/82731c1c60e16093e6f9297f1e05b061

Page 1

Operating Manual Electronical Babyscale M10614

ADE GmbH & Co. Hammer Steindamm 27 – 29 D – 22089 Hamburg Fax E-mail:

+49(40)432776-0 +49(40)432776-10 info@ade-hamburg.de


Contents

Contents .................................................................................................................................................. 1 Components and Features ...................................................................................................................... 2 Panel: ..................................................................................................................................... 2 Installation ............................................................................................................................................... 3 Mounting the baby tray........................................................................................................... 3 Power Supply ......................................................................................................................... 3 Carrying the assembled baby scale....................................................................................... 3 To use the scale ...................................................................................................................................... 3 Time and date setting............................................................................................................. 3 Time ....................................................................................................................................... 3 Date........................................................................................................................................ 3 Weighing ................................................................................................................................ 4 Memory function..................................................................................................................... 4 Recall function........................................................................................................................ 4 Weight difference ................................................................................................................... 4 Tare function .......................................................................................................................... 4 Hold function .......................................................................................................................... 4 Weighing Toddlers ................................................................................................................. 4 Other display symbols............................................................................................................ 5 Cleaning and Maintenance...................................................................................................................... 5 Safety advice.......................................................................................................................... 5 Cleaning advice...................................................................................................................... 5 Warranty - Liability ................................................................................................................. 5 CE Declaration of Conformity................................................................................................. 5 Technical Data......................................................................................................................................... 6

1

050100-Rev000-M10614


Components and Features

DIFFERENCE

DIFFERENCE of weight between current and last weighing

Adjust date & time/ Change into HOLD function

ADJ/HOLD

RECALL

RECALL stored data of last weighing

SET date & time / Change into TARE function

SET/TARE

MEMORY

Weight and relevant data storing Date & Time / Weighing mode

Clock/Weight

Display shuts off automatically in time mode if inactive for 30 seconds. To light up display, press any key to continue

Panel: 1) REC

Recall indication

2) DIF

Difference indication

3) KG

Kg unit indication

4) LB.OZ

lb/oz unit indication

050100-Rev000-M10614

2


Installation Mounting the baby tray -

Connect the two parts of the baby tray by simple insertion.

-

Now slide baby try on to the platform.

Power Supply -

By batteries (not included), 4 x Mignon AA 6V) or

-

mains adapter (not included), output 6-9V 30mA, polarity -/+

Insert the batteries in the battery compartment underneath the platform. CAUTION: Strictly follow the right polarity +/In case of using AC adapter take care to use a suitable one which can be connected on the backside of the display. Carrying the assembled baby scale Please lift the scale by the platform NOT the baby tray. To use the scale Time and date setting Display indicates time (hrs 01-24 and min. 01-60) and the date (day 01-31 and month 01-12). To switch between time & date the electronic part need abt. 5 seconds. Time -

Press SET/TARE button. The two digits right hand start blinking

-

Adjust minutes and confirm by pressing ADJ/HOLD button.

-

Press SET/TARE button. The two left hand digits start blinking

-

Adjust hours and confirm by pressing ADJ/HOLD

Date -

Press SET/TARE button. The two left hand digits start blinking.

-

Adjust day and confirm by pressing ADJ/HOLD button.

-

Press SET/TARE button. The two right hand digits start blinking.

-

Adjust month and confirm by pressing ADJ/HOLD button.

For final confirmation press SET/TARE button again.

3

050100-Rev000-M10614


Weighing -

Choose weighing mode first. There is a slide switch for kg/lb/oz in the bottom of the scale. To select kg unit, please push the switch upward For lb,oz unit, just push it downward.

-

Press button CLOCK/WEIGHT and switch into weighing mode. If you are in kg weighing mode display shows first ‚8888’ to define the zero point automatically. As soon as the scale comes to `0.00´ weighing procedure can be started.

Put the baby on the tray. The scale will display the weight of the baby. To return to time mode press Clock/ Weight button. Memory function As soon as the weighing result is stable press MEMORY key, display will flash twice and the data will be stored. The stored data will remain stored until the next data is stored (which includes weight and time mode.) Recall function Press RECALL key. Display will recall the stored data. Display sequences will be weight followed by date followed by time. The data can be always recalled both in time mode and weight mode. Weight difference Being in weight mode another weighing procedure has been done. Press DIFFERENCE button and the display will show the weight difference compared to last weighing. Display sequences will be weight difference followed by date followed by time. (Weight difference could also be a negative value!!) Tare function Make sure you are in weighing mode. Any object that you might like NOT to influence the weighing result (e.g. nappy, towel, paper) you may place on the tray to put these weights under TARE. Put objects on the tray, press TARE button and after the display is showing `0.00´ put the baby on the tray. The scale will only indicate the weight of the baby. Hold function -

Make sure you are in weighing mode

-

Before putting the baby on the tray for weighing press ADJ/HOLD button.

-

Put the baby on the tray

-

Before weight is stable, the arrow will keep flashing. Once the weight is stable the display will show and HOLD.

-

Even if the baby has been taken from the tray the result is still displayed for taking notes.

To disable HOLD function press ADJ/HOLD button. Weighing Toddlers Toddlers being already able to stand on the scale can also be weighed up to a maximum capacity of 20 kg. Just slide the baby tray away from the platform and store in a safe place. Place the weighing platform on an even and safe ground before you start weighing the toddler.

050100-Rev000-M10614

4


Other display symbols In case `ERR´ is indicated the scale is overloaded (max. capacity 20 kg). In case `Lo´ is displayed the batteries are flat and need replacement. Negative value indication (kg unit) `002´. Negative value indication (lb,oz unit) `0.0 ½´ Cleaning and Maintenance Safety advice -

ADE scales are instruments of high precision. Please handle your scale with care. Do not drop it, jump on it or drop heavy objects onto it.

-

Place and use the scale on a safe and even ground surface to prevent accidents.

-

Do not get the scale wet or store it in a very humid place as this might cause damage to the PC board.

Cleaning advice For cleaning just take a damp cloth or common disinfection products.. Do not use any aggressive cleaning fluids. Warranty - Liability ADE will repair or replace this product within a period of 2 years from date of delivery applying to defects occurred due to poor material or workmanship (presentation of invoice is necessary). All moveable parts – batteries, cables, mains units, rechargeable batteries etc. – are excluded. Warranty does not include natural wear, damages caused by incorrect or negligent handling, overuse or unsuitable or improper storage. The cost of transport will be borne by the customer should the equipment be located anywhere other then the customer’s premises. In the event of transport damage, claims under warranty can be accepted subject to using the complete original packaging and the equipment secured the way it was packed and secured originally. All the packaging should therefore be retained. Any warranty claim will be rejected if the equipment is opened by persons not authorized expressively by ADE to do so. Customers abroad are kindly requested to contact their local dealer for any warranty claim, customer service and spare parts. Any legally guided customer rights are not affected by this warranty agreement.

CE Declaration of Conformity It is hereby certified that this product meets the basic safety requirements laid down in the Directive of the Council applicable to the harmonisation of the legal provisions of the member states with regards to the electromagnetic compatibility (89/336/EEC).

5

050100-Rev000-M10614


Technical Data •

Removable Baby tray

Baby tray: 560 x 105 x 275 mm

LCD Display, 25 mm

Max. Capacity: 20 kg by 10 g division

Unit function kg/ lb

Tare function

Memory function

Recall function

Difference function

Date and time indication

Weight: abt. 3,5 kg

Supplier:

050100-Rev000-M10614

ADE GmbH & Co. Hammer Steindamm 27 – 29 D – 22089 Hamburg Germany