LG Air Conditioners 2011
Tropical Multi V III
If you need a highly efficient air conditioning system in your building, VRS is the right choice for you. Wall Mounted
2Way Casstte
Tropical Multi V Mini
4Way Casstte
1Way Casstte
High Static
Tropical Multi V Water II
Low Static
Ceiling & Floor
Floor Standing - With Case
Multi V series Indoor unit
Ceiling Suspended
Floor Standing - Without Case
eco V V-Net & Accessory
Tropical Multi V III Tropical Multi V Mini
Low Noise Super light BLDC motor guarantees your enhanced comfortable indoor environment.
Office
Conversation
Library
4 way CST
Tropical Multi V Water II
Typing
4 Vanes Independent Operation
All vane operation
Air flow rate control
Multi V series Indoor unit
Vane angle control satisfies both users who like direct wind and indirect wind. and also it prevents cold air draft.
Individual vane operation
Direct air flow
Indirect air flow Individual vane angle control
eco V
Auto Elevation Grille Easy filter cleaning with elevation grille - Installed inside main body - Auto horizontal level - 4 points support - Memory for user’s level - Max. 4.5m length Memory for user’s level
Auto bottom detection
STOP Memory *Available for 24k ~ 48k Btu/h
Max. 4.5m
Auto horizontal control
Conventional 3.5m
V-Net & Accessory
4-Point support structure
New Cassette 4.5m
Wide Jet Vane Improved wide and narrow vane will provide comfortable temperature distribution without air flow dead zone.
• Air flow improvement
80mm Wider!!
567mm
NEW Current
487mm
Highlander Even air distribution
Temp. 27°C
15°C
Current
Air flow dead zone
Temp. 27°C
15°C
High Ceiling Mode High ceiling mode with phase-control algorithm is possible to apply as high as 3.6m of ceiling. Conventional
4 way CST
Tropical Multi V III Tropical Multi V Mini
Flexible Connection Flexible connection of remote controller
• Easy & solid attachment to the wall
Tropical Multi V Water II
- Group control : 1 remote controller to several indoor units - Second remote control : 2 remote controllers to 1 indoor unit
Multi V series Indoor unit
Application of Ceiling Concealed Duct It is possible to make each rooms cool & warm with installing a chamber and a spiral duct.
eco V
Max. 9 discharging
V-Net & Accessory
Linear E.S.P Control Air volume and sound are always kept as design regardless of E.S.P change using this technology , you can • Optimize duct work Installation • Keep capacity & sound level as desired • Simplify model numbers The phase control motor technology offers money saving benefit to the installer. *E.S.P is easily controlled by remote controller
Compact Size The indoor unit with slim and compact size has reduced the restriction which enables successful installation in various spaces.
6.0 ~ 7.2 kW 8.3 ~ 11.0 kW conventional LG 218mm
288mm
204mm 246mm
Tropical Multi V III Tropical Multi V Mini
One Touch Type Panel It provides easy installation with a one-touch detachable panel.
Tropical Multi V Water II
Convenient Installation • Coner detachable design
Refrigerant piping check
Hanger adjust
Drain leakage check
Drain leakage check
Multi V series Indoor unit
Easy installation with corner detachable decoration panel.
Hanger adjust
Hanger adjust eco V V-Net & Accessory
Easy Drain Installation It reduces the installation time by over 40% with elbow-less drain hose.
Drain hose
Drain pump
Midget drain pump covers maximum 800mm high, featuring easy piping installation. * Accessory (Drain hose) PHDHA05T – 500mm 30EA PHDHA07T - 700mm 30EA
PHDHA05B – 500mm 5EA PHDHA07B – 700mm 5EA
3Way Flexible Installation All sides (front, back, floor) are possible to install and connect to the outdoor unit.
Back
Side
Floor
Sliding Type Filter All sides (front, back, floor) are possible to install and connect to the outdoor unit. Anti-biotic filter
Sliding type
Easy cleaning
Tropical Multi V III Tropical Multi V Mini
Neo Plasma Air Purifying System Unique NEO Plasma air purifying system is equipped with 7 specialized filters in 5 separate stages to enhance its cleaning power. It reduces fine dust and mold, unpleasant odors and cigarette smoke as air passes through each filter.
Clean Air
03 Bio Fusion Filter
The antibacterial pre-filter primarily reduces large dust, mold and quilt dust.
Bio fusion filters allow their Bio enzymes to directly penetrate through cell walls of some bacteria and allergen to decompose its cell nuclei.
02 Triple Filter
04 Plasma Filter
The triple filter consists of three specialized filters to reduce the symptoms associated with various organic compounds including formaldehyde. It also has the ability to reduce unpleasant odors creating a more comfortable environment.
The PLASMA Air Purifying System developed uniquely and not only reduces microscopic contaminants and dust, but also reduces house mites, pollen, and pet fur to reduce allergy and asthma symptoms.
eco V
01 Pre Filter
Multi V series Indoor unit
Odor Free! Dust Free! Allergy Free!
Tropical Multi V Water II
Polluted Air
V-Net & Accessory
Digital Air Flow Control The air flow can be controlled to ensure maximum comfort and convenience.
Normal
fast & even widely
Jet cool
speedy & powerful
Sleep mode
indirectly & softly
Swirl Swing Swirl swing distributes air evenly throughout the room to ensure a more comfortable conditioned environment by adjusting the movement of the vane.
• Comparison of temperatures
Swirl swing (plaesant air)
Normal air flow
Vertical Temp. differences
Horizontal Temp. differences
Healthy Dehumidification Dehumidification mode reduces uncomfortable humidity from the room without over cooling.
Indoor Temperature Distribution Chart Healthy By increasing the vane angle, a better approach of the actual temperature is possible to prevent over cooling.
Conventional Since the surrounding temperature is measured after the air from the unit is widely distributed, accurate approach of the air is not possible.
Tropical Multi V III Tropical Multi V Mini
Comfort Air Flow
Cooling
Heating (Nomal)
Heating (Floor Heating Mode)
1st Advanced pre filter : The antibacterial pre-filter primarily reduces large dust, mould and quilt dust.
3rd Plazma Inon Generator
V-Net & Accessory
3rd Plazma Inon Generator : The sterilized ion generating system, Ion Generator, emits around 1.2 million ions, and catches hazardous substances floating in the air, therefore proactively looking for and catching germs.
2nd Allergy Filter
eco V
2nd Allergy Filter : Filter consists of enzyme that breaks down allergen, apatite, andorganic/inorganic binder that attaches the enzyme to the filter. When the air passes the filter, allergen clings to the filter and like tiny pairs of scissors the enzymes cut allergen's protein to deactivate the allergen.
1st Advanced pre filter
Multi V series Indoor unit
Healthy Air (3 stage air filter system)
Tropical Multi V Water II
Different air flow of cooling & heating For cooling, the vane is adjusted upwards to let the cold air travel up. As for heating, the vane sends the heated air downwards to balance room temperature specially for floor.
Auto Clean Auto clean helps to remove odor and save clean-up time. After using airconditioner, “Auto clean” makes the inner part of Air conditioner dry for 30 min. It removes mositure and mold so you can enjoy odor-free air and save time to clean up.
Auto Clean
Conventional
1 STEP Dries the evaporator with gentle low noise air from the fan by removing any remaining moisture. Pressing the Auto Clean button will activate the automatic cleaning function after the cooling operation.
2 STEP Removes moulds through the neo plasma system. Only the fan will operate to dry the inner part of the air conditioner in just 30 minutes.
Air Flow Direction Control ow control Adjust the horizontal airflow direction by manually moving the horizontal airflow direction vane by hand. ow The airflow direction can be adjusted as desired by using the remote controller.
• Horizontal airflow control
• Vertical airflow control
Tropical Multi V III Tropical Multi V Mini
Weekly Program The operator can set an on/off reservation of the air conditioner for a period of one week. SUNDAY MONDAY
• On/Off • Test run mode • Self-diagnosis • 3-step fan speed selection • Operation indication • Room temperature
TUESDAY WEDNESDAY THURSDAY FRIDAY
Tropical Multi V Water II
LCD Wired Remote Controller
SATURDAY
Multi V series Indoor unit
Accessory Wired Remote Controller
Deluxe Type
Standard Type
Standard Type
Standard Type
Simple Type
Simple Type for Hotel
PQRCUDS0-X
PQRCVSL0-X
PQRCVSL0QW-X
PZRCUSB0-X
PQRCVCL0QW-X PQRCVCL0Q-X
PQRCHCA0QW-X PQRCHCA0Q-X
eco V
Wireless remote controller
V-Net & Accessory
PQWRH(C)DF0-X
WALL MOUNTED BTNI07GGSEP-X BTNI09GGSEP-X BTNI12GGSEP-X BTNI15GGSEP-X BTNI18GS5P-X BTNI24GS5P-X
Specifications Model Capacity
Unit Cooling
kW Btu/h
Heating
kW Btu/h
BTNI07GGSEP-X
BTNI09GGSEP-X
BTNI12GGSEP-X
BTNI15GGSEP-X
BTNI18GS5P-X
2.2
2.8
3.6
4.5
5.6
7.1
7,500
9,600
12,300
15,400
19,100
24,200
BTNI24GS5P-X
2.5
3.2
4.0
5.0
6.3
8.0
8,500
10,900
13,600
17,100
21,500
27,300 40
Power
Cooling
W
40
40
40
40
40
Input
Heating
W
40
40
40
40
40
40
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
895x165x282
895x165x282
895x165x282
895x165x282
1090x178x300
1090x178x300
9
9
9
9
12
12
dBA±3
37 / 33 / 23
39 / 35 / 25
41 / 36 / 27
42 / 36 / 27
44 / 40 / 36
46 / 41 / 38
CMM
5.6 / 5 / 4.6
7 / 6.5 / 6
9.5 / 9 / 8.5
10.5 / 9 / 8.5
12 / 10.5 / 9
14 / 13 / 10
Power Supply
Ø, V, Hz
Dimensions(WxDxH)
mm
Weight
kg
Noise level Air flow rate
H/M/L
Neo Plasma air purifying filter Piping
Liquid
mm(inch)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø9.52(3/8)
Connection
Gas
mm(inch)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø15.88(5/8)
20/16
20/16
20/16
20/16
20/16
20/16
BTNI15GGSEP-X
BTNI18GS5P-X
BTNI24GS5P-X
Drain(OD/ID)
mm
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
* Accessories BTNI07GGSEP-X
Model Dry Contact
Without case(1 contact point)
BTNI09GGSEP-X
BTNI12GGSEP-X
PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC
4 WAY CASSETTE (570*570) BTNI05GTRP-X BTNI07GTRP-X BTNI09GTRP-X BTNI12GTRP-X BTNI15GTQC-X BTNI18GTQC-X
Specifications Model Capacity
Unit Cooling
kW Btu/h
Heating
kW Btu/h
BTNI05GTRP-X
BTNI07GTRP-X
BTNI09GTRP-X
BTNI12GTRP-X
BTNI15GTQC-X
1.6
2.2
2.8
3.6
4.5
5.6
5,500
7,500
9,600
12,300
15,400
19,100
BTNI18GTQC-X
1.8
2.5
3.2
4.0
5.0
6.3
6,100
8,500
10,900
13,600
17,100
21,500 30
Power
Cooling
W
30
30
30
30
30
Input
Heating
W
30
30
30
30
30
30
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
Power Supply
Ø, V, Hz
Dimensions
Body
mm
570x570x214
570x570x214
570x570x214
570x570x214
570x570x256
570x570x256
(WxDxH)
Front panel
mm
700x700x30
700x700x30
700x700x30
700x700x30
700x700x30
700x700x30
Weight
Body
kg
13.1
13.1
14.2
14.2
15.5
15.5
Front panel
3.2
3.2
3.2
3.2
3.2
3.2
Morning Fog
Morning Fog
Morning Fog
Morning Fog
Morning Fog
Morning Fog
dBA±3
29 / 27 / 26
29 / 27 / 26
30 / 29 / 27
32 / 30 / 27
36 / 34 / 32
37 / 35 / 34
CMM
7.5 / 7 / 6.6
7.5 / 7 / 6.6
8 / 7.5 / 7.1
8.7 / 8 / 7
11 / 10 / 9.3
11.2 / 11 / 10
Panel Color Noise level Air flow rate
H/M/L
Neo Plasma air purifying filter Drain Pump Piping
Liquid
mm(inch)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Connection
Gas
mm(inch)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
32/25
32/25
32/25
32/25
32/25
32/25
BTNI15GTQC-X
BTNI18GTQC-X
Drain(OD/ID)
mm
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
* Accessories BTNI05GTRP-X
Model Dry Contact
Front Panel
Without case(1 contact point)
BTNI07GTRP-X
BTNI09GTRP-X
BTNI12GTRP-X
PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC PT-UQC
Tropical Multi V Mini
BTNI24GTPP-X BTNI28GTPP-X BTNI36GTNP-X BTNI42GTMP-X BTNI48GTMP-X
Capacity
Unit Cooling
kW Btu/h
Heating
kW Btu/h
BTNI24GTPP-X
BTNI28GTPP-X
BTNI36GTNP-X
BTNI42GTMP-X
7.1
8.2
10.6
12.3
14.1
24,200
28,000
36,200
42,000
48,100
BTNI48GTMP-X
8.0
9.2
11.9
13.8
15.9
27,300
31,500
40,600
43,800
51,200 144
Cooling
W
33
33
144
144
Input
Heating
W
33
33
144
144
144
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
Power Supply
Ø, V, Hz
Dimensions
Body
mm
840x840x204
840x840x204
840x840x246
840x840x288
840x840x288
(WxDxH)
Front panel
mm
950x950x25
950x950x25
950x950x25
950x950x25
950x950x25
Weight
Body
kg
20.8
20.8
23.5
25.6
25.6
Front panel
5.6
5.6
5.6
5.6
5.6
Morning Fog
Morning Fog
Morning Fog
Morning Fog
Morning Fog
dBA±3
36 / 34 / 31
39 / 35 / 33
43 / 40 / 37
44 / 41 / 38
46 / 43 / 41
CMM
17 / 15 / 13
19 / 16 / 14
25 / 21 / 19
30 / 27 / 24
31 / 29 / 27
Panel Color Noise level Air flow rate
H/M/L
Neo Plasma air purifying filter
Multi V series Indoor unit
Power
Tropical Multi V Water II
Specifications Model
Tropical Multi V III
4 WAY CASSETTE (840*840)
Drain Pump Piping
Liquid
mm(inch)
Ø9.52(3/8)
Ø9.52(3/8)
Ø9.52(3/8)
Ø9.52(3/8)
Ø9.52(3/8)
Connection
Gas
mm(inch)
Ø15.88(5/8)
Ø15.88(5/8)
Ø15.88(5/8)
Ø15.88(5/8)
Ø15.88(5/8)
32/25
32/25
32/25
32/25
32/25
BTNI28GTPP-X
BTNI36GTNP-X
BTNI42GTMP-X
BTNI48GTMP-X
Drain(OD/ID)
mm
eco V
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
* Accessories Dry Contact
Without case(1 contact point)
PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC
Front Panel
PT-UMC
Auto Elevation Grille
PTEGM0
Ventilation Kit
PTVK410 / PTVK420 / PTVK 430
V-Net & Accessory
BTNI24GTPP-X
Model
2 WAY CASSETTE
BTNI18GTLP-X BTNI24GTLP-X
Specifications Model Capacity
Unit Cooling
BTNI18GTLP-X kW Btu/h
Heating
kW Btu/h
BTNI24GTLP-X
5.6
7.1
19,100
24,200
6.3
8.0
21,500
27,300 70
Power
Cooling
W
70
Input
Heating
W
70
70
1, 220~240, 50
1, 220~240, 50
Power Supply
Ø, V, Hz
Dimensions
Body
mm
830x550x225
830x550x225
(WxDxH)
Front panel
mm
1,050x640x28.5
1,050x640x28.5
Weight
Body
kg
22
22
Front panel
4.5
4.5
Morning Fog
Morning Fog
dBA±3
40 / 36 / 32
42 / 38 / 34
CMM
13 / 12 / 10
17 / 15 / 13
Panel Color Noise level Air flow rate
H/M/L
Neo Plasma air purifying filter Drain Pump Piping
Liquid
mm(inch)
Ø6.35(1/4)
Ø9.52(3/8)
Connection
Gas
mm(inch)
Ø12.7(1/2)
Ø15.88(5/8)
32/25
32/25
Drain(OD/ID)
mm
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
* Accessories BTNI18GTLP-X
Model Dry Contact
Front Panel
Without case(1 contact point)
BTNI24GTLP-X PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC PT-HLC
BTNI07GTUP-X BTNI09GTUP-X BTNI12GTUP-X BTNI18GTTP-X BTNI24GTTP-X
Grill Type
Tropical Multi V Mini
Moving Panel Type
Capacity
Unit Cooling
kW Btu/h
Heating
kW Btu/h
BTNI07GTUP-X
BTNI09GTUP-X
BTNI12GTUP-X
BTNI18GTTP-X
2.2
2.8
3.6
5.6
7.1
7,500
9,600
12,300
19,100
24,200
BTNI24GTTP-X
2.5
3.2
4.0
6.3
7.1
8,500
10,900
13,600
21,500
24,200 70
Cooling
W
40
40
40
70
Input
Heating
W
40
40
40
70
70
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
Power Supply
Ø, V, Hz
Dimensions
Body
mm
860x450x132
860x450x132
860x450x132
1,180x450x132
1,180x450x132
(WxDxH)
Front panel
mm
1,100x500x34
1,100x500x34
1,100x500x34
1,420x500x34
1,420x500x34
Weight
Body
14.7
14.7
14.7
18.7
18.7
5.3/4.4
5.3/4.4
5.3/4.4
6.5/5.5
6.5/5.5
kg
Front panel(Panel/Grille) Panel Color Noise level Air flow rate
dBA±3 H/M/L
CMM
White
White
White
White
White
32 / 29 / 25
35 / 34 / 32
38 / 35 / 32
40 / 37 / 35
43 / 40 / 36
8.2 / 7.3 / 6.4
9.2 / 8.6 / 8.2
10 / 9.2 / 8.2
14.6 / 12.1 / 10.9
14.6 / 13.3 / 11.5
Neo Plasma air purifying filter
Multi V series Indoor unit
Power
Tropical Multi V Water II
Specifications Model
Tropical Multi V III
1 WAY CASSETTE
Drain Pump Piping
Liquid
mm(inch)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø9.52(3/8)
Connection
Gas
mm(inch)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø15.88(5/8)
32/25
32/25
32/25
32/25
32/25
BTNI09GTUP-X
BTNI12GTUP-X
BTNI18GTTP-X
Drain(OD/ID)
mm
eco V
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
* Accessories Dry Contact
Front Panel
BTNI24GTTP-X
PQDSA
PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC
PQDSBC
Grill Type
PT-UUC
PT-UUC
Moving Panel Type
PT-UUD
PT-UUD
Without case(1 contact point)
V-Net & Accessory
BTNI07GTUP-X
Model
LOW STATIC DUCT BTNI07GB1S-X BTNI09GB1S-X BTNI12GB1S-X BTNI15GB1S-X BTNI18GB2S-X BTNI24GB2S-X
Specifications Model Capacity
Unit Cooling
kW Btu/h
Heating
kW Btu/h
BTNI07GB1S-X
BTNI09GB1S-X
BTNI12GB1S-X
BTNI15GB1S-X
BTNI18GB2S-X
2.2
2.8
3.6
4.5
5.6
7.1
7,500
9,600
12,300
15,400
19,100
24,200
BTNI24GB2S-X
2.5
3.2
4.0
5.0
6.3
8.0
8,500
10,900
13,600
17,100
21,500
27,300 80
Power
Cooling
W
30
30
30
30
80
Input
Heating
W
30
30
30
30
80
80
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
820x575x190
820x575x190
820x575x190
820x575x190
1,100x575x190
1,100x575x190
21
21
21
21
26
26
29 / 26 / 24
31 / 29 / 26
33 / 30 / 29
34 / 33 / 31
40 / 37 / 34
43 / 40 / 37
Power Supply
Ø, V, Hz
Dimensions(WxDxH)
mm
Weight
kg
Noise level
dBA±3
E.S.P range Air flow rate
H/M/L
mmAq
0~4
0~4
0~4
0~4
0~4
0~4
CMM
8.5 / 7.5 / 6.5
9.5 / 8.5 / 7.5
10.5 / 9.5 / 8.5
11.5 / 10.5 / 9.5
16 / 14 / 12
19 / 17 / 15
-
-
-
-
-
-
Liquid
mm(inch)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø9.52(3/8)
Gas
mm(inch)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø15.88(5/8)
32/25.4
32/25.4
32/25.4
32/25.4
32/25.4
32/25.4
BTNI15GB1S-X
BTNI18GB2S-X
BTNI24GB2S-X
Neo Plasma air purifying filter Piping Connection
Drain(OD/ID)
mm
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
* Accessories BTNI07GB1S-X
Model Dry Contact
Without case(1 contact point)
BTNI09GB1S-X
BTNI12GB1S-X
PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC
HIGH STATIC DUCT BTNI07GBHS-X BTNI09GBHS-X BTNI12GBHS-X BTNI15GBHS-X BTNI18GBHS-X BTNI24GBHS-X
Specifications Model Capacity
Unit Cooling
kW Btu/h
Heating
kW Btu/h
BTNI07GBHS-X
BTNI09GBHS-X
BTNI12GBHS-X
BTNI15GBHS-X
BTNI18GBHS-X
2.2
2.8
3.6
4.5
5.6
7.1
7,500
9,600
12,300
15,400
19,100
24,200
BTNI24GBHS-X
2.5
3.2
4.0
5.0
6.3
8.0
8,500
10,900
13,600
17,100
21,500
27,300 150
Power
Cooling
W
150
150
150
150
150
Input
Heating
W
150
150
150
150
150
150
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
882x450x260
882x450x260
882x450x260
882x450x260
882x450x260
882x450x260
26
26
26
26
26.5
26.5
34 / 33 / 32
35 / 34 / 33
37 / 35 / 34
39 / 38 / 37
42.5 / 41 / 37
45 / 43 / 41
8.5 / 7.5 / 6
10 / 8.5 / 7.5
12 / 10 / 8.5
13.5 / 12 / 8.5
15.5 / 13.5 / 12.4
18.3 / 16.9 / 15.5
-
-
-
-
-
-
Power Supply
Ø, V, Hz
Dimensions(WxDxH)
mm
Weight
kg
Noise level
dBA±3
E.S.P range Air flow rate
mmAq H/M/L
CMM
Neo Plasma air purifying filter Piping Connection
Liquid
mm(inch)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø9.52(3/8)
Gas
mm(inch)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø15.88(5/8)
32/25
32/25
32/25
32/25
32/25
32/25
BTNI15GBHS-X
BTNI18GBHS-X
BTNI24GBHS-X
Drain(OD/ID)
mm
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
* Accessories BTNI07GBHS-X
Model Dry Contact
Without case(1 contact point)
BTNI09GBHS-X
BTNI12GBHS-X
PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC
Tropical Multi V Mini
BTNI28GBGS-X BTNI36GBGS-X BTNI42GBGS-X BTNI48GBRS-X URNU76GB8S-X URNU96GB8S-X
Capacity
Unit Cooling
kW Btu/h
Heating
kW Btu/h
BTNI28GBGS-X
BTNI36GBGS-X
BTNI42GBGS-X
BTNI48GBRS-X
URNU76GB8S-X
8.2
10.6
12.3
14.1
22.4
28.0
28,000
36,200
42,000
48,100
76,400
95,900
URNU96GB8S-X
9.2
11.9
13.8
15.9
25.2
31.5
31,500
40,600
43,800
51,200
86,000
107,500 800
Cooling
W
450
450
450
450
800
Input
Heating
W
450
450
450
450
800
800
Ø, V, Hz
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
mm
1,182x450x298
1,182x450x298
1,182x450x298
1,230x590x380
1,562x688x460
1,562x688x460
38
38
38
53
87
87
44 / 42 / 40
46 / 44 / 42
48 / 46 / 45
45 / 43 / 41
50 / 48 / 48
52 / 50 / 50 76 / 64 / 64
Power Supply Dimensions(WxDxH) Weight
kg
Noise level
dBA±3
E.S.P range Air flow rate
H/M/L
mmAq
6~16
6~14
6~12
7~20
CMM
25.9 / 24.1 / 21.8
32.3 / 29 / 25.3
34.5 / 32.3 / 30.7
44.8 / 40.6 / 33.3
64 / 50 / 50
-
-
-
-
-
-
Neo Plasma air purifying filter Piping Connection
Liquid
mm(inch)
Ø9.52(3/8)
Ø9.52(3/8)
Ø9.52(3/8)
Ø9.52(3/8)
Ø9.52(3/8)
Ø9.52(3/8)
Gas
mm(inch)
Ø15.88(5/8)
Ø15.88(5/8)
Ø15.88(5/8)
Ø15.88(5/8)
Ø19.05(3/4)
Ø22.2(7/8)
32/25
32/25
32/25
32/25
32/25
32/25
BTNI48GBRS-X
URNU76GB8S-X
URNU96GB8S-X
Drain(OD/ID)
mm
eco V
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
Multi V series Indoor unit
Power
Tropical Multi V Water II
Specifications Model
Tropical Multi V III
HIGH STATIC DUCT
* Accessories Dry Contact
Without case(1 contact point)
BTNI36GBGS-X
BTNI42GBGS-X
PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC
V-Net & Accessory
BTNI28GBGS-X
Model
CEILING & FLOOR
BTNI09GVES-X BTNI12GVES-X
Specifications Model Capacity
Unit Cooling
BTNI09GVES-X kW Btu/h
Heating
kW Btu/h
BTNI12GVES-X
2.8
3.6
9,600
12,300
3.2
4.0
10,900
13,600 30
Power
Cooling
W
30
Input
Heating
W
30
30
1, 220~240, 50
1, 220~240, 50
900x200x490
900x200x490
Power Supply
Ø, V, Hz
Dimensions(WxDxH)
mm
13.7
13.7
dBA±3
36 / 32 / 28
38 / 36 / 30
CMM
7.6 / 6.9 / 6.2
9.2 / 7.6 / 6.9
Weight
kg
Noise level Air flow rate
H/M/L
Plasma air purifying filter Piping Connection
-
-
Liquid
mm(inch)
Ø6.35(1/4)
Ø6.35(1/4)
Gas
mm(inch)
Ø12.7(1/2)
Ø12.7(1/2)
20/16
20/16
Drain(OD/ID)
mm
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
* Accessories BTNI09GVES-X
Model Dry Contact
Without case(1 contact point)
BTNI12GVES-X PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC
Tropical Multi V Mini
URNU18GVJS-X URNU24GVJS-X URNU48GVLS-X
Model
Unit Cooling
kW Btu/h
Heating
kW Btu/h
URNU18GVJS-X
URNU24GVJS-X
5.6
7.1
14.1
19,100
24,200
48100
URNU48GVLS-X
6.3
8.0
15.9
21,500
27,300
51200 63
Cooling
W
63
63
Input
Heating
W
63
63
63
1, 220~240, 50
1, 220~240, 50
1, 220 ~ 240, 50
950x220x650
950x220x650
1750x650x220
24.6
24.6
45
dBA±3
42 / 40 / 37
43 / 41 / 39
49/48/47
CMM
16 / 14 / 12
18 / 16 / 14
35/32/30
-
-
-
Power Supply
Ø, V, Hz
Dimensions(WxDxH)
mm
Weight
kg
Noise level Air flow rate
H/M/L
Plasma air purifying filter Piping Connection
Liquid
mm(inch)
Ø6.35(1/4)
Ø9.52(3/8)
Ø9.52(3/8)
Gas
mm(inch)
Ø12.7(1/2)
Ø15.88(5/8)
Ø15.88(5/8)
20/16
20/16
16(5/8)
BTNI24GVJS-X
URNU48GVLS-X
Drain(OD/ID)
mm
eco V
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
Multi V series Indoor unit
Power
Tropical Multi V Water II
Specifications Capacity
Tropical Multi V III
CEILING SUSPENDED
* Accessories Dry Contact
Without case(1 contact point)
PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC
V-Net & Accessory
BTNI18GVJS-X
Model
FLOOR STANDING WITH CASE BTNI07GCES-X BTNI09GCES-X BTNI12GCES-X BTNI15GCES-X BTNI18GCFS-X BTNI24GCFS-X
Specifications Model Capacity
Unit Cooling
kW Btu/h
Heating
kW Btu/h
BTNI07GCES-X
BTNI09GCES-X
BTNI12GCES-X
BTNI15GCES-X
BTNI18GCFS-X
2.2
2.8
3.6
4.5
5.6
7.1
7,500
9,600
12,300
15,400
19,100
24,200
BTNI24GCFS-X
2.5
3.2
4.0
5.0
6.3
8.0
8,500
10,900
13,600
17,100
21,500
27,300 80
Power
Cooling
W
30
30
30
30
80
Input
Heating
W
30
30
30
30
80
80
Ø, V, Hz
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
mm
1,067x203x635
1,067x203x635
1,067x203x635
1,067x203x635
1,345x203x635
1,345x203x635
27
27
27
27
34
34
dBA±3
35 / 33 / 31
36 / 34 / 32
37 / 35 / 33
38 / 37 / 25
40 / 37 / 34
43 / 40 / 37
CMM
8.5 / 7.5 / 6.5
9.5 / 8.5 / 7.5
10.5 / 9.5 / 8.5
11.5 / 10 / 9.5
16 / 14 / 12
18 / 16 / 14
-
-
-
-
-
-
Power Supply Dimensions(WxDxH) Weight
kg
Noise level Air flow rate
H/M/L
Plasma air purifying filter Piping Connection
Liquid
mm(inch)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø9.52(3/8)
Gas
mm(inch)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø15.88(5/8)
12
12
12
12
12
12
BTNI15GCES-X
BTNI18GCFS-X
BTNI24GCFS-X
Drain(OD/ID)
mm
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
* Accessories BTNI07GCES-X
Model Dry Contact
Without case(1 contact point)
BTNI09GCES-X
BTNI12GCES-X
PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC
Tropical Multi V Mini
BTNI07GCEUS-X BTNI09GCEUS-X BTNI12GCEUS-X BTNI15GCEUS-X BTNI18GCFUS-X BTNI24GCFUS-X
Model
Unit Cooling
kW Btu/h
Heating
kW Btu/h
BTNI07GCEUS-X
BTNI09GCEUS-X
BTNI12GCEUS-X
BTNI15GCEUS-X
BTNI18GCFUS-X
2.2
2.8
3.6
4.5
5.6
BTNI24GCFUS-X 7.1
7,500
9,600
12,300
15,400
19,100
24,200
2.5
3.2
4.0
5.0
6.3
8.0
8,500
10,900
13,600
17,100
21,500
27,300 80
Cooling
W
30
30
30
30
80
Input
Heating
W
30
30
30
30
80
80
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
1, 220~240, 50
978x190x639
978x190x639
978x190x639
978x190x639
1,256x190x639
1,256x190x639
20
20
20
20
27
27
dBA±3
35 / 33 / 31
36 / 34 / 32
37 / 35 / 33
38 / 37 / 35
40 / 37 / 34
43 / 40 / 37
CMM
8.5 / 7.5 / 6.5
9.5 / 8.5 / 7.5
10.5 / 9.5 / 8.5
11.5 / 10 / 9.5
16 / 14 / 12
18 / 16 / 14
-
-
-
-
-
-
Power Supply
Ø, V, Hz
Dimensions(WxDxH)
mm
Weight
kg
Noise level Air flow rate
H/M/L
Plasma air purifying filter Piping Connection
Liquid
mm(inch)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø9.52(3/8)
Gas
mm(inch)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø15.88(5/8)
12
12
12
12
12
12
BTNI15GCEUS-X
BTNI18GCFUS-X
BTNI24GCFUS-X
Drain(OD/ID)
mm
eco V
Note : 1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero 2. Due to our policy of innovation some specifications may be changed without notification
Multi V series Indoor unit
Power
Tropical Multi V Water II
Specifications Capacity
Tropical Multi V III
FLOOR STANDING WITHOUT CASE
* Accessories Dry Contact
BTNI07GCEUS-X
Without case(1 contact point)
BTNI09GCEUS-X
BTNI12GCEUS-X
PQDSA
With case(1 contact point)
PQDSB/ PQDSB1
With case(2 contact point)
PQDSBC
V-Net & Accessory
Model
Tropical Multi V III
Tropical Multi V Mini
Tropical Multi V Water II
Multi V series Indoor unit
eco V
V-Net & Accessory