Ethylene Unit Cracked Gas Compressor Case Studies on Fouling Visagaran Visvalingam - Presenter Cyron Anthony Soyza Sew Nyit Tong Karl Kolmetz
Outlines ? ? ? ? ? ? ? ?
Overview of Equipment and Setup CGC Fouling Experiences Identification of Turbine Fouling Impacts of Compressor-Turbine fouling Turnaround Inspections Countermeasures for Fouling Control Future Improvements Conclusions
Overview of Equipment & Setup • CGC is a five stages centrifugal compressor • Caustic wash and drying are facilitated between 4th and 5th stage • 5th stage is a heat pump for DeC3 system where C4 and heavier are removed • CGC is driven by a SHP steam turbine • Turbine extracts HP steam while condensing is controlled by CGC power demand
Compressor System Flow Diagram Wash Oils
Stage 1
Stage 2
Stage 3
Stage 4
Cracked Gas
Acetylene Converters Caustic & Dryers
Stage 5
HP DeC3
To Recovery Section
Compressor Overview Diffusers Inlet Vanes
Wheels
Balance Line
Fouling Phenomenon - What,Why and How •
• •
Organic : Free radical mechanism catalyzed by peroxides, transition metals and heat Inorganic : Quench water carryover Organic or inorganic deposits dehydrogenate over time leaving behind
R-H
Initiate
heat
•R
•H O2
Propagate
• ROO R-H
ROOH + •R
Terminate •R + •R
CGC Fouling Experiences £ Polytropic efficiencies dropped £ Discharge temperatures increased £ Inter-cooler pressure drops increased £ Governor valve opening maximum £ Turbine steam rate increased £ Max continuos speed not sustainable
CGC Polytropic Efficiency 90
85
AFTER TURNAROUND 96
AFTER TURNAROUND 99
TURNAROUND 2001
Efficiency (%)
80
75
70
65
60
55
50
01 1/ /0 05 00 2/ /1 12 00 1/ /1 04 00 9/ /0 07 00 7/ /0 10 00 5/ /0 03 00 3/ /0 06 00 1/ /0 02 99 2/ /1 25 99 0/ /1 07 99 7/ /0 16
9 /9 /3 23 98 2/ /1 05 8 /9 /9 16
8 /9 /5 21 97 2/ /1 23 7 /9 /9 29
7 /9 /4 30 96 1/ /1 25 6 /9 /6 28 6 /9 /4 23
2nd stg Polly. Eff
3rd stg Polly. Eff
4th stg Polly. Eff
5th stg Polly. Eff
Stage 1 delta T Stage 2 delta T Stage 3 delta T Stage 4 delta T
04
07
/1
/0
/0
/0
/0
/0
/1
/1
/0
1/
9/
7/
5/
3/
1/
2/
0/
8
00
00
00
00
00
00
99
99
99
9
98
/9
7/
/3
2/
/9
8
AFTER TURNAROUND 99
10
03
06
02
25
07
16
23
/1
/9
/9
AFTER TURNAROUND 96
05
16
/5
7
7
97
/9
/9
2/
/9
/1
21
23
29
6
6
96
/9
/9
1/
/4
/1
30
25
/6
/4
65
28
23
Compressor Delta T
70
TURNAROUND 2001
60
55
50
45
40
35
30
Identification of Turbine Fouling ?
Unable to maintain speed at max steam flow HP and LP valve fully open Backpressure from LP turbine
? ? SHP
P1
P2 LP Valve
HP Valve
HP Casing
LP Casing HP Steam Extraction
Exhaust Steam
Causes of Turbine Fouling • BFW quality upset – High Sodium / Silica due to capacity overrun or improper regeneration of demin train
• Water Carry-over – Steam drum level control high
• Steam contamination – Attemporating water high in sodium or silica
Water level
Impacts of Compressor-Turbine Fouling £ Throughput limited due to maximum driver governor valve opening £ Increased suction pressure £ Energy inefficient due to higher steam rate £ Short run length, 3 years down for cleaning
Turnaround Inspections • Inspection done during TA99 and TA 2001 • 1st and 5th stage - relatively clean • 2nd, 3rd & 4th stage - heavily fouled • Polymer deposits and most samples were organic component • Inter-coolers fouled with polymers and tars • Discharge piping layered with polymer
CGC Inspection- TA99 & TA2001 Summary of the Inspection Findings Suct/Disch piping 1st stage 2nd stage 3rd stage 4th stage 5th stage Turbine
Impeller/ Diffuser
Volute
1st to 4th Stage Discharge Condition during Turnaround 2000/01
1st Discharge
2nd Discharge
3rd Discharge
4th Discharge
Rotor
Casing
2nd stage intercooler bundle
Polymer laced inlet pipeline
Bundle entrance
Inlet to intercooler
Turnaround inspections - CGC Turbine
Countermeasures for Fouling Control • Compressor wash oil review ¤ ¤ ¤ ¤ ¤
Feed points available at the suction piping Injection spray atomizers enhance distribution Increased wash oil injection rate to 3-4% vol. Quality monitoring - existent gums Quantity monitoring - dP
• Antifoulant Injection ¤ Trial run at the 4th stage - worst case
• Improved BFW quality ¤ Proper Demin regeneration and lower steam drum level
Compressor Wash Oil Review ? 1st to 3rd stage
- HPG + C5
? 4th stage
- HPG
? Specific gravity
- 0.77-0.80
? Aromatic content
- 65 %
? Existent gums
- < 5mg/100ml
? Distillation D-86 â&#x20AC;&#x201C; IBP â&#x20AC;&#x201C; End point
- 70 oC - 185 oC
Anti-foulant Injection • • • • •
Trail run at 4th stage Start of run - 9 May 02 Co-injection with the existing wash oil Injection rate at 2-5 ppm by weight Monitoring parameters : − Polytropic Efficiency − Suction / Discharge Temperatures − Pressure Drop Across Inter-cooler − Steam Consumption − Vibrations
Antifoulant Trial Run
Antifoulant : 2-5 ppm wt based on the 4th stage charge rate
Wash Oils
Stage 1
Stage 2
Stage 3
Stage 4
Cracked Gas
Acetylene Converters Caustic & Dryers
Stage 5 HP DeC3
To Recovery Section
Antifoulant Trial Run Findings • Polytropic efficiency improved - 4-5% • Comp discharge temperature reduced - 3-4oC • Delta T reduced • Pressure drop across inter-cooler maintained • Vibration normal
Efficiency (%) DT
14-06-02
58
57
56
55
54
53
52
51
Compressor Delta T, degC
Dosage 2ppm
04-06-02
25-05-02
15-05-02
05-05-02
25-04-02
76 75 74 73 72 71 70 69 68 67 66 65 15-04-02
05-04-02
26-03-02
16-03-02
06-03-02
24-02-02
14-02-02
04-02-02
25-01-02
15-01-02
05-01-02
4th Stage Polytropic Efficiency, %
4th Stage Polytropic Efficiency and Delta T Dosage 3-4 ppm 61 60
59
70
Eff, %
4th Stage Polytropic Efficiency and Delta T Ave eff = 1st to 3rd stage
80
24-Jun-02 19-Jun-02 14-Jun-02 09-Jun-02 04-Jun-02 30-May-02 25-May-02 20-May-02 15-May-02 10-May-02 05-May-02 30-Apr-02 25-Apr-02 20-Apr-02 15-Apr-02 10-Apr-02 05-Apr-02 31-Mar-02
60
2nd stage 4th stage
C-300 Efficiency
78
76
74
72
68
66
64
62
Future Improvements Wash oil quality – C8+ High aromatics, low gums & higher FBP – Intermittent or Continuos - 0.5% wg – High volume flush - 2% wg
Wash oil and Antifoulant injection to casing – Revamp or TA modification
Wash water injection – max 1% throughput to minimize rotor erosion
Inter-coolers – Antifoulant injection facilities for online cleaning
High efficiency 3D impeller blades (new service) – More efficient and larger gas passage
Conclusions ? A review of equipment and maintenance records are essential to each producer ? Part of this review should include turbine and compressor fouling ? Adequate wash oil selection and antifoulant injection enables cracker extension of cracked gas compressor run lengths by reducing the amount of polymer fouling. ? Any review should also include future optimizations
Thank You
Q&A