Rescue and Emergency Breathing Systems Available for the FireHawk速 M7 and M7 Responder速 Air Masks
Because every life has a purpose...
MSA Rescue Belt II System
MSA's innovative device for emergency egress, the Rescue Belt II System, allows firefighters to rappel to safety should they become trapped in a building's upper level. MSA’s Rescue Belt II System meets NFPA 1983-2006 edition for Fire Service Life Safety Rope and System Components. Ergonomically-contoured Ara-Shield rescue belt pouch easily stores: • Choice of 50’ MSA aramid/nylon or FireTech 32 rescue rope. • Auto-locking Sterling F4 descender. • Choice of Crosby hook or carabiner.
Dual-action waist buckle
Self-adjusting waist belt Crosby hook
Quick-release reflective tab
Quick-release reflective tab Regulator holder
Low-profile D-ring
Ara-Shield pouch
Web management system
Sterling F4 descender
Sewn-in rope connection
Aramid/nylon rope
Within extreme conditions, this NFPA-compliant device provides all required equipment for rappelling; one belt fits all fire department members. Web management feature also integrates regulator holder for easy stowing of excess webbing. To initiate emergency egress, use right hand to pull knotted rope end forward to access Crosby hook and descender. Secure Crosby hook, engage descender and begin descent. Rescue Belt II System may be ordered as a FireHawk® M7 Air Mask option or as an individually-sold component for upgrade of your existing MSA FireHawk Air Mask. Rescue Belt II System is compatible with the MSA ExtendAire™ II and Quick-Fill® System.
Ordering Information P/N RESCUE BELT II SYSTEM
Description
10119369
Rescue Belt II System, FireHawk M7 Air Mask, 50-ft aramid/nylon rope, Crosby hook
10119370
Rescue Belt II System, FireHawk M7 Air Mask, 50-ft aramid/nylon rope, carabiner
10119391
Rescue Belt II System, FireHawk M7 Air Mask, 50-ft FireTech 32 rope, Crosby hook
10119392
Rescue Belt II System, FireHawk M7 Air Mask, 50-ft FireTech 32 rope, carabiner
10119393
Rescue Belt II System, AirHawk II/FireHawk Air Mask, 50-ft aramid/nylon rope, Crosby hook
10119394
Rescue Belt II System, AirHawk II/FireHawk Air Mask, 50-ft aramid/nylon rope, carabiner
10119395
Rescue Belt II System, AirHawk II/FireHawk Air Mask, 50-ft FireTech 32 rope, Crosby hook
10119396
Rescue Belt II System, AirHawk II/FireHawk Air Mask, 50-ft FireTech 32 rope, carabiner
www.MSAsafety.com
3
MSA Accountability System
Enhance Your Fireground Safety with MSA’s Accountability System! MSA’s Accountability System revolutionizes fireground safety by combining the latest computer software with a high-performance radio module and the field-proven technology of MSA’s FireHawk M7 Air Mask PASS.
MSA’s FireHawk M7 Accountability System consists of five main components:
FireHawk M7 Control Module Radio signal indicator
Pressure indicator (digital and icon)
Evacuation signal icon
FireHawk M7 Reader / ID Tag Writer
Battery status
Thermal indicator
• Provides graphical display of battery status, cylinder pressure, heat alarm, evacuation commands, radio connectivity, and service time remaining. • Measures and calculates your air consumption rate during the first three minutes of use. After initial calculation, service time remaining function updates every 30 seconds.
• Plugs into your computer’s USB port and downloads FireHawk M7 PASS device data. • Programs ID tags.
Accountability Base Station Incident Command Module • Transmits and receives radio signals to and from the FireHawk M7 PASS device via the license-free 902 – 928 MHz frequency band.
5
Reliable solid-state accelerometer detects firefighter motion • Offers sensitivity to motion and resistance to false alarms while meeting your job demands. • Resistant to typical wear associated with mechanical components.
ID Tag
FireHawk M7 Accountability Software
• Using a personalized ID tag, each firefighter can store his/her name, jump seat location, station number, and other information. • Your personal information then becomes part of the data logging record retrieved when all PASS device information is downloaded.
• Enables incident command to view each firefighter’s vital statistics on scene, such as PASS alarms, cylinder pressure, thermal alarms, battery status, time-remaining calculations, and evacuation acknowledgement. • Pulls critical information onscreen via pop-up windows.
www.MSAsafety.com
MSA Accountability System Accountability Software Screen q w e r t y u i o a s
Holding bin for arriving firefighters Task assignment Team name PAR timer Team detail area Radio contact indicators Evacuation buttons Low-battery indicator Thermal alarm PASS alarm Evacuation alarm indicator • Sent • Received • Acknowledged d Air time remaining calculator f Cylinder pressure display g SCBA detail area
u
r
e q
w
y
a o
i y
s
f d g
u
t
Ordering Information P/N MSA ACCOUNTABILITY SYSTEM
Description
10072240
Accountability Base Station Kit (includes software, antenna kit, USB cable, 8-24 volt power cable)
10083876
FireHawk M7 Air Mask Control Module Reader/ FireHawk M7 Air Mask ID Tag Writer
10083875
FireHawk M7 Air Mask ID tags
10075756
Antenna kit
10063880
USB cable
10049410
8-24 volt, power cable
10047342
Wall-mount power cable (not included in 10072240 kit)
See MSA FireHawk M7 Air Mask bulletin #0171-03-MC for complete product information.
MSA Quick-Fill System The Quick-Fill System allows for rapid transfer of air from a high-pressure source into a cylinder containing less pressure. This system can recharge SCBA cylinders under routine conditions without having to remove air masks and can even be used in atmospheres classified as IDLH (Immediately Dangerous to Life or Health). The MSA Quick-Fill System is the only NIOSH-certified emergency breathing option available, which allows every FireHawk M7 Air Mask to serve as a RIT unit for rapid intervention.
7
Ordering Information P/N MSA QUICK-FILL SYSTEM
10111642 485331 10111404
Description Quick-Fill Hose Kit in pouch, 3-ft emergency transfill hose Emergency transfill hose, less Kevlar pouch Replacement pouch for Quick-Fill or ExtendAire II Systems
485391
Male stainless steel quick-disconnect with SAE-10 thread, dust cover (also for use as a fitting for customized refilling systems)
485392
Female quick-disconnect with SAE-4 thread, complete with dust cover
www.MSAsafety.com
MSA ExtendAire Systems
MSA ExtendAire Systems MSA’s ExtendAire Systems allow firefighters to quickly and easily connect to and breathe from a fellow firefighter’s air cylinder. ExtendAire Systems are tightly integrated with SCBA to provide unrestricted mobility and easy access during critical situations.
MSA ExtendAire I System The ExtendAire I System is integrated to the Firehawk® MMR's second stage regulator’s intermediate pressure line. The system's 40-inch rescue hose between SCBA provides both firefighters with intermediate pressure air for emergency escape. P/N EXTENDAIRE I SYSTEM
Description
812958
ExtendAire System air-line hose with Foster plug
812973
40" rescue hose
10031798
ExtendAire System Upgrade Kit for threaded Firehawk MMR
10031797
ExtendAire System Upgrade Kit for quick-connect Firehawk MMR
MSA ExtendAire II System MSA’s ExtendAire II System offers an integrated rescue hose used with PR14™ First-Stage Regulator that features both male and female quick-connect fittings. System is stowed in a waist pouch that mounts on the carrier assembly and prevents snagging or accidental opening. ExtendAire II System also connects to the ExtendAire I System for additional system flexibility.
P/N EXTENDAIRE II SYSTEM
9
Description
10105883
ExtendAire II System Upgrade Kit for PR14 First-Stage Regulator
10111404
ExtendAire II System pouch
www.MSAsafety.com
MSA RescueAire速 II Portable Air-Supply System
Rapid Intervention Team Essentials MSA's RescueAire II Portable Air-Supply System provides easy-to-use, portable and compact emergency breathing air. Designed for Rapid Intervention Teams (RITs), the RescueAire II System is compatible with all FireHawk MMR Air Masks. Feature-packed system consists of flame-and heat-resistant carrying harness with adjustable Nomex/Kevlar shoulder strap, Audi-Larm™ Audible Alarm low-pressure warning device, pressure-reducing regulator, second-stage mask-mounted regulator, 36" Quick-Fill System EBS connection, and ExtendAire System EBS connection. RescueAire II Portable Air-Supply System is available in both low-pressure (2216 psig) and high-pressure (4500 psig) versions.
11
Ordering Information With L-30 cylinder RESCUEAIRE II PORTABLE AIR-SUPPLY SYSTEM
Less cylinder
Low-pressure (2216 psig)
10041196
10041198
RescueAire II System, Firehawk STC MMR
10041230
10041232
RescueAire II System, Firehawk PTC MMR
With H-60 cylinder
Less cylinder
High-pressure (4500 psig)
10100097
10100094
RescueAire II System w/Firehawk Responder MMR
10041195
10041197
RescueAire II System, Firehawk STC MMR
10041199
10041231
RescueAire II System, Firehawk PTC MMR
www.MSAsafety.com
MSA—The Safety Company Our business is safety. We’ve been the world's leading manufacturer of high-quality safety products since 1914. MSA products may be simple to use and maintain, but they’re also highly-sophisticated devices and protective gear — the result of countless R&D hours, relentless testing and an unwavering commitment to quality that saves lives and protects thousands of men and women each and every day. Many of our most popular products integrate multiple combinations of electronics, mechanical systems and advanced materials to ensure that users around the world remain protected in even the most hazardous of situations. Our dedication to safety has been the key to our impressive year-overyear growth. In eight of the past 10 years we’ve achieved record growth numbers, with annual revenues of more than $1 billion.
Our Mission MSA's mission is to see to it that men and women may work in safety and that they, their families and their communities may live in health throughout the world. MSA: Because every life has a purpose.
Note: This Bulletin contains only a general description of the products shown. While uses and performance capabilities are described, under no circumstances shall the products be used by untrained or unqualified individuals and not until the product instructions including any warnings or cautions provided have been thoroughly read and understood. Only they contain the complete and detailed information concerning proper use and care of these products.
ID 0100-32-MC / August 2012 © MSA 2012 Printed in U.S.A.
MSA Corporate Center 1000 Cranberry Woods Drive Cranberry Township, PA 16066 USA Phone 724-776-8600 www.MSAsafety.com
Offices and representatives worldwide For further information:
U.S. Customer Service Center Phone 1-800-MSA-2222 Fax 1-800-967-0398 MSA Canada Phone 1-800-672-2222 Fax 1-800-967-0398 MSA Mexico Phone 01 800 672 7222 Fax 52 - 44 2227 3943 MSA International Phone 724-776-8626 Toll Free 1-800-672-7777 Fax 724-741-1559