For more details visit www.marinemegastore.com or call 0871 8732404
EMAA Compact Air Conditioning Unit
For more details visit www.marinemegastore.com or call 0871 8732404
1
For more details visit www.marinemegastore.com or call 0871 8732404
Specifications are subject to alteration without notice
4600 GB 01.09
2
For more details visit www.marinemegastore.com or call 0871 8732404
2
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Contents
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 EMUV End wall outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 EMCF Bag filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 EMUE Air heater for hot water . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 EMUN Air cooler for chilled water . . . . . . . . . . . . . . . . . . . . . . . . . .9 EMUQ Steam humidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 EUMQ Spray humidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 EMUC Empty Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 EMCB Centrifugal fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 EMCT Belt drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 APAM, ATAM, ARAM Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Regoterm EMCR Energy recovery unit . . . . . . . . . . . . . . . . . . . . .14 REGOVENT EMUR Air distribution section . . . . . . . . . . . . . . . . . .15 DUOVENT EMUD Air distribution section . . . . . . . . . . . . . . . . . . .14 EMUS Cabin zone system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Fan chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Pressure drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Mollier chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Dimensions and weights Type 089 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32–37 Type 090 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38–43 Type 094 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44–49 Type 095 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50–55 Type 096 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56–61 Type 097 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62–67 Codification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72 Control system – ControlMaster STMD . . . . . . . . . . . . . . . . . . . . . . .76
4600 GB 01.09
3
For more details visit www.marinemegastore.com or call 0871 8732404
3
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Design
089
090
FC
FC
FC
FC
FC
FC
FC
FC
The EMAA is an air conditioning unit for marine applications from Fl채채kt Woods. It is developed from many years experience in the marine business, especially from the caribbean cruising market. Fl채kt Woods has been producing marine air conditioning units since 1937 and complies with all current world standards of today
General
The EMAA unit is a further development of the EU 2000 unit, which is designed and tested to the European CEN standards. The EMAA is furthermore designed to comply with the standards of US Public Health, the classification societies Lloyds, Norske Veritas, Bureau Veritas, Germanischer Lloyd and American Bureau of Shipping. The unit and its components are made
by Fl채kt woods companies to the Quality Assurance Standard ISO 9001 and the Environmental Standard ISO 14001. As the most important component of an air conditioning system, the air conditioning unit has a strong impact on the indoor climate and quality. That is why the EMAA is designed with hygienic requirements in mind. It is all about comfort. Day in, day out, year after year. Throughout a howling
4600 GB 01.09
4
For more details visit www.marinemegastore.com or call 0871 8732404
4
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Design
094
FC
FC
FC
FC
095 winter gale or a humid tropical heat wave. Relentlessly hour after hour, the Complete & Compact Trade Mark air handler from us supplies the interior of the ship with 28 tons of conditioned air to counteract extreme thermal loads and replace stale air. Economically and safely. It is packed with our latest air technology and comes with smart integration of electrical and automation equipment ready for hook-up. Its fans and other components are the most efficient we have ever made. The casing is tailored to match contemporary deck heights for compactness and high specific airflow capacity. It has a flush front face without annoying protrusions and is thoroughly factory tested before delivery. Installation and commissioning are plain sailing. Less space,
FC
FC
FC
FC
less noise, less co-ordination, less installation and less commissioning. But more air and more reliability. If you want to avoid hassle, while saving time and money, take a closer look at the Complete & Compact Trade Mark air handler from a world leader in HVAC systems. Product selection program
The Windows based selection program offers rapid selection to specific project requirements. The program also provides a detailed printout including a dimensioned sketch and a performance specification. The selection program now also features eCAD, which provides a link to most CAD programs.
4600 GB 01.09
5
For more details visit www.marinemegastore.com or call 0871 8732404
5
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Design
096
097
FC
FC
FC
FC
FC
FC
FC
FC
The EMAA is Eurovent certified
Certification involves testing a standard unit from our production in an independent laboratory appointed by EUROVENT.
thick panels are fixed. The inspection doors are mounted on sturdy, adjustable hinges and are provided whith a mechanically secured seal. Q- master air flow indicator
Steel profile frame and inspection doors
The hollow section steel profile frame is bolted at the corners to substantial corner pieces making a strong and robust structure to which the 50 mm
The EMAA fans can be equipped with the Q- master air flow indicator. The sensor and instrument have an overall accuracy of 7%. The air flow rate is indicated on a manometer.
4600 GB 01.09
6
For more details visit www.marinemegastore.com or call 0871 8732404
6
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Design
Design The inspection side may be on the right-hand or lefthand side, viewed in the direction of supply air flow.
Materials Unless otherwise stated, the components are made of galvanized or stainless sheet steel (AISI 304). As an option, every unit section can be delivered made of stainless sheet steel (AISI 316). Get in touch with Fl채kt Woods for further details.
Casing Each wall of the casing consists of a 50 mm thick mineral wool panel sandwiched between two sheet steel panels. The insulation material has been granted type approval and provides good thermal insulation. Its coefficient of heat transmission k is 1.2 W/(m2 째C), and the material also offers good sound attenuation and fire resistance. The casing is very sturdy and, in its standard design, can withstand an internal pressure or vacuum of up to 2500 Pa pressure differential. The maximum permissible air temperatures is +70째C. Quotations for casings suitable for higher temperatures can be submitted on request. Effective sealing strips are supplied for every joint. Moreover, all bottom panels are sealed and the casing is completely smooth on the inside and outside, which makes the unit hygienic and easy to clean.
4600 GB 01.09
7
For more details visit www.marinemegastore.com or call 0871 8732404
7
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMUV End wall outlet
With frame
Design The connection frame consists of an insulated, doubleskin wall, with an opening for duct connection. Intended for use on AHU combination 090. Accessories EMAZ-15 flexible connection EMAZ-16 duct connection piece EMAZ-17 counterflange EUAZ- 23 earthing cable (flexible connection) EMAZ-18 damper (actuator STMZ-27) EUVZ-01 lever actuator
Supply air outlet (without end wall) For duct connection direct to casing framework. Intended for use on AHU combination 089 and 090.
EMCF Bag filter
Design The filter consists of one or more disposable filter elements, with deep-folded basic or fine filter media. Filter classes as per EUROVENT 4/5 and as per ASHRAE Standard 52–76 (SMS 2289). EUROVENT 4/5
Bag filter class
Material 1)
EU 3 EU 5 EU 5 EU 6 EU 7
G 3 short F 5 short F 5 long F 6 long F 7 long
Flame-resistant polyester Flame-resistant polyester Flame-resistant polyester Flame-resistant polyester Flame-resistant polyester
The flame-resistant polyester filter material can be used at temperatures up to 100°C 2). The filter elements are replaceable. They are mounted on guide rails, and can therefore be easily withdrawn and inserted. The filter section can be ordered with internal components and guide rails of stainless steel. The guide rails with excenter-locking and seals on the filter provide good sealing. The outside of the casing is provided with tappings for connecting a manometer or a filter monitor. Bag filter frames are made of galvanized steel sheet. 1) As per DIN 53438, section 3, class F1. 2) The casing is designed for max. 70°C.
Accessories EMAZ-25 flexible connection (together with EMAZ-26) EMAZ-26 duct connection piece EUAZ-27 counter flange EMAZ-28 damper (together with EMAZ-26)
Accessories EUPZ-07 manometer Used for measuring the pressure drop across the filter. Pressure range: 0–400 Pa. EUPZ-08 filter monitor Provides remote indication when the pressure drop across the filter has exceeded the preset value (50–250 Pa). Mounting kit and connection components are supplied. EUAZ-01-1 inspection window EMAZ-09 bulkhead light. Replacement filter media EMAZ-03 filter element (complete filter) EU 3, EU 5 (F 5), EU 6 (F6), EU 7 (F85) replacement filters are delivered in sets for the appropriate unit size. 4600 GB 01.09
8
For more details visit www.marinemegastore.com or call 0871 8732404
8
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMUE Air heater for hot water
EMUN Air cooler for chilled water
Design Finned heat exchanger available in two capacity variants to cover the usual range of heating requirements. The heat exchanger consists of tubes and fins. The header tubes are made of copper and the water connections are made of brass. Water connections up to 50 mm (2") have male threads. The heat exchangers are equipped with plugged tappings for drainage and anti-freeze monitor. All sizes can be equipped with a Landis & Gyr type QAE 21.91 anti-freeze monitor. One side of the casing can be removed to enable the heat exchanger to be withdrawn.
Versions Heating medium Water Water
Max. working pressure, MPa Bar 1.6 1.6
16 16
Max. temp.,
Materials Tubes
Fins
Copper Copper
Aluminium Copper
째C 150 150
Heaters for higher working pressures and made of other materials are availabe to special order.
Accessorises EUAZ-40 threaded flange [for 15 mm (3/4"), 25 mm (1"), 32 mm (1 1/4") and 50 mm (2") tube]
Design Finned heat exchanger. Available in three capacity variants which cover the usual range of cooling requirements. The air cooler is available in two face area sizes with headers inside the casing. The air cooler consists of copper tubes and aluminium alt. copper fins. The header tubes are made of copper and the water connections are made of brass. Water connections have male threads. The heat exchangers are equipped with plugged tappings for drainage. If the air velocity is between 3 and 4 m/s, the air cooler version with droplet eliminator should be selected, in order to avoid condensate entrainment. The droplet eliminator is made of plastic fins in a stainless steel frame. The pressure drop across the droplet eliminator is low. The air cooler is equipped with a sloping stainless steel condensate insulated drain tray. The drain pipe from the drain tray runs through the casing on the inspection side of the unit and ensures reliable condensate drainage. One side of the casing can be removed to enable the finned element to be withdrawn. Operating pressure Up to 1.6 MPa Accessories EUAZ-40 threaded flange [for 25 mm (1"), 32 mm (1 1/4"), 50 mm (2") and 80 mm (3") tube] EUMZ-01 water trap (positive pressure max. 3000 Pa)
4600 GB 01.09
9
For more details visit www.marinemegastore.com or call 0871 8732404
9
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMUQ Steam humidifier
Orifice plate (steam) EMUN
EUM (N, P)
Female threads BSP 3/8" 100 200
Size aa = 12-18 Size aa = 06
Design The steam humidifier section is provided with steam lances. A drop tray of stainless steel discharges the condense water into the following cooling coil drain tray. The humidifier section must therefore be placed upstream a cooling coil. Dimensioning of orifice plate for steam The orifice plate for sizes 12 and 18 (two steam pipes) is to be dimensioned for half the air flow. Orifice plate for steam humudifier EMUQ giving a humidification corresponding to 3 grams of steam per kg air. The orifice plate no. refers to the code suffix for the diameter of the opening. Example: At an air flow of 2.8 m3/s and a steam pressure of 500 kPa, a no. 6 throttling flange should be selected. (See chart).
A
A
Size
A
B
weigh b=5
06 12 18
475 475 625
– 825 1025
7 12 15
Air flow, m3/h 2000
0,3
Air flow, 0,4 0,5
e
at
e
pl
ic
rif
3000 4000 5000
10 000
20 000
30 000
m3/s 1
2
3
4
5
6
1 2 3
O
4 5 6 7 8 9 150
200
300
400
500 600
800
Steam pressure, kPa
4600 GB 01.09
10
For more details visit www.marinemegastore.com or call 0871 8732404
10
B
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EUMQ Spray humidifier
EMUC Empty Section
Design The spray humidifier section is provided with flanges for connecting spray nozzels. A drop tray of stainless steel discharges the condense water into the following cooling coil drain tray. The humidifier section must therefore be placed upstream a cooling coil.
d=1
d=2
d=3
d=4
b=1
b=1
b=2
b=2
Design The empty section is available in different lengths, with or without inspection panel for positive pressure. The empty section is used: – as an intermediate section in units which include sections that may need additional access facilities for service, such as between two finned heat exchangers. – for accommodating components not included in the standard range.
Accessories EUAZ-01 inspection window (section length ≥ 300) EMAZ-09 bulkhead light
b=2
b=2
b=4
b=4
C
Female threads BSP 3/8 " (Spray) D
E
A
387 B
BSP 3/4" int.
100
100 200
200
Size
A
B
C
D
b=1
weight b=2
b=4
06 12 18
587 737 837
200 350 450
622 822 1002
452 587 702
6 7 8
7 8 9
9 10 11 11
4600 GB 01.09 For more details visit www.marinemegastore.com or call 0871 8732404
11
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMCB Centrifugal fan
Air flow control At higher rates of air flow, it is advisable to use inlet guide vane or frequency control for the EMCB fan. Inlet guide vane control is available for all unit sizes and consists of mechanically interconnected variable pitch guide vanes incorporated into the fan inlet. Frequency converter are available as alternative and has to be selected among our control components STM.
Design Double-inlet, belt-driven centrifugal fan. Within a given unit size, the choice is available between: – impeller with backward curved blades in normal or heavy-duty design – inlet guide vanes – fans of different sizes – air flow measuring device
Accessories Spare belts, set for EMCB (ordered with EMCT) EULZ-26 earthing cable (fan to casing) EUAZ-01 inspection window EMAZ-09 bulkhead light EMAZ-15 flexible connection (exhaust air outlet) EMAZ-16 connection piece (exhaust air outlet) EMAZ-17 counter flange (exhaust air outlet) EUAZ-23 earthing cable (for EMAZ-15)
Design particulars Designation
Impeller type (blades)
EMCB
Backward-curved Double inlet
Air flow range m3/s
Max. pressure, Pa
Max. efficiency, %
1-6,4
3000
80
To ensure good vibration isolation and structure-borne sound insulation, the fan and motor are mounted on a sturdy base frame which is effectively isolated from the casing by means of rubber anti-vibration mountings. The anti-vibration mountings are selected for induced and natural frequencies below 8 Hz. In order to avoid vibrations in the connected ducting or other sections of the unit, the fan outlet is connected to the casing by means of a flexible connection of fire-resistant material. The impeller shaft is mounted in ball bearings located at both inlets. The bearings are permanently lubricated. All bearings are secured to the shaft by means of circlips, ensuring a reliable joint and vibration- free operation.
4600 GB 01.09
12
For more details visit www.marinemegastore.com or call 0871 8732404
12
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMCT Belt drive
APAM, ATAM, ARAM Motor APAM, ATAM, ARAM motor
EMCT Belt drive
Design The belt drive consists of pulleys and one or more belts. The pulleys have a separate hub which allows for quick replacement of the rim if the fan speed should need to be altered.. The belt drives are designed for 50 Hz and 60 Hz motors.
The motor is mounted on slide rails for convenient adjustment of the belt tension. Single-speed or two-speed motors are available as standard. The motor has degree of protection IP 54. To ensure satisfactory cooling of the motor, the ambient temperature of the ventilation air should not exceed 40째C. Motors suitable for higher temperatures are available to special order.
4600 GB 01.09
13
For more details visit www.marinemegastore.com or call 0871 8732404
13
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Regoterm EMCR Energy recovery unit Drive unit The drive unit consists of a constant speed motor driving the rotor by means of a belt transmission. Rotor unit The rotor unit consists of the rotor, drive unit, purging sector, bearing mountings and the partitions with seals. Withdrawing the rotor for service requires a clear space at the inspection side corresponding to half the width of the REGOTERM casing. Purging of the rotor passages takes place in the purging sector. Purging minimises the carry-over of exhaust air to the supply air. An effective seal in the gap between the rotor and the casing minimises the leakage between the supply and exhaust air side. Design The energy recovery unit consists of a hygroscopic rotor, and a drive unit. The recovery unit can be installed for: – horizontal air flow – cooling and heat recovery
Accessories EUAZ-01 inspection window EUAZ-02-1 speed detector (initates an alarm automatically if the rotor should unintentionally stop.)
Rotor The recovery unit operates at a low pressure drop and at high and permanent temperature and moisture efficiencies – up to 85%. The rotor is rigidly mounted to the centre beam, but can be lifted inside the casing to facilitate service and cleaning. The rotor is made of aluminium. A hygroscopic rotor transfers both heat and moisture. The marine version of the rotor is suitable for operation in very hot and humid climates. The rotor: – is supplied with edge-reinforced face surfaces for corrosive environments – is designed for service at temperatures up to +50°C – is always equipped with purging sector – is always hygroscopic – has always constant speed – about 20 r/min. The recovery unit is made of stainless sheet steel. The drive motor is available classified as per Lloyd's Register of Shipping or Det norske Veritas.
Motor particulars
Temperature limitations imposed by the drive motor To safeguard efficient cooling if the drive motor is located inside the casing, the temperature in the area where the motor is located must never exceed +40°C.
EMCR code suffix aa -b-c
06, 12, 18
Motor size
Rated output, W
Rated current, A
-1-0
MT 71A 3 x 230/400 V, 50 Hz
90
0.95/ 0.55
-6-0
MT 71A 3 x 255/440 V, 60 Hz
110
0.95/ 0.55
-8-0
MT 71B 3 x 400/690 V, 50 Hz
120
0.65/ 0.4
-1-3
MT 71A 3 x 230/400 V, 50 Hz
80
0.87/ 0.5
-6-3
MT 71A 3 x 255/440 V, 60 Hz
100
0.87/ 0.5
-8-3
MT 71B 3 x 400/690 V, 50 Hz
100
0.6/ 0.35
-1-4
MT 71B 3 x 230/400 V, 50 Hz
100
1.05/ 0.6
-6-4
MT 71A 3 x 255/440 V, 60 Hz
100
0.87/ 0.5
-8-4
MT 71B 3 x 400/690 V, 50 Hz
100
0.6/ 0.35
4600 GB 01.09
14
For more details visit www.marinemegastore.com or call 0871 8732404
14
Classification
Unclassified
Lloyd's Register of Shipping
Det norske Veritas
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
REGOVENT EMUR Air distribution section
Design The air distributor is intended for the REGOVENT system. It is provided with a specific number of branches on the end wall or roof for connection to the MINIDUCT ducting system. The branches can be provided with non-return smoke dampers to air tightness class T5 (CEN 4). Actuator for non-return smoke dampers are to be dimensioned and orded together with electrical and control equipment. Min torque need: 2 Nm/branch. The EMUR air distribution section can be ordered for special duct connections on site.
DUOVENT EMUD Air distribution section
Design The air distributor is intended for the DUOVENT System and includes withdrawable air heater for hot water connection through the roof. The air distributor is provided with a specific number of branches on the end wall, for connection to the MINIDUCT ducting system, with one or two rows of branches on roof. All MINIDUCT * branches can be equipped with non-return smoke dampers to air tightness class T5. (CEN 4) Actuator for non-return smoke dampers are to be sized and orded together with electrical and control equipment. Min. torque required: 2 Nm/branch. * As alternative, rectangular duct connections. Dimensions see side 21. Accessories EUAZ-01 inspection window EUAZ-40 threaded flange 32 mm (1 1/4�)
4600 GB 01.09
15
For more details visit www.marinemegastore.com or call 0871 8732404
15
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMUS Cabin zone system
c=1
c=2
c=4
c=5 (aa=12,18)
EMCO Exhaust air section
c=3 (aa=12,18)
Design The air distributor is intended for the CABIN ZONE SYSTEM and includes withdrawable air heaters for hot water. Connections through the roof. The air distributor is provided with a specific number of branches on the end wall, for connection to the MINIDUCT ducting system, with one or two rows of branches on roof. All MINIDUCT branches can be equipped with non-return smoke dampers to air tightness class T5. (CEN 4) Actuator for non-return smoke dampers are to be sized and orded together with electrical and control equipment. Min. torque required: 2 Nm/branch Accessories EUAZ-01 inspection window EUAZ-40 threaded flange 25 mm (1�) or 32 mm (1 1/4�)
4600 GB 01.09
16
For more details visit www.marinemegastore.com or call 0871 8732404
16
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Accessories EUAZ-23 Earthing cable (flexible duct connection)
EUAZ-01 inspection window
EULZ-26 Earthing cable (flexible duct connection)
Can be factory-fitted to the unit sections tabulated below. Unit section
Quantity
EMCF bag filter EMCB fan EMUC empty section EMCR energy recovery unit EMUN cooling coil EMUE heating coil EMUD duvent section EMUS zone system section
1 1 1 1 1 1 1 1
EUAZ-35, Thermometer
EUAZ-40 Coil connection flange n × G dia. holes
EMAZ-06, Lifting tube, set
øE
øF
øD
H J
EMAZ-09 bulkhead light
EUAZ-14 Door lock, for one door
EMAZ-22-AHU packaging For truck or container transport.
For connection on the water, steam or condensate side. The flanges conform to Swedish Standard SMS 2035 (DIN 2635) alternatively to ANSI B 16,5 and are used for connecting the piping to the heat exchanger. Nom. pipe size mm
D
E
G
n
F
H
J
Wgt.,
15 25 32 50 80
95 115 140 165 200
65 85 100 125 160
14 14 18 18 18
4 4 4 4 8
1/2” 1” 1 1/4” 2” 3”
15 16 16 18 20
20 21 21 23 26
0.6 1.3 2.0 3.0 4.3
Nom. pipe size mm
D
E
G
n
F
H
J
Wgt.,
25 32 50 80
180 118 152 191
kg Connection SMS 2035 PN16 DIN 2635
kg 79 89 121 152
14 14 18 18
4 4 4 4
1” 1 1/4” 2” 3”
14 16 19 24
4600 GB 01.09
22 25 27 30
1.3 2.0 3.0 4.3
Connection 150Lb ANSI B 16.5
17
For more details visit www.marinemegastore.com or call 0871 8732404
17
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Accessories EMAZ-15-bb-c-d EMAZ-16-bb-c-d EMAZ-17-bb-c-d EMAZ-18-bb-c-d-e -15
-16
Flexible connection Duct connection piece Counterflange Damper (c=2)
-17
Airdistributor DUOVENT, rectangular connection
H2 x W
102
C
-18
H2 x W H
D PG Flange
240 50 125
W
H1 x W
+
215
H1 x W
+
107
107
c=1 Supply air in and outlet
c=2 Exhaust air inlet
bb
H mm 600 800 800
H mm 400 600 600
06 12 18
W mm 800 1100 1700
EMAZ-25-bb-2-d EMAZ-26-bb-2-d EMAZ-27-bb-2-d EMAZ-28-bb-c-d
c=3 Exhaust air fan outlet
W mm 800 1100 1700
H mm 500 600 600
EMAZ-16
W mm 500 600 600
50
Size
20 50
Flexible connection, (casing frame) Duct connection piece, (casingframe) Counterflange, (casingframe) Damper (casingframe)
Size bb
H 1
06 12 18
200 250 300
H 2 400 500 600
W
C
D
800 1100 1400
107 157 157
160 260 210
Flange dimensions 20 D
-25
-26
-28
-27
x200 H
H
B 12x19
50 50
125
W
240
PG Flange
W
EMAZ-26 Size
bb 06 12 18
Supply air casing outlet H mm 800 1000 1200
W mm 1200 1600 2000
50 20 50
Side W/H 200 250 300 400 500 600 800 1100 1400 1700
C
D
120 145 170 120 170 120 120 170 120 170
120 145 170 120 170 120 120 170 120 170
50
C
x200
215
20
4600 GB 01.09
18
For more details visit www.marinemegastore.com or call 0871 8732404
18
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Accessories EUPZ-07 manometer
EMAZ-14 base frame
100 CCC 80 A
EUPZ-08 filter monitor For remote indication that the pressure drop across the filter has exceeded the preset value (50–250 Pa). Mounting and connection components are supplied.
EUMZ-01 water trap For draining the condensate from air coolers or humidifiers. Intended for positive pressure of 3000 Pa.
16
Filter Size
A
06 12 18
1372 1772 2172
300-780 300-780 300-780
34 37 41
EMAZ-03 replacement filter set Filter class 03= short, class G3 (EU3), syntetic 05= short, class F5 (EU5), syntetic 15= long, class F5 (EU5), syntetic 16= long, class F6 (EU6), syntetic 17= long, class F7 (EU7), syntetic
Filter set size 06 12 18
EUPZ-19 Differential pressure gauge (type Dwyer Magnahelic)Recessed in inspection door
ccc Lenght Weight cm(step 10) approx kg/m
Nom filter sizes 600x600 600x300 1 1 2 2 3 3
EMAZ-04 air flowmeter sheet (set) For commissioning of air flow
INCHES OF WATER
.10
.20
.30
.40 50
EHELIC MAGNATED FOR CALIBR ON VERTICAL POSITI
EUVZ-01 Leaver actuator For external damper
Ă˜ 120
Filter set size 06 12 18
Nom filter sizes 600x600 600x300 1 1 2 2 3 3
4600 GB 01.09
19
For more details visit www.marinemegastore.com or call 0871 8732404
19
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Installation
Handling An air conditioning unit is normally delivered as a complete unit, mounted on the base frame EMAZ-14. Integrated lifting tubes EMAZ-06 must be used for lifting the unit.
Water trap EMAZ-01 Units with an air cooler require a min. of 240 mm mounting stand height or recess in deck to accommodate a water trap.
ø32 170
380 240
Service area Air conditioning units should be installed to facilitate inspection and service and for this, a 900 mm access space is required at the inspection side of the unit.
1404
222 Service area
900
Supporting distances
Max1500 Max1500 Max1500
Max distance between supports 1500 mm when installed on extra beams.
4600 GB 01.09
20
For more details visit www.marinemegastore.com or call 0871 8732404
20
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Fan charts – Explanation
80
max 3500
3000
81
70
15
3000
.998
2500
.995
2000
.988
1500
.976
60
2000 40
4
3
1
75
2500
1000
3500
η,%
3000 max 2800
2000
r/min kη
5
80
504
∆p t ,Pa
9
DIN 24166 Class 1
3500
14
1500 r/min LwA,dB 80
500
84
88
92
96
100
6
200 100 0.5
1
2 qv 6000
2000
3
1
10000
4
2
5
14000
6.5m 3 /s
6
18000
22000
m 3 /h
0.5 1
8
2
2
2000
2500
P M ,kW
P,kW
J = 0.31 kgm
1500
1
2
7
2800 3000 10 10 3500 r/min
600
18
16 pd
10
10
∆ pa
11
∆ p b + pd
12
∆ pg
13
20
40
100 60
50
100 50
200 80
120
200 100
300 200
300 350 160 400 300
200 500 400
Pa 240 Pa
600
Pa
500 Pa
LwAK = LwA + 2 dB
The EU fan charts on the following pages are valid for air with a density of 1.2 kg/m3. 1 = Air flow, m3/s (x-axis) 2 = Air flow,
m3/h
(x-axis)
12 = Pressure losses in inlet guide vanes for fans with backward-curved blades, ∆Pg, Pa.
3 = Total pressure, Pa (y-axis)
The appropriate pressure loss(es) above should be
4 = Fan speed, r/min (RPM)
added to external and internal pressure drops befo-
8 = Mass moment of inertia, kg/m2
re entering the fan charts. 13 = LwAK Sound power level for fan in casing, (A-weighted) 14 = Recommended working range of the fan 15 = Working range for reinforced fans
9 = Correction factor of efficiency, kη
10 = Recommended operating range
10 = Pressure losses to standardized outlet duct, ∆Pa, Pa
11 = Recommended operating range of a heavy-duty fan
5 = Fan efficiency, % 6 = Sound power level, dB (dotted) 7 = Fan shaft power, kW
11 = Pressure losses through distributor section, ∆Pb, Pa
4600 GB 01.09
21
For more details visit www.marinemegastore.com or call 0871 8732404
21
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMCB-06-2, fan DIN 24166 Class 2
2400 r/min 3600
2000
75
r/min kη
77
3400
404
75
η,%
3200
70
3000 2800 2400
50
2200 2000
∆p t ,Pa
40
1800
500
LwA,dB 80
1600
85
90
95
200 100 50 0.2
0.6
1 qv
2000
1
3400
.999
3200
.997
3000
.995
2800
.992
2600
.989
2400
.985
2200
.981
2000
.974
1800
.966
1600
.954
60
2600
1000
3600
1.4
4000
1.8
2.2
6000
2.6
8000
3.2m 3 /s
3
m 3 /h
10000
0.2 J = 0.14 kgm2
1600 2000
1
2200
1
2400 2600
2
2800
2
3000 3400
4
3600 r/min
4
500
3
3200
3
5
5 pd
∆ pa
10
30 10
50
20
∆ p b + pd
40
∆ pg
50
100 40
60
100 100
200 80
120
200 200
Pa
300 300
240Pa
400
Pa Pa
LwAK = LwA + 2 dB
4600 GB 01.09
22
For more details visit www.marinemegastore.com or call 0871 8732404
22
P M ,kW
P,kW
1800
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMCB-06-3, fan DIN 24166 Class 1
4000
r/min kη
r/min max 4000
75
75.5
3000
360 x 455
1
3500
.998
3000
.994
2500
.989
η,%
3500 max 3300 2000
4000
75 70
3000
60
2500 1000
40
∆p t ,Pa
2000 500
1500
LwA,dB 84
88
92
100
96
2000 .979
200
1500 .958
100
P,kW
1
1
2
2000
4000
qv 6000
3 8000
4
5.5m 3 /s
5
10000 12000 14000 16000 18000
1500
JJ== 0.24 kgm2
m 3 /h 1
2000 2
2
2500 3000
4
6
3300 3500 8 4000 r/min
500
12
12 pd
20
∆ pa
40 30 40
∆ p b + pd ∆ pg
100
60
200
300
60 80 100
400
200
500 300
600
14 Pa
400
Pa
100
200
300
400
600
800
1000
Pa
100
200
300
400
600
800
1000
Pa
LwAK = LwA + 2 dB
4600 GB 01.09
23
For more details visit www.marinemegastore.com or call 0871 8732404
23
P M ,kW
0.5
0.5
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMCB-12-2, fan DIN 24166 Class 1
3500
80
max 3500
3000
r/min kη
81 80
504
max 2800
70
2500
3000
.998
2500
.995
2000
.988
1500
.976
60
2000
1000
1
75
3000 2000
3500
η,%
∆p t ,Pa
40 500
1500 r/min LwA,dB 80
84
88
92
96
100
200 100 0.5
1
2
3
qv 6000
2000
4
10000
5
14000
6.5m 3 /s
6
18000
22000
m 3 /h
0.5 1 2
2
2000
2500 2800 3000 10 10 3500 r/min
600
18
16 pd
10
20
40
100
∆ pa ∆ p b + pd ∆ pg
60 50
100 50
200 80
120
200 100
300 200
300 350 160 400 300
200 500
Pa 240 Pa
600
400
Pa
500 Pa
LwAK = LwA + 2 dB
4600 GB 01.09
24
For more details visit www.marinemegastore.com or call 0871 8732404
24
P M ,kW
P,kW
J = 0.31 kgm2
1500
1
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMCB-12-3, EMCB18-2, fan DIN 24166 Class 1
4000 r/min max 3200 3000
570
80
r/min kη
81
3000
η,%
2800
60
2000 1800 1600
∆p t ,Pa
800
3000
.999
2800
.999
2600
.998
2400
.996
2200
.995
2000
.993
1800
.99
1600
.986
1400
.981
70
2200
1000
1
75
2600 max 2500 2400
2000
3200
80
40
1400
600
LwA,dB 86
400
90
94
98
102
200 100 50 1
2
3
4
5
qv 10000
6
7
8.5m 3 /s
8
30000 m 3 /h
20000
1 1400 2
J = 0.60 kgm2
2 P M ,kW
P,kW
1600 1800 2000 2200 2400 2500 2600
10
10
2800 3000
600
3200 r/min
20 pd
20
60
∆ pa ∆ p b + pd ∆ pg
20 60
20 22
100
200
40 100
50
60 200
100
80 300
300
400
Pa
100 120 140 160
Pa
400
200
500 300
600
700 Pa
400
Pa
LwAK = LwA + 2 dB
4600 GB 01.09
25
For more details visit www.marinemegastore.com or call 0871 8732404
25
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMCB-18-3, fan DIN 24166 Class 1
4000 r/min max 2800
640
3000
r/min kη
80
82
η,% 80
2600 2400
75
2200 max 2100 2000
2000
60
1600 1400
∆p t ,Pa
1
2600
.999
2400
.999
2200
.998
2000
.997
1800
.995
1600
.993
1400
.99
1200
.986
1000
.978
70
1800 1000
2800
40
1200 500
LwA,dB 80
1000
85
90
95
100
200 100 50 1
3 qv 10000
5
7 20000
11 m 3 /s
9
m 3 /h
30000
0.5 1
1000 J = 1.00 kgm2
2
1.5 2 P M ,kW
P,kW
1200 1400 1600 1800 2000 2100 2200
10
10
2400 2600
800
20
2800 r/min
20 25 p d 10
∆ pa
20
40
60 80 100
20
40
∆ p b + pd 40 ∆ pg
20
25
60
100 40
60
200
80
120
300 160
30 400 450 Pa
200
300
Pa
200
300
400
500
600 700 Pa
80 100
150
200
250
300
Pa
LwAK = LwA + 2 dB
4600 GB 01.09
26
For more details visit www.marinemegastore.com or call 0871 8732404
26
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
PRESSURE DROP – SIZE 06 Air flow, m3/s Air flow, m3/h
Pressure drop, Pa
1.0 3600
1.2 4320
1.4 5040
1.6 5760
1.8 6480
2.0 7200
2.1 7560
2.2 7920
Unit section
Designation Remarks
Pressure drop ∆p, Pa
Short bag filter
EMCF
Filter class
EU3, G3 EU5, F5
70 120
75 140
90 160
100 185
120 215
140 240
150 255
160 265
Long bag filter
EMCF
Filter class
EU5, F5 EU6, F6 EU7, F7
105 125 145
115 140 165
130 155 180
140 170 200
155 185 220
170 205 240
180 215 250
190 225 260
Air heater, hot water
EMUE
Capacity variant
1 2
15 15
20 25
25 30
35 35
40 45
50 55
55 60
60 65
Air cooler, chilled water
EMUN 2.5 mm fin pitch
06 08 10
85 115 140
115 155 195
150 200 250
190 250 315
135 180 225
165 215 270
180 235 290
190 255 315
Small face area: 3 m/s vid 1.4 m3/s
Large face area: 3 m/s vid 2.0 m3/s
10
15
20
25
30
35
40
45
REGOTERM
EMCR
90
110
130
145
165
185
190
190
Air distributor
EULZ-13
Fan size
15 15
20 20
30 25
35 35
45 45
55 55
70 65
80 75
DUOVENT Air distribution section
EMUD
2.0 mm fin pitch Air heater, hot water
0.40 1440 50
0.45 1620 60
0.50 1800 75
0.55 1980 85
0.60 0.65 2160 2340 100 110
0.70 2520 125
0.75 2700 140
Small face area Capacity variant
Droplet eliminator
2 3 Air flow m3/s Air flow m3/h b = 1, 3
Large face area
Duct connection
Air velocity, duct, m/s Pressure drop, Pa
3 10
4 15
5 20
6 30
7 40
8 50
9 60
10 70
Air velocity, duct, m/s Pressure drop, Pa
3 10
4 15
5 20
6 30
7 40
8 50
9 60
10 70
REGOVENT Air distribution section
EMUR
Duct connection
Exhaust air section
EMUO
Duct connection
0
0
0
5
10
15
20
25
Zone section
EMUS
Dut connection
20
30
35
45
50
55
60
70
4600 GB 01.09
27
For more details visit www.marinemegastore.com or call 0871 8732404
27
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
PRESSURE DROP – SIZE 12 Air flow, m3/s Air flow, m3/h
Pressure drop, Pa
2.2 7920
2.6 9360
3.0 10800
3.4 3.8 4.2 4.4 12240 13680 15120 15840
Unit section
Designation Remarks
Short bag filter
EMCF
Filter class
EU3, G3 EU5, F5
70 130
80 150
Pressure drop ∆p, Pa 95 175
110 200
130 225
150 255
160 285
Long bag filter
EMCF
Filter class
EU5, F5 EU6, F6 EU7, F7
110 130 155
120 145 170
135 160 190
150 175 210
165 195 230
180 215 250
195 235 270
Air heater, hot water
EMUE
Capacity variant
1 2
10 12
10 15
15 20
20 25
25 30
35 35
40 40
Small face area Air cooler, chilled water
EMUN 2.5 mm fin pitch
Capacity variant
Small face area: 3 m/s vid 3.1 m3/s
Large face area: 3 m/s vid 4.0 m3/s
REGOTERM
EMCR
Air distributor
EULZ-13
Fan size
DUOVENT Air distribution section
EMUD
2.0 mm fin pitch Air heater, hot water
06 08 10 Droplet eliminator
2 3 Air flow m3/s Air flow m3/h b = 1, 3
105 135 170
135 180 225
175 230 285
Large face area 215 285 355
185 250 310
205 270 330
220 290 365
10
20
30
40
50
60
70
110
135
155
175
200
220
250
20 15
30 20
40 30
50 35
60 45
75 55
90 70
0.9 3240 70
1.0 3600 85
1.1 3960 100
1.2 1.3 4320 4680 120 150
1.4 5040 175
1.5 5400 190
Duct connection
Air velocity, duct, m/s Pressure drop, Pa
4 15
5 20
6 30
7 40
8 50
9 60
10 70
EMUR
Duct connection
Air velocity, duct, m/s Pressure drop, Pa
4 15
5 20
6 30
7 40
8 50
9 60
10 70
Exhaust air section
EMUO
Duct connection
0
0
0
5
10
15
20
Zone section
EMUS
Dut connection
35
40
50
60
70
80
90
REGOVENT Air distribution section
4600 GB 01.09
28
For more details visit www.marinemegastore.com or call 0871 8732404
28
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
PRESSURE DROP – SIZE 18 Air flow, m3/s Air flow, m3/h
Pressure drop, Pa
3.9 14040
4.3 4.7 15480 16920
5.1 5.5 5.9 6.2 18360 19800 21240 22320
Unit section
Designation Remarks
Pressure drop ∆p, Pa
Short bag filter
EMCF
Filter class
EU3, G3 EU5, F5
80 140
90 155
100 165
110 180
120 190
135 205
150 220
Long bag filter
EMCF
Filter class
EU5, F5 EU6, F6 EU7, F7
120 145 165
130 155 175
140 165 180
150 175 190
160 190 205
170 200 220
180 215 235
Air heater, hot water
EMUE
Capacity variant
1 2
20 25
25 30
30 35
35 40
40 45
45 50
50 55
Large face area
Small face area Air cooler, chilled water
EMUN 2.5 mm fin pitch
Capacity variant
Small face area: 3 m/s vid 4.7 m3/s
Large face area: 3 m/s vid 5.8 m3/s
REGOTERM
EMCR
Air distributor
EULZ-13
Fan size
DUOVENT Air distribution section
EMUD
2.0 mm fin pitch Air heater, hot water
06 08 10 Droplet eliminator
2 3 Air flow m3/s Air flow m3/h b = 1, 3
130 170 215
150 200 255
175 235 295
205 270 335
230 305 380
260 345 430
290 385 480
30
35
45
50
60
70
80
140
155
170
185
200
220
235
25 25
35 30
40 35
50 45
60 55
70 65
85 75
1.3 4680 110
1.45 5220 80
1.6 5760 100
1.7 1.85 6120 6660 120 140
2.0 7200 160
2.1 7560 180
Duct connection
Air velocity, duct, m/s Pressure drop, Pa
4 15
5 20
6 30
7 40
8 50
9 60
10 70
Air velocity, duct, m/s Pressure drop, Pa
4 15
5 20
6 30
7 40
8 50
9 60
10 70
REGOVENT Air distribution section
EMUR
Duct connection
Exhaust air section
EMUO
Duct connection
30
35
45
50
55
60
70
Zone section
EMUS
Dut connection
30
35
45
50
55
60
70
4600 GB 01.09
29
For more details visit www.marinemegastore.com or call 0871 8732404
29
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
MOLLIER CHART Air temperature –25 to +40°C x 0,010
0,005
0,000 t 0,1 0
h kJ x kg
0,015
ϕ=
°C
0, 20
35
0, 30
30
40
0,
50
25
0,
70
60
0
15
14
12
40
11
15
13
50
45
ϕ
0 0,9 ,00 =1
16
0 55
0,8
20
60
0,7
65
0,
10
/k
kJ
g
35 9
kg al/ kc
8
30
10 25
7 6
20
5
5
15 4
°
15
10
0
3 2
5
°
10 er b et ul r om m t b ete ulb er we rmom ed b tt t vå te oa
-5 h
gd ela isb
1
= -5
-10
5°
-c ice
0
0
-1
-1
2,0
tv
=
± 0° 1,5
- 5°
0 -2
h = entalpi per kgSYMBOLS torr luft, kJ/kg, kcal/kg hx == enthalpy per kg of kg drytorr air,luft, kg/kg vatteninnehåll per kJ/kg, kcal/kg
0°
-15
-1
-1
1,0 kPa
°
- 15
5
2,5
ϕ = relativ fuktighet
x = moisture content per kg dry air, kg/kg t = torra termometerns temperatur, C°
ϕ = relative humidity
tv = våta termometerns temperatur, C°
-20
0,5
t = dry-bulb temperature, °C Diagrammet hänfört till
t v = wet-bulb temperature, °C
barometertryck = 760 mm Hg = 101,3 kPa
-25
0
This chart refers to a barometric pressure of 760 mm Hg = 101.3 kPa. 4600 GB 01.09
30
For more details visit www.marinemegastore.com or call 0871 8732404
30
kg kg
0,000
14
50 12
10
40
35
8
0
10 00
30
25
6
20
15
ulb ulb ted b b t a we e-co 0 ic 0 5 = h
For more details visit www.marinemegastore.com or call 0871 8732404
-5
4600 GB 01.09
31
-1
0
-2
-1
5
-2
0
0
45 00
10
150 kJ/k 0 g
1,40 -20° 60°
1,30
1,20
1,10
0
0,2
-10° 50°
0° 40°
10° 30°
32
-25
60 65
0,5
l/kg
1,0
kca
° -15
55 ,00
20° 20°
34
-20
16
1,5 kPa
/kg
-5°
kJ
° -10
00 70
-15
18
tv
75
SYMBOLS
90
h = enthalpy pr kg of dry air, kJ/kg, kcal/kg x = moisture content per kg dry air, kg/kg ϕ = relative humidity t = dry-bulb temperature, °C tv = wet-bulb temperature, °C ρ = kg dry air/m3 moist air t ρ = kg moist air/m3 moist air = ρt (1 + x) This chart refers tp a barometric pressure ρt ρ of 760 mm Hg = 101.3 kPa.
24
-10
20
2,0
00 80
5°
85
° =0
22
2,5
95
-5
0
3,0
10
10°
5
4
26
0
10
3,5
0
15°
11 0
28
5
5
tv
11
ρ
0
=1
30
ϕ
0
0,6
12
1,00
13
4,0 kPa
5
0° =2
30° 10°
6,5 kPa
36
4,5
0
6,0
0,045
0 15
10
13
5,0
14 35°
5
5,5
0,040
14
30°
0,035
5
25°
0,030
15 40° 0°
ρt
7,0
38
0 0,6 0 0,7 0 0,8 0,90 0 ,0 ϕ=1
50 0 kJ 0 /kg 0,025
0
15
0
0
700
0,5
55 0,020
40°
0,050
50° -10°
0,0
35
1,30
1,20
1,10
2000
5
10
15
20
25
1,00 30
1,40 60° -20°
0
0 0,4 0 2 , 0
0,90
40
45
50
kg kg
100
200
300
400
500
600
700
mmvp kp/m2 800
0,055 x
mm Hg 55
kg/m3 0,80
7,5
5
20
,40
0
0 0
800
0,3
0,015
16
25
20
0,
0,010
00 J/kg k
40
30
0,005
40
0
35
40
45
50
55
t °C
0
0,1
ϕ=
kJ/kg
h kJ kg
00
17
=1 ,00
17
ϕ
0
60 0,8 0
∞+ 18
0,
45
2500
3000 kJ/kg
0 350
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA Air conditioning unit MOLLIER CHART Air temperature –25 to +55°C
5 12
60
00
−∞
31
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–440–089–1, left View A-A
DN 50 100
52 7,5 kw
200
GJ 031
50 Ø 1150
View C-C
205 465
670 50
132M
10 kw Con- Control GJ 034 verter unit 160M unit
50 974
30
1574
770 52
52
700
300
300
900
400
1104
600
400
900
100
52
3304 4408
1404
222 Service area
View B-B
900
View A-A
View C-C
696
500
187
800
417
87
ECMB -06-2
404 500
400 70 700
966 600
100
137 417
800
187
Motor limitation Max Motor EMCB IEC 06-2 132M 06-3 160M
L
W
W
250
1000
87 800 87
50
80
1200 1372
102
Weight standard example: Max demensions L W – 264 602 223
EMCA CASING (L=3304) EMCF filter (supply+exhaust) EMCB/T size 2, 132M iron (exahust) 60+72= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=1000) EMCO exhaust air section EMCB/T size 3, 160M iron (supply) 95+115= EMUA casing (L=1104) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMAZ–14 base frame (L=4400) EMAA–06–440–089–1 WEIGHT KG
449 33 132 126 106 2 210 82 0 206 161 1509
4600 GB 01.09
32 For more details visit www.marinemegastore.com or call 0871 8732404
32
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–440–089–1, right View B-B
7,5 kw
1574
200
GJ 031
50
132M
Ø 1150
670 50
View C-C
465 205
52
DN 50 100
10 kw Control ConGJ 034 verter unit unit 160M
30
770
50 974
52 100
52
900
400
600
400
900
300
300
3304
700
52
1104
4408
1404
222 Service area
900
View B-B
View C-C 500
VIEW A-A
696 417
500
800
87
ECMB -06-2
404
187
400 70
966
87
700 600
800 100
137
87 187
800
417
50
1000
250
102
1200 1372 80
Additional lenghts and weights Size 06 Lenght Weight Weight
Casing Kg/m EMCC excl. EMCA EMUA converter Al,6r – – – 400 0 107 75 – 55 – 93 Small face area – 108
Al,8r 0 – 74 – 93
EMUN cooler Al,10r Cu,6r Cu,8r Cu,10r 0 0 0 0 – 54 – 36 0 36 – 78 – 66 – 39 – 11 = Choice in example
4600 GB 01.09
33 For more details visit www.marinemegastore.com or call 0871 8732404
33
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–470–089–1, left View A-A 205 465 52 50 11 kw
DN80
100
Ø 1580
View C-C
300
970 160M
30 2174 50
22 kw
GJ 045 1274 50
GJ 040
160M
Converter Control unit unit
1070
180M
52 300
300 300
52
1100
400
500
1104
100 52
1100
400
3604 4708
1804
203 Service area
800
View B-B View C-C 894
167
600
504
800
1000
1320
100 137 250
1400
137
1000
137 80
50
187 102
Motor limitation Max Motor EMCB IEC 12-2 160L 12-3 180M
L
W
W
View A-A 517
600 70
1100
1100
600
ECMB -12-02
517
187
1772 1600
Weight standard example: Max demensions L W – 343 – 229
EMCA casing (L=3604) 686 EMCF filter (supply+exhaust) 43 EMCB/T size 2, 160L iron (exahust) 106+127= 233 EMCR rotor 204 EMCC cubicle+(cable, actuators, conv. L=900) 119 EMCO exhaust air section 3 EMCB/T size 3, 180M iron (supply) 142+178= 320 EMUA casing (L=1104) 106 EMUC emty section (L=300) 0 EMUN cooling sect. (Cu/Cu, 8r, max face) 360 EMAZ–14 base frame (L=4700) 180 EMAA–12–470–089–1 WEIGHT KG 2254
4600 GB 01.09
34 For more details visit www.marinemegastore.com or call 0871 8732404
34
102
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–470–089–1, right View B-B 465 205 52 50 11 kw
View C-C
160M
Ø 1580
GJ 040 970
300
2174 30 50
22 kw ConControl verter unit unit
1070
DN80
100
GJ 045 1274 50
M061
180M
52 300
100 52
1100
300 400
500
400
1100
52
300
3604
1104 4708
1804
203 Service area
800
View B-B
View C-C 600
600
1320
VIEW A-A 517
894
1100
187
167
600
ECMB -12-02
504
70
137
1000
1000
800 100
137
137 187
1100
517
50
1400
250
80 1772 1600
102
102
Additional lenghts and weights Size 12 Lenght Weight Weight
Casing Kg/m EMCC EMUN cooler excl. EMCA EMUA converter Al,6r Al,8r Al,10r Cu,6r – – – 400 0 0 0 0 143 97 – 56 – 173 – 137 – 103 – 68 Small face area – 204 – 177 – 151 – 127
Cu,8r Cu,10r 0 0 0 64 – 77 – 29
= Choice in example
4600 GB 01.09
35 For more details visit www.marinemegastore.com or call 0871 8732404
35
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–490–089–1, left View A-A
DN80
100
52 300
22kw
50
GJ 045
Ø 1880
View C-C
205 465
50
970 180M
2174 30 50 1070
30kw GJ 050 GJ 045
1374
160M 160M
200L
Converter Control unit unit
52 100 400
400 700
52
300
1200
400
1104
500
400
1200
52
3804 4908
2204
203
800
Service area
View B-B
View C-C
1112
View A-A
600
187
1700
317
87
ECMB -18-2
570 600
600
1 70
1405
1100
87
1200
800 100
137 317
1700
250
1800
87 80
50
2172
187 102
Motor limitation Max Motor EMCB IEC 18-2 180M 18-3 200M
L
W
W
2000
Weight standard example: Max demensions L W – 329 – 332
EMCA casing (L=3804) EMCF filter (supply+exhaust) EMCB/T size 2, 180M iron (exahust) 142+178= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=900) EMCO exhaust air section EMCB/T size 3, 180L iron (supply) 170+250= EMUA casing (L=1104) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMAZ–14 base frame (L=4900) EMAA–18–490–089–1 WEIGHT KG
806 57 320 204 119 4 420 123 0 483 203 2739
4600 GB 01.09
36 For more details visit www.marinemegastore.com or call 0871 8732404
36
102
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–490–089–1, right View B-B
300
22kw
50
Ø 1880
GJ 045 970 180M
View C-C
465 205
52
DN80
100
2174
30 50 1070
50
30kw GJ 050 540 JG
ConControl verter unit unit
1374
M061 M061
200L
52 100 400 52
1200
400 400
500
400
300
1200
700
52
1104
3804 4908
2204
203
800
Service area
View B-B
View C-C 600
VIEW A-A
1112
1700
317
187 87
570
600
ECMB -18-2
600 70
1405
87
1100
1200
800 100 137 187
1700
317
87 50
1800
250
80 2172 102
2000
102
Additional lenghts and weights Size 18 Lenght Weight Weight
Casing Kg/m EMCC excl. EMCA EMUA converter Al,6r – – – 400 0 157 112 – 76 –236 Small face area –272
EMUN cooler Al,8r Al,10r Cu,6r 0 0 0 – 188 – 140 – 92 – 235 –199 – 127
Cu,8r Cu,10r 0 0 0 89 – 94 – 127
= Choice in example
4600 GB 01.09
37 For more details visit www.marinemegastore.com or call 0871 8732404
37
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–470–090–1, left View A-A 114
205 465
75
DN50
50 974
50
Ø 1150
100 DN25 100
View C-C
52 7,5 kw GJ 031
200
670 50 1574 30
132M
10 kw GJ 034 160M
Converter Control unit unit
770 52
52
700
300
300
300 900
400
1404
400
600
900
52 100
3304 4708
1404
229
222
900
Service area
View C-C 696
500
187
800
417
87 ECMB -06-2
400
404 500
70 966
200
600
100
137 417
800
187
Motor limitation Max Motor EMCB IEC 06-2 132M 06-3 160M
L
W
W
250
1000
87 800 87
50
80
1200 1372
102
Weight standard example: Max demensions L W – 264 602 223
EMCA casing (L=3304) 449 EMCF filter (supply+exhaust) 33 EMCB/T size 2, 132M iron (exahust) 60+72= 132 EMCR rotor 126 EMCC cubicle+(cable, actuators, conv. L=1000) 106 EMCO exhaust air section 2 EMCB/T size3, 160M iron (supply) 95+115= 210 EMUA casing (L=1404) 105 EMUC emty section (L=300) 0 EMUN cooling sect. (Cu/Cu, 8r, max face) 206 EMUS zone air distrib. sect. (end wall/roof) 46 EMAZ–14 base frame (L=4700) 161 EMAA–06–470–090–1 Weight Kg 1576 4600 GB 01.09
38 For more details visit www.marinemegastore.com or call 0871 8732404
38
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–470–090–1, right View B-B
465 205
75
114
7,5 kw GJ 031 132M
200 50
Ø 1150
670 50 1574 30
View C-C
52 DN25 100 100
DN50
50 974
10 kw ConGJ 034 Control verter unit unit 160M
770 52 100 52
900
300 400
400
600
300
900
3304
700
300
52
1404 4708
1404
222
900
229
Service area
View C-C
500
VIEW A-A 417
696
800
187 87 400
ECMB -06-2
500 404
87
70 800
966
200
600
87 137
100 1200 1372
102 187
800
50
417
1000
250
80
Additional lenghts and weights Size 06 Lenght Weight Weight
Casing Kg/m EMCC excl. EMCA EMUA converter Al,6r – – – 400 0 107 75 – 55 – 93 Small face area –108
Al,8r 0 – 74 – 93
EMUN cooler Al,10r Cu,6r 0 0 – 54 – 36 – 78 – 66
Cu,8r Cu,10r 0 0 0 36 – 39 – 11
Al,1r 0 – 11
EMUE heater Al,2r Cu,1r 0 0 0 0
Cu,2r 0 21
= Choice in example
4600 GB 01.09
39 For more details visit www.marinemegastore.com or call 0871 8732404
39
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–500–090–1, left View A-A 149
75
205 465 52 50
11 kw
DN80
100 100
Ø 1580
DN50
View C-C
300
GJ 040 970 160M
50
30 2174 50
22 kw GJ 045
1274
160M
Converter Control unit unit
1070
160M
52 300 52
300
700
300 1100
300
400
500
400
100 1100
52
3604
1404 5008
1804
222
203 Service area
View B-B 894
800
600
1100
187
167
View A-A 517
View C-C ECMB -12-02
504
600
600
1320
70
137
1000
1000
800 100
137 517
1100
187
137 250
1400
80
50 1772 1600
102
Motor limitation Max Motor EMCB IEC 12-2 160L 12-3 180L
L
W
W
102
Weight standard example: Max demensions L W – 343 – 229
EMCA casing (L=3604) EMCF filter (supply+exhaust) EMCB/T size 2, 160L iron (exahust) 160+127= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=900) EMCO exhaust air section EMCB/T size 3, 180M iron (supply) 142+178= EMUA casing (L=1404) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMUE heating sect. (Cu/AL, 2r.) EMAZ–14 base frame (L=5000) EMAA–12–500–090–1 Weight Kg
686 43 233 204 119 3 320 135 0 360 46 186 2361
4600 GB 01.09
40 For more details visit www.marinemegastore.com or call 0871 8732404
40
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–500–090–1, right View B-B 465 205
75
149
52 50
11 kw
View C-C
160M
Ø 1580
GJ 040 970
300 DN50
DN80
100 100 50
2174 30 50
22 kw GJ 045
ConControl verter unit unit
1070
1274
M061
160M
52 300
300
100 52
1100
400
500
400
1100
300
700
300
52
1404
3604 5008
1804
222
203 Service area
800
View B-B
View C-C 600
600
VIEW A-A 517
894
1100
187
167
600
ECMB -12-02
504
70
137
1000
1320
1000
800 100
137
137 187
1100
517
50
1400
80
250
1772 1600
102
102
Additional lenghts and weights Size 12 Lenght Weight Weight
Casing Kg/m EMCC EMUN cooler excl. EMCA EMUA converter Al,6r Al,8r Al,10r Cu,6r – – – 400 0 0 0 0 143 97 – 56 – 173 – 137 – 103 – 68 Small face area – 204 – 177 – 151 – 127
Cu,8r Cu,10r 0 0 0 64 – 77 – 29
Al,1r 0 – 25
EMUE heater Al,2r Cu,1r 0 0 0 1
Cu,2r 0 39
= Choice in example
4600 GB 01.09
41 For more details visit www.marinemegastore.com or call 0871 8732404
41
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–520–090–1, left View B-B 205 465
100 DN50 100
DN80
52 22kw
300 50
GJ 045 Ø 1880
149 75
View C-C
View A-A
970 180M
50
30 2174 50
30kw GJ 050
1374
GJ 045
160M 160M
Converter Control unit unit
1070
200L
52 100 400 52
300
700
400 1200
300
400
500
1404
400
1200
52
3804 5208
2204
222
203
800
Service area
View B-B
View C-C
View A-A
600
1112
187
1700
317
87 ECMB -18-2
570
600
600 70
87
1405 1100
800 800
100
137 317
1700
187
250
1800
1200
87 80
50
2172 102
Motor limitation Max Motor EMCB IEC 18-2 180M 18-3 200M
L
W
W
2000
Weight standard example: Max demensions L W – 329 – 332
EMCA casing (L=3804) 806 EMCF filter (supply+exhaust) 57 EMCB/T size 2, 160L iron (exahust) 142+178= 320 EMCR rotor 204 EMCC cubicle+(cable, actuators, conv. L=900) 119 EMCO exhaust air section 4 EMCB/T size 3, 180L iron (supply) 170+250= 420 EMUA casing (L=1404) 156 EMUC emty section (L=300) 0 EMUN cooling sect. (Cu/Cu, 8r, max face) 483 EMUE heating sect. (Cu/Al, 2r.) 46 EMAZ–14 base frame (L=5200) 210 EMAA–18–520–090–1 Weight Kg 2871 4600 GB 01.09
42 For more details visit www.marinemegastore.com or call 0871 8732404
42
102
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–520–090–1, right View B-B
22kw 970 180M
300 50
Ø 1880
GJ 045
View C-C
465 205
52
75 149
DN80
DN50 100 100 50
2174 30 50
30kw GJ 050
ConControl verter unit unit
1070
1374
540 JG
M061 M061
200L
52 100 400
400 52
1200
400
500
400
1200
300
700
3804
300
52
1404 5208
2204
203
800
222
Service area
View B-B
View C-C 600
VIEW A-A
1112 317
1700
187 87
600
ECMB -18-2
570
600 70
87
1405 800 008
1100
137
1200
100 187
1700
87
317 50
1800
250
80 2172 2000
102
102
Additional lenghts and weights Size 12 Lenght Weight Weight
EMUN cooler Casing Kg/m EMCC excl. EMCA EMUA converter Al,6r Al,8r Al,10r Cu,6r – – – 400 0 0 0 0 157 112 – 76 – 236 – 188 – 140 – 92 Small face area – 272 – 235 – 199 – 127
Cu,8r Cu,10r 0 0 0 89 – 94 – 127
Al,1r 0 – 28
EMUE heater Al,2r Cu,1r 0 0 0 1
Cu,2r 0 54
= Choice in example
4600 GB 01.09
43 For more details visit www.marinemegastore.com or call 0871 8732404
43
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–520–094–1, left View A-A 205 465
DN25
DN50
100 100
52
10 kw GJ 034
974
160M
52
500
300
700
300
7,5 kw
200 Ø 1150
75
View C-C
392 114
GJ 031 670
132M
30 Converter Control unit unit
770 50 52
300 900
1904
400
600
1574
400
100
900
3304 5208
1404
229
222
900
Service area
View A-A View C-C
View B-B 696
500
202
404 500
600
100
W
44
W
250
1000
50
197 80 1372
Weight standard example:
Motor limitation
L
Ø160 2 x 290
137
Max Motor EMCB IEC 06-2 132M 06-3 160M
197
700
966
187
Ø200
250 70
800
452
197
ECMB -06-2
417
3 x 250
EMCA casing (L=3304) 449 EMCF filter (supply+exhaust) 33 EMCB/T size 2, 132M iron (exahust) 60+72= 132 EMCR rotor 126 EMCC cubicle+(cable, actuators, conv. L=1000) 106 EMCO exhaust air section 18 EMCB/T size 3, 160M iron (supply) 95+115= 210 EMUA casing (L=1904) 142 EMUC emty section (L=300) 0 EMUN cooling sect. (Cu/Cu, 8r, max face) 206 EMUE heating sect. (Cu/Al, 2r.) 46 EMUR distrib. sect. (end wall/roof) 63 EMAZ–14 base frame (L=5200) 171 EMAA–06–520–094–1 Weight Kg 1702 4600 GB 01.09 For more details visit www.marinemegastore.com or call 0871 8732404 44
Max demensions L W – 264 602 223
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–520–094–1, right View B-B
465 205 7,5 kw
670 132M
1574
200 Ø 1150
GJ 031
View C-C
52
30
114 392
75
DN25
DN50
100 100
10 kw ConGJ 034 Control verter unit unit 160M
770 50 52
300
100 900
400
600
400
900
974
300
700
300
500
52
1904
3304 5208
1404
229
222
900
Service area
View C-C 500
VIEW A-A
696
452
202 197
ECMB -06-2
500 404
3 x 250
Ø200
250
70 197 966
700
Ø160
600
2 x 290 100
137 187
800
197 50
417
1000
250
80 1372
Additional lenghts and weights Size 06 Lenght Weight Weight
Casing Kg/m EMCC excl. EMCA EMUA converter Al,6r – – – 400 0 107 75 – 55 – 93 Small face area –108
Al,8r 0 – 74 – 93
EMUN cooler Al,10r Cu,6r 0 0 – 54 – 36 – 78 – 66
Cu,8r Cu,10r 0 0 0 36 – 39 – 11
Al,1r 0 – 11
EMUE heater Al,2r Cu,1r 0 0 0 0
Cu,2r 0 21
EMUR air distributor c=0 bb=10 bb=11 – 200 – 200 0 – 32 –8 0 = Choice in example
4600 GB 01.09
45 For more details visit www.marinemegastore.com or call 0871 8732404
45
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–550–094–1, left View A-A 392 149
75
205 465 52 11 kw
DN80
100 100
GJ 040 Ø 1580
DN50
View C-C
300
970 160L
30 2174
22 kw GJ 045
1274
160M
Converter Control unit unit
1070 50
180M
52 300 52
500
300
700
300
300 1100
400
500
1904
100 1100
400
52
3604 5508
1804
203
222
Service area
View B-B 894
800
View C-C
View A-A
600 202
5x250
352
187 ECMB -12-2
ø200
504 600
2x250 70 202 1000
1320 800
3x290 100
137 250 517
1100
Max Motor IEC 160L 180M
L
W
W
1400
50
202
187
80 327
Weight standard example:
Motor limitation EMCB 12-2 12-3
ø160
Max demensions L W – 343 – 229
EMCA casing (L=3304) EMCF filter (supply+exhaust) EMCB/T size 2, 160L iron (exahust) 106+127= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=900) EMCO exhaust air section EMCB/T size 3, 180M iron (supply) 142+178= EMUA casing (L=1904) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMUE heating sect. (Cu/Al, 2r.) EMUR distrib. sect. (end wall/roof) EMAZ–14 base frame (L=5500) EMAA–12–550–094 Weight Kg
1772 4x250
686 43 233 204 119 38 320 184 0 360 72 102 197 2558
4600 GB 01.09
46 For more details visit www.marinemegastore.com or call 0871 8732404
46
477
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–550–094–1, right View B-B 465 205
75
149 392
52 11 kw
160L
View C-C
970
300 Ø 1580
GJ 040
2174 30
DN50
DN80
100 100
22 kw ConControl verter unit unit
1070 50
GJ 045
1274
M061
180M
52 300
100 52
1100
300 400
500
400
300
1100
3604
700
300
500
52
1904 5508
1804
203
222
Service area
800
View B-B
View C-C 600
VIEW A-A 352
894
5x250
202 187
ø200 2x250
ECMB -12-2
600 504
70
202 ø160
1000
1320
3x290
800 100
137 187
1100
517
202 50
1400
80
250
477
Additional lenghts and weights Size 12 Lenght Weight Weight
EMUN cooler Casing Kg/m EMCC excl. EMCA EMUA converter Al,6r Al,8r Al,10r Cu,6r – – – 400 0 0 0 0 143 97 – 56 – 173 – 137 – 103 – 68 Small face area –204 – 177 – 151 – 127
Cu,8r Cu,10r 0 0 0 64 – 77 – 29
Al,1r 0 – 25
EMUE heater Al,2r Cu,1r 0 0 0 1
Cu,2r 0 39
1772 4x250
327
EMUR air distributor c=0 bb=10 bb=11 – 200 – 200 0 – 50 – 10 0 = Choice in example
4600 GB 01.09
47 For more details visit www.marinemegastore.com or call 0871 8732404
47
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–570–094–1, left View A-A 392
149 75
205 465
52 22kw
100 100
GJ 045 180M
30 2174 50
30kw GJ 050 GJ 045
1374
160M 160M
2
970
Ø 1880
DN80
View C-C
300 DN50
Converter Control unit unit
3
1070
200L
100 400 52
500
300
700
300
400 1200
400
500
400
1200
52
50
3804
1904 5708
2204
222
203
800
Service area
View B-B
View A-A 600
1112
202
View C-C
6x250
502
187 ECMB -18-2
ø200
2x250
570 600 70
252 ø160 1100
1405
3x290
800 100
137 250 317
1700
Max Motor IEC 180L 200M
L
W
W
80
50
187
2172
Weight standard example:
Motor limitation EMCB 18-2 18-3
1800
252
Max demensions L W – 329 – 332
327
5x250
EMCA casing (L=3804) EMCF filter (supply+exhaust) EMCB/T size 2, 180M iron (exahust) 142+178= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=900) EMCO exhaust air section EMCB/T size3, 180L iron (supply) 170+250= EMUA casing (L=1904) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMUS heating sect. (Cu/AL, 2r.) EMUR distrib. sect. (end wall/roof) EMAZ–14 base frame (L=5700) EMAA–18–570–094–1 Weight Kg
806 57 320 204 119 43 420 212 0 483 92 141 224 3121
4600 GB 01.09
48 For more details visit www.marinemegastore.com or call 0871 8732404
48
627
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–570–094–1, right View B-B 465 205
52 22kw
View C-C
970 180M
392
300 Ø 1880
GJ 045
75 149
2174 30 50
DN50
DN80
100 100
30kw GJ 050
ConControl verter unit unit
1070
540 JG
1374
M061 M061
200L
100 400
400 52
1200
400
500
400
1200
300
300
700
3804
500
52
1904 5708
2204
203
800
222
Service area
View B-B
VIEW A-A 600
1112
502
6x250
202
View C-C
187 ø200
ECMB -18-2
600 570
2x250
70
252 ø160
1405
3x290
1100 800
252
100
137 187
1700
317
50
1800
250
80 2172 627
5x250
327
Additional lenghts and weights Size 18 Lenght Weight Weight
Casing Kg/m EMCC EMUN cooler excl. EMCA EMUA converter Al,6r Al,8r Al,10r Cu,6r – – – 400 0 0 0 0 157 112 – 76 – 236 – 188 – 140 – 92 Small face area – 272 – 235 – 199 – 127
Cu,8r Cu,10r 0 0 0 89 – 94 – 127
Al,1r 0 – 28
EMUE heater Al,2r Cu,1r 0 0 0 1
Cu,2r 0 54
EMUR air distributor c=0 bb=10 bb=11 – 200 – 200 0 – 72 – 24 0 = Choice in example
4600 GB 01.09
49 For more details visit www.marinemegastore.com or call 0871 8732404
49
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–490–095–1, left View A-A 205 465
100
7,5 kw GJ 031
200 Ø 1150
DN50
52
View C-C
392
132M
10 kw Converter 160M unit
GJ 034
974
Control unit
670 50 1574 30 770 52
300 52
500
700
300
400
900
1604
600
400
52 100
900
3304 4908
1404
222
900
Service area
View C-C
696
500
202
3 x 250
452
197 ECMB -06-2
404 500 70
197 Ø 160
700
966
2 x 290
600 100
137 417
800
187
Max Motor IEC 132M 160M
L
W
W
250
1000
197 80
50
1372
Weight standard example:
Motor limitation EMCB 06-2 06-3
Ø 200
250
Max demensions L W – 264 602 223
EMCA casing (L=3304) EMCF filter (supply+exhaust) EMCB/T size 2, 132M iron (exahust) 60+72= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=1000) EMCO exhaust air section EMCB/T size3, 160M iron (supply) 95+115= EMUA casing (L=1604) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMUR distrib. sect. (end wall/roof) EMAZ–14 base frame (L=4900) EMAA–06–490–095–1 Weight Kg
449 33 132 126 106 18 210 120 0 206 63 165 1628
4600 GB 01.09
50 For more details visit www.marinemegastore.com or call 0871 8732404
50
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–490–095–1, right
465 205 7,5 kw GJ 031 132M
200 Ø 1150
670 50 1574 30
View C-C
52
Control unit
770
392
DN50 100
10 kw ConGJ 034 verter unit 160M
974
52 300
100 52
900
400
600
400
900
300
700
3304
500
52
1604 4908
1404
222
900
Service area
VIEW A-A 500
696 452
Ø 200
250
70 966
197 Ø 160
700
600 137
2 x 290
100 187
202 197
ECMB -06-2
500 404
3 x 250
800
417
197 50
1000
250
80 1372
Additional lenghts and weights Size 06 Lenght Weight Weight
Casing Kg/m EMCC excl. EMCA EMUA converter Al,6r – – – 400 0 107 75 – 55 – 93 Small face area – 108
Al,8r 0 – 74 – 93
EMUN cooler Al,10r Cu,6r 0 0 – 54 – 36 – 78 – 66
EMUR air distributor Cu,8r Cu,10r c=0 bb=10 bb=11 0 0 – 200 – 200 0 0 36 – 32 –8 0 – 39 – 11 = Choice in example
4600 GB 01.09
51 For more details visit www.marinemegastore.com or call 0871 8732404
51
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–520–095–1, left View A-A 392
205 465 52 11 kw
DN80 100
GJ 040
Ø 1580
View C-C
300
50
Converter Control unit unit
160M
2174
30
22 kw
GJ 045
1274
970 160M
1070
160M
52 300
300 52
500
700
300
1100
400 500 3604
1604
400
100 1100
52
5208
1804
203 Service area
View B-B 894
800
202
600
View C-C
5x250
View A-A 352
167 ø200
ECMB -12-2
2x250
504 600 70
202 ø160
1000
1320 800
100
137 1100
517
187
250
1400
3x290
202 80
50 1772 102
L
W
W
477
Weight standard example:
Motor limitation Max Motor EMCB IEC 12-2 160M 12-3 180M
4x250
Max demensions L W – 343 – 229
EMCA casing (L=3604) EMCF filter (supply+exhaust) EMCB/T size 2, 160L iron (exahust) 106+127= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=900) EMCO exhaust air section EMCB/T size 3, 180M iron (supply) 142+320= EMUA casing (L=1604) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMUR distrib. sect. (end wall/roof) EMAZ–14 base frame (L=5200) EMAA–12–520–095–1 Weight Kg
686 43 233 204 119 38 311 155 0 360 102 190 2441
4600 GB 01.09
52 For more details visit www.marinemegastore.com or call 0871 8732404
52
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–520–095–1, right View B-B 465 205
392
52 11 kw Ø 1580
970 160M
50 2174
View C-C
300
GJ 040
30
22 kw ConControl verter unit unit
1070
DN80 100
GJ 045
1274
M061
160M
52 300
100 52
1100
300 400
500 400 3604
1100
300
700
500
52
1604 5208
1804
203 Service area
800
View B-B
VIEW A-A 600
352
894
5x250
202
View C-C
167 ø200 2x250
ECMB -12-2
600 504
70
202 ø160
1000
1320
3x290
800 100
137 187
1100
517
202 50
1400
250
80 1772 477
4x250
102
Additional lenghts and weights Size 12 Lenght Weight Weight
Casing Kg/m EMCC EMUN cooler excl. EMCA EMUA converter Al,6r Al,8r Al,10r Cu,6r – – – 400 0 0 0 0 143 97 – 56 – 173 – 137 – 103 – 68 Small face area – 204 – 177 – 151 – 127
EMUR air distributor Cu,8r Cu,10r c=0 bb=10 bb=11 0 0 – 200 – 200 0 0 64 – 50 – 10 0 – 77 – 29 = Choice in example
4600 GB 01.09
53 For more details visit www.marinemegastore.com or call 0871 8732404
53
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–540–095–1, left View A-A 392
205 465 52 22kw
View C-C
300
100
GJ 045 Ø 1880
DN80
GJ 045 160M 160M
2174
30 50
30kw
GJ 050 1374
970 180M
Converter Control unit unit
1070
200L
52 100 400 52
500
700
400
300
1200
400
500
400
1200
52
3804
1604 5408
2204
203
800
Service area
View B-B
View A-A
View C-C 600
1112
202
6x250
502
187 ø200
ECMB -18-2
2x250
570 600
70
252 ø160 3x290
1100 1405 800
252
100
137
0 317
1700
187
250
1800
80
50
2172 327
Weight standard example:
Motor limitation Max Motor EMCB IEC 18-2 180M 18-3 200M
L
W
W
5x250
Max demensions L W – 329 – 332
EMCA casing (L=3804) EMCF filter (supply+exhaust) EMCB/T size 2, 180M iron (exahust) 142+178= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=900) EMCO exhaust air section EMCB/T size 3, 180L iron (supply) 170+250= EMUA casing (L=1604) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMUR distrib. sect. (end wall/roof) EMAZ–14 base frame (L=5400) EMAA–12–520–095–1 Weight Kg
806 57 320 204 119 43 420 179 0 483 141 241 2986
4600 GB 01.09
54 For more details visit www.marinemegastore.com or call 0871 8732404
54
627
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–540–095–1, right View B-B 465 205
392
52 22kw
View C-C
970 180M
2174
300 Ø 1880
GJ 045
30 50
30kw ConControl verter unit unit
1070
DN80 100
GJ 050 1374
540 JG M061 M061
200L
52 100 400
400 52
1200
400
500
400
1200
300
3804
700
52
500
1604 5408
2204
203
800
Service area
View B-B
View C-C 600
VIEW A-A
1112 502
6x250
202 187
ø200
ECMB -18-2
600 570
2x250 70
252 ø160
1100
3x290
1405 800
252
100
137 187
1700
317
50
1800
250
80 2172 627
5x250
327
Additional lenghts and weights Size 18 Lenght Weight Weight
Casing Kg/m EMCC EMUN cooler excl. EMCA EMUA converter Al,6r Al,8r Al,10r Cu,6r – – – 400 0 0 0 0 157 122 – 76 – 236 – 188 – 140 – 92 Small face area – 272 – 235 – 199 – 127
EMUR air distributor Cu,8r Cu,10r c=0 bb=10 bb=11 0 0 – 200 – 200 0 0 89 – 72 – 24 0 – 94 – 127 = Choice in example
4600 GB 01.09
55 For more details visit www.marinemegastore.com or call 0871 8732404
55
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–510–096–1, left View A-A 592 300 115
100
7,5 kw
200 Ø 1150
DN50
52
View C-C
DN32
205 465 GJ 031
670 50 1574 30
132M
10 kw GJ 034 974 160M
Converter Control unit unit
770 52
300 52
700
700
300
900
1804
400
600
400
52 100
900
3304 5108
1404
222
226
900
Service area
View B-B
View C-C
696
View A-A
500
202
3 x 250
452
197 ECMB -06-2
404 500 70
187
L
W
W
Ø160
250
1000
197 80
50
1372
Weight standard example:
Motor limitation Max Motor EMCB IEC 06-2 132M 06-3 160M
197 250 330
100
137 800
Ø200
700
966 600
417
250
Max demensions L W – 264 602 223
EMCA casing (L=3304) EMCF filter (supply+exhaust) EMCB/T size 2, 132M iron (exahust) 60+72= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=1000) EMCO exhaust air section EMCB/T size 3, 160M iron (supply) 95+115= EMUA casing (L=1804) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMUD distrib. sect. (Cu/Al, end wall/roof) EMAZ–14 base frame (L=5100) EMAA–06–510–096–1 Weight Kg
449 33 132 126 106 18 210 135 0 206 111 169 1695
4600 GB 01.09
56 For more details visit www.marinemegastore.com or call 0871 8732404
56
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–510–096–1, right View B-B 465 205
52 7,5 kw 132M
200 Ø 1150
GJ 031 670 50 1574 30
View C-C
115
592 300 DN32
DN50
100
10 kw GJ 034 ConControl verter unit unit 160M
770
974
52 300
100 52
900
400
600
400
900
300
700
3304
700
52
1804 5108
1404
222
900
226
Service area
VIEW A-A 500
696
452
3 x 250
202 197
500
ECMB -06-2
404
Ø200
250
Ø160
197 250
70 700
966 600
330 100
137 187
800
197 50
417
1000
80
250
1372
Additional lenghts and weights Size 06 Lenght Weight Weight
Casing Kg/m EMCC excl. EMCA EMUA converter Al,6r – – – 400 0 107 75 – 55 – 93 Small face area – 108
Al,8r 0 – 74 – 93
EMUN cooler Al,10r Cu,6r 0 0 – 54 – 36 – 78 – 66
Cu,8r Cu,10r c=1 0 0 – 200 0 36 – 14 – 39 – 11 3
EMUD air distributor c=2 c=3 c=4 c=5 0 300 – 200 – 200 0 18 – 64 – 64 (Al, 4r) 17 35 – 47 – 47 (Cu, 4r) = Choice in example
4600 GB 01.09
57 For more details visit www.marinemegastore.com or call 0871 8732404
57
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–540–096–1, left View A-A
592 300 115
205 465 52 11 kw
DN80
100
Ø 1580
DN32
View C-C
300
GJ 040 970 160M
30 2174
22 kw GJ 045
1274
160M
50
Converter Control unit unit
1070
160M
52 300
300 52
700
700
300
1100
400
1804
500
400
1100
52
100
3604 5408
1804
226
203 Service area
800
View A-A
View C-C
View B-B 894
202
600
5x250
352
187 ø200 ECMB -12-2
504
2x250
600 70
212 ø160
2x250 1320
1000
800
350 137 517
1100
187
100 250
1400
212 80
50 327
Weight standard example:
Motor limitation Max Motor EMCB IEC 12-2 160L 12-3 180M
L
W
W
1772 4x250
Max demensions L W – 343 – 229
EMCA casing (L=3604) EMCF filter (supply+exhaust) EMCB/T size 2, 160L iron (exahust) 106+127= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=1000) EMCO exhaust air section EMCB/T size 3, 180M iron (supply) 142+178= EMUA casing (L=1804) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMUD distrib. sect. (Cu/Al, end wall/roof) EMAZ–14 base frame (L=5400) EMAA–12–540–096–1 Weight Kg
686 43 233 204 119 38 320 174 0 360 175 194 2546
4600 GB 01.09
58 For more details visit www.marinemegastore.com or call 0871 8732404
58
477
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–540–096–1, right View B-B 465 205
592 115 300
52 11 kw
160M
View C-C
970
300 Ø 1580
GJ 040
2174 30
DN80
DN32 100
22 kw
50
GJ 045
ConControl verter unit unit
1070
1274
M061
160M
52 300 100
52
1100
300 400
500
400
1100
300
700
700
52
1804
3604 5408
1804
203
226
Service area
800
View B-B
VIEW A-A
View C-C 600
352
894
5x250
202 187
ø200 600
2x250
ECMB -12-2
504
70
212 ø160
1320
2x250
1000 800 350 100
137 187
1100
517
212 50
1400
250
80 477
1772 4x250
327
Additional lenghts and weights Size 12 Lenght Weight Weight
Casing Kg/m EMCC EMUN cooler excl. EMCA EMUA converter Al,6r Al,8r Al,10r Cu,6r – – – 400 0 0 0 0 143 97 – 56 – 173 – 137 – 103 – 68 Small face area – 204 – 177 – 151 – 127
Cu,8r Cu,10r c=1 0 0 – 200 – 19 0 64 – 77 – 29 8
EMUD air distributor c=2 c=3 c=4 c=5 0 300 – 200 – 100 0 22 – 104 – 95 (Al, 4r) 27 49 – 77 – 68 (Cu, 4r) = Choice in example
4600 GB 01.09
59 For more details visit www.marinemegastore.com or call 0871 8732404
59
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–560–096–1, left View A-A
592
205 465 52
300 115 22kw
View C-C
300
100
GJ 045 Ø 1880
DN80
DN32
GJ 050
1374
2 970
180M
30 2174
30kw
GJ 045 160M 160M
200L
2
50 1070
Con- Control verter unit unit
52 100 400
400 52
700
700
300
1200
400
500
400
52
1200
3804
1804 5608
2204
203
226
800
Service area
View B-B
View A-A 600
1112
202
View C-C
6x250
502
187 ø200
ECMB -18-2
570
2x250
600 70
1
212 ø160 2x250 1405
1100
800 800
400 100
317
1700
187
137
250
1800
262 80
50
2172 327
Weight standard example:
Motor limitation Max Motor EMCB IEC 18-2 180M 18-3 200M
L
W
W
5x250
Max demensions L W – 329 – 332
EMCA casing (L=3804) EMCF filter (supply+exhaust) EMCB/T size 2, 180M iron (exhaust) 142+178= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=900) EMCO exhaust air section EMCB/T size 3, 180L iron (supply) 170+250= EMUA casing (L=1804) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMUD distrib. sect. (Cu/Al, end wall/roof) EMAZ–14 base frame (L=5600) EMAA–18–560–096–1 Weight Kg
806 57 320 204 119 43 420 201 0 483 224 224 3101
4600 GB 01.09
60 For more details visit www.marinemegastore.com or call 0871 8732404
60
627
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–560–096–1, right View B-B 465 205
592
52
115 300 22kw Ø 1880
GJ 045
View C-C
300
970 180M
2174 30
30kw
50 1070
Control Conunit verter unit
DN80
DN32 100
GJ 050
1374
540 JG M061 M061
200L
52 100 400
400 52
1200
400
500
400
1200
300
3804
700
700
52
1804 5608
2204
203
800
226
Service area
View A-A
View B-B 600
1112 502
6x250
202
View C-C 600
187 ø200
ECMB -18-2
570
2x250 70 212 ø160 2x250
1405
1100 0800 08
400 100
137
187
1700
317
262 50
1800
250
80 2172 627
5x250
327
Additional lenghts and weights Size 18 Lenght Weight Weight
Casing Kg/m EMCC EMUN cooler excl. EMCA EMUA converter Al,6r Al,8r Al,10r Cu,6r – – – 400 0 0 0 0 157 112 – 76 – 236 – 188 – 140 – 92 Small face area – 272 – 235 – 199 – 127
Cu,8r Cu,10r c=1 0 0 – 200 0 89 – 22 – 94 – 127 19
EMUD air distributor c=2 c=3 c=4 c=5 0 300 – 200 0 0 29 – 132 – 110 (Al, 4r) 41 70 – 93 – 69 (Cu, 4r) = Choice in example
4600 GB 01.09
61 For more details visit www.marinemegastore.com or call 0871 8732404
61
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–510–097–1, left View A-A 205 465 592 332 120 29 29 DN 25 DN 50
52
Ø 1150
View C-C
100
7,5 kw
200
GJ 031
132M
10 kw
30
Con- Control GJ 034 verter unit 160M unit
974
670 50 1574
770 52
52
700
700
300
300
900
400
1804
600
400
52 100
900
3304 5108
1404 118 222
111
900
Service area
View B-B
View A-A
View C-C
696
202
500
3 x 250
452
197
ECMB -06-2
Ø 200
250
404 500 70
197 700
966 600
Ø 160 2 x 290 197
137 100
417
800
187
250
1000
80
50
1372
Motor limitation EMCB 06-2 06-3
Max Motor IEC 132M 160M
Max demensions L W – 264 602 223
L
W
W
4600 GB 01.09
62 For more details visit www.marinemegastore.com or call 0871 8732404
62
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–06–510–097–1, right View B-B 465 205
52
1574
7,5 kw
200
View C-C
GJ 031
Ø 1150
670 50
132M
592 120 332 DN 25 29 29 DN 50 100
10 kw Control ConGJ 034 verter unit unit 160M
30
770
974
52 100 52
900
400
600
400
900
300
300
700
3304
700
52
1804 5108
1404 118 222
900
111
Service area
View B-B
View C-C 500
View A-A
696
452
3 x 250
202 197
500
ECMB -06-2
404
Ø 200
250
70 197 Ø 160
966
700
600
2 x 290 197
137 100 187
800
417
Additional lenghts and weights Size 06 Lenght Weight Weight
Casing Kg/m EMCC excl. EMCA EMUA converter Al,6r – – – 400 0 107 75 – 55 – 93 Small face area –108
Al,8r 0 – 74 – 93
50
1000
250
80 1372
EMUS zone air distributor EMUN cooler d=1 Al,10r Cu,6r Cu,8r Cu,10r C=1 C=2 C=3 C=4 C=5 0 0 0 0 – 300 – 200 – – 300 – – 54 – 36 0 36 – 36 – 10 – – 27 – – 78 – 66 – 39 – 11 d=2 = Choice in example C=1 C=2 C=3 C=4 C=5 – 100 0 – – 100 – – 26 0 – – 17 – d=3 C=1 C=2 C=3 C=4 C=5 200 300 – 200 – – 16 10 – –7 –
4600 GB 01.09
63 For more details visit www.marinemegastore.com or call 0871 8732404
63
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–540–097–1, left View A-A 592 332 120
52
29
300
100
Ø 1580
DN80
DN25
11 kw
View C-C
29
205 465
GJ 040 970 160M
30 2174 50
22 kw GJ 045 1274 160M
160M
Con- Control verter unit unit
1070 52
300 52
700
700
300
300 1100
400
500
400
1100
100
52
3604
1804 5408
1804
118 203 111 Service area
View B-B
800
View C-C
894
View A-A 202
600
5x250
352
187 ø200 ECMB -12-2
504
2x250
600 70
202 ø160
1320
1000
800 100
137 1100
517
187
250
1400
3x290
202 80
50 327
1772 4x250
Motor limitation Max Motor EMCB IEC 12-2 160L 12-3 180M
L
W
W
Max demensions L W – 343 – 229
EMCA casing (L=3604) 686 EMCF filter (supply+exhaust) 43 EMCB/T size 2, 160L iron (exahust) 106+127= 223 EMCR rotor 204 EMCC cubicle+(cable, actuators, conv. L=900) 119 EMCO exhaust air section 38 EMCB/T size 3, 180M iron (supply) 142+178= 320 EMUA casing (L=1804) 174 EMUC emty section (L=300) 0 EMUN cooling sect. (Cu/Cu, 8r, max face) 360 EMUS zone air distrib. sect. (end wall/roof) 165 EMAZ–14 base frame (L=5400) 194 EMAA–12–540–097–1 Weight Kg 2391 4600 GB 01.09
64 For more details visit www.marinemegastore.com or call 0871 8732404
64
477
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–12–540–097–1, right View B-B 465 205
592 120 332
52 11 kw
View C-C
160M
Ø 1580
GJ 040 970
29
300
2174 30 50
29
DN80
DN25 100
22 kw GJ 045 1274
Control Conunit verter M061 unit 160M
1070 52 300 100
52
1100
300 400
500
400
1100
300
3604
700
700
52
1804 5408
1804
118 203 111 Service area
800
View B-B
View C-C 600
View A-A 352
894
5x250
202 187
ø200 600
ECMB -12-2
504
2x250
70
202 ø160
1320
1000
3x290
800 100
137 187
1100
517
202 50
1400
250
80 477
1772 4x250
327
Additional lenghts and weights Size 12 Lenght Weight Weight
EMUS zone air distributor EMUN cooler d=1 Casing Kg/m EMCC excl. EMCA EMUA converter Al,6r Al,8r Al,10r Cu,6r Cu,8r Cu,10r C=1 C=2 C=3 C=4 C=5 – – – 400 0 0 0 0 0 0 – 300 – 200 – 100 – 300 – 300 143 97 – 56 – 173 – 137 – 103 – 68 0 64 – 40 – 12 22 – 28 – 17 Small face area –204 – 177 – 151 – 127 – 77 – 29 d=2 C=2 C=3 C=4 C=5 = Choice in example C=1 – 100 0 100 – 100 – 100 – 29 0 34 – 16 –5 d=3 C=1 C=2 C=3 C=4 C=5 200 300 400 200 200 – 16 13 46 –4 8
4600 GB 01.09
65 For more details visit www.marinemegastore.com or call 0871 8732404
65
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–560–097–1, left View A-A 205 465
592 332 120 29 29
300
100
GJ 045 Ø 1880
DN80
View C-C
DN25
52 22kw
30 2174 50 1070
30kw
GJ 050
1374
970 180M
GJ 045
160M 160M
200L
Con- Control verter unit unit
52 100 400 52
700
700
300
400 1200
400
500
400
1200
52
3804
1804
5608
2204
118 203 111 800
Service area
View B-B 1112
View C-C
View A-A
600 202
6x250
502
187 ø200
ECMB -18-2
2x250
570 600 70
252 ø160
1100
1405
3x290
800 100
137 317
1700
187
250
1800
252 80
50
2172 327
Max Motor EMCB IEC 18-2 180M 18-3 200M
Max demensions L W – 329 – 332
5x250
casing (L=3804) EMCA EMCF filter (supply+exhaust) EMCB/T size 2, 180M iron (exahust) 142+178= EMCR rotor EMCC cubicle+(cable, actuators, conv. L=900) EMCO exhaust air section EMCB/T size 3, 180L iron (supply) 170+250= EMUA casing (L=1804) EMUC emty section (L=300) EMUN cooling sect. (Cu/Cu, 8r, max face) EMUS zone air distrib. sect. (end wall/roof) EMAZ–14 base frame (L=5600) EMAA–18–560–097–1 Weight Kg
806 57 320 204 119 43 420 201 0 483 206 218 3077
4600 GB 01.09
66 For more details visit www.marinemegastore.com or call 0871 8732404
66
627
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
EMAA–18–560–097–1, right 465 205 52 22kw
View C-C
300 Ø 1880
GJ 045 970 180M
2174 30 50 1070
30kw Control Conunit verter unit
View B-B
592 120 332 29 29 DN80
DN25 100
GJ 050
1374
540 JG
M061 M061
200L
52 100 400 52
1200
400 400
500
400
1200
300
3804
700
700
52
1804
5608
2204
118 203 111 800
Service area
View B-B
View A-A
View C-C 600
1112 502
6x250
202 187
600
ø200
ECMB -18-2
570
2x250 70
252 ø160 3x290
1100
1405 800
252
100
137 187
1700
317
50
1800
250
80 2172 627
Additional lenghts and weights Size 06 Lenght Weight Weight
EMUN cooler Casing Kg/m EMCC excl. EMCA EMUA converter Al,6r Al,8r Al,10r Cu,6r Cu,8r Cu,10r C=1 – – – 400 0 0 0 0 0 0 – 300 157 112 – 76 – 236 – 188 – 140 – 92 0 89 – 49 Small face area –272 – 235 – 199 – 127 – 94 – 127 = Choice in example C=1 – 100 – 35 C=1 200 – 20
5x250
327
EMUS zone air distributor d=1 C=2 C=3 C=4 C=5 – 200 – 100 – 300 – 300 – 14 28 – 34 – 20 d=2 C=2 C=3 C=4 C=5 0 100 – 100 – 100 0 42 – 20 –6 d=3 C=2 C=3 C=4 C=5 300 400 200 200 15 57 –5 9
4600 GB 01.09
67 For more details visit www.marinemegastore.com or call 0871 8732404
67
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Codification Air handling unit assembly
EMAA-aa-bbb-ccc-d
Filter section
EMCF-aa-bb-c-d-e
Unit size (aa) 06, 12, 18
Unit size (aa) 06, 12, 18
Length, cm (bbb) 300 - 780 (with step of 10cm) Unit type (ccc) Public: 089, 090 Cabin: 094, 095, 096, 097
Filter class (bb) 03= short,class G3 (EU3), syntetic 05= short, class F5 (EU5), syntetic 15= long, class F5 (EU5), syntetic 16= long, class F6 (EU6), syntetic 17= long, class F7 (EU7), syntetic
Automation and control (d) 0= without 1= with
Position (c) 1= supply air 2= exhaust air
Air handling compact unit, casing
Material filter frame (d) 1= galvanized steel 2= stainless steel
EMCA-aa-bbb-c-d
Unit size (aa) 06, 12, 18
Inspection side (e) (Seen in supply/exhaust air direction)
Length, cm (bbb) 230 - 450 (with step of 10cm)
1= right hand 2= left hand
Casing insulation (c) 1= mineral wool, density 50 kg/m3 Material (d) 1= galvanized steel sheet, 0,7 mm 5= stainless steel sheet, 0,7 mm 2333 (AISI 304) 7= stainless steel sheet, 0,7 mm 2343 (AISI 316) Frame: stainless steel sheet 2333 (AISI 304)
Energy recovery section, REGOTERM (Hole rotor, hygr.+corr.prot. edges)
EMCR-aa-b-c-d-e
Unit size (aa) 06, 12, 18 Power supply motor (b) 1= 3x230/400 V, 50Hz 6= 3x255/440 V, 60Hz 8= 3x400/690 V, 50Hz
Motor classification (c) 0= no classification 3= Lloyd‘s register of shipping 4= Det Norske Veritas
Material (d) 1= galvanized steel 2= stainless steel Inspection side (e) (Seen in supply air direction) 1= right hand 2= left hand
4600 GB 01.09
68
For more details visit www.marinemegastore.com or call 0871 8732404
68
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Codification Cubicle section
EMCC-aa-bb-c-d-e
Fan section, B-wheel EMCB-aa-b-c-d-e-f-g (inkl.air distributor for supply air fan)
Unit size (aa) 06, 12, 18
Unit size (aa) 06, 12, 18
Length (bb) 05= cubicle section l=500 mm (aa=12,18) 06= cubicle section l=600 mm 09= cubicle and converter section l=900 mm (aa=12,18) 10= cubicle and converter section l=1000 mm
Fan size (b)
Material (c) 1= galvanized steel (when casing material EMCA d=1) 2= stainless steel (when casing material EMCA d=5,7) Main power connection (d) 1= top 2= bottom
2 3
aa 061218-
Fan size 2 GJ 031 GJ 040 GJ 045
Fan size 3 GJ 034 GJ 045 GJ 050
Version (c) 3= normal, belt driven CENTRIMASTER 4= heavy duty, belt driven CENTRIMASTER (Not when aa-b=06-2) Equipment (d) 0= without 1= with inlet guide vanes (c=3,4) 5= air-flow meter, Q-nozzle (c=3,4)
1= right hand 2= left hand
Material (e) 1= galvanized steel sheet 4= stainless steel, side withdrawable fan-wheel (fan house and impeller epoxy painted) 5= stainless steel (fan house and impeller epoxy painted)
Exhaust air connection
Position (f) 1= supply air (b=2,3) 2= exhaust air (b=2)
Inspection side (e) (Seen in supply air direction)
EMCO-aa-b-c-d
Inspection side (g) (Seen in supply/exhaust air direction)
Unit size (aa) 06, 12, 18 Exhaust air connections (b) 2= MINIDUCT Ă˜ 200, end wall 3= rectangular duct, end wall (c=0)
1= right hand 2= left hand
Non-return smoke dampers (c) 0= without smoke dampers 1= with smoke dampers (b=2) Inspection side (d) (Seen in exhaust air direction) 1= right hand 2= left hand
4600 GB 01.09
69
For more details visit www.marinemegastore.com or call 0871 8732404
69
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Codification Belt drive for EMCB fan
EMCT-aa-b-c-d-eeee-f
Empty section
Unit size (aa) 06, 12, 18
Unit size (aa) 06, 12, 18
Fan size (b) 2 3
Length, mm (b) 1= 100, not for single block 2= 200 6= 600 3= 300 7= 700 4= 400 8= 800 5= 500 9= 900
Version (c) 1= normal 2= heavy duty 3= normal, with one extra belt 4= heavy-duty, with one extra belt 5= normal, minimum two belts 6= heavy-duty, minimum two belts Position (d) 1= supply air (b=2,3) 2= exhaust air (b=2) 3= supply air (b=2,3)incl.extra set of belt 4= exhaust air (b=2)incl.extra set of belt
EMUC-aa-b-c-d-e
Duct connection (c) 0= without Inspection door (d) 0= without inspection door 3= with inspection door, possitive pressure (b=5-9) Inspection side (e) 1= right hand 2= left hand
Fan speed r/min (eeee) Speed control (f) 1= constant speed motor 2= frequency regulated motor
Air heater, hot water
EMUE-aa-b-c-d-e
Unit size (aa) 06, 12, 18 Air handling supply unit, casing
EMUA-aa-bbb-c-d-e-f-g
Unit size (aa) 06, 12, 18
Capacity variant (b) (Coil connection through roof ) 1=1 row, 2 mm fin part 2=2 row, 2 mm fin part
Length, cm (bbb) 030 - 330 (in step of 10 cm) Casing insulation (c) 1= mineral wool, density 50 kg/m3. Panel Material (d) 1= galvanized steel sheet, 0,7 mm 5= stainless steel sheet, 0,7 mm 2333 (AISI 304) 7= stainless steel sheet, 0,7 mm 2343 (AISI 316) Frame: stainless steel sheet 2333 (AISI 304)
Material (c) 1= Cu/Al 2= Cu/Cu Coil casing material (d) 1= galvanized steel 2= stainless steel Inspection side (e) 1= right hand 2= left hand
Version (e) 1= horizontal installation Air tightness class (f) 1= CEN A Casing form (g) 0= single block 4600 GB 01.09
70
For more details visit www.marinemegastore.com or call 0871 8732404
70
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Codification Steam/spray humidifyer
EMUQ-aa-b-c-d
Unit size (aa) 06, 12, 18
Air distributor system REGOVENT
EMUR-aa-bb-c-d
Unit size (aa) 06, 12, 18 Connection type (bb)
Type (b) 1= 1 spray pipe connection (c=0) 2= 2 spray pipe connection (c=0) 4= 4 spray pipe connection (c=0) 5= steem lances (c=1-9) Orifice plate hole diameter (c) 0= without 1= 2,25 4= 3,8 2= 2,75 5= 4,5 3= 3,3 6= 5,4
without with MINIDUCT Ø 160
Endwall b 0 1
Roof b 0 1
Non-return smoke dampers (c) 0= without 1= with 7= 6,5 8= 7,6 9= 8,7
Position (d) 1= right-hand side (b=1,5) 2= left-hand side (b=1,5) 3= allocated on right side and top (b=2,4) 4= allocated on left side and top (b=2,4)
Inspection side (d) 1= right hand 2= left han Air distributor system DUOVENT
EMUD-aa-b-c-d-e-f
Unit size (aa) 06, 12, 18 Heating medium, material (b) (Coil connection through roof)
Air cooler, cool water
EMUN-aa-bb-c-d-e-f-g
Unit size (aa) 06, 12, 18 Capacity variant (bb) (Coil connection through roof ) 06, 08, 10 Material (c) 1= Cu/Al 2= Cu/Cu Droplet eliminator (d) 0= without 1= with Coil version (e) 1= small face area 2= large face area
Coil position (f) 2= downstreem of the fan
1= water, Cu/Al 4 tube rows 3= water, Cu/Cu 4 tube rows Installation variant (c) 1= MINIDUCT Ø 160, end wall 2= MINIDUCT Ø 160, end wall, roof 3= MINIDUCT Ø 160, end wall, roof, extra large 4= rectangular ducts, end wall 5= rectangular ducts, end wall and roof Connection type (d) 0= without smoke gas damper or frame 1= with, smoke gas dampers (c=1,2,3) 2= with connection frame PG (c=4,5) 3= with connection frame Flange (c=4,5) Material (e) 1= galvanized steel 2= stainless steel Inspection side (f) 1= right hand 2= left hand
Inspection side (g) 1= right hand 2= left hand
4600 GB 01.09
71
For more details visit www.marinemegastore.com or call 0871 8732404
71
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Codification Air distributor - Cabin zone system
EMUS-aa-b-c-d-e-f-g
End wall outlet
Unit Size(aa) 06, 12, 18
Unit size (aa) 06, 12, 18
Heating medium, material (b) 1= hot water, Cu/Al 2= hot water Cu/Cu
Variant (b) 0= without opening 1= with rectangular opening
Zone variant (c) 1= 1 zone 2= 2 zones 3= 3 zones 4= one coil, dubble zone 5= one coil, tripple zone
Connection type (c) 0
c=1
c=2
c=4
c=5 (aa=12,18)
EMUV-aa-b-c-d-e
Material (d) 1= galvanized steel sheet, 0,7 mm 5= stainless steel sheet, 0,7 mm 2333 (AISI 304) 7= stainless steel sheet, 0,7 mm 2343 (AISI 316)
c=3 (aa=12,18)
Inspection side (e) 1= right hand 2= left hand
Connection type (d) 1= MINIDUCT Ø 160, end wall 2= MINIDUCT Ø 160, end wall, roof 3= MINIDUCT Ø 160, end wall, roof extra large Non-return smoke dampers (e) 0= without 1= with Material (f) 1= galvanized steel 2= stainless steel Inspection side (g) 1= right hand 2= left hand
4600 GB 01.09
72
For more details visit www.marinemegastore.com or call 0871 8732404
72
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Codification ACCESSORIES
Earthing cable (flexible duct connection)
Inspection window
EUAZ-23
EUAZ-01-b
Type (b) 1= one-glass 3= two-glass
Flexible connection (casing frame) Connection piece (casing frame) Counterflange (casing frame) d=2,4
EMAZ-25-bb-c-d EMAZ-26-bb-c-d EMAZ-27-bb-c-d
Unit size (bb) 06, 12, 18 Lifting tube, set
EMAZ-06-bb Position (c) 2= supply air outlet
Unit size (bb) 06, 12, 18
Bulkhead light
EMAZ-09-bb-c
Connection (d) 1= PG-joint, galvanized steel (not for EMAZ-27) 2= flange connection, galvanized steel 3= PG-joint, stainless steel (not for EMAZ-27) 4= flange connection, stainless steel
Unit size (bb) 06, 12, 18 Type (c) 2= without cable and switch
Damper (for casing frame)
EMAZ-28-bb-c-d
Unit size (bb) 06, 12, 18 Door lock, for one door
AHU packaging Unit size (bb) 06, 12, 18 Unit length, cm (ccc) 300 -780 (in step of 10cm) Transport type (d) 1= truck transport 2= container transport
EUAZ-14
EMAZ-22-bb-ccc-d
Damper type (c) 1= with damper CEN 3, galvanized steel 2= with damper CEN 4, galvanized steel 3= with damper CEN 3, stainless steel 4= with damper CEN 4, stainless steel Connection (d) 1= PG-joint 2= flange
Thermometer
EUAZ-35-bbbb-c
Type (bbbb) 5021 = -200C -> +600C 5022 = -200C -> +600C/-40F -> +1400F 5023 = 00C -> +1000C Delivery form (c) 0= separate delivered 1= mounted in function
4600 GB 01.09
73
For more details visit www.marinemegastore.com or call 0871 8732404
73
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Codification Coil connection flange EUAZ-40-b-c-d For one pipe connection (fitted and soldered) Pipe size no. (b) 0= 15 1= 25 2= 32 4= 50 5= 80 6= 100 Flange type (c) 4= flange soldered, without counterflange (b=1-5; d=2,4) [coil/bronze] 5= flange soldered, with counterflange, thread (b=1-5; d=1,3) [coil/bronze - piping/steel] 6= flange soldered, with counterflange, welding (b=1-5; d=1,3) [coil/bronze - piping/steel] Material (d) 1= steel 2= bronze 3= steel 4= bronze
(PN16 DIN 2633) (PN16 DIN 2633) (150Lb ANSI B16.5) (150Lb ANSI B16.5)
Manometer
EUPZ-07
Filter monitor
EUPZ-08
Differential pressure gauge (0-500 Pa) (type Dwyer Magnahelic, recessed in door)
EUPZ-19
Earthing cable, (for fan ECMB)
EULZ-26
Water trap, (possitive pressure max 3000 Pa)
EUMZ-01
Replacement filter (for filter EMCF)
EMAZ-03-bb-cc
Unit size (bb) 06, 12, 18 Filter class (cc) 03= short,class G3 (EU3), syntetic 05= short, class F5 (EU5), syntetic 15= long, class F5 (EU5), syntetic 16= long, class F6 (EU6), syntetic 17= long, class F7 (EU7), syntetic
4600 GB 01.09
74
For more details visit www.marinemegastore.com or call 0871 8732404
74
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Codification Air flow meter sheet (set for filter section EMCF)
EMAZ-04-bb-c
Unit size (bb) 06, 12, 18
Flexible connection (end walls) Connection piece (end walls) Counterflange (end walls) d=2,4
EMAZ-15-bb-c-d EMAZ-16-bb-c-d EMAZ-17-bb-c-d
Unit size (bb) 06, 12, 18
Material (c) 1= galvanized steel 2= stainless steel
Position (c) 1= supply air in-/ and outlet 2= exhaust air inlet (EMCO, b=3) 3= exhaust air fan outlet
Speed detector
EURZ-02-1
Base frame
EMAZ-14-bb-ccc-d-e-f
Unit size (bb) 06, 12, 18
Connection (d) 1= PG-joint, galvanized steel (not for EMAZ-17) 2= flange connection, galvanized steel 3= PG-joint, stainless steel (not for EMAZ-17) 4= flange connection, stainless steel
Damper
EMAZ-18-bb-c-d-e
Unit length, cm (ccc) 300 - 780 in step of 10 cm
Unit size (bb) 06, 12, 18
Height (d) 1= 100 mm
Position (c) 1= supply air inlet 2= exhaust air inlet (EMCO, b=3)
Version (e) 1= factory assembled Material (f) 1= galvanized steel 4= stainless steel 2343 (AISI 316)
Damper type (d) 1= with damper CEN 3, 2= with damper CEN 4, 3= with damper CEN 3, 4= with damper CEN 4,
galvanized steel galvanized steel stainless steel stainless steel
Connection (e) 1= PG-joint 2=flange Lever actuator
EUVZ-01
4600 GB 01.09
75
For more details visit www.marinemegastore.com or call 0871 8732404
75
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Control system – ControlMaster STMD
General ControlMaster is a standardised control system for airhandling units with the simplicity of an analogue system but with the potantial brought by a digital system. The control system is available in two different packages: – Built in to a compact airhandling unit – Fitted to a modular airhandling unit
Room control Supply air temperature is controlled in cascade with room air temperature. Outdoor air compensation Outdoor air temperature compensation lineally raises or lowers the supply air temperature during cold and warm spells. The compensation is adjusted on the control panel.
Standard functions Temperature Control Supply air control Supply air temperature control with PI controller. Air heater, heat recovery unit and air cooler are controlled in sequence.
Cooling recovery The heat recovery unit is used for cooling if the extract air temperature is lower than the fresh air temperature and cooling is called for. The heat exchanger is driven to maximum output.
Exhaust air control Supply air temperature is controlled in cascade with exhaust air temperature.
4600 GB 01.09
76
For more details visit www.marinemegastore.com or call 0871 8732404
76
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Control system – ControlMaster STMD Operation The airhandling unit is normally started by the built in clock. A Off-Local-Remote switch and start/stopp buttons are also provided in the front of the control cabinet. Fresh air and exhaust dampers are normally opened before the fans are started. When the fans are stopped or in the event of a power failure the dampers are closed. Where the unit includes heat recovery, the supply air fan is started after the exhaust air fan. Fans are available with single speed motors, two speed motors with separate windings, two speed motors Dahlander connected or with frequency control. Alarms Alarms are indicated in the front of the control panel and a general alarm output is provided. Filters Filter monitors provide alarms when the filter pressure drop exceed the preset value which is adjustable. Air flow proving Sensor provides a signal for alarm when the air flow rate falls below the set value. Fire and smoke The unit can be fitted with functions to provide protection against the spread of fumes and smoke. As standard the unit is stopped and any smoke dampers are closed. Frost protection A temperature sensor placed in a coil tube. If the lower temperature limit is passed the unit is stopped and an alarm is activated.
Other alarms The unit can be fitted with other external sensors which can be connected as alarms. The rotary heat exchanger is supervised with a rotation switch which gives an alarm if no rotation is detected when start signal has been given. Electrical equipment is delivered as standard for 3x400V 50-60 Hz 4-core but prepared for 5-core. The panel includes the following components as appropiate: – Main contactor, safety switch – Automatic fuses for the control circuits and for electric heaters – Contactors for fans, pumps and electric heater groups – Control circuit transformer, 24V AC – Relays – Motor protection relays with thermal and magnetic switching – Inputs and outputs for external sensors and actuators – Outputs for general external alarms – Control equipment for heaters – Documentation – Drawings and listings Testing Every panel is functionally tested before delivery. Parameters and set-points are also adjusted as far as possible. Standards EN 60 204, electrical equipment for industrial machines EN 60 439-1, electrical equipment for max. 1000V AC. IEC-750, Rules for wiring diagram nomenclature IEC-617-7, Graphic symbols for electrical diagrams. EMC Directive 89/336/EEC Low voltage directive 72/23/EEC Environmental demands of the panel All components in the panel are suitable for use within the range 0-50°C. If lower temperatures can be expected at the panels location then some form of additional heat must be provided.
4600 GB 01.09
77
For more details visit www.marinemegastore.com or call 0871 8732404
77
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Control system – ControlMaster STMD Temperature sensors
STMZ-01-bb-c-d-e
Air temperature sensors, Pt100 or Pt1000 elements with or without transmitter. Available for duct- or wall mounting, with 2,3 or 4 conductors. Manufacture: PAAB or Honeywell
Filter monitor
STMZ-18-b-c
A pressure switch which gives an alarm if pressure drop over filter exeeds setpoint. Manufacture: Dungs
Motor Surveillance Humidity sensors
STMZ-02-b-c-d
Humidity sensors with transmitter or 0-10V. Duct- or wall mounting. Manufacture: Siemens
STMZ-20-b-c
Ampere meters or running-time meters placed in cabinet front. Manufacture: Tälje
Damper actuators Frostprotection sensors
STMZ-03-b-c-d
Water temperature sensors, Pt100 or Pt1000 elements with or without transmitter, or with relay module. To be mounted in coil tube Manufacture: PAAB, Regin or Calectro
STMZ-27-bb-c-d-e
Actuators for shutoff dampers, guide vanes or smoke dampers Modulating or 2-position with endswitch. With or without spring return Manufacture: Siemens, Belimo
External fans Level switch
A switch used to set an alarm level in the drain tray.
Pressure sensor
STMZ-30-b-c-d-eee-fff
STMZ-04-b-c Starting equipment for fans not in AHU. State, type of motor, any motor surveillance, and running current. Manufacture: ABB
STMZ-07-b-c-d
Pressure sensors available in different ranges, 0-10V Manufacture: Micatrone
Lighting in control cabinet
STMZ-31-b
A flourecent lighting tube with service socket. Manufacture: Rittal Flow sensor
STMZ-08-b-c-d
Pressure sensor used with Q-nozzle to measure air flow available in different ranges, 0-10V Manufacture: Micatrone
Connection of AHU lighting
Fan monitor
Service socket in control cabinet
STMZ-17-b-c
A pressure switch which gives an alarm if fanbelts break Manufacture: Dungs
STMZ-32
Fuse and cabling for AHU lighting EMAZ-09, EUAZ-09
STMZ-33
Fuse and service socket 1x230V
Solenoid valve for humidifier
STMZ-34
Manufacture: Bürkert
4600 GB 01.09
78
For more details visit www.marinemegastore.com or call 0871 8732404
78
EMAA Air conditioning unit
For more details visit www.marinemegastore.com or call 0871 8732404
Control system – ControlMaster STMD Valve
STMZ-36-b-c-ddd-e
Valve and actuator, 2 or 3 way with 0-10V or 4-20 mA control signal.
Alarm powerfail
STMZ-58
A relay wich triggers when control voltage drops Digital input remote start
Kvs range: 0.25 – 40 Manufacture: Johnson Controls, Honeywell
Component labels
An input where you are able to start the AHU from a remote position. STMZ-44-1
Plastic signs with component code White signs with black text Frequency inverter Frequency inverter for variable speed drive 0.5 – 2 kW ACS140 2.7 – 33 kW ACS400 40 – 50 kW ACS600 Available in 400-500 V or 690 V, IP21 or IP54 Manufacture: ABB
Cable glands
STMZ-59-1
Powersupply to external damper actuators STMZ-60 Used to control smoke dampers and works parallell to shutoff dampers DKHD interlock
STMZ-61
An relay that interlocks DKHD-boxes when the supply fan is not running.
STMZ-55-b-c-d
Flange with cable glands mounted on control cabinet
Main isolator in control cabinet door
STMZ-56
An isolator which locks the control cabinet door in ’ON’position Manufacture: ABB
Connection of motor condensation heater STMZ-57 A heater element in the fan motor, which is active when the fan is not running
4600 GB 01.09
79
For more details visit www.marinemegastore.com or call 0871 8732404
79
Teleskop Reklambyrå AB 01.09.17 4600 GB
For more details visit www.marinemegastore.com or call 0871 8732404
Fläkt Woods AB SE-551 84 Jönköping Sweden Phone: Int +46 36-19 30 00 Telefax: Int +46 36-19 31 88 www.fläktwoods.com
For more details visit www.marinemegastore.com or call 0871 8732404
80