Assembly hall Technical information, Stage Plan & Floor Plan

Page 1

ASSEMBLY HALL TECHNICAL INFORMATION LIGHTING Permanent fixed lighting rig on 48 Channel Thomas par Trusses (one Truss FOH and one Onstage) consisting of a 5 colour wash (Lee filters 106 Primary Red, 119 Dark Blue, 135 Deep Golden Amber, 116 Medium Blue Green and 126 Mauve) 6 Source 4 Zoom 15/32 profiles mounted on top of the FOH Truss All dimmers are patched one-to-one For more details please see LX rig plan below or at www.worthingtheatres.co.uk follow links on right to contact us, technical then venue LIGHTING CONTROL Zero 88 Bull Frog Lighting Desk 96 Channel Lighting Desk with 1024 DMX control for up-to 24 moving light fixtures DMX Patch to Control Room and Auditorium Mixing Position DIMMING Strand Permus and Green Ginger Wall Rack 60 Dimmers SPOTLIGHTS AND OPERATORS 2 Pani HMI 1202 Followspots Positioned either side of the control room at the rear of auditorium LANTERN STOCK We have a limited lantern stock which should accommodate most productions and events for more detail please contact the technical department HOUSE LIGHTS CONTROL House lights can be controlled from control panels in the Control room, Cloakroom or Backstage Fade time of 7seconds House lights can be controlled via DMX on the Lighting Desk

SOUND MIXING DESK

Matthew Pike, Theatre Technician - August 2014


Yamaha LS9 32 Mixing Position can either be in the control room or at the Back of the

auditorium (position confirmed in advance) PATCHING 12 Inputs sends from Upstage Left to Control room 7 additional Input sends around the Building 4 amplified returns to Upstage Left from Control room CAT 5E Sends from Upstage Left to Auditorium Mixing Position F.O.H. SPEAKERS DB technologies Speaker Array hung above the first stage level DVA S10 plus 4 x DVA T4.

MONITOR AMPLIFIERS Harrison X600 Amplifiers GRAPHIC AND EFFECTS UNITS Front of House: Behringer 31 band graphic EQ FBQ6200 Monitors: Behringer 31 band graphic EQ FBQ3102 Alesis Miniverb 4 Behringer Feedback destroyer DSP1124P

SOUND EQUIPMENT PLAYBACK SONY Cassette Deck TCKB8205 SONY MINIDISC Player MDS-JE330 DENON CD PLAYER DCD-425 MICROPHONES

7 Shure SM58 5 Pulse DM-520 Dynamic 2 Pulse PLS00033 Dynamic 2 Rode M3 Condensor RADIO MICROPHONES AKG HT40 Handheld

Matthew Pike, Theatre Technician - August 2014


D.I. BOXES

3 EMO Mono Passive DI MICROPHONE STANDS 10 Long Boom Microphone stand 2 Short Boom Microphone Stands 3 Table Microphone Stand FOLDBACK 4 JBL JRX100 12 inch Passive Monitors

SOUND CABLES We have Limited Cable stock which should accommodate most productions and events for more detail please contact the technical department

CONSOLE POSITIONS

Rear of auditorium MULTICORE RUNS

Along auditorium west wall on guttering hooks. Length approx. 45m

POWER 63 Amp Single Phase CEEFORM under stage accessed from Downstage Left 100 Amp 3 Phase through 125 Amp CEEFORM Upstage Right 3 Double 13amp Sockets in Dip-traps in the stage

STAGE AND RIGGING STAGE HARDWARE 6 12.5kg Hall Stage Weight 10 sandbags 1 Art Deco Style screen that can be used as a backdrop for smaller events

Matthew Pike, Theatre Technician - August 2014


FLYING AND RIGGING POINTS Thomas par Trusses Front of House and Onstage both with under rigged bar for addition lighting or scenery cloths

These bars are limited to 100Kg SWL 1 Winch bar mid-stage limited to 100kg for scenery cloths and masking SOFT MASKING 1 sets of Gold Split Tabs STAGE DIAMENSIONS The stage is an open stage consisting of 4 stepped levels Level 1 Front edge: 11.28m Back Edge: 13.10m Depth: 3.65m Height from floor level: 1.04m Level 2 Front edge: 13.10m Back Edge: 12.38 Depth: 3.35m Height from floor level: 1.52m Level 3 Front edge: 12.38m Back Edge: 10.90m Depth: 2.13m Height from floor level: 1.77m Level 4 Front edge: 10.90m Back Edge: 10.05m Depth: 1.52m Height from floor level: 2.22m

COMMUNICATIONS TALKBACK

Matthew Pike, Theatre Technician - August 2014


There are a number of headset points around the stage and building used for communication during performances Points are located at the following places: Mid-Stage Left Mid-Stage Right Lighting Desk in Control Room Sound Desk in Control Room Followspot Positions Front of House Control Position

SHOW RELAY SYSTEMS Each Dressing room has a speaker that is feed by a relay microphone mounted above the stage

ACCESS AND PARKING Through slip road at the rear of the venue in Chapel Road between Museum and Town Hall STAGE DOOR ACCESS Via back door stage door until main doors open, then via main doors

BAND ACCESS TO STAGE Via back door stage door until main doors open, then via main doors

VEHICLE PARKING Large car park alongside venue onsite parking extremely limited and regulated please check in advance of arrival

VENUE FACILITIES DRESSING ROOMS 4 Unisex Dressing rooms with hot and cold water and 13 amp power source

There is limited Wi-fi in the Richmond Rooms Foyer & Main Auditorium BACKSTAGE FACILITIES

1 Unisex Shower backstage 1 Male and 1 Female Toilet

Matthew Pike, Theatre Technician - August 2014



= Public areas

Assembly Hall and Richmond Room - Ground Floor

= Restricted access

The fire assembly point is in the North West corner of the staff car park to the rear of Worthing Town Hall and Portland House (off Stoke Abbott Road) Ladies

Gents Note : These plans are diagrammatic - do not scale from plans (Last updated 09-12-2014)

Bar

Richmond Room Yard

N

Floor plans: Steve Collins, Adur & Worthing Councils

Wine Store

Store

Cloakroom

Preparation Room Ladies

Beer Store

Up Up

Bar Gents

Kitchen

Office

Up

Covered yard

Up

Toilets

Ramped Accessible Access Entrance

Up Gents

Up

Line of first floor balcony

Cloakroom Up

Dressing Room 4 Dressing Room 3

Assembly Hall

Stage

Entrance foyer

Dressing Room 2

Toilets

Store

Dressing Room 1

Manager

Up

Box Office

Up

Ladies Ladies Up

Bike Store

Store

Store

Store (Assembly Hall furniture)

Bike Store Store

Access entrance to Assembly Hall and theatre seating storage (G.31)

No staff access

Ramped Accessible Access

Up

Stoke Abbott Road Entrance


= Public areas

Assembly Hall and Richmond Room - First Floor

= Restricted access

The fire assembly point is in the North West corner of the staff car park to the rear of Worthing Town Hall and Portland House (off Stoke Abbott Road) Note : These plans are diagrammatic - do not scale from plans (Last updated 09-12-2014) Flat roof

N

Floor plans: Steve Collins, Adur & Worthing Councils

Roof of Richmond Room Flat roof Flat roof

Flat roof

Flat roof

Landing Up Up

Flat roof

Void over Stage

Void over Assembly Hall auditorium

Void over entrance foyer

Up Up Landing Void

Worthing Town hall

Canopy over entrance

First floor tiered seating


= Public areas

Assembly Hall and Richmond Room - Second Floor

= Restricted access

The fire assembly point is in the North West corner of the staff car park to the rear of Worthing Town Hall and Portland House (off Stoke Abbott Road) Note : These plans are diagrammatic - do not scale from plans (Last updated 09-12-2014) Flat roof

N

Floor plans: Steve Collins, Adur & Worthing Councils

Roof of Richmond Room Flat roof Flat roof

Flat roof

Flat roof

Flat roof

Flat roof

Void over Stage

Void over Assembly Hall auditorium

Void over first floor tiered seating

Flat roof behind parapet wall

Projection room

Store

Flat roof

Void

Worthing Town hall

Canopy over entrance

Store


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.