As per clause C2.7, the storeroom/ Strongroom has ben fire separated from the visible storage and carpark
Class 7a/7b Fire wall of type C construction requires an FRL of 90/90/90 Visible storage has been fire separated from both the storeroom and carpark as per clause C2.7
Carpark has been fire separated from both storage rooms as per clause C2.7
Section - 1:50 As per clause J1.3, roof consists of a typical metal cladding system. Insulation must provide a total R-value of 3.16 to achieve the minimum R-Value of 3.7 Service space provided throughout ceiling. It is of note that a ring main service system has been utilised within each level due to the curved nature of the building. As per clause F1.1, a stormwater drainage system has been provided in compliance with AS 3500.3. Water is collected by gutters stretching the length of the building and drained into underground soakwells All glazing within the building consists of 12.76mm Grey Solarshield single glazing manufactured by National Glass. As per clause J2.4, the glazing upon the south eastern face on the second floor has been deemed to be compliant. However, as calculated in accordance with J2.4, glazing upon the North Western face has been considered to be non compliant. A reduction in the size of the window has been proposed. As per clause C2.9, the storage room of class 7a Type C must be separated from the class 9b, type A construction above by a floor with an FRL of at least 120/120/120 Compliant Stair provided in accordance with AS 1428.1 As per clause C2.9, the ceiling above the Class 6 giftshop requires an FRL of 180/180/180.
Storage Room Fire Separated as per clause C2.7 by walls possessing an FRL of 120/120/120.
As per clause C2.9, the ceiling above the class 9b museum requires an FRL of 120/120/120 A false ceiling has been used in order to provide space for the ring main service system on the ground floor.
All services penetrating fire walls must do so in compliance with C3.9
Gift Shop Fire Separated as per clause C2.7 by walls possessing an FRL of 120/120/120.
Accessible and Ambulant Water Closet - Plan and Section - 1:50 2500mm 800mm Suspended ceiling allows for lighting and ventilation Tile Finnish on all walls
615
Grab rails 50mm from wall 40mm thick
980mm
Cistern, flush buttons, backrest 450
660
Non-slip Tile flooring
900mm
Non-slip tile flooring
1400mm distance from anything else
4750mm 3400mm
835mm
450
420
1460mm
250 650
Ambulant Water Closet Section - 1:50
Hand Basin Distance to tap: 300mm, Space under basin provided
Non-slip tile Flooring
900mm 98
0m
Ambulant Water Closet Plan - 1:50 Cistern with Grab rail continues aluminium past Cistern as per backrest AS 1428.1
Suspended Ceiling allows for lighting and ventilation
Signage marking unisex ambulant toilet as per clause D3.6
m
Corridor providing access
4550mm
500
825mm 670
1100mm 650mm
470
900mm
1050mm
570
1425mm 805mm 600
4550mm corridor providing access
Grab rail 50mm from wall 40mm thick
Open corridor outside toilet
450
Hand basins Distance to tap: 300mm, Space under basin provided
360 470 Non-slip tile Flooring
Accessible Water Closer Section - 1:50
Accessible Water Closet Plan - 1:50