Insect Rearing Chamber MTIRC1000
Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: info@newmeditech.com. Website: www.newmeditech.com
Insect Rearing Chamber MTIRC1000 Product Overview/Applications The IRC series insect rearing chambers are designed with insect rearing as the primary application. This chamber can be used for other research studies as well. Meditech chambers are widely used among Drosophila and Mosquito researchers and offer state of the art technology for pursuing various research studies around the globe. Quiet Operation Meditech chambers utilizes quiet and highly efficient fans. Locating these chambers in laboratory workspaces is a viable option. Simple Serviceability Refrigeration technicians are not required during chamber service, since no refrigeration equipment is used on this model. All the components of thermo electric based chambers can be diagnosed and serviced within minutes. The Ultrasonic humidifier used by Meditech can be removed and installed in less than a minute. All operates on 12 /24 Volts non hazardous applications Options Available Chart Recorder Timed Lighting CO2 Data Loggers Dryers Ultrasonic Humidification Greatly Reduced Direct and Indirect Energy Loads The IRC Series chambers utilize less energy than comparable insect rearing chambers and introduce less impact upon building cooling systems. This efficiency “dual benefit” allows our chambers to be located in spaces unsuitable for other chambers. Electrical energy savings by the IRC Series vs. steam boiler equipped chambers can easily amount to hundreds or even thousands of dollars saved per year.
Refrigeration Reliable Cooling Redundancy Each Meditech series chamber includes multiple, independent thermoelectric cooling units. There is a 7 year warranty on cooling components. Meditech chambers to maintain temperature even if the chamber suffers multiple failures. This is not possible by any other refrigeration based chamber. Superior Control and Uniformity The optional ultrasonic humidification system provides excellent humidity control and avoids hot spots seen during chamber mapping of steam boiler equipped chambers. Thermoelectric cooling and automatic switching system from cooling to heating control provide consistent results throughout the available temperature range. Standard control at the sensor in these chambers is ±0.2°C and ±0.3%RH. Services and Warranties We offer 24 hour technical support throughout the lifetime of your Insect Rearing chamber. In addition to standard warranties, we also offer extended warranties for cooling components, parts and labour. Meditech also provide qualifications, validations and preventive maintenance services at an additional cost.
Model No
Temperature Range (°C)
Interior Capacity
Interior Dimensions (WxDxH)
Exterior Dimensions (WxDxH)
Electrical Service
Weight
MTIRC12
10°C to +60°C
12 ft³ 339 L
29.75” x 23” x 29.75” 75.57 x 58.42 x 75.57 cm
34.5” x 28.25” x 44” 87.63 x 71.75 x 111.76 cm
340 lb 154 Kg
MTIRC22
10°C to +60°C
22 ft³ 622 L
26.75” x 29” x 58.5” 148.59 x 73.66 x 73.66 cm
27.75” x 35.81” x 80.5” 70.48 x 90.95 x 204.47 cm
220/240-1Ø50Hz 120-1Ø60Hz
MTIRC32
10°C to +60°C
32 ft³ 906 L
29.5” x 29.75” x 58.25” 74.93 x 75.57 x 160.97 cm
34” x 35” x 80.5” 86.36 x 88.9 x 204.47cm
745 lb 338 Kg
MTIRC47
10°C to +60°C
47 ft³ 1330 L
47.5” x 29” x 58.5” 120.65 x 73.66 x 148.59 cm
52.88” x 35.81” x 80.5” 134.3 x 90.95 x 204.47 cm
820 lb 372 Kg
MTIRC70
10°C to +60°C
70 ft³ 1982 L
71.5” x 28.75” x 58.75” 181.61 x 73.03 x 149.23 cm
78” x 35.81” x 80.5” 198.12 x 90.95 x 204.47 cm
1220 lb 554 Kg
Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: info@newmeditech.com. Website: www.newmeditech.com
605 lb 275 Kg