Total Gross Area: 52,565 SF Program Area: 34,089 SF Floor-Area Ratio: .53 Net to Gross Ratio: 65%
Phase 4.0: Detail Written Statement & Benchmarks
The increased speed of installation on site, improved quality of the assembly, and the ability to work from inside the building offer great advantages for a unitized wall system. A gridded panel configuration allows for different daylighting options for future needs. An internally glazed unit with small panels provides great flexibility to exchange opaque panels for transparent glass depending on future use. The framing and louver shell emphasize the bridging mass while providing additional protection to fully glazed transient spaces, which are also partially shaded by the building massing. Repairs are made easily by the ability to swap out units, and the clips which rest on the load-bearing floors offer the option for the entire mass to be refaced if so desired in the future.
Professor Fannon Comprehensive Design Studio
Comprehensive Design Studio Professor Fannon Phase 4.0: Detail
Laurel Clark John Hayford
John Hayford & Laurel Clark
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Detail 1/32� Site Model Photos
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Detail 1/8� Building Model Photos
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Detail 1/2� Wall Section Model Photos
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Scans From Sketchbook
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Future Scenarios & Strategies Diagram
Professor Fannon Comprehensive Design Studio
Structure Grey Water Hot Water Cold Water Waste Water Electrical Variable Air Volume System
Scale: 1/16” = 1’
STRUCTURE & COMFORT SYSTEMS
Laurel Clark John Hayford
N
Phase 4.0: Details Integrated Systems Diagram
Laurel Clark John Hayford
N
Phase 4.0: Details Comfort Strategy Diagram
Summer Sun Winter Sun Natural Ventillation Green Roof
Professor Fannon Comprehensive Design Studio
Grey Water Hot Water Cold Water Waste Water Electrical Variable Air Volume System
Scale: 1/8” = 1’
ACTIVE AND PASSIVE COMFORT SYSTEMS
Aluminum Framing
Professor Fannon Comprehensive Design Studio
Aluminum Louvers
Laurel Clark John Hayford
Original Site
Phase 4.0: Details Construction Process Diagram
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Peel-away Axonometric Wall Section
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Scale: 1/32” = 1’
SITE PLAN
Phase 4.0: Details Site Plan
N
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Roof & Floor Plans
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Foundation & Floor Plans
NORTH ELEVATION Scale: 1/16” = 1’
SOUTH ELEVATION
EAST ELEVATION
Scale: 1/16” = 1’
Scale: 1/16” = 1’
Laurel Clark John Hayford
WEST ELEVATION
Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Elevations
Scale: 1/16” = 1’
Not to Scale
Laurel Clark John Hayford
Building Section Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Building Section
Laurel Clark John Hayford
Building Section
Not to Scale
Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Building Section
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Perspective Drawings
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Core Section
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Exploded Panel Diagram
Laurel Clark John Hayford
Professor Fannon Comprehensive Design Studio
Phase 4.0: Details Exploded Component Diagram