Luis Garcia Work Sample

Page 1

Luis D Garcia

Work sample


Entrance view

Court Yard view towards the multipurpose space

Play Yard Nursery School

1. Looping circulation

Location: Culver City, CA Year: Fall 2017 Woodbury University

2. Apply to site

This project is about freedom of movement and fluidity. The project contains a looping circulation that encourages play. The circulation creates courtyards that exposed kids to nature for them to play and learn.

3. Twist

Concept diagram


Planters Services

Storm water harvesting and use on site

Kids closer to nature

Natural lighting & Ventilation

N

Section model

Passive design strategies

<1000 Lux

9

500-1000 Lux 300-500 Lux

1

12

1

11 10

8

6 1 2 3 5

4

1

7 1

1. Learning spaces 2. Multipurpose space 3. Administration 4. Parent room 5. Meeting room 6. Wet area 7. Animal room 8. Back yard 9. Green House 10. Theater 11. Dinning 12. Kitchen

>300 Lux

1st level

2nd level < 1000 Lux 500-1000 Lux 300-500 Lux >300 Lux

Natural lighting analysis

North Elevation

0’

20’

40’


Open Open andand close close

Massing Massing + Formal + Formal concept concept

Typology: Typology: Tower Tower + courtyard + courtyard Location: Location: BoyleBoyle Heights, Heights, Los Angeles Los Angeles

Adjacent Adjacent Site: Site: Park Park

View to the new 6th Street bridge Semipublic Public

1. Courtyard

2. Removed for exposure

1 Courtyard 1 Courtyard

mass mass to allow to allow exposure exposure 2 Removed 2 Removed

3. Open for public 3 Public access 3 Public access

Mission Rd Housing Location: Boyle Heights, Los Angeles CA Year: 2016 Woodbury University The site is by the new 6th Street Bridge and next to a small park. The lack of park and public spaces in Los Angeles and Boyle Heights proposes a design in which the side can become part of the public space. The design tries to connect the park adjacent to the site and the new park proposed under the new 6th Street Bridge.

4. Extrude work spaces 4 Extrude

4 Extrude


Inspired by Le Corbusier’s Unite d’Habitation, the proposed units interlocked. The interlocking design helps the units to have double exposure to lighting, ventilation, and two levels.

Open and close

Cross section

Typology: Location: Site:

Aggregation

Courtyard Boyle Heights, Los Angeles Park Adjacent

Type 2 Type 1 DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

Units 2nd level 1 Part to whole 1-

Underground parking

2-

Retail

3-

Office

4-

Service & support

5-

Residential

2 Units 1-

type 1

2-

type 2

rk Wo

n

che Kit ep

Sle

Units 1st level

Interlocking unit

on

mm

Co


ROBERT

SIDE YARD

PROP.

architecture design, 5749 VENICE BOULEVARD LOS ANGELES, CA 90019 323 746 5020

(E) RETAINING WALL TO

www.rkad.com

PROP.

CONC. SLAB DOORS TO STACK HERE WHEN

STAIR UP TO

100

CONC. STAIR UP 100B

(N) RETAINING

UP 554' - 6"

DOORS TO STACK HERE WHEN

(N) FENCE ALONG 100A

(E) ALLEY

STEEL 100A

25' - 0"

Living space view

Gallery view

SIDE YARD

EDGE OF

(N) RETAINING

15

5' - 4"

RAMP UP TO

1st FLOOR PLAN SCAL 1/4" = 1'-0"

15 A 401

07

13

07

05

A 401

A 402

A 402

A 402

05

15 A 300

01

A 600 206A

EQ

A 600

4954 E MERIDIAN STREET LOS ANGELES, CA 90042

STAIR 01

LIVING ROOM

3' - 0"

MERIDIAN RESIDENCE

UP

1' - 6"

205

1' - 6"

204

13

EQ

09

A 601

202A

202B

A 601

201

ROBERT

architecture design,

202

D

204

05 A 301

25' - 9"

3' - 4" DN

6' - 6"

09 A 602

STAIR 01 15 100F

10' - 8"

2 13 A 600

A 600 602

100A 100B

STAIR 203B

203G

203A

ENCLOSED STAIR

01 A 602

A 300

Written dimensions shall have precedence over scaled dimensions. The Contractor shall verify and be responsible for all dimensions and conditions on hte jobsite and report any discrepancies to the Architect.

200A

200

559' - 0"

13

A 601

The drawings and specifications indicate the general scope of work and required technical

PROP.

performance of 17012 the building systems and do JOB NUMBER:

201C 100G

100F 200B

not necessarily indicate or describe all the work for full performance and NO.required ISSUE DATE compliance of the construction08 contract 01 PLAN CHECK 14

100E

A 601

16 A 800

1st & 2nd FLOOR PLANS

PAGE NUMBER

A 200

2nd FLOOR PLAN SCAL 1/4" = 1'-0"

15

17

PAGE TITLE

EXPOSED POURED IN PLACE CONC. STEM WALL

1st FLOOR 554' - 6"

13

203K

01

UP

4' - 6" A 400

201A

2nd FLOOR 559' - 0"

4' - 6"

1st FLOOR 554' - 6"

13

203J

05

201

203

203F

100E

100A

2' - 11" 203H

2-CAR GARAGE

DEN

05 A 602

13 3

323 746 5020

The drawings and specifications and design represented hereby are and shall remain the property of the Architect, and no part therein shall be used or reproduced for any purpose other than the specified project for which they have been prepared and developed without the written consent of the Architect.

A 301

3rd FLOOR 569' - 8"

A 400

2' - 4 3/4"

MASTER BEDROOM

LINE OF FLOOR PROP.

203E

100B

2nd FLOOR 559' - 0"

6' - 6 3/4"

203A

203E 100G

25' - 9"

03 A 602

3rd FLOOR 569' - 8"

559' - 0"

203K

PROP.

202

ROBERT KERR architecture design, Inc. www.rkad.com © This drawing is copyrighted - 2017

201B

MERIDIAN RESIDENCE

203J

LIVING ROOM

10' - 8"

10' - 7"

01 A 802

203H

PROP.

10' - 7"

CEMENT

5749 VENICE BOULEVARD LOS ANGELES, CA 90019

(N) CONC. SUN SHADE

REAR YARD SECTION

07

SCAL 1/4" = 1'-0"

Floor Plan

LIVING ROOM SECTION SCAL 1/4" = 1'-0"

3/15/2018 7:47:51 PM

W

205

13

13

204 TOP OF ROOF 580' - 3"

205

DN

A 401

TOP OF ROOF 580' - 3"

ROBERT KERR architecture design, Inc. © This drawing is copyrighted - 2017 The drawings and specifications and design represented hereby are and shall remain the property of the Architect, and no part therein shall be used or reproduced for any purpose other than the specified project for which they have been prepared and developed without the written consent of the Architect.

10' - 7"

301 300B

Written dimensions shall have precedence over scaled dimensions. The Contractor shall verify and be responsible for all dimensions and conditions on hte jobsite and report any discrepancies to the Architect.

204 206A

PTD. DRYWALL

The drawings and specifications indicate the general scope of work and required technical

performance of 17012 the building systems and do JOB NUMBER: not necessarily indicate or describe all the work for full performance and NO.required ISSUE DATE compliance of the construction08 contract 01 PLAN CHECK 14

17

10' - 8"

25' - 9"

3rd FLOOR 569' - 8"

201

205

2nd FLOOR 559' - 0" EXPOSED POURED IN PLACE CONC. STEM WALL

4' - 6"

1st FLOOR 554' - 6"

13

BUILDING SECTION SCAL 1/4" = 1'-0"

Building Section

PAGE TITLE

BUILDING SECTIONS

PAGE NUMBER

A 401

3/15/2018 7:48:20 PM

Summer Internship Robert Kerr Architecture and Design Location: Los Angeles Year: 2017 Role: 3d model in Rhino, model making, renderings, and construction documents in Revit.

LAUNDRY

TOILET

7' - 11"

13 A 802

TOP OF ROOF 580' - 3"

Meridian House

SUN SHADE

1' - 6" 1' - 6"

09 A 600

MASTER BATH

4954 E MERIDIAN STREET LOS ANGELES, CA 90042

D


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.