EZ Plus ® Internal

Type Implant, Trip Internal C onnec tion D es ign: initial s tability in any bone quality. In dens e bone s ituations , the s elf tap-

enginee red to maximize the c onnec tion betwee n the bone and the implant, while minimizing c res tal bone los s . Platform s witc hing enhanc es c res tal bone attac hment. S urfac e: O ur S uper R B M S urfac e Treatment produc es a favorable s urfac e topography that has been proven through extens ive sy s tematic tes ting. M egaG en‘s S uper R B M S urfac e s hortens loading time and pro vides favorable res ults in any bone quality. Su

Feature: Internal Trip C onnec tion: M egaG en‘s Trip anti-rotation s truc ture will not deform until 22 0N of ins ertion torque, allowing for extreme -

u per - R B M S

r

fa

S SEM(X1000) E M (X1000)

S urgery: ved us ing the E Z Plus C ounter S ink D rill. The mount-free type handpiec e c onnec tor with a built-in c eramic ball

ce

many repeated us es . Pros thetic s : The E Z Plus sy s tem inc orporates an 11° mors e taper, pro duc ing a c onic al s eal whic h forms a c old weld betwee n the abutment and the implant. Abutment options to provide aes thetic and pros thetic exc ellenc e inc lude UC L A , Angled, Sol id, Pos t, M illing type, C eramic , and O -R ing abutments as well as various other abutment options . Pac kaging: M F: Fixture with C over S c rew

S trong In ter na l Trip™ ( Triple G roove)

S ma ll

Trip Indic ation G roove

Trip™

R e g ula r

W id e

F ixture D iameter

Type Fixture Diameter Body Length

MF

MF

Ø3.3

Ø4.0

MF

MF

Ø4.5

Ø5.0

7.0 / 8.5 / 10 / 11.5 / 13 / 15mm


S ma ll

L anc e D rill

Twis t D rill Ø 2.0

1

M G D 10 0L T EED 20 0M

R e g ula r

W id e

P ilot D rill S traight D rill Ø 2. 0 - Ø 2. 8 Ø 2. 8

P ilot D rill Ø 2. 8 - Ø 3. 3

Twis t D rill Ø 3. 3

P ilot D rill Ø 3. 3 - Ø 3. 8

Twis t D rill Ø 3. 8

P ilot D rill Ø 3. 8 - Ø 4. 3

Twis t D rill Ø 4. 3

M P D 2833L

M PD 2833L

T EED 330M

M P D 3843L

T EED 380 M

M P D 3843L

T EED 430M

T EED2 80M

2

M C S 330S

M C S 40 0N

M C S4 50N

M C S 50 0N

MT P 330L

MT P40 0L

M T P450L

MT P 50 0S

3

Ø 3. 3 7.0 8. 5 10. 0 11. 5 13.0 15.0

mm mm mm mm mm mm

E ZIS 3307C E ZIS 3308C E ZIS 3310C E ZIS 3311C E ZIS 3313C E ZIS 3315C

Ø 4. 0 E ZIR40 07C E ZIR40 08C E ZIR4010C E ZIR4011C E ZIR4013C E ZIR4015C

Ø 4. 5

Ø 5. 0

E ZIR4507C E ZIR4508C E ZIR4510C E ZIR4511C E ZIR4513C E ZIR4515C

E ZI W5 0 07C E ZI W5 0 08C E ZI W5 010C E ZI W5 011C E ZI W5 013C E ZI W5 015C

I NT E RNA L H P C onnec tor / R atc het E xtens ion

4 MEIHC 330L

1

8 7

2

6 3

S G I I E Z P lu s In te rna l S urg ic a l K it

4

s mall

s mall

M EIH C 330L

M EIR E 330L

regular / wide

regular / wide

M EIH C 40 0S M EIH C 40 0L

M EIR E 40 0S M EIR E 40 0L


S T E P 1: S traight D rilling 10 7

13

diameter in order to c reate the os teotomy. 3. 5

mm 8. 5 15 11. 5

D epth M arking of Tap D rill

S T E P 2: C ounters inking O n a c as e by bone basis , c ounters inking may be Fixture depth c an be inc reas ed by drilling deeper into the os teotomy.

S T E P 3: Tapping 11. 5 15 8. 5

M 4.0

c as e of extremely dens e bone, pre -tapping may be required prior to the plac ement of the implant.

mm

10 13

D epth M arking of Tap D rill

S T E P 4: Fixture Plac ement Us e the mount-free handpiec e c onnec tor to plac e the the ratc het wrenc h. To eas ily verify trip direc tion c oronal portion of the implant.

H andpi ec e C onnec tor

6

R atc het E xtens ion

L indermann D rill D rill E xtens ion

7

Ă˜ 2.0 S topp er D rill

7.0 T EEL 20 0M

M D E150

T EED 20 07

8. 5

10

11. 5

T EED 2010

T EED 20 08 T EED 2011

Ă˜ 2. 8 S top per D rill

7.0

8. 5

T EED 2807

10

11. 5

T EED 2810

T EED 2808

T EED 2811

8

H and D river

D irec tion Indic ator

E xtens ion P lus

M D I10 0

M R E 40 0S

TC M H D L120 0 or TC M H D S 120 0


E Z Plus ® Inter na l | Abutments La b A na lo g

C ov e r S c re w

Component to duplicate the platform in a w orking model for pros thetic s

C over S c rew s mall

EP C S 10 0

C over S c rew reg /wide

EP C S 20 0

Trip-Type

s ma ll

EIL A330

re g / w id e

EIL A40 0

H e a ling A butme nt Te mp ora ry A butme nt Ø 4. 0

Ø 5.0

Ø 6.0

C uff

Ø 4.0

Ø 5.0

Ø 6.0

3.0 mm

EPH A403

AM H A503

AM H A603

5.0 mm

EPH A405

AM H A505

AM H A605

7.0 mm

EPH A407

AM H A507

AM H A607

Pic k-up lmp re s s ion C opi ng s ma ll

re g ula r/ w id e

sm a ll

Ø 1.6

re g ula r/ w id e

Trip-Type

N on-Trip

Ø 2. 0

Trip-Type

s ma ll

re g / w id e

Trip-Type

EP TN 20 0T

E ZITH10 0T

N on-Trip

EPT H10 0T

E ZITN10 0T

S c rew

EPAS 10 0

AM AS 10 0

N on-Trip

G old A butme nt guide pin included sm a ll

Trip-Type

G uide Pin

s ma ll

re g / w id e

AEZIPT3512

AEZIPT4507

AEZIPT3516

AEZIPT4512

-

AEZIPT4516

EPIG 05S

EPIG 10R

Trip-Type

re g ula r/ w id e

N on-Trip

Trip-Type

N on-Trip

s ma ll

re g / w id e

N on-Trip

EP G A10 0T

AM G A10 0T

Trip-Type

EP G A 20 0T

AM G A 20 0T

4 Courtneay Road, East Lane Business Park, Wembley, HA9 7NA, UK T. 0208 904 6191, F. 0208 904 6250 E-mail office@megagen.co.uk, www.megagen.co.uk


Abutments | E Z Plus ® Inter na l Kerator 2 mm

H e ig ht

1 mm

Platform

Small

R/W

Small

R/W

Small

R/W

Small

R/W

Small

R/W

Small

R/W

REF Code

AT401

AS401

AT402

AS402

AT403

AS403

AT404

AS404

AT405

AS405

AT406

AS406

5 mm

4 mm

3 mm

6 mm

Male processing package included

M ulti Pos t regular/wide

E Z Pos t

Screw included

Screw included

5.0 / 5.5

regular/wide

Trip-Type Ø 5.0 C uff = 2mm

Trip-Type Ø 6.0 C uff = 2mm

1. 2 H ex

Ø 4.0

Trip -Ty p e

N on-Trip

C uff 1 mm

EPEH4155T

EP EN 4155T

C uff 2 mm

EPEH4255T

EP EN 4255T

EPEH435 5T

EP EN 435 5T

Ø 5.0

Ø 6.0

S cr e w

C uff 3 mm

E ZI M B 50 0T

E ZI M B 60 0T

E ZI M S 20 0S

C uff 4 mm

EPEH4455T

EP EN 4455T

C uff 5 mm

EPEH455 5T

EP EN 455 5T

Ø 5.0

Trip -Ty p e

N on-Trip

C uff 1 mm

AE ZP5150T

AM M P5150T

C uff 2 mm

AE ZP5250T

AM M P5250T

C uff 3 mm

AE ZP5350T

AM M P5350T

C uff 4 mm

AE ZP5450T

AM M P5450T

C uff 5 mm

AE ZP55 50T

AM M P5550T

Ø 6.0

Trip -Ty p e

N on-Trip

C uff 1 mm

AE ZP6150T

AM M P6150T

C uff 2 mm

AE ZP6250T

AM M P6250T

C uff 3 mm

AE ZP6350T

AM M P6350T

C uff 4 mm

AE ZP6450T

AM M P6450T

C uff 5 mm

AE ZP6550T

AM M P6550T

A ng le d A butme nt 15°

Screw included

25°

15°

Trip-Type

25°

N on-Trip

Ø 4.0

15° Trip -T.

25° Trip -T.

15° N on-T.

25° N on-T.

C1

EPAH4115T

EPAH4125T

-

-

C2

EPAH4215T

EPAH4225T

EPA A4215T

EPA A4225T

C4

EPAH4415T

EPAH4425T

EPA A4415T

EPA A4425T

Ø 5. 0

15° Trip -T.

25° Trip -T.

15° N on-T.

25° N on-T.

C1

EPAH5115 T

EPAH5215 T

-

-

C2

AE Z A5215T

AE Z A5225T

AM A A5215T AM A A5225T

C3

AE Z A5315T

AE Z A5325T

AM A A5315T AM A A5325T

C4

AE Z A5415T

AE Z A5425T

AM A A5415T AM A A5425T

C5

AE Z A5515T

AE Z A5525T

AM A A5515T AM A A5525T

Ø 6.0

15° Trip -T.

25° Trip -T.

15° N on-T.

C2

AE Z A6 215T

AE Z A6 225T

AM A A6 215T AM A A6 225T

C3

AE Z A6315T

AE Z A6325T

AM A A6315T AM A A6 225T

C4

AE Z A6415T

AE Z A6425T

AM A A6415T AM A A6425T

C5

AE Z A6515T

AE Z A6525T

AM A A6515T AM A A6525T

25° N on-T.

C omfor t C ap

S na p I mp res s ion

L e ve l A na lo g

Ø 4.0

AM IC 04

AM IIC 04

AM S L A450

Ø 5. 0

AM IC 05

AM IIC 05

AM S L A550

Ø 6.0

AM IC 0 6

AM IIC 0 6

AM S L A650

© 2011 Megagen Implant UK - All rights reserved. Subject to typographical and other errors.


E Z Plus ® Inter na l | Abutments S olid A butme nt

5.0 / 5.5

3. 5

M illi ng A butme nt

9.0

Ø 4.0

3. 5 mm

5.0 mm

C uff 1 mm

-

EP S 4155

C uff 2 mm

-

EP S 4255

C uff 3 mm

-

EP S 4355

C uff 4 mm

-

EP S 4455

C uff 5 mm

-

EP S 455 5

Ø 5.0

3. 5 mm

C uff 1 mm

Trip-Type

N on-Trip

Ø 5.0

Trip -Ty p e

N on-Trip

C uff 1 mm

AE ZP519 0T

AM M P5190T

C uff 2 mm

AE ZP529 0T

AM M P5290T

5.0 mm

C uff 3 mm

AE ZP539 0T

AM M P5390T

AM M S 5135

AM M S 5150

C uff 4 mm

AE ZP549 0T

AM M P5490T

C uff 2 mm

AM M S 5235

AM M S 5250

C uff 5 mm

AE ZP559 0T

AM M P5590T

C uff 3 mm

AM M S 53 35

AM M S 5350

C uff 4 mm

AM M S 5435

AM M S 5450

Ø 6.0

Trip -Ty p e

N on-Trip

C uff 5 mm

AM M S 5535

AM M S 5550

C uff 1 mm

AE ZP619 0T

AM M P6190T

C uff 2 mm

AE ZP629 0T

AM M P6290T

Ø 6.0

3. 5 mm

5.0 mm

C uff 3 mm

AE ZP639 0T

AM M P6390T

C uff 1 mm

AM M S 6135

AM M S 6150

C uff 4 mm

AE ZP649 0T

AM M P6490T

C uff 2 mm

AM M S 6235

AM M S 62 50

C uff 5 mm

AE ZP659 0T

AM M P6590T

C uff 3 mm

AM M S 6335

AM M S 6350

C uff 4 mm

AM M S 6435

AM M S 6450

C uff 5 mm

AM M S 6535

AM M S 6550 Pos t I e ve l A na lo g 9.0

C omfor t C a p

S na p I mp res s ion

N on-Trip 3. 5 mm

Ø 4.0 Ø 5.0 Ø 6.0

AM IC 04 AM IC 05 AM IC 0 6

5.0 mm

AM IIC 04

AM S L A450

AM IIC 05

AM S L A535 AM S L A550

AM IIC 0 6

AM S L A635 AM S L A650

Ø 5.0 N on-Trip

Ø 6.0 N on-Trip

C uff 1 mm

AM M S 5190T

AM M S 6190T

C uff 2 mm

AM M S 5290T

AM M S 6290T

C uff 3 mm

AM M S 5390T

AM M S 6390T

C uff 4 mm

AM M S 5490T

AM M S 6490T

C uff 5 mm

AM M S 5590T

AM M S 6590T

4 Courtneay Road, East Lane Business Park, Wembley, HA9 7NA, UK T. 0208 904 6191, F. 0208 904 6250 E-mail office@megagen.co.uk, www.megagen.co.uk


Abutments | E Z Plus ® Inter na l O c ta A butme nt

O c ta G ol d A butme nt

s mall

regular/wide

Ø 4. 8

Ø 4. 8

N on-O c ta

O c ta

2.0 mm

EP O AS 502

EP O AR 502

Plas tic s leeve white

Plas tic s leeve red

3.0 mm

EP O AS 503

EP O AR 503

IO G N10 0T

IO G O 10 0T

4.0 mm

EP O AS 504

EP O AR 504

5.0 mm

EP O AS 505

EP O AR 505

O c ta Pla s tic A butme nt O c ta Pic k up Im p ressi on

N on-O c ta

O c ta

I mp re s s ion

N on-O c ta

O c ta

Plas tic white

Plas tic red

IO PN10 0T

IO P H10 0T

G uid e Pin

O c ta

N on-O c ta

R IO G 10 0

R IO H10 0T

R IO N10 0T

R IO G 150

Ball Abutment

O c ta H e a ling C a p H e a li ng Ca p

H e a li ng S c re w

IHC 40 0T

IR C S 20 0

O c ta La b Ana log

REF Code EPBS00

Small Ø2.85 x C0.0

EPBS02

Small Ø2.85 x C2.0

EPBS04

Small Ø2.85 x C4.0

EPBS06

Small Ø2.85 x C6.0

EPBR00

R/W Ø2.85 x C0.0

EPBR00

R/W Ø2.85 x C2.0

EPBR00

R/W Ø2.85 x C4.0

EPBR00

R/W Ø2.85 x C6.0

R E F -Co d e

IO A30 0

© 2011 Megagen Implant UK - All rights reserved. Subject to typographical and other errors.


ENotes: xFe e l 速 Inter na l | Abutments ________________________________________________________ ________________________________________________________ S olid Pos t A butme nt & Pos t C a p ________________________________________________________ ________________________________________________________ ________________________________________________________ ________________________________________________________ ________________________________________________________ H e ig ht A b ut. C uff=1 A b ut. C uff=2 A b ut. C uff=3 Ca p C uff=1 Ca p C uff=2 Ca p C uff=3 ________________________________________________________ 4.0 mm IS PA401P IS PA402P IS PA403P IS P C 401 IS P C 402 IS P C 403 5.5 mm IS PA551P IS PA552P IS PA553P IS P C 551 IS P C 552 IS P C 553 ________________________________________________________ 7.0 mm IS PA701P IS PA702P IS PA703P IS P C 701 IS P C 702 IS P C 703 ________________________________________________________ ________________________________________________________ ________________________________________________________ S olid A na log S olid A butme nt & Prote c t C a p ________________________________________________________ ________________________________________________________ ________________________________________________________ H e ig ht R E F c od e 4.0 mm IS N 40 0 ________________________________________________________ 5.5 mm IS N 550 ________________________________________________________ 7.0 mm IS N 70 0 ________________________________________________________ H e ig ht A b utme nt Prote c t Ca p ________________________________________________________ 4.0 mm IS A40 0P IS P C 450 5.5 mm IS A550P IS P C 60 0 ________________________________________________________ S na p Im p res s ion C a p 7.0 mm IS A70 0P IS P C 750 ________________________________________________________ R E F -Co d e IS IC 10 0 ________________________________________________________ Pos itioning C ylin d e r ________________________________________________________ S olid s hould e r A na lo g , Pin ________________________________________________________ H e ig ht R E F -Co d e 7.0 mm IIP C 10 0 ________________________________________________________ ________________________________________________________ ________________________________________________________ B ridg e M a te ria l R E F c od e S olid s houlder analog Plas tic IS L A10 0 ________________________________________________________ Analog pin T itanium IS L A 20 0 ________________________________________________________ ________________________________________________________ ________________________________________________________ PH

S olid Pos t A b utme nt

S olid Pos t C a p

CH

U s ing :

S olid Pos t D river (M S D 430S /L)

PH

S olid A b utme nt

S olid P rote c t C a p

U s ing :

S olid D river (M S D 30 0)

S olid s houlder Analog & Pin

4 Courtneay Road, East Lane Business Park, Wembley, HA9 7NA, UK T. 0208 904 6191, F. 0208 904 6250 E-mail office@megagen.co.uk, www.megagen.co.uk


Abutments | E xFe e l 速 Inter na l O c ta G old A butme nt

O c ta A butme nt & H e a ling C a p O c ta A b utme nt: Abutment for multiple bridge teeth

A b utme nt S c re w : Inc luded IR C S 20 0 N on-O c ta

U s ing :

O c ta

1. 2 H ex H and driver ( TC M H D L120 0 or TC M H D S 120 0) or 1. 2 H ex R ight angle driver (M D R120)

N on-O c ta

O c ta

Plas tic s leeve white

Plas tic s leeve red

IO G N10 0T

IOG O 10 0T

U s ing :

O c ta D river (M O D 30 0)

R E F C od e

IO A 20 0

O c ta H e a ling C a p U s ing :

1. 2 H ex H and driver ( TC M H D L120 0 or TC M H D S 120 0) or 1. 2 H ex R ight angle driver (MD R120)

O c ta H e a ling C a p

S c re w 2. 0 mm x 0.40 pitc h

O c ta Pla s tic A butme nt

IHC 40 0T

IA AS 60 0

A b utme nt S c re w : Inc luded IR C S 20 0 N on-O c ta

U s ing :

O c ta

Im p ressi on & La b A na lo g

1. 2 H ex H and driver ( TC M H D L120 0 or TC M H D S 120 0) or 1. 2 H ex R ight angle driver (M D R120)

N on-O c ta

O c ta

Plas tic white

Plas tic red

IO PN10 0T

IO P H10 0T

O c ta Im p re s s ion C opi ng P ic k-U p ty p e 15mm G uide pi n: inc luded R IO G 150

O c ta A na log : analog for O c ta Abutment

A butme nt S cr e w

U s ing :

1. 2 H ex H and driver ( TC M H D L120 0 or TC M H D S 120 0) or 1. 2 H ex R ight angle driver (MD R120)

O c ta Im p re s si on C op ing

G uid e Pin R IO G 150

U s ing :

1. 2 H ex H and driver ( TC M H D L120 0 or TC M H D S 120 0) or 1. 2 H ex R ight angle driver (M D R120)

Angled Abutment

IA AS 60 0

O c ta G old Abutment/Healing C ap

IR C S 20 0

M ulti Pos t/G old Abutment

E XIM S 10 0

O c ta

N on-O c ta

O c ta A na log

R IO H10 0T

R IO N10 0T

IO A30 0


4 Courtneay Road, East Lane Business Park, Wembley, HA9 7NA, UK T. 0208 904 6191, F. 0208 904 6250 E-mail office@megagen.co.uk, www.megagen.co.uk