 12 12

Cable Weight (kg/km) 120 120 120 120 120 120 120 120 125 125 125 125 125 125 125 125 125 125 180 180 180 180 180 180 180 180 180 220 220 220 220 220 220 220 220 280 280 280 280 280 280 280

Cable Installation Diameter Tension (mm) (N)(2) 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 16 16 16 16 16 16 16 16 17.2 17.2 17.2 17.2 17.2 17.2 17.2

715 845 990 1120 1500 1780 1936 2200 443 580 795 950 1085 1240 1530 180 2080 2340 580 820 1000 1220 1400 1640 1960 2360 2640 834 1100 1290 1590 1860 2150 2690 3250 1030 1340 1720 2030 2440 2750 3470

Span (m) (m)

Sag in Light (m)

Tension in Light (N)

Sag in Medium (m)

Tension in Medium (N)

Sag in Heavy (m)

Tension in Heavy (N)

50 60 70 80 100 120 135 150 30 40 50 60 70 80 100 120 135 150 30 40 50 60 70 80 100 120 135 30 40 50 60 70 80 100 120 30 40 50 60 70 80 100

0.30 0.38 0.45 0.54 0.70 0.88 1.02 1.16 0.16 0.24 0.30 0.38 0.46 0.54 0.72 0.90 1.04 1.18 0.17 0.24 0.32 0.4 0.49 0.57 0.76 0.94 1.09 0.19 0.27 0.35 0.44 0.53 0.62 0.81 1.00 0.21 0.29 0.37 0.47 0.56 0.65 0.85

1940 2220 2520 2780 3340 3840 4150 4530 1320 1640 2000 2300 2570 2850 3350 3830 4220 4600 1500 1890 2220 2600 2890 3240 3790 4390 4800 1730 2150 2500 2910 3290 3680 4400 5114 1910 2380 2900 3300 3800 4215 5070

0.94 1.17 1.43 1.69 2.22 2.79 3.26 — 0.50 0.71 0.92 1.16 1.42 1.68 2.22 2.80 3.23 — 0.5 0.7 0.94 1.17 1.42 1.67 2.23 — — 0.49 0.70 0.93 1.17 1.40 1.66 2.17 — 0.49 0.71 0.91 1.15 1.38 1.62 —

2400 2750 3080 3390 4050 4628 5020 — 1640 2040 2470 2800 3130 3450 4070 4650 5100 — 1800 2260 2630 3060 3415 3800 4450 — — 2015 2500 2920 3360 3800 4215 5030 — 2200 2710 3280 3740 4270 4725 —

1.28 1.62 1.97 2.35 — — — — 0.67 0.97 1.26 1.60 1.96 2.32 — — — — 0.67 0.96 1.28 1.61 1.97 — — — — 0.66 0.94 1.27 1.61 1.94 — — — 0.66 0.95 1.25 1.58 — — —

3530 4020 4500 4990 — — — — 2500 3000 3590 4080 4540 5000 — — — — 2590 3220 3770 4330 4820 — — — — 2810 3500 4070 4660 5220 — — — 3030 3720 4400 5030 — — —

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 603

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Loose Tube Fiber Optic Cable Applications Multi-purpose Outdoor — Aerial Lashed, Duct, Direct Buried Constructions Dielectric, Armored, Double Armored Fiber Count 2 to 432 fibers in Color-coded Buffer Tubes Fiber Types Singlemode / Multimode Options Gel-Filled Core / Steel Central Member / Copper Pair(s) Other versions Central / Heavy Duty / Indoor-Outdoor Performance ANSI/ICEA, IEC, RUS, Telcordia GR-20 Mechanical Specifications Installation [+] Maximum installation load 600 lbf (2670 N) [+] Maximum operation load 180 lbf (800 N) Temperature Range [+] Shipping and Storage -40°F to +167°F (-40°C to +75°C) [+] Installation -22°F to +140°F (-30°C to +60°C) [+] Operation -40°F to +158°F (-40°C to +70°C)

Item #

Fiber Count

Dielectric (Non-Armored) LT-DNA-1 2 to 60 LT-DNA-2 62 to 72 LT-DNA-3 74 to 84 LT-DNA-4 86 to 96 LT-DNA-5 98 to 108 LT-DNA-6 110 to 120 LT-DNA-7 122 to 132 LT-DNA-8 134 to 216 LT-DNA-9 218 to 264 LT-DNA-10 266 to 288 LT-DNA-11 290 to 432*

Number of Buffer Tubes

Diameter (in)

Diameter (mm)

5 6 7 8 9 10 11 18 22 24 18

0.42 0.45 0.49 0.53 0.56 0.60 0.63 0.67 0.74 0.77 0.73

10.6 11.5 12.3 13.4 14.2 15.1 16.1 16.9 18.9 19.6 18.6

Approximate Approximate Cable Cable Weight Weight /MFT /km (lb) (kg) 53 63 72 82 90 99 109 126 153 167 153

79 94 107 122 134 147 162 187 228 248 228

Bend Radius Load (in)

Bend Radius Load (cm)

Bend Radius No Load (in)

Bend Radius No Load (cm)

8 9 10 11 11 12 13 13 15 15 15

21 23 25 27 28 30 32 34 38 39 37

4 5 5 5 6 6 6 7 7 8 7

11 11 12 13 14 15 16 17 19 20 19

*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

604


Return to Table of Contents

Loose Tube Fiber Optic Cable Item #

Fiber Count

Number of Buffer Tubes

Single Jacket Armored LT-SJA-1 2 to 60 5 LT-SJA-2 62 to 72 6 LT-SJA-3 74 to 84 7 LT-SJA-4 86 to 96 8 LT-SJA-5 98 to 108 9 LT-SJA-6 110 to 120 10 LT-SJA-7 122 to 132 11 LT-SJA-8 134 to 216 18 LT-SJA-9 218 to 264 22 LT-SJA-10 266 to 288 24 LT-SJA-11 290 to 432* 18 Double Jacket Armored LT-DJA-1 2 to 60 5 LT-DJA-2 62 to 72 6 LT-DJA-3 74 to 84 7 LT-DJA-4 86 to 96 8 LT-DJA-5 98 to 108 9 LT-DJA-6 110 to 120 10 LT-DJA-7 122 to 132 11 LT-DJA-8 134 to 216 18 LT-DJA-9 218 to 264 22 LT-DJA-10 266 to 288 24 LT-DJA-11 290 to 432* 18 Dielectric Double Jacket (Non-Armored) LT-DDJ-1 2 to 60 5 LT-DDJ-2 62 to 72 6 LT-DDJ-3 74 to 84 7 LT-DDJ-4 86 to 96 8 LT-DDJ-5 98 to 108 9 LT-DDJ-6 110 to 120 10 LT-DDJ-7 122 to 132 11 LT-DDJ-8 134 to 216 18 LT-DDJ-9 218 to 264 22 LT-DDJ-10 266 to 288 24 LT-DDJ-11 290 to 432* 18

Diameter (in)

Diameter (mm)

Approximate Approximate Cable Cable Weight Weight /MFT /km (lb) (kg)

Bend Radius Load (in)

Bend Radius Load (cm)

Bend Radius No Load (in)

Bend Radius No Load (cm)

0.48 0.51 0.55 0.59 0.62 0.66 0.69 0.73 0.81 0.84 0.80

12.2 13.0 14.0 15.0 15.8 16.8 17.6 18.6 20.6 21.4 20.3

98 109 122 135 146 161 171 195 231 242 225

146 162 182 201 218 240 255 291 344 360 225

10 10 11 12 12 13 14 15 16 17 16

24 26 28 30 32 34 35 37 41 43 41

7 8 8 9 9 10 10 11 12 13 12

18 20 21 23 24 25 26 28 31 32 31

0.54 0.57 0.61 0.65 0.68 0.72 0.75 0.79 0.87 0.90 0.87

13.8 14.5 15.5 16.6 17.3 18.3 19.1 20.1 22.1 22.9 22.1

118 138 153 170 182 201 212 239 283 295 279

175 205 228 253 272 300 315 356 421 439 415

11 11 12 13 14 14 15 16 17 18 17

28 29 31 33 35 37 38 40 44 46 44

8 9 9 10 10 11 11 12 13 14 13

21 22 23 25 26 28 29 30 33 34 33

0.48 0.51 0.55 0.59 0.62 0.66 0.69 0.73 0.80 0.83 0.79

12.1 13.0 13.9 15.0 15.7 16.7 17.6 18.4 20.4 21.2 20.1

68 83 91 103 111 123 132 149 184 192 182

101 124 136 153 165 182 196 221 274 286 271

10 10 11 12 12 13 14 15 16 17 16

24 26 28 30 31 33 35 37 41 42 41

5 5 5 6 6 7 7 7 8 8 8

12 13 14 15 16 17 18 18 20 21 20

*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 604

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Loose Tube Fiber Optic Cable Item #

Fiber Count

Double Jacket Double Armored LT-DJDA-1 2 to 60 LT-DJDA-2 62 to 72 LT-DJDA-3 74 to 84 LT-DJDA-4 86 to 96 LT-DJDA-5 98 to 108 LT-DJDA-6 110 to 120 LT-DJDA-7 122 to 132 LT-DJDA-8 134 to 216 LT-DJDA-9 218 to 264 LT-DJDA-10 266 to 288 LT-DJDA-11 290 to 432* Triple Jacket Double Armored LT-TJDA-1 2 to 60 LT-TJDA-2 62 to 72 LT-TJDA-3 74 to 84 LT-TJDA-4 86 to 96 LT-TJDA-5 98 to 108 LT-TJDA-6 110 to 120 LT-TJDA-7 122 to 132 LT-TJDA-8 134 to 216 LT-TJDA-9 218 to 264 LT-TJDA-10 266 to 288 LT-TJDA-11 290 to 432*

Number of Buffer Tubes

Diameter (in)

Diameter (mm)

Approximate Approximate Cable Cable Weight Weight /MFT /km (lb) (kg)

5 6 7 8 9 10 11 18 22 24 18

0.67 0.70 0.74 0.78 0.81 0.85 0.88 0.92 1.00 1.03 1.01

17.1 17.8 18.8 19.9 20.6 21.6 22.4 23.4 25.5 26.2 25.7

205 232 253 274 288 315 330 359 414 429 416

5 6 7 8 9 10 11 18 22 24 18

0.73 0.76 0.80 0.84 0.87 0.91 0.94 0.98 1.06 1.09 1.08

18.6 19.4 20.4 21.4 22.1 23.2 23.9 24.9 27.0 27.7 27.4

235 270 292 317 333 359 377 412 468 488 486

Bend Radius Load (in)

Bend Radius Load (cm)

Bend Radius No Load (in)

Bend Radius No Load (cm)

306 346 377 408 428 468 492 535 616 638 619

13 14 15 16 16 17 18 18 20 21 20

34 36 38 40 41 43 45 47 50 52 51

10 11 11 12 12 13 13 14 15 15 15

26 27 28 30 31 32 34 35 38 39 38

350 402 434 472 495 534 561 613 696 727 723

15 15 16 17 17 18 19 20 21 22 22

37 39 41 43 44 46 48 50 54 55 55

11 11 12 13 13 14 14 15 16 16 16

28 29 31 32 33 35 36 37 40 42 42

*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice.

604


Return to Table of Contents

Duct Duct Materials The duct shall be extruded from either medium density polyethylene type II, class C, category 5, or high density polyethylene type III, class C, category 5 as outlined in ASTM D1248. Duct Dimensions The following duct dimensions are recommended, however, AWG will provide duct to customer's required dimensions when specified.

Item #

Conduit Size

Conduit Outer Diameter

Minimum Wall Thickness

Bending Radius

1-1/4 1-1/2 2

1-1/4 1-1/2 2

1.66 1.90 2.38

100 115 145

18 21 26

Conductor Maximum Weight Cable /MFT Diameter (lb) (in) 220 280 440

1.05 1.20 1.5

Typical Unjacketed Conductor Size

Elongation

#2 through 2/0 1/0 through 250 4/0 through 500

400 400 400

Melt Brittleness Brittleness Index Temp. Temp. Maximum Maximum Maximum Medium High (C°) (C°) .4 .4 .4

-45 -45 -45

-75 -75 -75

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

605


Return to Table of Contents

Control Cable FR-XLPE Insulated Conductors CPE Jacket, 600V Applications As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Construction Stranded uncoated copper conductors, 30 mils FR-XLPE flame-retardant cross-linked polyethylene insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, CPE jacket overall, surface printed. Standards • Listed by UL as Type TC per Standard 1277 for Tray Cables. • Cables UL listed for Direct Burial. • Individual conductors pass UL VW-1 flame test. • Individual conductors UL listed as Type XHHW-2. • Overall jacket UL listed as Sunlight Resistant. • Cables with grounding conductor UL listed for Open Wiring. • Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test. • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test. • Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables. • Color Code ICEA Method 4. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding: ICEA Method 1, Table E-1 • EPR Insulation • PVC, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

503


Return to Table of Contents

Control Cable FR-XLPE Insulated Conductors CPE Jacket, 600V Item #

Number of Conductors

Size AWG

Number of Nominal Nominal Nominal Nominal Nominal Strands Insulation Insulation Jacket Jacket Cable Thickness Thickness Thickness Thickness O.D. (in) (mm) (in) (mm) (in)

Nominal Cable O.D. (mm)

Copper Weight /MFT (lb)

Copper Weight /km (kg)

Approx. Weight /MFT (lb)

Approx. Weight /km (kg)

14-R-CPE-2-FLAT 2 FLAT 14-R-CPE-2 2 14-R-CPE-3 3 14-R-CPE-4 4 14-R-CPE-5 5 14-R-CPE-7 7 14-R-CPE-9 9 14-R-CPE-12 12 14-R-CPE-19 19 14-R-CPE-25 25 14-R-CPE-30 30 14-R-CPE-37 37

14 14 14 14 14 14 14 14 14 14 14 14

7 7 7 7 7 7 7 7 7 7 7 7

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03

.235x.370 0.365 0.390 0.425 0.465 0.590 0.620 0.680 0.800 0.985 1.050 1.130

5.97x9.40 9.270 9.910 10.800 11.810 14.990 15.750 17.270 20.320 25.020 26.670 28.700

25 25 40 53 66 93 119 159 252 323 387 490

37 37 59 79 99 138 177 237 375 481 571 729

62 73 93 116 140 176 245 302 460 641 740 888

92 109 138 173 208 262 365 449 685 954 1101 1322

12-R-CPE-2-FLAT 2 FLAT 12-R-CPE-2 2 12-R-CPE-3+GRND 3+Grnd 12-R-CPE-3 3 12-R-CPE-4 4 12-R-CPE-5 5 12-R-CPE-7 7 12-R-CPE-9 9 12-R-CPE-12 12 12-R-CPE-19 19 12-R-CPE-25 25 12-R-CPE-30 30 12-R-CPE-37 37

12 12 12 12 12 12 12 12 12 12 12 12 12

7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03 2.03

.245x.400 6.22x10.16 0.410 10.410 0.435 11.050 0.435 11.050 0.475 12.070 0.515 13.080 0.595 15.110 0.695 17.650 0.780 19.810 0.930 23.620 1.095 27.810 1.150 29.210 1.240 31.500

40 41 86 65 86 108 150 193 258 403 515 618 741

60 61 128 96 128 160 224 288 385 600 767 920 1103

86 96 143 125 157 191 260 340 429 681 885 1005 1185

128 143 213 186 234 284 387 506 638 1013 1317 1496 1764

10-R-CPE-2-FLAT 2 FLAT 10-R-CPE-2 2 10-R-CPE-3+GRND 3+Grnd 10-R-CPE-3 3 10-R-CPE-4 4 10-R-CPE-5 5 10-R-CPE-7 7 10-R-CPE-9 9 10-R-CPE-12 12

10 10 10 10 10 10 10 10 10

7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.080

1.14 1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03

.290x.480 0.455 0.485 0.485 0.515 0.615 0.670 0.785 0.895

66 67 135 101 135 167 234 295 402

98 100 200 150 200 249 349 440 598

114 130 201 173 236 287 371 479 644

170 193 299 257 351 427 552 713 958

7.37x12.19 11.560 12.320 12.320 13.080 15.620 17.020 19.940 22.730

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 503

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Control Cable FR-XLPE Insulated Conductors Copper Shield, CPE Jacket, 600V Applications Control or signal cable for important circuits in industrial plants and station control cable for electric utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600V; recommended for operation at 90°C maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL requirements. Construction Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene rubber (FR-EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket overall, surface printed. Standards • TC Type Tray Cable per Article 340 of the NEC. • Individual conductors pass UL Standard 44 and the VW-1 vertical flame test. • Individual conductors approved as Type XHHW. •. Cables Pass IEEE-383 ribbon burner flame test. • Overall jacket approved as Sunlight Resistant. • Cables meet requirements of ICEA S-73-532, NEMA WC57 for control cables. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding: ICEA Method 1, Table E-1 • EPR Insulation • PVC, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

505


Return to Table of Contents

Control Cable FR-XLPE Insulated Conductors Copper Shield, CPE Jacket, 600V Item #

Number of Conductors

Conductor Stranding

Conductor Size AWG

Overall mils

Overall Diameter (in)

Approx. Cable Weight /MFT (lb)

14-402SH 14-403SH 14-404SH 14-405SH 14-406SH 14-407SH 14-408SH 14-409SH 14-412SH 14-414SH 14-415SH 14-416SH 14-418SH 14-419SH 14-420SH 14-425SH 14-427SH 14-429SH 14-431SH 14-432SH 14-437SH

2 3 4 5 6 7 8 9 12 14 15 16 18 19 20 25 27 29 31 32 37

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14

45 45 45 45 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80

0.40 0.42 0.45 0.49 0.53 0.60 0.70 N/A 0.89 0.96 1.04 1.05 1.07 1.09 1.10 1.22 1.25 1.26 1.31 1.34 1.39

120 145 180 230 275 275 305 N/A 435 530 565 575 665 665 720 905 905 960 1090 1090 1165

12-452SH 12-453SH 12-454SH 12-455SH 12-456SH 12-457SH 12-458SH 12-462SH 12-464SH 12-465SH 12-466SH 12-468SH 12-469SH 12-470SH 12-475SH 12-477SH 12-479SH 12-481SH 12-482SH 12-487SH

2 3 4 5 6 7 8 12 14 15 16 18 19 20 25 27 29 31 32 37

12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

45 45 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80

0.49 0.54 0.62 0.67 0.70 0.73 0.86 0.95 1.04 1.20 1.22 1.25 1.25 1.31 1.39 1.41 1.42 1.44 1.47 1.53

155 185 245 295 340 340 395 610 690 770 780 865 865 940 1175 1200 1270 1425 1425 1545

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 505

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Control Cable FR-XLPE Insulated Conductors Copper Shield, CPE Jacket, 600V Item #

Number of Conductors

Conductor Stranding

Conductor Size AWG

Overall mils

Overall Diameter (in)

Approx. Cable Weight /MFT (lb)

10-502SH

2

10

7

45

0.52

190

10-503SH 10-504SH 10-505SH 10-506SH 10-507SH 10-508SH 10-512SH 10-514SH 10-515SH 10-516SH 10-518SH 10-519SH 10-520SH 10-525SH 10-527SH 10-529SH 10-531SH 10-532SH 10-537SH

3 4 5 6 7 8 12 14 15 16 18 19 20 25 27 29 31 32 37

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80 80

0.62 0.68 0.73 0.80 0.85 1.05 1.10 1.14 1.20 1.24 1.27 1.27 1.34 1.48 1.52 1.54 1.60 1.63 1.70

255 320 370 440 450 755 810 920 995 1020 1140 1155 1255 1600 1625 1730 1950 1950 2120

*Part numbers are for CPE jacketed cables only

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

505


Return to Table of Contents

Control Cable FR-EPR Insulated Conductors CPE Jacket, 600V Applications As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Construction Stranded uncoated copper conductors, 30 mils Flame Retardant Ethylene Propylene Rubber (FREPR) insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, CPE jacket overall, surface printed. Standards • Listed by UL as Type TC per Standard 1277 for Tray Cables. • Cables UL listed for Direct Burial. • Individual conductors pass UL VW-1 flame test. • Individual conductors UL listed as Type XHHW-2. • Overall jacket UL listed as Sunlight Resistant. • Cables with grounding conductor UL listed for Open Wiring. • Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test. • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test. • Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding ICEAA Method 1, Table E-1 • FRXLP Insulation • PVC, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

511


Return to Table of Contents

Control Cable FR-EPR Insulated Conductors CPE Jacket, 600V Item #

Size Conductor Ground Nominal Nominal Nominal Nominal Nominal AWG Strand Wire Insulation Insulation Jacket Jacket Cable Size Thickness Thickness Thickness Thickness O.D. AWG (in) (mm) (in) (mm) (in)

Nominal Cable O.D. (mm)

Copper Weight /MFT (lb)

Copper Weight /km (kg)

Approx. Weight /MFT (lb)

Approx. Weight /km (kg)

14-E-CPE-2-FLAT 2 FLAT 14-E-CPE-3 3 14-E-CPE-4 4 14-E-CPE-5 5 14-E-CPE-7 7 14-E-CPE-9 9 14-E-CPE-12 12 14-E-CPE-19 19 14-E-CPE-25 25 14-E-CPE-30 30 14-E-CPE-37 37

14 14 14 14 14 14 14 14 14 14 14

7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03

.365x.230 0.390 0.425 0.465 0.505 0.620 0.700 0.815 0.935 1.030 1.110

9.30x5.80 9.910 10.800 11.810 12.830 15.750 17.780 20.700 23.750 26.160 28.190

26 39 53 66 92 118 158 250 323 387 466

38 59 78 98 137 176 235 372 481 576 694

61 92 115 139 173 240 301 468 624 747 875

91 137 171 207 257 357 448 696 929 1112 1302

12-E-CPE-2-FLAT 2 FLAT 12-E-CPE-2 2 12-E-CPE-3 3 12-E-CPE-4 4 12-E-CPE-5 5 12-E-CPE-7 7 12-E-CPE-9 9 12-E-CPE-12 12 12-E-CPE-19 19 12-E-CPE-25 25 12-E-CPE-30 30 12-E-CPE-37 37

12 12 12 12 12 12 12 12 12 12 12 12

7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03 2.03

.400x.245 10.20x6.20 0.410 10.410 0.435 11.050 0.475 12.070 0.520 13.210 0.595 15.110 0.695 17.650 0.765 19.430 0.940 23.880 1.095 27.810 1.150 29.210 1.240 31.500

42 42 64 85 106 149 191 247 391 515 618 762

63 63 95 127 158 221 285 368 582 767 920 1134

82 94 124 157 191 268 337 428 688 854 1002 1240

122 140 185 234 284 399 502 637 1024 1271 1491 1845

10-E-CPE-2-FLAT 2 FLAT 10-E-CPE-2 2 10-E-CPE-3 3 10-E-CPE-4 4 10-E-CPE-5 5 10-E-CPE-7 7 10-E-CPE-9 9 10-E-CPE-12 12

10 10 10 10 10 10 10 10

7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.080

1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03

.445x.270 0.455 0.485 0.560 0.615 0.670 0.760 0.950

64 65 100 134 167 234 295 402

95 97 150 199 249 349 440 598

113 128 172 234 284 381 464 651

168 190 256 348 423 567 691 969

11.30x6.90 11.560 12.320 14.220 15.620 17.020 19.300 22.990

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 511

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Control Cable FR-EPR Insulated Conductors Copper Shield, CPE Jacket, 600V Applications Control or signal cable for important circuits in industrial plants and station control cable for electric utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600V; recommended for operation at 90°C maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL requirements. Construction Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene rubber (EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 colorcoded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket overall, surface printed. Standards • TC Type Tray Cable per Article 340 of the NEC. • Individual conductors pass UL Standard 44 and the VW-1 vertical flame test. • Individual conductors approved as Type XHHW. • Cables Pass IEEE-383 ribbon burner flame test. • Overall jacket approved as Sunlight Resistant. • Cables meet requirements of ICEA S-73-532/NEMA WC57 for control cables. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding: ICEA Method 1, Table E-1 • FRXLP Insulation • PVC, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

513


Return to Table of Contents

Control Cable FR-EPR Insulated Conductors Copper Shield, CPE Jacket, 600V Item #

Number of Conductors

Conductor Size AWG

Conductor Stranding

Copper Shield Thickness (in)

Copper Shield Thickness (mm)

Nominal Jacket Thickness (in)

Nominal Jacket Thickness (mm)

Nominal Cable O.D. (in)

Nominal Cable O.D. (mm)

Approx. Cable Weight /MFT (lb)

Approx. Cable Weight /Km (kg)

14-402ESH 14-403ESH 14-404ESH 14-405ESH 14-407ESH 14-409ESH 14-412ESH

2 3 4 5 7 9 12

14 14 14 14 14 14 14

7 7 7 7 7 7 7

.005 .005 .005 .005 .005 .005 .005

0.13 0.13 0.13 0.13 0.13 0.13 0.13

.045 .045 .045 .060 .060 .060 .060

1.1 1.1 1.1 1.5 1.5 1.5 1.5

0.445 0.470 0.505 0.580 0.620 0.705 0.785

11.3 11.9 12.8 14.7 15.7 17.9 19.9

109 132 155 207 246 311 393

162 196 231 308 366 463 585

12-452ESH 12-453ESH 12-454ESH 12-455ESH 12-457ESH 12-459ESH 12-462ESH

2 3 4 5 7 9 12

12 12 12 12 12 12 12

7 7 7 7 7 7 7

.005 .005 .005 .005 .005 .005 .005

0.13 0.13 0.13 0.13 0.13 0.13 0.13

.045 .045 .060 .060 .060 .060 .080

1.1 1.1 1.5 1.5 1.5 1.5 2.0

0.485 0.510 0.585 0.630 0.675 0.775 0.905

12.3 13.0 14.9 16.0 17.1 19.7 23.0

137 163 225 259 322 409 552

204 243 335 385 479 609 821

10-502ESH 10-503ESH 10-504ESH 10-505ESH 10-507ESH 10-509ESH 10-512ESH

2 3 4 5 7 9 12

10 10 10 10 10 10 10

7 7 7 7 7 7 7

.005 .005 .005 .005 .005 .005 .005

0.13 0.13 0.13 0.13 0.13 0.13 0.13

.045 .060 .060 .060 .060 .080 .080

1.1 1.5 1.5 1.5 1.5 2.0 2.0

0.535 0.595 0.640 0.695 0.750 0.910 1.010

13.6 15.1 16.3 17.7 19.1 23.1 25.7

179 234 289 340 442 590 748

266 348 430 506 658 878 1113

08-552ESH 08-553ESH 08-554ESH

2 3 4

8 8 8

7 7 7

.005 .005 .005

0.13 0.13 0.13

.060 .060 .060

1.5 1.5 1.5

0.695 0.735 0.795

17.7 18.7 20.2

288 365 444

429 543 661

06-602ESH 06-603ESH 06-603ESH

2 3 4

6 6 6

7 7 7

.005 .005 .005

0.13 0.13 0.13

.060 .060 .080

1.5 1.5 2.0

0.775 0.820 0.935

19.7 20.8 23.4

378 494 645

562 735 956

04-502ESH 04-503ESH 04-554ESH

2 3 4

4 4 4

7 7 7

.005 .005 .005

0.13 0.13 0.13

.080 .080 .080

2.0 2.0 2.0

0.915 0.965 1.055

23.2 24.5 26.8

550 722 903

818 1074 1344

02-503ESH 02-554ESH 02-554ESH

2 3 4

2 2 2

7 7 7

.005 .005 .005

0.13 0.13 0.13

.080 .080 .080

2.0 2.0 2.0

1.035 1.100 1.200

26.3 27.9 30.5

758 1007 1288

1128 1498 1917

01-503ESH 01-554ESH

2 3

1 1

19 19

.005 .005

0.13 0.13

.080 .080

2.0 2.0

1.230 1.350

31.2 34.3

1236 1564

1839 2327

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 513

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

20/10 Control Cable PE/PVC Insulated Conductors PVC Jacket, 600V Applications Standard general purpose control cable for important control circuits in industrial plants and station control cable for utilities. Suitable for operation and interconnection of protective devices; rated circuit voltage 600V, recommended for operation at 75°C maximum continuous conductor temperature. For Non NEC Application Cables may be installed in open air, in ducts or conduit, or in tray or trough and direct burial. For metering installations where insulated conductors are subject to sunlight degradation, these cables can be jacketed with special UV-resistant compounds. Construction Stranded uncoated copper conductors, 20 mils black high molecular weight polyethylene insulation, 10 mils full color coded PVC Jacket over each insulated conductor, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, polyester tape over assembly, PVC jacket overall, surface printed. Standards Physical and electrical tests in accordance with appropriate sections of ICEA S-73-532, NEMA WC57. Notes • Single conductor 20 mils high molecular weight polyethylene insulation and 10 mils polyvinyl chloride jacket, 600V. • Color coding is ICEA Appendix E Method 1 Table E-1. Options • Flexible stranded conductors • Tin-coated copper conductors per ASTM B33 • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

Item #

14-CTB-2 14-CTB-3 14-CTB-4 14-CTB-5 14-CTB-7 14-CTB-9 14-CTB-12 14-CTB-15 14-CTB-19 14-CTB-25 14-CTB-30 14-CTB-37

Number of Conductors

Conductor Size AWG

Conductor Stranding

Nominal Jacket Thickness (in)

Nominal Jacket Thickness (mm)

Nominal Cable O.D. (in)

Nominal Cable O.D. (mm)

2 3 4 5 7 9 12 15 19 25 30 37

14 14 14 14 14 14 14 14 14 14 14 14

7 7 7 7 7 7 7 7 7 7 7 7

.045 .045 .045 .045 .045 .060 .060 .060 .060 .080 .080 .080

1.1 1.1 1.1 1.1 1.1 1.5 1.5 1.5 1.5 2.0 2.0 2.0

.235 x .375 0.400 0.435 0.475 0.515 0.640 0.710 0.785 0.825 1.030 1.065 1.150

5.97 x 9.53 10.2 11.0 12.1 13.1 16.3 18.0 19.9 21.0 26.2 27.1 29.2

Approximate Approximate Cable Weight Cable Weight /MFT /Km (lb) (kg) 63 95 117 132 174 238 305 370 453 624 693 832

93 141 173 195 258 352 451 548 670 924 1026 1231

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

514


Return to Table of Contents

20/10 Control Cable PE/PVC Insulated Conductors PVC Jacket, 600V Item #

Number of Conductors

Conductor Size AWG

Conductor Stranding

Nominal Jacket Thickness (in)

Nominal Jacket Thickness (mm)

Nominal Cable O.D. (in)

Nominal Cable O.D. (mm)

Approximate Approximate Cable Weight Cable Weight /MFT /Km (lb) (kg)

12-CTB-2 12-CTB-3 12-CTB-4 12-CTB-5 12-CTB-7 12-CTB-9 12-CTB-12 12-CTB-15 12-CTB-19 12-CTB-25 12-CTB-30 12-CTB-37

2 3 4 5 7 9 12 15 19 25 30 37

12 12 12 12 12 12 12 12 12 12 12 12

7 7 7 7 7 7 7 7 7 7 7 7

.045 .045 .045 .045 .060 .060 .060 .080 .080 .080 .080 .080

1.1 1.1 1.1 1.1 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.0

.255 x .415 0.445 0.485 0.560 0.610 0.715 0.795 0.920 0.970 1.150 1.195 1.290

6.48 x 10.50 11.3 12.3 14.2 15.5 18.2 20.2 23.4 24.6 29.2 30.4 32.8

85 126 158 200 259 328 423 554 675 865 1020 1234

126 186 234 296 383 485 626 820 999 1280 1510 1826

10-CTB-2 10-CTB-3 10-CTB-4 10-CTB-5 10-CTB-7 10-CTB-9 10-CTB-12 10-CTB-15 10-CTB-19 10-CTB-25 10-CTB-30 10-CTB-37

2 3 4 5 7 9 12 15 19 25 30 37

10 10 10 10 10 10 10 10 10 10 10 10

7 7 7 7 7 7 7 7 7 7 7 7

.045 .045 .060 .060 .060 .060 .080 .080 .080 .080 .080 .080

1.1 1.1 1.5 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.0 2.0

.280 x .460 0.495 0.580 0.625 0.680 0.805 0.935 1.035 1.090 1.300 1.350 1.460

7.11 x 11.7 12.6 14.7 15.9 17.3 20.4 23.7 26.3 27.7 33.0 34.3 37.1

116 170 235 274 364 462 638 780 958 1245 1464 1778

171 252 348 406 539 684 944 1154 1418 1843 2167 2631

9-CTB-2 9-CTB-3 9-CTB-4 9-CTB-5 9-CTB-7 9-CTB-9 9-CTB-12 9-CTB-15 9-CTB-19 9-CTB-25 9-CTB-30 9-CTB-37

2 3 4 5 7 9 12 15 19 25 30 37

9 9 9 9 9 9 9 9 9 9 9 9

7 7 7 7 7 7 7 7 7 7 7 7

.045 .045 .060 .060 .060 .060 .080 .080 .080 .080 .080 .080

1.1 1.1 1.5 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.0 2.0

.290 x .490 0.520 0.600 0.660 0.720 0.845 0.985 1.095 1.150 1.380 1.430 1.545

7.37 x 12.4 13.2 15.2 16.8 18.3 21.5 25.0 27.8 29.2 35.1 36.3 39.2

132 188 258 313 418 530 731 896 1100 1433 1688 2050

195 278 382 463 619 784 1082 1326 1628 2121 2499 3034

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 514

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

20/10 Control Cable PE/PVC Insulated Conductors Shielded, PVC Jacket, 600V Applications Standard general purpose control cable for important control circuits in industrial plants and station control cable for utilities. Suitable for operation and interconnection of protective devices; rated circuit voltage 600V, recommended for operation at 75°C maximum continuous conductor temperature. For Non NEC Application Cables may be installed in open air, in ducts or conduit, or in tray or trough and direct burial. For metering installations where insulated conductors are exposed to sunlight degradations, these cables can be jacketed with special UV-resistant compounds. Construction Stranded uncoated copper conductors, 20 mils black high molecular weight polyethylene insulation, 10 mils full color coded PVC Jacket over each insulated conductor, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, polyester tape over assembly, copper tape shield, PVC jacket overall, surface printed. Standards Physical and electrical tests in accordance with appropriate sections of ICEA S-73-532, NEMA WC57. Notes • Single conductor 20 mils high molecular weight polyethylene insulation and 10 mils polyvinyl chloride jacket, 600V. • Color coding is ICEA Appendix E Method 1 Table E-1. Options • Flexible stranded conductors • Tin-coated copper conductors per ASTM B33 • Copper braid shield • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

Item #

Number of Conductors

Conductor Size AWG

Conductor Stranding

Copper Shield Thickness (in)

Copper Shield Thickness (mm)

Nominal Jacket Thickness (in)

Nominal Jacket Thickness (mm)

Nominal Cable O.D. (in)

Nominal Cable O.D. (mm)

Approx. Cable Weight /MFT (lb)

Approx. Cable Weight /Km (kg)

10-CTB-2-S 10-CTB-3-S 10-CTB-4-S

2 3 4

10 10 10

7 7 7

.005 .005 .005

0.1 0.1 0.1

.060 .060 .060

1.5 1.5 1.5

0.600 0.640 0.695

15.2 16.3 17.7

233 285 333

345 423 493

9-CTB-3-S 9-CTB-4-S 9-CTB-5-S

3 4 5

9 9 9

7 7 7

.005 .005 .005

0.1 0.1 0.1

.060 .060 .060

1.5 1.5 1.5

0.620 0.670 0.725

15.7 17.0 18.4

258 318 377

382 471 558

8-CTB-3-S 8-CTB-4-S

3 4

8 8

7 7

.005 .005

0.1 0.1

.060 .080

1.5 2.0

0.805 0.920

20.4 23.4

391 511

579 756

6-CTB-3-S 6-CTB-4-S

3 4

6 6

7 7

.005 .005

0.1 0.1

.080 .080

2.0 2.0

0.980 1.065

24.9 27.1

585 722

866 1069

4-CTB-3-S 4-CTB-4-S

3 4

4 4

7 7

.005 .005

0.1 0.1

.080 .080

2.0 2.0

1.090 1.190

27.7 30.2

771 982

1141 1453

2-CTB-3-S 2-CTB-4-S

3 4

2 2

7 7

.005 .005

0.1 0.1

.080 .080

2.0 2.0

1.225 1.345

31.1 34.2

1076 1369

1592 2026

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

515


Return to Table of Contents

30/15 Control Cable PE/PVC Insulated Conductors PVC Jacket, 1000V Applications Standard general purpose control cable for important control circuits in industrial plants and station control cable for utilities. Suitable for operation and interconnection of protective devices; rated circuit voltage 1000V, recommended for operation at 75°C maximum continuous conductor temperature. For Non NEC application cables may be installed in open air, in ducts or conduit, or in tray or trough and direct burial. Construction Stranded uncoated copper conductors, 30 mils black high molecular weight polyethylene insulation, 15 mils full color coded PVC Jacket over each insulated conductor, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, polyester tape over assembly, PVC jacket overall, surface printed. Standards Physical and electrical tests in accordance with appropriate sections of ICEA S-73-532, NEMA WC57. Notes ● Single conductor 30 mils high molecular weight polyethylene insulation and 15 mils polyvinyl chloride jacket, 1000V. ● Single conductor cable not recommended for direct earth burial. ● Color coding is ICEA Method 1, Table E1. ● Cables available with either a Cu tape shield or longitudinally corrugated shield upon request.

Item #

14-CTC-1 14-CTC-2 14-CTC-3 14-CTC-4 14-CTC-5 14-CTC-6 14-CTC-7 14-CTC-8 14-CTC-9 14-CTC-10 14-CTC-11 14-CTC-12 14-CTC-13 14-CTC-14 14-CTC-15 14-CTC-16 14-CTC-17 14-CTC-18 14-CTC-19 14-CTC-20 14-CTC-23 14-CTC-25 14-CTC-27 14-CTC-29 14-CTC-31 14-CTC-32 14-CTC-37

Number of Conductors

Size AWG

Number of Strands

Outer PVC Jacket Thickness (mil)

Nominal Diameter (in)

Weight /MFT (lb)

1 2 Flat 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 23 25 27 29 31 32 37

14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

N/A 45 45 45 60 60 60 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

0.20 .26 x .43 0.46 0.50 0.58 0.63 0.63 0.68 0.73 0.80 0.80 0.82 0.88 0.91 0.95 0.95 1.00 1.00 1.00 1.06 1.11 1.12 1.20 1.21 1.26 1.29 1.34

25 75 105 140 180 205 220 270 295 330 360 380 420 445 485 500 530 550 575 610 680 735 780 835 885 910 1025

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

516


Return to Table of Contents

30/15 Control Cable PE/PVC Insulated Conductors PVC Jacket, 1000V Item #

12-CTC-1 12-CTC-2 12-CTC-3 12-CTC-4 12-CTC-5 12-CTC-6 12-CTC-7 12-CTC-8 12-CTC-9 12-CTC-10 12-CTC-11 12-CTC-12 12-CTC-13 12-CTC-14 12-CTC-15 12-CTC-16 12-CTC-17 12-CTC-18 12-CTC-19 12-CTC-20 12-CTC-23 12-CTC-25 12-CTC-27 12-CTC-29 12-CTC-31 12-CTC-32 12-CTC-37

Number of Conductors

Size AWG

Number of Strands

Outer PVC Jacket Thickness (mil)

Nominal Diameter (in)

Weight /MFT (lb)

1 2 Flat 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 23 25 27 29 31 32 37

12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

N/A 45 45 60 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

0.22 .28 x .47 0.50 0.58 0.63 0.69 0.69 0.75 0.80 0.92 0.92 0.95 0.96 1.00 1.05 1.05 1.10 1.10 1.10 1.16 1.22 1.29 1.32 1.34 1.39 1.42 1.48

35 95 145 190 240 275 290 340 390 470 485 515 550 580 645 660 715 730 745 810 915 1025 1085 1150 1225 1275 1415

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com 516

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

30/15 Control Cable PE/PVC Insulated Conductors PVC Jacket, 1000V Item #

10-CTC-1 10-CTC-2 10-CTC-3 10-CTC-4 10-CTC-5 10-CTC-6 10-CTC-7 10-CTC-8 10-CTC-9 10-CTC-10 10-CTC-11 10-CTC-12 10-CTC-13 10-CTC-14 10-CTC-15 10-CTC-16 10-CTC-17 10-CTC-18 10-CTC-19 10-CTC-20 10-CTC-23 10-CTC-25 10-CTC-27 10-CTC-29 10-CTC-31 10-CTC-32 10-CTC-37

Number of Conductors

Size AWG

Number of Strands

Outer PVC Jacket Thickness (mil)

Nominal Diameter (in)

Weight /MFT (lb

1 2 Flat 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 23 25 27 29 31 32 37

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

N/A 45 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

0.24 .31 x .52 0.59 0.64 0.70 0.76 0.76 0.87 0.93 1.02 1.02 1.05 1.07 1.11 1.17 1.17 1.23 1.23 1.23 1.30 1.36 1.44 1.48 1.49 1.56 1.59 1.67

45 130 205 260 310 370 400 465 560 605 660 700 755 800 880 910 985 1010 1040 1150 1310 1415 1500 1595 1705 1735 1980

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

516


Return to Table of Contents

Terms & Conditions Warranty Price Prices are based on COMEX copper or LME aluminum listed on the quotation. Prices are subject to copper/aluminum adjustment at the time of shipment in the event that COMEX or LME copper exceeds the quoted base in excess of 10%. Cancellation Cancellation after acceptance of an order cannot be made without Seller’s written consent and on such conditions as will indemnify Seller against loss for commitments made and work already complete and/or in process. Special Orders When Special Make Orders are accepted the entire order must be taken. Special Make Orders cannot be cancelled or modified once accepted and cannot be returned. Tolerances Non-Stock & Special Make merchandise is subject to the following tolerances: Total product -0 and Reel lengths +/-10%, or as specified. Exact reel lengths will incur additional charges. Delivery Any shipment schedule is approximate. Seller shall not be liable for any delay in delivery or failure to deliver caused in whole or in part by any reason beyond Seller’s control. Claims Buyer agrees to inspect merchandise for defects and for conformity, and agrees to check material against shipping papers upon unloading at destination. All claims for shortages or defective merchandise must be made by Buyer in writing within seven (7) days of receipt of shipment. Returns Return merchandise must be full reels or cartons, undamaged and in the original unopened package. Credit will be given for returned merchandise only for full reels of undamaged wire if still in the original package. No merchandise may be returned without the written authority of Seller and receipt of Seller’s RMA number. No merchandise may be returned after the expiration of sixty (60) days following the date of shipment. Returns may be subject to a Restocking Fee. Non-Stock & Special Make merchandise will not be considered for return and is not subject to the previous stated return conditions. Refunds No cash refunds. Trade Credit Only. All returns and other proper claims for credit may be applied toward future purchases only or as agreed. Taxes Liability for all taxes imposed by any government authority with respect to the goods herein ordered shall be assumed and paid by Buyer. Modifications Any modification of these Standard Terms and Conditions shall not be binding on Seller unless signed on behalf of Seller by a representative authorized to do so, regardless of whether Seller has commenced shipping of any merchandise ordered hereunder or whether Seller has accepted payments therefore.

Warranty All merchandise ordered will be supplied in accordance with the description on the face of the order acknowledgment and in accordance with applicable specifications and design standards, and will be substantially free from defects in material and workmanship. The Seller’s liability in respect to any defect in or failure of the merchandise supplied, as well as any loss, injury or damage attributable thereto, is limited to the replacement or repair of defects which, under proper use and handling, have been proven to the Seller’s satisfaction to arise solely from faulty design, materials or workmanship, within a period of one (1) year from the date of shipment from the Seller’s factory. Further, the Seller must be notified in writing of the said defect or failure within a period of one (1) year from the date of shipment. The replacement of such merchandise does not include expenses incurred in the installation or use of the material. No merchandise shall be returned to the Seller’s factory or warehouse for credit or replacement before the Seller has officially advised of this transaction. Warranty Limitations This warranty does not cover the repair or replacement of any cable which fails as a result of damage in transit, misuse, neglect, accident, Acts of God, abuse, improper handling, improper storage, excessive stress, faulty or improper or unauthorized installation or repair, negligent maintenance or failure to comply with the written instructions for installation, use or maintenance provided by the Seller. Exclusion of Other Warranties This warranty is in lieu of all other warranties, express or implied, and all other warranties, including but not limited to the implied warranties of merchantability and fitness for a particular purpose, are expressly disclaimed. Limitation of Liability and Limitation of Actions In no event shall Seller be liable for any indirect, incidental, special, punitive or consequential loss, damage or expense (which shall be deemed to include without limitation: any loss of profit or revenue, loss of goodwill, loss claimed by end-user’s customers, or loss of business opportunity) of any nature or kind, however arising, whether in contract, in tort or otherwise, even if Seller is deemed to be aware of the possibility of such damages. Seller’s maximum liability for any claim, loss or damage shall not exceed the purchase price for the cable subject to a claim under any circumstance, even if end-user has claims or is subject to claims in excess of this limitation. Any legal proceeding related to this warranty must be presented within (1) year after the cause of action arises. Sole and Exclusive Remedy This document sets forth the Seller’s sole and exclusive warranty obligation to the Buyer and the Buyer’s sole and exclusive remedy in the event of defective cable. Choice of Law The laws of the State of Florida, without giving effect to its conflicts of law principles, govern all matters arising out of or relating to these Standard Terms and Conditions and all the transactions it contemplates, including, without limitation, its validity, interpretation, construction, performance and enforcement.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

A


Return to Table of Contents

Wire & Cable Methods of Color Coding Used to identify conductors for point-to-point wiring and for circuit diagrams. Color codes are used to establish a standard for use by different manufacturers. The first color code used colored tracers in a solid colored braid. Most control cable color codes are adaptations of this method. Later, for ease and convenience, ink printed versions were developed. Telephone requirements established special color codes. Color Codes (ICEA Methods) ICEA/NEMA Method 1 Colored insulation with contrasting ink tracers as required. Six different insulation colors and four different colored ink tracers are used to provide positive identification through 21 conductors. The same identification sequence is repeated for cables containing more than 21 conductors. ICEA/NEMA Method 2 A neutral colored compound is used with single or double spiral ink tracers as required to provide positive identification through 21 conductors. The identification sequence is repeated for cables containing more than 21 conductors. ICEA/NEMA Method 3 A neutral or single colored insulation compound is surface ink printed with both conductor number and color designation to provide positive identification through 21 conductors. The identification sequence is repeated for colors containing more than 21 conductors. ICEA/NEMA Method 4 A neutral or single colored insulation compound is surface ink printed with conductor number to provide positive conductor identification through 21 conductors. The identification sequence is repeated for cables containing more than 21 conductors.

ICEA/NEMA Method 5 A color coding using braids. Also sometimes specified using colored insulation and contrasting tracers as an extension of Method I to eliminate duplicate conductors. Up to 127 positive conductor coding are available with this method. Usually specified as per: ICEA5-61-402 Table 5-1 or ICEA 5-19-81 Table 5-2. ICEA/NEMA Method 6 A color coding whereby one conductor in each layer is identified by a braid, tape, ridge, stripe or color. ICEA/NEMA Paired Color Code A coding whereby one leg of all pairs is coded white and its mate is coded in accordance with the first 21 conductors of Method 1, omitting white and repeating the sequence as necessary. Telephone Paired Color Code Five colors are paired with each of five mate colors to give 25 identified pairs. The color sequences are repeated for more than 25 pairs using colored binder strings for group identification.

Note: UL and the NEC restrict the use of green and white as colors and stripes. Special color codes are available to meet these requirements. One method is ICEA Method E-2 which is similar to Method 1 and ICEA Method E-4 which is similar to Method 2.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

B


Return to Table of Contents

Wire & Cable Color Coding Charts ICEA Method 1, Table E-1

ICEA Method 1, Table E-2

(Colored compound with tracers)

(Colored compound with tracers)

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Background or Base Color

Tracer Color

Black White Red Green Orange Blue White Red Green Orange Blue Black Red Green Blue Black White Orange Blue Red Orange

– – – – – – Black Black Black Black Black White White White White Red Red Red Red Green Green

*This conductor is in the inside of the assembly.

ICEA Method 2, Table E-1 (Neutral colored compound with tracers)

Conductor Number

1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

First Tracer Color (Wide Tracer) Black White Red Green Orange Blue White Red Green Orange Blue Black Red Green Blue Black White Orange Blue Red Orange

Second Tracer Color (Narrow Tracer) – – – – – – Black Black Black Black Black White White White White Red Red Red Red Green Green

*This conductor is in the inside of the assembly.

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

Background or Base Color Black Red Blue Orange Yellow Brown Red Blue Orange Yellow Brown Black Blue Orange Yellow Brown Black Red Orange Yellow Brown Black Red Blue Yellow Brown Black Red Blue Orange Brown Black Red Blue Orange Yellow

Tracer Color – – – – – – Black Black Black Black Black Red Red Red Red Red Blue Blue Blue Blue Blue Orange Orange Orange Orange Orange Yellow Yellow Yellow Yellow Yellow Brown Brown Brown Brown Brown

*This conductor is in the inside of the assembly.

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com B

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Wire & Cable Color Coding Charts ICEA Method 1, Table E-2

ICEA Method 3

ICEA Method 4

(Neutral colored compound with tracers)

(Neutral or single color compound with surface printing of numbers and color designations)

(Neutral or single color compound with surface printing of numbers)

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

Background or Base Color Black Red Blue Orange Yellow Brown Red Blue Orange Yellow Brown Black Blue Orange Yellow Brown Black Red Orange Yellow Brown Black Red Blue Yellow Brown Black Red Blue Orange Brown Black Red Blue Orange Yellow

Tracer Color Black Black Black Black Black Red Red Red Red Red Blue Blue Blue Blue Blue Orange Orange Orange Orange Orange Yellow Yellow Yellow Yellow Yellow Brown Brown Brown Brown Brown

Printed Legend 1 – Black 2 – White 3 – Red 4 – Green 5 – Orange 6 – Blue 7 – White–Black 8 – Red–Black 9 – Green–Black 10 – Orange–Black 11 – Blue–Black 12 – Black–White 13 – Red–White 14 – Green–White 15 – Blue–White 16 – Black–Red 17 – White–Red 18 – Orange–Red 19 – Blue–Red 20 – Red–Green 21 – Orange–Green

*This conductor is in the inside of the assembly.

Printed Legend 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

*This conductor is in the inside of the assembly.

*This conductor is in the inside of the assembly.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

B


Return to Table of Contents

Wire & Cable Color Coding Charts ICEA Method 5 (Colored compounds with tracers)

Cond. Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43

Background or Base Color Black White Red Green Orange Blue White Red Green Orange Blue Black Red Green Blue Black White Orange Blue Red Orange Black White Orange Blue Red Orange Black White Red Green Orange Blue Black White Orange White Black White Red Green Orange Blue

First Tracer Color – – – – – – Black Black Black Black Black White White White White Red Red Red Red Green Green White Black Black Black Black Black Red Red Black Black Black White White Red White Red White Black White White Red Red

Second Tracer Color – – – – – – – – – – – – – – – – – – – – Red Red White White White White Green Green Green Orange Green Orange Orange Orange Blue Blue Green Green Green Blue Green Green

Cond. Number 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86

Background or Base Color Black White Red Green Orange Blue Black White Red Green Orange Blue Black White Red Green Orange Blue Black White Red Green Orange Blue Black White Red Green Orange Blue Black Red Green Orange Blue Red Green Blue Orange Green Black White Blue

First Tracer Color White Black White Orange Red Red Orange Black Orange Red Black Black Orange Orange Orange Black Green Green Red Orange Black Orange White White Green Green Green White Red Red Orange Orange Red White White White White Black White Red Green Green Green

Second Tracer Color Blue Blue Blue Red Blue Orange Red Orange Black Blue Blue Orange Green Green Green Blue Blue Orange Blue Blue Blue Blue Red Red Blue Blue Blue Red Black Black Blue Blue Black Green Green Orange Orange Green – – – – –

Cond. Number 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

Background or Base Color Black White Red Green Blue Black White Red Green Orange Yellow Yellow Yellow Yellow Yellow Yellow Yellow Black White Red Green Orange Blue Black White Green Orange Blue Black Red Green Orange Blue Black White Red Orange Blue Black White Red

First Tracer Color Orange Orange Orange Orange Orange Blue Blue Blue Blue Blue – Black White Red Green Orange Blue Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow

Second Tracer Color – – – – – – – – – – – – – – – – – – – – – – – Red Red Red Red Red White White White White White Green Green Green Green Green Blue Blue Blue

*This conductor is in the inside of the assembly.

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com B

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Recommended Reel Handling Practices How to Handle Cable Reels

Recycling/Reel Return Broken Reel Extreme Makeover Program Innovative solution to salvage broken reels with good cable on it. Reels are picked up, examined and reran on new reels, avoiding scrapping expensive wire. Empty Wooden Reels Recycled program AWG continuously picks up empty wooden reels at no cost. This eliminates labor and time to breakdown reels, as well as refuse costs.

Cradle both reel flanges between forks.

Upended heavy reels will often arrive damaged. Refuse or receive subject to inspection for hidden damage.

Reels can be hoisted with a shaft extending through both flanges.

Do not lift by top flange. Cable or reel will be damaged.

Lower reels from truck using hydraulic gate, hoist or fork lift. LOWER CAREFULLY!

Never allow forks to touch cable surface or reel wrap.

Always load with flanges on edge and chock and block securely.

Never drop reels.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

C


Return to Table of Contents

Steel Reel Specifications I-Beam Tire Fluted Steel Reel—Type RMT NOTE — When required, cable test hole in the flange shall not have more than 3 flutes removed to provide this opening. The cable test hole shall be reinforced along the cutout with a metal equal to or greater than that required for use in the drum of the reel. Height of cable test hole to be no greater than onehalf the length.

30° TRAVERSE

Y”

1” RADIUS LAG OPENING

FLANGE DIAMETER

DRUM DIAMETER

THE LAG OPENING SHOULD BE WELL ROUNDED AND GROUND SMOOTH

TIRE

HEAD SHEET

DRUM

INNER RING ARBOR HOLE FLUTES LONG CROSS ARM SHORT CROSS ARM

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

D


Return to Table of Contents

Steel Reel Specifications General Purpose Steel Fluted Returnable Reels for Wire and Cables—Class 1 Type*

–Reel Dimensions– Max. Arbor Max. Fl Trav Drum Overall Hole Number Width Diameter Flutes (in) (in) per Hd

RM 42 RM 48 RM 54 RM 60 RM 66 RM 72 RM 72 RM 78 RMT 84 RMT 84 RMT 84 RMT 90 RMT 90 RMT 90 RMT 96 RMT 98 RMT** 108

24 24 32 32 32 36 36 36 36 45 45 45 45 54 60 60 74

24 24 32 32 36 40 48 48 42 42 56 42 56 56 42 56 56

33 33 41 41 41 45 45 45 45 55 55 55 55 64 71 71 85

3.25 3.25 3.25 3.25 3.25 3.25 3.25 3.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25

24 24 30 30 32 40 40 40 40 40 40 40 40 40 40 40 40

Tire Size (in)

2x5/16 2x5/16 2x5/16 2x5/16 2-1/2x1/2 2-1/2x1/2 2-1/2x1/2 2-1/2x5/8† 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam

–––––Cross Arms––––– U.S.S. Long Short (ga) (in) (in)

8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

5x2 5x2 5x2 5x2 6x2 6x2 6x2 6x2 7-7/8x2 7-7/8x2 7-7/8x2 7-7/8x2 7-7/8x2 7-7/8x2 7-7/8x3 7-7/8x3 7-7/8x3

Drum U.S.S. (ga)

4x2 4x2 4x2 4x2 5x2 5x2 5x2 5x2 6x2 6x2 6x2 6x2 6x2 6x2 6x3 6x3 6x3

12 12 12 12 12 12 12 12 10 10 10 10 10 8 8 8 8

Inner (Flange) Maximum Ring Head –––Capacity––– Dimensions Sheet (lb) (kg) (in) U.S.S. (ga) 3-3/4x3/16 3-3/4x3/16 3-3/4x3/16 3-3/4x3/16 3-3/4x3/16 3-3/4x1/4 3-3/4x1/4 3-3/4x1/4 4x1/4 4x1/4 4x1/4 4-1/4x1/4 4-1/4x1/4 4-1/4x1/4 4-1/2x5/16 4-1/2x5/16 4-1/2x5/16

16 16 16 16 16 16 16 16 16 16 16 16 16 16 14 14 14

1,956 887 3,072 1,393 4,464 2,024 6,360 2,884 7,680 3,482 10,260 4,654 7,872 3,570 10,752 4,876 13,608 6,171 17,004 7,711 11,196 5,050 21,036 9,540 15,216 6,900 18,252 8,277 26,000 11,719 26,000 11,719 30,000 13,605

* RM—Flat bar tire ** Generally used for aluminum wire and cable † Alternate size is 3x1/2 inch RMT—I-Beam Tire NOTE—Tie holes, if necessary, shall be in the flat portion of the head sheet. There will be no holes in the flute itself. NOTE—A range of 3 to 3.25-inch and 5 to 5.25-inch arbor hole diameter shall be permitted for existing reels until the year 2005.

Welding Requirements for Class 1 Reels Head sheet to tire—at all radii of flute-intermittent weld Head sheet to inner ring—at all radii of flute-intermittent weld Drum to inner ring—intermittent weld Cross arm to cross arm—continuous weld Cross arm to inner ring—continuous weld Cross arm to hub—continuous weld Back-up plate to hub and cross arm—continuous weld Port frame—continuous weld All welds shall reflect good welding practice with proper penetration.

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com D

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Metric Size to AWG Size Area (mm2)

Size AWG/MCM

Nominal Overall Diameter (mm)

Nominal Overall Diameter (in)

Number of Wires

Area (mm2)

Size AWG/MCM

Nominal Overall Diameter (mm)

Nominal Overall Diameter (in)

Number of Wires

1010 1000 887 800 760 633 507 500 400 380 304 300 253.4 240 203 185 177 152 150 127 120 107.2 95 85.01 70 67.43 53.49 50

2000

41.45 41.14 38.76 36.81 35.87 32.74 29.26 29.05 25.97 25.35 22.68 22.46 20.65 20.09 18.49 17.64 17.30 16.00 15.85 14.61 14.15 13.41 12.60 11.94 10.86 10.64 9.47 9.15

1.632 1.620 1.526 1.448 1.412 1.289 1.152 1.143 1.023 0.998 0.893 0.884 0.813 0.792 0.728 0.695 0.681 0.630 0.624 0.575 0.558 0.528 0.497 0.470 0.427 0.419 0.373 0.361

127 91 127 61 91 91 61 37 37 61 61 37 37 37 37 37 37 37 19 37 19 19 19 19 19 19 19 19

42.41 35 35 33.62 26.67 25 21.15 16 13.30 10 8.37 6.0 5.26 4.0 3.31 2.5 2.08 1.5 1.31 1.0 0.82 0.75 0.52 0.50 0.33 0.25 0.20

1

8.43 7.65 7.56 7.42 6.61 6.39 5.89 5.13 4.67 4.05 3.71 3.12 2.95 2.55 2.34 2.01 1.85 1.56 1.47 1.29 1.02 0.98 0.81 0.80 0.64 0.56 0.51

0.332 0.302 0.298 0.292 0.260 0.252 0.232 0.202 0.184 0.160 0.146 0.123 0.116 0.101 0.092 0.080 0.073 0.062 0.058 0.051 0.046 0.039 0.032 0.031 0.025 0.022 0.020

19 19 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

1750 1500 1250 1000

750 600 500 400 350 300 250 4/0 3/0 2/0 1/0

2 3 4 6 8 10 12 14 16 18 20 22 24

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

E


Return to Table of Contents

Copper Conductor Stranding Chart Class A thru M Size AWG

36 35 34 33 32 30 30 29 28 27 26 25 24 23 22 21 20 18 16 14 12 10 9 8 6 4 3 2 1 1/0 2/0

Concentric Strand Class A

Concentric Strand Class B

Concentric Strand Class C

Concentric Strand Class D

Rope Lay Concentric Strand Class G

Rope Lay Concentric Strand Class H

Rope Lay Bunch Strand Class I 24AWG (.201")

Rope Lay Bunch Strand Class M 30AWG (.010")

Rope Lay Bunch Strand Class K 34AWG (.0063")

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 7 7 7 7 7 7

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 7 7 7 7 7 7 7 7 7 7 7 7 19 19 19

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 19 19 19 19 19 19 19 19 19 19 19 19 37 37 37

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 37 37 37 37 37 37 37 37 37 61 61 61

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 49 49 49 49 49 49 49 49 49 133 133 133

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 133 133 133 133 133 133 259 259 259

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 26 N/A 41 63 105 N/A 161 210 266 342

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 10 16 26 41 65 104 N/A 168 266 420 532 665 836 1064 1323

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 26 41 65 104 186 259 N/A 420 665 1064 1323 1666 2107 2646 3325

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

G


Return to Table of Contents

Wire & Cable Glossary of Terms AWG Abbreviation for American Wire Gauge. AWM Designation for appliance wiring material. Alternating Current Electric current that continually reverses its direction. Is expressed in cycles per second (hertz or Hz). Ambient Temperature The temperature of the medium (gas, liquid or earth) surrounding an object. American Mustang A premium grade thermoset cord, UL listed as SOOW or SJOOW, CSA SOOW and SJOOW. American Wire Gauge (AWG) A standard system for designating wire diameter. Also referred to as the Brown and Sharpe (B&S) wire gauge. Ampacity See Current Carrying Capacity. Ampere The unit of current. One ampere is the current flowing through one ohm of resistance at one volt potential. Anneal Relief of mechanical stress through application of heat and gradual cooling. Annealing copper renders it soft and less brittle. Audio Frequency The range of frequencies audible to the human ear. Usually 20–20,000 Hz. Braid A fibrous or metallic group of filaments interwoven in cylindrical form to form a covering over one or more wires. Breakdown Voltage The voltage at which the insulation between two conductors breaks down. Bunch Stranding A group of wires of the same diameter twisted together without a predetermined pattern. Cabling The twisting together of two or more insulated conductors to form a cable. Capacitance The ability of a dielectric material between conductors to store electricity when a difference of potential exists between the conductors. The unit of measurement is the farad, which is the capacitance value that will store a charge of one coulomb when a one-volt potential difference exists between the conductors. In AC, one farad is the capacitance value that will permit one ampere of current when the voltage across the capacitor changes at a rate of one volt per second. Circuit (Electric) The complete path of an electrical current. When the continuity is broken, it is called an open circuit; when continuity is maintained, it is called a closed circuit. Cold Flow Permanent deformation of the insulation due to mechanical force or pressure (not due to heat softening).

Color Code A system for circuit identification through use of solid colors and contrasting tracers. Compound An insulating or jacketing material made by mixing two or more ingredients. Concentricity In a wire or cable, the measurement of the location of the center of the conductor with respect to the geometric center of the surrounding insulation. Conductor An uninsulated wire suitable for carrying electrical current. Contacts The parts of the connector that actually carry the electrical current and that touch the equivalent parts in the mating connector. Continuity Check A test to determine whether electrical current flows continuously throughout the length of a single wire or individual wires in a cable. Cord A flexible insulated wire suitable for carrying electric current. Corona Ionization of air surrounding a conductor caused by the influence of high voltage. Causes deterioration of insulation materials. Crazing The minute cracks on the surface of plastic materials. CSA Abbreviation for Canadian Standards Association, a nonprofit, independent organization that operates a listing service for electrical and electronic materials and equipment. The Canadian counterpart of the Underwriters Laboratories Current Carrying Capacity The maximum current an insulated conductor can safely carry without exceeding its insulation and jacket temperature limitations. It is dependent on the installation conditions. Decibel (db) A unit that expresses differences of power or voltage level. It is used to express power loss in passive circuits or cables. Dielectric Strength The voltage that an insulation can withstand before breakdown occurs. Usually expressed as a voltage gradient (such as volts per mil). Direct Capacitance The capacitance measured directly from conductor to conductor through a single insulating layer. Drain Wire In a cable, the uninsulated wire laid over the shield component or components and used as a ground connection. Drawing In wire manufacture, pulling the metal through a die or series of dies to reduce diameter to a specified size.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida

F


Return to Table of Contents

Wire & Cable Glossary of Terms Eccentricity Like concentricity, a measure of the center of a conductor's location with respect to the circular cross section of the insulation. Expressed as a percentage of displacement of one circle within the other. Elongation The fractional increase in length of a material stressed in tension. EMI Abbreviation for electromagnetic interference. Farad A unit of electrical capacitance. Filler 1) A material used in multiconductor cables to occupy large interstices formed by the assembled conductors; 2) An inert substance added to a compound to improve properties or decrease cost. Flame Resistance The ability of a material to resist the propagation of flame once the heat source is removed. Flex Life The measurement of the ability of a conductor or cable to withstand repeated bending. Frequency The number of times an alternating current repeats its cycle in one second. G An industry designation for a 2kV portable power cable consisting of 2 4 insulated conductors with ground wires placed in the valleys for use in mines and similar applications. Gauge A term used to denote the physical size of a wire. G-GC designation An industry for a 2kV portable power cable consisting of 3 insulated conductors with 2 ground wires, and a ground check conductor. For use in mines and similar applications. Ground An electrical term meaning to connect to the earth or other large conducting body to serve as an earth, thus making a complete electrical circuit. Harness An arrangement of wires and cables, usually with many breakouts, which have been tied together or pulled into a rubber or plastic sheath, used to interconnect an electric circuit. Hertz (Hz) A term replacing cycles per second as an indication of frequency. Hi-Pot A test designed to determine the highest voltage that can be applied to a conductor without breaking through the insulation. HPD Heater cord with thermoset insulation and cotton or rayon braid overall. HPN Parallel heater cord.

Hz Abbreviation for hertz. Impedance The total opposition that a circuit offers to the flow of alternating current or any other varying current at a particular frequency. It is a combination of resistance R and reactance X, measured in ohms. Inductance The property of a circuit or circuit element that opposes a change in current flow, thus causing current changes to lag behind voltage changes. It is measured in henrys. Insulation A material having high resistance to the flow of electric current. Often called a dielectric in radio frequency cable. Jacket An outer non-metallic protective covering applied over an insulated wire or cable. Jumper Cable A short flat cable interconnecting two wiring boards or devices. Lay The length measured along the axis of a wire or cable required for a single strand (in stranded wire) or conductor (in cable) to make one complete turn about the axis of the conductor or cable. Longitudinal Shield A tape shield, flat or corrugated, applied longitudinally with the axis of the core being shielded. MTW Thermoplastic insulated machine tool wire. Multiconductor More than one conductor within a single cable complex. Mylar A synthetic compound with high dielectric qualities made by DuPont and used extensively in the wire and cable industry in tape form. NEMA Abbreviation for National Electrical Manufacturers Association. Ohm A unit of electrical resistance. OSHA Abbreviation for Occupational Safety and Health Act, specifically the Williams Steiger Law passed in 1970 covering all factors relating to safety in places of employment. Plasticizer A chemical agent added to plastics to make them softer and more pliable. Potting The sealing of a cable termination or other component with a liquid that cures into an elastomer. Primary Insulation The first layer of nonconductive material applied over a conductor, whose prime function is to act as electrical insulation.

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com F

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright Š 2010, American Wire Group, Inc. Hallandale, Florida


Return to Table of Contents

Wire & Cable Glossary of Terms Put-Up Packaging of finished wire or cable by size and length. PVC Abbreviation for polyvinylchloride. Rated Voltage The maximum voltage at which an electrical component can operate for extended periods without undue degradation or safety hazard. REA Abbreviation for Rural Electrification Administration, which is part of the US Dept. of Agriculture. REA establishes specifications and provides approval for telephone station wire and power cables. Resistance A measure of the difficulty in moving electrical current through a medium when voltage is applied. It is measured in ohms. RFI Abbreviation for radio frequency interference. S Heavy duty, rubber insulated portable cord. Standard copper conductors with separator and individual rubber insulation. Two or more color-coded conductors cabled with filler, wrapped with separator and rubber jacketed overall 600V. SEO Same construction as STO, except insulation and jacket are made of Thermoplastic Elastomer Rubber (TPE) 600V. SEOOW Same construction as SEOW, except with oil resistant insulation. SEOW Same construction as SEO, except suitable for outdoor use. Usually UL listed for continuous submersion in water 600V. Separator Pertaining to wire and cable, a layer of insulating material such as textile paper, Mylar, etc., which is placed between a conductor and its dielectric, between a cable jacket and the components it covers, or between various components of multiple conductor cable. It can be utilized to improve stripping qualities and/or flexibility, or can offer additional mechanical or electrical protection to the components it separates. Shield A tape shield, or braid of metal, usually copper, aluminum or other conducting material, placed around or between electric circuits or cables or their components to contain any unwanted radiation, or to keep out an unwanted interference. SJ Junior hard service rubber insulated pendant or portable cord. Same construction as SJT, except insulation and jacket is thermoset (rubber) 300V. SJE Same construction as SJT, except insulation and jacket made of Thermoplastic Elastomer Rubber (TPE)300V. SJEO Same construction as SJO, except insulation and jacket made of Thermoplastic Elastomer Rubber (TPE).

SJEOW Same construction as SEOW except 300 volt rated. SJO Same as SJ, but oil resistant outer jacket. Can also be made “water resistant.” 300V, 60°C, 75°C, 900°C or 105°C. SJOOW Same as SOOW except 300 volt rated. SJT Junior hard service thermoplastic conductors with overall thermoplastic jacket, 300V, 60°C, 75°C, 900C or 105°C. SJTO Same as SJT, but oil resistant thermoplastic outer jacket. SLC Stage Lighting Cable. A 600-volt single conductor cable for use with indoor and outdoor stages, fairs and carnivals. SO Hard service cord. Same construction as type S, except oil resistant thermoset jacket. 600V, 600°C to 105°C. SOOW Same as SOW except oil resistant insulation. SOW Same as SO except suitable for outdoor use. SP-1 All rubber, parallel jacketed, two conductor light duty cord for pendant or portable use. 300V. SP-2 Same as SP-1, but heavier construction, with or without third conductor for grounding purposes. 300V. SP-3 Same as SP-2, but heavier construction for refrigerators or room air conditioners. 300V. Spacing Distance between the closest edges of two adjacent conductors. Spark Test A test designed to locate pinholes in the insulation of a wire or cable by application of a voltage for a very short period of time while the wire is being drawn through a field of electrodes. SPE Same construction as SP-1, except insulation and jacket made of Thermoplastic Elastomer Rubber (TPE). Spiral Wrap The helical wrap of a tape or other material over a core or component. SPT-1 Same as SP-1, except all thermoplastic, 300V. With or without third conductor for grounding. SPT-2 Same as SP-2, except all thermoplastic. 300V. With or without third conductor for grounding. SPT-3 Same as SP-3, except all thermoplastic. 300V. With or without third conductor for grounding.

AMERICAN WIRE GROUP 1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

TOLL FREE 1-800-342-7215 www.buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida

F


Return to Table of Contents

Wire & Cable Glossary of Terms ST Hard service cord, jacketed. Same as type S, except all plastic construction. 600V, 600°C to 105°C. STO Same as ST, but with oil resistant thermoplastic outer jacket. 600V, 600°C to 105°C. Strand A single uninsulated wire. Stranded Conductor A conductor composed of wires or groups of wires twisted together. Surge A temporary and relatively large increase in the voltage or current in an electric circuit or cable. Also called a transient. SV Vacuum cleaner cord, rubber insulated with rubber jacket, rated at 300V. SVE Same construction as SV, except insulation and jacket made of Thermoplastic Elastomer (TPE). SVT Same as SV, except all plastic construction. With or without third conductor for grounding purposes only. 300V, 600°C to 105°C. TC Tray Cable. Multi-conductor cable specifically approved for use installed in cable trays. Tensile Strength The pull stress required to break a given specimen. Thermoplastic A material that softens and melts when heated and becomes firm on cooling.

Thermoset A material that hardens or sets when heat is applied and that, once set, cannot be resoftened by heating. The application of heat cures or vulcanizes the material. TPE Abbreviation for Thermoplastic Elastomer. UL Abbreviation for Underwriters Laboratories, a nonprofit independent organization that operates a listing service for electrical and electronic materials and equipment. Voltage The term most often used in place of electromotive force, potential, potential difference or voltage drop to designate the electrical pressure that exists between two points and is capable of producing a current when a closed circuit is connected between two points. VW-1 A flammability rating established by Underwriters Laboratories for wires and cables that pass a specific vertical flame test, formerly designated FR-1. W (Type) An industry designation for a 2kV portable power cable consisting of 1–6 insulated conductors. For use in mines and similar severe duty applications. W UL designation for outdoor listed flexible cord that is tested for sunlight and weather requirements (e.g., 5TW). Water Resistant UL designation for cords that have an insulation on the individual conductors that passes UL requirements (e.g., 5T Water Resistant or 5T Dry 105°C, Water Resistant 60°C).

AMERICAN WIRE GROUP

TOLL FREE 1-800-342-7215 www.buyawg.com F

1920 E. Hallandale Beach Blvd. Suite PH8 Hallandale, Florida 33009 Telephone: 1-954-455-3050 Fax: 1-954-455-9886 E-Mail: sales@buyawg.com

Information on this sheet subject to change without notice. Copyright © 2010, American Wire Group, Inc. Hallandale, Florida


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.