General Arrangement Plan (Ground Floor)
General Arrangement Plan (First Floor)
Visual created by visualiser employed by MARIS Interiors
Visual created by visualiser employed by MARIS Interiors
Visual created by visualiser employed by MARIS Interiors
Visual created by visualiser employed by MARIS Interiors
General Arrangement Plan
High Level Co-ordinated
DOOR AND A HALF
SINGLE DOOR
DOUBLE DOOR
UNIQUE DOOR TYPE (CHECK DRAWING)
DOOR FINISH (G - GLASS, T - TIMBER P-PAINTED.)
TIMBER FRAME (P - PAINTED, T - TIMBER)
FRAME THICKNESS (AS PARTITIONS)
ALUMINIUM FRAME - POLISHED
ALUMINIUM FRAME FINISH
LEVER HANDLES (ON ROSE)
MANIFESTATION
FIRE SIGNAGE
FULL HEIGHT GLAZED
VISION PANEL (SEE DRAWING)
VISION PANEL (CIRCULAR)
VISION PANEL (SPECIAL)
DISABLED BATHROOM LOCK
LOCK (THUMB TURN)
ESCUTCHEON PLATE
PUSH PLATES
PULL HANDLE / S
KICKPLATE
DOOR CLOSER
SECURITY DOOR
DOOR STOP
ACCESS CONTROL DEVICE - BY CLIENT
RECESSED FLOOR SPRINGS
SIGNAGE - By Client
-
-
P
-
-
P
-
-
T
-
-
-
P
-
-
-
-
P
-
-
-
-
-
-
P
-
-
P
-
-
P
-
-
-
-
-
-
-
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P
-
-
-
-
P
-
-
-
-
-
-
P
-
-
P
-
-
P
-
-
-
-
-
P
-
-
DOOR N2.03
R2.05 - CLEANERS STORAGE
T1
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P
-
-
-
-
-
-
-
-
P
-
-
P
-
-
P
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.04
R2.09 - OFFICE (IT)
T4
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P P
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.05
R2.10 - OFFICE (CAT)
T4
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P P
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.06
R2.11 - OFFICE (NOT ASSIGNED)
T4
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P P
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.07
R2.13 - MEETING ROOM 1
T3
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P
-
-
-
-
-
-
-
-
-
-
-
P
-
-
P
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.08
R2.14 - MEETING ROOM 2
T3
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P
-
-
-
-
-
-
-
-
-
-
-
P
-
-
P
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.09
R2.17 - MEETING ROOM 3
T3
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P
-
-
-
-
-
-
-
-
-
-
-
P
-
-
P
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.10
R2.18 - MEETING ROOM 4
T3
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P
-
-
-
-
-
-
-
-
-
-
-
P
-
-
P
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.11
R2.19 - MEETING ROOM 5
T3
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P
-
-
-
-
-
-
-
-
-
-
-
P
-
-
P
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.12
R2.21 - OFFICE (NOT ASSIGNED)
T4
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P
-
-
-
-
-
-
-
-
-
-
-
P
-
-
P
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.13
R2.22 - OFFICE (NOT ASSIGNED)
T4
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P P
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.14
R2.23 - OFFICE (FINANCE - PAYROLL)
T4
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P P
-
-
-
-
-
-
-
P
-
-
-
-
-
-
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.15
R2.24 - OFFICE (FINANCE - HOTDESK)
T4
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P P
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.16
R2.25 - OFFICE (FINANCE)
T4
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P P
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
P
-
-
-
-
-
-
-
-
DOOR N2.17
R2.30 - RECEPTION AREA / WAITING
T5
P
-
-
-
-
P
-
-
-
-
P
G
-
-
-
P
-
-
-
-
-
-
-
-
-
-
-
P
-
-
P
-
-
P
-
-
-
-
-
P
-
-
DOOR N2.18
R2.03 - MICROWAVE ROOM
T1
P
-
-
-
-
P
-
-
P
-
-
T
-
-
-
P
-
-
-
-
P
-
-
-
-
-
-
P
-
-
P
-
-
P
-
-
-
-
-
-
-
-
EMERGENCY THUMB TURN
STANDARD HEIGHT
-
-
HOLD OPEN DEVICE
FULL HEIGHT TO CEILING (PART -P)
-
P
FLUSH BOLTS 1 LEAF ONLY
FIRE RATED WITH SMOKE SEAL
P
T2
TYPE
DEAD LOCK WITH SIGN INDICATOR
FIRE RATED 90 MINUTES
T1
R2.04 - COMMS ROOM
LOCATION
DIGITAL LOCK
FIRE RATED 1 HOUR
R2.03 - MICROWAVE ROOM
DOOR N2.02
DOOR No.
ENGAGED INDICATOR BOLT
FIRE RATED 30 MINUTES
DOOR N2.01
SECOND FLOOR
FIXED HANDLES (1-BOTH SIDES)
NEW DOOR
SATIN FINISHED STAINLESS STEEL
ADDITIONAL NOTES
NEW DOOR Second Floor
* REFER TO DRAWING '22608_01_02_D09'
C B A REV
838
838
838
838
910
910
910
910
DRAW
CO
QUAL
MARIS
CLIEN
Property & Use of dra consent of
Chr
Address
Cardin 80 Vic Londo
Project N
226
Drawing
Doo
Produce
TYPE '1'
Door Schedule
FULL HEIGHT INTERNAL SOLID SINGLE DOOR ALUMINIUM FRAME + VISION PANEL
TYPE '2'
FULL HEIGHT INTERNAL SOLID SINGLE DOOR ALUMINIUM FRAME + ACCESS PANEL / VISION PANEL
TYPE '3'
FULL HEIGHT INTERNAL SOLID SINGLE DOOR ALUMINIUM FRAME 'D' HANDLE
TYPE '4'
FULL HEIGHT INTERNAL SOLID SINGLE DOOR ALUMINIUM FRAME 'LEVER' HANDLE
AD/NA
TYPE '5'
FULL HEIGHT INTERNAL GLAZED SINGLE DOOR SPRING LOADED DOOR ALUMINIUM FRAME
MAR
The Har 65 Sout London
Flo
E
Minor amend
D
Construction
C
For contract
B
Minor amend
A Alum. transom 180x60x4
Minor amend
-
Drawing first
REV
DESCRIPTIO
DRAWING STA
CONSTR
QUALITY CONT MARIS
SIGNED:
MAG-LOCK
ARMATURE PLATE
DATE:
CLIENT SIGNED:
PRINT NAME:
DATE:
Property & Copyright © MA Use of drawings is not permit consent of the LLP.
Christie' Address
Cardinal Place 80 Victoria Stree London, SW1 Project Number
22608
Drawing Title
Reception Produced by
AD/NA
MARIS INT
The Harlequin Buildin 65 Southwark Street London SE1 0HR
Door Detail
Coffee Point Detail
E
Stor
D
Con
C
For
B
Mino
A
Mino
-
Draw
REV
DES
DRAWING
CON
QUALITY MARIS
SI
DA
CLIENT SI
PR
DA
Property & Copy Use of drawings is consent of the LLP
Chris Address
Cardinal P 80 Victoria London, S
Project Numb
2260
Drawing Title
Breako Produced by
AD/NA
MARIS
The Harlequi 65 Southwark London SE1
Coffee Point Detail
-
Dra
REV
DE
DRAWIN
PRE
QUALITY MARIS
S
D
CLIENT S
P
D
Property & Cop Use of drawings consent of the L
All designs are the disclosed to a thir this drawing are s electronic copy. D and any scaling o components on-si commencement o Any claims for var such variation or e
This drawing mus provided. Check s millimetres unless
QMU Address
St Bartho Barts and West Sm
Project Num
2288
Drawing Titl
1st Flo [Optio
Produced by
LA/NA
MARIS
The Harlequ 65 Southwa London SE1
GA Version 1
-
Dra
REV
DE
DRAWIN
PRE
QUALITY MARIS
S
D
CLIENT S
P
D
Property & Cop Use of drawings consent of the L
All designs are the disclosed to a thir this drawing are s electronic copy. D and any scaling o components on-si commencement o Any claims for var such variation or e
This drawing mus provided. Check s millimetres unless
QMU Address
St Bartho Barts and West Sm
Project Num
2288
Drawing Titl
1st Flo [Optio
Produced by
LA/NA
MARIS
The Harlequ 65 Southwa London SE1
GA Version 2
3 Versions of siingle space
LEGEND - BUILDERS WORK Existing wall retained External cavity wall (Refer to wall types drawing) 100mm internal stud partition (See notes below) New 102.5mm thick brickwork 300mm thick party wall 140mm Blockwork wall (See notes below)
Beechworth House Single Storey - Approx. Extent
B
C
AB
Floor recess
NEW EDGE OF PILE CAP (REVISED 11.04.16)
6
1
400W X 460D RC Beam (above)
5 4
14
3
16
Boiler 400 x 330mm
W/M
Shared Bathroom
ROOF WALLS FLOORS PARTY WALLS WINDOWS -
C1 400W X 460D RC Beam (above)
1
11
10
9
12
13
14
15
16
7
4
10
3
11
2
5
1
cupboard (Indicative)
12
7
RWP 3 T/B
Roof below
13 RWP 3 F/A T/B
W13
14
Lobby
DIMENSIONS TO BE VERIFIED ON-SITE - ANY DISCREPANCIES TO BE REPORTED TO DESIGN TEAM
400W X 460D RC Beam (above)
Shared Bathroom
8
0.13 W/m²K 0.15 W/m²K 0.12 W/m²K 0.18 W/m²K 1.4 W/m²K
RWP 1 F/A
Gutter line
Bedroom 2
4
D02
D01
D02
NPA
13 10 16
06 COLUMN POSITION AS BUILT
NPA
28 07 16
NPA
28 07 16
05 CEILING BULKHEAD SHOWN
NPA
21 07 16
04 FRONT LIGHTWELL MOVED
NPA
18 04 16
03 DUPLEX 4 STAIR MOVED
NPA
14 04 16
02 UPDATED PILE CAP INFORMATION
NPA
12 04 16
01 FOR CONSTRUCTION
NPA
29 03 16
Rev
D02
ACO drain
Open Lightwell (Above)
Open Lightwell (Above)
Description
By
C
D
DUPLEX 3
En Suite
W13
W13
RWP 5 F/A
4
cupboard (Indicative)
cupboard (Indicative)
Lobby
6
7
3
10
2
11
1
12 13
7
8
9
14
Bedroom 3
Lobby NEW BOXING TO SUIT BOILER FLUE / SVP POSITION (25.10.16)
En Suite
09
4
3
D03
D03
D03
08 07
D03
06
Terrace (Laid to falls)
Terrace (Laid to falls)
Terrace (Laid to falls)
Terrace (Laid to falls)
2
2 RWP 6 F/A T/B
Roof below
Date
RWP 7 F/A T/B
Roof below
RWP 8 F/A T/B
Roof below
05 04 03 02
RWP 9 F/A T/B
Roof below
01 Rev
GENE
This drawing is to be read in conjunction with all relevant consultants and/or specialists drawings/documents and any discrepancies or variations are to be notified to the architects in writing before the affected work commences. All queries relating to design of structural elements are to be referred to the structural engineering consultant for resolution.
DUPLEX 2
RWP 4 F/A
This scheme is subject to Town Planning and all other necessary consents.
1
B
5
2
This sc consen
Dimensions, areas and levels where given are only approximate and subject to site survey. All dimensions are to be checked on site. All feasibility studies are subject to full site survey.
1
DUPLEX 1
RWP 5 F/A
3
1
GENERAL NOTES
400W x 600D RC Beam (above)
A
14
CONSTRUCTION
DOOR SIZE CHANGED (REFER TO DRAWING 15-02_707)
Pump controls cabinet
Open Lightwell (Above)
Pump controls cabinet
ACO drain
Pump controls cabinet
Pump controls cabinet
ACO drain
Pump controls cabinet
2
C1
D02
ACO drain
Open Lightwell (Above)
600W x 600D RC Beam (above)
500W x 600D RC Beam (above)
Pump controls cabinet
D01
13
4
4
07 BATHROOM LAYOUTS REVISED
PILE WALL EDGE AS BUILT
D02
12
RWP 4 T/B
6
5
Bedroom 2
1
3
D01
12 13
Lobby
230
2
AA
C1
11
7
Bedroom 2 Desk (Indicative)
3
C1
2
10
2
Shared Bathroom
5 4
C1
4 3
1
8
9
10 11
Private stair 4
6
500W x 600D RC Beam (above)
9
cupboard (Indicative)
AA
600W x 600D RC Beam (above)
8
5
14
C1
4
6
Velux (Above)
7
W/M
C1 C1
2
15
16
Shared Bathroom
6
12 13
W13
9
NO 1 ALFRED ROAD
15
RWP 3 T/B
8
5
Velux (Above)
C1
13 14
RWP 2 F/A T/B
Private stair 10
4 3 2
Private stair 3
11
12
5
Lightwell above (Frosted)
Boiler 400 x 330mm
1
Boiler 400 x 330mm
2
16
6
Roof below
BUILDING ELEMENTS TO ACHEIVE U VALUES AS FOLLOWS:
7
W/M
15 W / M
9
10
11
7
Private stair 8
10
230
3
14
9
Private stair 2
6
230
5
7
Shared Bathroom
4
RWP 1 T/B
THERMAL PERFORMANCE
230
6
8
5
12 13
E
D
Shared Bathroom
Private stair 1 11
RWP 1 T/B
Gutter line
DRAINAGE SHOWN INDICATIVE - SPECIALIST TO DESIGN AND SPECIFY DRAINAGE SYSTEM INCLUDING PUMPED DRAINAGE TO BASEMENT AND SURFACE WATER DRAINAGE
7
Velux (Above)
8
Private stair 7
Below ground sewer
9
C
Drainage pipework
FOR DETAILS OF WALL TYPES REFER TO WALL TYPES DRAWING ISSUED SEPARATELY
10
B
Foul/surface water drainage Refer to drainage engineer's specialist scheme
EDGE OF PROPOSED TANKING INTERIOR WALL LINE
6
Beechworth House Single Storey - Approx. Extent
Beechworth House - Approx. Extent
Slab opening
E
D
Private stair 6
AB
Mass concrete basement wall Refer to structural engineer's detail design
Velux (Above)
Beechworth House - Approx. Extent
1
This dr and/or variatio affecte
1
All que to the s
The workmanship and materials of all trades and building operations shall comply with the recommendations of British Standard (BS)8000 parts 1-16 inclusive and with Approved Document to support Regulation 7 1999 edition (incorporating 2000 amendments) of the Building Regulations 2010.
E
DUPLEX 4
Dimens subject feasibi
A
All design and construction is to be in accordance with the Construction (Design and Management) Regulations 2007.
C
DUPLEX 9
D
DUPLEX 10
E
TRIPLEX 7
All des Constru
ZERO ALFRED ROAD LONDON W3 6LH
Site
Basement Floor
B
DUPLEX 8
The wo shall co parts 1Regula Building
Site
Third Floor
GENERAL ARRANGEMENT 10 UNIT BASEMENT LEVEL
Title
Scale @ A1
1:50
Scale @ 1:50
Homes to make you happy Unit 3, 51 Derbyshire Street, London. E2 6JQ | +44 (0)20 7729 4189
2.5m
2m
1.5m
1m
0.5m
0m
Date
Drawn
09 2016
NPA
Title
Checked
Scale @
-
Job No
Drawing No
Revision
15-02
C101
07
1:50
Scale @ 1:50
Homes to make you happy © 2016 UPLIFT PROPERTY LTD. All rights reserved. Unit 3, 51 Derbyshire Street, London. E2 6JQ | +44 (0)20 7729 4189
2.5m
2m
Job No
1.5m
1m
0.5m
0m
15-
LEGEND - BUILDERS WORK Existing wall retained External cavity wall (Refer to wall types drawing) 100mm internal stud partition (See notes below) New 102.5mm thick brickwork 300mm thick party wall 140mm Blockwork wall (See notes below)
Beechworth House Single Storey - Approx. Extent
Mass concrete basement wall Refer to structural engineer's detail design
E
Beechworth House Single Storey - Approx. Extent
Beechworth House - Approx. Extent
Slab opening
AB
Floor recess
14
3
C1
15
2
10
100mmØ 1:60
ACO drain
16
D06 C1
F/A
Dining
400W X 460D RC Beam (below)
10
6
11
5
12
4
13
3
14
2
15
11
16
400W X 460D RC Beam (below)
9
8
Private stair 3
12
5
13
4
14
3
15
2
Patio
Patio
7
FR / FRZ
6
100mmØ 1:60
ACO drain
C1
ACO drain
F/A
400W X 460D RC Beam (below)
16
D/W
9
11
600W x 600D RC Beam (below)
500W x 600D RC Beam (below)
1
A
DUPLEX 1
B
WC
3
Hall
RWP 8 F/A
T/A
W02
100mmØ 1:60
ACO drain
RWP 9 F/A
UNIT 4,6,7,9,10
Open Lightwell
DUPLEX 3
D
RWP 4 T/B
RWP 3 T/B
Roof below Air Intake
SVP 3 (rises to terminal above upper roof)
NPA
07 12 16
SVP 8 DRAINAGE LINE REVISED
NPA
25 10900mm 16 above nearest opening
11
UTILITY RISER POSITION REVISED
NPA
07 10 16
10 FRONT GLAZING SIZE REVISED
NPA
30 08 16
09 REAR GLAZING REMOVED
NPA
18 08 16
08 LIGHTWELL OPENING AS BUILT
NPA
29 07 16
COLUMN POSITION AS BUILT
NPA
29 07 16
07 UNIT 2 HALL WALL RE-POSITIONED
NPA
21 07 16
06
STAIR CORE 1 REAR LINE REVISED
NPA
01 06 16
05
STAIR LANDING REVISION
NPA
10 05 16
04 RESIZED DRAINAGE CHANNEL
NPA
18 04 16
03 FRONT LIGHTWELL MOVED
NPA
18 04 16
02 DUPLEX 4 STAIR MOVED
NPA
14 04 16
01 FOR CONSTRUCTION
NPA
07 04 16
By
Date
Description
W16
Velux Roof light 780 x 1180mm
T/B
RWP 4 F/A Exhaust Air (MVHR) 1420mm distance from air intake
Flat Roof (Laid to falls) (Total area 109.4msq)
Ventilating pipe flue terminates
(Finished with perforated cover)
W16
RWP 3 F/A
Gutter line
Exhaust Air (MVHR)
Exhaust Air (MVHR) 905mm distance from air intake
Air Intake
125mmØ flue terminal
RWP 5 F/A
Gutter line
W16
Air Intake
Line of wall (Below)
SVP 5 F/B T/A
460mmØ distance from SVP 6
PV panel electric route to inverter TBC
Exhaust Air (MVHR)
SVP 2a F/B T/A 638mm distance from air intake
SVP 1 F/B T/A
AA 4
PV Panel (1) @ 0.333KWp @ 30 degree tilt
PV Panel (2)
PV Panel (3)
PV Panel (4)
PV Panel (5)
PV Panel (6)
PV Panel (7)
PV Panel (8)
PV Panel (09)
7
Velux Roof light 780 x 1180mm
SVP 6 F/B T/A
PV Panel (10)
PV Panel (11)
PV Panel (12)
PV Panel (13)
Air Intake 382mm distance from flue terminal
125mmØ flue terminal
SVP 4 F/B T/A
800mm distance from SVP 5 / 1500mm distance from boiler flue terminal
1650
SVP 8 F/B T/A
SVP 5 F/B T/A
4
1470mm distance from boiler flue terminal
3
05 Terrace (Laid to falls)
Terrace (Laid to falls)
Terrace (Laid to falls)
Terrace (Laid to falls)
2
2 RWP 6 82mmØ + Hopper
Roof below
Roof below
RWP 7 82mmØ + Hopper
RWP 8 82mmØ + Hopper
Roof below
04 03 02
RWP 9 82mmØ + Hopper
Roof below
01 Rev
GENERAL NOTES
1
GEN
This scheme is subject to Town Planning and all other necessary consents.
This s conse
Dimensions, areas and levels where given are only approximate and subject to site survey. All dimensions are to be checked on site. All feasibility studies are subject to full site survey.
Dimen subje feasib
This drawing is to be read in conjunction with all relevant consultants and/or specialists drawings/documents and any discrepancies or variations are to be notified to the architects in writing before the affected work commences.
1
E
Ground Floor
All qu to the
The workmanship and materials of all trades and building operations shall comply with the recommendations of British Standard (BS)8000 parts 1-16 inclusive and with Approved Document to support Regulation 7 1999 edition (incorporating 2000 amendments) of the Building Regulations 2010.
The w shall c parts Regul Buildi
2m
1.5m
1m
0.5m
0m
A
DUPLEX 8
B
DUPLEX 9
C
DUPLEX 10
D
DUPLEX 7
E
All de Const
Site
ZERO ALFRED ROAD LONDON W3 6LH
Site
Title
GENERAL ARRANGEMENT 10 UNIT GROUND FLOOR
Title
Scale @ A1
Scale @ 1:50 2.5m
This d and/o variat affect
1
All queries relating to design of structural elements are to be referred to the structural engineering consultant for resolution.
All design and construction is to be in accordance with the Construction (Design and Management) Regulations 2007.
Homes to make you happy Unit 3, 51 Derbyshire Street, London. E2 6JQ | +44 (0)20 7729 4189
Velux Roof light 780 x 1180mm
Gutter line
Velux Roof light 780 x 1180mm
CONSTRUCTION
Open Lightwell
DUPLEX 4
W16
RWP 3 T/B
878mm distance from air intake
12
Rev
Gutter line
RWP 1 F/A
5
13 UNIT 1 KITCHEN REVISED
WINDOW REVISED 26.08.16 (REFER TO DRAWING 15-02_707) Refuse store
Open Lightwell
C
2
D07
ACO drain
UNIT 3
DUPLEX 2
Living 600W x 600D RC Beam (below)
1
D07
100mmØ 1:60
UNIT 2,5,8
ACO drain
600W x 600D RC Beam (below)
Public stair 1
4
400W x 600D RC Beam
Services cupboard
Hall
7
W02 RWP 7 F/A
100mmØ 1:60
4
8
5
Dining
UNIT 4
Storage
9
6
Gas Meters
Fall 1:60 ACO drain
Gas Meters
100mmØ 1:60
Gas Meter
Refuse store
1
Refuse store
UNIT 1
BOXING REVISED TO SUIT NEW PROPOSED DRAINAGE LINE (25.10.16)
C1
W02
Fall 1:60
T/A
Open Lightwell
FR / FRZ
Living
C1
D07
W02
Kitchen
1
2
Gas Meters
D07
10
500W x 600D RC Beam (below)
C1
W01 RWP 6 F/A
2
Exhaust Air
0.13 W/m²K 0.15 W/m²K 0.12 W/m²K 0.18 W/m²K 1.4 W/m²K
DIMENSIONS TO BE VERIFIED ON-SITE - ANY DISCREPANCIES TO BE REPORTED TO DESIGN TEAM
400W X 460D RC Beam (below)
5
Services cupboard
Hall
2
Hall
16
Gas Meters
2
3
Living
11
Refuse store
WC
4
UNIT 2
Optional freestanding tv cabinet
Tall Storage FR / FRZ
5
Optional freestanding tv cabinet
Optional freestanding tv cabinet
Storage
C1
8 7
15
D/W 3
4
6
12
Storage
9
6
ROOF WALLS FLOORS PARTY WALLS WINDOWS -
13
Wine
Living
Storage
Storage
Public stair 1
Kitchen
4 3
11
15
Kitchen
12
10
14
Private stair 4
17 7
Storage
AA
13
14
13
D
C1
FR / FRZ
12
16
Storage
Coat Storage
400
/W
W in
e
Storage
14
C1
Dining
Fall 1:60
Bo
x 330
ile mm r
16 15
7
C1 10
8
Dining
17
Optional freestanding bookshelf
Storage
Roof below
125mmØ flue terminal
BUILDING ELEMENTS TO ACHEIVE U VALUES AS FOLLOWS:
D04
Kitchen
D/W
100mmØ 1:60
D05
RWP 1 T/B
THERMAL PERFORMANCE
RWP 5 F/A
RWP 2 T/B
NO 1 ALFRED ROAD
C1
9
Private stair 2
RWP 1 T/B
Fall 1:60
8
7
Lightwell (Frosted glass)
SLATE ROOF ANGLE TO BE SYMMETRICAL ON ALL THREE STAIR CORE PROJECTIONS
SVP 2b F/B T/A
Laid to fall
5
5 4
E
D
Fall 1:60
D06
Patio
7
6
12 13
6 Gutter line
DRAINAGE SHOWN INDICATIVE - SPECIALIST TO DESIGN AND SPECIFY DRAINAGE SYSTEM INCLUDING PUMPED DRAINAGE TO BASEMENT AND SURFACE WATER DRAINAGE
2958
8
Private stair 1
ACO drain
Below ground sewer
3
C
Fall 1:60
9
10
11
100mmØ 1:60
RWP 4 F/A
FOR DETAILS OF WALL TYPES REFER TO WALL TYPES DRAWING ISSUED SEPARATELY
991
W17
FULL WIDTH GLAZING INSTALLED (AS PER REVISED PLANNING PROPOSAL)
REAR STAIR CORE
Pile edge (below)
B
SVP 2b connection terminates above parapet wall
Drainage pipework
NOTE: Boxing required to accomodate horizontally terminating flue
Wine
Patio
2
RWP 3 F/A
SVP 2b 2b SVP T/B T/B
NO 1 ALFRED ROAD
RWP 2 F/A
F/A
Optional freestanding tv cabinet
RWP 1 F/A
Foul/surface water drainage Refer to drainage engineer's specialist scheme
REAR CONSTRUCTION TO BE LIGHTWEIGHT WALL WITH ADDED STEEL COLUMNS FOR SUPPORT (APPLIES TO ALL STAIR CORES)
Gas Meter
6
REAR STAIR CORE
871
REAR GLAZING MOVED TO SIDE / REPLACED WITH WALL 18 08 16
1
Fall 1:60
REAR STAIR CORE
Laid to fall
D
Fall 1:60
C
Laid to fall
B
Fall 1:60
AB
Laid to fall
Beechworth House - Approx. Extent
Roof
Checked
Date
Drawn
1:50
09 2016
NPA
Job No
Drawing No
Revision
C102
Homes to make you happy Unit 3, 51 Derbyshire Street, London. E2 6JQ | +44 (0)20 7729 4189
15-02
-
13
© 2016 UPLIFT PROPERTY LTD. All rights reserved.
Scale @
1:50
Scale @ 1:50 2.5m
2m
1.5m
Job No
1m
0.5m
0m
15-
'3 FELT TORCH ON MEMBRANE' ROOF FINISH
STAIR CORE 1
5
2
4
TORCH ON 3 LAYER MEMBRANE WITH FELT BASE
STAIR CORE 3
LINE OF ROOF BEAM
LINE OF ROOF BEAM
5
1
2
4
1
FLAT ROOF LAID TO FALL 1:80 FLAT ROOF LAID TO FALL 1:40 (SITE FALL 1:80)
SLAB THICKNESS AS PER STRUCTURAL ENGINEERS SPECIFICATIONS
26524 TOS
130 x 95mm OGEE GUTTER
26317 BOS MIN 150mm HIGH UPSTAND (Not cast as built, will need review on site) Screed laid to 1:80 fall
24879 TOS
23742 FFL
Render panel
23742 FFL
23648 SSL
23648 SSL
14
23400 CSL
11 10
'TRESPA' FACADE PANELS 1530 x 3050mm
9 8
8 7
Hall
6 5
Bathroom
Shared Bathroom
7
Dining
6 5
4
1
20732 SSL
17 17 16
16
15
15
20473 CSL
20473 CSL
14
14
13
13
12
12
ACO DRAIN SITTING ONTOP OF SLAB
11
11
10
10 9
9
Hall
8
7
82mmØ RWP 5
8 7
6
'TRESPA' FACADE PANELS 1530 x 3050mm
MANHOLE POSITION (TRUE POSITION TO BE CONFIRMED)
Living 6
CAPPING BEAM TO BE PLACED AS LOW AS POSSIBLE WITHOUT DISTURBING PUBLIC HIGHWAY CONTRACTOR AND PILING DESIGNER TO CO-ORDINATE
5
5
4
4
3
3
17894 FFL
2
2
1
1
17800 SSL
17894 FFL 17800 SSL
17 16 15 14
17551 CSL
12 11 10 9 8
Hallway
17551 CSL
MET-SEC LIGHTWEIGHT EXTERNAL WALL WITH BRICK FACADE (SUPPORTED BY ACON MDC NEXUS BRACKET)
13
7 6
Living
2
BOUNDARY DEFINED AS ℄ OF EXISTING WALL
20826 FFL
20732 SSL
1
20724 SSL
14
17 16
13
15
12
14
11
13
10
12
9
11 10
8
9
7
8
Shared Hall
6 5 4
7 6 5 4
3
3
2
2
1 17
17799 SSL
16 15 14 13 12
TOP SLAB (WITH PAVING SLAB) LAID TO 1:60
11 10 9
NEW CAVITY PARTY WALL TO EXTEND TO 2.100M EGL
7 5
4
1
15
13 12
12
7
13110 CAPPING BEAM LEVEL
6 5 4 3
TRANSFER BEAM TO BE DESIGNED BY ENGINEER TO SUPPORT BRICKWORK ABOVE
10 9
CONCRETE STRIP FOOTING TO REPLACEMENT PARTY WALL CONTRACTOR TO DESIGN APPROPRIATE RC WALL OR COLUMNS TO SUPPORT GROUND FLOOR WHERE CAPPING BEAMS ARE BELOW GROUND FLOOR LEVEL
2 1
7 6 5 4 3
5
4
5
2
02
STAIR S
Rev
Descripti
C
GENERAL N
1
This scheme is consents. Dimensions, are subject to site s feasibility studi This drawing is and/or speciali variations are t affected work c All queries rela to the structura The workmansh shall comply wi parts 1-16 inclu Regulation 7 19 Building Regula All design and c Construction (D
4
2
1
SECTION A-A
THIRD
EXTERNAL FLOOR LAID TO 1:50 FALL
11423 SSL
65mm SCREED
ANGL
03
01 FOR C
ACO DRAIN TO RUN FULL LENGTH
2
11581 FFL
11435 SSL
8
Column wall (Behind)
8
Column (Behind)
10 9
11
Column wall (Behind)
11
04 14770 CAPPING BEAM LEVEL
14
14337 EGL Column (Behind)
14416 CSL (Internal behind)
1 16
14600 CSL
14 13
TERRA
05 WINDO
2
14875 SSL
16 15
Ceiling slab line behind
3
14969 FFL
2
14600 CSL
06
4 3
14875 SSL
LINE OF LIGHTWELL OPENING (BEHIND)
6
5
14969 FFL
07 ROOFL
8
Column (Behind)
Bathroom
(ENGINEER/METSEC SUPPLIER TO DESIGN IN ABEYANCE)
3 2
20826 FFL
17749 TOS
SECOND FLOOR ORIEL WINDOWS TO BE CONSTRUCTED FROM STRUCTURAL METSEC FRAMING SUPPORTED OFF SECONDARY STEELWORK.
Bedroom 1
4 3
20674 TOS
GUTTER LINE
13 12
23400 CSL
11 10 9
1700mm FROSTED BALUSTRADE
14
23649 SSL
13 12
NOTE INTERN INDIC
INSULATION DETAIL TO BE WORKED OUT IN ABEYANCE
Bedroom 3
130 x 95mm OGEE GUTTER
310mm HIGH PARAPET WALL (500mm High from slab)
130 x 95mm OGEE GUTTER
23849 TOS
DOOR TYPE / DETAIL TO BE WORKED OUT IN ABEYANCE
82mmØ RWP 5
Site
Z L W
Title
S 1
1
SECTION B-B
Cross Sections Scale @ A1
1:50
Scale @ 1:100
Homes to make you happy Unit 3, 51 Derbyshire Street, London. E2 6JQ | +44 (0)20 7729 4189
5m
4m
Job No
3m
2m
1m
0m
15-02
Feature Window Pods
C
D
E
SVP 4 SVP 5
SVP 6 SVP 7
SVP 8
K-Rend or similar approved textured render finish colour - polar white to match reder panels to rear and flank walls
SVP 2a
Flat roof laid to fall 1:40 with raised edge trim
5
2
4
Balustrade Frosted glazing
1
SVP 8
SVP 1
B
SVP 4 SVP 1
Balustrade Frosted glazing
SVP 2a
A
SVP 6 SVP 5
Line of roof beam
Third floor doors: Dark grey powder coated aluminium cladding to surrounds with double-glazed sliding doors in dark grey aluminium powder coated frames
SVP 3
SVP flue: Soil pipe flue terminating 900mm above nearest domestic opening
26524 TOS
26524 TOS
Third floor Internal Ceiling 26317 BOS
26317 BOS
Render
Render
Sliding door
Render
Sliding door
Render
Sliding door
Render Panels To be white render-style rainscreen cladding boards by Trespa or similar approved
1700
Sliding door
Roof Terrace FFL
Roof Terrace FFL
23648 SSL
Line of Slab edge
Line of Slab edge
Side hung Fixed
Fixed Fixed
Side hung (Safety glass)
Fixed
Fixed
Render Panel
First Floor FFL
250 Fixed
Brick
(Secured by design)
Side hung
Brick
Side hung
(Secured by design)
Side hung
Side hung
(Secured by design)
Side hung
Side hung
Fixed
Fixed
Fixed
20724 SSL
Facade 'TRESPA' External facade panel 1530 x 3050mm 17799 SSL
Fixed
Panels to open as per window specialist specifications
Brick
Render
External SVP 2b location Brick
(Safety glass)
Side hung
Fixed
(Safety glass)
Fixed
Side hung (Safety glass)
Fixed
AOV feature window
Side hung (Safety glass)
Fixed
(Safety glass)
Side hung
Fixed
(Safety glass)
Fixed
Fixed
(Safety glass)
Side hung
Side hung (Safety glass)
(Safety glass)
Fixed
Fixed
Side hung (Safety glass)
Fixed
Side hung (Safety glass)
Fixed
AOV feature window
Side hung Side hung
(Secured by design)
Fixed
Side hung Fixed
Fixed
Brick
Brick
ALL GROUND FLOOR WINDOW REVISED 18 08 16
17799 SSL
'TRESPA' FACADE PANELS 1530 x 3050mm
Brick
Brick
Brick
Brick
Brick
Transparent safety glazing (1.1m high)
Ground Floor FFL
14874 SSL
14874 SSL
Line of Slab edge
250
Ground Floor FFL
Side hung
Brick
Canopy Light grey powder coated aluminium cladding
(Secured by design)
Timber front door
Brick
Drainage External RWP 1 location
Brick
Line of Slab edge
Render
Second Floor FFL
20724 SSL
Brick
(Safety glass)
Fixed
Side hung
(Safety glass)
Fixed
Brick
(Safety glass)
Fixed
Side hung (Safety glass)
Fixed
Side hung casement windows All outward opening with restrictor hinge (apart from special AOV feature windows)
Render
Brick Outer Walls Funton Stock or similar to compliment London Stock of neighbours brick
(Safety glass)
Side hung
Fixed
(Safety glass)
Fixed
Fixed
Fixed
Fixed
Side hung
Fixed
(Safety glass)
Fixed
250
Brick Outer Walls Funton Stock or similar to compliment London Stock of neighbours brick
Fixed
Fixed
Side hung (Safety glass)
Fixed
Fixed
Second Floor FFL
First Floor FFL
AOV feature window
Side hung Fixed
Fixed
(Safety glass)
RWP
Fixed
Double-glazed windows Grey aluminium powder coated frames (Toughened / safety glass)
23648 SSL
Third floor FFL 250
Third Floor FFL
Render Panel
BOXING WILL CAUSE LIGHTWELL OVERLAP. WILL NEED CONSIDERING
Basement Internal Ceiling Lightwell Walls Brilliant white render finish Render
(Secured by design)
Bi-fold door
(Secured by design)
Bi-fold door
Render
(Secured by design)
Bi-fold door
Render
(Secured by design)
Bi-fold door
(Secured by design)
Bi-fold door
(Secured by design)
Bi-fold door
(Secured by design)
Render
Bi-fold door
Bi-fold door
Basement Floor FFL
Blockwork Separating Walls Brilliant white render finish
(Secured by design)
BI-FOLD DOOR CHANGED TO SUIT INTERIOR USE
Bi-fold door system
Basement Floor FFL
11423 SSL
Front entrance Slab laid at 1:60 fall to gutter (Fall towards road) Front entrance Slab laid at 1:60 fall to gutter (Fall towards building)
A
B
C
D
5
E
FRONT (EAST) ELEVATION
2
4
1
NORTH ELEVATION
Roof Lead flashing / aluminium trim on edge of roof
Flat roof laid to fall 1:80
B
AB
Gutter line
2
1
Beechworth House (part covering 0 Alfred Road)
26524 TOS
Roof Redland Cambrian Slate colour - slate grey
4
Balustrade Frosted glazing
5
Render Panels To be white render-style rainscreen cladding boards by Trespa or similar approved
SVP 5 SVP 6
Gutter line
SVP 2a
C
Gutter line
SVP 1 SVP 4
D
SVP 8
E
Third floor Internal Ceiling Side hung Fixed
WINDOWS REDUCED AND RAISED TO SUIT NEW FACADE EDGE
Render Panel
RWP
(Safety glass)
RWP
Fixed
Render Panel
(Safety glass)
Side hung
Side hung Fixed
RWP
(Safety glass)
RWP
Fixed
Render Panel
(Safety glass)
Side hung
26317 BOS
Electronic Aluminium double glazed roof light Dark grey powder coated with AOV feature (940 x 1180mm) 23648 SSL
Gutter
Roof Terrace FFL
Gutter
Render
Side hung
Double-glazed windows Toughened / safety glass (with render finish)
(Safety glass)
Fixed
(Safety glass)
(Safety glass)
Fixed
Fixed
Side hung
Fixed
(Safety glass)
Side hung (Safety glass)
Fixed
Fixed
(Safety glass)
Side hung
Fixed
(Safety glass)
Side hung (Safety glass)
Side hung (Safety glass)
Fixed
Fixed
Side hung
Brick
(Safety glass)
Fixed
Fixed
(Safety glass)
Side hung
250
Brick Outer Walls Funton Stock or similar to compliment London Stock of neighbours brick
Render Panel
Panels to open as per window specialist specifications
Second Floor FFL
20724 SSL
Roof Terrace FFL Third floor FFL
23648 SSL
Third Floor FFL
Brick
20724 SSL
Second Floor FFL
250
Render
(Safety glass)
Fixed
(Safety glass)
Fixed
Side hung
Side hung
Brick
(Safety glass)
Side hung
Render Panel
Fixed
1150
Side hung
Space open to elements
Render Panel 1150
Side hung (Safety glass)
(Safety glass)
Fixed
Fixed
Side hung (Safety glass)
Brick
Fixed
Side hung (Safety glass)
Fixed
(Safety glass)
Fixed
Side hung
Brick Render Panel
Double-glazed windows Grey aluminium powder coated frames
Privacy screen Frosted glazing for privacy as per planning instruction
Brick
First Floor FFL
First Floor FFL
17799 SSL
Bi-fold door
Wall to be re-built
Bi-fold door
Bi-fold door
Bi-fold door
250
17799 SSL
New RWP Set in front of facade features (Running into ACO gutter below)
GROUND FLOOR GLAZING REMOVED 18 08 16
250
BALCONY APPEARANCE REVISED TO SUIT PLANNING SPECIFICATIONS
Brick
Brick Ground Floor FFL Ground Floor SSL
14874 SSL
Ground Floor FFL
14874 SSL
Basement Internal Ceiling
Basement Floor FFL
11423 SSL
Basement Floor
Basement Floor SSL
External Elevations
E
REAR (WEST) ELEVATION
D
C
B
AB
1
2
SOUTH ELEVATION
4
5
40
100
15
30
18
100
30
40
15
100
250 15
10
15
15
10
10MM SKIMMED PLASTER / PAINT FINISH 60 I 70 GYPFRAME STUD
60 I 70 GYPFRAME STUD
60 I 70 GYPFRAME STUD
10MM SKIMMED PLASTER / PAINT FINISH
60 I 70 GYPFRAME STUD
50MM ISOVER APR1200 OR SIMILAR
2 X 15MM GYPROC SOUNDBLOC TAPE AND JOINTED, 3MM SKIMMED
15MM TILE FINISHES ZONE (WHERE REQUIRED) MAPEI 'ULTRACOLOUR PLUS' GROUT BETWEEN TILES
2 X 15MM GYPROC SOUNDBLOC TAPE AND JOINTED, 3MM SKIMMED
50MM ISOVER APR 1200 OR SIMILAR
50MM ISOVER APR 1200
50MM ISOVER APR 1200
CAVITY (DEFINED BY COLUMN)
1 X 15MM GYPROC SOUNDBLOC TAPE AND JOINTED
1 X 15MM GYPROC SOUNDBLOC TAPE AND JOINTED
CAVITY (DEFINED BY COLUMN)
18MM FSC WBP PLYWOOD STRENGTHENING
92
12.5
12.5 2 X 12.5MM GYPROC WALLBOARD TAPE AND JOINTED, 3MM SKIMMED 20MM T&G ENGINEERED TIMBER FLOOR BOARDING OVER 6MM UNDERLAY
300MM R.C. WALL TO STRUCTURAL ENGINEERS DETAIL
2 X 15MM GYPROC SOUNDBLOC MR 2 X 15MM GYPROC SOUNDBLOC TAPE AND JOINTED, 3MM SKIMMED
125 8
STRUCTURAL COLUMN
CAVITY (DEFINED BY COLUMN)
18MM FSC WBP PLYWOOD BASE NAILED TO JOISTS
75MM SAND CEMENT SCREED WITH ANTI-CRACK MESH (OR APPROVED FIBRE MESH)
FFL
6 20
100
15
300
240
20MM HORIZONTAL CAVITY DRAIN MEMBRANE (CDM) (FULLY SEALED TO VERTICAL CDM, WITH SAND FILLED DIMPLES TO UPPER SIDE PRIOR TO LAYING INSULATION) R.C. SLAB TO STRUCTURAL ENGINEERS DETAILS
50
15
30
6 18
15
333
230
3
20
75
30
8MM VERTICAL CAVITY DRAIN MEMBRANE FIXED WITH NUSEAL OR SIMILAR PLUG FIXINGS WITH WATERSEALS TO PROVIDE COMPRESSION SEAL AND FIXING OF: 92 X 50MM GYPFRAME CHANNELS 50MM MIN. CELOTEX TB3000 INSULATION WITH TAPED JOINTS TO CREATE VAPOUR CONTROL LAYER TO PERIMETER PROVIDE SEALANT TO PERIMETER OF INSULATION
50
240
145
300
DUPLEX 1 BEDROOM 2 INTERIOR
DUPLEX 1 EN-SUITE INTERIOR
DUPLEX 2 BEDROOM 1 INTERIOR
DUPLEX 2 BEDROOM 1 INTERIOR
DUPLEX 2 BEDROOM 2 INTERIOR
DUPLEX 3 BEDROOM 1 INTERIOR
PERIMETER DRAINAGE CHANNEL / CAST IN PIPE TO BASEMENT SPECIALIST DETAIL DRAINAGE CONNECTED TO AND PUMPED TO EXISTING COMBINED FOUL / SW SYSTEM
BASE
NOTE: TO BE INSTALL BY APPROVED SUB-CONTRACTOR
PARTY WALL - W01
1
Rw + Ctr 52dB fire 60 min U-value 0.23W/m2K
General internal party wall
PARTY WALL - W02
2
Rw + Ctr 52dB fire 60 min
General interior party wall to bathroom
3
PARTY WALL - W03
Rw + Ctr 52dB fire 60 min U-value 0.23W/m2K
General internal party wall through column
BASEMENT WALL
4
Typical basement retaining wall
5 MS01
284 (Trespa bracket size TBC)
344 215 103
100 50
50
12
100
30 15
138 10
15
26 TBC 50
100
104 30 30
104
30 15
25 15
12.5
50 12.5 50
138 25
25
25
25
68 18
50
30.5 18
15
M
GRO
12.5 15
MIN. 50MM CAVITY 30MM SHEATHING BOARD FIXED TO FRAMING
20
100M12 METSEC STUD @600MM CENTERS WITH 104M20 HEAD/BASE TRACKS
100M12 METSEC STUD @600MM CENTERS WITH 104M20 HEAD/BASE TRACKS
2 X 15MM GYPROC SOUNDBLOC TAPE AND JOINTED, 3MM SKIMMED
BOUNDARY LINE
20
100MM CELOTEX FR5000 INSULATION BETWEEN STUDS (OR SIMILAR)
10MM 'TRESPA METEON' FACADE PANEL
METSEC EXTERNAL WALL - MS01 fire 60 min
5
U-value 0.23W/m2K
External masonary metsec wall type
METSEC EXTERNAL WALL - MS02 fire 60 min
6
U-value 0.24W/m2K
External slate cladding metsec wall type
INTERIOR
7
DUPLEX 1 BEDROOM 2 INTERIOR
INTERIOR
PARTITION - W04
Rw 40dB fire 30 min
General internal partition
38 X 38MM COUNTER-BATTENS
3 LAYER BITUMEN TORCH ON MEMBRANE
RIGID INSULATION OVER RAFTERS
3G BASE LAYER
BREATHABLE SARKING MEMBRANE 'KINGSPAN NILVENT' OR SIMILAR
15
250
38 62
125
ANCON IHR HEAD RESTRAINT (OR SIMILAR) CENTRALISED ON SLAB
377
9.9
MDC/P/NB BRACKET 30/20 POST FIXED (OR SIMILAR)
350 100 9.9
FCL
70
MIN. 13MM AIR SPACE ABOVE INSULATION
U-value 0.15W/m2K
Wall Construction Sections Homes to make you happy Unit 3, 51 Derbyshire Street, London. E2 6JQ | +44 (0)20 7729 4189
10
PITCHED ROOF DETAIL Typical detail - Unventilated roof
U-value 0.15W/m2K
100MM CELOTEX FR5000 INSULATION BETWEEN STUDS
50
30
281 30
100
30
HELPING HAND BRACKETS FIXED TO STUDS THROUGH SHEATHING BOARDS BRACKET FIXING WILL NEED TO BE EXTRA LONG TO FACTOR IN INSULATION THICKNESS EOS 'SS10012' 100mm WIDE SWAGED STUD @600MM CENTERS SHEATHING BOARD FIXED TO FRAMING EOS 'T10012' 100mm WIDE BASE TRACK
30MM'CELOTEX TB4030' FOIL FACED RIGID INSULATION BOARD DPC VAPOUR BARRIER EOS 'DHT100' 100mm WIDE HEAD TRACK BOUNDARY LINE
ANCON MDC NEXUS SOFFIT SYSTEM (OR SIMILAR)
130MM KINGSPAN KOOLTHERM K7 PITCHED ROOF BOARD BETWEEN RAFTERS
NOTE: DESIGN FALL OF 1 IN 80
Typical detail - Cold flat roof
ANCON MDC BRACKET ANGLE SUPPORT SYSTEM (OR SIMILAR)
50MM WIDE RAFTERS AT 424MM CENTERS
MIN. 13MM AIR SPACE ABOVE INSULATION
FLAT ROOF DETAIL
STEEL BEAM 12.5MM GYPROC SOUNDBLOC TAPE AND JOINTED, 3MM SKIMMED
100MM CELOTEX GA4100 INSULATION BOARD BETWEEN RAFTERS
26
3050x1530mm EXTERNAL 'TRESPA METEON' FACADE PANEL
EOS 'SS10012' 100mm WIDE SWAGED STUD @600MM CENTERS WITH 100mm 100MM CELOTEX FR5000 INSULATION BETWEEN STUDS (OR SIMILAR)
FCL
12.5
12.5
9.9
100
207
87
VAPOUR BARRIER
50MM WIDE RAFTERS AT 600MM CENTRES
9
'ROCKWOOL' 70X75MM FIRE BREAK DPC
20
17 100 9.9 87
377 207
FCL
10 10MM SPACE BETWEEN PANELS
30MM'CELOTEX TB4030' FOIL FACED RIGID INSULATION BOARD
125
VAPOUR CONTROL LAYER
VAPOUR BARRIER 100MM STOCK BRICK
Rw 40dB fire 30 min
General internal partition to bathroom
2 X 15MM GYPROC SOUNDBLOC TAPE AND JOINTED, 3MM SKIMMED
50
TILE BATTENS
25mm CEILING JOISTS TO ALLOW FOR 1:80 FALL
DUPLEX 1 EN-SUITE INTERIOR
PARTITION - W05
8
BRICK-TIES AT 225MM VERTICAL CENTERS ROOF TILES
100MM TORCH RECEIVABLE INSULATION
STEEL BEAM 12.5MM GYPROC SOUNDBLOC TAPE AND JOINTED, 3MM SKIMMED
18MM FSC WBP PLYWOOD PATRESS
ROO
INTERIOR
20
EXTERIOR
15MM TILE FINISHES ZONE (WHERE REQUIRED) MAPEI 'ULTRACOLOUR PLUS' GROUT BETWEEN TILES
18MM FSC WBP PLYWOOD PATRESS + SERVICE SUPPORT PLATE IN SPECIFIED AREA
HELPING HAND BRACKETS FIXED TO STUDS THROUGH SHEATHING BOARDS
INTERIOR
12.5MM GLASROC H TILEBACKER BOARD TAPE AND JOINTED
WALL BRACKET FIXED TO STUD THROUGH SHEATHING BOARD
BRICK-TIES AT 225MM VERTICAL CENTERS
EXTERIOR
18MM FSC WBP PLYWOOD PATRESS + SERVICE SUPPORT PLATE IN SPECIFIED AREA
30MM'CELOTEX TB4030' FOIL FACED RIGID INSULATION BOARD
20
50MM KINGSPAN 'THERMAWALL TW55' WITH S/S FIXINGS TO BRICK TIE CHANNELS BRICK-TIE CHANNELS TYPICALLY AT 1200MM HORIZONTAL CENTERS FIXED TO STUDS WITH STAND-OFF SCREWS
48MM GYPFRAME C STUDS 2 X 12.5MM GYPROC WALLBOARD TAPE AND JOINTED, 3MM SKIMMED
2 X 12.5MM GYPROC WALLBOARD TAPE AND JOINTED, 3MM SKIMMED
EOS 'SS10012' 100mm WIDE SWAGED STUD @600MM CENTERS
311
11
ANCON BRACKET WITH FIRE BREAK Typical detail fixed to slab
U-value 0.14W/m2K
250
100MM CELOTEX FR5000 INSULATION BETWEEN STUDS (OR SIMILAR)
48MM GYPFRAME C STUDS 2 X 12.5MM GYPROC WALLBOARD TAPE AND JOINTED, 3MM SKIMMED
20
2 X 15MM GYPROC SOUNDBLOC TAPE AND JOINTED, 3MM SKIMMED
20
12MM CEMENT BONDED PARTICLE BOARD AND POLYTHENE VAPOUR CONTROL LAYER
12
MET-SEC WALL ON SLAB Typical detail on slab
FCL
U-value 0.24W/m2K
Triple glazed casement window
50
30
51
Aluminum Window Cill
329 100
30 30
12 100
12
100mm stock brick
100mm insulation between studs Sheathing board fixed to framing
Timber floor finish
Foil faced rigid insulation board
Flush finish mortar
x 2 Plasterboard DPC
664
571
Cavity
Foil faced rigid insulation board
Helping hand brackets fixed to studs through sheathing boards
100mm insulation between studs
Timber floor finish
x 2 Plasterboard
Boundary line
Skirting board
Skirting board
250
'Rockwool' 100x75mm fire break
SD21 Tie Length to suit cavity / masonry (set at 450mm intervals)
125
125
Vapour barrier
240
475
350
ANCON IHR head restraint
MDC/P/NB bracket 30/20 cast in channel if not cast systems can be post fixed (see ancon for further information) Ancon MDC bracket angle support system
Ancon MDC nexus soffit system
Triple glazed casement window
TYPICAL EXTERIOR SECTION - FRONT Scale 1:10 Wall Construction Sections
Homes to make you happy
TYPICAL EXTERIOR SECTION - REAR Scale 1:10
Hand Sketch
Meeting Sketches
Meeting Sketches
Mansard Roof Detail
Basement Extension Detail
Rendering Example
General Arrangment
General Arrangment
Pontoon Details
Plan / Front Elevation
Section Details
Bathroom Details
Bathroom Details
Bathroom Details
Plan, Section, Elevation
Fireplace Details
Terrace and Bathroom Finished Examples