Carling Technologies - Marine catalog

Page 1

MARINE

Switches, Circuit Protection & ELCI/GFCIs

CATALOG


Transforming Customer Needs into Customer Solutions Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! By working closely with a customer’s product team and understanding the requirements of the specific application, Carling’s product experts can tailor switching and circuit protection solutions to meet any customer’s needs—cost effectively. Since the company was founded in 1920, there are few products that Carling Technologies hasn’t turned “ON” and fewer industries that haven’t turned to Carling for solutions. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling now ranks among the world’s largest, privately owned manufacturers of hydraulic magnetic circuit breakers, thermal circuit breakers, electrical switches, electronic switches, miniature switches, power distribution centers, digital switching systems and electronic controls. Globally, there are over 2,000 employees working for Carling, providing solutions to customers’ application needs with innovation, value, and world-class service for both standard and custom products. Carling’s breadth and depth of standard product offerings gives customers literally millions of configuration choices to meet the demands of its Strategic Markets: Marine M ilitary Renewable Energy Telecom/Datacom Transportation

Additional markets served by Carling products include: Audio Visual, Commercial Food Equipment, Commercial HVAC, Floor Care, Generators, Industrial Control, Kitchen & Small Appliances, Security Systems, Test & Measurement equipment, among others. If the standard product does not meet the application requirements, the engineering team at Carling has the expertise to customize solutions faster and more creatively thanks in measure to over ninety years of experience as an innovative company that manufactures a diverse range of products. The Carling Sales, Service and Engineering teams work closely with the customer’s engineering team to advance a custom project from initial concept to final design and product release, respecting both quality and cost through out the process. With extensive field knowledge and resources available, Carling Technologies can ensure that the products created for the customer are of superior quality from the start, thus avoiding costly secondary operations or modifications. Carling’s commitment to excellence consistently delivers “Quality by Design,” the company mission. Carling has an extensive network of Sales Representatives and Distributors to assist with Carling products, or contact a Carling Technologies’ Technical Sales Representative to design innovative, cost-effective, quality engineered solutions that exceed the tough demands of today’s applications.

ii

www.carlingtech.com


Contents

Marine Switches, Circuit Breakers & ELCI/GFCIs With years of design and manufacturing experience, Carling Technologies is the market leader in marine application switches, circuit breakers and ELCIs. From small boats to luxury yachts, OEM design engineers trust our products not only for their style but also for their performance. Carling’s switches are widely used and the most recognizable switch brand in the industry with unmatched quality and aesthetics. Its circuit breakers and ELCIs are guaranteed to perform under extreme marine environments while keeping boats and boaters safe from electrical currents. By drawing upon over 90 years of design experience, Carling Technologies is also able to provide custom product solutions that are sure to meet the most stringent design requirements.

Product Selector Guide

page 2

Switches V-Series - Sealed Switch V-Series - Rotary Switch W-Series - Submersible Switch LT-Series - Toggle Switch P27-Series - Pushbutton Switch F & G-Series - Toggle Switch

5 9 11 13 13 14

Circuit Breakers M-Series 15 A-Series 17 B-Series 19 C-Series 21 E-Series 23 Thermal CMB-Series 25 CLB-Series 25 ELCIs/GFCIs PB-Series 26 PC-Series 28

Global Footprint Carling Technologies World Headquarters

Plainville, CT, USA

Maretron

Phoenix, AZ, USA

Carling Technologies European Headquarters Exeter, UK

Carling Technologies

Carling Technologies

Brownsville, TX, USA

Kowloon, Hong Kong

Carling Technologies

Carling Technologies

Matehuala, Mexico

Zhongshan, China

Carling Technologies Jupiter, FL, USA

www.carlingtech.com

1


Product Selector Guide - Switches

V-Series

V-Series Rotary

W-Series

LT-Series

NUMBER OF POLES

Single & Double

Single & Double

Single & Double

Single & Double

Single

Single

Single & Double

RATINGS

dry circuit to 15A, 24VDC 15A, 125VAC 10A, 250VAC 20A, 18VDC

dry circuit to 15A, 24VDC 15A, 125VAC 10A, 250VAC 20A, 18VDC

dry circuit to 10A, 24VDC

10A 250VAC 15A 125VAC 3/4HP 125-250VAC

3A 250VAC 6A 125VAC 3/4A 125V

10A 250VAC 15A 125VAC 3/4HP120-240VAC

10A 250VAC 15A 125VAC 3/4HP 125-250VAC

3A 250VAC 6A 125VAC 1/4HP 120-240VAC 12A , 250VAC

3A 250VAC 6A 125VAC 1/4HP 125-250VAC

P27-Series

F-Series

20A, 125VAC 1HP 120-240VAC

G-Series

12A 250VAC 17A 125VAC 1HP 250VAC 20A 250VAC 20A 125-277VAC 1 1/2HP 125VAC 2HP 125-250VAC 10A 250VAC 15A 125VAC 12(6)A 250VAC T85 1/4HP 125-250VAC

AVAILABLE AGENCY APPROVALS

UL, CSA, VDE, UL 1500

Pending

N/A

UL CSA

UL CSA

UL, CSA

UL, CSA, VDE

ACTUATOR TYPE

Contura 2-7: Bezel-less Rocker & Locking Rocker Contura 10-12: Rocker w/Bezel , Paddle & Locking Rocker

Rotary

Bezel-less Rocker, Paddle & Locking Rocker

Bat Toggle Translucent Paddle Clear Paddle

Nylon Concave Pushbutton

Metal Bat or Ball Style Toggles

Metal Bat or Nylon Paddle Styles

MOUNTING HOLE SPECIFICATIONS

1.45 x .83 [36.83mm x 21.08mm] Snap In

1.45 x .83 [36.83mm x 21.08mm] Snap In

1.45 x .83 [36.83mm x 21.08mm] Snap In

.500 diameter; 12.70mm diameter

.500 diameter; 12.70mm diameter

.500 diameter; through hole

.500 diameter; through hole

TERMINATION

Solder Lugs .250 tabs Wire Leads

Solder Lugs .250 tabs Wire Leads

.110 tabs

.250 QC Tabs .187 QC Tabs Solder Lugs Wire Leads Screw Terminals PC Terminals

Solder Lugs Wire Leads .250 QC Tabs

.250 Tabs Solder Lugs Wire Leads Screw Terminals .187 Tabs

.250 QC Tabs .187 QC Tabs Solder Lugs Wire Leads Screw Terminals PC Terminals

CIRCUIT CAPACITY

10 Terminals

10 Terminals

10 Terminals

8 Terminals

2 Terminals

3 Terminals

6 Terminals

SEALING

IP66/68 above panel

IP67 above panel

IP68 above and below panel, fully submersible

Bushing O-Ring

N/A

Optional Bushing O-Ring

Optional Bushing O-Ring

ILLUMINATION

Incandescent LED Neon

Incandescent LED Neon

LED

Incandescent Neon

N/A

N/A

N/A

ENVIRONMENTAL

MIL-STD 202F, 810C

MIL-STD 202F, 810C

MIL-STD 202F

N/A

N/A

N/A

N/A

2

www.carlingtech.com


Product Selector Guide - Circuit Breakers

M-SERIES

A-SERIES

B-SERIES

E-SERIES

C- SERIES

NUMBER OF POLES

1-2 poles

1-6 (handle); 1-3 (rocker)

1-6 (handle); 1-3 (rocker)

1-6 (handle); 1-3 (rocker)

1-6

ACTUATOR STYLE

Solid Color Angled Rocker Solid Color Flat Rocker Two Color Visi-Rocker Illuminated Angled Rocker Illuminated Flat Rocker Solid Color Paddle Solid Color Baton Solid Color Push-to-Reset Pushbutton Solid Color Push-Pull Pushbutton

Sealed Metal Toggle, Handle, Rocker, Paddle

Handle, Rocker

Handle, Rocker

Handle

AVAILABLE DELAYS

Instant, Short, Medium - AC/DC, Hi-Inrush

Instantaneous, Ultrashort, Short, Medium & Long, AC, DC, AC/DC High Inrush - Short, Medium & Long AC and DC

Instantaneous, Ultra-short, Short, Medium & Long, AC, DC, AC/DC High Inrush - Short, Medium & Long AC and DC

Instantaneous, Ultrashort, Short, Medium & Long, AC, DC, AC/DC High Inrush - Short, Medium & Long AC and DC

Instant, Short, Medium & Long - AC,DC, and AC/DC High Inrush Short, Medium & LongAC,DC, and AC/DC

MAXIMUM CURRENT & VOLTAGE RATINGS

0.02-15FLA, 32VDC, 125VAC, 1 pole 15.1-25GPA, 32VDC, 125VAC, 1-pole 0.02-15FLA, 65VDC, 250VAC, 2-pole 15.1-25GPA, 65VDC, 250VAC, 2-pole 0.02-12FLA, 250VAC, 1-pole 0.02-7.5GPA, 50VDC, 1-pole 0.02-30GPA, 65VDC, 80VDC, 1 pole

0.02 -30A@277VAC, 80VDC 31.0-50A@125/250VAC, 65VDC

0.02 -30A@277VAC, 80VDC 31.0-50A@125/250VAC, 65VDC

UL Listed 0.02-250A@80VDC 0.02-60A@125VDC 0.02-70A@120VAC 0.02-20A@240VAC UL Recognized 0.02-30A@480WYE /277VAC2-pole, 1Ø, 3-pole, 3Ø 0.02-50A@277VAC 0.02-100A@250VAC,80VDC 0.02-100A@120/240VAC, 65VDC

UL Listed 0.02-100A@240VAC, 65VDC, 125VDC UL Recognized 0.02-100A@277VAC, 160VDC, 1-pole 0.02-100A@600VAC, 2-pole 1Ø, 3 pole 3Ø 0.02-120A@125VDC, 1-pole

MAXIMUM INTERRUPTING CAPACITY

1,000A @ 65VDC, 2-pole 1,000A @ 32VDC, 1-pole 1,000A @ 250VAC, 2-pole 1,000A @ 125VAC, 1-pole 600A @ 80VDC

3000A@65 VDC, UL only 3500A@65 VDC, w/fuse backup 3000A@125/250VAC, UL only 5000A@277VAC, w/fuse backup

3000A@65 VDC, UL only 3500A@65 VDC, w/fuse backup 3000A@125/250VAC, UL only 5000A@277VAC, w/fuse backup

UL Listed 50000A@80VDC, 10,000A@120VAC, 5000A@125VDC, 240VAC UL Recognized 7500A@80VDC 3000A@125/250VAC, UL only 5000A@250VAC 5000A@480WYE/277V AC w/fuse backup

UL Listed 25000A@65VDC 5000A@125VDC& 240VAC UL Recognized 5000A@125VDC 5000A@600VAC, without fuse backup 10000A@600VAC, w/fuse backup

AUXILIARY SWITCH RATING

7A @ 250VAC 0.1A @ 125VAC (gold contacts) 7A (Res.) @ 28VDC 4A (Ind.) @ 28VDC 0.25A @ 80VDC

10.1A@125VAC 0.1A@125VAC (gold contacts) 0.5A@65VDC 0.1A@80VDC

10.1A@125VAC 0.1A@125VAC (gold contacts) 0.5A@65VDC 0.1A@80VDC

10.1A@250VAC 0.1A@125VAC (gold contacts) 0.5A@65VDC

10.1A@250VAC 1.0A@65VDC 0.1A@80VDC

AVAILABLE CIRCUITS

Series and Switch Only

Series, Shunt, Relay, Switch Only, Series w/Remote Shutdown, Relay & Shunt Trip Dual Coil

Series, Shunt, Relay, Switch Only, Series w/Remote Shutdown, Relay & Shunt Trip Dual Coil, Mid-Trip with Alarm Switch

Series, Shunt,Relay, Switch Only, Series w/Remote Shutdown, Relay & Shunt Trip Dual Coil, Mid-Trip with Alarm Switch

Series, Shunt, Relay, Switch Only, Series w/Remote Shutdown

TERMINAL OPTIONS

.250 QC Tabs 8-32 Screw w/ Upturned Lugs 8-32 Screw (Bus Type) Push in Stud Terminals

.250 Tab QC, 8-32 & 10-32 Screw (& metric), PCB

.250 Tab QC, 8-32 & 10-32 Screw (& metric), PCB

10-32 Stud, 1/4-20 Stud, 0-32 Screw/ saddle clamp, Clip Terminal, 1/4 & 7/16 Push-In

10-32 Stud, 1/4-20 Stud 0-32 Screw, 1/4-20 Screw, Box Wire Connector

MOUNTING METHOD

Snap-in Front Panel

Threaded inserts: Front Panel Snap-In

Threaded inserts: Front Panel Snap-In

Threaded inserts

Rear or Front Panel

OPERATING TEMPERATURE

-40° C to +85° C

-40° C to +85° C

-40° C to +85° C

-40° C to +85° C

-40° C to +85° C

UL, CSA, VDE, TUV(rocker), UL1500, UL489A

UL, CSA, VDE, TUV(rocker), UL1500, UL489, UL489A

UL, CSA, VDE, TUV, UL1500,UL489,UL489A

UL, CSA, VDE, UL1500, UL489

AGENCY APPROVALS UL recognized, CSA, VDE, TUV

www.carlingtech.com

3


Product Selector Guide - Thermal, ELCI/GFCIs

Thermal Circuit Breakers Max Interrupting Capacity

Number Of Poles

Actuator Style

Max Current & Voltage Rating

Single

Pushbutton

3 to 20A, 125-250VAC, 32VDC

2500A @ 32 VDC

Series Trip Manual Reset

.250 Tab w/QC .250 Tab w/QC with 90° bend

Front Panel Front Panel Snap-in

-10°C to 60°C

UL, CUL, CSA, TUV, CE, UL1500/ ISO8846 for ignition protection/marine

Single

Pushbutton

3 to 60A, 125-250VAC, 32VDC

2500A @ 32 VDC

Series Trip Manual Reset

.250 Tab w/QC .250 Tab w/QC with 90° bend Screw Terminal

Front Panel Front Panel Snap-in

-10°C to 60°C

UL, CUL, CSA, TUV, CE, UL1500/ ISO8846 for ignition protection/marine

Single

N/A

3 to 40A, 125-250VAC, 32VDC

2500A @ 32 VDC

Series Trip Auto Reset

.250” Tab, .250” Tab with 90° bend

Plug In

-10°C to 60°C

UL, CUL, TUV, UL1500 / ISO8846 for ignition protection / marine

CMB-Series

Available Circuits

Terminal Options

Mounting Method

Operating Temp

Agency Approvals

CLB-Series

CMBA/CLBA-Series

ELCI/GFCIs Number Of Poles

PB-Series

PC-Series

4

Actuator Style

Leakage Current Trip Level

Leakage Current Trip Time

Max Current & Voltage Ratings

Max Interrupting Capacity

Available Circuits

Terminal Options

Mounting Method

Operating Temp

Agency Approvals

1-3 poles, 3rd pole switched neutral

Handle, Rocker, Flat Rocker actuators

30mA & 6mA

For 30mA leakage trip: ≤ 22.2mA, shall not trip 30mA, shall trip within .10 seconds, complying with UL-1053 & ABYC E11. For 6mA leakage trip: ≤25ms, complying with UL-943.

0.10 - 30 amps @ 120/240 VAC

5,000 amps

Series Trip

.250 Quick Connect Tabs 8-32, 1032, M4,M5 screw with upturned lugs 8-32, 1032, M4,M5 screw, Bus Type

Front Panel

-35° C to +65° C

UL489, UL1077, UL1500

1-poles(1 CB + 1 GFCISensor Module), 120V 2-pole (2 CBs + 1 GFCI Sensor Module), 120/240V or 120V with Neutral Break. 3-pole 120/240V with Neutral Break (Sensor module has 2 pole width)

Handle, Rocker, Flat Rocker, Push-toreset actuators

30mA & 6mA

For 30mA leakage trip: ≤ 22.2mA, shall not trip 30mA, shall trip within .10 seconds, complying with UL-1053 & ABYC E11. For 6mA leakage trip: ≤25ms, complying with UL-943.

0.10 - 50 amps @ 120/240 VAC

5,000 amps

Series Trip

10-32 Threaded Stud

Front Panel

-35°C to +66°C

UL943 & CSA Approved, UL1053, UL1500

www.carlingtech.com


V-Series Contura Sealed Rocker Switches

V-Series Contura Switches The most popular switch and a staple in the marine industry, the V-Series switches offer countless unique options including choices for ratings, colors, illuminations and symbols. These switches feature removable actuators in a choice of actuator styles and colors, and are available in single or double pole configurations. The V-Series switches can be illuminated with either square, oval and/or bar shaped lenses.

WATCH PRODUCT VIDEO

CONTURA II & III

The Contura II & III actuators are constructed of thermoplastic polycarbonate and are offered with either a hard nylon overlay or a “soft-touch” elastomer overlay. These Contura models incorporate aesthetic designs on the top and bottom of the rocker featuring two rows of raised “bumps” on the Contura II and three “indented” lines on the Contura III.

CONTURA IV

The Contura IV’s “Shape to create a Shape” actuator supports the designer, by working with the curves, contours and advanced styling of the latest panel designs, flowing with these advanced curves and radii. This actuator style fits on the Contura II & III flush bracket/bezel.

CONTURA V

The symmetrically curved Contura V actuator provides the perfect complement to the Contura IV’s “Shape to create a Shape” design concept. It can be mounted in between two Contura IV’s, by itself, or in groups. This actuator style is available with all flush style mounting brackets.

www.carlingtech.com

5


V-Series Contura Sealed Rocker Switches

CONTURA VI

The Contura VI WAVE sealed rocker switches, when used in a row, create an uniquely appealing “wave� design on your panel. A variety of colors and finishes are available for both rocker and wave insert. Contura VI features bar and oval lenses.

CONTURA VII

A softened version of earlier Contura styles featuring gently curved corners and edges assuring compatibility with most any panel design. Intuitive feel is maximized by the use of 2 embossed circular pads located at opposite ends of the rocker. Any combination of Bar or Oval style lenses can be located in the pads providing a truly unique look, exclusive to Contura VII.

CONTURA XIII*

Contura XIII is a departure from any previous V-Series actuator styles. The familiar rectangular shape of Contura has now been tapered towards the center to create a unique figure 8-like shape which looks great as a single stand-alone switch, or when combined with 3 or more switches in a pod, the individual lines and curves serve to create additional looks and forms. Rocker top and bottom grip serrations provide tactile feel, while options for round or bar lenses and most any legend imprint are available to complete your panel design.

CONTURA XIV

Contura XIV represents a bold addition to existing V-Series actuator options. The traditional rectangular envelope has now taken on a whole new dimension through the addition of top and bottom indents coupled with a center channel, providing definitive tactile distinction between on and off positions. Indents are available in either a single or 2 stepped style, which both seamlessly incorporate optional bar or square lens options, as well as any of the hundreds of printed legends, which are offered.

*AVAILABLE IN 2015

6

www.carlingtech.com


V-Series Contura Sealed Rocker Switches

V-Series Switch DESIGN FEATURES INTERCHANGEABLE ACTUATORS

Panel redesign is a snap with our wide range of rocker styles. Achieve maximum design variety with minimum inventory. Simply swap rockers to create an entirely new look for your panel.

OPTIONAL PANEL SEAL Prevents water/dust ingress behind panel.

www.carlingtech.com

DUAL SEAL PROTECTION

Seals out water, dust, debris, and enables switch certification to IP66/IP68 for front panel components.

MULTIPLE LIGHTING OPTIONS In addition to incandescent lamps, our LED illumination is offered in a wide array of light intensities, colors, as well as dual level, tri-color, and flashing options.

CLEAN CONNECTIONS

Options for both eight and ten terminal base styles with AMP & Packard compatible connectors affords myriad circuit options while providing ease of assembly.

BRASS ROLLER PIN Robust mechanism eliminates the need for lubricants. Enables switch to withstand -40째C to +85째C temperatures.

SILVER PLATED BUTT CONTACT MECHANISM Providing 50K to 100K electrical cycles and a variety of different electrical ratings.

7


V–Series Contura Sealed Rocker Switches - General Specifications

Electrical

Contact Rating .4VA @ 24VDC (MAX) resistive 15 amps, 125VAC 10 amps, 250VAC 1/2 HP 125-250VAC 20 amps, 4-14VDC 15 amps, 15-28VDC 10A, 14VT 6A, 125VAC L Dielectric Strength 1500 Volts RMS Insulation Resistance 50 Megohms Initial Contact Resistance 10 milliohms max. @ 4VDC Life 50,000- 100,000 cycles circuit dependent Contacts Silver alloy, silver tin-oxide, fine silver Terminals Brass or copper/silver plate 1/4” (6.3mm) Quick Connect terminations standard. Solder lug, Wire Lead

Mechanical Endurance

150,000 cycles minimum circuit dependent

Lighted Seals Base Actuator Actuator, VP Lens

Incandescent - rated 10,000 hours Neon - rated 25,000 hours LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24VDC) Internal Optional external gasket panel seal Polyester blend rated to 125°C with a UL flammability rating of 94V0. Contura II, III, IV, V, VI Hard Surface: Basic actuator structure molded of thermoplastic polycarbonate with a hard Nylon 66 thermoplastic surface overlay. Soft Surface: Basic actuator structure molded of thermoplastic polycarbonate with an elastomer overlay. Contura X, XI, XII Nylon 66 Reinforced rated to 105°C Polycarbonate rated at 100°C

Physical

Actuator Travel (Angular Displacement) 2 position 3 positions

18° 9° from center

Mounting Specifications

.830[21.08] Panel Thickness Range Gaskets Acceptable Panel Thickness 0 .030 to .250 (.76mm to 6.35mm) TEST CUT IN 1.450[36.83] HOLE 1 .030 to .109 & .147 to .157 ACTUAL MATERIAL (.76 to 2.77mm & 3.73 to 3.98mm) Recommended: No gasket with panel SWITCH thickness of .032, .062, .093, .125,.187 or .250 MOUNTING HOLE

8

Agency Certifications Environmental

Environmental Sealed version: IP68, in accordance with IEC 60529, BS 5490, DIN 40050 & NFC 20 010. This rating applies to front panel components of the actual switch only, and signifies protection against dust and the prolonged effects of immersion under pressure. The standard test for immersion under pressure requires submersion under one meter of water for 30 minutes. The V-Series switch has exceeded these parameters, having been actuated and illuminated during submersion. Corrosion Flowing Mixed Gas (FMG) Class III 3 year accelerated exposure per ASTM B-827, B-845 Silver and gold contacts Operating Temp. -40°C to + 85°C Vibration 1 Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G’s 10-500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test and pre and post test contact resistance. Vibration 2 Resonance search 24-50 Hz 0.40 DA 50-2000 ±10 G’s peak Results Horizontal Axis 3-5 G’s max. Random 24 Hz 0.06 PSD-Gsq/Hz 60 Hz 0.50 100 Hz 0.50 200 Hz 0.025 2000 Hz 0.025 No loss of circuit during test; <10μ seconds chatter. Shock Per Mil-Std 202F, Method 213B, Test Condition K @ 30G’s. Tested with VCH connector. Test criteria - No loss of circuit during test, pre and post test contact resistance. Salt Spray Per Mil-Std 202F, Method 101D, Test Condition A, 48 Hrs. Sealed version only. Dust Per Mil-Std 810C, Method 510.2 Air Velocity 300 ±200 Feet/Min, Test Duration 16 Hrs. Thermal Shock Per Mil-Std 202F, Method 107F, Test Cond. A, -55°C to 85°C. Test criteria pre and post test contact resistance Moisture Resistance Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance Ignition Protection All Contura switches with sealed construction meet the requirements of UL1500/ISO8846 for ignition protection, in addition to conformance with EC directive 94/25/EC for marine products.

www.carlingtech.com


V-Series Contura Rotary Switch

V-Series Contura Rotary Switch

The V-Series Contura Rotary Switch was designed for maximum performance and reliability leveraging the features of the widely popular V-series Contura Rocker Switches. Available in maintained and momentary circuit options, the V-Series Rotary features a sturdy knob construction, up to three separate LEDs, and fits in an industry standard panel opening. Internally, the V-Series Contura Rotary uses a patented mechanism that translates rotary to linear motion. This allows for common switch functionality and terminal connections with the V-Series rocker version and requires no harness change. A secondary CAM, which helps drive the mechanism, provides definitive detent positions and prevents the switch from stopping between positions, while improving tactile feel. The V-Series Rotary also features an innovative PC board that supports the LED and surface mount resistors; and IP67 sealing protection above panel by utilizing LED and actuator stem seals. Together, these features make the V-Series Contura Rotary switch the best choice available in the market today.

DESIGN FEATURES OPTIONAL PANEL SEAL Prevents water/dust ingress behind panel

LEDS Up to three separate LEDs

www.carlingtech.com

SEALS LED and stem seals provide IP67 protection above panel

ROTARY & LINEAR ACTUATOR Patented mechanism that translates rotary to linear motion

PC BOARD Supports LEDs and surface mount resistors

TERMINALS Same pinout as V-Series Rocker Switches, requiring no harness change

SECONDARY CAM Provides definitive detent positions with ball & spring located in rotary actuator

9


V-Series Contura Rotary Switch

Electrical

Mechanical

Rating

Voltage

Max Current Resistive

2 Position Maintain

12

20

2 Position Momentary

12

20

3 Position All

12

20

2 Position Maintain

24

15

2 Position Momentary

24

15

3 Position All

24

15

Circuit

Dielectric Strength 1500 Volts RMS Insulation Resistance 50 Megohms Initial Contact Resistance 10 Milli Ohm max @ 4VDC Life 50,000 Cycles Two Position 25,000 Cycles Two Position Momentary and All Three position Terminals 0.250” (6.3mm) Quick Connect

Physical

Function Circuits Single and Double Pole Single Throw, SPST, DPST Single and Double Pole Double Throw, SPDT, DPDT Operation Two and Three Position Maintained and Momentary Knob Rotation Two Position 60 Degrees Three Position 30 Degrees from Center Illumination LED; Red, Green, Amber, Yellow, White, Blue Seals LED O-ring(s) – Silicone, Bezel gasket – Neoprene, Knob seal - NBR Flammability Exceeds FVMSS 302 Requirements, Exterior Components, UL 94 V-2 or Better Interior Components, UL 94 HB or Better Base Polyester, PBT Bracket Nylon 66, PA Knob Polybutylene Terephthalate, PBT 6.5%GF Lens Polycarbonate, PC Connector Nylon 66, PA Mounting Front Panel Snap In, 1.450” (36.83mm) X 0.830” (21.08mm) Panel Thickness, 0.030” – 0.187” (0.76 – 4.75mm)

10

Mechanical Life Knob Impact

100,000 Cycles Maintained Circuits 50,000 Cycles Momentary Circuits 50 Gram weight dropped from a height of 18 inches on Top & Sides

Environmental Sealing Dust Corrosion Chemical Splash Salt Spray Vibration Random Vibration Sinusoidal Shock Handling Shock Thermal Shock Moisture Resistance Thermal Cycling Ignition Protection UV Protection ESD

IP67, in accordance with IEC 60529, BS 5490, DIN 40050 & NFC 20 010. This rating applies to front panel components of the actual switch only, and signifies protection against dust and the prolonged effects of immersion under pressure. Mil STD 810, Method 510.2 Air Velocity 300 Ft/Min Duration 16Hr IEC 68-2-60 Mixed Flowing Gas (MFG) 14 Days Gasoline, Diesel, Motor Oil, Brake Fluid, Ammonia, Armour All Mil STD 202G, Method 101, Test Condition A 96 Hr Mil STD 202G, Method 214 test Condition C 10G’s RMS Mil STD 202G, Method 204D, Test Condition A 0.06DA or 10G’s 10-500Hz MIL-STD 202G, Method 213B Test Condition K, 30G’s 1 Meter Drop onto Hard Surface MIL-STD 202G, Method 107G Test Condition A -55 C to 85 C MIL-STD 202G, Method 106F 10, 25 C to 65 C Cycles 95% RH 25 Cycles -40 C to 85 C ISO 8846 with EC Directive 94/25/EC for Marine Products 300 hr Xenon Arc, 1.4W/m2 wavelength 420 nm Human Static Discharge, +/- 15KV applied during normal operation Shipping/Handling, frequency range 200-2000 MHz applied voltage is +8KV to +15KV and -8KV to -15KV 3 discharge cycles

www.carlingtech.com


W-Series Fully Submersible Rocker Switch

W-Series Fully Submersible Rocker Switch

Carling Technologies set the standard for performance, reliability and aesthetics with the widely successful, often imitated, but never duplicated, V-Series rocker switches. Building further upon that platform, Carling has once again raised the bar with the fully submersible W-Series. The W-Series traditional appearance features complete IP68 protection, even below the panel, where the critical connection is made from your wiring harness. When used in conjunction with the integrated connector, the totally submersible W-Series provides a seal for up to ten individual wires, assuring compatibility with even the most complex circuitry. The W-Series also offers a wide variety of accoutrements including endless illumination options featuring dual level and multicolor LEDs, progressive and hazard warning circuits, ratings up to 10A 24V, choice of paddle, rocker, locking or laser etched actuators, hundreds of standard legend choices and the electrical performance and reliability that is the hallmark of Carling Technologies products.

DESIGN FEATURES ILLUMINATION Choice of highly reliable SMT LED or incandescent lighting with 21 dependent or independent circuit options.

BODY One piece polyester 94V0 seamless body acts as an umbrella to protect critical internal components.

www.carlingtech.com

TRI-SEAL DESIGN Sealing at actuator, an insert molded neoprene base seal, along with wire lead seals, assures water tight, fully submersible protection.

ROLLER PIN Proven reliable mechanism is lubricant free and allows for 100k electrical and 250k mechanical cycles, and withstands extreme temperatures from -40ËšC to +85ËšC.

INTEGRATED CONNECTOR Accommodates Tyco/Amp .110 junior power timer contacts with twin locking tabs to provide a safe, secure, sealed connection.

11


W-Series Fully Submersible Rocker Switch

Electrical

Environmental

Contact Rating Dielectric Strength Insulation Resistance Initial Contact Resistance Life Contacts Terminals Quick Voltage Overcurrent

.4VA @ 24VDC 10 amps, 3-24VDC 1500 Volts RMS 50 Megaohms 10 milliohms max. @ 4 VDC 100,000 cycles Silver tin-oxide, 88/12 Copper with silver or gold plating. Connect terminations. 3-24 VDC 15A for 50 cycles

Mechanical Endurance

250,000 cycles minimum

Physical Lighted LED - rated 100,000 hours 1/2 life (LED is internally ballasted for voltages to 24 VDC) Seals Neoprene Base Polyester blend rated to 125C with a UL flammability rating of 94V0. Actuator Basic actuator structure molded of thermoplastic polycarbonate with a hard Nylon 66 thermoplastic surface overlay. Lens Polycarbonate rated at 100°C Function 2 & 3 Position Rocker Style Operation Maintained & Momentary Base PA 6/6 30GF (glass filled) Actuator PA 6/6 13GF Bracket PBT 10GF Connector PBT 10GF, polarized

Actuator Travel (Angular Displacement)

Environmental IP68, Fully sealed Corrosion/ Flowing Mixed Gas (FMG) Chemical Splash Class III 3 year accelerated exposure per ASTM B-827, B-845 Operating Temperature -40°C to +85°C, 22 cycles, 300 hours Vibration 1 Per Mil-Std 202F, Method 204D Test Condition A 0.06 DA or 10G’s 10-500 Hz. Vibration 2 Resonance search 24-50 Hz 0.40 DA 50-2000 ±10 G’s peak Results Horizontal Axis 3-5 G’s max. Random 24 Hz 0.06 PSD-Gsq/Hz 60 Hz 0.50 100 Hz 0.50 200 Hz 0.025 2000 Hz 0.025 Handling/Drop One meter onto concrete floor Salt Spray Per Mil-Std 202F, Method 101D, Test Condition A, 48 Hrs. Dust IP6X Thermal Shock Per Mil-Std 202F, Method 107F, Test Condition A, -55°C to 85°C. Test criteria - pre and post test contact resistance Moisture Resistance/ Humidity Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact resistance

Mounting Specifications Panel Thickness Range .032 to [25.40] .125 1.000

12° For optimum panel fit, the following panel thicknesses are suggested: .032, .062, .093, .125

.830[21.08] 1.962 [49.83]

24° full throw

1.724 [43.78]

SWITCH SHOWN WITH CONNECTOR INSTALLED

12°

1.962 [49.83]

SWITCH SHOWN WITH CONNECTOR INSTALLED

.418 [10.62]

1.707 [43.36]

2.162 [54.91]

.418 [10.62]

1.707 [43.36]

2.162 [54.91]

1.450[36.83] 1.000 [25.40]

TEST CUT HOLE IN ACTUAL MATERIAL

.031 [.79]

.465 [11.81]

.110 [2.79]

1.178 [29.93] .714 [18.14]

.465 [11.81]

.110 [2.79]

1.664 [42.27]

SWITCH MOUNTING HOLE KEYING FEATURE

.031 [.79]

1.724 [43.78]

1.080

[27.43] 1.664 [42.27]

WCH CONNECTOR (190-31214-001)

1.200

[30.48]

Notes: KEYING FEATURE 1.178.110 [29.93] Junior Power Timer, female contacts, and wire seals. For 14WCH connector is intended for use with Tyco/Amp 16 awg wire, specify Tyco/Amp P/N 927766-3. For 16-20 awg wire, specify Tyco/Amp P/N 927770-3. Tyco/Amp cable .714 [18.14] 1.080wire) is required for each individual wire lead, and seal P/N 828904-1 (20-18 awg wire) or P/N 828905-1 (16-14 awg [27.43] Tyco/Amp cable plug, P/N 828922-1, is required to seal each unused connector opening. Consult Tyco/Amp for the cable seal recommended WCH CONNECTOR for your specific wire gauge and thickness. (190-31214-001)

12

1.200

[30.48]

www.carlingtech.com


LT-Series Toggle Switch & P27-Series Pushbutton Switch

LT-Series Toggle Switch

The LT-Series illuminated toggle switches feature a three-color lighting sequence from a single lamp. These lighted toggles contain neoprene bushing seals for dust and moisture protection and provide a simple way to dress-up most any Marine or Transportation industry panel. A variety of circuits and terminations are available. Dielectric Strength 1000V-live to dead metal parts Electrical Life 50,000 cycles- maintained 25,000 cycles- momentary Mechanical Life 100,000 cycles Operating Temperature 32°F to 185°F (0°C to 85°C)

P27-Series Pushbutton Switch The P27-Series pushbutton switches are single pole, AC rated switches suitable for general purpose applications with a shallow back panel. These switches are momentary action with a medium actuation force (26 oz. typical). The P27-Series switch is equipped with a slow-make, slow-break contact mechanism, rated at 6 amps with a nylon concave pushbutton. Dielectric Strength UL/CSA: 1000V - live to dead metal parts Electrical Life 25,000 cycles Mechanical Life 100,000 cycles Operating Temperature 32°F to 85°F (0°C to +85°C)

www.carlingtech.com

13


F & G-Series Toggle Switches

F & G-Series Toggle Switches With a storied history in the marine market, these general purpose toggle switches are available with options tailored to meet most any need. Ratings to 20A 277VAC, various actuator, bushing, termination, and circuit choices allow this versatile switch to easily integrate into a variety of different applications.

F-Series Single Pole Toggle Switch

.075[1.91] DIA

.125[3.18] DIA .075[1.91] DIA

.125[3.18] DIA 15/32-32UNS-2A THREAD 15/32-32UNS-2A THREAD

.330[8.38]

.687[17.44]

.465[11.81]

.465[11.81]

1.134[28.80]

.187 TAB (Q.C.)

.500[12.70] DIA

WIRE LEAD .500[12.70] DIA

.500[12.70] DIA

.376[9.55]

WIRE LEAD

.500[12.70] DIA

.038[9.65]

.500[12.70] DIA .125[3.17] DIA WITH LOCKING RING

WITH KEYWAY

.500[12.70]

SCREW (ASSEMBLED) .062[1.57]

.634[16.10]

SCREW (ASSEMBLED) .062[1.57]

.038[9.65] MOUNTING HOLE

.286[7.26]

MOUNTING HOLE

.187 TAB (Q.C.)

6.000[152.40]

.141[3.58]

.370[9.39]

.500[12.70]

.286[7.26] 1.134[28.80]

.634[16.10]

.187[4.74]

.250 TAB (Q.C.)

#6-32NC-2 THREAD 6.000[152.40]

.141[3.58]

.394[10.00]

Dielectric Strength UL/CSA: TERMINAL TYPE 1000V - live to dead metal parts Electrical Life 50,000 cycles- maintained 25,000 cycles- momentary Mechanical Life 100,000 cycles Operating Temperature 0°F to 150°F (-17.8°C to +65.6°C)

SOLDER LUG

TERMINAL TYPE

.055[1.40] DIA

.437[11.09] .250[6.35]

.187[4.74]

.687[17.44] .187[4.74]

.370[9.39] .348[8.84]

.348[8.84]

.330[8.38]

.394[10.00]

.038[.965] DP .250 TAB (Q.C.)

SOLDER LUG

.670[17.02] #6-32NC-2 THREAD

.670[17.02]

.437[11.09]

KEYWAY .072[1.82] .250[6.35] X

.187[4.74] KEYWAY .072[1.82] X .038[.965] DP

.055[1.40] DIA

WITH KEYWAY

.376[9.55]

.500[12.70] DIA .125[3.17] DIA WITH LOCKING RING

G-Series Toggle Switch

.687[17.44] .687[17.44]

15/32-32UNS-2A THREAD

.465[11.81]

.778[19.76] .465[11.81]

.778[19.76]

1.308[33.22]

.422[10.72]

.778[19.76]

KEYWAY .072[1.82] X .038[.965] DP

.778[19.76]

.490[22.86]

.075[1.905]

.075[1.905]

.750[19.05] 1.308[33.22]

.422[10.72]

.075[1.91] DIA

.125[3.18] DIA

15/32-32UNS-2A THREAD

KEYWAY .072[1.82] X .038[.965] DP

.055[1.40] DIA

Dielectric Strength .075[1.91] DIA .055[1.40] DIA .394[10.00] .437[11.09] DIA- live to dead UL/CSA:.125[3.18] 1000V metal parts & opposite .330[8.38] polarity VDE: 4000V - live to dead metal parts; 1250V .394[10.00] .437[11.09] .187[4.74] .187[4.74] .250[6.35] opposite polarity &.330[8.38] across open contacts SOLDER LUG .250 TAB (Q.C.) .187 TAB (Q.C.) .187[4.74] .187[4.74] .250[6.35] Electrical Life SOLDER LUG .250 TAB (Q.C.) .187 TAB (Q.C.) 50,000 cyclesmaintained TERMINAL TYPE 25,000 cycles- momentaryTERMINAL TYPE #6-32NC-2 .187[4.75] 6.000[152.40] Mechanical Life THREAD #6-32NC-2 .141[3.58] .750[19.05] .187[4.75] 6.000[152.40] 100,000THREAD cycles .141[3.58] .370[9.39] .187[4.75] Operating Temperature .370[9.39] .500[12.70] .187[4.75] .500[12.70] 32°F to 185°F (0° to 85°C) .350[8.89] .286[7.26] .286[7.26]

.350[8.89]

SCREW SCREW PRINTED PRINTED WIREWIRE LEAD LEAD (ASSEMBLED) CIRCUIT (ASSEMBLED) CIRCUIT .062[1.57] .376[9.55] .062[1.57] .376[9.55] .500[12.70] DIA .500[12.70] DIA .500[12.70] DIA .500[12.70] DIA

.490[22.86]

.750[19.05]

IEC APPROVED CONSTRUCTION

IEC APPROVED CONSTRUCTION

.750[19.05]

.038[9.65]

.038[9.65]

MOUNTING HOLE

MOUNTING HOLE

WITH KEYWAY

WITH KEYWAY

.500[12.70] DIA .125[3.17] DIA .125[3.17] DIA WITH LOCKING RING

.500[12.70] DIA

WITH LOCKING RING

*Manufacturer reserves the right to change product specification without prior notice.

14

www.carlingtech.com


M-Series Circuit Breaker

M-Series Circuit Breaker The low cost M-Series utilizes the hydraulic magnetic principle which provides accurate and reliable circuit protection even when exposed to extremely hot and/or cold application environments. Available in a choice of rocker actuator styles and colors, push button, push-pull, paddle, and baton style handle actuators, the Visi-Rocker® two-color actuators, as well as non-illuminated or illuminated rocker versions with LED or neon bulbs. The exclusive Rockerguard® bezel helps prevent inadvertent actuation. “Wiping” contact design insures long term reliability. Various styling options allow design flexibility.

M-SERIES HANDLE FORM & FIT DRAWING

www.carlingtech.com

M-SERIES PUSHBUTTON FORM & FIT DRAWING

15


M-Series Circuit Breaker

Mechanical

Electrical

Maximum Voltage 125/250 VAC 50/60 Hz, 80 VDC (See Rating Tables.) Current Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00 thru 15.0 in 1 amp increments, 18.0, 20.0, 25.0, 30.0. Other ratings available - see Ordering Scheme. Auxiliary Switch Rating SPDT; 7A 250VAC, 7A (Res) 28VDC, 4A (Ind.) 28VDC, 0.25A 80VDC (Res) (silver contacts), 0.1A 125VAC (gold contacts). Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA 1500V, 50/60 Hz for one minute between all electrically isolated terminals. M-Series Circuit Breakers comply with the 8mm spacing and 3750 V 50/60Hz dielectric requirements from hazardous voltage to operator accessible surfaces, per Publications IEC 380, 435, 950, EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker)

CURRENT (AMPS)

TOLERANCE (%)

0.10 - 20.0 20.1 - 50.0

±25 ±35

Pulse Tolerance Curves

Endurance 10,000 ON-OFF operations @ 6 per minute with rated Current and Voltage. Trip Free All M-Series Circuit Breakers will trip on overload, even when actuator is forcibly held in the ON position. Trip Indication The actuator moves positively to the OFF position when an overload causes the circuit breaker to trip.

Physical

Number of Poles Internal Circuit Configs. Weight Standard Colors

1 or 2 Series with or without Auxiliary Switch. Switch Only with or without Auxiliary Switch. Approximately 30 grams/pole (Approximately 1.07 ounces/pole) See Ordering Scheme.a

Environmental

Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Cond. I. Instantaneous curves tested at 80% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous curves tested at 80% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80 98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C Chemical Resistance Only the outside surfaces of the case and the handles may be cleaned with detergents or alcohol. Organic (hydrocarbon based) solvents are not recommended because they attack plastics. Caution should be taken when solvents are used to clean and remove flux from terminals. Lubricants should not be introduced into the handle/ bushing openings

*Manufacturer reserves the right to change product specification without prior notice.

16

www.carlingtech.com


A-Series Circuit Breaker

A-Series Circuit Breaker Compact in size and well known for its proven reliability, the A-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. When aesthetics demand a clean contemporary and functional design, the visi-rocker two-color actuator can be specified. A rocker guard and push-to-reset bezel helps prevent inadvertent actuation. A specially constructed version is now available for applications requiring CE markings. It can be configured as 1-6 poles (handle), 1-3 poles (rocker), 0.02 – 50 amps, up to 277 VAC or 80 VDC, with a choice of time delays, terminals and actuator colors.

www.carlingtech.com

17


A-Series Circuit Breaker

Electrical

Mechanical

Maximum Voltage 277VAC 50/60 Hz, 80VDC Current Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0, 50.0. Other ratings available - consult ordering scheme. Standard Voltage Coils DC-6V, 12V; AC-120V, Other ratings available, consult ordering scheme. Auxiliary Switch Rating SPDT; 10.1 A - 250VAC, 1.0 A-65VDC/0.5 A - 80 VDC, 0.1A - 125VAC (with gold contacts). Insulation Resistance Minimum: 100 Megohms at 500 VDC Dielectric Strength UL, CSA - 1500V 60 Hz for one minute between all electrically isolated terminals. A-Series rocker circuit breakers comply with the 8mm spacing & 3750V dielectric requirements from hazardous voltage to operator accessible surfaces per EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker.

Endurance Trip Free Trip Indication

RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker)

10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. All A-Series Circuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. When mid-trip handle is specified, the handle moves to the mid position on electrical trip of the circuit breaker. When mid-trip handle with alarm switch is specified, the handle moves to the mid position & the alarm switch actuates when the circuit breaker is electrically tripped.

Physical Number of Poles 1 - 6 Poles (handle) and 1-3 poles (rocker) at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps. Internal Circuit Config. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only with or without auxiliary switch. Weight Approximately 65 grams/pole. (Approximately 2.32 ounces/pole) Standard Colors Housing - Black; Actuator- See Ordering Scheme.

Environmental

Pulse Tolerance Curves

Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D; ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH.56 days @ +85°C, 85% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C

*Manufacturer reserves the right to change product specification without prior notice.

18

www.carlingtech.com


B-Series Circuit Breaker

B-Series Circuit Breaker Designed specifically for world market applications, the B-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. It can be configured as 1-6 poles, 0.02 - 50 amps, up to 277 VAC or 80 VDC, with choice of time delays, terminals and actuator colors.

www.carlingtech.com

19


B-Series Circuit Breaker

Electrical

Mechanical

Maximum Voltage 277VAC 50/60 Hz, 80VDC Current Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0 and 50.0 amps. Other ratings available, see ordering scheme. Standard Voltage Coils DC - 6V, 12V; AC - 120V, other ratings available, see ordering scheme. Auxiliary Switch Rating SPDT; 10.1 AMPS - 250VAC,1.0A 65 VDC or 0.5A 80 VDC, 0.1 Amps - 125VAC (with gold contacts). VDE-1.0 Amp - 125VAC. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA-1500 V 50/60 Hz for one minute between all electrically isolated terminals. B-Series circuit breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker.

Endurance 10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage. Trip Free All B-Series Circuit Breakers will trip on overload, even when Handle is forcibly held in the ON position. Trip Indication The operating Handle moves positively to the OFF position when an overload causes the breaker to trip.

RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker)

Pulse Tolerance Curves

Physical

Number of Poles 1 - 6 poles at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps. Internal Circuit Config. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only (with or without auxiliary switch). Weight Approximately 65 grams/pole. (Approximately 2.32 ounces/pole.) Standard Colors Housing- Black; Actuator - See Ordering Scheme.

Environmental

Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C

*Manufacturer reserves the right to change product specification without prior notice.

20

www.carlingtech.com


C-Series Circuit Breaker

C-Series Circuit Breaker The C-Series circuit breaker was designed for applications that require higher amperage and voltage handling capabilities in a compact design. It is available with American Standard or Metric Threaded Stud terminals, or Saddle Clamp screw terminals. Additional options include mid-trip handle style actuator, solid color rocker actuators and visi-rocker two color actuators. The visi-rocker option can be specified to indicate either the ON or TRIPPED/OFF mode while the optional rocker guard and push-to-reset bezel can help prevent inadvertent actuation. The C-Series UL489 breakers employ a unique arc chute design which results in obtaining higher interrupting capacities, up to 50,000 amps. Thermoset glass filled polyester half shell construction increases mechanical & electrical strength and the Wiping Contacts – Mechanical linkage with two-step actuation cleans contacts, provides high, positive contact pressure & longer contact life; It can be configured as 1-6 poles, 0.02 - 100 amps, up to 480 VAC or 80 VDC, UL489 up to 240 VAC or 125 VDC, with choice of time delays and actuator colors.

www.carlingtech.com

21


C-Series Circuit Breaker

Mechanical

Electrical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz (see Table A.) UL489: AC,240 VAC. (See Table D), 50/60 Hz, 125 VDC Current Rating Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 25.0, 30.0, 35.0, 40.0, 50.0, 60.0, 70.0, 80.0, 90.0 and 100 amps. Other ratings available, see Ordering Scheme. Standard Voltage Coils DC - 6V, 12V; AC - 120V; other ratings available, see Ordering Scheme. Auxiliary Switch Rating SPDT; 10.1 amps-250VAC, DC Aux. Switch 1.0A, 65 VDC. 0.5A, 80VDC,1/4 HP, 125VAC,VDE & TUV 1.0 125 VAC. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one minute between all electrically isolated terminals. C-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal based on Series Trip Circuit Breaker. RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker )

1000

CURRENT (AMPS)

TOLERANCE (%)

0.10 - 5.0

15%

20.1 - 100.0

35%

100

5.1 - 20.0

10

O H M S

1

0.1

60 Hz 1/2 Cycle Inrush Pulse Tolerance Time Delay Curves 42, 44 & 46 (50 Amps Max.)

Multiple of Rated Current

Ir

25x

0.01

Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.)

12x

0.001 0.01

1

0.1

10

25%

100

t

AMPERE RATING

4.165

8.33

16.67

Pulse Tolerance Curves TOLERANCE (%) 15% 25% 35%

25x

Ir

1

Multiple of Rated Current

FIGURE Time Delay Curves 42, 44 & 46 (50 Amps Max.)

Multiple of Rated Current

Ir

CURRENT (AMPS)

0.100 - 5.0

- 20.0 60 Hz 1/25.1 Cycle - 100 Inrush Pulse20.1 Tolerance

Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.)

12x

Time Delay Curves 42, 44 & 46 (50 Amps Max.) Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.)

10x

t t 4.165

Ir

Multiple of Rated Current

50 Hz 1/2 Cycle Inrush Pulse Tolerance

22x

8.33

5.0

16.67

10.0

50 Hz 1/2 Cycle Inrush Pulse Tolerance

Time Delay Curves 42, 44 & 46 (50 Amps Max.)

22x

Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.)

10x

20.0

Time in Milliseconds

Endurance 10,000 ON-OFF operations @ 6 per minute; with rated current & voltage. Trip Free All C-Series circuit breakers will trip on overload, even when actuator is forcibly held in the ON position. Trip Indication The operating actuator moves positively to the OFF position when an overload causes the breaker to trip. With mid-trip, handle moves to the mid position on electrical trip of the circuit breaker. With mid trip handle with alarm switch, handle moves to the mid position and the alarm switch actuates when the circuit breaker is electrically tripped.

Physical

Number of Poles Internal Circuit Config. Weight Standard Colors

1-6 poles ≤ 50A; 1-4 poles @ 5170A; 1-2 poles 71-100A. UL489 Handle: 1 pole ≤ 100A, 2 pole ≤ 50A; Rocker: 1 pole ≤ 100A. Series (with or without auxiliary switch, mid trip & mid trip with alarm switch) Shunt & Relay with current or voltage trip coils, Dual Coil, Switch Only (with or without aux. switch). UL489: Series (with or without auxiliary switch, mid-trip & midtrip with alarm switch). Approx.112 grams/pole ( 3.95 oz). Housing: Black

Environmental

Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows:

Shock Withstands 100 Gs, 6ms sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultrashort curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz & 10 Gs 55-500 Hz, @ rated current per Method 204C, Test Cond. A. Instantaneous & ultrashort curves tested @ 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ +25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40°C to +85°C

t 5.0

10.0

20.0

Time in right to change product specification without prior notice. *Manufacturer reserves the Milliseconds

22

www.carlingtech.com


E-Series Circuit Breaker

E-Series Circuit Breaker

Ideally suited for higher amperage applications, the E-Series is available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire or a pressure plate connector for stranded wire. Consult factory for an optional power selector device. The E-Series is UL Listed and CSA Certified for Branch Circuit protection which does not require a fuse backup. It is also UL Recognized and CSA Certified as a Supplementary Protector and as a Manual Motor Controller. The E-Series can be configured as 1-6 poles, .1 - 100 amps, up to 600 VAC or 125 VDC, with choice of time delays and actuator colors. ELECTRICAL

Table A: Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations & performance capabilities as a Molded Case Circuit Breaker.

www.carlingtech.com

23


E-Series Circuit Breaker

Mechanical

Electrical

Maximum Voltage 600VAC 50/60 Hz, 125VDC (See Table A) Current Ratings Standard current coils: 0.100, 0.250, 0.500, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 50.0, 60.0, 70.0 & 100 Amp. Auxiliary Switch Rating SPDT; 10.1A 250VAC, 1.0A 65VDC; 0.5A 80VDC, 0.1A 125VAC (with gold contacts). Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 2200 V 50/60 Hz for one minute between all electrically isolated terminals. E-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker.

Endurance 10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage. Trip Free All E-Series Circuit Breakers will trip on overload, even when Handle is forcibly held in the ON position. Trip Indication The operating Handle moves positively to the OFF position when an overload causes the breaker to trip.

Physical

Number of Poles Mounting Connectors, Box Type Internal Circuit Configuration Weight Standard Colors

1-6 A 3” minimum spacing must be provided between the circuit breaker arc venting area on back connected E-Series circuit breakers and grounded obstructions. E-Series circuit breakers must be mounted on a vertical surface. Front connected E-Series circuit breakers are supplied with box type pressure connectors that accept copper or aluminum conductors as follows: 1/0-14 Copper, 1/0-12 Aluminum. Series and Switch Only, (with or without auxiliary switch). Shunt with current coils. Approximately 252 grams/pole (Approximately 9 ounces/pole) Housing-Black; Actuator - See Ordering Scheme.

Environmental Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Pulse Tolerance Curves

Time Delay Curves 62, 64 & 66 (100 Amps Max.) Time Delay Curves 22, 24 & 26 (100 Amps Max.)

Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C

*Manufacturer reserves the right to change product specification without prior notice.

24

www.carlingtech.com


CMB & CLB Thermal Circuit Breakers

CMB-Series Thermal Circuit Breaker Rating: 3 to 20A, 125-250VAC, 32VDC Approvals: UL, CUL, CSA, TUV, CE UL1500/ISO8846 for ignition protection/marine Dielectric Strength: 2500 VAC/ 1 minute

Interrupting capacity: 2500 amps Insulation Resistance: 100M ohms Operating Temperature: -10째C to 60째C Voltage drop: < 0.25 V

CLB-Series Thermal Circuit Breaker Rating: 3 to 60A, 125-250VAC, 32VDC Approvals: UL, CUL, CSA, TUV, CE UL1500/ISO8846 for ignition protection/marine Dielectric Strength: 2500 VAC/ 1 minute

www.carlingtech.com

Interrupting capacity: 2500 amps Insulation Resistance: 100M ohms Operating Temperature: -10째C to 60째C Voltage drop: < 0.25 V

25


PB-Series ELCI/GFCI

PB-Series ELCI/GFCI The PB-Series, an AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of an ELCI with the familiar overcurrent tripping characteristics of a normal circuit breaker. The PB-Series increases safety around boats and marinas by detecting lower level ground faults, which do not trip ordinary circuit breakers, but can lead to fires and shock hazards. A specially designed panel seal that provides maximum environmental protection is also available. PB-SERIES SHOWN WITH SEAL

Handle Style Panel Seal

Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance Âą.020 [.51] unless otherwise specified.

26

www.carlingtech.com


PB-Series ELCI/GFCI

Electrical Tables

Mechanical

RESISTANCE, IMPEDANCE VALUES Table A: UL Listed configurations and performance capabilities Endurance from Line to Load Terminals as Circuit Breakers. (Values Based on Series Trip Circuit Breaker) Trip Free 1000

(AMPS)

HERTZ

VOLTS

100

Electrical Maximum Voltage 120/240VAC 60 Hz 10 Current Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0 O & 30.0 amps. Other ratings 1 H available, see ordering scheme. M Insulation Resistance Minimum of 100 Megohms at 500 S VDC. Dielectric Strength 0.1 UL, CUL - 1500 V 60 Hz for one minute between all electrically isolated terminals. PB-Series circuit breakers comply with the 0.01 8mm spacing and 3750V 60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces and between 0.001 adjacent 0.01 0.1 poles 1 10 RESISTANCE, IMPEDANCE VALUES Impedance from Line to Load Terminals Values from Line to Load Terminal. (Values Based on Series Trip Circuit Breaker)

1000

100

Ampere Rating

CURRENT (AMPS)

TOLERANCE (%)

0.100 - 5.0

± 15%

20.1 - 30.0

± 35%

5.1 - 20.0

10

± 25%

FIGURE 1

Pulse Tolerance Curve

1

Ir

0.1

60 Hz 1/2 Cycle Inrush Pulse Tolerance

Multiple of Rated Current

O H M S

AMPERE RATING

0.01

Time Delay Curves 22, 24, 26

12x

t

0.001 0.01

0.1

1

10

100

4.165

AMPERE RATING

8.33

16.67

Time in Milliseconds

Leakage To Ground CURRENT (AMPS)

TOLERANCE (%)

0.100 - 5.0

± 15%

5.1 - 20.0

± 25%

Standard Must Trip 120/240VAC 60 Hz FIGURE 1 Leakage Current Ratings 5 & 30 milliamps. 5± 1mA for UL943, other leakage ratings test to UL1053. For other ratings, consult factory. Trip Time 300 ms Max. @ 100%, 40ms Max. @ 500% of must trip leakage current. Test Button On unit face along side of actuator. 20.1 - 30.0

± 35%

10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. All PB-Series Circuit Breakers will trip on overload or ground fault, even when Handle is forcibly held in the ON position. Trip Indication The operating Handle moves positively to the OFF position when an overload or ground fault causes the breaker to trip.

Physical Number of Poles 1 - 3 poles, where the third pole is neutral Internal Circuit Config. Series Trip Weight Approximately 65 grams/pole. (2.32 ounces/pole.) Standard Colors Housing- Black; Actuator - See Ordering Scheme.

Environmental

Designed and tested in accordance with requirements of specification MIL-PRF- 55629 and MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Ultra- 100 short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -35° C to +65° C Corrosion Tested per UL943 FMG Test. 3 weeks @ 30°C 75% RH, 100ppb H2S, 20ppb CI2, 200ppb NO2

Agency Certifications

UL Listed UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) UL Standard 1077 Supplementary Protectors UL Standard 943 Class A Ground Fault Circuit Interrupters UL Standard 1053 Ground Fault Sensing and Relaying Equipment

*Manufacturer reserves the right to change product specification without prior notice.

www.carlingtech.com

27


PC-Series ELCI/GFCI

PC-Series ELCI/GFCI The PC-Series ELCI combines all safety characteristics of the PB-Series in a user friendly package featuring two integrated LED indicators, which distinguish if a breaker is closed with line voltage present, or has opened due to leakage current, or has opened due to over current, or is closed with no line voltage present. The optional hot/ neutral reversal detection and protection safeguards against incorrect circuit wiring. A specially designed panel seal that provides maximum environmental protection is also available. PC-SERIES SHOWN WITH SEAL

Handle Style Panel Seal

S S

HANDLE / INDICATE ON INDICATE OFF / SINGLE COLOR HANDLE / INDICATE ON INDICATE OFF ACTUATOR / SINGLE COLOR ROCKER ACTUATOR ROCKER ROCKER ACTUATOR ROCKER ACTUATOR LOAD NEUTRAL

TERMINAL TERMINAL LOCATIONS LOCATIONS

S S

INDICATE OFF / SINGLE COLOR ROCKER INDICATE OFFACTUATOR / SINGLE COLOR ROCKER ACTUATOR

HANDLE / INDICATE ON ROCKER/ INDICATE ACTUATOR HANDLE ON ROCKER ACTUATOR

TERMINAL LOCATIONS TERMINAL LOCATIONS

PCE PCE 120 VAC VERSION VAC VERSION W/ 120 REVERSE POLARITY W/ REVERSE POLARITY INDICATOR INDICATOR PCE 120 VACPCE VERSION W/ REVERSE POLARITY 120 VAC VERSION INDICATOR W/ REVERSE POLARITY INDICATOR

LINE 1

SOURCE NEUTRAL

LINE 1

SOURCE NEUTRAL LOAD HOT

LOAD NEUTRAL

LINE 1

SOURCE NEUTRAL

LOAD HOT 2

LINE 2

LOAD HOT 1

LINE

SOURCE NEUTRAL

LINE 2

LOAD HOT 2 OR 230V NEUTRAL

LINE 2 OR 230V NEUTRAL

LOAD HOT 1

LINE 1 1-Phase 120 / 240 VAC with Neutral Switching

1-Phase 120 VAC with Neutral Switching

LINE 2

LINE 1

1-Phase 240VAC 3.790 [96.27] 3.040 [77.22] 2.280 [57.91]

PCF PCFVERSION 120/240 VAC 120/240 VAC POLARITY VERSION W/ REVERSE W/ REVERSE POLARITY INDICATOR INDICATOR PCF 120/240 VAC PCFVERSION W/ REVERSE 120/240 VACPOLARITY VERSION INDICATOR W/ REVERSE POLARITY INDICATOR

1.660 [42.16]

1.453 [36.91]

1.260 [32.00]

2.062 [52.37]

.200 [5.08] .432 [10.97]

.750 [19.05] TYP. PCA PCB, PCD & PCE PCC & PCF

HANDLE ACTUATOR

NOTE: NEUTRAL & GROUND PIGTAIL WIRES - SUPPLIED 12" LONG MIN. (CIRCUIT CODES A,B,E & F)

28

2.

.156 DIA. [Ø3.96] 2 PLC'S. TYP. PER POLE

NOTE: NEUTRAL & GROUND PIGTAIL WIRES - SUPPLIED 12" LONG MIN. (CIRCUIT CODES A,B,E & F)

www.carlingtech.com

PANEL CUTOUT DETAIL

3.790 [96.27] 3.040 [77.22] 3.790 [96.27] 2.2803.040 [57.91] [77.22]

NOTE: NEUTRAL & GROUND PIGTAIL WIRES - SUPPLIED 12" LONG MIN. (CIRCUIT 2.280 [57.91]

ROC

3.040 [77.22] .156 DIA. [Ø3.96] CODES A,B,E & F) 2 PLC'S. TYP.

[77.22] 2.2803.040 [57.91]

TOLERANCES ±.005 [.12]


PC-Series ELCI/GFCI

Electrical

Mechanical

Current Ratings Voltage Rating Current Trip Level Current Trip Time Operating Frequency Interrupt Capacity Impedance

1 - 50 Amps maximum 120VAC, 120/240VAC, 240VAC 30mA & 6mA For 30mA leakage trip: ≤ 22.2mA, shall not trip 30mA, shall trip within .10 seconds The above complies with UL-1053 & ABYC E11. For 6mA leakage trip: ≤25ms The above complies with UL-943. 50/60 Hz for 30mA leakage trip 60 Hz for 6mA leakage trip 5,000 Amps

RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Braker)

1000

20.1 - 50.0

100

10

O H M S

1

0.1

10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. Trips on short circuit, overload or leakage to ground, even when actuator is forcibly held in the “On” position

Physical Number of Poles 1-pole (1 Circuit Breaker + 1 (Breakers only) GFCI Sensor Module), 120V 2-pole (2 Circuit Breakers + 1 GFCI Sensor Module), 120/240V or 120V with Neutral Break. 240VAC two pole. 3-pole 120/240V with Neutral Break (Sensor module has 2 pole width) Circuit Breaker Line Side: #10-32, Threaded stud. Termination GFCI Sensor Module Load Side: #10-32 threaded stud. Neutral pigtail. Mounting Front Panel, #6-32 and M3 threaded inserts. Actuator Handle, Flat Rocker, Curved Rocker (with or without rocker guard), Push-to-Reset Rocker

Environmental

Designed and tested in accordance with requirements of specification MIL-PRF- 55629 and MIL-STD-202G as follows:

0.01

0.001 0.01

Endurance Trip Free

0.1

1

10

100

AMPERE RATING

Innovative Features CURRENT (AMPS)

TOLERANCE (%)

0.100 - 5.0

± 15%

20.1 - 30.0

± 35%

Indicator Neutral Protection Test Button 5.1 - 20.0

± 25%

FIGURE 1

Two integrated LEDs, Red & Green

 Green LED On, Red LED Off Line Voltage is present, the breaker is closed, and the device is protecting the circuits against over current and leakage current.  Green LED Off, Red LED On The device has detected leakage current and has opened the circuit breaker.  Green LED Flashing, Red LED Off The circuit breaker has opened due to over current or has been turned off manually  Green LED Off, Red LED Off Line Voltage is not present  Green LED Flashing, Red LED Off, Amber LED ON Indicates Hot & Neutral are reversed and the circuit breaker is open When neutral is grounded on load side of circuit Located on Ground Fault Module

Shock Withstands 100 G, 6ms, sawtooth at rated current per Method 213, Test Condition “I”. Vibration Withstands 0.06” excursion from 10-55 Hz, and 10 G 55-500 Hz, a rated current per Method 204C, Test Condition A. Instantaneous & ultrashort curves tested at 90% of rated current. Moisture Resistance 93% RH at 30°C for 168 Hours. Operating Temperature -35°C to +66°C Corrosion UL-943-6.21, 3 weeks Humidity: 30±2°C, 70±2% relative humidity Mixed Flowing Gases: 100 ppb H2S, 20 ppb CI2, 200±50 ppb NO2

Agency Certifications

UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) UL Standard 1077

Supplementary Protectors

UL Standard 943 & CSA Certified

Class A Ground Fault Circuit Interrupters

UL Standard 1053

Ground Fault Sensing and Relaying Equipment

UL Standard 1500

Ignition Protection

*Manufacturer reserves the right to change product specification without prior notice.

www.carlingtech.com

29


Literature

There are several catalogs available featuring complete details on all Carling Technologies products. Below is a complete list of catalogs available on print and online as eCatalogs and downloadable PDF files. Please visit our website at carlingtech.com or scan the QR codes below for complete details.

Carlingtech.com

Visit us online for complete products and company information.

Switches & Controls Switches and Controls Rocker, Toggle, Pushbutton & Rotary

Hydraulic Magnetic Circuit Protection

Hydraulic/Magnetic Circuit Breakers

Features complete line and ordering details of Switches and Controls products including Rocker, Toggle, Pushbutton, and Rotary style switches.

Features complete line and ordering details of all hydraulic/magnetic circuit breakers.

Thermal’s

GFCI’s

Thermal Circuit Breaker Reliable, Cost-effective Circuit Protection

Features complete line and ordering details of all thermal circuit breakers.

30

GFCI/ELCI Circuit Protection

Features complete line and ordering details of all GFCIs/ELCIs.

www.carlingtech.com


Literature

On-Off Highway ON–OFF Highway Switches & Controls CATALOG

Features specific transportation products such as switches, controls and custom solutions.

Marine Marine Switches, Circuit Breakers & ELCI/GFCIs

Telecom/Datacom Telecom/Datacom Circuit Protection CATALOG

Features all marine application products such as switches, ELCIs, thermal and hydraulic/ magnetic circuit breakers.

Features complete line of hydraulic/magnetic circuit protection products specific for telecom and datacom systems.

Military

Renewable Energy

Military Grade

COTS Switches & Circuit Breakers

Renewable Energy Circuit Breakers and Disconnects

CATALOG

Features all COTS (Commercial-Off-The-Shelf ) Military grade switches and circuit breakers.

www.carlingtech.com

Features a complete line of circuit protection and disconnect products for photovoltaic energy systems.

31


Notes

32

www.carlingtech.com


Notes

www.carlingtech.com

33


Worldwide Headquarters

Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: sales@carlingtech.com • www.carlingtech.com East Region Sales Office, CT • ersm@carlingtech.com Midwest Region Sales Office, IL • mrsm@carlingtech.com West Region Sales Office, CA • wrsm@carlingtech.com

Asia-Pacific Headquarters

Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Int + 852-2737-2277 • Fax: Int + 852-2736-9332 Email: sales@carlingtech.com.hk Shenzhen, China • shenzhen@carlingtech.com Shanghai, China • shanghai@carlingtech.com Pune, India • india@carlingtech.com Kaohsiung, Taiwan • taiwan@carlingtech.com Yokohama, Japan • japan@carlingtech.com

Europe / Middle East/Africa Headquarters

Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Int + 44 1392-364422 • Fax: Int + 44 1392-364477 Email: ltd.sales@carlingtech.com GmbH, Germany • gmbh@carlingtech.com SAS, France • sas@carlingtech.com

Marine-C_02_2015


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.