As per clause C2.7, the storeroom/ Strongroom has ben fire separated from the visible storage and carpark

Class 7a/7b Fire wall of type C construction requires an FRL of 90/90/90 Visible storage has been fire separated from both the storeroom and carpark as per clause C2.7

Carpark has been fire separated from both storage rooms as per clause C2.7




Section - 1:50 As per clause J1.3, roof consists of a typical metal cladding system. Insulation must provide a total R-value of 3.16 to achieve the minimum R-Value of 3.7 Service space provided throughout ceiling. It is of note that a ring main service system has been utilised within each level due to the curved nature of the building. As per clause F1.1, a stormwater drainage system has been provided in compliance with AS 3500.3. Water is collected by gutters stretching the length of the building and drained into underground soakwells All glazing within the building consists of 12.76mm Grey Solarshield single glazing manufactured by National Glass. As per clause J2.4, the glazing upon the south eastern face on the second floor has been deemed to be compliant. However, as calculated in accordance with J2.4, glazing upon the North Western face has been considered to be non compliant. A reduction in the size of the window has been proposed. As per clause C2.9, the storage room of class 7a Type C must be separated from the class 9b, type A construction above by a floor with an FRL of at least 120/120/120 Compliant Stair provided in accordance with AS 1428.1 As per clause C2.9, the ceiling above the Class 6 giftshop requires an FRL of 180/180/180.

Storage Room Fire Separated as per clause C2.7 by walls possessing an FRL of 120/120/120.

As per clause C2.9, the ceiling above the class 9b museum requires an FRL of 120/120/120 A false ceiling has been used in order to provide space for the ring main service system on the ground floor.

All services penetrating fire walls must do so in compliance with C3.9

Gift Shop Fire Separated as per clause C2.7 by walls possessing an FRL of 120/120/120.


Accessible and Ambulant Water Closet - Plan and Section - 1:50 2500mm 800mm Suspended ceiling allows for lighting and ventilation Tile Finnish on all walls

615

Grab rails 50mm from wall 40mm thick

980mm

Cistern, flush buttons, backrest 450

660

Non-slip Tile flooring

900mm

Non-slip tile flooring

1400mm distance from anything else

4750mm 3400mm

835mm

450

420

1460mm

250 650

Ambulant Water Closet Section - 1:50

Hand Basin Distance to tap: 300mm, Space under basin provided

Non-slip tile Flooring

900mm 98

0m

Ambulant Water Closet Plan - 1:50 Cistern with Grab rail continues aluminium past Cistern as per backrest AS 1428.1

Suspended Ceiling allows for lighting and ventilation

Signage marking unisex ambulant toilet as per clause D3.6

m

Corridor providing access

4550mm

500

825mm 670

1100mm 650mm

470

900mm

1050mm

570

1425mm 805mm 600

4550mm corridor providing access

Grab rail 50mm from wall 40mm thick

Open corridor outside toilet

450

Hand basins Distance to tap: 300mm, Space under basin provided

360 470 Non-slip tile Flooring

Accessible Water Closer Section - 1:50

Accessible Water Closet Plan - 1:50