Contact MegaGen Implant UK: Telephone: 0208 904 6191 Fax: 0208 904 6250 Email: office@megagen.co.uk Website: www.megagen.co.uk Address : 4 Courtneay Road East Lane Business Park Wembley, HA9 7NA, UK
EZ Plus ® Internal
Type Implant, Trip Internal C onnec tion D es ign: initial s tability in any bone quality. In dens e bone s ituations , the s elf tap-
enginee red to maximize the c onnec tion betwee n the bone and the implant, while minimizing c res tal bone los s . Platform s witc hing enhanc es c res tal bone attac hment. S urfac e: O ur S uper R B M S urfac e Treatment produc es a favorable s urfac e topography that has been proven through extens ive sy s tematic tes ting. M egaG en‘s S uper R B M S urfac e s hortens loading time and pro vides favorable res ults in any bone quality. Su
Feature: Internal Trip C onnec tion: M egaG en‘s Trip anti-rotation s truc ture will not deform until 22 0N of ins ertion torque, allowing for extreme -
u per - R B M S
r
fa
S SEM(X1000) E M (X1000)
S urgery: ved us ing the E Z Plus C ounter S ink D rill. The mount-free type handpiec e c onnec tor with a built-in c eramic ball
ce
many repeated us es . Pros thetic s : The E Z Plus sy s tem inc orporates an 11° mors e taper, pro duc ing a c onic al s eal whic h forms a c old weld betwee n the abutment and the implant. Abutment options to provide aes thetic and pros thetic exc ellenc e inc lude UC L A , Angled, Sol id, Pos t, M illing type, C eramic , and O -R ing abutments as well as various other abutment options . Pac kaging: M F: Fixture with C over S c rew
S trong In ter na l Trip™ ( Triple G roove)
S ma ll
Trip Indic ation G roove
Trip™
R e g ula r
W id e
F ixture D iameter
Type Fixture Diameter Body Length
MF
MF
Ø3.3
Ø4.0
MF
MF
Ø4.5
Ø5.0
7.0 / 8.5 / 10 / 11.5 / 13 / 15mm
S ma ll
L anc e D rill
Twis t D rill Ø 2.0
1
M G D 10 0L T EED 20 0M
R e g ula r
W id e
P ilot D rill S traight D rill Ø 2. 0 - Ø 2. 8 Ø 2. 8
P ilot D rill Ø 2. 8 - Ø 3. 3
Twis t D rill Ø 3. 3
P ilot D rill Ø 3. 3 - Ø 3. 8
Twis t D rill Ø 3. 8
P ilot D rill Ø 3. 8 - Ø 4. 3
Twis t D rill Ø 4. 3
M P D 2833L
M PD 2833L
T EED 330M
M P D 3843L
T EED 380 M
M P D 3843L
T EED 430M
T EED2 80M
2
M C S 330S
M C S 40 0N
M C S4 50N
M C S 50 0N
MT P 330L
MT P40 0L
M T P450L
MT P 50 0S
3
Ø 3. 3 7.0 8. 5 10. 0 11. 5 13.0 15.0
mm mm mm mm mm mm
E ZIS 3307C E ZIS 3308C E ZIS 3310C E ZIS 3311C E ZIS 3313C E ZIS 3315C
Ø 4. 0 E ZIR40 07C E ZIR40 08C E ZIR4010C E ZIR4011C E ZIR4013C E ZIR4015C
Ø 4. 5
Ø 5. 0
E ZIR4507C E ZIR4508C E ZIR4510C E ZIR4511C E ZIR4513C E ZIR4515C
E ZI W5 0 07C E ZI W5 0 08C E ZI W5 010C E ZI W5 011C E ZI W5 013C E ZI W5 015C
I NT E RNA L H P C onnec tor / R atc het E xtens ion
4 MEIHC 330L
1
8 7
2
6 3
S G I I E Z P lu s In te rna l S urg ic a l K it
4
s mall
s mall
M EIH C 330L
M EIR E 330L
regular / wide
regular / wide
M EIH C 40 0S M EIH C 40 0L
M EIR E 40 0S M EIR E 40 0L
S T E P 1: S traight D rilling 10 7
13
diameter in order to c reate the os teotomy. 3. 5
mm 8. 5 15 11. 5
D epth M arking of Tap D rill
S T E P 2: C ounters inking O n a c as e by bone basis , c ounters inking may be Fixture depth c an be inc reas ed by drilling deeper into the os teotomy.
S T E P 3: Tapping 11. 5 15 8. 5
M 4.0
c as e of extremely dens e bone, pre -tapping may be required prior to the plac ement of the implant.
mm
10 13
D epth M arking of Tap D rill
S T E P 4: Fixture Plac ement Us e the mount-free handpiec e c onnec tor to plac e the the ratc het wrenc h. To eas ily verify trip direc tion c oronal portion of the implant.
H andpi ec e C onnec tor
6
R atc het E xtens ion
L indermann D rill D rill E xtens ion
7
Ă˜ 2.0 S topp er D rill
7.0 T EEL 20 0M
M D E150
T EED 20 07
8. 5
10
11. 5
T EED 2010
T EED 20 08 T EED 2011
Ă˜ 2. 8 S top per D rill
7.0
8. 5
T EED 2807
10
11. 5
T EED 2810
T EED 2808
T EED 2811
8
H and D river
D irec tion Indic ator
E xtens ion P lus
M D I10 0
M R E 40 0S
TC M H D L120 0 or TC M H D S 120 0
E Z Plus ® Inter na l | Abutments La b A na lo g
C ov e r S c re w
Component to duplicate the platform in a w orking model for pros thetic s
C over S c rew s mall
EP C S 10 0
C over S c rew reg /wide
EP C S 20 0
Trip-Type
s ma ll
EIL A330
re g / w id e
EIL A40 0
H e a ling A butme nt Te mp ora ry A butme nt Ø 4. 0
Ø 5.0
Ø 6.0
C uff
Ø 4.0
Ø 5.0
Ø 6.0
3.0 mm
EPH A403
AM H A503
AM H A603
5.0 mm
EPH A405
AM H A505
AM H A605
7.0 mm
EPH A407
AM H A507
AM H A607
Pic k-up lmp re s s ion C opi ng s ma ll
re g ula r/ w id e
sm a ll
Ø 1.6
re g ula r/ w id e
Trip-Type
N on-Trip
Ø 2. 0
Trip-Type
s ma ll
re g / w id e
Trip-Type
EP TN 20 0T
E ZITH10 0T
N on-Trip
EPT H10 0T
E ZITN10 0T
S c rew
EPAS 10 0
AM AS 10 0
N on-Trip
G old A butme nt guide pin included sm a ll
Trip-Type
G uide Pin
s ma ll
re g / w id e
AEZIPT3512
AEZIPT4507
AEZIPT3516
AEZIPT4512
-
AEZIPT4516
EPIG 05S
EPIG 10R
Trip-Type
re g ula r/ w id e
N on-Trip
Trip-Type
N on-Trip
s ma ll
re g / w id e
N on-Trip
EP G A10 0T
AM G A10 0T
Trip-Type
EP G A 20 0T
AM G A 20 0T
4 Courtneay Road, East Lane Business Park, Wembley, HA9 7NA, UK T. 0208 904 6191, F. 0208 904 6250 E-mail office@megagen.co.uk, www.megagen.co.uk
Abutments | E Z Plus ® Inter na l Kerator 2 mm
H e ig ht
1 mm
Platform
Small
R/W
Small
R/W
Small
R/W
Small
R/W
Small
R/W
Small
R/W
REF Code
AT401
AS401
AT402
AS402
AT403
AS403
AT404
AS404
AT405
AS405
AT406
AS406
5 mm
4 mm
3 mm
6 mm
Male processing package included
M ulti Pos t regular/wide
E Z Pos t
Screw included
Screw included
5.0 / 5.5
regular/wide
Trip-Type Ø 5.0 C uff = 2mm
Trip-Type Ø 6.0 C uff = 2mm
1. 2 H ex
Ø 4.0
Trip -Ty p e
N on-Trip
C uff 1 mm
EPEH4155T
EP EN 4155T
C uff 2 mm
EPEH4255T
EP EN 4255T
EPEH435 5T
EP EN 435 5T
Ø 5.0
Ø 6.0
S cr e w
C uff 3 mm
E ZI M B 50 0T
E ZI M B 60 0T
E ZI M S 20 0S
C uff 4 mm
EPEH4455T
EP EN 4455T
C uff 5 mm
EPEH455 5T
EP EN 455 5T
Ø 5.0
Trip -Ty p e
N on-Trip
C uff 1 mm
AE ZP5150T
AM M P5150T
C uff 2 mm
AE ZP5250T
AM M P5250T
C uff 3 mm
AE ZP5350T
AM M P5350T
C uff 4 mm
AE ZP5450T
AM M P5450T
C uff 5 mm
AE ZP55 50T
AM M P5550T
Ø 6.0
Trip -Ty p e
N on-Trip
C uff 1 mm
AE ZP6150T
AM M P6150T
C uff 2 mm
AE ZP6250T
AM M P6250T
C uff 3 mm
AE ZP6350T
AM M P6350T
C uff 4 mm
AE ZP6450T
AM M P6450T
C uff 5 mm
AE ZP6550T
AM M P6550T
A ng le d A butme nt 15°
Screw included
25°
15°
Trip-Type
25°
N on-Trip
Ø 4.0
15° Trip -T.
25° Trip -T.
15° N on-T.
25° N on-T.
C1
EPAH4115T
EPAH4125T
-
-
C2
EPAH4215T
EPAH4225T
EPA A4215T
EPA A4225T
C4
EPAH4415T
EPAH4425T
EPA A4415T
EPA A4425T
Ø 5. 0
15° Trip -T.
25° Trip -T.
15° N on-T.
25° N on-T.
C1
EPAH5115 T
EPAH5215 T
-
-
C2
AE Z A5215T
AE Z A5225T
AM A A5215T AM A A5225T
C3
AE Z A5315T
AE Z A5325T
AM A A5315T AM A A5325T
C4
AE Z A5415T
AE Z A5425T
AM A A5415T AM A A5425T
C5
AE Z A5515T
AE Z A5525T
AM A A5515T AM A A5525T
Ø 6.0
15° Trip -T.
25° Trip -T.
15° N on-T.
C2
AE Z A6 215T
AE Z A6 225T
AM A A6 215T AM A A6 225T
C3
AE Z A6315T
AE Z A6325T
AM A A6315T AM A A6 225T
C4
AE Z A6415T
AE Z A6425T
AM A A6415T AM A A6425T
C5
AE Z A6515T
AE Z A6525T
AM A A6515T AM A A6525T
25° N on-T.
C omfor t C ap
S na p I mp res s ion
L e ve l A na lo g
Ø 4.0
AM IC 04
AM IIC 04
AM S L A450
Ø 5. 0
AM IC 05
AM IIC 05
AM S L A550
Ø 6.0
AM IC 0 6
AM IIC 0 6
AM S L A650
© 2011 Megagen Implant UK - All rights reserved. Subject to typographical and other errors.
E Z Plus ® Inter na l | Abutments S olid A butme nt
5.0 / 5.5
3. 5
M illi ng A butme nt
9.0
Ø 4.0
3. 5 mm
5.0 mm
C uff 1 mm
-
EP S 4155
C uff 2 mm
-
EP S 4255
C uff 3 mm
-
EP S 4355
C uff 4 mm
-
EP S 4455
C uff 5 mm
-
EP S 455 5
Ø 5.0
3. 5 mm
C uff 1 mm
Trip-Type
N on-Trip
Ø 5.0
Trip -Ty p e
N on-Trip
C uff 1 mm
AE ZP519 0T
AM M P5190T
C uff 2 mm
AE ZP529 0T
AM M P5290T
5.0 mm
C uff 3 mm
AE ZP539 0T
AM M P5390T
AM M S 5135
AM M S 5150
C uff 4 mm
AE ZP549 0T
AM M P5490T
C uff 2 mm
AM M S 5235
AM M S 5250
C uff 5 mm
AE ZP559 0T
AM M P5590T
C uff 3 mm
AM M S 53 35
AM M S 5350
C uff 4 mm
AM M S 5435
AM M S 5450
Ø 6.0
Trip -Ty p e
N on-Trip
C uff 5 mm
AM M S 5535
AM M S 5550
C uff 1 mm
AE ZP619 0T
AM M P6190T
C uff 2 mm
AE ZP629 0T
AM M P6290T
Ø 6.0
3. 5 mm
5.0 mm
C uff 3 mm
AE ZP639 0T
AM M P6390T
C uff 1 mm
AM M S 6135
AM M S 6150
C uff 4 mm
AE ZP649 0T
AM M P6490T
C uff 2 mm
AM M S 6235
AM M S 62 50
C uff 5 mm
AE ZP659 0T
AM M P6590T
C uff 3 mm
AM M S 6335
AM M S 6350
C uff 4 mm
AM M S 6435
AM M S 6450
C uff 5 mm
AM M S 6535
AM M S 6550 Pos t I e ve l A na lo g 9.0
C omfor t C a p
S na p I mp res s ion
N on-Trip 3. 5 mm
Ø 4.0 Ø 5.0 Ø 6.0
AM IC 04 AM IC 05 AM IC 0 6
5.0 mm
AM IIC 04
AM S L A450
AM IIC 05
AM S L A535 AM S L A550
AM IIC 0 6
AM S L A635 AM S L A650
Ø 5.0 N on-Trip
Ø 6.0 N on-Trip
C uff 1 mm
AM M S 5190T
AM M S 6190T
C uff 2 mm
AM M S 5290T
AM M S 6290T
C uff 3 mm
AM M S 5390T
AM M S 6390T
C uff 4 mm
AM M S 5490T
AM M S 6490T
C uff 5 mm
AM M S 5590T
AM M S 6590T
4 Courtneay Road, East Lane Business Park, Wembley, HA9 7NA, UK T. 0208 904 6191, F. 0208 904 6250 E-mail office@megagen.co.uk, www.megagen.co.uk
Abutments | E Z Plus ® Inter na l O c ta A butme nt
O c ta G ol d A butme nt
s mall
regular/wide
Ø 4. 8
Ø 4. 8
N on-O c ta
O c ta
2.0 mm
EP O AS 502
EP O AR 502
Plas tic s leeve white
Plas tic s leeve red
3.0 mm
EP O AS 503
EP O AR 503
IO G N10 0T
IO G O 10 0T
4.0 mm
EP O AS 504
EP O AR 504
5.0 mm
EP O AS 505
EP O AR 505
O c ta Pla s tic A butme nt O c ta Pic k up Im p ressi on
N on-O c ta
O c ta
I mp re s s ion
N on-O c ta
O c ta
Plas tic white
Plas tic red
IO PN10 0T
IO P H10 0T
G uid e Pin
O c ta
N on-O c ta
R IO G 10 0
R IO H10 0T
R IO N10 0T
R IO G 150
Ball Abutment
O c ta H e a ling C a p H e a li ng Ca p
H e a li ng S c re w
IHC 40 0T
IR C S 20 0
O c ta La b Ana log
REF Code EPBS00
Small Ø2.85 x C0.0
EPBS02
Small Ø2.85 x C2.0
EPBS04
Small Ø2.85 x C4.0
EPBS06
Small Ø2.85 x C6.0
EPBR00
R/W Ø2.85 x C0.0
EPBR00
R/W Ø2.85 x C2.0
EPBR00
R/W Ø2.85 x C4.0
EPBR00
R/W Ø2.85 x C6.0
R E F -Co d e
IO A30 0
© 2011 Megagen Implant UK - All rights reserved. Subject to typographical and other errors.
ENotes: xFe e l 速 Inter na l | Abutments ________________________________________________________ ________________________________________________________ S olid Pos t A butme nt & Pos t C a p ________________________________________________________ ________________________________________________________ ________________________________________________________ ________________________________________________________ ________________________________________________________ H e ig ht A b ut. C uff=1 A b ut. C uff=2 A b ut. C uff=3 Ca p C uff=1 Ca p C uff=2 Ca p C uff=3 ________________________________________________________ 4.0 mm IS PA401P IS PA402P IS PA403P IS P C 401 IS P C 402 IS P C 403 5.5 mm IS PA551P IS PA552P IS PA553P IS P C 551 IS P C 552 IS P C 553 ________________________________________________________ 7.0 mm IS PA701P IS PA702P IS PA703P IS P C 701 IS P C 702 IS P C 703 ________________________________________________________ ________________________________________________________ ________________________________________________________ S olid A na log S olid A butme nt & Prote c t C a p ________________________________________________________ ________________________________________________________ ________________________________________________________ H e ig ht R E F c od e 4.0 mm IS N 40 0 ________________________________________________________ 5.5 mm IS N 550 ________________________________________________________ 7.0 mm IS N 70 0 ________________________________________________________ H e ig ht A b utme nt Prote c t Ca p ________________________________________________________ 4.0 mm IS A40 0P IS P C 450 5.5 mm IS A550P IS P C 60 0 ________________________________________________________ S na p Im p res s ion C a p 7.0 mm IS A70 0P IS P C 750 ________________________________________________________ R E F -Co d e IS IC 10 0 ________________________________________________________ Pos itioning C ylin d e r ________________________________________________________ S olid s hould e r A na lo g , Pin ________________________________________________________ H e ig ht R E F -Co d e 7.0 mm IIP C 10 0 ________________________________________________________ ________________________________________________________ ________________________________________________________ B ridg e M a te ria l R E F c od e S olid s houlder analog Plas tic IS L A10 0 ________________________________________________________ Analog pin T itanium IS L A 20 0 ________________________________________________________ ________________________________________________________ ________________________________________________________ PH
S olid Pos t A b utme nt
S olid Pos t C a p
CH
U s ing :
S olid Pos t D river (M S D 430S /L)
PH
S olid A b utme nt
S olid P rote c t C a p
U s ing :
S olid D river (M S D 30 0)
S olid s houlder Analog & Pin
4 Courtneay Road, East Lane Business Park, Wembley, HA9 7NA, UK T. 0208 904 6191, F. 0208 904 6250 E-mail office@megagen.co.uk, www.megagen.co.uk
Abutments | E xFe e l 速 Inter na l O c ta G old A butme nt
O c ta A butme nt & H e a ling C a p O c ta A b utme nt: Abutment for multiple bridge teeth
A b utme nt S c re w : Inc luded IR C S 20 0 N on-O c ta
U s ing :
O c ta
1. 2 H ex H and driver ( TC M H D L120 0 or TC M H D S 120 0) or 1. 2 H ex R ight angle driver (M D R120)
N on-O c ta
O c ta
Plas tic s leeve white
Plas tic s leeve red
IO G N10 0T
IOG O 10 0T
U s ing :
O c ta D river (M O D 30 0)
R E F C od e
IO A 20 0
O c ta H e a ling C a p U s ing :
1. 2 H ex H and driver ( TC M H D L120 0 or TC M H D S 120 0) or 1. 2 H ex R ight angle driver (MD R120)
O c ta H e a ling C a p
S c re w 2. 0 mm x 0.40 pitc h
O c ta Pla s tic A butme nt
IHC 40 0T
IA AS 60 0
A b utme nt S c re w : Inc luded IR C S 20 0 N on-O c ta
U s ing :
O c ta
Im p ressi on & La b A na lo g
1. 2 H ex H and driver ( TC M H D L120 0 or TC M H D S 120 0) or 1. 2 H ex R ight angle driver (M D R120)
N on-O c ta
O c ta
Plas tic white
Plas tic red
IO PN10 0T
IO P H10 0T
O c ta Im p re s s ion C opi ng P ic k-U p ty p e 15mm G uide pi n: inc luded R IO G 150
O c ta A na log : analog for O c ta Abutment
A butme nt S cr e w
U s ing :
1. 2 H ex H and driver ( TC M H D L120 0 or TC M H D S 120 0) or 1. 2 H ex R ight angle driver (MD R120)
O c ta Im p re s si on C op ing
G uid e Pin R IO G 150
U s ing :
1. 2 H ex H and driver ( TC M H D L120 0 or TC M H D S 120 0) or 1. 2 H ex R ight angle driver (M D R120)
Angled Abutment
IA AS 60 0
O c ta G old Abutment/Healing C ap
IR C S 20 0
M ulti Pos t/G old Abutment
E XIM S 10 0
O c ta
N on-O c ta
O c ta A na log
R IO H10 0T
R IO N10 0T
IO A30 0
4 Courtneay Road, East Lane Business Park, Wembley, HA9 7NA, UK T. 0208 904 6191, F. 0208 904 6250 E-mail office@megagen.co.uk, www.megagen.co.uk