Santa Ana Multi-Family Housing

Page 1


CAB. CABINET

CEM. CEMENT

C.JT CONTROL .JOINT

CL.CLOSET

CLG. CEILING

CONC. CONCRETE

CORD. CORRIDOR

CTR. CENTER

DBL. DOUBLE

DEMO. DEMOLITION

DIM.

J.JOIST

JT. JOINT

LW. LINEWEIGHT

MECH. MECHANICAL MTL. MATERIAL MUL. MULLION

(N)NEW NO. NUMBER

OPP. OPPOSITE

PAR PARALLEL

PFB. PREFABRICATED

PKG. PARKING

PLAS. PLASTER

P.L PROPERTY LINE

PLYWD. PLYWOOD

PNT. PAINT

P.S.F PER SQUARE FOOT

P.S. I PER SOUARE INCH

PTN PARTITION

PT. POINT

PVMT. PAVEMENT

REM. REMOVE REQD. REQUIRED REV. REVISION

SCHED SCHEDULE SEC. SECTION SHTH. SHEATHING SPECS. SPECIFICATIONS SUS. SUSPENDED

T.O TOP OF

TOF TOP OF FOOTING

TOG TOP OF GRADE

TOFR TOP OF FRAMING

TOS TOP OF STEEL

TOW TOP OF WALL TYP. TYPICAL

W/ WITH WD WOOD

W/O WITHOUT WP WATERPROOF WT. WEIGHT

PROJECT VISUALIZATION

SYMBOLS

DATUM ( ELEVATION )

VICINITY MAP

SHEET INDEX SHEET INDEX

COVER SHEET

CODE ANALYSIS SITE PLAN SITE SECTION OCCUPANCY EGRESS PLANS

GROUND FLOOR PLAN PODIUM FLOOR PLAN

FLOOR PLANS

VIZUALIZATIONS

BUILDING SECTIONS

WALL SECTION

UNIT PLAN

ADA BATHROOM

INTERIOR VISUALIZATIONS

ENLARGED STAIR PLAN / SECTION

WALL AND FLOOR ASSEMBLIES

DETAILS

WINDOW AND DOOR SCHEDULE

APPLICABLE CODES:

CALIFORNIA BUILDIND CODE (CBC) 2022

CALIFORNIA MECHANICAL CODE (CMC) 2022

CALIFORNIA ELECTRICAL CODE (CFC) 2022

CALIFORNIA PLUMBING CODE (CPC) 2022

CALIFORNIA ENERGY CODE 2022

CALIFORNIA GREEN BUILDIND STANDARDS CODE 2022

CALIFORNIA RESIDENTIAL CODE (CRC) 2022

AMERICAN’S WITH DISABILITIES ACT (ADA)

NATIONAL FIRE PROTECTION ASSSOCIATION STANDARD (NFPA 13 AND 17)

LOS ANGELES MUNICIPAL CODE SANTA ANA MUNICIPAL CODE

CALIFORNIA BUILDING CODE 2022

310.1 RESIDENTIAL GROUP R

RESIDENTIAL GROUP R INCLUDES, ALONG OTHERS. THE USE OF A BUILDING OR STRUCTION, OR PORTION THEREOF, FOR SLEEPING PURPOSES WHEN NOT CLASSIFIED AS AN INSTITUTIONAL GROUP OR WHEN NOT REGUALTED BY THE CALIFORNIA RESIDENTIAL CODE. GROUP R OCCUPANCIES NOT CONSTRUCTED IN ACCORDANCE WITH THE CALIFORNIA REISDENTIAL CODE AS PERMITTED BY SECTIONS 310.4.1 AND 310.4.2 SHALL COMPLY WITH SECTION 420.

310.3.1. RESIDENTIAL GROUP R-2

RESIDENTIAL GROUP R-2 OCCUPANCIES CONTAINING SLEEPING UNTIS OR MORE THAN TWO DWELLING UNTIS WHERE THE OCCUPATNS ARE PRIMARILY PERMANENT IN NATURE, INCLUDING:

APARTMENT HOUSES - LARGE FAMILY CHILD CARE, SMALL FAMILY CHILD CARE

CONGREGATE RESIDENCES (NONTRANSIENT WITH MORE THAN 16 OCCUPANTS)

BOARDING HOUSES (NONTRANSIENT)

COVENTS

DORMITORIES

FRATERNITIES OR SOROITIES MONASTERIES

HOTELS (NONTRANSIENT)

LIVE/WORK UNITS

MOTELS (NON TRANSIENT)

VACATION TIME SHARE PROPERTIE

705.5 FIRE-RESISTANCE RATINGS FOR OTHER THAN GROUP A, E, H, I, L, AND R OCCUPANCIES, HIGH-RISE BUILDINGS, AND OTHER APPLICATIONS LISTED IN SECTION 1.11 EXTERIOR WALLS SHALL BE FIRE RESISTANCE RATED IN ACCORANCE WITH TABLES 601 AND 602 AND THIS SECTION. THE REQUIRED FIRE RESISTANCE RATING OF EXTEIROR WALLS WITH A FIRE SEPARATION DISTANCE OF GREATER THAN 10 FEET (3048 MM) SHALL BE RATED FOR EXPOSURE TO FIRE FROM THE INSIDE. THE REQUIRED FIRE-RESISTANCE RATING OF EXTERIOR WALLS WITHA FIRE SEPARATION DISTANCE OF LESS THAN OR EQUAL TO 10 FEET (3048 MM) SHALL BE RATED FOR EXPOSURE TO FIRE FROM BOTH SIDES

706.1.1 PARTY WALLS

ANY WALL LOCATED ON A LOT LINE BETWEEN ADJACENT BUILDING WHICH IS USED OR ADAPTED FOR JOINT SERVICE BETWEEN THE TWO BUILDINGS, SHALL BE CONSTRUCTED AS A FIRE WALL IN ACCORDANCE WITH SECTION 706. PARTY WALLS SHALL BE COSNTRUCTED WITHOUT OPENINGS AND SHALL CREATE SEPARATE BUILDINGS.

1119A.3 WIDTH

INTERIOR ACCESSIBLE ROUTES SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL NOT BE LESS THAN 44 INCHES (1118 MM) IN WIDTH. INTERIOR ACCESSIBLE ROUTES SERVING AN OCCUPANT LOAD OF LESS THAN 10 SHALL NOT BE LESS THAN 36 INCHES (914 MM) IN WIDTH

1206.2 AIRBORNE SOUND

WALL PARTITIONS AND FLOOR-CEILING ASSEMBLIES SEPARATING DWELLING UNITS AND SLEEPING UNITS FROM EACH OTHER OR FROM PUBLIC SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS OF NOT LESS THAN 50 WHERE TESTED IN ACCORDANCE WITH ASTM E90 OR HAVE A NORMALIZED NOISE ISOLATION CLASS (NNIC) RATING OF NOT LESS THAN 45 IF FIELD TESTED, IN ACCORDANCE WITH AST E336 FOR AIRBORNE NOISE. ALTERNATIVELY, THE SOUND TRANSMISSION CLASS OF WALLS, PARTITIONS, AND FLOOR-CEILING ASSEMBLIES SHALL BE ESTABLISHED BY ENGINEERING ANALYSIS BASED ON A COMPARISON OF WALLS, PARTITIONS, AND FLOOR CEILING ASSEMBLIES HAVING SOUND TRANSMISSION CLASS RATINGS AS DETERMINED BY THE TEST PROCEDURES SET FORTH IN AST E90. PENETRATIONS OR OPENINGS IN CONSTURCTION ASSEMBLIES OR PIPING; ELECTRICAL DEVICES; RECESSED CABINETS; BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR EXHAUST DUCTS SHALL BE SEALED, LINED, INSULATED OR OTHERWISE TREATED TO MAINTAIN THE REQUIRED RATINGS. THIS REQUIREMENT SHALL NOT APPLY TO ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT FITTING TO THE FRAME AND SILL.

1206.3 STRUCTURE-BORNE SOUND FLOOR-CEILING ASSEMBLIES BETWEEN DWELLINGS UNITS AND SLEEPINIG UNITS OR BETWEEN DEWLLING UNIT OR SLEEPING UNIT AND A PUBLIC OR SERVICE AREA WITHIN THE STURCTURE SHALL HAVE AN IMPACT INSULATION CLASS RATING OF NOT LESS THAN 50 WHERE TESTED IN ACCORDANCEWITH ASTM E492, OR HAVE A NORMALIZED IMPACT SOUND RATING (NISR) OF NOT LESS THAN 45 IF FIELD TESTED IN ACCORDANCE WITH A ST E1007. ALTERNATIVELY, THE IMPACT INSULATION CLASS OF FLOOR-CEILING ASSEMBLIES SHALL BE ESTABLISHED BY ENGINEERING ANALYSIS BASED ON A COMPARISON OF FLOOR-CEILING ASSEMBLIES HAVING IMPACT INSULATION CLASS RATINGS AS DETERMINED BY THE TEST PROCEDURES IN AST E492. EXCEPTION: IMPACT SOUND INSUALTION IS NOT REQUIRED FOR FLOOR CEILING ASSEMBLIES OVER NONHABITABLE ROOMS OR SPACES NOT DESIGNED TO BE OCCUPIED, SUCH AS GARAGED, MECHANCIAL ROOMS OR STORAGE AREAS.

1206.4 ALLOWABLE INTERIOR NOISE LEVELS INTERIOR NOISE LEVEL ATTRIBUTABLE TO EXTEIROR SOURCES SHALL NOT EXCEED 45 DB IN ANY HABITABLE ROOM. THE NOISE METIC SHALL BE EITHER THE DAY-NIGHT AVERAGE SOUND LEVEL (LDN) OR THE COMMUNITY NOISE EQUIAVLENT LEVEL (CNEL), CONSISTENT WITH THE NOISE ELEMENT OF THE LOCAL GENERAL PLAN.

1207.9.1 WALL AND FLOOR ASSEMBLIES WALL AND FLOOR-CEILING ASSEMBLIES SEPARATING DWELLING UNITS OR GUEST ROOMS FROM EACH OTHER AND FROM PUBLIC OR SERVICE AREAS AS INTERIOR CORRIDORS, GARAGES AND MECHANICAL SPACES SHALL PROVIDE AIRBORNE AND IMPACT SOUND INSULATION FOR WALLS, AND BOTH AIRBORNE AND IMPACT SOUND INSULATION FOR FLOOR-CEILING ASSEMBLIES.

EXCEPTION: IMPACT SOUND INSULATION IS NOT REQUIRED FOR FLOOR-CEILING ASSEMBLIES OVERNONHABITABLE ROOMS OR SPACES NOT DESIGNED TO BE OCCUPIED, SUCH AS GARAGES, MECHANICAL ROOMS OR STORAGEAREAS

CALIFORNIA FIRE CODE 2022

SECTION 1113 EXISTING GROUP R-1 AND GROUP R-2 OCCUPANCIES (SFM)

1113.1 SCOPE THE PROVISIONS OF THIS SECTION ARE INTENDED TO MAINTAIN OR INCREASE THE CURRENT DEGRSS OF PUBLIC SAFETY, HEALTH, AND GENERAL WELFARE IN EXISTING BUILDINGS CLASSIFIED AS GROUP R OCCUPANCIES.

1113.1.1 APPLICATION

IN ACCORDANCE WITH HEALTH AND SAFETY CODE SECTION 13143.2 THE PROVISIONS OF SECTION 1113.2 THROUGH 1113. 12 SHALL ONLY APPLY TO MULTIPLE STORE S TRUCTURES EXISTING ON JANUARY 1, 1975, LET FOR HUMAN HABITATION, INCLUDING, AND LIMITED TO APARTMENT HOUSES, HOTELS, AND MOTELS WHEREIN ROOMS USED FOR SLEEPING ARE LET ABOVE THE GROUND FLOOR.

1113.2 NUMBER OF EXITS

EVERY APARTMENT AND EVERY OTHER SLEEPING ROOM SHALL HAVE ACCESS TO NOT LESS THAN TWO EXITS WHEN THE OCCUPANT LOAD IS 10 OR MORE (EXITS NEED NOT BE DIRECTY FROM THE APARTMENT OR SLEEPING ROOM). A FIRE ESCAPE AS SPECIFIED HEREIN MAY BE USED AS ONE REQUIRED EXIT. SUBJECT TO APPORVAL OF THE AUTHORITY HAVING JURISDICTION, A LADDER DEVICE AS SPECIFIED HEREIN MAY BE USED IN LIEU OF A FIRE ESCAE WHEN THE CONSTRUCTIONI FEATURE OR THE LOCATION OF THE BUILDING ON THE PROPERTY CAUSE THE INSTALLATION OF A FIRE ESCAPE TO BE IMPRACTICAL

1113.3 STAIR CONSTRUCTION

ALL STAIRS SHAL HAVE A MINIMUM RUN OF 9 INCHES (229 MM) AND A MAXIMUM RIZE OF 8 INCHES (203 MM) AND A MINIMUM WIDTH EXCLUSIVE OF HANDRAILS OF 30 INCHES (762 MM). EVERY STAIRWAY SHALL HAVE AT LEAST ONE HANDRAIL. A LANDING HAVING A MINIMUM HORIZONTAL DIMENSION OF 30 INCHES (762 MM) SHALL BE PROVIDED AT EACH POINT OF ACCESS TO THE STAIR WAY.

1206.1 SCOPE

THIS SECTION SHALL APPLY TO COMMON INTERIOR WALLS, PARTITIONS, AND FLOOR/CEILING ASSEMBLIES BETWEEN ADJACENT DWELLING UNITS, AND SLEEPING UNITS OR BETWEEN DEWLLING UNITS AND SLEEPING UNITS AND ADJACENT PUBLIC AREAS. SOUND TRANSMISSION

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.