Beko High Ambient (Tropical) VRS/VRF Catalogue

Page 1


High Performance

BEKO VRS Systems


Enjoy a Clean & Comfortable life with Xtreme VRS 3




Contents

Outdoor Unit Xtreme VRS 3

10

Xtreme VRS MINI

28

VRS WATERACE

32

(Heat Pump, Heat Recovery)

Indoor Unit Wall Mounted

60

ART COOL

62

Ceiling Cassette

64

Ceiling Duct

68

Ceiling & Floor / Suspended

72 73

Floor Standing

74

VRS 3 Vent VRS 3 Vent

80

VRS 3 Vent DX

84

Fresh Air Intake Unit

85

AHU Kit

86

Automation & Accessory Remote Controller

96

Central Controller

100

Accessory

104


BEKO XTREME VRS 3 SERIES

2012 OUTDOOR UNIT LINE-UP | HP |

4

6

8

10

22

24

26

28

40

42

44

46

| HP |

4

5

6

7

| HP |

10

20

30

40


12

14

16

gy

18

20

g

30

32

34

36

38

48

50

60

70

80

8

9

10

11

12

50

60

70

80

90


BEKO XTREME VRS 3 SERIES

Ceiling Cassette

SRAC

2012 OUTDOOR UNIT LINE-UP kW

1.5

2.2

2.8

3.6

Btu / h

5k

7k

9k

12k

Wall Mounted 4way Cassette (570*570) 4way Cassette (840*840) 2way Cassette

Low Static

High Static

FAU

VRS 3 Vent

Floor Standing

Ceiling & Floor / Ceiling Suspended

Ceiling Concealed Duct

1way Cassette

With Case Without Case Vent Vent DX Fresh Air Intake Unit


4.5

5.6

7.1

8.2

10.6

12.3

14.1

22.4

28.0

15k

18k

24k

28k

36k

42k

48k

76k

96k

4.71, 7.46, 9.12 kW

14.1, 22.4, 28 kW


Enjoy a Clean & Comfortable life with Xtreme VRS 3


Tropical Multi V III

VRS 3 Inverter units composed of serially arranged refrigerant pipes connected

saving, simple and easy installation, and connection to different types of indoor units, making it easy to design and install.

Tropical Multi V Mini

to a single outdoor unit are an efficient system that offers outstanding energy

Tropical Multi V Water II Multi V series Indoor unit eco V V-Net & Accessory


The world’s best cooling COP • High efficiency BLDC V-scroll inverter compressor • High efficiency BLDC inverter fan motor

COP Comparison (Base on 12HP) MULTIACE VRS 3

• High air volume fan

11% UP

• Optimal heat exchanger distribution

4.12

3.7 Coefficient of Performance (COP) =

Cooling capability Energy consumption

Therefore, the higher the COP of a product, the higher its cooling and heating capability and the lower its energy consumption.

Cooling

Maximum single unit capacity of 16HP VRS 3 offers world’s largest capacity of 16HP for a single unit. The two basic modules, small unit (up to 10HP), and large unit (up to 16HP), can be combined freely. Since one outdoor unit is enough to heat and cool a large area, the design of the VRS 3 is simple and installation costs are kept to a minimum.

16HP Single Unit !!

Small 8~10HP

Large 12~16HP


Pursuing the market needs of high energy efficiency and environmental friendliness.

Tropical Multi V Mini

Technical innovation for high COP

Tropical Multi V III

Outdoor Unit

As VRS 3 has high efficiency parts, advanced interver control technology and optimal cycle control technology, the system’s unified performance has been improved. Based on these advanced technologies, the product provides customers with value through high efficiency and energy savings.

1

BLDC v-scroll inverter compressor

2

Sine wave inverter control

3

Cyclone sub-cooling circuit

4

Newly designed propeller fan

5

BLDC v-scroll inverter fan motor

6

New refrigerant distributor for the heat exchanger

7

Wide louver fins for the heat exchanger

5

3 2

Improved the energy efficiency by 11%, compared with the AC inverter compressor, by using the high efficiency BLDC inverter compressor.

Tropical Multi V Water II

4

Improved the efficiency of the compressor motor by using the sine wave DC inverter control technology.

6 7 1

Improved the cooling capability by using a cyclone sub-cooling circuit.

Achieved optimal heat exchange by using high air volume and low noise fan.

eco V

Improved efficiency by using high efficiency BLDC inverter motor, compared with the AC motor.

Improved heat exchange performance and efficiency by reducing greatly the heat exchanger’s temperature deviation from 5ºC to 1 degree by applying an optimal distributor design to the heat exchanger.

V-Net & Accessory

Improved efficiency by using wide louver fins with an increased heating area.


Extended piping length and elevation Because of the product’s use of inverter control technology and sub-cooling control circuit technology, it is possible to design a system with the world’s longest piping length and world’s highest elevation difference. With this product, since a cooling and heating system can be designed more flexibly in a high-rise building or complex facilities building, the designer’s working time is reduced, thus allowing a more efficient design.

Total piping length Actual longest piping length (Equivalent) Longest piping length after 1st branch (Conditional application) Level difference between ODU~IDU Level difference between IDU~IDU Level difference between ODU~ODU

1000m 200m (225m) 40m (90m) 110m 15m 5m

Space utilization by smaller size The product size is reduced by up to 50% compared to the existing products, reducing the required installation space greatly. This gives you more free space and thus allows for easier HVAC design.

MULTIACE

VRS 3 XTREME

16HP 10HP

16HP 20HP

25%

50%

Reduction

Reduction

MULTIACE

VRS IIl


Tropical Multi V III

Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.

Tropical Multi V Mini

Eco-friendly design We not only produce high efficiency products that have excellent energy-saving capability, but we also develop eco-friendly products with green technology that protects the earth and the environment. With these products, we are leading the world in low carbon and green development.

Tropical Multi V Water II

R410A Refrigerant

Multi V series Indoor unit

No refrigerant leakage design and production

Refrigerant recovery and reuse eco V

Refrigerant recovery

Auto leakage detection V-Net & Accessory


Maximum combination capacity of 48HP with a single pipe A combination of up to 48HP can be made using 16HP units. This makes it possible to design a HVAC system that fits into an extensive space. The usual major problems in design, such as installation space for outdoor units, pipe shaft space and piping line, are no longer an issue.

Outdoor unit combination of up to 48HP

Installation space saving - Optimal space utilization

Single pipe - Easy to design. - Cooling and heating for an extensive space - Installation cost savings

When designing a HVAC system with a total capacity of 240HP, our 48HP VRS 3 combination give you the following benefits, compared with conventional 36HP combination models

Comparison of outdoor unit installation space Conventional

• Reduces the installation space by 50%. • A large capacity design reduces the time spent on designing the HVAC system, and also reduces the construction costs.

VRS 3


Tropical Multi V III

Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.

To provide our customers with the world’s best cooling and heating performance at a minimum size, and as well as a pleasant environment created with quiet operation, VRS 3 uses various low noise technologies. It has minimized operation noise by using a compressor with BLDC motors, low noise fan motors, new soundproof technology, outdoor fans, and a newly developed shroud shape.

Multi V series Indoor unit

New designs for low operation noise

54ºC

Tropical Multi V Water II

The product has more extended continuous cooling operation range and operable range than the existing products, enabling more extensive operation. It has extended the operation range by using more enhanced inverter compressor and control technology.

Tropical Multi V Mini

Wide operating range / Cooling at 54ºC

eco V V-Net & Accessory


High static pressure fan Since the product uses a more powerful high static pressure fan, the outdoor unit can be installed not only on the roof of a building but also inside the building by using an air duct. Because of the high static pressure fans and the BLDC fan motors, a sufficient air volume can be acquired for heat exchange and no re-circulation of the discharged air currents occurs. Depending on the building structure, you can reduce the piping length by installing the outdoor unit in the machine room.

erent building structures

No stacking of high temperature air occurs due to powerful discharge of air currents even within a highrise building

Conventional model

VRS lll


Tropical Multi V III

Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.

Tropical Multi V Mini

Improved corrosion resistance with Goldfin™ Fin layer

Salt Spray Test for 15 Days

Tropical Multi V Water II

The patented chloride-induced corrosion resistant Goldfin has low corrosion and erosion rates and high hydrophilicity. Its performance will not be affected even in a humid area. (Please contact us regarding the chloride-induced corrosion resistance model.)

Flexible indoor unit combination

A combination with maximum 130% efficiency can be achieved only if the changes of the heating and cooling load and the product operation rate by time are considered

Connectable Indoor unit Capacity Up to Max 130%

Connectable Indoor unit Number Up to 64

Various Indoor units

13 types, 71 models

Multi V series Indoor unit

Since up to 64 indoor units can be connected and there are 13 types of 71 different indoor models that can be connected, a variety of designs tailored for individual construction usage can be made. Up to 130% efficiency can be achieved with different combinations.

Verify combination ratio at EPDB eco V V-Net & Accessory


Easy and safe transportation Fast and safe transportation by a forklift Forklift transportation hole Scratch prevention guide

Safety design for crane use

Transportation by a crane

Crane rope hole

Compact product design allowing transportation by an elevator Transportation by an elevator


Tropical Multi V III

Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.

Tropical Multi V Mini

Free 4-way piping connection 4-way piping design

Right Left Front

Tropical Multi V Water II

The piping lines for the outdoor unit can be connected in 4 ways (front/left/right/bottom piping), allowing various custom construction depending on the individual site. If the piping lines are installed on the floor (bottom piping), the product looks neat as they are hidden from view and, in addition, the piping lines also do not interfere with gas/liquid lines, making the installation work safe and convenient. Piping line tray work is not necessary depending on the individual site, which reduces additional working hours, and also makes maintenance easier when the product is installed in the machine room.

Bottom

Automatic test run reduce test run time by more than 60% compared to the test run in an existing product, and provides safe, reliable and convenient test run with various data backup functions. Since any general installation worker, not just a highly trained engineer, can perform a test run, the product also increases your installation competitiveness.

Multi V series Indoor unit

Intelligent simple test run

VRS 3

eco V

Conventional model

•Piping/ Communication lines •Entire room operation •Individual room operation •Reporting

•Piping/ Communication lines •Entire room operation •Individual room operation •Reporting

Automatic test run

V-Net & Accessory

•Piping/ Communication lines •Entire room operation •Individual room operation •Reporting


Automatic detection for incorrect connections In the existing products, if an installation engineer has connected a liquid line to a gas line by mistake, you have to take the trouble to check the piping line connections for the indoor units installed over the ceiling. However, VRS 3 automatically checks the connections of piping lines and communication lines with its FDD function and notifies the user if there is any problem. Usually, installation becomes more and more complex as the number of connected indoor units increases. But, with the automatic detection function of this product, installation is made easier and, when an indoor unit has a connection problem, you can take action quickly because the automatic detection function will inform you about that indoor unit.

Incorrect piping line connection (Liquid line + gas line)

Incorrect communication line connection

Real-time automatic fault prediction function With the existing products, their performance and reliability would be degraded due to a slight fault with a sensor or the EEV. However, this product allows you to check the current status for the sensors and the EEV, which are the major components for system control, through a through FDD test standard.

Outdoor unit

Indoor unit

Temperature sensor

11(16HP)

3

Pressure sensor

2

0

Based on one outdoor unit and one indoor unit, respectively

Sensor EEV


Tropical Multi V III

Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.

Tropical Multi V Mini

Pump down PUMP DOWN When an indoor unit malfunctions, this function collects the refrigerant remaining in the piping line or that unit to an outdoor unit.

Tropical Multi V Water II

When an indoor unit malfunctions, it needs to be replaced served before servicing this function automatically collects its refrigerant in outdoor unit running normally, making servicing very convenient and easy.

Multi V series Indoor unit

Automatic refrigerant charging function Calculates and automatically injects the optimal amount of refrigerant. Since the FDD algorithm calculates and automatically charges the correct amount of refrigerant without using an electronic scale, installation reliability is increased and product performance is guaranteed. Embedded with the FDD algorithm

eco V

Indicated by theLED indicator when fully charged

V-Net & Accessory


Automatic emergency back-up function When a compressor malfunctions, the other compressor that is operating normally in an outdoor unit can run automatically as a substitute, minimizing any inconvenience that may occur in an emergency situation.

Powerful Control Software This program allows you to monitor and control the operation status of the product. Since the program can be connected to either an outdoor unit or indoor unit, you can check the operation status of the product easily and conveniently any time and anywhere.

Software Cycle View

Cycle

Indoor unit control


Pursuing the market needs of high energy efficiency and environmental friendliness.

By using the core technologies, such as optimal and cutting-edge control on each part of the indoor and outdoor units, BLDC inverter compressors, and artificial intelligence, the product takes less than 10 minutes to reach the set temperature from the initial heating or cooling operation. In addition, it always creates a pleasant indoor atmosphere with no temperature variation by reducing the revolutions of the compressor and performing finer control when the temperature reaches close to the set temperature.

Multi V series Indoor unit

Fast and comfortable operation

Tropical Multi V Water II

By using the BLDC inverter compressor & fan control technology and the real-time outdoor temperature detection technology, the product is equipped with the night lownoise operation function. 8 stages of low-noise operation are possible to provide more quiet operation during the night.

Tropical Multi V Mini

Night silent operation

Tropical Multi V III

Outdoor Unit

eco V V-Net & Accessory


New & core technologies 1 BLDC inverter compressor Improved the energy efficiency by 11%, compared with the AC inverter compressor, by using the high efficiency BLDC inverter compressor.

2 New designed propeller fan (Super Aero fan)

OLD NEW

Provides low noise levels through pod-shaped design

Minimizes vortex resistance with a curved shape

Provides high air volume and high static pressure with the changed shape

Improved the energy efficiency by 11%, compared with the AC inverter compressor, by using the high efficiency BLDC inverter compressor.

2 1

3 New Sub-Cooling Circuit The sub-cooling circuit control acquires sub-cooled liquid refrigerant and thus improves the symptoms of oil recove r y de gradation and pe r for mance degradation that occur because a loss of system capability occurs throughout the piping lines. The sub-cooling circuit control is a core technology that enables the product to implement the world’s longest piping length and elevation difference technology. Sub-cooling circuit control: Extracts part of the refrigerant of the SC circuit equipped in the liquid line exit of an outdoor unit and expands that extracted refrigerant using the SC EEV to make low temperature refrigerant, and then performs heat exchange in the system using that low temperature to increase the sub-cooling rate of the system.

6

5 3

4 New BLDC inverter compressor We have developed a new compressor with better performance, higher efficiency, and a more enhanced reliability than the existing compressors. For the motor, which is the core of the compressor, the product uses a BLDC motor. The BLDC motor is a highly efficient motor, where strong ND magnetism inside the rotor produces magnetic torque and the metal part of the rotor produces reluctance torque to generate strong rotational force. Efficiency is improved because it has no slip loss, which always occurs in the normal induction motor, and noise is also reduced due to its low torque ripple design. In addition, because the BLDC inverter compressor has the back pressure structure in which the interior of the compressor is maintained at a high pressure, the compression efficiency for refrigerant is improved. The compressor is also a high pressure type that makes oil lubrication smoother. Compared to the existing models, the BLDC inverter compressor has more improved performance and reliability. It is the most suitable scroll inverter compressor for the VRF system and performs the role of a strong human hear t in the VRS 3 with its outstanding performance and high reliability.

4


Tropical Multi V III

Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.

Tropical Multi V Mini

5 New optimized refrigerant distributor Tropical Multi V Water II

With the new optimal distributor design applied to the heat exchanger, the product distributes refrigerant to the heat exchanger uniformly so that its entire area can be used efficiently. As a result, both of heat exchange efficiency and system performance are improved.

6

6 New FDD technology Just like a comprehensive automotive diagnostic s y s te m , t h e V R S 3 i s a l s o e q u i p p e d w i t h a comprehensive diagnostic system that carries out automatic test run, refrigerant amount check, and real-time inspection and back-up operation for parts and sensors, maximizing reliability of the product.

New FDD technology

New & Improved function

eco V

1. Automatic test run 2. Refrigerant amount check 3. Real-time diagnosis (refrigerant and parts) 4. Real-time back-up (compressor and sensors)

Automotive self-diagnostic system

FDD (Fault Detection & Diagnosis)

V-Net & Accessory


Enjoy a Clean & Comfortable life with Xtreme VRS MINI


Tropical Multi V III

VRS MINI can be easily installed in small offices and shops. Designed for lowTropical Multi V Mini

noise operation, it ensures a pleasant air conditioned environment.

Tropical Multi V Water II Multi V series Indoor unit eco V V-Net & Accessory


Enhanced Comfort • Night silent operation silent operation • High COP

HP

• Noise level (dBA)

3Ø, 380V Cooling

Heating

4HP

4.3

4.3

5HP

4.0

4.1

6HP

3.7

3.9

• Long pipe length Total piping length Longest piping length (Equivalent) Longest piping length after 1st branch

300m 150m(175m) 40m

Level difference Between ODU~IDU

50m(40m*)

Level difference Between IDU~IDU

15m

50 4HP

51

52

46

5HP

6HP

STEP 1

Day-time

*Outdoor unit is lower than indoor unit.

Wide Range of Operation / Cooling at 54ºC • Cooling operation range : -5ºC to 54ºC • Heating operation range : -20ºC to 16ºC

54ºC

43

40

STEP 2

STEP 3

Night time (Based on 4HP)


Tropical Multi V III

Outdoor Unit MULTI V MINI uses the cutting-edge, artificial intelligence control to obtain efficient operation and reduced noise.

Tropical Multi V Mini

Max. 9 Indoor Units Connectable

1

6

2

3

7

4

8

5

9 units

Tropical Multi V Water II

• Maximum 9 indoor units can be connected to one single outdoor unit with 100% indoor unit combination. - 9 indoor units for 6HP - 8 indoor units for 5HP - 6 indoor units for 4HP

(Based on 6 HP model)

• Maximum 9 indoor units can be connected to one single outdoor unit with 100% indoor unit combination. - 9 indoor units for 6HP - 8 indoor units for 5HP - 6 indoor units for 4HP 01

Inner SVC valve - 4 Way piping is possible (Front, Rear, Right, Down) - Excellent exterior

03

eco V

01

Multi V series Indoor unit

Easy To Service

Compact Design & Ez SVC - Remove 3 pieces of screw for SVC - Front panel removal system

3 pieces of screw

1 Way

02

4 Way

Convenient moving handle

02

03

V-Net & Accessory

Ez SVC


Enjoy a Clean & Comfortable life with VRS WaterAce


Tropical Multi V III

Cooling tower

VRS WaterAce represents both effective and safe system with great performance regardless of external conditions, such as ambient temperature, building wind effects in VRS WaterAce Outside unit

Water pipe

Tropical Multi V Water II

VRS WaterAce Indoor unit

high rising building.

Tropical Multi V Mini

Refrigerant pipe

Multi V series Indoor unit eco V

Boiler

V-Net & Accessory


Economic Water System There is no efficiency reduction from environmental condition such as a contrar y wind, building wind, harsh outside temperature. This is a good solution for high-rise building.

• High efficiency system regardless of external conditions

Outside temp

Wind

• Optimized control by variable load

Easy Installation • Light weight & compact size - Installation space is reduced up to 60% • Easy piping work - Refrigerant & water pipe connection at front side Water piping

Refrigerant piping

Refrigerant piping

Water piping

Outside Unit

A company


Tropical Multi V III

Outside Unit Your life will be upgraded through the state-of-the-art-technology of MULTI V WATER II.

Tropical Multi V Mini

Wide View The reduced installation space required for the outdoor unit has resulted in a more usable space.

Tropical Multi V Water II

Narrow view

Wide view VRS WaterAce

Conventional

Total piping length

300m

Longest piping length (Equivalent)

150m(175m)

Level difference 50m

40m

Longest piping length after 1st branch Level difference Between ODU~IDU

50m(40m*)

Level difference Between IDU~IDU

15m

Longest piping length 40m (after 1st branch)

*Outdoor unit is lower than indoor unit.

Between Indoor units 15m

Multi V series Indoor unit

Longest Piping Length

High Efficiency & Reliability D/Pipe type Plate type

20.0

15.5

0.12

29%

4.1

50% 0.06

Installation area(m2)

3.5

17%

Efficiency

Compressor back up operation 1. One compressor failure 2. Error code is displayed

3. Back-up by field setting (Dip S/W) 4. Continuous operation

V-Net & Accessory

Reliability (MPa)

eco V

Comparison between plate type and double pipe type


SPECIFICATIONS

HP

8

Model Name

Capacity

BTON10LUH3-X

BTON12LUH3-X

Independent Unit

BTON08LUH3-X

BTON10LUH3-X

BTON12LUH3-X

RT

6.4

8.0

9.6

kW

22.4

28.0

33.6 114,600

76,400

95,500

RT

6.4

7.1

8.1

kW

22.4

25.0

28.5

Btu/h Cooling (T_air : 46ºC)

76,400

85,300

97,200

RT

7.17

8.96

10.75

kW

25.2

31.5

37.8

85,300

107,500

128,000

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

mm

(920×1,680×760)×1

(920×1,680×760)×1

(1,240×1,680×760)×1

inch

Btu/h Heating

Btu/h Power Supply

Ø , V, Hz

Dimensions(WxHxD) Net Weight

(36.2×66.1×29.9)×1

(36.2×66.1×29.9)×1

(48.8×66.1×29.9)×1

kg

240 × 1

240 × 1

270 × 1

lbs

529 × 1

529 × 1

595 × 1

Warm Gray

Warm Gray

Warm Gray

Morning Gray

Morning Gray

Morning Gray

13

16

20

*HSS DC Scroll

*HSS DC Scroll

*HSS DC Scroll

kW

(5.143+4.95)x1

(5.143+4.95)x1

(5.143+4.95)x1

kg

6.4

6.4

7.0

R410A

R410A

R410A

Casing color Number of outdoor units(Max) Type

Refrigerant

Charge

Motor Output x Number Refrigerant name Control Heat Exchanger Fan

Drive Air Flow Rate(High)

CMM

Motor Output x Number

kW

EEV

EEV

EEV

Gold fin

Gold fin

Gold fin

DC INVERTER

DC INVERTER

DC INVERTER

180

190

240

0.75 x 1

0.75 x 1

0.6 x 2

dB(A)±3

57

58

61

Liquid Pipes

mm(inch)

Ø9.52(3/8)

Ø9.52(3/8)

Ø12.7(1/2)

Gas Pipes

mm(inch)

Ø19.05(3/4)

Ø22.2(7/8)

Sound pressure levels Pipe Connections

12

BTON08LUH3-X

Cooling (T_air : 35ºC)

Compressor

10

Combination Unit

Ø28.58(11/8) *HSS DC Scroll : High Side Shell DC Scroll

Note 1. Capacities are based on following conditions: *Cooling:

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB

**Cooling

-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB

Piping Length

-Interconnecting Piping Length 7.5m -Level Difference of Zero

2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification


HP

14

Model Name

Capacity

BTON16LUH3-X

BTON18LUH3-X

Independent Unit

BTON14LUH3-X

BTON16LUH3-X

BTON08LUH3-X

BTON08LUH3-X

BTON08LUH3-X

BTON10LUH3-X

Cooling (T_air : 46ºC)

Heating

11.1

12.7

12.7

39.2

44.8

44.8

50.4

133,800

152,900

152,800

171,900

RT

10.0

11.5

12.7

13.5

kW

35.3

40.3

44.8

47.4

120,400

137,600

152,800

161,700

RT

12.48

14.22

14.33

16.12

kW

43.9

50.0

50.4

56.7

149,800

170,600

170,600

192,800

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3, 380~415, 50

3Ø, 380V~415V, 50Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

3ø, 380V, 60Hz

3Ø, 380V, 60Hz

mm

(1,240×1,680×760)×1

(1,240×1,680×760)×1

(920×1,680×760)×2

(920×1,680×760)×2

inch

Btu/h Power Supply

Ø , V, Hz

Dimensions(WxHxD) Net Weight

(48.8×66.1×29.9)×1

(48.8×66.1×29.9)×1

(36.2×66.1×29.9)×2

(36.2×66.1×29.9)×2

kg

340 × 1

350 × 1

240 × 2

240 × 2

lbs

749 × 1

771× 1

529 × 2

529 × 2

Warm Gray

Warm Gray

Warm Gray

Warm Gray

Morning Gray

Morning Gray

Morning Gray

Morning Gray

23

26

26

29

*HSS DC Scroll

*HSS DC Scroll

HSS DC Scroll

*HSS DC Scroll

kW

(5.143+4.95+4.95)x1

(5.143+4.95+4.95)x1

(5.143+4.95)x2

(5.143+4.95)x2

kg

7.5

9.0

12.8

6.4 x 2

R410A

R410A

R410A

R410A

EEV

EEV

EEV

EEV

Gold fin

Gold fin

Gold fin

Gold fin

DC INVERTER

DC INVERTER

DC INVERTER

DC INVERTER

250

250

360

370

0.6 x 2

0.6 x 2

0.75 x 2

0.75 x 2

Casing color Number of outdoor units(Max)

Charge

Motor Output x Number Refrigerant name Control Heat Exchanger Fan

Drive Air Flow Rate(High)

CMM

Motor Output x Number

kW dB(A)±3

62

62

60

61

Liquid Pipes

mm(inch)

Ø12.7(1/2)

Ø12.7(1/2)

Ø12.7(1/2)

Ø15.88(5/8)

Gas Pipes

mm(inch)

Ø28.58(11/8)

Ø 28.58(11/8)

Ø28.58(11/8)

Ø28.58(11/8)

Sound pressure levels Pipe Connections

14.3

RT kW

Btu/h

Refrigerant

18

BTON16LUH3-X

Btu/h

Type

16(Energy Saving)

BTON14LUH3-X

Cooling (T_air : 35ºC)

Compressor

16(Space Saving)

Combination Unit

*HSS DC Scroll : High Side Shell DC Scroll Note 1. Capacities are based on following conditions: *Cooling:

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB

**Cooling

-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB

Piping Length

-Interconnecting Piping Length 7.5m -Level Difference of Zero

2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification


SPECIFICATIONS

HP

20

Model Name

Capacity

24

BTON20LUH3-X

BTON22LUH3-X

BTON24LUH3-X

Independent Unit

BTON10LUH3-X

BTON10LUH3-X

BTON10LUH3-X

BTON10LUH3-X

BTON12LUH3-X

BTON14LUH3-X

Cooling (T_air : 35ºC)

Cooling (T_air : 46ºC)

15.9

17.5

56

61.6

67.2

191,000

210,100

229,300

RT

14.2

15.2

17.1

kW

50

53.5

60.3

170,600

182,500

205,700

RT

17.91

19.70

21.44

kW

63.0

69.3

75.4

215,000

235,500

257,300

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

mm

(920×1,680×760)×2

(920×1,680×760)×1

(920×1,680×760)×1

(1,240×1,680×760)×1

(1,240×1,680×760)×1

inch

(36.2×66.1×29.9)×2

(36.2×66.1×29.9)×1

(36.2×66.1×29.9)×1

(48.8×66.1×29.9)×1

(48.8×66.1×29.9)×1

Btu/h Heating

Btu/h Power Supply

Ø , V, Hz

Dimensions(WxHxD)

Net Weight

kg

240 × 2

240 × 1 + 270 × 1

240 × 1 + 340 × 1

lbs

529 × 2

529 × 1 + 595 × 1

529 × 1 + 749 × 1

Warm Gray

Warm Gray

Warm Gray

Morning Gray

Morning Gray

Morning Gray

Casing color Number of outdoor units(Max) Type Motor Output x Number

19.1

RT kW Btu/h

Compressor

22

Combination Unit

kW

32

35

39

*HSS DC Scroll

*HSS DC Scroll

*HSS DC Scroll

(5.143+4.95)x2

(5.143+4.95) x 2

(5.143+4.95)x1 (5.143+4.95+4.95)x1

Refrigerant

Charge

kg

Refrigerant name Control Heat Exchanger Fan

Drive Air Flow Rate(High)

CMM

Motor Output x Number

6.4 x 1 + 7.0 x 1

6.4 x 1 + 7.5 x 1

R410A

R410A

R410A

EEV

EEV

EEV

Gold fin

Gold fin

Gold fin

DC INVERTER

DC INVERTER

DC INVERTER

380

430

440

0.75 x 2

0.75 + (0.6x2)

0.75 + (0.6x2)

dB(A)±3

61

62.8

63.5

Liquid Pipes

mm(inch)

Ø15.88(5/8)

Ø15.88(5/8)

Ø15.88(5/8)

Gas Pipes

mm(inch)

Ø28.58(11/8)

Ø28.58(11/8)

Ø34.9(13/8)

Sound pressure levels Pipe Connections

kW

6.4 x 2

*HSS DC Scroll : High Side Shell DC Scroll Note 1. Capacities are based on following conditions: *Cooling:

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB

**Cooling

-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB

Piping Length

-Interconnecting Piping Length 7.5m -Level Difference of Zero

2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification


HP

26

Model Name

Capacity

28

30

32

Combination Unit

BTON26LUH3-X

BTON28LUH3-X

BTON30LUH3-X

BTON32LUH3-X

Independent Unit

BTON10LUH3-X

BTON12LUH3-X

BTON14LUH3-X

BTON16LUH3-X

BTON16LUH3-X

BTON16LUH3-X

BTON16LUH3-X

BTON16LUH3-X

Cooling (T_air : 35ºC)

RT

20.7

22.3

23.9

kW

72.8

78.4

84

89.6

248,400

267,500

286,700

305,800

RT

18.6

19.6

21.5

22.9

kW

65.3

68.8

75.6

80.6

222,900

234,800

258,000

275,200

RT

23.17

24.96

26.70

28.43

kW

81.5

87.8

93.9

100.0

278,100

298,600

320,400

341,200

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

(920×1,680×760)×1

(1,240×1,680×760)×2

(1,240×1,680×760)×2

(1,240×1,680×760)×2

(48.8×66.1×29.9)×2

(48.8×66.1×29.9)×2

(48.8×66.1×29.9)×2 350 × 2

Btu/h Cooling (T_air : 46ºC)

Btu/h Heating

Btu/h Power Supply

Ø , V, Hz

Dimensions(WxHxD)

mm

25.5

(1,240×1,680×760)×1 inch

(36.2×66.1×29.9)×1 (48.8×66.1×29.9)×1

Net Weight

kg

240 × 1 + 350 × 1

270 × 1 + 350 × 1

340 × 1 + 350 × 1

lbs

529 × 1 + 771 × 1

595 × 1 + 771 × 1

749 × 1 + 771 × 1

771 × 2

Warm Gray

Warm Gray

Warm Gray

Warm Gray

Morning Gray

Morning Gray

Morning Gray

Morning Gray

42

45

49

52

*HSS DC Scroll

*HSS DC Scroll

*HSS DC Scroll

*HSS DC Scroll

(5.143+4.95+4.95)x2

(5.143+4.95+4.95)x2

Casing color Number of outdoor units(Max) Compressor

Type Motor Output x Number

Refrigerant

Charge

(5.143+4.95)x1

(5.143+4.95)x1

(5.143+4.95+4.95)x1

(5.143+4.95+4.95)

6.4 x 1 + 9.0 x 1

7.0 x 1 + 9.0 x 1

7.5 x 1 + 9.0 x 1

9.0 x 2

R410A

R410A

R410A

R410A

kW kg

Refrigerant name Control Heat Exchanger Fan

Drive Air Flow Rate(High)

CMM

Motor Output x Number Sound pressure levels Pipe Connections

kW

EEV

EEV

EEV

EEV

Gold fin

Gold fin

Gold fin

Gold fin

DC INVERTER

DC INVERTER

DC INVERTER

DC INVERTER

440

490

500

500

0.75 + (0.6x2)

(0.6x2) x 2

(0.6x2) x 2

(0.6x2) x 2

dB(A)±3

63.5

64.5

65

65

Liquid Pipes

mm(inch)

Ø19.05(3/4)

Ø19.05(3/4)

Ø19.05(3/4)

Ø19.05(3/4)

Gas Pipes

mm(inch)

Ø34.9(13/8)

Ø34.9(13/8)

Ø34.9(13/8)

Ø34.9(13/8)

*HSS DC Scroll : High Side Shell DC Scroll Note 1. Capacities are based on following conditions: *Cooling:

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB

**Cooling

-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB

Piping Length

-Interconnecting Piping Length 7.5m -Level Difference of Zero

2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification

38 /39


SPECIFICATIONS

HP

34

Model Name

Capacity

BTON38LUH3-X

BTON40LUH3-X

Independent Unit

BTON10LUH3-X

BTON10LUH3-X

BTON10LUH3-X

BTON12LUH3-X

BTON10LUH3-X

BTON12LUH3-X

BTON12LUH3-X

BTON12LUH3-X

BTON14LUH3-X

BTON14LUH3-X

BTON16LUH3-X

BTON16LUH3-X

Cooling (T_air : 46ºC)

RT

27.1

28.7

30.3

kW

95.2

100.8

106.4

112

324,800

343,900

363,000

382,100

RT

24.3

25.2

26.7

27.7

kW

85.3

88.8

93.8

97.3

291,000

302,900

320,100

332,000

RT

30.40

32.19

33.92

35.71

kW

106.9

113.2

119.3

125.6

364,800

385,300

406,100

426,600

3, 380~415, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3ø, 380V, 60Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

(920×1,680×760)×2

(920×1,680×760)×1

(920×1,680×760)×1

(1,240×1,680×760)×3

(1,240×1,680×760)×1

(1,240×1,680×760)×2

(1,240×1,680×760)×2

(36.2×66.1×29.9)×2

(36.2×66.1×29.9)×1

(36.2×66.1×29.9)×1

(48.8×66.1×29.9)×1

(48.8×66.1×29.9)×2

(48.8×66.1×29.9)×2

kg

240 × 2 + 340 × 1

240×1 + 270×1 + 340x1

240×1 + 270×1 + 350x1

270 × 2 + 350 x 1

lbs

529 × 2 + 749 × 1

529×1 + 595×1 + 749x1

529×1 + 595×1 + 771x1

595 × 2 + 771 x 1

Warm Gray

Warm Gray

Warm Gray

Warm Gray

Morning Gray

Morning Gray

Morning Gray

Morning Gray

Btu/h Heating

Btu/h Power Supply

Ø , V, Hz

Dimensions(WxHxD)

mm inch

Net Weight Casing color Number of outdoor units(Max) Type Motor Output x Number Charge

Sound pressure levels

61

64

*HSS DC Scroll

*HSS DC Scroll

(5.143+4.95)x2

(5.143+4.95)x2

(5.143+4.95+4.95)x1

(5.143+4.95+4.95)x1

6.4 x 2 + 7.5 x 1

6.4 x 1 + 7.0 x 1 + 7.5 x 1

6.4 x 1 + 7.0 x 1 + 9.0 x 1

7.0 x 2 + 9.0 x 1

R410A

R410A

R410A

R410A

EEV

EEV

EEV

EEV

Gold fin

Gold fin

Gold fin

Gold fin

DC INVERTER

DC INVERTER

DC INVERTER

DC INVERTER

630

680

680

730

0.75x 2 + (0.6x2)

0.75 + (0.6x2) x 2

0.75 + (0.6x2) x 2

(0.6x2) x 3

Drive

Pipe Connections

58 *HSS DC Scroll (5.143+4.95)x2

Heat Exchanger CMM kW

55 HSS DC Scroll

(5.143+4.95+4.95)x1

Control

Motor Output x Number

(48.8×66.1×29.9)×3

(5.143+4.95)x2

kg

Air Flow Rate(High)

31.8

(5.143+4.95+4.95) x 1

kW

Refrigerant name

Fan

40

BTON36LUH3-X

Btu/h

Refrigerant

38

BTON34LUH3-X

Cooling (T_air : 35ºC)

Compressor

36

Combination Unit

dB(A)±3

65

65.4

65.4

66.1

Liquid Pipes

mm(inch)

Ø19.05(3/4)

Ø19.05(3/4)

Ø19.05(3/4)

Ø19.05(3/4)

Gas Pipes

mm(inch)

Ø34.9(13/8)

Ø41.3(15/8)

Ø41.3(15/8)

Ø41.3(15/8)

*HSS DC Scroll : High Side Shell DC Scroll Note 1. Capacities are based on following conditions: *Cooling:

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB

**Cooling

-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB

Piping Length

-Interconnecting Piping Length 7.5m -Level Difference of Zero

2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification


HP

42

Model Name

Capacity

BTON46LUH3-X

BTON48LUH3-X

Independent Unit

BTON12LUH3-X

BTON12LUH3-X

BTON14LUH3-X

BTON16LUH3-X

BTON14LUH3-X

BTON16LUH3-X

BTON16LUH3-X

BTON16LUH3-X

BTON16LUH3-X

BTON16LUH3-X

BTON16LUH3-X

BTON16LUH3-X

RT

33.4

35.0

36.6

38.2

kW

117.6

123.2

128.8

134.4 458,700

Btu/h

401,300

420,400

439,600

RT

29.6

31.0

33.0

34.4

kW

104.1

109.1

115.9

120.9

Btu/h Heating

355,200

372,400

395,600

412,800

RT

37.45

39.18

40.92

42.65

kW

131.7

137.8

143.9

150.0

448,400

469,200

491,000

511,800

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V~415V, 50Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

3Ø, 380V, 60Hz

mm

(1,240×1,680×760)×3

(1,240×1,680×760)×3

(1,240×1,680×760)×3

(1,240×1,680×760)×3

inch

(48.8×66.1×29.9)×3

(48.8×66.1×29.9)×3

(48.8×66.1×29.9)×3

(48.8×66.1×29.9)×3

kg

270×1 + 340×1 + 350x1

270 × 1 + 350 x 2

340 x 1 + 350 x 2

350 x 3

lbs

595×1 + 749×1 + 771x1

595 × 1 + 771 x 2

749 x 1 + 771 x 2

771 x 3

Warm Gray

Warm Gray

Warm Gray

Warm Gray

Morning Gray

Morning Gray

Morning Gray

Morning Gray

64

64

64

64

*HSS DC Scroll

*HSS DC Scroll

*HSS DC Scroll

*HSS DC Scroll

(5.143+4.95+4.95)x3

(5.143+4.95+4.95)x3

Btu/h Power Supply

Ø , V, Hz

Dimensions(WxHxD)

Net Weight Casing color Number of outdoor units(Max) Type Motor Output x Number Charge

kW kg

(5.143+4.95)x1

(5.143+4.95)x1

(5.143+4.95+4.95)x2

(5.143+4.95+4.95)x2

7.0 x 1 + 7.5 x 1 + 9.0 x 1

7.0 x 1 + 9.0 x 2

7.5 x 1 + 9.0 x 2

9.0 x 3

R410A

R410A

R410A

R410A

Refrigerant name Control Heat Exchanger Fan

Drive Air Flow Rate(High)

CMM

Motor Output x Number Sound pressure levels Pipe Connections

48

BTON44LUH3-X

Cooling (T_air : 46ºC)

Refrigerant

46

BTON42LUH3-X

Cooling (T_air : 35ºC)

Compressor

44

Combination Unit

kW

EEV

EEV

EEV

EEV

Gold fin

Gold fin

Gold fin

Gold fin

DC INVERTER

DC INVERTER

DC INVERTER

DC INVERTER

740

740

750

750

(0.6x2) x 3

(0.6x2) x 3

(0.6x2) x 3

(0.6x2) x 3

dB(A)±3

66.5

66.5

66.8

66.8

Liquid Pipes

mm(inch)

Ø19.05(3/4)

Ø19.05(3/4)

Ø19.05(3/4)

Ø19.05(3/4)

Gas Pipes

mm(inch)

Ø41.3(15/8)

Ø41.3(15/8)

Ø41.3(15/8)

Ø41.3(15/8)

*HSS DC Scroll : High Side Shell DC Scroll Note 1. Capacities are based on following conditions: *Cooling:

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB

**Cooling

-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB

Piping Length

-Interconnecting Piping Length 7.5m -Level Difference of Zero

2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification

40 /41


SPECIFICATIONS

HP

4

Model

BTON04LUH-X

Capacity

*Cooling

RT

3.2

kW

11.2

kcal/h

9,632

Btu/h

38,200

**Cooling(46)

2.6

RT

9.2

kW kcal/h

7,910

Btu/h

31,400

Heating

RT

3.6

kW

12.5 10,750

kcal/h

42,700

Btu/h Power Supply

3 / 380~415 / 50

ø, V, Hz

3 / 380 / 60 Dimensions

(WxHxD)

Net Weight

mm

950x1380x330

inch

37.4x54.3x13.0 107

kg

Warm Gray

Casing Color

6

Max. Number of Connectable Indoor Units

100%

Ratio of the Connectable Indoor Units Compressor (#1)

DC INV Rotary

Type Piston Displacement

m3/h

42.5

Number of Revolutions

r.p.m

3,600x1

Motor Output x Number of Units kW

4.0x1

Oil charge volume

1,300

cc

FVC68D

Oil Type Refrigerant

R410A

Type Charge

3.0

kg

EEV

Control

Gold Fin

Heat Exchanger Fan

BLDC Inverter

Drive

Side

Discharge Direction(Side/Top)

110

Air Flow Rate x No. of Fan m3/min Motor output

0.124x2

kW

Sound Level

Sound Pressure

dB(A)+3

50/52

Pipe Connections

Liquid

mm(inch)

ø9.52(3/8)

Gas

mm(inch)

ø15.88(5/8)

Note 1. Capacities are based on following conditions: *Cooling: Heating:

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB -Indoor Temperature 20ºC(68ºF) DB/15ºC(59ºF) WB -Outdoot Temperature 7ºC(44.6ºF) DB/6ºC(42.8ºF) WB

2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification

**Cooling Piping Length

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB -Interconnecting Piping Length 7.5m -Level Difference of Zero


SPECIFICATIONS

HP Model Capacity

RT

4.0

4.4

14.0

15.5

kcal/h

12,040

13,330

Btu/h

47,800

52,900

**Cooling(46)

RT

2.9

3.3

kW

10.3

11.5

kcal/h

8,860

9,890

Btu/h

35,100

39,200

RT

4.5

5.1

kW

16.0

18.0

kcal/h

13,760

15,480

Btu/h

54,600

61,400

3 / 380~415 / 50

3 / 380~415 / 50

Heating

ø, V, Hz

Dimensions

6 BTON06LUH-X

kW

*Cooling

Power Supply

5 BTON05LUH-X

(WxHxD)

Net Weight

3 / 380 / 60

3 / 380 / 60

mm

950x1380x330

950x1380x330

inch

37.4x54.3x13.0

37.4x54.3x13.0

kg

Casing Color

9 100%

DC INV Rotary

DC INV Rotary

Piston Displacement

m3/h

42.5

42.5

Number of Revolutions

r.p.m

3,600x1

3,600x1

Motor Output x Number of Units kW

4.0x1

4.0x1

Oil charge volume

1,300

1,300

FVC68D

FVC68D

R410A

R410A

cc

Oil Type Refrigerant

Type Charge

kg

Control

3.0

3.0

EEV

EEV

Gold Fin

Gold Fin

BLDC Inverter

BLDC Inverter

Discharge Direction(Side/Top)

Side

Side

Air Flow Rate x No. of Fan m3/min

110

110

0.124x2

0.124x2

Heat Exchanger Fan

Warm Gray

8

Ratio of the Connectable Indoor Units Type

107

Warm Gray 100%

Max. Number of Connectable Indoor Units Compressor (#1)

107

Drive

Motor output

kW

Sound Level

Sound Pressure

dB(A)+3

51/53

52/54

Pipe Connections

Liquid

mm(inch)

ø9.52(3/8)

ø9.52(3/8)

Gas

mm(inch)

ø15.88(5/8)

ø19.05(3/4)

Note 1. Capacities are based on following conditions: *Cooling: Heating:

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB -Indoor Temperature 20ºC(68ºF) DB/15ºC(59ºF) WB -Outdoot Temperature 7ºC(44.6ºF) DB/6ºC(42.8ºF) WB

**Cooling Piping Length

-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB -Interconnecting Piping Length 7.5m -Level Difference of Zero

2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification

42 /43


SPECIFICATIONS

HP Model Name

10

20

30

Combination Unit

BTO*10LA-X

BTO*20LA-X

BTO*30LA-X

Independent Unit

BTO*10LA-X

BTO*20LA-X

BTO*20LA-X BTO*10LA-X

Capacity Power Input COP

Cooling

kW

28.0

56.0

84.0

Heating

kW

31.5

63.0

94.5

Cooling

kW

5.6

11.2

16.8

Heating

kW

5.8

11.7

17.5

Cooling

5.00

5.00

5.00

Heating

5.43

5.38

5.40

ø, V, Hz

3, 380~415, 50

3, 380~415, 50

3, 380~415, 50

mm

772x1,120x547

772x1,120x547

(772x1,120x547)x2

170

238

170+238

Powersupply Dimensions (WxHxD) Net Weight

kg

Warm Gray

Color Noise Level Heat Exchanger

dBA

Stainless Steel Plate

Max. Pressure resistance kgf/cm2 Head loss

kpa

Rated Water flow Compressor

LPM

kg

45

43

26.5+43

192

192+96

96

DC Inverter Scroll / Constant Speed Scroll 3 2

R410A

R410A

R410A

7.3

8.8

8.8+7.3

Control

EEV

EEV

EEV

Oil Type

FVC68D(PVE)

FVC68D(PVE)

FVC68D(PVE) (2.325±10)x2+2.325±70

L

2.325±10

2.325±10+2.325±70

Liquid Pipes

mm(inch)

9.52(3/8)

12.7(1/2)

15.88(5/8)

Gas Pipes

mm(inch)

22.2(7/8)

28.85(1 1/8)

34.9(1 3/8)

Oil Charge Amount Pipe Connctions

45

1

Type Charge

Refrigerant Oil

45 26.5 DC Inverter Scroll

Type Number of compressors

Refrigerant

53

51

51

Type

Inlet

PT32

PT40

PT32 + PT40

Outlet

PT32

PT40

PT32 + PT40

Drain Outlet

PT20

PT20

PT20

Number of outdoor unit

1

1

2

Number of connectable indoor units

16

32

49

Water Connection

Ratio of the connectable indoor units

50 ~ 130%

Longest piping length / Level difference

150m / 50m

* N : Heat Pump B : Heat Recovery Note 1. Capacities are based on following conditions: Cooling: -Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Water inlet temperature 30ºC(86ºF) Interconnecting piping length 7.5m Level difference of zero 2. Capacities are net capacities 3. Due to our policy of innovation some specification may be changed without prior notification 4. EEV : Electronic Expansion Valve

Heating:

-Indoor Temperature 20ºC(68ºF) DB -Water inlet temperature 20ºC(86ºF)


HP Model Name

Capacity Power Input COP

40

50

60

Combination Unit

BTO*40LA-X

BTO*50LA-X

BTO*60LA-X

Independent Unit

BTO*20LA-X

BTO*20LA-X

BTO*20LA-X

BTO*20LA-X

BTO*20LA-X

BTO*20LA-X

BTO*10LA-X

BTO*20LA-X

Cooling

kW

112.0

140.0

168.0

Heating

kW

126.0

157.5

189.0

Cooling

kW

22.4

28.0

33.6

Heating

kW

23.4

29.2

35.1

Cooling

5.00

5.00

5.00

Heating

5.38

5.39

5.38

3, 380~415, 50

3, 380~415, 50

3, 380~415, 50

(772x1,120x547)x2

(772x1,120x547)x3

(772x1,120x547)x3

238+238

238+238+170

238+238+238

Powersupply

ø, V, Hz

Dimensions (WxHxD)

mm

Net Weight

kg

Warm Gray

Color Noise Level Heat Exchanger

Stainless Steel Plate 45

45

45

kpa

43+43

26.5+43+43

43+43+43

LPM

192+192

192+192+96

192+192+192

4

DC Inverter Scroll / Constant Speed Scroll 5

6

R410A

R410A

R410A 8.8+8.8+8.8

Max. Pressure resistance kgf/cm2 Head loss Rated Water flow Compressor

Type Number of compressors

Refrigerant

Type

8.8+8.8

7.3+8.8+8.8

Control

EEV

EEV

EEV

Oil Type

FVC68D(PVE)

FVC68D(PVE)

FVC68D(PVE) (2.325±10)x3+(2.325±70)x3

Charge Refrigerant Oil

56

55

54

dBA Type

kg

(2.325±10)x2+(2.325±70)x2

(2.325±10)x3+(2.325±70)x2

Liquid Pipes

mm(inch)

19.05(3/4)

19.05(3/4)

19.05(3/4)

Gas Pipes

mm(inch)

41.3(1 5/8)

41.3(1 5/8)

41.3(1 5/8)

Inlet

PT40 + PT40

PT32+PT40+PT40

PT40+PT40+PT40

Outlet

PT40 + PT40

PT32+PT40+PT40

PT40+PT40+PT40

PT20

PT20

PT20

Number of outdoor unit

2

3

3

Number of connectable indoor units

64

64

64

Oil Charge Amount Pipe Connctions Water Connection

L

Drain Outlet

Ratio of the connectable indoor units

50 ~ 130%

Longest piping length / Level difference

150m / 50m

* N : Heat Pump B : Heat Recovery Note 1. Capacities are based on following conditions: Cooling: -Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Water inlet temperature 30ºC(86ºF) Interconnecting piping length 7.5m Level difference of zero

Heating:

-Indoor Temperature 20ºC(68ºF) DB -Water inlet temperature 20ºC(86ºF)

2. Capacities are net capacities 3. Due to our policy of innovation some specification may be changed without prior notification 4. EEV : Electronic Expansion Valve

44 /45


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.