High Performance
BEKO VRS Systems
Enjoy a Clean & Comfortable life with Xtreme VRS 3
Contents
Outdoor Unit Xtreme VRS 3
10
Xtreme VRS MINI
28
VRS WATERACE
32
(Heat Pump, Heat Recovery)
Indoor Unit Wall Mounted
60
ART COOL
62
Ceiling Cassette
64
Ceiling Duct
68
Ceiling & Floor / Suspended
72 73
Floor Standing
74
VRS 3 Vent VRS 3 Vent
80
VRS 3 Vent DX
84
Fresh Air Intake Unit
85
AHU Kit
86
Automation & Accessory Remote Controller
96
Central Controller
100
Accessory
104
BEKO XTREME VRS 3 SERIES
2012 OUTDOOR UNIT LINE-UP | HP |
4
6
8
10
22
24
26
28
40
42
44
46
| HP |
4
5
6
7
| HP |
10
20
30
40
12
14
16
gy
18
20
g
30
32
34
36
38
48
50
60
70
80
8
9
10
11
12
50
60
70
80
90
BEKO XTREME VRS 3 SERIES
Ceiling Cassette
SRAC
2012 OUTDOOR UNIT LINE-UP kW
1.5
2.2
2.8
3.6
Btu / h
5k
7k
9k
12k
Wall Mounted 4way Cassette (570*570) 4way Cassette (840*840) 2way Cassette
Low Static
High Static
FAU
VRS 3 Vent
Floor Standing
Ceiling & Floor / Ceiling Suspended
Ceiling Concealed Duct
1way Cassette
With Case Without Case Vent Vent DX Fresh Air Intake Unit
4.5
5.6
7.1
8.2
10.6
12.3
14.1
22.4
28.0
15k
18k
24k
28k
36k
42k
48k
76k
96k
4.71, 7.46, 9.12 kW
14.1, 22.4, 28 kW
Enjoy a Clean & Comfortable life with Xtreme VRS 3
Tropical Multi V III
VRS 3 Inverter units composed of serially arranged refrigerant pipes connected
saving, simple and easy installation, and connection to different types of indoor units, making it easy to design and install.
Tropical Multi V Mini
to a single outdoor unit are an efficient system that offers outstanding energy
Tropical Multi V Water II Multi V series Indoor unit eco V V-Net & Accessory
The world’s best cooling COP • High efficiency BLDC V-scroll inverter compressor • High efficiency BLDC inverter fan motor
COP Comparison (Base on 12HP) MULTIACE VRS 3
• High air volume fan
11% UP
• Optimal heat exchanger distribution
4.12
3.7 Coefficient of Performance (COP) =
Cooling capability Energy consumption
Therefore, the higher the COP of a product, the higher its cooling and heating capability and the lower its energy consumption.
Cooling
Maximum single unit capacity of 16HP VRS 3 offers world’s largest capacity of 16HP for a single unit. The two basic modules, small unit (up to 10HP), and large unit (up to 16HP), can be combined freely. Since one outdoor unit is enough to heat and cool a large area, the design of the VRS 3 is simple and installation costs are kept to a minimum.
16HP Single Unit !!
Small 8~10HP
Large 12~16HP
Pursuing the market needs of high energy efficiency and environmental friendliness.
Tropical Multi V Mini
Technical innovation for high COP
Tropical Multi V III
Outdoor Unit
As VRS 3 has high efficiency parts, advanced interver control technology and optimal cycle control technology, the system’s unified performance has been improved. Based on these advanced technologies, the product provides customers with value through high efficiency and energy savings.
1
BLDC v-scroll inverter compressor
2
Sine wave inverter control
3
Cyclone sub-cooling circuit
4
Newly designed propeller fan
5
BLDC v-scroll inverter fan motor
6
New refrigerant distributor for the heat exchanger
7
Wide louver fins for the heat exchanger
5
3 2
Improved the energy efficiency by 11%, compared with the AC inverter compressor, by using the high efficiency BLDC inverter compressor.
Tropical Multi V Water II
4
Improved the efficiency of the compressor motor by using the sine wave DC inverter control technology.
6 7 1
Improved the cooling capability by using a cyclone sub-cooling circuit.
Achieved optimal heat exchange by using high air volume and low noise fan.
eco V
Improved efficiency by using high efficiency BLDC inverter motor, compared with the AC motor.
Improved heat exchange performance and efficiency by reducing greatly the heat exchanger’s temperature deviation from 5ºC to 1 degree by applying an optimal distributor design to the heat exchanger.
V-Net & Accessory
Improved efficiency by using wide louver fins with an increased heating area.
Extended piping length and elevation Because of the product’s use of inverter control technology and sub-cooling control circuit technology, it is possible to design a system with the world’s longest piping length and world’s highest elevation difference. With this product, since a cooling and heating system can be designed more flexibly in a high-rise building or complex facilities building, the designer’s working time is reduced, thus allowing a more efficient design.
Total piping length Actual longest piping length (Equivalent) Longest piping length after 1st branch (Conditional application) Level difference between ODU~IDU Level difference between IDU~IDU Level difference between ODU~ODU
1000m 200m (225m) 40m (90m) 110m 15m 5m
Space utilization by smaller size The product size is reduced by up to 50% compared to the existing products, reducing the required installation space greatly. This gives you more free space and thus allows for easier HVAC design.
MULTIACE
VRS 3 XTREME
16HP 10HP
16HP 20HP
25%
50%
Reduction
Reduction
MULTIACE
VRS IIl
Tropical Multi V III
Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.
Tropical Multi V Mini
Eco-friendly design We not only produce high efficiency products that have excellent energy-saving capability, but we also develop eco-friendly products with green technology that protects the earth and the environment. With these products, we are leading the world in low carbon and green development.
Tropical Multi V Water II
R410A Refrigerant
Multi V series Indoor unit
No refrigerant leakage design and production
Refrigerant recovery and reuse eco V
Refrigerant recovery
Auto leakage detection V-Net & Accessory
Maximum combination capacity of 48HP with a single pipe A combination of up to 48HP can be made using 16HP units. This makes it possible to design a HVAC system that fits into an extensive space. The usual major problems in design, such as installation space for outdoor units, pipe shaft space and piping line, are no longer an issue.
Outdoor unit combination of up to 48HP
Installation space saving - Optimal space utilization
Single pipe - Easy to design. - Cooling and heating for an extensive space - Installation cost savings
When designing a HVAC system with a total capacity of 240HP, our 48HP VRS 3 combination give you the following benefits, compared with conventional 36HP combination models
Comparison of outdoor unit installation space Conventional
• Reduces the installation space by 50%. • A large capacity design reduces the time spent on designing the HVAC system, and also reduces the construction costs.
VRS 3
Tropical Multi V III
Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.
To provide our customers with the world’s best cooling and heating performance at a minimum size, and as well as a pleasant environment created with quiet operation, VRS 3 uses various low noise technologies. It has minimized operation noise by using a compressor with BLDC motors, low noise fan motors, new soundproof technology, outdoor fans, and a newly developed shroud shape.
Multi V series Indoor unit
New designs for low operation noise
54ºC
Tropical Multi V Water II
The product has more extended continuous cooling operation range and operable range than the existing products, enabling more extensive operation. It has extended the operation range by using more enhanced inverter compressor and control technology.
Tropical Multi V Mini
Wide operating range / Cooling at 54ºC
eco V V-Net & Accessory
High static pressure fan Since the product uses a more powerful high static pressure fan, the outdoor unit can be installed not only on the roof of a building but also inside the building by using an air duct. Because of the high static pressure fans and the BLDC fan motors, a sufficient air volume can be acquired for heat exchange and no re-circulation of the discharged air currents occurs. Depending on the building structure, you can reduce the piping length by installing the outdoor unit in the machine room.
erent building structures
No stacking of high temperature air occurs due to powerful discharge of air currents even within a highrise building
Conventional model
VRS lll
Tropical Multi V III
Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.
Tropical Multi V Mini
Improved corrosion resistance with Goldfin™ Fin layer
Salt Spray Test for 15 Days
Tropical Multi V Water II
The patented chloride-induced corrosion resistant Goldfin has low corrosion and erosion rates and high hydrophilicity. Its performance will not be affected even in a humid area. (Please contact us regarding the chloride-induced corrosion resistance model.)
Flexible indoor unit combination
A combination with maximum 130% efficiency can be achieved only if the changes of the heating and cooling load and the product operation rate by time are considered
Connectable Indoor unit Capacity Up to Max 130%
Connectable Indoor unit Number Up to 64
Various Indoor units
13 types, 71 models
Multi V series Indoor unit
Since up to 64 indoor units can be connected and there are 13 types of 71 different indoor models that can be connected, a variety of designs tailored for individual construction usage can be made. Up to 130% efficiency can be achieved with different combinations.
Verify combination ratio at EPDB eco V V-Net & Accessory
Easy and safe transportation Fast and safe transportation by a forklift Forklift transportation hole Scratch prevention guide
Safety design for crane use
Transportation by a crane
Crane rope hole
Compact product design allowing transportation by an elevator Transportation by an elevator
Tropical Multi V III
Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.
Tropical Multi V Mini
Free 4-way piping connection 4-way piping design
Right Left Front
Tropical Multi V Water II
The piping lines for the outdoor unit can be connected in 4 ways (front/left/right/bottom piping), allowing various custom construction depending on the individual site. If the piping lines are installed on the floor (bottom piping), the product looks neat as they are hidden from view and, in addition, the piping lines also do not interfere with gas/liquid lines, making the installation work safe and convenient. Piping line tray work is not necessary depending on the individual site, which reduces additional working hours, and also makes maintenance easier when the product is installed in the machine room.
Bottom
Automatic test run reduce test run time by more than 60% compared to the test run in an existing product, and provides safe, reliable and convenient test run with various data backup functions. Since any general installation worker, not just a highly trained engineer, can perform a test run, the product also increases your installation competitiveness.
Multi V series Indoor unit
Intelligent simple test run
VRS 3
eco V
Conventional model
•Piping/ Communication lines •Entire room operation •Individual room operation •Reporting
•Piping/ Communication lines •Entire room operation •Individual room operation •Reporting
Automatic test run
V-Net & Accessory
•Piping/ Communication lines •Entire room operation •Individual room operation •Reporting
Automatic detection for incorrect connections In the existing products, if an installation engineer has connected a liquid line to a gas line by mistake, you have to take the trouble to check the piping line connections for the indoor units installed over the ceiling. However, VRS 3 automatically checks the connections of piping lines and communication lines with its FDD function and notifies the user if there is any problem. Usually, installation becomes more and more complex as the number of connected indoor units increases. But, with the automatic detection function of this product, installation is made easier and, when an indoor unit has a connection problem, you can take action quickly because the automatic detection function will inform you about that indoor unit.
Incorrect piping line connection (Liquid line + gas line)
Incorrect communication line connection
Real-time automatic fault prediction function With the existing products, their performance and reliability would be degraded due to a slight fault with a sensor or the EEV. However, this product allows you to check the current status for the sensors and the EEV, which are the major components for system control, through a through FDD test standard.
Outdoor unit
Indoor unit
Temperature sensor
11(16HP)
3
Pressure sensor
2
0
Based on one outdoor unit and one indoor unit, respectively
Sensor EEV
Tropical Multi V III
Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.
Tropical Multi V Mini
Pump down PUMP DOWN When an indoor unit malfunctions, this function collects the refrigerant remaining in the piping line or that unit to an outdoor unit.
Tropical Multi V Water II
When an indoor unit malfunctions, it needs to be replaced served before servicing this function automatically collects its refrigerant in outdoor unit running normally, making servicing very convenient and easy.
Multi V series Indoor unit
Automatic refrigerant charging function Calculates and automatically injects the optimal amount of refrigerant. Since the FDD algorithm calculates and automatically charges the correct amount of refrigerant without using an electronic scale, installation reliability is increased and product performance is guaranteed. Embedded with the FDD algorithm
eco V
Indicated by theLED indicator when fully charged
V-Net & Accessory
Automatic emergency back-up function When a compressor malfunctions, the other compressor that is operating normally in an outdoor unit can run automatically as a substitute, minimizing any inconvenience that may occur in an emergency situation.
Powerful Control Software This program allows you to monitor and control the operation status of the product. Since the program can be connected to either an outdoor unit or indoor unit, you can check the operation status of the product easily and conveniently any time and anywhere.
Software Cycle View
Cycle
Indoor unit control
Pursuing the market needs of high energy efficiency and environmental friendliness.
By using the core technologies, such as optimal and cutting-edge control on each part of the indoor and outdoor units, BLDC inverter compressors, and artificial intelligence, the product takes less than 10 minutes to reach the set temperature from the initial heating or cooling operation. In addition, it always creates a pleasant indoor atmosphere with no temperature variation by reducing the revolutions of the compressor and performing finer control when the temperature reaches close to the set temperature.
Multi V series Indoor unit
Fast and comfortable operation
Tropical Multi V Water II
By using the BLDC inverter compressor & fan control technology and the real-time outdoor temperature detection technology, the product is equipped with the night lownoise operation function. 8 stages of low-noise operation are possible to provide more quiet operation during the night.
Tropical Multi V Mini
Night silent operation
Tropical Multi V III
Outdoor Unit
eco V V-Net & Accessory
New & core technologies 1 BLDC inverter compressor Improved the energy efficiency by 11%, compared with the AC inverter compressor, by using the high efficiency BLDC inverter compressor.
2 New designed propeller fan (Super Aero fan)
OLD NEW
Provides low noise levels through pod-shaped design
Minimizes vortex resistance with a curved shape
Provides high air volume and high static pressure with the changed shape
Improved the energy efficiency by 11%, compared with the AC inverter compressor, by using the high efficiency BLDC inverter compressor.
2 1
3 New Sub-Cooling Circuit The sub-cooling circuit control acquires sub-cooled liquid refrigerant and thus improves the symptoms of oil recove r y de gradation and pe r for mance degradation that occur because a loss of system capability occurs throughout the piping lines. The sub-cooling circuit control is a core technology that enables the product to implement the world’s longest piping length and elevation difference technology. Sub-cooling circuit control: Extracts part of the refrigerant of the SC circuit equipped in the liquid line exit of an outdoor unit and expands that extracted refrigerant using the SC EEV to make low temperature refrigerant, and then performs heat exchange in the system using that low temperature to increase the sub-cooling rate of the system.
6
5 3
4 New BLDC inverter compressor We have developed a new compressor with better performance, higher efficiency, and a more enhanced reliability than the existing compressors. For the motor, which is the core of the compressor, the product uses a BLDC motor. The BLDC motor is a highly efficient motor, where strong ND magnetism inside the rotor produces magnetic torque and the metal part of the rotor produces reluctance torque to generate strong rotational force. Efficiency is improved because it has no slip loss, which always occurs in the normal induction motor, and noise is also reduced due to its low torque ripple design. In addition, because the BLDC inverter compressor has the back pressure structure in which the interior of the compressor is maintained at a high pressure, the compression efficiency for refrigerant is improved. The compressor is also a high pressure type that makes oil lubrication smoother. Compared to the existing models, the BLDC inverter compressor has more improved performance and reliability. It is the most suitable scroll inverter compressor for the VRF system and performs the role of a strong human hear t in the VRS 3 with its outstanding performance and high reliability.
4
Tropical Multi V III
Outdoor Unit Pursuing the market needs of high energy efficiency and environmental friendliness.
Tropical Multi V Mini
5 New optimized refrigerant distributor Tropical Multi V Water II
With the new optimal distributor design applied to the heat exchanger, the product distributes refrigerant to the heat exchanger uniformly so that its entire area can be used efficiently. As a result, both of heat exchange efficiency and system performance are improved.
6
6 New FDD technology Just like a comprehensive automotive diagnostic s y s te m , t h e V R S 3 i s a l s o e q u i p p e d w i t h a comprehensive diagnostic system that carries out automatic test run, refrigerant amount check, and real-time inspection and back-up operation for parts and sensors, maximizing reliability of the product.
New FDD technology
New & Improved function
eco V
1. Automatic test run 2. Refrigerant amount check 3. Real-time diagnosis (refrigerant and parts) 4. Real-time back-up (compressor and sensors)
Automotive self-diagnostic system
FDD (Fault Detection & Diagnosis)
V-Net & Accessory
Enjoy a Clean & Comfortable life with Xtreme VRS MINI
Tropical Multi V III
VRS MINI can be easily installed in small offices and shops. Designed for lowTropical Multi V Mini
noise operation, it ensures a pleasant air conditioned environment.
Tropical Multi V Water II Multi V series Indoor unit eco V V-Net & Accessory
Enhanced Comfort • Night silent operation silent operation • High COP
HP
• Noise level (dBA)
3Ø, 380V Cooling
Heating
4HP
4.3
4.3
5HP
4.0
4.1
6HP
3.7
3.9
• Long pipe length Total piping length Longest piping length (Equivalent) Longest piping length after 1st branch
300m 150m(175m) 40m
Level difference Between ODU~IDU
50m(40m*)
Level difference Between IDU~IDU
15m
50 4HP
51
52
46
5HP
6HP
STEP 1
Day-time
*Outdoor unit is lower than indoor unit.
Wide Range of Operation / Cooling at 54ºC • Cooling operation range : -5ºC to 54ºC • Heating operation range : -20ºC to 16ºC
54ºC
43
40
STEP 2
STEP 3
Night time (Based on 4HP)
Tropical Multi V III
Outdoor Unit MULTI V MINI uses the cutting-edge, artificial intelligence control to obtain efficient operation and reduced noise.
Tropical Multi V Mini
Max. 9 Indoor Units Connectable
1
6
2
3
7
4
8
5
9 units
Tropical Multi V Water II
• Maximum 9 indoor units can be connected to one single outdoor unit with 100% indoor unit combination. - 9 indoor units for 6HP - 8 indoor units for 5HP - 6 indoor units for 4HP
(Based on 6 HP model)
• Maximum 9 indoor units can be connected to one single outdoor unit with 100% indoor unit combination. - 9 indoor units for 6HP - 8 indoor units for 5HP - 6 indoor units for 4HP 01
Inner SVC valve - 4 Way piping is possible (Front, Rear, Right, Down) - Excellent exterior
03
eco V
01
Multi V series Indoor unit
Easy To Service
Compact Design & Ez SVC - Remove 3 pieces of screw for SVC - Front panel removal system
3 pieces of screw
1 Way
02
4 Way
Convenient moving handle
02
03
V-Net & Accessory
Ez SVC
Enjoy a Clean & Comfortable life with VRS WaterAce
Tropical Multi V III
Cooling tower
VRS WaterAce represents both effective and safe system with great performance regardless of external conditions, such as ambient temperature, building wind effects in VRS WaterAce Outside unit
Water pipe
Tropical Multi V Water II
VRS WaterAce Indoor unit
high rising building.
Tropical Multi V Mini
Refrigerant pipe
Multi V series Indoor unit eco V
Boiler
V-Net & Accessory
Economic Water System There is no efficiency reduction from environmental condition such as a contrar y wind, building wind, harsh outside temperature. This is a good solution for high-rise building.
• High efficiency system regardless of external conditions
Outside temp
Wind
• Optimized control by variable load
Easy Installation • Light weight & compact size - Installation space is reduced up to 60% • Easy piping work - Refrigerant & water pipe connection at front side Water piping
Refrigerant piping
Refrigerant piping
Water piping
Outside Unit
A company
Tropical Multi V III
Outside Unit Your life will be upgraded through the state-of-the-art-technology of MULTI V WATER II.
Tropical Multi V Mini
Wide View The reduced installation space required for the outdoor unit has resulted in a more usable space.
Tropical Multi V Water II
Narrow view
Wide view VRS WaterAce
Conventional
Total piping length
300m
Longest piping length (Equivalent)
150m(175m)
Level difference 50m
40m
Longest piping length after 1st branch Level difference Between ODU~IDU
50m(40m*)
Level difference Between IDU~IDU
15m
Longest piping length 40m (after 1st branch)
*Outdoor unit is lower than indoor unit.
Between Indoor units 15m
Multi V series Indoor unit
Longest Piping Length
High Efficiency & Reliability D/Pipe type Plate type
20.0
15.5
0.12
29%
4.1
50% 0.06
Installation area(m2)
3.5
17%
Efficiency
Compressor back up operation 1. One compressor failure 2. Error code is displayed
3. Back-up by field setting (Dip S/W) 4. Continuous operation
V-Net & Accessory
Reliability (MPa)
eco V
Comparison between plate type and double pipe type
SPECIFICATIONS
HP
8
Model Name
Capacity
BTON10LUH3-X
BTON12LUH3-X
Independent Unit
BTON08LUH3-X
BTON10LUH3-X
BTON12LUH3-X
RT
6.4
8.0
9.6
kW
22.4
28.0
33.6 114,600
76,400
95,500
RT
6.4
7.1
8.1
kW
22.4
25.0
28.5
Btu/h Cooling (T_air : 46ºC)
76,400
85,300
97,200
RT
7.17
8.96
10.75
kW
25.2
31.5
37.8
85,300
107,500
128,000
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
mm
(920×1,680×760)×1
(920×1,680×760)×1
(1,240×1,680×760)×1
inch
Btu/h Heating
Btu/h Power Supply
Ø , V, Hz
Dimensions(WxHxD) Net Weight
(36.2×66.1×29.9)×1
(36.2×66.1×29.9)×1
(48.8×66.1×29.9)×1
kg
240 × 1
240 × 1
270 × 1
lbs
529 × 1
529 × 1
595 × 1
Warm Gray
Warm Gray
Warm Gray
Morning Gray
Morning Gray
Morning Gray
13
16
20
*HSS DC Scroll
*HSS DC Scroll
*HSS DC Scroll
kW
(5.143+4.95)x1
(5.143+4.95)x1
(5.143+4.95)x1
kg
6.4
6.4
7.0
R410A
R410A
R410A
Casing color Number of outdoor units(Max) Type
Refrigerant
Charge
Motor Output x Number Refrigerant name Control Heat Exchanger Fan
Drive Air Flow Rate(High)
CMM
Motor Output x Number
kW
EEV
EEV
EEV
Gold fin
Gold fin
Gold fin
DC INVERTER
DC INVERTER
DC INVERTER
180
190
240
0.75 x 1
0.75 x 1
0.6 x 2
dB(A)±3
57
58
61
Liquid Pipes
mm(inch)
Ø9.52(3/8)
Ø9.52(3/8)
Ø12.7(1/2)
Gas Pipes
mm(inch)
Ø19.05(3/4)
Ø22.2(7/8)
Sound pressure levels Pipe Connections
12
BTON08LUH3-X
Cooling (T_air : 35ºC)
Compressor
10
Combination Unit
Ø28.58(11/8) *HSS DC Scroll : High Side Shell DC Scroll
Note 1. Capacities are based on following conditions: *Cooling:
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB
**Cooling
-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB
Piping Length
-Interconnecting Piping Length 7.5m -Level Difference of Zero
2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification
HP
14
Model Name
Capacity
BTON16LUH3-X
BTON18LUH3-X
Independent Unit
BTON14LUH3-X
BTON16LUH3-X
BTON08LUH3-X
BTON08LUH3-X
BTON08LUH3-X
BTON10LUH3-X
Cooling (T_air : 46ºC)
Heating
11.1
12.7
12.7
39.2
44.8
44.8
50.4
133,800
152,900
152,800
171,900
RT
10.0
11.5
12.7
13.5
kW
35.3
40.3
44.8
47.4
120,400
137,600
152,800
161,700
RT
12.48
14.22
14.33
16.12
kW
43.9
50.0
50.4
56.7
149,800
170,600
170,600
192,800
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3, 380~415, 50
3Ø, 380V~415V, 50Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
3ø, 380V, 60Hz
3Ø, 380V, 60Hz
mm
(1,240×1,680×760)×1
(1,240×1,680×760)×1
(920×1,680×760)×2
(920×1,680×760)×2
inch
Btu/h Power Supply
Ø , V, Hz
Dimensions(WxHxD) Net Weight
(48.8×66.1×29.9)×1
(48.8×66.1×29.9)×1
(36.2×66.1×29.9)×2
(36.2×66.1×29.9)×2
kg
340 × 1
350 × 1
240 × 2
240 × 2
lbs
749 × 1
771× 1
529 × 2
529 × 2
Warm Gray
Warm Gray
Warm Gray
Warm Gray
Morning Gray
Morning Gray
Morning Gray
Morning Gray
23
26
26
29
*HSS DC Scroll
*HSS DC Scroll
HSS DC Scroll
*HSS DC Scroll
kW
(5.143+4.95+4.95)x1
(5.143+4.95+4.95)x1
(5.143+4.95)x2
(5.143+4.95)x2
kg
7.5
9.0
12.8
6.4 x 2
R410A
R410A
R410A
R410A
EEV
EEV
EEV
EEV
Gold fin
Gold fin
Gold fin
Gold fin
DC INVERTER
DC INVERTER
DC INVERTER
DC INVERTER
250
250
360
370
0.6 x 2
0.6 x 2
0.75 x 2
0.75 x 2
Casing color Number of outdoor units(Max)
Charge
Motor Output x Number Refrigerant name Control Heat Exchanger Fan
Drive Air Flow Rate(High)
CMM
Motor Output x Number
kW dB(A)±3
62
62
60
61
Liquid Pipes
mm(inch)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø15.88(5/8)
Gas Pipes
mm(inch)
Ø28.58(11/8)
Ø 28.58(11/8)
Ø28.58(11/8)
Ø28.58(11/8)
Sound pressure levels Pipe Connections
14.3
RT kW
Btu/h
Refrigerant
18
BTON16LUH3-X
Btu/h
Type
16(Energy Saving)
BTON14LUH3-X
Cooling (T_air : 35ºC)
Compressor
16(Space Saving)
Combination Unit
*HSS DC Scroll : High Side Shell DC Scroll Note 1. Capacities are based on following conditions: *Cooling:
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB
**Cooling
-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB
Piping Length
-Interconnecting Piping Length 7.5m -Level Difference of Zero
2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification
SPECIFICATIONS
HP
20
Model Name
Capacity
24
BTON20LUH3-X
BTON22LUH3-X
BTON24LUH3-X
Independent Unit
BTON10LUH3-X
BTON10LUH3-X
BTON10LUH3-X
BTON10LUH3-X
BTON12LUH3-X
BTON14LUH3-X
Cooling (T_air : 35ºC)
Cooling (T_air : 46ºC)
15.9
17.5
56
61.6
67.2
191,000
210,100
229,300
RT
14.2
15.2
17.1
kW
50
53.5
60.3
170,600
182,500
205,700
RT
17.91
19.70
21.44
kW
63.0
69.3
75.4
215,000
235,500
257,300
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
mm
(920×1,680×760)×2
(920×1,680×760)×1
(920×1,680×760)×1
(1,240×1,680×760)×1
(1,240×1,680×760)×1
inch
(36.2×66.1×29.9)×2
(36.2×66.1×29.9)×1
(36.2×66.1×29.9)×1
(48.8×66.1×29.9)×1
(48.8×66.1×29.9)×1
Btu/h Heating
Btu/h Power Supply
Ø , V, Hz
Dimensions(WxHxD)
Net Weight
kg
240 × 2
240 × 1 + 270 × 1
240 × 1 + 340 × 1
lbs
529 × 2
529 × 1 + 595 × 1
529 × 1 + 749 × 1
Warm Gray
Warm Gray
Warm Gray
Morning Gray
Morning Gray
Morning Gray
Casing color Number of outdoor units(Max) Type Motor Output x Number
19.1
RT kW Btu/h
Compressor
22
Combination Unit
kW
32
35
39
*HSS DC Scroll
*HSS DC Scroll
*HSS DC Scroll
(5.143+4.95)x2
(5.143+4.95) x 2
(5.143+4.95)x1 (5.143+4.95+4.95)x1
Refrigerant
Charge
kg
Refrigerant name Control Heat Exchanger Fan
Drive Air Flow Rate(High)
CMM
Motor Output x Number
6.4 x 1 + 7.0 x 1
6.4 x 1 + 7.5 x 1
R410A
R410A
R410A
EEV
EEV
EEV
Gold fin
Gold fin
Gold fin
DC INVERTER
DC INVERTER
DC INVERTER
380
430
440
0.75 x 2
0.75 + (0.6x2)
0.75 + (0.6x2)
dB(A)±3
61
62.8
63.5
Liquid Pipes
mm(inch)
Ø15.88(5/8)
Ø15.88(5/8)
Ø15.88(5/8)
Gas Pipes
mm(inch)
Ø28.58(11/8)
Ø28.58(11/8)
Ø34.9(13/8)
Sound pressure levels Pipe Connections
kW
6.4 x 2
*HSS DC Scroll : High Side Shell DC Scroll Note 1. Capacities are based on following conditions: *Cooling:
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB
**Cooling
-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB
Piping Length
-Interconnecting Piping Length 7.5m -Level Difference of Zero
2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification
HP
26
Model Name
Capacity
28
30
32
Combination Unit
BTON26LUH3-X
BTON28LUH3-X
BTON30LUH3-X
BTON32LUH3-X
Independent Unit
BTON10LUH3-X
BTON12LUH3-X
BTON14LUH3-X
BTON16LUH3-X
BTON16LUH3-X
BTON16LUH3-X
BTON16LUH3-X
BTON16LUH3-X
Cooling (T_air : 35ºC)
RT
20.7
22.3
23.9
kW
72.8
78.4
84
89.6
248,400
267,500
286,700
305,800
RT
18.6
19.6
21.5
22.9
kW
65.3
68.8
75.6
80.6
222,900
234,800
258,000
275,200
RT
23.17
24.96
26.70
28.43
kW
81.5
87.8
93.9
100.0
278,100
298,600
320,400
341,200
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
(920×1,680×760)×1
(1,240×1,680×760)×2
(1,240×1,680×760)×2
(1,240×1,680×760)×2
(48.8×66.1×29.9)×2
(48.8×66.1×29.9)×2
(48.8×66.1×29.9)×2 350 × 2
Btu/h Cooling (T_air : 46ºC)
Btu/h Heating
Btu/h Power Supply
Ø , V, Hz
Dimensions(WxHxD)
mm
25.5
(1,240×1,680×760)×1 inch
(36.2×66.1×29.9)×1 (48.8×66.1×29.9)×1
Net Weight
kg
240 × 1 + 350 × 1
270 × 1 + 350 × 1
340 × 1 + 350 × 1
lbs
529 × 1 + 771 × 1
595 × 1 + 771 × 1
749 × 1 + 771 × 1
771 × 2
Warm Gray
Warm Gray
Warm Gray
Warm Gray
Morning Gray
Morning Gray
Morning Gray
Morning Gray
42
45
49
52
*HSS DC Scroll
*HSS DC Scroll
*HSS DC Scroll
*HSS DC Scroll
(5.143+4.95+4.95)x2
(5.143+4.95+4.95)x2
Casing color Number of outdoor units(Max) Compressor
Type Motor Output x Number
Refrigerant
Charge
(5.143+4.95)x1
(5.143+4.95)x1
(5.143+4.95+4.95)x1
(5.143+4.95+4.95)
6.4 x 1 + 9.0 x 1
7.0 x 1 + 9.0 x 1
7.5 x 1 + 9.0 x 1
9.0 x 2
R410A
R410A
R410A
R410A
kW kg
Refrigerant name Control Heat Exchanger Fan
Drive Air Flow Rate(High)
CMM
Motor Output x Number Sound pressure levels Pipe Connections
kW
EEV
EEV
EEV
EEV
Gold fin
Gold fin
Gold fin
Gold fin
DC INVERTER
DC INVERTER
DC INVERTER
DC INVERTER
440
490
500
500
0.75 + (0.6x2)
(0.6x2) x 2
(0.6x2) x 2
(0.6x2) x 2
dB(A)±3
63.5
64.5
65
65
Liquid Pipes
mm(inch)
Ø19.05(3/4)
Ø19.05(3/4)
Ø19.05(3/4)
Ø19.05(3/4)
Gas Pipes
mm(inch)
Ø34.9(13/8)
Ø34.9(13/8)
Ø34.9(13/8)
Ø34.9(13/8)
*HSS DC Scroll : High Side Shell DC Scroll Note 1. Capacities are based on following conditions: *Cooling:
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB
**Cooling
-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB
Piping Length
-Interconnecting Piping Length 7.5m -Level Difference of Zero
2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification
38 /39
SPECIFICATIONS
HP
34
Model Name
Capacity
BTON38LUH3-X
BTON40LUH3-X
Independent Unit
BTON10LUH3-X
BTON10LUH3-X
BTON10LUH3-X
BTON12LUH3-X
BTON10LUH3-X
BTON12LUH3-X
BTON12LUH3-X
BTON12LUH3-X
BTON14LUH3-X
BTON14LUH3-X
BTON16LUH3-X
BTON16LUH3-X
Cooling (T_air : 46ºC)
RT
27.1
28.7
30.3
kW
95.2
100.8
106.4
112
324,800
343,900
363,000
382,100
RT
24.3
25.2
26.7
27.7
kW
85.3
88.8
93.8
97.3
291,000
302,900
320,100
332,000
RT
30.40
32.19
33.92
35.71
kW
106.9
113.2
119.3
125.6
364,800
385,300
406,100
426,600
3, 380~415, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3ø, 380V, 60Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
(920×1,680×760)×2
(920×1,680×760)×1
(920×1,680×760)×1
(1,240×1,680×760)×3
(1,240×1,680×760)×1
(1,240×1,680×760)×2
(1,240×1,680×760)×2
(36.2×66.1×29.9)×2
(36.2×66.1×29.9)×1
(36.2×66.1×29.9)×1
(48.8×66.1×29.9)×1
(48.8×66.1×29.9)×2
(48.8×66.1×29.9)×2
kg
240 × 2 + 340 × 1
240×1 + 270×1 + 340x1
240×1 + 270×1 + 350x1
270 × 2 + 350 x 1
lbs
529 × 2 + 749 × 1
529×1 + 595×1 + 749x1
529×1 + 595×1 + 771x1
595 × 2 + 771 x 1
Warm Gray
Warm Gray
Warm Gray
Warm Gray
Morning Gray
Morning Gray
Morning Gray
Morning Gray
Btu/h Heating
Btu/h Power Supply
Ø , V, Hz
Dimensions(WxHxD)
mm inch
Net Weight Casing color Number of outdoor units(Max) Type Motor Output x Number Charge
Sound pressure levels
61
64
*HSS DC Scroll
*HSS DC Scroll
(5.143+4.95)x2
(5.143+4.95)x2
(5.143+4.95+4.95)x1
(5.143+4.95+4.95)x1
6.4 x 2 + 7.5 x 1
6.4 x 1 + 7.0 x 1 + 7.5 x 1
6.4 x 1 + 7.0 x 1 + 9.0 x 1
7.0 x 2 + 9.0 x 1
R410A
R410A
R410A
R410A
EEV
EEV
EEV
EEV
Gold fin
Gold fin
Gold fin
Gold fin
DC INVERTER
DC INVERTER
DC INVERTER
DC INVERTER
630
680
680
730
0.75x 2 + (0.6x2)
0.75 + (0.6x2) x 2
0.75 + (0.6x2) x 2
(0.6x2) x 3
Drive
Pipe Connections
58 *HSS DC Scroll (5.143+4.95)x2
Heat Exchanger CMM kW
55 HSS DC Scroll
(5.143+4.95+4.95)x1
Control
Motor Output x Number
(48.8×66.1×29.9)×3
(5.143+4.95)x2
kg
Air Flow Rate(High)
31.8
(5.143+4.95+4.95) x 1
kW
Refrigerant name
Fan
40
BTON36LUH3-X
Btu/h
Refrigerant
38
BTON34LUH3-X
Cooling (T_air : 35ºC)
Compressor
36
Combination Unit
dB(A)±3
65
65.4
65.4
66.1
Liquid Pipes
mm(inch)
Ø19.05(3/4)
Ø19.05(3/4)
Ø19.05(3/4)
Ø19.05(3/4)
Gas Pipes
mm(inch)
Ø34.9(13/8)
Ø41.3(15/8)
Ø41.3(15/8)
Ø41.3(15/8)
*HSS DC Scroll : High Side Shell DC Scroll Note 1. Capacities are based on following conditions: *Cooling:
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB
**Cooling
-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB
Piping Length
-Interconnecting Piping Length 7.5m -Level Difference of Zero
2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification
HP
42
Model Name
Capacity
BTON46LUH3-X
BTON48LUH3-X
Independent Unit
BTON12LUH3-X
BTON12LUH3-X
BTON14LUH3-X
BTON16LUH3-X
BTON14LUH3-X
BTON16LUH3-X
BTON16LUH3-X
BTON16LUH3-X
BTON16LUH3-X
BTON16LUH3-X
BTON16LUH3-X
BTON16LUH3-X
RT
33.4
35.0
36.6
38.2
kW
117.6
123.2
128.8
134.4 458,700
Btu/h
401,300
420,400
439,600
RT
29.6
31.0
33.0
34.4
kW
104.1
109.1
115.9
120.9
Btu/h Heating
355,200
372,400
395,600
412,800
RT
37.45
39.18
40.92
42.65
kW
131.7
137.8
143.9
150.0
448,400
469,200
491,000
511,800
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V~415V, 50Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
3Ø, 380V, 60Hz
mm
(1,240×1,680×760)×3
(1,240×1,680×760)×3
(1,240×1,680×760)×3
(1,240×1,680×760)×3
inch
(48.8×66.1×29.9)×3
(48.8×66.1×29.9)×3
(48.8×66.1×29.9)×3
(48.8×66.1×29.9)×3
kg
270×1 + 340×1 + 350x1
270 × 1 + 350 x 2
340 x 1 + 350 x 2
350 x 3
lbs
595×1 + 749×1 + 771x1
595 × 1 + 771 x 2
749 x 1 + 771 x 2
771 x 3
Warm Gray
Warm Gray
Warm Gray
Warm Gray
Morning Gray
Morning Gray
Morning Gray
Morning Gray
64
64
64
64
*HSS DC Scroll
*HSS DC Scroll
*HSS DC Scroll
*HSS DC Scroll
(5.143+4.95+4.95)x3
(5.143+4.95+4.95)x3
Btu/h Power Supply
Ø , V, Hz
Dimensions(WxHxD)
Net Weight Casing color Number of outdoor units(Max) Type Motor Output x Number Charge
kW kg
(5.143+4.95)x1
(5.143+4.95)x1
(5.143+4.95+4.95)x2
(5.143+4.95+4.95)x2
7.0 x 1 + 7.5 x 1 + 9.0 x 1
7.0 x 1 + 9.0 x 2
7.5 x 1 + 9.0 x 2
9.0 x 3
R410A
R410A
R410A
R410A
Refrigerant name Control Heat Exchanger Fan
Drive Air Flow Rate(High)
CMM
Motor Output x Number Sound pressure levels Pipe Connections
48
BTON44LUH3-X
Cooling (T_air : 46ºC)
Refrigerant
46
BTON42LUH3-X
Cooling (T_air : 35ºC)
Compressor
44
Combination Unit
kW
EEV
EEV
EEV
EEV
Gold fin
Gold fin
Gold fin
Gold fin
DC INVERTER
DC INVERTER
DC INVERTER
DC INVERTER
740
740
750
750
(0.6x2) x 3
(0.6x2) x 3
(0.6x2) x 3
(0.6x2) x 3
dB(A)±3
66.5
66.5
66.8
66.8
Liquid Pipes
mm(inch)
Ø19.05(3/4)
Ø19.05(3/4)
Ø19.05(3/4)
Ø19.05(3/4)
Gas Pipes
mm(inch)
Ø41.3(15/8)
Ø41.3(15/8)
Ø41.3(15/8)
Ø41.3(15/8)
*HSS DC Scroll : High Side Shell DC Scroll Note 1. Capacities are based on following conditions: *Cooling:
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB
**Cooling
-Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB
Piping Length
-Interconnecting Piping Length 7.5m -Level Difference of Zero
2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification
40 /41
SPECIFICATIONS
HP
4
Model
BTON04LUH-X
Capacity
*Cooling
RT
3.2
kW
11.2
kcal/h
9,632
Btu/h
38,200
**Cooling(46)
2.6
RT
9.2
kW kcal/h
7,910
Btu/h
31,400
Heating
RT
3.6
kW
12.5 10,750
kcal/h
42,700
Btu/h Power Supply
3 / 380~415 / 50
ø, V, Hz
3 / 380 / 60 Dimensions
(WxHxD)
Net Weight
mm
950x1380x330
inch
37.4x54.3x13.0 107
kg
Warm Gray
Casing Color
6
Max. Number of Connectable Indoor Units
100%
Ratio of the Connectable Indoor Units Compressor (#1)
DC INV Rotary
Type Piston Displacement
m3/h
42.5
Number of Revolutions
r.p.m
3,600x1
Motor Output x Number of Units kW
4.0x1
Oil charge volume
1,300
cc
FVC68D
Oil Type Refrigerant
R410A
Type Charge
3.0
kg
EEV
Control
Gold Fin
Heat Exchanger Fan
BLDC Inverter
Drive
Side
Discharge Direction(Side/Top)
110
Air Flow Rate x No. of Fan m3/min Motor output
0.124x2
kW
Sound Level
Sound Pressure
dB(A)+3
50/52
Pipe Connections
Liquid
mm(inch)
ø9.52(3/8)
Gas
mm(inch)
ø15.88(5/8)
Note 1. Capacities are based on following conditions: *Cooling: Heating:
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB -Indoor Temperature 20ºC(68ºF) DB/15ºC(59ºF) WB -Outdoot Temperature 7ºC(44.6ºF) DB/6ºC(42.8ºF) WB
2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification
**Cooling Piping Length
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB -Interconnecting Piping Length 7.5m -Level Difference of Zero
SPECIFICATIONS
HP Model Capacity
RT
4.0
4.4
14.0
15.5
kcal/h
12,040
13,330
Btu/h
47,800
52,900
**Cooling(46)
RT
2.9
3.3
kW
10.3
11.5
kcal/h
8,860
9,890
Btu/h
35,100
39,200
RT
4.5
5.1
kW
16.0
18.0
kcal/h
13,760
15,480
Btu/h
54,600
61,400
3 / 380~415 / 50
3 / 380~415 / 50
Heating
ø, V, Hz
Dimensions
6 BTON06LUH-X
kW
*Cooling
Power Supply
5 BTON05LUH-X
(WxHxD)
Net Weight
3 / 380 / 60
3 / 380 / 60
mm
950x1380x330
950x1380x330
inch
37.4x54.3x13.0
37.4x54.3x13.0
kg
Casing Color
9 100%
DC INV Rotary
DC INV Rotary
Piston Displacement
m3/h
42.5
42.5
Number of Revolutions
r.p.m
3,600x1
3,600x1
Motor Output x Number of Units kW
4.0x1
4.0x1
Oil charge volume
1,300
1,300
FVC68D
FVC68D
R410A
R410A
cc
Oil Type Refrigerant
Type Charge
kg
Control
3.0
3.0
EEV
EEV
Gold Fin
Gold Fin
BLDC Inverter
BLDC Inverter
Discharge Direction(Side/Top)
Side
Side
Air Flow Rate x No. of Fan m3/min
110
110
0.124x2
0.124x2
Heat Exchanger Fan
Warm Gray
8
Ratio of the Connectable Indoor Units Type
107
Warm Gray 100%
Max. Number of Connectable Indoor Units Compressor (#1)
107
Drive
Motor output
kW
Sound Level
Sound Pressure
dB(A)+3
51/53
52/54
Pipe Connections
Liquid
mm(inch)
ø9.52(3/8)
ø9.52(3/8)
Gas
mm(inch)
ø15.88(5/8)
ø19.05(3/4)
Note 1. Capacities are based on following conditions: *Cooling: Heating:
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoot Temperature 35ºC(95ºF) DB/24ºC(75.2ºF) WB -Indoor Temperature 20ºC(68ºF) DB/15ºC(59ºF) WB -Outdoot Temperature 7ºC(44.6ºF) DB/6ºC(42.8ºF) WB
**Cooling Piping Length
-Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Outdoor Temperature 46ºC(114.8ºF) DB/24ºC(75.2ºF) WB -Interconnecting Piping Length 7.5m -Level Difference of Zero
2. Capacities are net capacities 3. EEV : Electronic Expansion Valve 4. Wiring cable size must comply with the applicable local and national code. 5. Due to our policy of innovation some specification may be changed without prior notification
42 /43
SPECIFICATIONS
HP Model Name
10
20
30
Combination Unit
BTO*10LA-X
BTO*20LA-X
BTO*30LA-X
Independent Unit
BTO*10LA-X
BTO*20LA-X
BTO*20LA-X BTO*10LA-X
Capacity Power Input COP
Cooling
kW
28.0
56.0
84.0
Heating
kW
31.5
63.0
94.5
Cooling
kW
5.6
11.2
16.8
Heating
kW
5.8
11.7
17.5
Cooling
5.00
5.00
5.00
Heating
5.43
5.38
5.40
ø, V, Hz
3, 380~415, 50
3, 380~415, 50
3, 380~415, 50
mm
772x1,120x547
772x1,120x547
(772x1,120x547)x2
170
238
170+238
Powersupply Dimensions (WxHxD) Net Weight
kg
Warm Gray
Color Noise Level Heat Exchanger
dBA
Stainless Steel Plate
Max. Pressure resistance kgf/cm2 Head loss
kpa
Rated Water flow Compressor
LPM
kg
45
43
26.5+43
192
192+96
96
DC Inverter Scroll / Constant Speed Scroll 3 2
R410A
R410A
R410A
7.3
8.8
8.8+7.3
Control
EEV
EEV
EEV
Oil Type
FVC68D(PVE)
FVC68D(PVE)
FVC68D(PVE) (2.325±10)x2+2.325±70
L
2.325±10
2.325±10+2.325±70
Liquid Pipes
mm(inch)
9.52(3/8)
12.7(1/2)
15.88(5/8)
Gas Pipes
mm(inch)
22.2(7/8)
28.85(1 1/8)
34.9(1 3/8)
Oil Charge Amount Pipe Connctions
45
1
Type Charge
Refrigerant Oil
45 26.5 DC Inverter Scroll
Type Number of compressors
Refrigerant
53
51
51
Type
Inlet
PT32
PT40
PT32 + PT40
Outlet
PT32
PT40
PT32 + PT40
Drain Outlet
PT20
PT20
PT20
Number of outdoor unit
1
1
2
Number of connectable indoor units
16
32
49
Water Connection
Ratio of the connectable indoor units
50 ~ 130%
Longest piping length / Level difference
150m / 50m
* N : Heat Pump B : Heat Recovery Note 1. Capacities are based on following conditions: Cooling: -Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Water inlet temperature 30ºC(86ºF) Interconnecting piping length 7.5m Level difference of zero 2. Capacities are net capacities 3. Due to our policy of innovation some specification may be changed without prior notification 4. EEV : Electronic Expansion Valve
Heating:
-Indoor Temperature 20ºC(68ºF) DB -Water inlet temperature 20ºC(86ºF)
HP Model Name
Capacity Power Input COP
40
50
60
Combination Unit
BTO*40LA-X
BTO*50LA-X
BTO*60LA-X
Independent Unit
BTO*20LA-X
BTO*20LA-X
BTO*20LA-X
BTO*20LA-X
BTO*20LA-X
BTO*20LA-X
BTO*10LA-X
BTO*20LA-X
Cooling
kW
112.0
140.0
168.0
Heating
kW
126.0
157.5
189.0
Cooling
kW
22.4
28.0
33.6
Heating
kW
23.4
29.2
35.1
Cooling
5.00
5.00
5.00
Heating
5.38
5.39
5.38
3, 380~415, 50
3, 380~415, 50
3, 380~415, 50
(772x1,120x547)x2
(772x1,120x547)x3
(772x1,120x547)x3
238+238
238+238+170
238+238+238
Powersupply
ø, V, Hz
Dimensions (WxHxD)
mm
Net Weight
kg
Warm Gray
Color Noise Level Heat Exchanger
Stainless Steel Plate 45
45
45
kpa
43+43
26.5+43+43
43+43+43
LPM
192+192
192+192+96
192+192+192
4
DC Inverter Scroll / Constant Speed Scroll 5
6
R410A
R410A
R410A 8.8+8.8+8.8
Max. Pressure resistance kgf/cm2 Head loss Rated Water flow Compressor
Type Number of compressors
Refrigerant
Type
8.8+8.8
7.3+8.8+8.8
Control
EEV
EEV
EEV
Oil Type
FVC68D(PVE)
FVC68D(PVE)
FVC68D(PVE) (2.325±10)x3+(2.325±70)x3
Charge Refrigerant Oil
56
55
54
dBA Type
kg
(2.325±10)x2+(2.325±70)x2
(2.325±10)x3+(2.325±70)x2
Liquid Pipes
mm(inch)
19.05(3/4)
19.05(3/4)
19.05(3/4)
Gas Pipes
mm(inch)
41.3(1 5/8)
41.3(1 5/8)
41.3(1 5/8)
Inlet
PT40 + PT40
PT32+PT40+PT40
PT40+PT40+PT40
Outlet
PT40 + PT40
PT32+PT40+PT40
PT40+PT40+PT40
PT20
PT20
PT20
Number of outdoor unit
2
3
3
Number of connectable indoor units
64
64
64
Oil Charge Amount Pipe Connctions Water Connection
L
Drain Outlet
Ratio of the connectable indoor units
50 ~ 130%
Longest piping length / Level difference
150m / 50m
* N : Heat Pump B : Heat Recovery Note 1. Capacities are based on following conditions: Cooling: -Indoor Temperature 27ºC(80.6ºF) DB/19ºC(66.2ºF) WB -Water inlet temperature 30ºC(86ºF) Interconnecting piping length 7.5m Level difference of zero
Heating:
-Indoor Temperature 20ºC(68ºF) DB -Water inlet temperature 20ºC(86ºF)
2. Capacities are net capacities 3. Due to our policy of innovation some specification may be changed without prior notification 4. EEV : Electronic Expansion Valve
44 /45