REVIT DRAWINGS
Architectural Graduate Thanh Mai Nguyen
CONTENT PREFACE KENNEDY RESIDENCE Address: 1166 Waterworks Road, The Gap, Queensland My role: Architectural Graduate My work: Design Application Skills utilised: Revit, Photoshop
04
CALLUM FARM HOUSE Address: Milbong, Queensland My role: Architectural Graduate My work: Schematic Design Skills utilised: Revit, AutoCAD
26
WESTPOINT SERVICE WORKSHOPS Address: 14 Counihan Road, Seventeen Mile Rocks, Queensland My role: Architectural Graduate My work: Construction Drawings Skills utilised: Revit
37
KIA - JEEP - SUBARU SHOWROOM Address: 4 Lionel Donovan Drive, Noosa, Queensland My role: Architectural Graduate My work: Schematic Design Skills utilised: Revit, Photoshop
60
PHUONG HOUSE Address: 145, 466 Ly Thai To, Nhon Trach District, Dong Nai province My role: Architectural Graduate My work: Schematic Design, Construction Drawings, Client Consultancy Skills utilised: Revit, Photoshop, Indesign
74
PREFACE In August 2020, W.I.M Architects has offered me a valuable opportunity to join their team. Most of the projects at W.I.M Architects gave me a great experience in using Revit for both renovation and new construction. After finishing my work experience at the company, Wim, the company director, has allowed me to print out all of my drawings and add these drawings into my resume. My first project at the company is the Westpoint Service Workshops which allowed me to work on Construction Drawings, learning more about how to integrate timber structure into an existing steel structure. My second project at the company is the Kennedy Residence in which I worked to deliver the Design Application document based on the existing Schematic Design. Another residential project that I worked on is the Callum Farm House which allowed me to work with Wim on the Schematic Design, using Revit to model the new building and completing the whole set of schematic drawings for the client meeting. The last project that I worked on is the Kia-Jeep-Subaru Showroom in which I drew the facade and interior of the building based on different manual standards delivered by Kia, Jeep, and Subaru to complete the Schematic Design. In October, after working at W.I.M Architects, I utilised all skills and knowledge that I have learned to work on Phuong House - a project in Vietnam - in which I worked online with the client and engineers from Vietnam.
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
CALLUM - FARM HOUSE MILBONG Callum Milbong, Queensland, Australia
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
PHUONG HOUSE
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
Description
Date
Phuong House 466 Ly Thai To St Nhon Trach, Dong Nai 830000
Cover Sheet
2020.01
Project number
01/10/2020
Drawn by
Checked by
CD-000
74
Scale
NTM Checker 11/21/2020 2:22:36 PM
Date
Project Name:
Phuong House
Project Client:
Minh Phuong
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
Project Address: 145, 466 Ly Thai To, Nhon Trach District, Dong Nai province SITE AREA Number
Name
1 Site Coverage 2 Site Permeability 3 Site Impermeability 4 Rentable Area Grand total: 4
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
ROOM SCHEDULE Area
175 m² 96 m² 21 m² 125 m² 417 m²
Percentage
Number
42% 23% 5% 30%
1 LIVING ROOM 2 DINING ROOM 3 KITCHEN 4 ATRIUM 5 BEDROOM 1 6 LAUNDRY 7 BATHROOM 1 8 TERRACE 9 ENTRANCE 10 BACKYARD 11 WARDROBE 1 12 MASTER BEDROOM 13 BEDROOM 2 14 BEDROOM 3 15 BATHROOM 2 16 BATHROOM 3 17 WARDROBE 3 18 WARDROBE 2 19 BALCONY 20 STAIR 21 LOFT 22 CIRCULATION 23 CIRCULATION 24 CIRCULATION 25 CONCRETE ROOF Grand total: 25
Name
Area 28 m² 25 m² 14 m² 12 m² 10 m² 5 m² 3 m² 25 m² 13 m² 9 m² 1 m² 23 m² 14 m² 14 m² 8 m² 8 m² 1 m² 1 m² 6 m² 10 m² 50 m² 4 m² 12 m² 9 m² 66 m² 370 m²
Floor Finish FN6026 SEAL FN6026 SEAL FN6026 SEAL EGGER - EPL067 FN6026 SEAL FN6026 SEAL Terrazzo D6713 Skywood - DK14025R FN6026 SEAL
FN6026 SEAL FN6026 SEAL FN6026 SEAL Terrazzo D6713 Terrazzo D6713
FN6026 SEAL EGGER - EPL067 FN6026 SEAL EGGER - EPL067 FN6026 SEAL FN6026 SEAL
Percentage 7.69% 6.82% 3.88% 3.28% 2.77% 1.32% 0.71% 6.83% 3.51% 2.49% 0.26% 6.18% 3.76% 3.77% 2.04% 2.06% 0.31% 0.31% 1.50% 2.59% 13.49% 1.04% 3.14% 2.45% 17.78% 100.00%
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
Description
Date
DRAWING LIST Sheet Name
SD-800 SD-801 SD-802 SD-810 SD-811 SD-812 SD-813
PERSPECTIVES PERSPECTIVES PERSPECTIVES INTERIOR PERSPECTIVES INTERIOR PERSPECTIVES INTERIOR PERSPECTIVES INTERIOR PERSPECTIVES
CD-000 CD-001 CD-100 CD-101 CD-102 CD-110 CD-111 CD-112 CD-113 CD-120 CD-121 CD-122 CD-123 CD-130 CD-131 CD-132 CD-140 CD-200 CD-201 CD-300 CD-301 CD-400 CD-401 CD-402 CD-410 CD-411 CD-420 CD-430 CD-431 CD-432 CD-433 CD-434 CD-500 CD-501 CD-600 CD-610 CD-700 CD-800
Cover Sheet Title Sheet SITE PLAN SITE TRUE NORTH SITE SET-OUT GROUND FLOOR GROUND FLOOR GROUND FLOOR GROUND FLOOR FIRST FLOOR FIRST FLOOR FIRST FLOOR FIRST FLOOR LOFT FLOOR LOFT FLOOR LOFT FLOOR ROOF PLAN ELEVATIONS ELEVATIONS SECTIONS SECTIONS WET AREAS WET AREAS WET AREAS STAIRS STAIRS KITCHEN BEDROOMS BEDROOMS BEDROOMS BEDROOMS BEDROOMS DETAILS DETAILS DOORS WINDOWS MATERIAL DATA PERSPECTIVES
Current Revision Date
10/18/20 10/18/20 10/18/20 10/18/20 10/18/20 10/18/20
10/18/20 10/18/20
10/30/20
Current Revision
Current Revision Description
Updated Dimensions and Structural Solutions Updated Dimensions and Structural Solutions Updated Dimensions and Structural Solutions Updated Dimensions and Structural Solutions Updated Dimensions and Structural Solutions Updated Dimensions and Structural Solutions
Updated Dimensions and Structural Solutions Updated Dimensions and Structural Solutions
Updated Wall Types
1 1 1 1 1 1
1 1
2
Drawing Stage Sketch Design Sketch Design Sketch Design Sketch Design Sketch Design Sketch Design Sketch Design Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings Construction Drawings
Phuong House 466 Ly Thai To St Nhon Trach, Dong Nai 830000
Title Sheet
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
CD-001
75
Scale
NTM Checker 11/21/2020 2:22:37 PM
Sheet Number
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
1
2 2'
3
4
5
6
Description
Date
7
1 CD-301
1
15
15
B
15
CD-300
METAL ROOF
CONCRETE ROOF
466 LY THAI TO STREET
15
C
METAL ROOF
A
Phuong House Site
466 Ly Thai To St Nhon Trach, Dong Nai 830000
1 : 100
SITE PLAN
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
NTM Checker
CD-100
76
Scale
1 : 100
11/21/2020 2:22:40 PM
1
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
1
2 2'
503
4 6960
5
6 10001
7 4780
12983
C
3492
3005
3
4102
Date
2008
1692 88
Description
6410
9019
B
A 5200
13140
Phuong House
Site Set Out
466 Ly Thai To St Nhon Trach, Dong Nai 830000
1 : 100
SITE SET-OUT
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
NTM Checker
CD-102
77
Scale
1 : 100
11/21/2020 2:22:43 PM
1
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
1
2
2'
3
4
5
6
Description
Date
7
21150 700
3600
2300
4450
3300
4900
1200
700
CD-201 1
C
Phuong
2400
8 TERRACE 25.27 m² Skywood - DK14025R
House
FISH POND
B
DN DN
466 Ly Thai To St Nhon Trach, Dong Nai 830000
2 DINING ROOM 25.23 m² FN6026 SEAL
5 BEDROOM 1 10.26 m² 4 FN6026 SEAL
1
3
8600
CD-430 2 CD-200
GROUND FLOOR
5 10 BACKYARD 9.21 m²
4
11 WARDROBE 1 0.97 m²
3 KITCHEN 14.36 m² FN6026 SEAL
4 ATRIUM 12.13 m² EGGER - EPL067
1 LIVING ROOM 28.45 m² FN6026 SEAL
9 ENTRANCE 12.98 m² FN6026 SEAL
6200
CD-200 2
Date
7 BATHROOM 1 3 2.64 m² Terrazzo D6713
2020.01
Project number
CD-400 2
01/10/2020
UP
Drawn by 6 LAUNDRY 4.90 m² FN6026 SEAL
Checked by
NTM Checker
1
CD-110
RL.0.600 Ground Floor 1 : 50
78
Scale
1 : 50
11/21/2020 2:22:50 PM
A
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
1
2
2'
3
4
5
6
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
7
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
20450 3600 900
600
3200
1700
4450
2750
3300
3600
4900
1350
WT 8.0
3095
1200
3710
700
No.
750
Description
Date
CD-201 1
WT 8.0
WT 9.0
WT 7.0
-130 mm
WT 8.0
WT 8.0
CD-430 W G02
W G01
585 110
D G08
WT 5.0
710
6 LAUNDRY 4.90 m² FN6026 SEAL
3300
110
D G06
WT 1.0
9
8
7
6
5
4
3
2
1
UP
WT 1.0
310
815
830
1645
320
8600 WT 8.0
CD-200
Phuong House
WT 2.0
D G04
WT 2.0
WT 8.0
9 ENTRANCE 12.98 m² FN6026 SEAL
1 LIVING ROOM 28.45 m² FN6026 SEAL
WT 8.0
1
3600
D G01
WT 2.0
WT 1.0
WT 8.0
6200
2 DINING ROOM 25.23 m² FN6026 SEAL
2320
D G07
900
WT 5.0
3
25 960
855
-50 mm
100
260
3015
WT 11.0
-150 mm
1250
4 ATRIUM 12.13 m² EGGER - EPL067
10
1 CD-400
B
WT 8.0
466 Ly Thai To St Nhon Trach, Dong Nai 830000
A
GROUND FLOOR
2 CD-411
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
1
RL.0.600 Ground Floor_Dimensions
NTM Checker
1 : 50
CD-111
79
Scale
1 : 50
11/21/2020 2:22:54 PM
4
700
2005
3585
W G03
3 KITCHEN 14.36 m² FN6026 SEAL
11 WARDROBE 1 0.97 m²
5
7 BATHROOM 1 2.64 m² 2 CD-400 Terrazzo D6713
150 1000
WT 2.0
1155
4060
WT 5.0
10 BACKYARD 9.21 m²
800 +0 mm
3
1625
CD-200 2
600
CD-430 2
55 900 50
5 BEDROOM 1 10.26 m² FN6026 SEAL
WT -150 mm 2.0
1200
WT 2.0 DN
D G05
4
WT 8.0
D G02
WT 3.0
800
900 50
210
DN
3190
D G03
WT 2.0
C
600 500
810
1
WT 8.0 WT 8.0
2400
WT 8.0
280
2180
280
8 TERRACE 25.27 m² Skywood - DK14025R
2135
625
WT 8.0 WT 8.0
ARCHITECTURAL GRADUATE NGUYáť„N THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
1
2
2'
3
4
5
6
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
7
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
19750 3600
600
1700
4450
3300
4900
Description
Date
1200
200 x 500mm
2400
C
-200 mm
200 x 500mm
3140
B
-50 mm
-50 mm
8600
-200 mm
-100 mm
-200 mm
6200
-50 mm
200 x 500mm
-50 mm
200 x 500mm
-50 mm
200 x 500mm
200 x 500mm
200 x 500mm
200 x 500mm
200 x 500mm
1850
200 x 500mm
1900
Phuong
-50 mm
House
-50 mm
466 Ly Thai To St Nhon Trach, Dong Nai 830000
1210
200 x 500mm
-50 mm 200 x 500mm
A
GROUND FLOOR
2020.01
Project number
01/10/2020
Drawn by
Checked by
1
RL.0.600 Ground Floor_Structural Plan
NTM Checker
1 : 50
CD-112
80
Scale
1 : 50
11/21/2020 2:22:56 PM
Date
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
1
2
2'
3
4
5
6
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
7
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
800
2400
1250
1200
2400
Description
Date
1300
1200
1200
C TERRACE TIMBER BATTEN
1200
960
B 600
1000
900
958
958
600
BEDROOM 1 PB
600
600 285
1685
1200
FCL 3000
955
958
1200
RAKED CEILING
1500
950
900
Phuong
1500
House 2500
LAUNDRY PB
FCL 3150
2400
958
958 958
1200
ENTRANCE TIMBER BATTEN
LIVING ROOM PB FCL 3000
958
RAKED CEILING
FCL 3200
958
1300
ATRIUM PB
605
1300
FCL 2700
958
780 BATHROOM 1 PB
DINING ROOM PB
958
FCL 3000
605
KITCHEN PB
479 479 479 479 479 479
845
560 545 280 600
600 145
335 600
600
RAKED CEILING
466 Ly Thai To St Nhon Trach, Dong Nai 830000
A 955
1685
960
1300
2100
1200
1200
1500
1500
1000
GROUND FLOOR
2020.01
Project number
01/10/2020
Drawn by
Checked by
1
RL.0.600 Ground Floor_Ceiling Plan
NTM Checker
1 : 50
CD-113
81
Scale
1 : 50
11/21/2020 2:22:57 PM
Date
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
1
2
700
3600
2'
3
4
2300
5
4450
6
3300
4900
Description
Date
7
1200
CD-201 1
C
5 13
13.89 m² FN6026 SEAL
3
4
House
CD-431 2 BEDROOM 2
B
17 WARDROBE 3 1.13 m²
4
CD-430 2
METAL ROOF 15
CD-433 2 3
14 BEDROOM 3 13.96 m² FN6026 SEAL
1
5 4
CD-432 2
STAIR TO LOFT
3
CD-200
FIRST FLOOR
6200
3 CD-200 2
466 Ly Thai To St Nhon Trach, Dong Nai 830000
5
12 MASTER BEDROOM 22.85 m² FN6026 SEAL
18 WARDROBE 2 1.13 m²
8600
4
Phuong
2400
19 BALCONY 5.56 m² FN6026 SEAL
4
2020.01
Project number
5 CD-400 2
Date 5
3 5 15
4
BATHROOM 2 2 CD-401
7.54 m² Terrazzo D6713
20 STAIR 9.57 m² EGGER - EPL067
4
Drawn by
CD-402 2 16 BATHROOM 3 3 7.60 m² Terrazzo D6713
DN
01/10/2020
Checked by
3
NTM Checker
1
CD-120
RL.3.600 First Floor 1 : 50
82
Scale
1 : 50
11/21/2020 2:23:03 PM
A
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
1
2
2'
3
4
5
6
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
7
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
21150 3250 370
CD-201
2925
3100
1200
1500
3300
2
1155
8
7
6
5
4
14
3
2
15
16
3319
935 805
1200 8600
455
3600
CD-200
17
18
19
Phuong House
5 4
+3,550 mm
CD-402 2
1076
16 BATHROOM 3 3 7.60 m² Terrazzo D6713
WT 5.0 20
WT 6.0
1200
1
2300
1
WT 2.0
1631
305
WT 11.0
DN 13
1 CD-434
3
160 900 50 WT 1.0
12
W F10
STAIR TO LOFT
20 STAIR 9.57 m² EGGER - EPL067 11
CD-433 2
+3,600 mm
WT 2.0 9
4
+3,600 mm
260 600 250
22 CIRCULATION 3.85 m² EGGER - EPL067
10
955
4400
210
5
300
1155
3439
1
1
CD-401
CD-402
466 Ly Thai To St Nhon Trach, Dong Nai 830000
A
1506
FIRST FLOOR
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
1
RL.3.600 First Floor_Dimensions
NTM Checker
1 : 50
CD-121
83
Scale
1 : 50
11/21/2020 2:23:07 PM
15 4 CD-401 BATHROOM 2 7.54 m² Terrazzo D6713 3
1095 23 CIRCULATION 11.62 m² FN6026 SEAL
1200
445 D F02
2400
W F03
525
C
B 12 MASTER BEDROOM 22.85 m² FN6026 SEAL
335
D F08
5
D F07
+3,550 mm
W F09
1226
330
1350
300
1250
480
3
WT 6.0
900
CD-400 2
WT 4.0
D F01
D F05
1 CD-432
4
100
D F09
15
525
795
+3,600 3 mm
5
WT 2.0
100 775 100 775 100
1200
CD-432 2
D F06
2400
W F08
4
595
WT 2.0
310
24 CIRCULATION 9.07 m² FN6026 SEAL
2475
5
WT 2.0
1165
2475 14 BEDROOM 3 13.96 m² FN6026 SEAL
5.56 m² FN6026 SEAL
690 600
100
WT 1.0
CD-200 2
2700
18 WARDROBE 2 1.13 m²
1010
W F07
1350 1680
17 WARDROBE 3 1.13 m²
CD-430 2 WT 4.0 3 METAL ROOF
2400
13.89 m² FN6026 SEAL
3
4
W F05
W F04
13
CD-431 2 BEDROOM 2
800
19
+3,550 mm BALCONY
D F03
920
3600
320
WT 9.0
710
5
WT 1.0
2100
WT 9.0
380
W F06
WT 10.0
+3,600 mm
WT 2.0
Date
CD-431
WT 4.0
4
Description
700
1
1
605
4900
1525
2700
3300
1800
605 360
No.
1200
1350
4190
1700
W F02
600
W F01
3600
D F10
700
ARCHITECTURAL GRADUATE NGUYáť„N THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
1
2
2'
3
4
5
6
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
7
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
19750 4450
No. 3300
4900
+3,200 mm
+3,550 mm
+3,550 mm
+3,550 mm 200 x 500mm
200 x 500mm
C
+3,550 mm
1100 2400
+3,200 mm
200 x 400mm
200 x 400mm
+3,500 mm
135
Date
200 x 400mm
200 x 500mm
+3,550 mm
Description
1200
+3,300 mm
1300
1700
200 x 350mm
600
200 x 350mm
3600
+3,550 mm
4400
8600
Phuong House
200 x 300mm
300 x 450mm
+3,500 mm
+3,500 mm
+3,550 mm
+3,500 mm
+3,500 mm
+3,500 mm +3,300 mm
1800
UP
600 600 575 125
6200
+3,550 mm
200 x 400mm
+3,550 mm 200 x 300mm
+3,550 mm
300 x 500mm
+3,550 mm
200 x 300mm
+3,300 mm 200 x 300mm
300 x 500mm
15
200 x 400mm
METAL ROOF
600
600
600
600
+3,550 mm
300 x 500mm
+3,550 mm 200 x 500mm
600 600
300 x 500mm
565
B +3,200 mm
466 Ly Thai To St Nhon Trach, Dong Nai 830000
A 200 x 500mm
FIRST FLOOR
2020.01
Project number
01/10/2020
Drawn by
Checked by
1
RL.3.600 First Floor_Structural Plan
NTM Checker
1 : 50
CD-122
84
Scale
1 : 50
11/21/2020 2:23:08 PM
Date
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
1
2
2'
3
4
5
6
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
7
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
1055
C 493 443
BALCONY TIMBER BATTEN
585
730
2100
BEDROOM 2 PB FCL 2700
790
1580
Date
1055
FCL 2700
1470 730
1600
Description
1580
B
MASTER BEDROOM PB
790
780
FCL 2700
FCL 2700
2950
CIRCULATION PB
795
2300
BATHROOM 2 PB
795
CIRCULATION PB
FCL 2650
STAIR PB
RECESSED CEILING LIGHT
685
1000
1000
780
995
Phuong 2290
1395
House
BATHROOM 3 PB
FCL 2700
FCL 2650
660
735
FCL 2700
1565
795
BEDROOM 3 PB
845
1565
466 Ly Thai To St Nhon Trach, Dong Nai 830000
795
790
910
1580
600 450 450
1580
2100
790
1470
740
FCL 2700
A 850 RECESSED CEILING LIGHT
FIRST FLOOR
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
1
RL.3.600 First Floor_Ceiling Plan
NTM Checker
1 : 50
CD-123
85
Scale
1 : 50
11/21/2020 2:23:10 PM
890
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
1
2
2'
3
4
5
6
Description
Date
7
20450 3600
2300
4450
3300
4900
1200
700
CD-201 1
C 2400
Phuong House B
21 LOFT 49.88 m² FN6026 SEAL
25 CONCRETE ROOF 65.76 m²
1
CD-200
LOFT FLOOR
6200
CD-200 2
8600
466 Ly Thai To St Nhon Trach, Dong Nai 830000
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
NTM Checker
1
CD-130
RL.6.900 Loft Floor 1 : 50
86
Scale
1 : 50
11/21/2020 2:23:16 PM
A
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
1
2
2'
3
4
5
6
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
7
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
20450 3600
2300
4450 3955
3300 2899
4900
3151
1385
1200 3400
700
No.
2115
Description
Date
CD-201 1
W L01
WT 9.0
WT 9.0
320
515
WT 1.0
2400
WT 1.0
C
701 WT 2.0
21 LOFT 49.88 m² FN6026 SEAL
2320
+6,850 mm
WT 2.0
CD-200
+6,900 mm
Phuong
TRAP DOOR TO BE ASSEMBLED ON THE FLOOR OPENING
WT 2.0
House W L02
600
D L01
1
900
305
1210
1290
8600
7130 25 CONCRETE ROOF 65.76 m²
1805
CD-200 2
4395
WT 1.0
210 610
9415
B
466 Ly Thai To St Nhon Trach, Dong Nai 830000
A
LOFT FLOOR
2020.01
Project number
01/10/2020
Drawn by
Checked by
1
RL.6.900 Loft Floor_Dimensions
NTM Checker
1 : 50
CD-131
87
Scale
1 : 50
11/21/2020 2:23:17 PM
Date
ARCHITECTURAL GRADUATE NGUYáť„N THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
1
2
2'
3
4
5
6
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
7
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
Description
Date
19750 3600
600
1700
4450
3300
4900
1200
+6,800 mm 200 x 500mm
200 x 500mm
2400
+6,850 mm
+6,850 mm +6,800 mm
2400
2400
C
+6,800 mm 200 x 500mm
800
B 200 x 500mm
8600
4395 6200
+6,850 mm
300 x 500mm
200 x 300mm
300 x 500mm
+6,800 mm
300 x 500mm
+6,800 mm
200 x 500mm
300 x 500mm
3100
+6,850 mm
+6,850 mm
Phuong
200 x 300mm
House
+6,800 mm
+6,800 mm
+6,800 mm +6,850 mm
+6,850 mm
1805
2300
200 x 500mm
466 Ly Thai To St Nhon Trach, Dong Nai 830000
200 x 500mm
A
LOFT FLOOR
2020.01
Project number
01/10/2020
Drawn by
Checked by
1
RL.6.900 Loft Floor_Structural Plan
NTM Checker
1 : 50
CD-132
88
Scale
1 : 50
11/21/2020 2:23:18 PM
Date
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
1
2
2'
3
4
5
6
Description
Date
7
21151 700
3600
2300
4450
3300
4900
1200
700
Phuong
2400
15
C
House B
8600
15
466 Ly Thai To St Nhon Trach, Dong Nai 830000
6200
ROOF PLAN
15
METAL ROOF
2020.01
Project number
METAL ROOF
Date
01/10/2020
Drawn by
Checked by
NTM Checker
1
CD-140
Roof Plan 1 : 50
89
Scale
1 : 50
11/21/2020 2:23:20 PM
A
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
A
B
C
C
B
A
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
8600
8600 6200
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
2400
2400
6200
+10,816 mm
+10,816 mm
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
15 15
METAL ? ROOF
No. +8,298 mm
Description
Date
+8,298 mm
GALVANISED ? STEEL CABLE
RL.6.900 Loft Floor
RL.6.900 Loft Floor
6900
6900
3300
3300
TIMBER BATTEN 50X100mm
? KHA-DA
? KHA-DA
? KHA-DA
RL.3.600 First Floor
RL.3.600 First Floor 3600
15
7500
3600
METAL ? ROOF
3600
3600
? KHA-DA
WALL SCONCE LIGHT
2140
600 360
1555
Phuong
RL.0.600 Ground Floor
RL.0.600 Ground Floor
0
0
600
600
1550
House 466 Ly Thai To St Nhon Trach, Dong Nai 830000
Eastern Elevation 1 : 50
2
ELEVATIONS
Western Elevation 1 : 50
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
NTM Checker
CD-200
90
Scale
1 : 50
11/21/2020 2:23:23 PM
1
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
7
6
5
4
3
2
1
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
20451 700
1200
4900
3300
4450
+10,816 mm
2300
3600
2'
15
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
METAL ? ROOF
Description
Date
15
METAL ? ROOF
? KHA-DA
1800
RL.6.900 Loft Floor
TIMBER BATTEN 50X100mm
3300
3300
6900
? KHA-DA
RL.3.600 First Floor
2800
3600
7500
3600
Phuong House
RL.0.600 Ground Floor
600
0
466 Ly Thai To St Nhon Trach, Dong Nai 830000
ELEVATIONS
Northern Elevation 1 : 50
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
NTM Checker
CD-201
91
Scale
1 : 50
11/21/2020 2:23:27 PM
1
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
1
2
3
4
3600
6
7
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
21150
2' 700
5
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
2300
4450
3300
4900
1200
700
+9,936 mm
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
+8,116 mm
21 LOFT 49.88 m² FN6026 SEAL
25 CONCRETE ROOF 65.76 m²
Description
Date
10/18/20 Updated Dimensions and Structural Solutions
1
RL.6.900 Loft Floor
3300
6900
14 BEDROOM 3 13.96 m² FN6026 SEAL
12 MASTER BEDROOM 22.85 m² FN6026 SEAL
15
RL.3.600 First Floor
7500
3600
3600
5 BEDROOM 1 10.26 m² FN6026 SEAL
3 KITCHEN 14.36 m² FN6026 SEAL
1 LIVING ROOM 28.45 m² FN6026 SEAL
4 ATRIUM 12.13 m² EGGER - EPL067
9 ENTRANCE 12.98 m² FN6026 SEAL
Phuong
RL.0.600 Ground Floor 0
600
10 BACKYARD 9.21 m²
2 DINING ROOM 25.23 m² FN6026 SEAL
House 466 Ly Thai To St Nhon Trach, Dong Nai 830000
SECTIONS
Section 1 1 : 50
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
NTM Checker
CD-300
92
Scale
1 : 50
11/21/2020 8:44:50 PM
1
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
C
B
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
A 8600
2400
6200 +10,816 mm
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
15
No.
2
Description
Date
10/18/20 Updated Dimensions and Structural Solutions
1
CD-500
+8,298 mm
1 CD-500
25 CONCRETE ROOF 65.76 m²
RL.6.900 Loft Floor
3300
3300
6900
22 CIRCULATION 3.85 m² EGGER - EPL067
20 STAIR 9.57 m² EGGER - EPL067
RL.3.600 First Floor
8 TERRACE 25.27 m² Skywood - DK14025R
3600
3600
7500
3600
4 ATRIUM 12.13 m² EGGER - EPL067
Phuong House
RL.0.600 Ground Floor
600
0
466 Ly Thai To St Nhon Trach, Dong Nai 830000
SECTIONS
Section 2 1 : 50
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
NTM Checker
CD-301
93
Scale
1 : 50
11/21/2020 8:44:52 PM
1
1 TOWEL ? RAIL
ROLL ? HOLDER
WT 5.0
3600
NGUYỄN THANH MAI
RAKED ? CEILING
412 120
860
600
RL.3.600 First Floor
3600 RAKED ? CEILING
1955
345
600
? WC
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
200
600
375 1350
300
375
375
1450
WB ?
400 100 300
MIXER ?
WB ?
750
? MIXER
RL.0.600 Ground Floor 0
422
413
400 50
800
RL.0.600 Ground Floor_Bathroom 1 1 : 25
2
160
150
1635
1
Bathroom 1_Elevation A
3
1 : 25
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
D G07
50
WT 5.0
? SHOWER
250
120
300
375 ROLL ? HOLDER
LED ? STRIP MIRROR ?
250
600
D G07
? WC
800
110
295
TOWEL ? RAIL
1100
815
WT 5.0
400 100 300
800 295
100
? WB
120
D G07
210
MIXER ?
1350
WT 2.0
350
3 7 BATHROOM 1 2.64 m² Terrazzo D6713
750
CD-400 2
450
1865
4
885
715
RL.0.600 Ground Floor
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
0
150
No.
1625
Description
Date
Bathroom 1_Elevation B 1 : 25
RL.3.600 First Floor
RL.3.600 First Floor
3600
3600
Phuong House
585
600
466 Ly Thai To St Nhon Trach, Dong Nai 830000
440
600 WATER ? TAP
WATER ? TAP
TOWEL ? RAIL
2020.01
Project number
ROLL ? HOLDER
Date
? WC
01/10/2020
800
SHOWER ?
1600
TOWEL ? RAIL
WET AREAS
1100
1100
ROBE ? HOOK
1450
D G07
ROBE ? HOOK
1450
600
? SHOWER W G03
1600
Drawn by RL.0.600 Ground Floor 0
1635
6
Interior Perspective - Bathroom 1
4
RL.0.600 Ground Floor
50
50
SHOWER ?
412
5
0
1630
Bathroom 1_Elevation C
5
1 : 25
94
Bathroom 1_Elevation D
Checked by
NTM Checker
CD-400
1 : 25 Scale
1 : 25
11/21/2020 2:23:42 PM
WT 11.0
ARCHITECTURAL GRADUATE
RL.3.600 First Floor
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
3
linkedin.com/in/thanh-mai-nguyen4b0a63182
1590
3 SHOWER ?
1205
WT 6.0
? UR
4740 795
650
WB ?
450
MIXER ?
4740
750
1526
814
600 TOWEL ? RAIL
1800
600
WT 2.0
RL.3.600 First Floor_Bathroom 2
80
2100
1800
2100
650
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
820
RL.3.600 First Floor
3600
3200
90
Bathroom 2_Elevation A
2
1 : 25
D F07
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
RL.3.600 First Floor
3
1240
3600
300
No.
Description
Date
Bathroom 2_Elevation B 1 : 25
1 : 25
3 4740
450
450
300
590
650
555 ROLL ? HOLDER
Bathroom 2_Elevation C
5
1 : 25
795
? WC
Bathroom 2_Elevation D 1 : 25
650
RL.3.600 First Floor 3600
375 1200
WET AREAS
? UR
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
6
NTM Checker
CD-401
Interior Perspective - Bathroom 2
95
Scale
1 : 25
11/21/2020 2:23:48 PM
785
466 Ly Thai To St Nhon Trach, Dong Nai 830000
400 250
3600
4
House
? MIXER
WB ?
50
750
610
800
650
RL.3.600 First Floor
700
Phuong
? MIRROR
100
300
2100
2100 1150
? UR
WC ?
115
LED ? STRIP
D F07
300
2700
1350
W F09
2100
1300
? SHOWER
TOWEL ? RAIL
300
375
450
600
1590
2700
1
D F07
250
210
A
55
? WB
375
375
? MIXER
50
940
D F07
3
2100
750
CD-401 2
W F09
TOWEL ? RAIL
750
450 4
2700
5
ROBE ? HOOK
300
WT 11.0
400 100 300
300
490
300
110
220 1590
15 BATHROOM 2 7.54 m² Terrazzo D6713
W F09
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
210
550
890
? WC
250
2' 210
7
ARCHITECTURAL GRADUATE
6
NGUYỄN THANH MAI
1595
6
WT 5.0
16 BATHROOM 3 7.60 m² Terrazzo D6713
3
500
? MIXER
450
BASIN ? 2
375
? UR
? WC
210
110
740
545
650
? UR
430
? WC
ROLL ? HOLDER
1665
? MIRROR
? MIXER
1150
W F01
TOWEL ? RAIL
300
490
300
1085
W F01
ROBE ? HOOK
5 TOWEL ? RAIL CD-402 2
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
LED ? STRIP
1350
4
? SHOWER
450
990
D F09
290 375
900
300
600
400 100 300
1050
210
900
linkedin.com/in/thanh-mai-nguyen4b0a63182
210 WT 11.0
1590
160
4780
2700
120
7
BASIN ? 2
RL.3.600 First Floor
A
RL.3.600 First Floor
3600
300
80
700
810
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
3600
300
5
550
650
WT 6.0
ROLL ? HOLDER
? SHOWER
? WC
545
450
450
290 NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
? UR
No.
2
1 : 25
Bathroom 3_Elevation A
3
1 : 25
Description
Date
Bathroom 3_Elevation B 1 : 25
6
7
600
1590
1500
House
50
1150
1600
466 Ly Thai To St Nhon Trach, Dong Nai 830000 RL.3.600 First Floor 3600
BASIN ? 2
WET AREAS
Bathroom 3_Elevation C
5
1 : 25
Bathroom 3_Elevation D 1 : 25
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
6
NTM Checker
CD-402
Interior Perspective - Bathroom 3
96
Scale
1 : 25
11/21/2020 2:23:55 PM
? MIXER
Phuong
800 2100
D F09
600
900
2100
2700
2700
375
350
50
750
400 100 300
RL.3.600 First Floor 3600
4
TOWEL ? RAIL W F01
300
1350
375
ROBE ? HOOK
250
1
RL.3.600 First Floor_Bathroom 3
50
545
700
700
700
656
110
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
TIMBER BATTEN 25X50mm
1500
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project. RL.3.600 First Floor 3600
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
Description
Date
50
1500
50x300x700 mm Timber Plate
700
50
110 50
920
50
1250
50x300x700 mm Timber Plate
700
10
250
1250
150 30
30
30
1050
300
9
Phuong
250 8
House
250 7
466 Ly Thai To St Nhon Trach, Dong Nai 830000
2360
250 6
250 1800
5
STAIRS
250
LED STRIP BELOW STAIR RAILING
4
250
2020.01
Project number
3
250
Date
30 150 30
2
250
Drawn by
Checked by
180
1
01/10/2020 NTM Checker
0
1
1 : 10
CD-410
3300
Stair Detail 01 4
97
5
Scale
1 : 10
11/21/2020 8:37:23 PM
RL.0.600 Ground Floor
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
1650
1650
linkedin.com/in/thanh-mai-nguyen4b0a63182
WALL SCONCE LIGHT 50
950
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
2461
20
RL.3.600 First Floor
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
3600
250
2000
19
250 18
250 17
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
250 16
250
4
15
250
No.
5
110
3300
Description
Date
110
14
250 13
250 1050
12
250 250 250 250 250 250 250 250 250
250 10
9
8
7
6
5
4
3
2
1
1
11
110
CD-410
1050
30
11
12
13
14
15
16
17
18
19
20 1
300
CD-411
250 250 250 250 250 250 250 250 250
A
1500
2
Phuong
RL.0.600 Ground Floor_Stair
House
1 : 25
466 Ly Thai To St Nhon Trach, Dong Nai 830000
STAIRS
2020.01
Project number
0
Date
01/10/2020 NTM
Drawn by
Checker
Checked by
4
1
5
CD-411
Stair Detail 02 1 : 10
98
Scale
As indicated
11/21/2020 2:23:56 PM
RL.0.600 Ground Floor
ARCHITECTURAL GRADUATE 1
2
NGUYỄN THANH MAI
3810 RL.3.600 First Floor
95
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
50
B
900
800
800
800
800
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
CD-430 2
2075
3
2400
3355
4
3025
linkedin.com/in/thanh-mai-nguyen4b0a63182
3600
210
3200
210
95
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No. 110
120
210
1970
1200
Description
Date
RL.0.600 Ground Floor 0
95
220 210
3200
95
3390
RL.0.600 Ground Floor_Bedroom 1
1
4
1 : 25
Bedroom 1_Elevation D 1 : 25
B 3025 900 900 RL.3.600 First Floor
3600
3600
400
1500
1200
900 RL.3.600 First Floor
300
Phuong
466 Ly Thai To St Nhon Trach, Dong Nai 830000 2100
2100
2400
2800
3600
House
BEDROOMS RL.0.600 Ground Floor
900
2075
RL.0.600 Ground Floor
0
0
220
1200
2020.01
Project number
1970 3390
Date
01/10/2020
Drawn by
Checked by
2
Bedroom 1_Elevation A
3
1 : 25
99
NTM Checker
Bedroom 1_Elevation B 1 : 25
CD-430 Scale
1 : 25
11/21/2020 2:23:57 PM
50
2'
ARCHITECTURAL GRADUATE
3
210
4740
360
NGUYỄN THANH MAI
210
2700
2100
C
B
B
linkedin.com/in/thanh-mai-nguyen4b0a63182
C
380
2400
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
2930
150
300
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
1800
2700
CD-431 2
2700
2400
4
1800
5
1350
3
110
3
4
1 : 25
Description
Date
Bedroom 2_Elevation C 1 : 25
4740
455
300
1800
No.
3600
710
3
2'
300
440
1350
1800
Phuong
2400
2700
1800 2000
2700
400
300
1800
Bedroom 2_Elevation A
2
1 : 25
260
870
2930
210
RL.3.600 First Floor_Bedroom 2
2400
600
House 600
1
2370
RL.3.600 First Floor
3600
300
2370
RL.3.600 First Floor
300
260
300
1800
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
600
260
600
980
B
466 Ly Thai To St Nhon Trach, Dong Nai 830000
RL.3.600 First Floor
300
RL.3.600 First Floor
3600
3600
155
2700
1890
4740
BEDROOMS
3
Bedroom 2_Elevation B
5
1 : 25
Bedroom 2_Elevation D 1 : 25
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
NTM Checker
CD-431
100
Scale
1 : 25
11/21/2020 2:23:58 PM
2930
300
920
680
210
2930
C
ARCHITECTURAL GRADUATE
1800
75
110
linkedin.com/in/thanh-mai-nguyen4b0a63182
2315
145
2700
100 Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
600
3
2700
2400
CD-432 2
2000
2400
2700
2400
RL.3.600 First Floor
3600
3600
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
2955
395
No.
365
Description
Date
2945 210
RL.3.600 First Floor_Bedroom 3
2
1 : 25
3
Bedroom 3_Elevation A
4
1 : 25
2'
2'
1800
300
300
Bedroom 3_Elevation C 1 : 25
3 440
4740
300
440
1800
260
2400
House
2700
1800
2700
1800
Phuong
600
466 Ly Thai To St Nhon Trach, Dong Nai 830000
600
1
4740
300
210
2400
220
150
RL.3.600 First Floor
RL.3.600 First Floor
300
RL.3.600 First Floor
3600
BEDROOMS
3600
300
2020.01
Project number
Date
3
Bedroom 3_Elevation B 1 : 25
5
Bedroom 3_Elevation D 1 : 25
01/10/2020
Drawn by
Checked by
NTM Checker
CD-432
101
Scale
1 : 25
11/21/2020 2:24:01 PM
2945
5 4
1800
400
260
210
650
110
NGUYỄN THANH MAI
3
300
2'
ARCHITECTURAL GRADUATE B
7 995
2000
685
linkedin.com/in/thanh-mai-nguyen4b0a63182
1010
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
900
900
2700
300
NGUYáť„N THANH MAI
2700
1500
1195
300
3600
1500
595
6
RL.3.600 First Floor
3290
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
RL.3.600 First Floor
3600
3600
300
2100
695
2000
685
360
600
50
No.
4690
Master Bedroom_Elevation A
2
3
1 : 25
1 : 25
235
3600
7 590
300
500
300
2400
6
300
655
Date
Master Bedroom_Elevation B
B 2100
Description
Phuong 2700
466 Ly Thai To St Nhon Trach, Dong Nai 830000
900
2400
2400
RL.3.600 First Floor
BEDROOMS RL.3.600 First Floor
3600
3600
4690
5390
2020.01
Project number
Date
01/10/2020
Drawn by
4
Master Bedroom_Elevation C
5
1 : 25
Master Bedroom_Elevation D
Checked by
NTM Checker
1 : 25
CD-433
102
Scale
1 : 25
11/21/2020 2:24:03 PM
2700
1500
House
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
6 210
210 800
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
210
3600
805
445
210
7
4690 710
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
2400
2980
B
Description
Date
CD-433 2
5390
5810
3600
5 4
455
210
210
1405
2100
2300
2300
110
3
110
3680 4
Phuong
210
House
CD-402 2
466 Ly Thai To St Nhon Trach, Dong Nai 830000
RL.3.600 First Floor_Master Bedroom
BEDROOMS
1 : 25
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
NTM Checker
CD-434
103
Scale
1 : 25
11/21/2020 2:24:04 PM
1
ARCHITECTURAL GRADUATE B
NGUYáť„N THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Roof Batten
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
900
50x100mm Glass Border Mullion
50 mm Metal Roof Sheeting with Thermal Insulation
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
45 50
100
90
Timber Fascia
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
250
250
Zincalume Box Gutter
50mm Raked Ceiling
Stainless Steel Plate Bolted connection
No.
Description
Date
100
Timber Frame Stailess Steel Nail Plate RL.6.900 Loft Floor 6900
Concrete Lintel
1
230
Section 2 - Callout 1
250
1:5
70
300
Seal Gap 50mm Metal Roof with Thermal Insulation
Phuong Over Flashing 100
150
House
Min
Apron Flashing Min
50x100mm Glass Border Mullion Timber Batten
466 Ly Thai To St Nhon Trach, Dong Nai 830000
100
Timber Ledger
DETAILS 45 50
2020.01
Project number
900 90
Date
01/10/2020
Drawn by
250
50mm Raked Ceiling
Checked by
NTM Checker
CD-500 2
Section 2 - Callout 2 1:5
104
15
180
15 Scale
1:5
11/21/2020 2:24:05 PM
Timber Frame
GROUND FLOOR
ARCHITECTURAL GRADUATE
2400 2100
NGUYáť„N THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
0
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
820 3600
820
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
D-G06
D-G04, D-G05 D-G07, D-G08
D-G01 D-G02 D-G03
820x2100mm 3600x2400mm
Manual Single Swing Aluminium Frame Door. G James 475 Series or Similar Approved
820x2100mm G James 475 Series or Similar Approved White painted Panels
Solid Core Door with painted finish to panels. NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
Clear Glass Panels
G James 475 Series or Similar Approved
To Ceiling
FIRST FLOOR No.
Description
Date
2100
2400 2100
0 160 700 75
3600
D-F01
820
D-F07 D-F09
3600x2400mm
2400
D-F02 D-F05 D-F06
D-F03
2400x2400mm
Clear Glass Panels
G James 475 Series or Similar Approved
820x2100mm G James 475 Series or Similar Approved
Manual Single Swing Aluminium Frame Door.
Clear Glass Panels
Solid Core Door with painted finish to panels.
G James 475 Series or Similar Approved
G James 475 Series or Similar Approved.
Clear Glass Panels
Phuong
LOFT FLOOR
House
2400 2100 466 Ly Thai To St Nhon Trach, Dong Nai 830000
DOORS
2020.01
Project number
Date
01/10/2020
Drawn by
1700
Checked by
D-L01
NTM Checker
1700x2100mm
CD-600
Manual Double Swing Aluminium Frame Door. Solid Core Door with painted finish to panels. G James 475 Series or Similar Approved.
105
Scale
1 : 50
11/21/2020 2:24:06 PM
0
GROUND FLOOR
ARCHITECTURAL GRADUATE NGUYáť„N THANH MAI
3600 linkedin.com/in/thanh-mai-nguyen4b0a63182
3200
2400 2100 1300
2400
800
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
0 800
900
800
800
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
800
W-G01
W-G02
1800x2800mm
3200x2400mm
Altair Louvre Window. 152mm Clear Glass Blades. Automatic Operation
Altair Louvre Window. 152mm Clear Glass Blades. Automatic Operation
600
W-G03 600x600mm
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
Manual Awning Aluminium Frame Window. G James 475 Series or Similar Approved. Frosted Glass Panels.
FIRST FLOOR
No.
Description
Date
3300
900
1200
2700
3300
2400
1500
1500
1800
1800
700
2700 2400 2100
800
600 0 800
2700
W-F06 W-F08
1350
3600
W-F07 W-F09
1350
640
600
W-F02
W-F01
W-F10
W-F03
3600x1500mm
1350x1500mm
600x2400mm
1800x3300mm
Manual Folding Aluminium Frame Window. G James 475 Series or Similar Approved. Clear Glass Panels.
Manual Folding Aluminium Frame Window. G James 475 Series or Similar Approved. Frosted Glass Panels.
Altair Louvre Window. 152mm Clear Glass Blades. Automatic Operation
Altair Louvre Window. 152mm Clear Glass Blades. Automatic Operation
W-F04 W-F05 2170x2700mm
2700x1800mm
1350x1800mm
Manual Folding Aluminium Frame Window. G James 475 Series or Similar Approved. Clear Glass Panels.
Manual Folding Aluminium Frame Window. G James 475 Series or Similar Approved. Frosted Glass Panels.
Phuong
Aluminium Frame Window. G James 475 Series or Similar Approved. Clear Glass Panels.
House 466 Ly Thai To St Nhon Trach, Dong Nai 830000
LOFT FLOOR
WINDOWS
2020.01
Project number
400
Date
0
01/10/2020
Drawn by
3400
600
W-L01
W-L02
3400x400mm
600x2100mm
Altair Louvre Window. 102mm Timber Blades. Automatic Operation
Altair Louvre Window. 152mm Clear Glass Blades. Automatic Operation
Checked by
NTM Checker
CD-610
106
Scale
1 : 50
11/21/2020 2:24:09 PM
2100
2100
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Number
Name
Area
Floor Finish
Percentage
Type Mark
Width
Material: Keynote
Material: Name
Material: Area
Material: Volume External face: Painted Finish
17 18 :2
WARDROBE 3 WARDROBE 2
10 BACKYARD 11 WARDROBE 1 25 CONCRETE ROOF :3 EGGER - EPL067 4 ATRIUM 20 STAIR 22 CIRCULATION EGGER - EPL067: 3 FN6026 SEAL 1 LIVING ROOM 2 DINING ROOM 3 KITCHEN 5 BEDROOM 1 6 LAUNDRY 9 ENTRANCE 12 MASTER BEDROOM 13 BEDROOM 2 14 BEDROOM 3 19 BALCONY 21 LOFT 23 CIRCULATION 24 CIRCULATION FN6026 SEAL: 13 Skywood - DK14025R 8 TERRACE Skywood - DK14025R: 1 Terrazzo D6713 7 BATHROOM 1 15 BATHROOM 2 16 BATHROOM 3 Terrazzo D6713: 3 Grand total: 25
1 m² 1 m² 2 m²
0.31% 0.31% 0.61%
9 m² 1 m² 66 m² 76 m²
2.49% 0.26% 17.78% 20.54%
12 m² 10 m² 4 m² 26 m² 28 m² 25 m² 14 m² 10 m² 5 m² 13 m² 23 m² 14 m² 14 m² 6 m² 50 m² 12 m² 9 m² 223 m²
EGGER - EPL067 EGGER - EPL067 EGGER - EPL067
FN6026 SEAL FN6026 SEAL FN6026 SEAL FN6026 SEAL FN6026 SEAL FN6026 SEAL FN6026 SEAL FN6026 SEAL FN6026 SEAL FN6026 SEAL FN6026 SEAL FN6026 SEAL FN6026 SEAL
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer.
WALL MATERIAL TAKEOFF
3.28% 2.59% 1.04% 6.91% 7.69% 6.82% 3.88% 2.77% 1.32% 3.51% 6.18% 3.76% 3.77% 1.50% 13.49% 3.14% 2.45% 60.30%
25 m² 25 m²
Skywood - DK14025R
6.83% 6.83%
3 m² 8 m² 8 m² 18 m² 370 m²
Terrazzo D6713 Terrazzo D6713 Terrazzo D6713
0.71% 2.04% 2.06% 4.81% 100.00%
BRICK STRUCTURE 210 WT 1.0 110 WT 2.0 210 WT 3.0 230 WT 4.0 220 WT 5.0 120 WT 6.0 220 WT 7.0 120 WT 9.0 320 WT 10.0 300 WT 11.0 210
BRICK STRUCTURE BRICK STRUCTURE BRICK STRUCTURE BRICK STRUCTURE BRICK STRUCTURE BRICK STRUCTURE BRICK STRUCTURE BRICK STRUCTURE BRICK STRUCTURE BRICK STRUCTURE BRICK STRUCTURE
Concrete - Polished Gris WT 11.0 210
Concrete Masonry Units WT 8.0 140
DA ONG TILE WT 3.0 WT 4.0 WT 7.0 WT 9.0
1.01 m³ 10.10 m³ 53.81 m³ 1.79 m³ 2.70 m³ 1.67 m³ 5.36 m³ 0.40 m³ 9.26 m³ 2.64 m³ 6.60 m³ 95.34 m³
Concrete - Polished Gris 37 m² 37 m²
0.55 m³ 0.55 m³
Concrete Masonry Units 103 m² 103 m²
14.48 m³ 14.48 m³
DA ONG TILE DA ONG TILE DA ONG TILE DA ONG TILE
0.20 m³ 0.15 m³ 0.05 m³ 0.69 m³ 1.08 m³
WT 1.0 110mm
External face: Painted Finish
WT 2.0 210mm Internal face: Painted Finish
Internal face: Painted Finish
External face: Da To Ong (Khatra)
External face: Da To Ong (Khatra)
WT 3.0 230mm
230 120 220 120 320
PAINTED MORTAR 210 WT 1.0 110 WT 2.0 210 WT 4.0 220 WT 5.0 120 WT 6.0 220 WT 7.0 120 WT 10.0 300 WT 11.0 210 Grand total: 171
KHA-DA KHA-DA KHA-DA KHA-DA
KHA-62003 KHA-62003
20 m² 16 m² 5 m² 73 m² 114 m²
DECOR TILE 100X300 DECOR TILE 100X300
21 m² 31 m² 51 m²
0.21 m³ 0.30 m³ 0.51 m³
MORTAR MORTAR MORTAR MORTAR MORTAR
20 m² 21 m² 31 m² 5 m² 73 m² 150 m²
0.30 m³ 0.31 m³ 0.45 m³ 0.07 m³ 1.03 m³ 2.16 m³
PAINTED MORTAR PAINTED MORTAR PAINTED MORTAR PAINTED MORTAR PAINTED MORTAR PAINTED MORTAR PAINTED MORTAR PAINTED MORTAR PAINTED MORTAR
11 m² 252 m² 630 m² 32 m² 21 m² 31 m² 5 m² 20 m² 37 m² 1038 m² 2119 m²
0.17 m³ 3.79 m³ 8.97 m³ 0.45 m³ 0.31 m³ 0.45 m³ 0.07 m³ 0.29 m³ 0.55 m³ 15.05 m³ 129.17 m³
The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
WT 4.0 220mm Internal face: Da To Ong (Khatra)
No.
Internal face: Painted Finish
Description
2
External face: Painted Finish
230 220 120 320
DECOR TILE 100X300 WT 5.0 120 WT 6.0 220
MORTAR WT 3.0 WT 5.0 WT 6.0 WT 7.0 WT 9.0
6 m² 126 m² 328 m² 10 m² 16 m² 21 m² 31 m² 5 m² 36 m² 10 m² 37 m² 625 m²
WT 5.0 110mm
Date
Updated 10/30/20 Wall Types
External face: Painted Finish
WT 6.0 210mm Internal face: 100x300 Tiles (Khatra)
Internal face: 100x300 Tiles (Khatra)
External face: Da To Ong (Khatra)
Internal face: Concrete Mansory Unit
WT 7.0 120mm
WT 8.0 140mm Internal face: Painted Finish
Internal face: Concrete Mansory Unit
External face: Da To Ong (Khatra)
Internal face: Painted Finish
WT 9.0 320mm
Phuong House
WT 10.0 300mm Internal face: Da To Ong (Khatra)
Internal face: Painted Finish
466 Ly Thai To St Nhon Trach, Dong Nai 830000
External face: Painted Finish
MATERIAL DATA WT 11.0 210mm Internal face: Poslished Concrete
Date
WALL TYPES 1 : 20
2020.01
Project number
01/10/2020
Drawn by
Checked by
NTM Checker
CD-700
107
Scale
1 : 20
11/21/2020 2:24:15 PM
FLOOR FINISH MATERIAL TAKEOFF
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
Description
Date
Phuong House 466 Ly Thai To St Nhon Trach, Dong Nai 830000
PERSPECTIVES
2020.01
Project number
01/10/2020
Drawn by
Checked by
SD-800
108
Scale
NTM Checker 11/21/2020 2:27:40 PM
Date
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
Description
Date
10/18/20 Updated Dimensions and Structural Solutions
1
Phuong House 466 Ly Thai To St Nhon Trach, Dong Nai 830000
PERSPECTIVES
2020.01
Project number
01/10/2020
Drawn by
Checked by
SD-801 1
Perspective 05
109
Scale
NTM Checker 11/21/2020 2:24:23 PM
Date
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
Description
1
Perspective 01
4
Date
10/18/20 Updated Dimensions and Structural Solutions
1
Perspective 03
Phuong House 466 Ly Thai To St Nhon Trach, Dong Nai 830000
PERSPECTIVES
2020.01
Project number
01/10/2020
Drawn by
Checked by
2
Perspective 02
3
Perspective 04
110
SD-802 Scale
NTM Checker 11/21/2020 2:24:39 PM
Date
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
Description
1
Interior Perspective - Dining Room 01
2
Date
10/18/20 Updated Dimensions and Structural Solutions
1
Interior Perspective - Dining Room 02
Phuong House 466 Ly Thai To St Nhon Trach, Dong Nai 830000
INTERIOR PERSPECTIVES 2020.01
Project number
01/10/2020
Drawn by
Checked by
SD-810 3
Interior Perspective - Living Room
111
Scale
NTM Checker 11/21/2020 2:24:45 PM
Date
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
Description
1
Interior Perspective - Small Bedroom 01
3
Date
10/18/20 Updated Dimensions and Structural Solutions
1
Interior Perspective - Small Bedroom 02
Phuong House 466 Ly Thai To St Nhon Trach, Dong Nai 830000
INTERIOR PERSPECTIVES 2020.01
Project number
01/10/2020
Drawn by
Checked by
2
Interior Perspective - Master Bedrrom 01
4
Interior Perspective - Master Bedroom 02
112
SD-811 Scale
NTM Checker 11/21/2020 2:24:48 PM
Date
ARCHITECTURAL GRADUATE NGUYỄN THANH MAI
linkedin.com/in/thanh-mai-nguyen4b0a63182
Drawings and Specifications as instruments of service are and shall remain the property of the Designer. They are not to be used on extensions of the project, or other projects, except by agreement in writing and appropriate compensation to the Designer. The General Contractor is responsible for confirming and correlating dimensions at the job site. The Designer will not be responsible for construction means, methods, techniques, sequences, or procedures, or for safety precautions and programs in connection with the project.
NOT FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION
No.
Description
Date
10/18/20 Updated Dimensions and Structural Solutions
1
Phuong House 466 Ly Thai To St Nhon Trach, Dong Nai 830000
2
INTERIOR PERSPECTIVES
Interior Perspective - Atrium 02
2020.01
Project number
Date
01/10/2020
Drawn by
Checked by
SD-812
113
Scale
NTM Checker 11/21/2020 2:24:50 PM
1
Interior Perspective - Atrium 01