2021
Portfolio
Long Gia Nguyen
Hello, In this document, I present to you a selection of projects that i have developed throughout my years as an architectural technology student. It is a collection of commercial, residential, and urban design and construction projects. I hope you enjoy my work
l_nguyen85594@fanshaweonline.ca nglong1302@gmail.com 519.319.7042
EDUCATION 1. Advanced Diploma in Architectural Technology
Fanshawe College, London, Ontario
( 2018-Present)
2. Diploma in Interior Design (Present) The Interior Design Institute - Online Education
EXPERIENCE 1. Colbourne & Kembel, Architects Inc. Architectural Technologist Co-op + + + + + +
(1/2020 - 5/2020 ) Kingston, Ontario
Worked on school and residential projects using Revit and AutoCAD Assisted production manager and principal architects with producing architectural design documents Assisted construction manager in the preparations of tender and building permit documents Coordinate with other trade professionals to ensure consistency between technical drawings Site measured for drafting and documentation purposes 3D Rendered
2. Fanshawe College Skill Trade Day Volunteer
(5/2019 ) London, Ontario
+ Answered questions about Fanshawe College + Guided visitors to designated areas + Encouraged participants to explore the college
SOFTWARE SKILLS
Revit AutoCAD SketchUp
Adobe Photoshop Adobe Illustrator Adobe Indesign
INTERESTS
Painting
Drawing
Weight lifting
Twinmotion Lumion
TOWNHOUSE CONDOMINIUM
OCTION-OLD EAST VILLAGE
Architectural Design & Project IV Individual Project- 2020
Urban Environmental Studies Group Project- 2020
ZELLERS RETAIL
OXFORD FAMILY HEALTH CENTRE
Architectural Design & Project III Individual Project- 2019
Architectural Design & Project II Individual Project- 2019
01
Townhouse C
1
Condominum
North Elevation
West Elevation
South Elevation
East Elevation
1 Storey Unit- 1st Floor Plan
2 Storey Unit- 1st and 2nd Floor Plan
Massing- Isometric View
Building Section
Master Plan
Site Plan
Visualization A- 2 Storey Unit- Living Room
Visualization B- 2 Storey Unit- Stair Well
KEY PLAN
BUILDING SETBACK- 6M
℄
℄
1" 25'-02
FUTURE DECK
P.F.
FUTURE DECK
15'-1"
℄
P.F.
16'-6"
℄
1" 29'-42
BUILDING SETBACK -3M
P.F.
P.F.
FUTURE DECK FUTURE DECK
FUTURE DECK
6' WOOD FENCE ( CONT. ALONG SIDE AND REAR PROPERTY) UNIT A 1 STOREY
UNIT B 2 STOREY
STOOP
STOOP
STOOP
UNIT E 2 STOREY (REVERSED)
UNIT D 2 STOREY (REVERSED)
UNIT C 2 STOREY
STOOP
STOOP
INTERLOCKING BRICK DRIVEWAY (TYP.)
4'-0"
20'-0"
4'-0"
20'-4"
EXISTING BUILDING TO BE REMOVED
EXISTING BUILDING TO BE REMOVED
20'-0"
4'-0"
20'-0"
4'-0"
20'-6"
1" 9'-62
9'-0"
M.B. 2
3 77'-0"
9'-
61 2"
2'
-0
"
R1 2'0" NEW 48" CONC. SIDE WALK
R1
EXISTING SIDEWALK TO REMAIN CURB OF NEW 4-LANE ROAD
EXISTING SIDEWALK (TO BE REMOVED FOR ROAD WIDENING)
41'-10" (12.750m)
20'-0"
N.T.S.
FUTURE ROAD WIDENING
℄
66'-0" ( 21.116m)
℄
1" (10.500m) 34'-52
℄
1" (36.000m) 118'-22 ROAD ALLOWANCE (ARTERIAL)
CURB OF EXISTING 2-LANE ROAD
CURB OF EXISTING 2-LANE ROAD
UNIT A 1-STOREY
FUTURE ROAD WIDENING
SLOPE 12:12
12:12
VA LL E
RIDGE
CURB OF NEW 4-LANE ROAD
Y
R3
1
H
SITE PLAN
IP RI E
DG
SCALE: 1"=20'-0"
PROVIDED 2549.9 m² R-5
ZONE: BUILDING CODE CLASSIFICATION
30% MIN.
61.83%
765 m² MIN.
1576.8 m² 3 10.64m
FRONT YARD
8.0m
59'-2"(17.9m)
REAR YARD
6.0m
16'-6"(5.0m)
EAST SIDE SET BACK
3.0m
25'- 21"(7.6m)
WEST SIDE SET BACK
3.0m
15'-1"(4.6m)
SET BACKS:
E RI DG
Y
3 12.0m MAX.
BUILDING HEIGHT
IP
6458ft² (600m²)
H
23.53%
1147.45m² MAX.
E LL VA
PARKING
C 45% MAX.
RIDGE
LANDSCAPE AREA
1
TO BE SPECIFIED ON DRAWING
SITE AREA
LOT COVERAGE
S
12:12 RIDGE
REQUIRED LEGAL DESCRIPTION
SLOPE
SLOPE 12:12
ROOF PLAN 3 SCALE 32 " = 1'-0"
ROOF VENT (PROVIDE 1 SQ. FT FOR EVERY 300 SQ. FT OF INSULATED BUILDING AREA) EXISTING TREE TO BE REMOVED NEW TREE TO BE PLANTED M.B.
COMMUNITY MAILBOX
P.F. PRIVACY FENCE PRIMARY ENTRANCE SECONDARY ENTRANCE
AREA OF WORK
PAINTED LINE L.S.
℄
℄
UNIT B 2-STOREY
Y
℄ UNIT D 2-STOREY ( REVERSED )
UNIT C 2-STOREY
UNIT E 1-STOREY ( REVERSED) RIDGE
℄
SLOPE 12:12
Y LE
L VA
RIDGE
RIDGE
EY
LL
Y LE VA L
SLOPE 12:12
SLOPE 12:12
VA
LE Y
LL EY
RIDGE
VA
RIDGE
SLOPE 4:12
12:12
12:12
SLOPE SLOPE 4:12
SLOPE
E DG RI
RIDGE
12:12 SLOPE
VA L IP H
RIDGE
E DG
VA
RI
EY
LL
EY
IP
LL
ACME'S CLUSTER TOWNHOUSE CONDOMINIUMS
H
VA
EY LL
L VA
EY
VA
Y
LE
LL
E DG RI
VA
DESIGN STUDIO
RIDGE
IP
12:12
RIDGE
12/17/2020 DATE
SLOPE
H
H
Y LE
RI
FINAL SUBMISSION REVISIONS/SUBMISSIONS
12:12
Y
Y LE
IP
E
L
VA
E
DG
DG
LN BY
R
12:12
E LL VA
RI
RIDGE
SLOPE
RIDGE
RIDGE
H
SLOPE 4:12
IP
RI
E DG RI
IP
SLOPE 12:12
G ID
H
SLOPE
EY
LL
Y
H
L VA
EY
LL
SLOPE 12:12
01 No.
E
IP
VA
E LL VA
12:12
VA
SLOPE 12:12
IP
DG E
H
SLOPE
5" EAVESTROUGH ( TYP.)
SLOPE
LIGHT, STANDARD
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
12:12
12:12
12:12
12:12
12:12
12:12
12:12
SITE PLAN AND ROOF PLAN
NOT FOR PERMIT OR CONSTRUCTION WITHOUT SEAL AND ISSUED NOTE
A1
℄
31'-421" UNIT A 1 STOREY UNIT
UNIT C 2 STOREY UNIT 149'-8"
13'-4"
℄
86'-3"
15'-021"
℄
5'-521"
5'-0" x 3'-0"
5'-10"
17'-3"
℄
5'-10"
5'-10"
17'-10"
13'-521"
4'-11"
11'-621"
2'-821" ℄
28'-1121"
UNIT B 2 STOREY UNIT
18'-5" 3'-421"
℄
28'-1121"
15'-821"
B.P. (TYP.)
℄
GALVANIZED WINDOW WELL ( TYP.)
℄
1'-6"
11'-621"
1'-6"
1'-6"
PERIMETER WEEPING TILE
5-'0" x 3'-0"
5'-0" x 3'-0"
5'-1"
61'-421"
10'-3"
16'-10"
11'-621"
10'-0"
℄ 3'-61" ℄ 2
10'-3"
℄
14'-121"
14'-121"
14'-121"
14'-121"
5'-1"
SUMP PUMP Ø2 '-0
3'-4" x 6'-8"
5'-0"
5'-0"
℄
9'-10"
9'-10"
9'-10"
12'-0" x 8" DROP FROM FOUNDATION + SLAB THICKENING
7'-8" 15'-4"
8'-821"
8"
5'-0" 8" 7'-8"
8'-121"
12'-0" x 8" DROP FROM FOUNDATION + SLAB THICKENING
3'-4" x 6'-8"
UNEXCAVATED
9"
UNEXCAVATED
3'-4" x 6'-8"
9"
"
9"
℄
6'-921"
2'-0" UNEXCAVATED
5'-1"
4'-9"
10'-4"
℄
℄ 10'-4"
℄
7'-9" 15'-821"
12'-0" x 8" DROP FROM FOUNDATION + SLAB THICKENING
7'-9" 15-6"
7'-9" 13'-6"
7'-9" 15'-6" 149'-8"
BLOCK FOUNDATION PLAN SCALE: 81"= 1'-0"
TAG
SIZE 18" X 9" 16" X 9" 16"X16"X9"
DESCRIPTION CONTINUOUS STRIP FOOTING CONTINUOUS STRIP FOOTING ISOLATED PAD FOOTING
SUPPORTS 9" C.I.P. FOUNDATION WALL 8" C.I.P. FOUNDATION WALL TELEPOST
℄
8'-8
∅ TELEPOSTS
℄
℄
28'-1121"
31'-421"
UNIT D 2 STOREY UNIT (REVERSED)
UNIT E 1 STOREY UNIT (REVERSED)
13'-4" 5'-10"
℄ 3'-421"
15'-021"
5'-0" x 3'-0"
5'-521"
17'-10"
18'-5"
℄ 4'-11"
1
11'-621"
℄ 2'-82"
13'-521"
15'-821"
℄
11'-621"
1'-6"
℄
5'-0" x 3'-0" 5'-1"
℄ 10'-3"
16'-10"
10'-0"
14'-121"
61'-421"
14'-121"
11'-621"
℄ 3'-61" ℄ 2
℄
5'-1"
6'-921"
4'-9"
10'-4"
℄
℄
8'-121"
5'-0"
9'-10" 12'-0" x 8" DROP FROM FOUNDATION + SLAB THICKENING
7'-9" 27'-8"
UNEXCAVATED
℄ 3'-4" x 6'-8"
5'-0"
8'-821"
9'-10"
821"
UNEXCAVATED
2'-0"
9"
9"
3'-4" x 6'-8"
℄
7'-9" 15'-6"
12'-0" x 8" DROP FROM FOUNDATION + SLAB THICKENING
7'-8" 15'-821"
7'-8" 15'-4"
01 No.
LN BY
FINAL SUBMISSION REVISIONS/SUBMISSIONS
12/17/2020 DATE
DESIGN STUDIO ACME'S CLUSTER TOWNHOUSE CONDOMINIUMS
BLOCK FOUNDATION PLAN
NOT FOR PERMIT OR CONSTRUCTION WITHOUT SEAL AND ISSUED NOTE
A2
31'-421"
℄
18'-421" 3'-421"
13' 15'-0"
℄
GALVANIZED WINDOW WELL
B.P. (TYP.) W150 X 22
17'-4"
6'-121"
2X10@ 16" O.C.
8"
17'-021"
2X10 @ 16" O.C.
C.I.P. CONC.
5'-521"
R-20 BLANKET BATT INSULATION
W150 X 22
B.P. (TYP.)
2X10 @ 16" O.C.
3'-121"
11'-6" DT
℄
UP-14 RISERS @ 7 38"
FURNACE
DT
2X10 @ 16" O.C.
HEADER
℄ 3'-121"
HWH
℄
W150 X 22
6'-9"
W150 X 22
61'-421"
61'-6"
DT
2X10 @ 16" O.C.
DT
11'-6"
DOUBLE JOIST LOOK OUT JOIST CANTILEVER WALL ABOVE
2X10 @ 16" O.C.
HEADER
℄
W150 X 22
16'-021"
9"
31'-2"
6'-10"
2X10 @ 16" O.C.
14'-8"
4'-9"
2X10 @ 16" O.C.
W150 X 22
℄
15'-821" 5'
2'-3"
8'-121"
8"
C.I.P. CONC.
12'-0" x 8" DROP FROM FOUNDATION + SLAB THICKENING
7'-8"
7'-8"
℄
16'-021"
15'-4" 31'-421"
1 STOREY- BASEMENT SCALE: 41" = 1'-0"
℄
∅ TELEPOSTS
℄
31'-10" 18'-6"
℄
2'-11"
4'-421"
℄
13'-4" 4'-421"
℄
℄
℄
2'-11"
7'-1021"
1'-1121"
5'-521"
℄
2'-9"
1'-1121"
2'-9"
5'-2"
5'-6"
DN
4'-4"
8"
1'-3"
HARDWOOD
13'-021"
17'-5"
13'-121"
24'-9"
PRE-ENGINEERED ROOF TRUSS
HARDWOOD
3'-0"
4'-1"
2'-1121"
5'-7"
4'-7"
C.T.
9'-421"
DN-14 RISERS @ 7 38"
2'-621"
HARDWOOD TRAY CEILING
2'-921"
C.T.
C.T.
10'-121"
321"
3'-1021"
3'-2"
12'-10"
5'-421"
4'-521"
D/W
2'-521"
2'-621"
C.T.
C.T.
5'-621"
1'-0" 5'-421"
13'-621"
6'-421"
10'-3"
HARD WOOD
3'-1021"
9'-521"
1121"
2'-421"
3'-921"
UP
14'-621"
01 No.
LN BY
FINAL SUBMISSION REVISIONS/SUBMISSIONS
12/17/2020 DATE
C.I.P. CONCRETE
5'-921"
20'-1"
PROVIDE 2% SLOPE MINIMUM
C.I.P. CONCRETE
DESIGN STUDIO
13'-921"
UP
7'-821"
7'-821" 15'-5"
ACME'S CLUSTER TOWNHOUSE CONDOMINIUMS
1'-1021"
℄
2'-10"
℄
℄
UNIT PLANS- 1 STOREY UNIT
7'-021"
3'-11" 15'-8"
℄
31'-1"
℄
1 STOREY- GROUND FLOOR SCALE: 41" = 1'-0"
NOT FOR PERMIT OR CONSTRUCTION WITHOUT SEAL AND ISSUED NOTE
A3
℄
℄
FUTURE DECK
29'-7"
28'-7" 10'-9"
11'-921"
17'-10" 5'-10"
4'-11"
5'-1021"
17'-921" 5'-1021"
℄
2'-721"
℄
℄
4'-9"
℄
2'-9"
1'-6" 2'-921"
1'-6"
1'-6"
GALVANIZED WINDOW WELL
B.P. (TYP.)
HARDWOOD TRAY CEILING
2X10 @ 16" O.C. W150x22
2X10 @ 16" O.C.
2X12 @ 16" O.C. 4-2x10 B.U.B.- FLUSH
2X12 @ 16" O.C.
14'-121"
8'-1"
R-20 BLANKET BATT INSULATION 14'-121"
FURNACE 9'-1021"
HARDWOOD
921"
3'-11"
3'-521"
4'-421"
HWH 2'-521"
4-2X10 COLUMN
3'-4"
26'-9"
321" 3'-3"
10'-2"
4-2x10 B.U.B. 2'-521"
5'-421"
5'-421"
321"
W150x22
D/W
5'-4"
SA
44'-3"
C.T.
2X12 @ 16" O.C. 14'-721"
321"
9"
C.I.P. CONCRETE
C.I.P. CON
UP
9'-921"
15'-621"
16'-021"
8"
5'-021"
℄ 20'-621"
4'-921"
UNEXCAVATED
UP
3'-1"
5'-1"
321"
6'-221"
DOUBLE HEADER
C.T.
7'-421"
℄
7'-821"
7'-9"
15'-1"
1'-521"
7'-9"
℄
14'-2"
℄
15'-6" 29'-321"
29'-3"
℄ 2 STOREY- BASEMENT
2 STOREY- GROUND FLOOR
SCALE: 41" = 1'-0"
SCALE: 41" = 1'-0"
3'-521"
3'-9
℄
13'-
∅ TELEPOSTS
℄
℄
29'-7" 11'-921"
3'-6"
6'-2"
℄
4'-7"
℄
2'-121"
2'-10"
6'-1"
4'-2" 4'-021"
5'-121"
11'-0"
3'-2" ℄
℄ C.T.
HARDWOOD
HARDWOOD
7'-9" 2'-5"
W
1'-721"
D
3'-121"
6'-9"
6'-821"
44'-3"
5'-3"
C.T.
13'-2"
4'-0"
5'-221"
5'-1"
4-2x10 B.U.B- FLUSH
2'-6"
3'-1021"
27'-3"
2'-8"
2'-8"
1'-321"
1'-421"
4'-2"
4'-8" 3'-11"
2'-821"
℄
4'-4"
PRE-ENGINEERED ROOF TRUSS
℄
3'-6"
4'-7"
2'-9"
℄
1'-6"
℄
4'-921"
℄
1'-6"
2'-9"
17'-921"
5'-6" ℄
5'-1021"
C.T.
℄
5'-521"
3'-1"
5'-7"
1'-521"
℄
3'-521"
℄
3'-921"
℄
3'-021"
℄
2'-021"
HARDWOOD VAULTED CEILING
01 No.
921"
-921"
15'-921"
15'-6"
NCRETE
3'-021"
℄
LN BY
FINAL SUBMISSION REVISIONS/SUBMISSIONS
12/17/2020 DATE
DESIGN STUDIO
2'-021" 7'-9"
℄
7'-9" 13'-921"
15'-6"
ACME'S CLUSTER TOWNHOUSE CONDOMINIUMS
29'-321" ℄
℄
2 STOREY- 2ND FLOOR
UNIT FLOOR PLANS- 2 STOREY UNIT
SCALE: 41" = 1'-0"
NOT FOR PERMIT OR CONSTRUCTION WITHOUT SEAL AND ISSUED NOTE
A4
12 12 RIDGE LINE BEHIND 1 ATTIC VENT.- 300 OF FREE AREA
ROOF CONSTRUCTION ( TYP. )
U/S OF TRUSS
1'-0" TRAY CEILING
9'-0"
TYPICAL SIDING WALL
FUTURE DECK 3'-0"
TYPICAL 2X10 FLOOR T/O FINISHED FLOOR
8'-7"
GRADE TYPICAL 8" FOUNDATION WALL
TYPICAL BASEMENT FLOOR T/O BASEMENT SLAB
PAD FOOTING
PAD FOOTING
PAD FOOTING
BUILDING SECTION A SCALE: 163 " = 1'-0"
12 12
1'-6" TYPICAL BRICK WALL CANOPY CONSTRUCTION ( TYP. ) 4
12
TYPICAL 2X12 FLOOR
TYPICAL BRICK WALL
GRADE FUTURE DECK
TYPICAL FOUNDATION WALL
BUILDING SECTION B SCALE: 163 " = 1'-0"
TYPICAL 2X12 FLOOR
TYPICAL BASEMENT FLOOR
∅
12 12 RIDGE LINE BEHIND 1'-0"
1'-0" 1 2" GWB
TYPICAL SIDING WALL
2X6 STUDS @ 16" O.C. C/W R-24 FIBERGLASS INSULATION 1 2" GWB PRE-CAST CONC. STEP POURED CONCRETE SLAB (2% SLOPE MINIMUM)
FOUNDATION WALL CUT TO ACCOMMODATE THICKENED SLAB ( 8" BELOW GRADE )
4" GRAVEL
GRADE
TYPICAL 8" FOUNDATION WALL SLAB THICKENED TO 12"
TYPICAL FOUNDATION WALL @GARAGE COMPACTED BACK FILL
12 12 1 ATTIC VENT.- 300 OF FREE AREA
PRE-ENGINEERED ROOF TRUSS ROOF CONSTRUCTION ( TYP. ) U/S OF TRUSS
TYPICAL SIDING WALL
8'-0"
1'-921"
CANOPY CONSTRUCTION ( TYP. ) T/O FINISHED FLOOR
01 No.
1'-121"
LN BY
FINAL SUBMISSION REVISIONS/SUBMISSIONS
12/17/2020 DATE
10'-0"
TYPICAL BRICK WALL
DESIGN STUDIO
T/O FINISHED FLOOR
8'-9"
GRADE
ACME'S CLUSTER TOWNHOUSE CONDOMINIUMS
TYPICAL FOUNDATION WALL T/O BASEMENT SLAB
BUILDING SECTIONS
NOT FOR PERMIT OR CONSTRUCTION WITHOUT SEAL AND ISSUED NOTE
A5
12 12
ASPHALT SHINGLE ROOFING UNDERLAYMENT EAVEPROTECTION 7 16" OSB c/w 'H' CLIP PRE. ENGINEERED ROOF TRUSS @ 24" O.C
1'-5"
PRE-FIN. METAL FLASHING PRE-FIN. METAL GUTTER
VENTED SMOOTH SOFFIT 1'-921"
8'-0" 10'-0"
5 8" MAIBEC WOOD SIDING 1 2" AIR SPACE/ FURRING
R60 6MI 1 2" G
8'-0"
R60 BLOWN-IN CELLULOSE INSULATION 6MIL VAPOUR BARRIER 1 2" GWB
10'-0"
VENTILATED 'L' STRIP c/w FLASHING
1" R-5 EPS BOARD 1 2" OSB BOARD 2X6 STUD c/w R-24 FIBERGLASS INSULATION 6 MIL VAPOUR BARRIER 1 2" GWB
VENTED SMOOTH SOFFIT FOUNDRY ROUND VINYL SHAKE @ GABLE END
ASPHALT SHINGLE ROOFING UNDERLAYMENT EAVE PROTECTION 7 16" OSB BOARD c/w 'H' CLIP ENGINEERED ROOF TRUSS @ 24" O.C.
R-24 FIBERGLASS INSULATION c/w 6MIL VAPOUR BARRIER
VENTED SMOOTH SOFFIT
3-2x8 WOOD BEAM c/w CEDAR WOOD COVER
5 8" SUB-FLOOR 2X12 FLOOR JOIST @ 16" c/w BRIDGING
WEEP VENT
4x4 WOOD COLUMN c/w CEDAR WOOD COVER
1 2" GWB 6 MIL VAPOUR BARRIER 2x6 STUD c/w R-24 FIBERGLASS INSULATION 1 2" OSB BOARD 1" R-5 EPS BOARD 1" AIR SPACE 3.5" BRICK
SLOPED C.I.P. CONCRETE c/w WWM
R-24 FIBERGLASS INSULATION c/w 6MIL VAPOUR BARRIER
5 8" 2X
8'-9"
5 8" SUB-FLOOR 2X12 FLOOR JOIST @ 16" c/w BRIDGING
8'-9"
SILL GASKET
1 2"∅ ANCHOR BOLT @ 8' O.C.
1 2" BOND BREAK
8"
DRAINAGE MAT SPRAY ON DAMP PROOF C.I.P CONCRETE
4"∅ WEEPING TILE c/w GRAVEL
EXTERIOR WALL @ CANOPY SCALE: 21" = 1'-0"
C.I.P CONCRET 4" GRANULAR
DEMI
SCALE: 21" =
12 12
ROOF BEYOND
1'-5"
ASPHALT SHINGLE ROOFING UNDERLAYMENT EAVEPROTECTION 7 16" OSB c/w 'H' CLIP PRE. ENGINEERED ROOF TRUSS @ 24" O.C
1'-11"
0 BLOWN-IN CELLULOSE INSULATION IL VAPOUR BARRIER GWB
5 8" TYPE X GWB
6 MIL VAPOUR BARRIER 2x6 STUD c/w R-24 FIBERGLASS INSULATION 5 8" TYPE X GWB 1 2" OSB BOARD 1" R-5 EPS BOARD 1 2" AIR SPACE/ FURRING 5 8" MAIBEC WOOD SIDING
GABLE TRUSS WALL CAPPED w/ 58" FIRE CODE GWB TWO LAYERS OF 21" FIRE CODE GWB BETWEEN HEADERS WHICH ALSO ACT AS FIRE STOPS R-24 FIBERGLASS INSULATION c/w 6MIL VAPOUR BARRIER
5 8" TYPE X GWB 2X4 STUDS 1" AIR SPACE 2X6 STUDS c/w R-24 FIBERGLASS INSULATION ONE SIDE FOR SOUND TRANSMISSION RATING 2X4 STUDS 5 8" TYPE X GWB
9'-0"
5 8" SUB-FLOOR 2X12 FLOOR JOIST @ 16" c/w BRIDGING
TWO LAYERS OF 21" GWB BETWEEN HEADERS WHICH ALSO ACT AS FIRE STOPS SINGLE RIM JOIST AND BLOCKING AT BOTH SIDES OF WALL TWO LAYERS OF 58" FIRE CODED GWB AT BOTH SIDES OF BLOCKINGS WHICH ACT AS FIRESTOPS R-24 FIBERGLASS INSULATION c/w 6 MIL VAPOUR BARRIER AT BOTH SIDES OF WALL
LN BY
FINAL SUBMISSION REVISIONS/SUBMISSIONS
12/17/2020 DATE
SILL GASKET 1 2"∅ ANCHOR BOLT @ 8' O.C.
SUB-FLOOR X12 FLOOR JOIST @ 16" c/w BRIDGING
ISING WALL
01 No.
DESIGN STUDIO
8'-7"
5 8" SUB-FLOOR 2X10 FLOOR JOIST @ 16" c/w BRIDGING
ACME'S CLUSTER TOWNHOUSE CONDOMINIUMS
8" C.I.P. FOUNDATION WALL
WALL SECTIONS
C.I.P CONCRET 4" GRANULAR
= 1'-0" NOT FOR PERMIT OR CONSTRUCTION WITHOUT SEAL AND ISSUED NOTE
A6
℄
℄
UNIT A 1-STOREY
12
℄
UNIT B 2-STOREY
UNIT C 2-STOREY
12 ASPHALT SHINGLE
12 12 12
12 12
12
1" 1'-92
12
12
12
12
12
12
12
12
SIDING
1'-6"
1" 1'-92
SIDING
BRICK
9'-0"
1'-10" 1'-6"
SIDING
12
1" 1'-92
1" 1'-92
S.C.B. U/S OF TRUSS ( 1 STOREY )
12
12
12
SIDING
ASPHALT SHINGLE
12
12
12
12
8'-7"
GRADE
8"
8"
T/O FLOOR ( 1 STOREY )
C.I.P. CONCRETE STOOP PRE-CAST CONCRETE STEP
PRIVACY WALL
T/O BASEMENT SLAB
SOUTH ELEVATION
SCALE 81" = 1'-0"
℄ UNIT E 1-STOREY ( REVERSED)
℄ UNIT D 2-STOREY ( REVERSED )
℄ UNIT C 2-STOREY
12 12
12 12
12
12
12
12
1'-6"
12
9'-0"
12
12
S.C.B.
12
U/S OF TRUSS ( 1 STOREY )
12
12
12
1 1'-6"
1'-6"
1'-11"
1'-6"
1'-6"
1'-10" 1'-6"
SONO TUBE (TYP.) PRE-CAST CONC. STEPS (TYP.)
T/O BASEMENT SLAB
8"
8'-7"
GRADE
8"
T/O FLOOR ( 1 STOREY )
GALVANIZED WINDOW WELL (TYP.)
NORTH ELEVATION SCALE 81" = 1'-0"
12
12
12
12
12
12
12
12
1'-0"
U/S OF TRUSS ( 1 STOREY )
1'-0"
8"
T/O BASEMENT SLAB
WEST ELEVATION SCALE 81" = 1'-0"
SIDING
T/O FLOOR (2 STOREY)
T/O FLOOR (2 STO
GRADE
GRA
8'-9"
8"
8'-7"
T/O FLOOR (2 STO
1'-0"
T/O FLOOR ( 1 STOREY ) GRADE
T/O FLOOR (2 STOREY)
10'-0"
9'-0"
8"
U/S OF TRUSS (2 ST
8'-0"
U/S OF TRUSS (2 STOREY)
T/O BASEMENT SLAB
T/O BASEMENT
EAST ELEVATION SCALE 81" = 1'-0"
℄ UNIT D 2-STOREY ( REVERSED )
UNIT E 1-STOREY ( REVERSED)
ASPHALT SHINGLE U/S OF TRUSS (2 STOREY) 1" 1'-92
8'-0"
12 12
1" 1'-92
12 12
T/O FLOOR (2 STOREY)
S.C.B. SIDING
SIDING
1'-6"
1'-10"
1'-6"
10'-0"
BRICK
8"
T/O FLOOR (2 STOREY) GRADE
8'-9"
C.I.P. CONCRETE STOOP PRE-CAST CONCRETE STEP
T/O BASEMENT SLAB
℄ UNIT B 2-STOREY
UNIT A 1-STOREY 12 12
12
12
12
12
S.C.B.
12
12
12
12
U/S OF TRUSS (2 STOREY)
1'-6"
12
1'-11"
8'-0"
12
12
T/O FLOOR (2 STOREY) 1'-6"
1'-10" 1'-6" 10'-0"
1'-6"
SONO TUBE (TYP.)
GRADE
8'-9"
8"
T/O FLOOR (2 STOREY)
GALVANIZED WINDOW WELL (TYP.)
12
T/O BASEMENT SLAB
01 No.
12
12
12
12
FINAL SUBMISSION REVISIONS/SUBMISSIONS
12/17/2020 DATE
12
12
12
DESIGN STUDIO 8'-0"
TOREY) 1'-0"
OREY)
U/S OF TRUSS ( 1 STOREY ) 1'-0" SIDING
OREY)
8'-7"
8'-9"
8"
T/O FLOOR ( 1 STOREY )
ADE
ACME'S CLUSTER TOWNHOUSE CONDOMINIUMS
8" 9'-0"
8"
10'-0"
1'-0"
SLAB
LN BY
ELEVATIONS
GRADE
T/O BASEMENT SLAB
NOT FOR PERMIT OR CONSTRUCTION WITHOUT SEAL AND ISSUED NOTE
A7
3'-3"
1 2" SQUARE STEEL TUBE GUARD RAIL- BEZDAN FASTENED TO FLOOR
T/O FLOOR
3"
3'-9"
3'-9"
10'-0"
LEDGER BOARD
1 2" SQUARE STEEL TUBE GUARD RAIL- BEZDAN FASTENED TO TREADS
7'-5" HEADROOM CLEARANCE
T/O FLOOR
LEDGER BOARD 8'-9"
KNEE WALL
KNEE WALL T/O BASEMENT SLAB
STAIR SECTION- 2 STOREY UNIT SCALE: 21" = 1'-0"
∅ TELEPOST
2'-6" 3 TREADS @ 10"
STEEL BEAMS ARE TO BE W150x22
3'-5" LANDING WIDTH
3'-5" LANDING WIDTH
2'-6" 3 TREADS @ 10"
6.
DN- 16 RISERS @ 7.5"
3'-721" LANDING WIDTH
3'-721" LANDING WIDTH
5'-10" 7 TREADS @ 10"
STAIR PLAN DETAIL- 2 STOREY UNIT- 2ND FLOOR
2'-1121" LANDING WIDTH
DN- 14 RISERS @ 7.5"
UP- 16 RISERS @ 7.5"
321"
3'-5" LANDING WIDTH
521"
1'-8" 2 TREADS @ 10"
2'-6" 3 TREADS @ 10"
SCALE: 21" = 1'-0"
3'-721" LANDING WIDTH
5'-10" 7 TREADS @ 10"
5'-10" 7 TREADS @ 10"
3'-721" LANDING WIDTH
STAIR PLAN DETAIL- 2 STOREY UINT-GROUND FLOOR
1'-8" 521" 2 TREADS @ 10" 2'-10" LANDING WIDTH
2'-10" LANDING WIDTH
1'-8" 521" 2 TREADS @ 10"
SCALE: 21" = 1'-0"
UP- 14 RISERS @ 7.5"
2'-1121" LANDING WIDTH
6"
5'-10" 10 TREADS @ 10"
STAIR PLAN DETAIL- 2 STOREY UNIT- BASEMENT SCALE: 21" = 1'-0"
3'-721" LANDING WIDTH
01 No.
LN BY
FINAL SUBMISSION REVISIONS/SUBMISSIONS
12/17/2020 DATE
DESIGN STUDIO ACME'S CLUSTER TOWNHOUSE CONDOMINIUMS
STAIR PLANS AND SECTION
NOT FOR PERMIT OR CONSTRUCTION WITHOUT SEAL AND ISSUED NOTE
A8
TAG WIDTH HEIGHT 2'-0"
4'- 21"
2'-0"
5'-9"
2'-0"
7'-1"
2'-0"
8'-0"
2'-8"
4'-2"
3'-2"
4'-2"
2'-4"
7'-10"
2'-0"
4'- 21"
9'-7"
6'-1"
5'-0"
3'-0"
6'-0"
6'-0"
8'-2"
6'-2"
9'-2"
6'-2"
10'-2"
5'-1"
1'-4"
4'-4"
DESCRIPTION MARVIN ULTIMATE DIRECT GLAZE WOOD WINDOW MARVIN ULTIMATE DIRECT GLAZE WOOD WINDOW MARVIN ULTIMATE DIRECT GLAZE WOOD WINDOW MARVIN ULTIMATE DIRECT GLAZE WOOD WINDOW MARVIN ULTIMATE DOUBLE HUNG WOOD WINDOW MARVIN ULTIMATE DOUBLE HUNG WOOD WINDOW MARVIN ULTIMATE DOUBLE HUNG WOOD WINDOW MARVIN ULTIMATE IN SWING WOOD WINDOW MARVIN ULTIMATE BAY WOOD WINDOW MARVIN ULTIMATE GLIDER- 2 SASH WOOD WINDOW MARVIN ULTIMATE GLIDER- 3 SASH WOOD WINDOW MARVIN ULTIMATE GLIDER- 3 SASH WOOD WINDOW MARVIN ULTIMATE GLIDER- 3 SASH WOOD WINDOW MARVIN ULTIMATE POLYGON WOOD WINDOW P3-5 LOUVER
MASONRY WALL LINTEL
SIDING WALL LINTEL 2-2X4
2-2X4 c/w 341"x341"x41" LOOSE LINTEL 2-2X4 c/w 341"x341"x41" LOOSE LINTEL 2-2X4 c/w 341"x341"x41" LOOSE LINTEL 2-2X4 c/w 341"x341"x41" LOOSE LINTEL 2-2X4 c/w 341"x341"x41" LOOSE LINTEL
2-2X4
TAG WIDTH HEIGHT
DESCRIPTION
3'-2"
7'-1"
PELLA WOOD ENTRY DOOR
3'-6"
7'-1"
PELLA WOOD ENTRY DOOR
3'-4"
6'-8"
MARVIN SLIDING FRENCH DOOR
5'-3"
8'-1"
MARVIN SLIDING PATIO DOOR
9'-2"
8'-4"
MARVIN 3-PANEL SLIDING PATIO DOOR w/ DG TRANSOM GARAGA GARAGE DOOR
MASONRY WALL LINTEL 2-2X6 c/w 341"x341"x41" LOOSE LINTEL 2-2X6 c/w 341"x341"x41" LOOSE LINTEL
2-2x10 c/w 341"x341"x41" LOOSE LINTEL PRE-ENGINEERED
12'-0"
8'-0"
2-2X4
2'-4"
7'-4"
2-2X4
2'-8"
7'-4"
N/A
N/A
2'-10"
7'-4"
MARVIN- TRUSTILE INTERIOR DOOR MARVIN- TRUSTILE INTERIOR DOOR MARVIN- TRUSTILE INTERIOR DOOR
DOUBLE RIM JOIST
DOUBLE RIM JOIST
4'-6 21"
7'-4"
INTERIOR WOOD SLING DOOR
N/A
PRE-ENGINEERED
4'-8 21"
7'-4"
INTERIOR WOOD SLING DOOR
N/A
5'-6"
7'-4"
INTERIOR WOOD SLING DOOR
N/A
5'-10"
7'-4"
INTERIOR WOOD SLING DOOR
N/A
6'-8 21"
7'-4"
INTERIOR WOOD SLING DOOR
N/A
3'-0"
6'-8"
PRE-HUNG DOOR
N/A
PRE-ENGINEERED PRE-ENGINEERED PRE-ENGINEERED N/A
N/A
N/A N/A N/A
SIDING WALL LINTEL
TAG
SIZE 18" X 9"
DESCRIPTION
SUPPORTS
CONTINUOUS STRIP FOOTING
9" C.I.P. FOUNDATION WALL
16" X 9"
CONTINUOUS STRIP FOOTING
8" C.I.P. FOUNDATION WALL
16"X16"X9"
ISOLATED PAD FOOTING
TELEPOST
2-2X6 WOOD LINTEL
PRE-ENGINEERED N/A N/A N/A N/A N/A N/A N/A N/A N/A
01 No.
LN BY
FINAL SUBMISSION REVISIONS/SUBMISSIONS
12/17/2020 DATE
DESIGN STUDIO ACME'S CLUSTER TOWNHOUSE CONDOMINIUMS
SCHEDULES
NOT FOR PERMIT OR CONSTRUCTION WITHOUT SEAL AND ISSUED NOTE
A9
02
Old E
Oction East Village
Our visions:
The objectives of this project are:
The goals are to:
Oction will be a safe, sustainable, resource independent developement by providing mixed income housing with access to local shops, basic needs, rapid transportation, and mixed creation.
Incorporate transit oriented development principles in the design of the site, as well as providing mixed income housing and create a sense of community, while incorporating sustainable construction and sustainable building systems, and encourage access to local shops, recreation, and basic needs.
Old East Village
Sun Diagram
Visualization A- Plaza
Create a strong pedestrian connection between the transit stop and development by including multiple walkways to stops Place building close to street/ walkways to encourage foot traffic with access to buildings from all four roads surrounding the development Redirect savings from utilities to lower the cost of housing, making it more affordable for more demographics Provide indoor common areas such as community centre in residential developments to encourage interaction between residents Incorporate systems such as rain collection systems, green energy systems and natural light where possible to create a resource independent development Use local material and high efficiency systems such as windows, appliances, heating/cooling systems and higher insulation standards Resolve food desert crisis by providing grocery store on site Incorporate a variety of commercial space sizes with focus on smaller units to provide opportunity for existing and new local business
Visualization B- Dundas Street
Visualization C- Highrise Building
Massing- Isometric View
03
3
NORTH ELEVATION
EAST ELEVATION
SOUTH ELEVATION
WEST ELEVATION
OPEN TO BELOW
GROUND FLOOR
SECOND FLOOR
Zellers was a Canadian chain discount department retailer that was based in Brampton, Ontario. It was founded in 1931 and was acquired by Hudson’s Bay Company (HBC) in 1978. A series of acquisitions and expansions allowed Zellers to reach its peak in the 1990s, with 350 stores across the country in 1999. However, fierce competition by Walmart Canada and an inability to adjust to the increasingly volatile retailing industry resulted in Zellers losing significant ground in the 2000s. The project is a tribute to the retail chain, and a proposal for any future retail/ grocery store to the site, to solve the food desert crisis occurring in Old East Village Neighborhood.
THE CONSORTIUM | ZELLE
WALL TYPE LEGEND
SHEET INDEX
SCALE 1:20 X
Y
CVR-COVER SHEET
Z
A101-SITE PLAN EW1 ARHCITECTURAL BLOCK
EW2A COMPOSITE METAL PANEL
EW2B COMPOSITE METAL PANEL
90 ARCH. BLOCK 60 AIR SPACE 50 POLYURETHANE SPRAY FOAM INSULATION 190 CONC. BLOCK
51 METAL PANEL 50 AIR SPACE 50 POLYURETHANE SPRAY FOAM INSULATION 190 CONC. BLOCK
51 METAL PANEL 150 AIR SPACE
325
A201-GROUND FLOOR PLAN A202-SECOND FLOOR PLAN
50 POLYURETHANE SPRAY FOAM INSULATION 190 CONC. BLOCK
276
65
376
65
65
441
341
390
A203-FOUNDATION PLAN A302-SOUTH & WEST ELEVATIONS A401-WALL SECTIONS
A
EW3A CURTAIN WALL
A402-ENLARGED STAIR PLANS & S
EW4 RETAINING WALL
190 CURTAINWALL
A301-NORTH & EAST ELEVATIONS
A403-STAIR DETAL
300 POURED CONCRETE
A501-PLAN & SECTION DETAILS 190
A502-PLAN & SECTION DETAILS
300
340
P1B MEAL STUD w/ GYPSUM
P1C FURRING w/ GYPSUM
13 GYPSUM BOARD 92 METAL STUD @400 O.C 13 GYPSUM BOARD
P2A CONCRETE BLOCK
23METAL FURRING CHANNEL @400 O.C 13 GYPSUM BOARD
118
P2B CONCRETE BLOCK
190 CONC. BLOCK
36
140 CONC. BLOCK
190
140
ERS RETAIL COMPANY
SECTION
ZELLERS RETAIL COMPANY LONDON CANADA
CONTRACTOR NOTE:
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
NOTES:
VICINITY MAP
inspire
ARCHITECTURE
PRELIMINARY NOT FOR CONSTRUCTION DATE:
ABBREVIATIONS ALUM.: ALUMINUM ARCH.: ARCHITECTURAL B.F: BARRIER FREE
2019/12/13
DRAWN BY:
L,NGUYEN
CHECK BY:
NGUYEN & CASTILLO
PROJECT NO.:
19-03
CONC. : CONCRETE C/W : COMPLETED WITH CMP. : COMPOSITE METAL PANEL DWGS.: DRAWINGS ELEV.: ELEVATION FDN.: FOUNDATION F.R.: FIRE ROUTE F.A.D.S.: FACILITIES ACCESSIBILITY DESIGN STANDARDS HDWD: HARD WOOD L.M.: LIMITED MOBILITY T/O: TOP OF TERR: TERRAZO TYP.: TYPICAL VCT: VINYL COMPOSITE TILE
A
FINAL_SUBMISSION
NO.
REVISION
DRAWING TITLE:
COVER SHEET
O.B.C.: ONTARIO BUILDING CODE PRE FIN.: PRE FINISHED S.O.G.: SLAB ON GRADE STRUCT.: STRUCTURAL
SHEET NO:
CVR
2019/12/13 DATE
N19°36'25''W 102000
8000 6500 1500
BUILDING SET BACK
3000
N68°
PARKING SET BACK
BUILDING SETBACK
23489
PARKING SET BACK
2000
PROPERTY LINE
PROPERTY LINE
EXISTING CONC. CURB 11813 NEW CONC. CURB
WOOD FENCE TYP.
5000 8000
6000
00 R60
15
R9
1194
915
11
5500 7500 5500
10
3000
7
3210
7
+251.748
12
13
14
15
4800 20
21
22
23
7500
5 OW R91 HIS R RT O F P.
TY
28800 9 STALLS@2700
3210
25
26
27
28
29
35
36
37
38
915
24
915
19
5500
18
3304
17
3210
5500
1500 5454
16
TY
30
31
32
33
39
40
41
42
7500
F.R.
1200 34
W P. TY
150 CONC. CURB
5
R91
8000
1064
R
EXISTING ELECTRICAL POLE TYP.
1192
50
0
2000
R6
F.R.
00
0
1229
00
R6 1200
6000
6125
7336
6000
1200
35
SIGHT TRIANGLE
EXISTING SIDE WALK EXISTING BOULEVARD
200
4500
ASPHALT PAVING
915
450 PAINTED PARKING LINE TYP.
R1
T
6 FIRE
915
FO R91 RT 5 HI SR O
00 OW R45 HIS R RT
FO YP.
7500
4500
3715
11994
9
F.R.
6
5500
15800 1500
8
1500
OW 00 R45 THIS R R O P. F
0 450
5 11033
F.R.
4500
7500
4
915 5140
8454
7
1200
5500
13025
3
19350 6 STALLS @ 2700
28800 9 STALLS @ 2700
3210
GRASS COVER
16336
2
1935
1200
1200 4500
.
7500
EXISTING CONC. CURB
McCORMICK BLVD
15420
1
915
YP
0T
50
R4
7800
6 GRASS COVER
15
+251.898
15295
4123
R9
EXISTING SIDE WALK EXISTING BOULEVARD
6574
573 R11 P. TY
1050
0
PAINTED PATH TYP.
TYP. CONC. WALK WAY c/w CONTROL JOINTS
11573
00
7667
915
F.R.
6000
11598
7985
6000 F.R.
NEW SIDE WALK c/w CONTROL JOINTS
8000
F.R.
6000
19795
98860
R6
NEW DEPRESSED CONC. CURB c/w ASPHALT INFILL TO EXISTING MUNICIPAL ROADWAY
6000
0
20
R1
31350
NEW DEPRESSED CONC. CURB c/w ASPHAL TO EXISTING MUNICIPAL ROADWAY
DUNDAS STREET N
SITE PLAN SCALE 1:300
ZONING BY-LAW INFORMATION CHART ALLOWABLE LOT AREA LANDSCAPE COVERAGE HEIGHT PARKING
10%MIN
1289.52M2
30%MAX
3868.54M2
9M
RETAIL : 1/30M2 OFFICE:1/40M2 CAFE:1/10M2 WAREHOUSE: 1/200M2 2 B.F. 2 L.M.
PROVIDED 12895.14M2
4421M2
34.28% 10.52%
RETAIL : 20 OFFICE:13 CAFE:12 WAREHOUSE: 3
9.65M
1356.9M2 42 STANDARD STALLS 3 B.F. 3 L.M.
°44'21''E 126423
R9
915
915
915
15
15
915
GRASS COVER
4500
4500
+251.898
R1
5 R4
13917
LONDON CANADA
0
4500
50
4500
00
GRASS COVER
R4 4500
F.R.
CONTRACTOR NOTE:
915 3200 3200
3200
7500
ZELLERS RETAIL COMPANY
0
TYP. CONC. WALK WAY c/w CONTROL JOINTS
4500
7764 R915
R4
11961
150 NEW CONC. CURB TYP.
ASPHALT PAVING
915
11082
50
0
0 25
6575
5500
3075 L.M.
43 5500
30680
10468
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
10982
+251.898
L.M.
44
L.M.
45
RETAINING WALL AND GUARD RAIL
11530
NOTES:
PROPERTY INFORMATION:
48
LT INFILL
915 915
BUILDING SETBACK
BUILDING TYPE : COMMERCIAL No. OF STOREYS :2 BGA: 1356.9M2
B.F. 3075
2000
2700
47 5500
B.F. B.F. PAINTED LINE
N19°36'25''W 102000
PROPERTY LINE
2000
1500
5500
R915
LOT NUMBER:
030060119000000
REGISTERED PLAN NUMBER:
494PT BLK EBLKF LOTS PART 2
ADDRESS:
1156 DUNDAS ST. LONDON, ONTARIO MIDDLESEX COUNTRY
LEGENDS: B.F. MAIN ENTRANCE EGRESS RECEIVING ENTRY FREE STANDING SIGNAGE
10499
BOLLARD BARRIER FREE SIGN
18100
CONC. PARKING CURB EXISTING DECIDUOUS TREE NEW DECIDUOUS TREE
20200
6000
PROPERTY LINE
B.F. CURB RAMP
8000
5000
NEW SHRUBS GRASS COVER
PARKING SET BACK
3000
NEW WALK WAY c/w CONTROL JOINTS F.R. 6000
8000
BUIDLING SET BACK
R600 0
6000 ROUTE
3000
TRUCK LANDING
B.F.
46
PARKING SET BACK
2700
2000
18000
GRASS COVER
2700
0
R9
N68°44'21''E 126423
inspire
REMOVE EXISTING CURB TYP.
25905 EXISTING CONC. CURB
ARCHITECTURE
14541
NEW CONC. CURB c/w ASPHALT INFILL TO EXISTING MUNICIPAL ROADWAY
PRELIMINARY NOT FOR CONSTRUCTION DATE:
2019/12/13
DRAWN BY:
LN, NGUYEN
CHECK BY:
CASTILLO
PROJECT NO.:
19-03
B
FINAL SUBMISSION
2019/12/13
A
ISSUED FOR REVIEW
2019/11/13
NO.
REVISION
DRAWING TITLE:
SITE PLAN
SHEET NO:
A101
DATE
B
A
C
10000
10000
1 40716
18000
1
341
2124
10000
341
1200
10000
9900
3100
1000
1
3000
3100
RECEIV 2 A402
441
441
1500
A A402
2
STAIRWELL 106
BN
2650
7285
9985
9
12035 12035
CANOPY ROOF ABOVE
1100 M.O.
405
12100
5700
4876
BN
1hr F.R.R.
3
7100
RETAIL 105 19900
CANOPY ROOF ABOVE
40616
B A401
BN
BN
BN
WAREHOU 113 STORE MANAGER OFFICE 107
7875
6000
30716
3550
C01
CANOPY ROOF ABOVE
3550
24740
STAIRWELL 104
U.T.R. 110
U.T.R. 115 1102
405
40 Ø24 .S. F.A.D
6165
5259 10605
3935
3150
BN
885
BN
Ø2440 F.A.D.S.
LOBBY 102
10000
0 44 Ø2 .D.S. F.A
1600
2795
3815
BN
BN
BN
620
620
5x 4330
N
32150
4200 M.O
3680
A
620 CANOPY ROOF ABOVE
620
2310
405
325
405
5
2100
VESTIBULE 101
CARTS AREA BN
BN
510
BN
6000
6035
8 A502
ELEVATOR 103
3210
BN
JAN 11
40 Ø24 .S. F.A.D 3580
2100
4
3955
1430
TRAINING & LUNCH ROOM 109
3910
11900
3791
CASH OFFICE 108
40680
4820
Ax
1500
Bx
10000
B
GROUND FLOOR PLAN SCALE 1:100
1
C
Dx
D
10000
Ex
2800
E
3400
10492
3800 10100
3674
5326
1100 M.O.
1
9810
ZELLERS RETAIL COMPANY
8016
BN
10001
10001
341
LONDON CANADA
VING AREA 119 620
620
CANOPY ROOF ABOVE
BN
1984
620
620
2x
2
3579
4 A501
MECHANICAL ELECTRICAL 114
A A401 441
6450
9890
CONTRACTOR NOTE:
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
3610
40616
13890
12000
NOTES:
3
3400 30615
1100 M.O.
LOGISTIC OFFICE 118 4850
3200
ARCHITECTURE
C A401
4960
I.T. ROOM 117
5400
441
2920 BN
BN
NOT FOR CONSTRUCTION
3 A501
U.T.R. 112
DATE:
6029
CAFE 111
4585
2019/12/013
DRAWN BY:
L,NGUYEN
BN
6005
PRELIMINARY
4
6000
NITOR 16
inspire
8190
9596
CANOPY ROOF ABOVE
310
BN
BN
USE
CHECK BY:
NGUYEN & CASTILLO
PROJECT NO.:
BN
405
5 5 A501
10000
10000
19-03
6 A501 B
FINAL
A
ISSUED FOR REVIEW
NO.
SUBMISSION
REVISION
DRAWING TITLE:
D
E
2019/12/13 2019/12/04 DATE
GROUND FLOOR PLAN SHEET NO:
A201
A
B
C
1
A A402 10000
LOW ROOF BELOW 10000
10000
40616
1000
2055
200
1200 M.O.
1200 M.O.
200
1200 M.O.
200
1200 M.O.
200
1000
1200 M.O.
1200 M.O.
200
1200 M.O.
200
1200 M.O.
200
1200 M.O.
200
200
1600 M.O.
10410
1800 M.O.
441
1 A402
441
2 2650
BN
BN
BN
BN
STAIRWELL 106
4060
4650
BN
4250
BN
C02
3340
3320
I.T. ROOM 212
4050
500 Ø1 .C. O.B
5245
WAITING AREA 203
5090
STAIRWELL 104
RECEPTION 202 5259
CONFERENCE ROOM 204 BN
ELEVATOR 103
BN
BN
BN
405
4
MEN'S WASHROOM 215
8795
591
4470
405
BN
CANOPY ROOF BELOW
1093
11900
4370
EXECUTIVE OFFICE 205
2745
3940
COPIER 213
3940
5470
BN
500 Ø1 .C. O.B
BN
30680
BN
JANITOR 211 4470
405
WOMEN'S WASHROOM 214
3880
4460
BN
HUMAN RESOURCE 207
FINANCIAL OFFICE 206
CANOPY ROOF BELOW
24680
B A401
OPE
LOBBY 201
BN
3000
12100
CANOPY ROOF BELOW
6080
5700
LUNCH ROOM 210
OFFICE AREA 209
1hr F.R.R.
3
BN
13225
405
6000
OPEN TO BELOW
2935
6000
30 DIA. STEEL GUARDRAIL. PAINTED LOW ROOF BELOW
BN
BN
405
5 CANOPY ROOF BELOW
10000
10680 40716
10000
A
N
10000
B
SECOND FLOOR PLAN SCALE 1:100
10000
C
D
E
1
ZELLERS RETAIL COMPANY
10000
LONDON CANADA
10151
CANOPY ROOF BELOW
2
BN
CONTRACTOR NOTE:
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
A A401
NOTES:
24651
12000
EN TO BELOW
BN
3
12000
30615
CANOPY ROOF BELOW
BN
inspire
C A401
ARCHITECTURE
BN
PRELIMINARY
4
NOT FOR CONSTRUCTION
DATE:
2019/12/13
6000
5964
LOW ROOF BELOW
DRAWN BY:
L,NGUYEN
CHECK BY:
NGUYEN & CASTILLO
5
19950
PROJECT NO.:
19-03
B
FINAL
A
ISSUED FOR REVIEW
NO.
10000
D
SUBMISSION
REVISION
DRAWING TITLE:
E
2019/12/13 2019/12/04 DATE
SECOND FLOOR PLAN SHEET NO:
A202
1
2
3
10000
10000 41370
20000
1475
A
1200
NOTC TO A OPEN
3100
10000
10000
3100
NOTC TO A OPEN
1125
T N
B 766 4120
15925
6756
COUNTINUOSLY POURED CONCRETE FOUNDATION WALL
NOTCH AT FDN. WALL TO ACCEPT S.O.G. AT BARRIER FREE OPENING
41370
1100
12100
COUNTINUOSLY POURED CONCRETE FOOTING
NOTCH AT FDN. WALL TO ACCEPT S.O.G. AT BARRIER FREE OPENING
EXTERIOR CONCRETE PAD FOOTING CONCRETE PIER
INTERIOR CO CONCRETE PIE
TYP. STEEL COLUMN REFER TO STRUCT. DWGS.
TYP. STEEL CO REFER TO STRU
11900
31370
C
CONTINUOSLY POURED CONCRETE FOOTING
23514
COUNTINUOSLY POURED CONCRETE FOUNDATION WALL
CONTINUOSLY POURED CONCRETE FOOTING COUNTINUOSLY POURED CONCRETE FOUNDATION WALL 876
15350
1764
3443
2931
D
21635
6000
883
NOTCH AT FDN. WALL TO ACCEPT S.O.G. AT BARRIER FREE OPENING
3815
COUNTINUOSLY POURED CONCRETE FOUNDATION WALL
2310
E
Ex
4676
4200
41370
4
5
10000
10000
11370
10000
11370
3266
1100
5634
ZELLERS RETAIL COMPANY
CH AT FDN. WALL ACCEPT S.O.G. AT NING
LONDON CANADA
COUNTINUOSLY POURED CONCRETE FOUNDATION WALL
THICKENED SLAB BELOW N.B.L. CONC. BLOCK WALLS
CONTRACTOR NOTE:
COUNTINUOSLY POURED CONCRETE FOOTING
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
NOTCH AT FDN. WALL TO ACCEPT S.O.G. AT BARRIER FREE OPENING
681
CH AT FDN. WALL ACCEPT S.O.G. AT NING
NOTES:
3612
5920
960
THICKENED SLAB BELOW N.B.L. CONC. BLOCK WALLS
14300
3235
9888
ONCRETE PAD FOOTING ER
31370
20285
830
OLUMN UCT. DWGS.
inspire
NOTCH AT FDN. WALL TO ACCEPT S.O.G. AT BARRIER FREE OPENING
ARCHITECTURE
THICKENED SLAB BELOW N.B.L. CONC. BLOCK WALLS
11900
COUNTINUOSLY POURED CONCRETE FOOTING COUNTINUOSLY POURED CONCRETE FOUNDATION WALL
PRELIMINARY NOT FOR CONSTRUCTION
2919
13058
960
DATE:
2019/12/13
DRAWN BY:
L,NGUYEN
CHECK BY:
NGUYEN & CASTILLO
PROJECT NO.:
14090
19-03
760
6000
5990
5
760
THICKENED SLAB BELOW N.B.L. CONC. BLOCK WALLS
B
FINAL
A
ISSUED FOR REVIEW
NO.
SUBMISSION
2019/12/13 2019/12/04
REVISION
DRAWING TITLE:
FDN. PLAN 32494
SHEET NO:
A203
DATE
1
2
3
10000
10000 41370
20000
1475
A
1200
NOTC TO A OPEN
3100
10000
10000
3100
NOTC TO A OPEN
1125
T N
B 766 4120
15925
6756
COUNTINUOSLY POURED CONCRETE FOUNDATION WALL
NOTCH AT FDN. WALL TO ACCEPT S.O.G. AT BARRIER FREE OPENING
41370
1100
12100
COUNTINUOSLY POURED CONCRETE FOOTING
NOTCH AT FDN. WALL TO ACCEPT S.O.G. AT BARRIER FREE OPENING
EXTERIOR CONCRETE PAD FOOTING CONCRETE PIER
INTERIOR CO CONCRETE PIE
TYP. STEEL COLUMN REFER TO STRUCT. DWGS.
TYP. STEEL CO REFER TO STRU
11900
31370
C
CONTINUOSLY POURED CONCRETE FOOTING
23514
COUNTINUOSLY POURED CONCRETE FOUNDATION WALL
CONTINUOSLY POURED CONCRETE FOOTING COUNTINUOSLY POURED CONCRETE FOUNDATION WALL 876
15350
1764
3443
2931
D
21635
6000
883
NOTCH AT FDN. WALL TO ACCEPT S.O.G. AT BARRIER FREE OPENING
3815
COUNTINUOSLY POURED CONCRETE FOUNDATION WALL
2310
E
Ex
4676
4200
41370
4
5
10000
10000
11370
10000
11370
3266
1100
5634
ZELLERS RETAIL COMPANY
CH AT FDN. WALL ACCEPT S.O.G. AT NING
LONDON CANADA
COUNTINUOSLY POURED CONCRETE FOUNDATION WALL
THICKENED SLAB BELOW N.B.L. CONC. BLOCK WALLS
CONTRACTOR NOTE:
COUNTINUOSLY POURED CONCRETE FOOTING
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
NOTCH AT FDN. WALL TO ACCEPT S.O.G. AT BARRIER FREE OPENING
681
CH AT FDN. WALL ACCEPT S.O.G. AT NING
NOTES:
3612
5920
960
THICKENED SLAB BELOW N.B.L. CONC. BLOCK WALLS
14300
3235
9888
ONCRETE PAD FOOTING ER
31370
20285
830
OLUMN UCT. DWGS.
inspire
NOTCH AT FDN. WALL TO ACCEPT S.O.G. AT BARRIER FREE OPENING
ARCHITECTURE
THICKENED SLAB BELOW N.B.L. CONC. BLOCK WALLS
11900
COUNTINUOSLY POURED CONCRETE FOOTING COUNTINUOSLY POURED CONCRETE FOUNDATION WALL
PRELIMINARY NOT FOR CONSTRUCTION
2919
13058
960
DATE:
2019/12/13
DRAWN BY:
L,NGUYEN
CHECK BY:
NGUYEN & CASTILLO
PROJECT NO.:
14090
19-03
760
6000
5990
5
760
THICKENED SLAB BELOW N.B.L. CONC. BLOCK WALLS
B
FINAL
A
ISSUED FOR REVIEW
NO.
SUBMISSION
2019/12/13 2019/12/04
REVISION
DRAWING TITLE:
FDN. PLAN 32494
SHEET NO:
A203
DATE
1
2
3
B A401
FL
T/O STEEL ROOF RECEIVING 257.898
COMPOSITE METAL PANEL
OVERHEAD LIGHT HEAD PAD
2210
3000
OVERHEAD DOOR SIDE PAD GUARD RAIL RETAINING WALL
EGRESS DOOR
DOCK BUMPER
CONCRETE STEP FOOTING REFER TO STRUCT. DWGS. TRUCK RAMP
NORTH ELEVATION SCALE 1:100
A A401 E
Ex
Dx
C
D
FLASHING
COMPOSITE METAL PANEL T/O STEEL ROOF RECEIVING 257.85
1664
T/O CANOPY
4132
700
ELE. 256.186
2210
TYP. CMP. COLUMN
EGRESS DOOR
CONCRETE FOUNDATION & FOOTING REFER TO STRUCT. DWGS.
OVERHEAD LIGHT
EAST ELEVATION SCALE 1:100
4
5
ZELLERS RETAIL COMPANY
5x
LASHING
LONDON CANADA
4000
T/O STEEL ROOF ELE. 260.498 THERALLY BROKEN PRE FIN. ALUM. CURTAIN WALL
CURTAIN WALL
312
2310 T/O STEEL SECOND FLOOR ELE. 256.498 T/O CANOPY
4288
ELE. 256.186
CONTRACTOR NOTE:
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
PRE FIN. ALUMINUM FLASHING TYP. SPLIT FACE ARCH. BLOCK T/O S.O.G. ELE. 251.898
NOTES:
LEGEND: SPLIT FACE ARCHITECTURAL BLOCK
TYP. ARCH. BLOCK
RED COMPOSITE METAL PANEL
CONC. FOUNDATION & FOOTING REFER TO STRUCT. DWGS.
DARK GRAY COMPOSITE METAL PANEL GRAY COMPOSITE METAL PANEL SPANDREL PANEL
B
A
inspire
T/O STEEL ROOF 260.498
ARCHITECTURE
4000
THERALLY BROKEN PRE FIN. ALUM. PUNCH WINDOW TYP.
PRELIMINARY
T/O STEEL SECOND FLOOR
NOT FOR CONSTRUCTION
4600
ELE. 256.498
DATE:
2019/12/13
DRAWN BY:
1070
100
L,NGUYEN
GUARD RAIL T/O S.O.G. FDN. RAMP & FOOTING & LANDING REFER TO STRUCT. DWGS.
ELE. 251.898
CHECK BY:
NGUYEN & CASTILLO
PROJECT NO.:
19-03
B
FINAL
A
ISSUED FOR REVIEW
NO. DRAWING TITLE:
SUBMISSION
REVISION
2019/12/13 2019/11/06 DATE
NORTH & EAST ELEVATIONS A301
SHEET NO:
5
4
3
1048
250
5x
T/O STEEL ROOF
1048
COMPOSI
700
ELE. 256.498 T/O CANOPY
1050
700
250
312
2310
1105
250
1048
ELE. 256.186 TYP. CMP. CANOPY TYP. CMP. COLUMN
1105
PRE FIN. ALUMINUM FLASHING TYP. SPLIT FACE ARCH. BLOCK TYP. ARCH. BLOCK
2210
T/O STEEL SECOND FLOOR
1048
4000
250
1048
260.498
EGRESS DOOR
CONCRETE FOUDATION &FOOTING - REFER TO SRUCTURAL DWGS
OVERHEAD LIGHT
SOUTH ELEVATION SCALE 1:100
Ax
8 A502
Bx
B
C
2000
A
OVERSIZED MULLION ALUMINUM CAP RED TYP. VISION PANEL
5275
THERALLY BROKEN PRE FIN. ALUM. CURTAIN WALL
1500
4072
CMP. CANOPY TYP. SPANDREL PANEL
700
ZELLER'S LOGO
TYP. CMP. COLUMN
2210
THERMALLY BROKEN ALUMINUM BARRIER-FREE STOREFONT ENTRANCE GRADE CONCRETE FOUNDATION & FOOTING REFER TO STRUCT. DWGS.
OVERHEAD LIGHT
WEST ELEVATION SCALE 1:100
2
2x
1
ZELLERS RETAIL COMPANY
FLASHING
250
LONDON CANADA
T/O STEEL ROOF RECEIVING
1048
ITE METAL PANEL
1048
250
1048
257.898
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
912
1048
250
1046
6000
CONTRACTOR NOTE:
T/O S.O.G. ELE. 251.898 NOTES:
LEGEND: SPLIT FACE ARCHITECTURAL BLOCK RED COMPOSITE METAL PANEL DARK GRAY COMPOSITE METAL PANEL GRAY COMPOSITE METAL PANEL SPANDREL PANEL
C A201
D
E
1000
FLASHING
1000
ELEV. 260.498
inspire
ARCHITECTURE
1000
4000
1000
COMPOSITE METAL PANEL
T/O STEEL ROOF
2050
312
700
T/O STEEL SECOND FLOOR
PRELIMINARY
ELE. 256.498 T/O STEEL CANOPY ELE. 256.186
NOT FOR CONSTRUCTION
4288
CURTAIN WALL
PRE FIN. ALUMINUM FLASHING TYP. SPLIT FACE ARCH. BLOCK TYP. ARCH. BLOCK T/O S.O.G. ELE. 251.898
DATE:
2019/12/13
DRAWN BY:
L,NGUYEN
CHECK BY:
NGUYEN & CASTILLO
PROJECT NO.:
19-03
B
FINAL
A
ISSUED FOR REVIEW
NO. DRAWING TITLE:
SUBMISSION
REVISION
2019/12/13 2019/11/06 DATE
SOUTH & WEST ELEVATIONS A302
SHEET NO:
SUB GIRT
C/L
TRANSITION MEMBRANE
578
PLY WOOD AND WOOD BLOCKING TRANSITION MEMBRANE TO OVERLAP 150 EACHWAY
150
TYP.ROOF CONST. BALLAST SINGLE PLY EPDM MEMBRANE TAPERED RIGID INSULATION 100 RIGID INSULATION0 VAPOUR RETARDER O.B.S SHEATHING OR EQUAL
T/O
PRE FIN. ALUMINUM FLASHING
PRE FIN. ALUMINUM FLASHING
BATTEN BAR T/O STEEL ROOF
C/L
475
TYP. ROOF CONST. BALLAST SINGLE PLY EPDM MEMBRANE TAPERED RIGID INSULATION 100 RIGID INSULATION0 VAPOUR RETARDER O.B.S SHEATHING OR EQUAL
TERMINATION BAR
TRANSITION MEMBRANE
BATTEN BAR
T/O STEEL ROOF ELE. 260.498
2 A501
A
1715
1050
323
T/O
TERMINATION BAR SUB GIRT 152 METAL STUD
2
1050
150
PLY WOOD AND WOOD BLOCKING TRANSITION MEMBRANE TO OVERLAP 150 EACH WAY
ELE. 260.498
TRANSITON MEMBRANE TO OVERLAP AT 150 EACH WAY
EW3A CURTAIN WALL
C/L
190 SPANDREL PANEL
1 A501
38 METAIL DECK-REFER TO STRUCTURAL DRAWING
METAIL DECK-REFER TO STRUCTURAL DRAWING
C/L
1075
OWSJ. REFER TO STRUCT. DWGS.
OWSJ. REFER TO STRUCT. DWGS.
C/L
150
GYPSUM BOARD CEILING EW3A CURTAIN WALL
4000
C/L
2548
1316
WAREHOUSE 113
190 VISION PANEL
HUMAN RESOURCE 207
C/L
C/L
347
1048
EW2A COMPOSITE METAL PANEL (51) COMPOSITE METAL PANEL 50 AIR SPACE 50 POLYERUTHANE INSULATION R15 190 CONCRETE BLOCK
C/L
252
C/L T/O STEEL 2ND FLOOR
C/L
EW3C CURTAIN WALL P1C FURRING CHANNEL 190 CURTAIN WALL 25 AIR SPACE 190 CONCRETE BLOCK 23 METAL FURRING CHANNEL 13 GYPSUM BOARD
BENT ALUMINUM ANGLE TYP. FLOOR CONST. 75 C.I.P. CONCRETE METAL DECKREFER TO STRUCT. DWGS.
1048
1278
8600
ELE. 256.498
C/L
C/L
3022
1048
GYPSUM BOARD CEILING
RETAIL 105
278
4600
C/L
1377
C/L
C/L
C/L
EW3C CURTAIN WALL 190 CURTAIN WALL 25 AIRSPACE 190 CONCRETE BLOCK
FLASHING SUB GIRT
ELE. 251.898
150
B/O
T/O S.O.G.
ELE. 251.898
PROVIDE POSITIVE SLOPE
GRADE
B/O
FLASHING c/w WINDOW SHIM PROVIDE POSITIVE SLOPE
GRADE TYP. FOUNDATION & FOOTING CONSTR. POURED CONCRETE FDN. WALL REFER TO STRUCTURE DRAWINGS POURED CONCRETE FOORING REFER TO STRUCTURE DRAWINGS
BACK FILL 50 RIGID INSULATION 610 EACH WAY
SECTION @ COMPOSITE METAL PANEL SCALE 1:20
1220
1220
TYP. FOUNDATION & FOOTING CONSTR. POURED CONCRETE FDN. WALL REFER TO STRUCTURE DRAWINGS POURED CONCRETE FOORING REFER TO STRUCTURE DRAWINGS
A A401
TYP. FLOOR CONSTR. 150 CAST IN PLACE CONC. C/W WELDED WIRE MESH REFER TO STRUCUTRAL DRAWING 6 MIL VAPOUR BARRIER 150 COMPACTED GRANULAR FILL
1025 T/O S.O.G.
150
1133
TYP. WAREHOUSE FLOOR CONSTR. 200 CAST IN PLACE CONC. C/W WELDED WIRE MESH REFER TO STRUCUTRAL DRAWING 6 MIL VAPOUR BARRIER 150 COMPACTED GRANULAR FILL
B A401
SECTION @ CURTAIN WALL SCALE 1:20
BACK FILL 50 RIGID INSULATION-610 EACH WAY
4
PRE FIN. ALUMINUM FLASHING
150 T/O
TERMINATION BAR
1000
TYP. ROOF CONST. BALLAST SINGLE PLY EPDM MEMBRANE TAPERED RIGID INSULATION 100 RIGID INSULATION0 VAPOUR RETARDER O.B.S SHEATHING OR EQUAL 152 METAL STUD
5
PLY WOOD AND WOOD BLOCKING TRANSITION MEMBRANE TO OVERLAP 150 EACHWAY
ZELLERS RETAIL COMPANY
T/O STEEL ROOF ELE. 260.498
METAIL DECK-REFER TO STRUCTURAL DRAWING OWSJ.-REFER TO STRUCTURAL DRAWING
1000
C/L
LONDON CANADA
EW2B COMPOSITE METAL PANEL 51 METAL PANEL 150 AIR SPACE 50 POLYURETHANE SPRAY FOAM INSULATION R15 190 CONCRETE BLOCK
1000
C/L
CONTRACTOR NOTE:
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
4000
WAREHOUSE 113
1000
C/L
TYP. ROOF CONST. BALLAST SINGLE PLY EPDM MEMBRANE TAPERED RIGID INSULATION 100 RIGID INSULATION0 VAPOUR RETARDER O.B.S SHEATHING OR EQUAL
484
150
C/L
NOTES:
T/O
362
B/O
T/O STEEL 2ND FLOOR
1359
ELE. 256.498
7 A502
METAIL DECKING-REFER TO STRUCTURAL DRAWING
EW3A CURTAIN WALL 190 CURTAIN WALL
inspire
4600
P2B CONCRETE BLOCK 140 CONCRETE BLOCK
CAFE 111
1812
C/L
ARCHITECTURE
C/L
1235
PRELIMINARY NOT FOR CONSTRUCTION C/L
DATE:
TYP. WAREHOUSE FLOOR CONSTR. 200 CAST IN PLACE CONC. C/W WELDED WIRE MESH REFER TO STRUCUTRAL DRAWING 6 MIL VAPOUR BARRIER 150 COMPACTED GRANULAR FILL
TYP. FLOOR CONSTR. 150 CAST IN PLACE CONC. C/W WELDED WIRE MESH REFER TO STRUCUTRAL DRAWING 6 MIL VAPOUR BARRIER 150 COMPACTED GRANULAR FILL
1010 5 COURSES OF BLOCKS
2019/12/13
EW1 ARCHITECTURE BLOCK 90 ARCHITECTURE BLOCK 60 AIR SPACE 50 POLYURETHANE SPRAY FOAM INSULATION R15 190 CONCRETE BLOCK
DRIP EDGE
B/O
150
PROVIDE POSITIVE SLOPE
DRAWN BY:
LN, NGUYEN
CHECK BY:
CASTILLO
PROJECT NO.:
19-03
T/O S.O.G. ELE. 251.898
GRADE
C A401
SECTION @ CURTAIN WALL/ ARCH. BLOCK SCALE 1:20
1220
50 RIGID INSULATION-610 EACH WAY
TYP. FOUNDATION & FOOTING CONSTR. POURED CONCRETE FDN. WALL REFER TO STRUCTURE DRAWINGS POURED CONCRETE FOORING REFER TO STRUCTURE DRAWINGS
B
FINAL SUBMISSION
2019/12/13
A
ISSUED FOR REVIEW
2019/10/30
NO.
REVISION
DRAWING TITLE:
DATE
WALL SECTIONS
SHEET NO:
A401
5961 409
4506
OFFICE AREA
TACTILE INDICATIOR SLIP RESISTANCE TREAD AT NOSING
209
TACTILE INDICATIOR
190
30 DIA. STEEL GUARD RAIL. PAINTED
300
1130 LANDING WITDH
528
9 IN 77 G RE DU CT IO
N
DN 24 RISERS @ 196.375
SW
STAIRWELL 106
OR
254
1685 LANDING DEPTH
DO 83 129
200
1238 LANDING DEPTH
355
1100 M.O.
OPEN TO BELOW
2750
1HR F.R.R.
30 DIA. STEEL GUARD RAIL. PAINTED
DN 24 RISERS @ 196.375
71
340
1345
A A402
1130 LANDING WITDH
300
STEEL STAIR PAN C.W CONC. INFILL
5700 300
190
100
30 DIA. STEEL GUARD RAIL. PAINTED
340
A
30 DIA. STEEL HANDRAIL. PAINTED 1HR F.R.R.
2
1 A402
ENGLARGED STAIR PLAN AT SECOND FLOOR SCALE 1:25 N
5961 1HR F.R.R.
1100 M.O.
355
190
4506
71
5700
190
CT
ION
359
2750
OR
217
DO
STAIRWELL 106
SW 108 ING 0 RE DU
30 DIA. STEEL HANDRAIL. PAINTED
30 DIA. STEEL GUARD RAIL. PAINTED SLIP RESISTANCE TREAD AT NOSING
1100
UP 24 RISERS @ 196.375
A A402
257 528
TACTILE INDICATOR 1605 LANDING STEEL STAIR PAN C.W CONC. INFILL
100
30 DIA. STEEL GUARD RAIL. PAITED
340
A
4506
1100 M.O.
2 2 A402
ENGLARGED STAIR PLAN AT GROUND FLOOR SCALE 1:25
N
1HR F.R.R.
ZELLERS RETAIL COMPANY
B T/O STEEL ROOF ELE. 260.498
LONDON CANADA
CONTRACTOR NOTE:
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
C/L
C/L
C/L
NOTES:
C/L
915
915
1070
2210
916
TYP. LANDING CONSTRUCTION 75 C.I.P. CONCRETE 38 METAL DECK REFER TO STRUCT. DWGS.
T/O STEEL 2ND FLOOR ELE. 256.498
2511.0 11 TREADS AT 257.25
1070
2356.5 12 RISERS AT 196.375
1868
TYP. LANDING CONSTRUCTION
C/L
942
75 C.I.P CONCRETE 38 METAL DECK REFER TO STRUCT. DWGS.
C/L
942
2 A403
C/L
inspire
30 DIA. STEEL GUARD RAIL. PAINTED 10 DIA. STEEL PICKET @ 100MM O.C. PAINTED STEEL 'C' CHANNEL REFER TO STRUCT. DWGS.
ARCHITECTURE
30 DIA. STEEL POST. PAINTED
965
943 C/L
C/L
1366 T/O S.O.G. ELE. 251.898
981
140
2019/12/13
DRAWN BY:
L,NGUYEN
2511 11 TREADS AT 257.25
CHECK BY:
NGUYEN & CASTILLO
1 A403
A A402
STAIR SECTION SCALE 1:25
NOT FOR CONSTRUCTION DATE:
30 DIA. STEEL GUARD RAIL. PAINTED STEEL STAIR PAN C.W CONC. INFILL.
PRELIMINARY
2326.5 12 RISERS AT 196.375 2210
STEEL 'C' CHANNEL STRINGER PAINTED REFER TO STRUCT. DWGS.
PROJECT NO.:
19-03
B
FINAL
A
ISSUED FOR REVIEW
NO.
SUBMISSION
REVISION
2019/12/13 2019/11/27 DATE
ENLARGED STAIR PLANS & SECTION A402 DRAWING TITLE:
SHEET NO:
50 DIA. STEEL POST. PAINTED 38 DIA. STEEL GUARDRAIL SYSTEM. PAINTED 10 DIA. STEEL PICKET AT 100MM O.C. PAINTED
25
25
STEEL STAIR PAN C.W CONC. INFILL REFER TO ROOM FINISH SCHEDULE FINISHED FLOOR REFER TO ROOM FINISH SCHEDULE
STEEL 'C' CHANNEL STRINGER PAINTED REFER TO STRUCT. DWGS.
1 A403
STAIR SECTION @ B/O FLIGHT SCALE 1:10
BASE BOARD
35
STEEL ANGLE ATTACH TO STEEL STRINGER AND CONCRETE SLAB
ZELLERS RETAIL COMPANY LONDON CANADA
50 DIA. STEEL POST. PAINTED 38 DIA. STEEL GUARDRAIL SYSTEM. PAINTED 10 DIA. STEEL PICKET AT 100MM O.C. PAINTED
CONTRACTOR NOTE:
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
25
NOTES:
25
LEGEND:
ABBREVIATIONS: STEEL STAIR PAN C.W CONC. INFILL REFER TO ROOM FINISH SCHEDULE FINISHED FLOOR REFER TO ROOM FINISH SCHEDULE
STEEL 'C' CHANNEL STRINGER PAINTED REFER TO STRUCT. DWGS.
1 A403
BASE BOARD
35
STEEL ANGLE ATTACH TO STEEL STRINGER AND CONCRETE SLAB
STAIR SECTION @ B/O FLIGHT
inspire
SCALE 1:10
ARCHITECTURE
PRELIMINARY NOT FOR CONSTRUCTION DATE:
2019/12/13
DRAWN BY:
L,NGUYEN
CHECK BY:
NGUYEN & CASTILLO
PROJECT NO.:
19-03
B
FINAL
A
ISSUED FOR REVIEW
NO.
SUBMISSION
REVISION
DRAWING TITLE:
STAIR DETAILS SHEET NO:
A403
2019/12/13 2019/11/27 DATE
A
2
SUB GIRT REFER TO STRUCT. DWGS.
T/O
C/L
TRANSITION MEMBRANE TO OVERLAP 150 EACH WAY
19 SHEATHING ON BOTH SIDES OF STUD
BATTEN BAR
METAL STUD C/W POLYURETHANE SPRAY FOAM INSULATION REFER TO STRUCT. DWGS.
SINGLE PLY EPDM MEMBRANE
19 SHEATHING ON BOTH SIDE OF STUD
TAPERED INSULATION 100 INSULATION
152 METAL STUD REFER TO STRUCT. DWGS.
578
BALLAST
STEEL BEAM REFER TO STRUCT. DWGS.
16 O.B.S. BOARD
190 SPANDREL PANEL T/O STEEL ROOF ELE. 260.498
470
BLOCK INFILL
38 METAL DECK REFER TO STRUCT. DWGS.
STEEL BEAM REFER TO STRUCT. DWGS. TRIMMER ANGLE REFER TO STRUCT. DWGS.
1705
C/L
TRANSITION MEMBRANE TO OVERLAP 150 EACH WAY
T/O
STEEL ANGLE REFER TO STRUCT. DWGS.
STEEL ANGLE REFER TO STRUCT. DWGS. T/O STEEL ROOF ELE. 260.498
150
PLYWOOD WOOD BLOCKING
FLASHING
315
SUB GIRT REFER TO STRUCT. DWGS.
150
PLYWOOD WOOD BLOCKING
TRANSITION MEMBRANE TO OVERLAP 150 EACH WAY VAPOUR RETARDER TERMINATION BAR
OWSJ. REFER TO STRUCT. DWGS. BRIDGING REFER TO STRUCT. DWGS.
OWSJ. REFER TO STRUCT. DWGS.
C/L
GYPSUM 190 CONC. BLOCK C/L 190 VISION PANEL
1 A501
PARAPET @ COMPOSITE METAL PANEL
2 A501
SCALE 1:10
PARAPET @ CURTAIN WALL SCALE 1:10
D 328 65
263
E
38 METAL PANEL 50 AIR SPACE 50 POLYURETHANE SPRAY FOAM INSULATION R15
RECEIVING AREA 119
CAFE 111
190 CONCRETE BLOCK
65
90 BLOCK COLUMN COVER PANEL EXTRUSION FDN. WALL BELOW PANEL FILLER
325
250X250 COLUMN REFER TO STRUCT. DWGS.
265
125 STEEL COLUMN REFER TO STRUCT. DWGS
WAREHOUSE 113
415 540
265
65
90 BLOCK COLUMN COVER C/W BULLNOSE
325
2
325
268
140 CONC. BLOCK
390
65
263 328
328
190 CONC. BLOCK 50 POLYURETHANE SPRAY FOAM INSULATION R15
FOUNDATION WALL BELOW BLOCK INFILL TRANSITION MEMBRANE TO OVERLAP 150 EACH WAY
MECHANICHAL ELECTRICAL 114
60 AIR SPACE 90 ARCHITECTURAL BLOCK
4 A501
INTERIOR CORNER @ C.M. PANEL SCALE 1:10
5 A501
EXTERIOR CORNER @ ARCH. B SCALE 1:10
E
SINGLE PLY EPDM MEMBRANE TRANSITION MEMBRANE TO OVERLAP 150 EACH WAY VAPOUR RETARDER TERMINATION BAR
628
FLASHING 265
363
WAREHOUSE 113 320
TRANSITION MEMBRANE TO OVER LAP 150 EACH WAY
90 BLOCK COLUMN COVER C/W BULLNOSE
25X11BATTEN BAR BALLAST TAPERED RIGID INSULATION 100 RIGID INSULATION 16 O.S.B. BOARD
ZELLERS RETAIL COMPANY
150 AIR SPACE
50 POLYURETHANE SPRAY FOAM INSULATION R15
70
4
CAFE 111
PANEL FILLER PANEL EXTRUSION WOOD BLOCKING
140 CONCRETE BLOCK
38 METAL DECK REFER TO STRUCT. DWGS.
LONDON CANADA
TRANSITION MEMBRANE OVERLAP 150 EACH WAY 38 METAL PANEL CLIP ANGLE
STEEL COLUMN -REFER TO STRUCT. DWGS
65
CONTRACTOR NOTE:
VISION PANEL
150
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
FDN. WALL BELOW
190 BLOCK C/W BULLNOSE
340 65
405
NOTES:
M BOARD CEILING
CURAINTWALL @ C.M. PANEL
3 A501
SCALE 1:10
E
390
CAFE 111
325
405
inspire
340
65
ARCHITECTURE
90 BLOCK COLUMN COVER C/W BULLNOSE STEEL COLUMN REFER TO STRUCT. DWGS.
PRELIMINARY
190 CONC. BLOCK C/W BULLNOSE
65
265
NOT FOR CONSTRUCTION 605
340
405
5 DATE:
2019/12/13
340
325
5
DRAWN BY:
LN, NGUYEN
CHECK BY:
NGUYEN&CASTILLO
VISION PANEL FOUNDATION WALL BELOW BLOCK INFILL
325
BLOCK
TRANSITION MEMBRANE TO OVERLAP 150 EACH WAY
PROJECT NO.:
19-03
265
340 605
SPANDREL PANEL C/W BACK ROD AND CAULKING
B
FINAL SUBMISSION
2019/12/13
A
ISSUED FOR REVIEW
2019/10/30
NO. DRAWING TITLE:
6 A501
EXTERIOR CORNER @ CURTAIN WALL SCALE 1:10
REVISION
PLAN & SECTION DETAILS A501
SHEET NO:
DATE
4
B
150
38 METAL PANEL 150 AIR SPACE 50 POLYURETHANE SPRAY FOAM INSULATION
BALLAST SINGLE PLY EPDM MEMBRANE
190 CONCRETE BLOCK
100 RIGID INSULATION
T/O
558
TAPERED RIGID INSULATION VAPOUR RETARDER
SUB GIRT REFER TO STRUCT. DWGS. 132 RIGID INSULATION 19 SHEATHING BOARD BATTEN BAR
16 OSB BOARD COUNTER FLASHING
38 METAL DECK REFER TO STRUCT. DWGS. OWSJ. REFER TO STRUCT. DWGS. B/O
TRANSITION MEMBRANE TO OVERLAP 150 EACH WAY
STEEL ANGLE
401
T.O.S FIRST FLOOR METAL DECK REFER TO STRUCT. DWGS.
ELE. 256.498
OWSJ. REFER TO STRCUT. DWGS. STEEL BEAM REFER TO STRUCT. DWGS. STEEL BEAM REFER TO STRUCT. DWGS.
T/O STEEL CANOPY ELEV. 256.186 C CHANNEL REFER TO STRUCT. DWGS.
140 CONCRETE BLOCK
SI T 10 16
GUTTER BEAM REFER TO STRUCT. DWGS. BACK ROD AND CAULKING
38 R C V
7 A502
LOW ROOF @ WAREHOUSE SCALE 1:10
INTENTIONALLY LEFT BLANK
8 A502
CANOPY @ MAIN ENTRY SCALE 1:10
INTENTIONALLY LEFT BLANK
ZELLERS RETAIL COMPANY
152 METAL STUD c/w POLYURETHANE SPRAY FOAM INSULATION 19 SHEATHING BOARD 60 AIR SPACE SPANDREL PANEL
LONDON CANADA
COUNTER FLASHING TRANSITION MEMBRANE TO OVER LAP 150 EACH WAY
INTENTIONALLY LEFT BLANK
VAPOUR RETARDER BATTEN BAR BALLAST CONTRACTOR NOTE:
CONTRACTOR SHALL CHECK ALL DIMENSIONS ON THE DRAWINGS AND REPORT ANY DISCREPANCIES TO THE CONSULTANT BEFORE PROCEEDING. ALL DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE CONSULTANT AND MUST BE RETURNED AT THE COMPLETION OF THE WORK. DRAWINGS ARE NOT TO BE SCALED.
INGLE PLY EPDM MEMBRANE TAPERED RIGID INSULATION 00 RIGID INSULATION 6 OSB PROTETION BOARD
NOTES:
8 METAL DECK REFER TO STRCUT. DWGS. CLADDING VISION PANEL
inspire
ARCHITECTURE
PRELIMINARY NOT FOR CONSTRUCTION DATE:
INTENTIONALLY LEFT BLANK
2019/12/13
DRAWN BY:
LN, NGUYEN
CHECK BY:
NGUYEN, CASTILLO
PROJECT NO.:
19-03
A
FINAL SUBMISSION
2019/12/13
A
REVISION_1
2019/10/30
NO. DRAWING TITLE:
REVISION
PLAN & SECTION DETAILS A502
SHEET NO:
DATE
04
Oxford Health
4
Family Centre
Understanding that going to medical centres may make the clients feel daunted, my design goal is to allow the patients to be comfortable as if they are in their own homes. Blue evokes tranquility, therefore, I chose Decorator’s White as the major paint color and Black Pepper as accent color. The light blue walls and ceiling make the room brighter and larger. The wood color provides warmth; and since woodlike flooring is used in most of Canada’s households, it enhances the home-like feel to the client, making them feel more secured. Round shapes have a softening effect. We can see curves at the archway to the children’s playroom, or at the reception desk.
decorator’s white oc-149
black pepper 2130-40
sheet veneer
Thank You Long Nguyen nglong1302@gmail.com