MEDICARE GAS PIPELINE SERVICES Introduction Letter
We are pleased to introduce our esteem organization. The details of the Products and System we offer are as under: -
Design, supply, Installation, Testing and Commissioning of Central Medical Gas Pipeline System with all accessories and basic systems.
Bed Head Panels (Vertical and Horizontal) with / without Medi-Rail System.
Rigid / Swivel / Single Arm / Double Arm Pendants for OT/ ICU. Area Alarm Panel / Master Alarm Panel for Medical Gases. Medi-Rail System with mounting accessories. Hospital Track curtains System. Laminar Air flow for OT. Nurse Call System. Anesthesia Machine / Vaporizer. We assure you of our Best Quality of our Products, Services and Timely Delivery.
Medicare Gas Pipeline Services 2/17, BMC Colony, Naigaon Cross Road, Dadar East, Mumbai -400014 Phone: (022) 652-91027 Website :- www.mgpservice.com E-mail – mgpservices@gmail.com
For more information on our products, you can visit on to our website: www.mgpservice.com Thanking You, Yours faithfully
Rajesh Mate.
MEDICARE GAS PIPELINE SERVICES MATERIAL (PIPE) Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered & Degreased materials confirming to HTM 2022 Standards. Pipe sizes to be used as under: 28mm OD x 1.2 mm thick 22mm OD x 0.9 mm thick 15mm OD x 0.9 mm thick 12mm OD x 0.7 mm thick Fittings used for connecting copper tubing shall be made of Copper and brazed type Connection as per BS: 864: Part 2:1983. All pipe-jointing fittings are made of Copper as per BS 864 Standards and suitable for a steam of working pressure of 17 bars and especially made for brazed socket type connections. Shut off valves suitable for the pipe diameter are of non lubricated 90 degree turn lever & having stainless steel hard chrome brass body with PTFE seat and S.S. ball. Sizes will be appropriate for copper pipes with screw threaded ends and brass adapter .All valves shall be pneumatically tested for twice the working pressure and degreased for medical gas service before supply. INSTALLATION: Installation of piping shall be carried out with utmost cleanliness. Only pipes, fittings and valves which have been degreased. Pipe fixing clamps shall be non-ferrous or non-deteriorating plastic suitable for the diameter of the pipe. TEST: After erection, all the pipes cleaned or purged with gas, and complete new system will be tested at 1 1/2 times of working pressure for 24 hours. PAINTING: All existing and proposed exposed pipes will be painted with two coats of synthetic enamel paint & color codification as per IS-2379 of 1963.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES DIGITAL CONTROL PANEL FOR OXYGEN / NITROUS
The Oxygen Control Panel shall be of microprocessor based Digital Display Type. Pressure reduction shall be in two stages. Panel shall be integrated with pressure gauges inside panel on downstream of pressure regulator. Panel shall be fitted with standby line regulator. Line regulators shall have pressure relief mechanism for testing and servicing purpose.
Panel shall be Fully Automatic and shall switch over from “Bank in Use” to „Reserve Bank‟ without fluctuation in delivery line pressure and without the need of external electrical power. After the switch–over, the “Reserve Bank” shall become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank”. The Control Panel will be powered by a microprocessor. The unit shall be compact and enclosed in NEMA 1 enclosure.
A Microprocessor circuit board assembly shall provide a relay output to give indication when or just before the manifold switches from one bank of cylinders to another. The switch over shall be mechanically controlled, not electrically.
To avoid excess pressure being supplied to the distribution system, a pneumatically relief valve for the line regulator shall be incorporated. An intermediate pressure relief valve shall be installed between the highpressure regulators and the line delivery regulators.
The control panel incorporates six coloured LED‟s, three for the Left Bank and three for the Right Bank: Green for Bank in use, Amber for Bank ready and Red for Bank empty. Both the Left and Right bank pressures and the main line pressure should be displayed on the front door of the cabinet by means of LED's. All pressure transducers, micro switches, and display LED‟s shall be pre-wired to an internal microprocessor circuit board.
All components inside the Control Panel like Pressure Regulators, piping and control switching equipment shall be cleaned for Oxygen Service and installed inside the cabinet to minimize tampering with the regulators or switch settings
The Control Panel should be made to provide Heavy Duty with a Flow Capacity of over _____(as per requirement of the hospital) LPM..
Panel shall be compatible for interfacing with the Information Management System.(optional)
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES FULLY / SEMI AUTOMATIC CONTROL PANEL OXYGEN / NITROUS OXIDE SYSTEM
Control Panel have two first stage regulators, each capable of delivering 120 psig outlet pressure. The First stage regulator connected to the second stage regulator which will deliver an outlet pressure of 60 psi. The First two regulators meant for first stage will be capable of switchover system incorporated from “Running” to “Reserve” bank due to differential pressure. The Control Panel provide for two individual content contact pressure gauges to indicate the cylinder pressure in the two wings of the manifold and common pressure gauges to indicate the delivery/line pressure. Control panel have audio alarm for bank changeover. The control panel has built in signal lamp indications for changeover. Control panel covered with suitable cover indicating the respective services.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES MANIFOLD SYSTEM (OXYGEN / NITROUS OXIDE).
Manifold shall consist of two high-pressure header bar assemblies to facilitate connection of primary and secondary cylinder supplies. Each header bar shall be provided with ------ numbers( as per hospital requirement) of cylinder pigtail connections to suit cylinder valves as per IS 3224 incorporating a check valve at the header connection. Manifold should be suitable to withstand a pressure of 150 Kg/cm2, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Cylinders and manifold. The high-pressure header bar shall be designed in such a manner that it can be extended to facilitate additional cylinder connections. Each header bar assembly shall be provided with a high-pressure shut-off valve. Top frame comprising of high pressure copper pipes of size 1/2” I.D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves ; high pressure copper tail pipes, made of high pressure copper pipe of size 1/4” I.D. x 15 swg.
The manifold should be so designed that it shall suit easy cylinder changing and positioning.
The middle and bottom frame to be provided to fit both round and flat bottom cylinders safely.
EMERGENCY OXYGEN SYSTEM / NITROUS OXIDE SYSTEM.
It will have emergency arrangement of one set of two-cylinder configuration with Copper tail pipes, Non Return Valves & high flow regulator with pressure gauges for Cylinder & line pressure and safety valve. Pressure regulator shall be detachable from the manifold.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES MEDICAL / SURGICAL COMPRESSED AIR SYSTEM (4 BAR/7 BAR)
Air cooled Oil free Air compressor with CMF Japanese Technology continuously rated.
Anest Iwata Oil Free Compressors deploy the
PATENTED CMF Technology and are the ONLY of
their kind in the world. Critical Maintenance Free (CMF) technology gives you combination of Air Cooled Operation, 100% Oil free air, Continuous and heavy duty running and NO risk of seizure.
Life of Piston Rings is 10,000 hrs compared to others which have only 1200 hrs or less in Teflon type rider ring compressors.
The heart of CMF Technology is the Patented „Composite Resin Piston‟. This ensures that the piston can withstand continuous use under high temperature (up to 300 deg C) and possesses high resistance to extreme environments. This has replaced the Conventional Rider Ring Technology, which used to give inconsistent operation and often resulted in seizure. 1 no. Heatless Air Dryer.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES VACUUM / SUCTION PUMP SYSTEM
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES ANAESTHETIC GAS SCAVENGING SYSTEM Introduction Anaesthetic Gas Scavenging System is used to remove anaestheic gases directly from patient connection from Anaesthesia Machine by mixer, AGSS outlet pipeline & AGSS Exhauster to provide clean and free Anaesthesia Gases environment in operation theaters.
AGSS is designed to meet the requirement of HTM2022 C11 and EN737 and types of Anaesthetic Gas Scavenging Systems is determined based on the circulation and requirement of HTM 2022 and EN 737 requirements.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES MEDICAL GAS OUTLETS FOR WALL/BHP/ PENDANT It consists of a self sealing valve (colored white for Oxygen , Blue for Nitrous Oxide, Grey for Air and yellow for Vacuum), and plastic cover (coloured white for Oxygen, Blue for Nitrous Oxide, Grey for Air and Black for Vacuum). Supply of gases can be obtained instantly by inserting a non – interchangeable safety keyed plug connector into the outlet point. Similarly by removing the plug connector the supply of gases can be terminated immediately.
Scharader Outlet
Front Loading Double Lock Outlet (Puritan Bennett)
Front Loading BS Type Outlet
Front loading Outlet
Double Parking Outlet. (Hook loose Type)
Front Loading DIN Type
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES BPC FLOW METER BACK PRESSURE COMPENSATED FLOWMETER Sturdy and reliable Flow Meter Unit for an accurate measuring of flow of gases Chromium plated Brass Body Metering tube and cover made of Unbreakable Poly carbonate Flow adjustment by Needle Valve equipped with inlet filter- 100um Flow rate range 0- 15 liters per minute Flush Flow 60 liters per minute Read the flow on the center of the ball Inlet pressure 60 psi BUBBLE HUMIDIFIERS
With Lid made of ABS Plastic, Jar made of Unbreakable Poly Carbonate, Valve pressure Brass Chromium plated, Humidifier jar may be steam autoclaved/gas sterilized.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES WARD SUCTION UNIT WARD SUCTION UNIT Wall Mountable Ward Vacuum Unit Capacity of Jar – 600ml / 2000ml. Flow Range Control 0 To 700 Mm./Hg. Over Flow Safety Valve Provided In The Lid Assembly LID Made Of ABS Plastic Jar Made Of Unbreakable Poly Carbonate Jar Can Be Steam Sterilized Up To 134 Degree Celsius Vacuum Control Regulator With ON/OFF Knob It will be supplied with high pressure hose at inlet and low pressure hose at collection end of the jar.
MOBILE THEATRE SUCTION UNIT U nbreakable Poly Carbonate Collection jars 2 Nos Capacity 2000ml each ABS Lid with over flow safety valve. Special 3 way valve provided to operate either left hand side or right hand side and also both can be operated simultaneously.
Regulator provided to control the negative pressure from 0 to 700 mm./ Hg. with ON /OFF knob. All the items should assembled on a Aluminum powder coated trolley with castors for ease of mobility.
With 1 mtr high pressure hose at inlet and 2 Mtr low pressure hose at collection end of the jar.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES WARD SUCTION UNIT
MOBILE THEATRE SUCTION UNIT WITH 2000 ML JAR
MOBILE FLOOR SUCTION TROLLEY can be constructed using suction accessories. Mobile theatre suction was developed to provide a single suction source. Designed with low center of gravity to help prevent tip overs. Provided with castor wheels and filter.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES ALARM SYSTEM FOR MEDICAL GAS SYSTEMS Area Alarm Panel Wall Mountable Digital display of line pressure in Psig. Audio Visual Alarm for High & Low. Reliable Pressure sensor. Free Retardant enclosure. The alarms should have pressure sensors with an in-built On-Off switch. The system can be kept off as and when necessary. The audio alarms will become active in case of any abnormality in the pressure and can be acknowledged by pressing the MUTE button provided in the system.
The audio alarm will restart automatically in case the pressure does not come back to the normal range within 30 minutes, thus reminding the user that the fault is still unattended.
The feather touch buttons ensure ease of use of the system. A battery pack can be opted for uninterrupted power supply to the system and can give 2 hours back-up supply.
The enclosure made of fire-proof material as desired by international standards.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES
ANALOGE AREA ALARM PANEL
DIGITAL AREA ALARM PANEL
MASTER ALARM PANEL
AREA VALVE SERVICE UNIT FOR ALL GASES.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES O T PENDANT
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES TYPE OF BED HEAD PANEL Bed Head Panel design shall be as following :Horizontal Bed Head Panel with provision for Gas Outlets & Electrical 5/15 Amps Switch , Sockets, Nurse Call cutout as per requirement, each Bed Head Panel can accommodate following :-
Two each of Oxygen & Vacuum Outlets. Four multi- pins 5/15 Amps, Switch Sockets outlets combine Medi-rail Provision for Nurse Call Cutout.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES TYPE OF BED HEAD PANEL
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES TYPE OF BED HEAD PANEL
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES HOSPITAL CURTAIN SYSTEM Best known for their use in multi-bed hospital wards these systems have numerous other applications including as shower rails, in surgery and other health separation areas and as industrial separation and overhead tracking.
They offer total flexibility at reasonable cost and can be curved or formatted to virtually any requirement. Fitting can be to the wall or ceiling or both. Efficient, smooth and quiet operation: the curtain can move all around the track with no impediment due to its skilful design. Long-lasting and maintenance free.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES WIRELESS NURSE CALLING SYSTEM
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES WIRELESS NURSE CALLING SYSTEM
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES NURSE CALLING SYSTEM For those vital minutes in providing treatment to the patients, Medical Gas Pipeline Services Introduces the digital nurse calls system for multi specialty large hospital that‟s the picture of quiet efficiency. The system configuration.
Wall Unit This module will be installed at each bed; sleek design aluminum Panel with screw attachment & multi color powder coating. The front panel will have the following : 1.
3 color indicators :
RED…….Call Green…...Ready Yellow…..Wait 2.
Reset switch
3.
Hanging cord
Patient Switch This will be installed at the nursing station. Microprocessor based technology the enclosure is aluminum power coated. With table top or wall mounted design. The central monitor will have the following:
Bright red digital display for bed nos.
Single 3 Sec beep on call or Periodic beep.
Acknowledgement switch on the monitor.
1.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES NURSE CALLING SYSTEM
Flashing display on call & freeze mode on wait.
Central monitor available in 10, 20, 30, 40, beds capacity
Siren mode if the patient is not attended after providing wait signal.
Electrical Installation The system works on 4 core shielded single wire which should be laid from every bed to the nursing station through concealed conduits. The central monitor works on 230v 50hz supply. Only DC voltage is supplied to The wall unit & patients switch as such the risk of micro shocks & Leakage current Shocks are eliminated.
The system is fully hassling free & user friendly after installation it is kept on 24 hrs. 365 days for the benefit of the patients.
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES ANEASTHESAI MACHINE Mark IV Anaesthesia Machine
Rota meters:
230 mm long accurately Calibrated Rotating Bobbing Flow meters.
Oxygen : 100
ml / min to 8 LPM &
Ether: Eather
vaporizer with Bottle (50 cc to 300 cc) supplied as standard accessories. Goldman
Nitrous Oxide : 200ml / min to 12 LPM
vaporizer may be provided as per customer‟s choice.
Non-Return-cum-Pressure
Relief valve: Blow off excess pressure in the circuit. Release pressure 100
CM H2O+10%, H2O-10%.
Change
over Unit: Emergency oxygen Flush Button is provided at table Top Level on the front.
flow range 35 LPM calibrated to 60 PSI (+5,-5)
Regulator:
2 No's Nitrous Oxide Regulator (cut off facility) & 2 No's Oxygen Preset Regulator,
been provided with 2 No's Nitrous Oxide & 2 No's Oxygen pressure gauge (2.5” ф) fixed on bend gauge post.
Alarm:
Oxy failure alarm, if flow of oxygen (02) goes flow below 2.5 LPM
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES ANEASTHESAI MACHINE ECON Anaesthesia Machine
ROTAMETERS: 230
Oxygen: 100ml/min to 8 LPM
Nitrous Oxide:
EATHER VAPORIZER: The Vaporizer of Eather or
EMERGENCY UNIT: Emergency oxygen flush button is provided at the
mm long accurately calibrated rotating bobbin flow meters.
200 ml/min to 12 LPM
avoid accidental passing.
Halothane is supplied as standard accessories.
back bar & guarded to FLOW RANGE: 35LPM calibrated at 60 PSI (+5%, -5%)
Patient Circuit: Standard Magill‟s Circuit consisting of Bag Mount – 01 No corrugated Hose -01 No.Angle Mount -01 No., Catheter Mount -01 No., Face Mask -01 No., Rebreathing Bag -01 No.,Key Spanner -02 No
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
MEDICARE GAS PIPELINE SERVICES Medical Gas Pipeline Installation List HOSPITAL NAME
OXYGEN
NITROUS OXIDE
AIR
VACUUM
B.J WADIA HOSPITAL FOR CHILDREN, PAREL, (MUMBAI) NOWROSJEE WADIA MATERNITY HOSPITAL, PAREL, (MUMBAI) B.J WADIA HOSPITAL FOR CHILDREN, PAREL, (MUMBAI) NOWROSJEE WADIA MATERNITY HOSPITAL, PAREL, (MUMBAI) SHIVAM HOSPITAL (DOMBIVLI EAST)
AMC
AMC
AMC
AMC
AMC
AMC
AMC
AMC
O2
N2O
AIR
VAC
O2
N2O
AIR
VAC
MAULI HOSPITAL, (Dr. RAHUL YANDE, BEED)
O2
NIRAMAYA HOSPITAL KHARGHAR, (NAVI MUMBAI)
O2
N2O
SANJEEVANI SURGICAL AND GENERAL HOSPITAL, MALAD EAST,(MUMBAI) MARWAD CIVIL HOSPITAL, DAMAN, (GUJRAT)
O2
N2O
AIR
VAC
O2
N2O
AIR
VAC
DHAMANKAR HOSPITAL, ALIBAG. (DIST: RAIGAD)
O2
SHREE DATTA SHETKARI SAHAKARI SAKHAR KARKHANA LTD CHARITABLE TRUST.( KOLHAPUR) SHREE SIDDHAKALA GEN HOSPITAL, PEN (DIST: RAIGAD) YCM HOSPITAL PIMPRI PUNE
O2
N2O
AIR
VAC
SHREE KRISHNA HOSPITAL (MUMBAI)
O2
SHRADDHA HOSPITAL (DR. SHIRPURKAR, BEED)
O2
ESIS HOSPITAL. (ANDHERI)
O2
IVF LAB ADITYA BIRLA MEMORIAL HOSPITAL. (PUNE)
CO2
IVF LAB FORTIS HIRANANDANI HOSPITAL (NAVI MUMBAI) NASHIK RUGHNALAY. (NASHIK)
O2
VAC
O2
VAC
O2
AIR
O2 O2
N2O
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
ST. ELIZABETH HOSPITAL (MUMBAI)
O2
DR. KAUSHAL KADAM HOSPITAL (MUMBAI)
O2
ESIS HOSPITAL. (ANDHERI)
O2
MANGAL PRABHU GEN. HOSPITAL (NAVI MUMBAI)
O2
INS ASVINI HOSPITAL (MUMBAI)
O2
PAITHANKAR HOSPITAL (DR. PAITHANKAR, BEED)
O2
NIRAMAYA HOSPITAL KHARGHAR, (CHEMBUR MUMBAI) SHK. ZAYED MATERNITY & CHILD HOSPITAL SANA. (REP. OF YEMEN.) SHIVANI MEDICAL CENTER. (BORIVALI WEST MUMBAI) YASHODHA HOSPITAL BORLI. (RAIGAD)
O2
ANAND MEDICAL AND EDUCATIONAL TRUST (NAVI MUMBAI) SIR J. J. GROUP OF HOSPITALS (MUMBAI)
O2
DR. GANGWAL (THANE)
O2
DR. ANAND RANE (BORIVALI)
O2
NOWROSJEE WADIA MATERNITY HOSPITAL, PAREL, (MUMBAI) LATUR CRITICAL HOSPITAL, (DR CHAUDHARI)
O2
ESIS HOSPITAL. (ANDHERI)
O2
MAHAVIR HOSPITAL (ANDHERI)
O2
MGM HOSPITAL PAREL
O2
IVF CRAAFT INDIA PRIVATE LTD. ( DR. SATISH SHARMA ANDHERI)
VAC
O2 O2 VAC
O2
AIR
VAC
N2O
AIR
VAC
O2
N2O
CO2
VAC
L B S HOSPITAL (BHOPAL)
O2
N2O
AIR
VAC
OM CLINIC ( DR. SUNIL NANDGAONKAR, MAHAD)
O2
P D HINDUJA HOSPITAL & MEDICAL RESEARCH CENTER MAHIM. (13TH FLOOR) SUGUN HOSPITAL (DR.KAILASH BOTHARE ANDHERI)
O2
AIR
VAC
DR. PRASHANT HATKAR (BANDRA MUMBAI)
O2
PRATAPNAGAR RAIWAY HOSPITAL (BARODA)
O2
NOVA MEDICAL CENTERS PVT. LTD
AMC
DR ANAND WAGALE (ROHA, RAIGAD)
O2
RELIANCE INDISTRIES LTD. (IPCL NAGOTHANE)
O2
O2
O2
N2O
VAC
VAC
2/17, BMC Colony, Naigaon Cross Road, Phone: (022) 652-91027, Dadar East, Mumbai -400014, Phone: (022) 652-91027 Website - www.mgpservice.com, E-mail – mgpservices@gmail.com, medicaregaspipeline@yahoo.co.in
BHYCULLA RAILWAY HOSPITAL
O2
MGM MEDICAL COLLEGE & HOSPITAL (AURANGABAD)
O2
N2O
AIR
VAC
MIT HOSPITAL (AURANGABAD)
O2
N2O
AIR
VAC
SHRADHA MATERNITY NURSING HOME PVT LTD BHAYANDER MITI LIFELINE HOSPITAL (DAHISAR MUMBAI)
O2
N2O
O2
N2O
AIR
VAC
DR RAMESH WAGHAMARE (VASAI)
O2
DR SAROJ TAMBOLI MEMORIAL HOSPITAL (ALIBAUG)
O2
PATANKAR HOSPITAL (ALIBAUG)
O2
DR DHIRAJ MAHAGDE (THANE)
O2
SEVEN ELEVEN HOSPITAL (MIRA ROAD MUMBAI)
O2
N2O
AIR
VAC
DR VIKAS AGRAWAL HOSPITAL (KANDIWALI MUMBAI)
O2
ACHARYA SHRI NANESH HOSPITAL (BELAPUR NAVI MUMBAI) KHARGHAR MEDICITY (KHARGHAR NAVI MUMBAI)
O2
ASHVINI MATERNITY & PEDIATRIC NURSING HOME (DADAR MUMBAI) DAKE HOSPITAL PVT. LTD. (PANVEL)
O2 O2
N2O
AIR
VAC
K L S MEMORIAL HOSPITAL IRLA (ANDHERI MUMBAI)
O2
N2O
AIR
VAC
DNA ARCHITECH DESIGNER PVT. LTD. (DADAR MUMBAI) BOMBAY ENDOSCOPY ACADEMY & CENTRE FOR MINIMALLY INVASIVE SURGERY & RESEARCH CO PVT LTD NOWROSJEE WADIA MATERNITY HOSPITAL, PAREL, (MUMBAI) TERNA SAHYADRI HOSPITAL, (NERUL)
O2
N2O
O2
N2O
AIR
CO2
O2
N2O
AIR
VAC
AIR
VAC
SMBT SEVABHAVI TRUST HOSPITAL, IGATPURI (NASHIK) MEDIPULSE HOSPITAL, (JODHPUR)
O2
N2O
AIR
VAC
O2
N2O
AIR
VAC
HOLY FAMILY HOSPITAL. (MUMBAI)
O2
AIR
VAC
PANACEA HOSPITAL, (PANVEL)
O2
N2O
AIR
VAC
INDIRA IVF CENTER, (PUNE)
O2 N2O
AIR
VAC
JODHPUR HEALTH CARE PVT LTD (RAJASTHAN)
VAC
VAC
O2
AIR
O2
O2
CO2
VAC