Example Project- Restaurant

Page 1

2

12174

255

PL-DR-EX-XX-52

1 PL-DR-EX-XX-53

0.5

0

SCALE 1: 50

1378

1425

992

1324

861

Staff Changing

4235

Room

1.5

2

2.5 m

2196

Passage 3122

1567

4001

3941

4043

2288

466

944

Stairs

927

5919

246

Cold Store 2264

760

1490

956

3238

131

377

857

247

8745

2021

3414

140

0

Kitchen 6415

Cold Store

927

4702

870

4230 1848

1130

800

1

1440

275 1470

761

0.5

1390

393

1702

285

2330 170

378 170

2775

170

Guest WC

200

260

157

1943

686

PL-DR-EX-XX-52

100

900

2070

480 72

870

1368

11972

3396

3345

2952

3416

21462

2310

5860

PL-DR-EX-XX-53

92 310

108 621

621 193

Guest Seating

721

128

570

118

66 30

12612

Front of Shop 5720

43

3421 985

4406

3355 1051

580

707

5620

580

57 615

3660

3660

3497

3533

5723

1500

1500

121

21838

3070

2

Store 1020

1037

1

170

146

1037

Guest WC

Occasion Seating

2638

3260

5777

5660

866

255

100

Client : Ijas Hussain / Muhammad Irfan 1600

20

11815 12325

1600

100

1327

50 255

Project : 1538-1540 London Road,

Streatham, London, SW16 4EU Drawing : Existing Ground Floor Plan

1

0.1 Existing Ground Floor 1 : 50

Scale : 1 : 50 Date : 10/18/20

Status : Planning

Rev :

Dwg No : PL-DR-EX-00-01

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


2 PL-DR-EX-XX-52

First Floor 3650 0.5

0

0.5

1

SCALE 1: 50

Occasion Seating

Kitchen

Guest WC

Kitchen

1.5

2

2.5 m

Store

Refelected Ceiling Plan

0 Garden LVL -600

1

Existing Section 1 1 : 50

1 PL-DR-EX-XX-52

First Floor 3650

Guest Seating

Occasion Seating

Cold Store

Staff Changing

Refelected Ceiling Plan

0

Client : Ijas Hussain / Muhammad Irfan

2

Existing Section 2 1 : 50

Project : 1538-1540 London Road,

Streatham, London, SW16 4EU Drawing : Existing Sections Scale : 1 : 50 Date : 10/18/20

Status : Planning

Rev :

Dwg No : PL-DR-EX-XX-52

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1 PL-DR-EX-XX-52

First Floor 3650

Kitchen

Guest WC

Guest WC

0.5

0

0.5

1

1.5

2

2.5 m

SCALE 1: 50

Front of Shop

Refelected Ceiling Plan

0

Existing Section 3

1

1 : 50

First Floor 3650

Guest Seating

Front of Shop

Refelected Ceiling Plan

0

Client : Ijas Hussain / Muhammad Irfan Project : 1538-1540 London Road,

Streatham, London, SW16 4EU

2

Existing Section 4

Drawing : Existing Sections

1 : 50 Scale : 1 : 50 Date : 03/16/21

Status : Planning

Rev :

Dwg No : PL-DR-EX-XX-53

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


Staff Changing Kitchen

Passage

Stairs

Cold Store

Cold Store

Kitchen Guest WC Occasion Seating Guest WC

Guest Seating

Kitchen

Store

Front of Shop

Client : Ijas Hussain / Muhammad Irfan Project : 1538-1540 London Road,

Streatham, London, SW16 4EU

1

Refelected Ceiling Plan 1 : 50

Drawing : Existing Ceiling Plan Scale : 1 : 50 Date : 03/16/21

Status : Planning

Rev :

Dwg No : PL-DR-EX-XX-54

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1538-1540 London Road - Design Presentation

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Design Presentation Title

Scale : Date :

Status : Draft Design 09/11/20

Rev :

Dwg No : DX-DR-OP0-00-00

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


Ground Floor 3-Dimensional Design- Option 1

Contains 1 no. 3-D Plan + 2 no. 3D Isometrics + 8 no. Internal 3-D Visuals Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor 3-Dimensional Design- Option 1 Title

Scale : Date :

Status : Draft Design 09/11/20

Rev :

Dwg No : DX-DR-OP1-00-10

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


Fire Exit

Fire Exit

Office/CCTV room Changing Room

Staff WC

4x Pot Burners

Ration Racks/ Ration Racks/ Store Store

Utensils and Appliance storage

4x Hob Burners

Fruit and Veg Racks

Hand Wash

Prep Table

Kitchen

Dry Store

Ration Racks/ Ration Racks/ Store Store Food Washing

Store

Drinks Store

Drinks Store

Utensils and Appliance storage

Cutlery Racks

?

Cutting Table with waste basket below

Seating for 10x

Fruit and Veg Racks

Seating for 10x

Hand Dryer

Passage

Fire Door with Vision Panel

floor trap

Fire Door with Vision Panel

Deep Bowl Washing Sink

Freezer 130 3 m²

Drying Racks

Guest WC Corridor 400

Guest Hand Wash

Store

Guest WC

Hand Dryer

Door with Vision Panel

Drinks Cabinet

Cash Register

Juice Bar

1288

Guest Seating

450

Prep table

Hand washing sink

1406

46 62

4x 20 Seating

8x Hobs

1518

Guest Seating

Deep Bowl Washing Sink

28 144 m²

2500

1355

1200mm Grill plate

Display unit 900

Prep table

883

600

Tandoor

883

8

???

Tandoor

Display unit

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

415

2500

1045

Client :

600

Fire Exit

1800

Prep table

OP1- Proposed Ground 1 Floor 1 : 30

1 PL-DR-PR-RL-13

Ground Floor Design Option 1 in 3D- Plan

Scale : 1 : 30

Status : Draft Design

Date :

Dwg No : DX-DR-OP1-00-20

09/11/20

Rev :

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com

Existing Entrance to be © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to Blocked the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor Design Option 1 in 3D- Isometric 1

Scale : Date :

Status : Draft Design 09/11/20

Rev :

Dwg No : DX-DR-OP1-00-30

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


Op1- Ground Floor Isometric 1 2

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor Design Option 1 in 3D- Isometric 2

Scale : Date :

Status : Draft Design 09/11/20

Rev :

Dwg No : DX-DR-OP1-00-31

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1

2

3D Visual

3D Visual 1

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor Design Option 1 in 3D- Internal Views

Scale : Date :

Status : Draft Design 09/11/20

Rev :

Dwg No : DX-DR-OP1-00-35

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1

2

3D Visual 2

3D Visual 3

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor Design Option 1 in 3D- Internal Views

Scale : Date :

Status : Draft Design 09/11/20

Rev :

Dwg No : DX-DR-OP1-00-36

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1

2

3D Visual 4

3D Visual 5 (Private Dining)

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor Design Option 1 in 3D- Internal Views

Scale : Date :

Status : Draft Design 09/11/20

Rev :

Dwg No : DX-DR-OP1-00-37

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1

2

3D Visual 6

3D Visual 7

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor Design Option 1 in 3D- Internal Views

Scale : Date :

Status : Draft Design 09/11/20

Rev :

Dwg No : DX-DR-OP1-00-38

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1

1

C-2.3

C-2.4 2

Fire Exit

Fire Exit

C-5.1

SYMBOLS HL HL

Office/CCTV room Changing Room

LOW LVL

LOW LVL

Staff WC

4x Pot Burners

LOW LVL

4x Hob Burners

LOW LVL 1

SWITCHED SINGLE SOCKET OUTLET @450MM HT

Fruit and Veg Racks

C-3.1 2 C-2.3 Ration Racks/ Ration Racks/ Store Store

Utensils and Appliance storage

UNSWITCHED SINGLE SOCKET OUTLET @450MM HT

Fruit and Veg Racks LOW LVL

SWITCHED DOUBLE SOCKET OUTLET @450MM HT

HL LVL

SWITCHED DOUBLE SOCKET OUTLET @750MM/1200MM HT (WITH USB CABLE CONNECTION TO CLIENT CHOICE)

Utensils and Appliance storage

Dry Store

Store

Drinks Store

42A UNSWITCHED SINGLE SOCKET OUTLET @450MM HT

Passage

Hand Wash

Ration Racks/ Ration Racks/ Store Store LOW LVL

Prep Table

Kitchen

Fire Door with Vision Panel

Food Washing

LOW LVL

REF.

Drinks Store

KITCHEN SPUR / FAN ISOLATOR

42A UNSWITCHED SINGLE SOCKET OUTLET @ FLOOR

Fire Door with Vision Panel

GRID SWITCH FOR APPLIANCES T

SPUR WITH TIMER

LOW LVL

TELEPHONE RJ45 Cutlery Racks

LOW LVL

REF.

?

LOW LVL

REF.

FRZ LOW LVL

LOW LVL

Cutting Table with waste basket below

LOW LVL

WI FI

Deep Bowl Washing Sink

Freezer

3 m²

C-3.1

GAS PIPE

Drying Racks

25MM ⌀ GAS PIPE

4 C-3.1

Seating for 10x

HL

Seating for 10x

Hand Dryer

GAS LEGEND

130

3

GAS PIPE UNDER FLOOR

Guest WC Corridor

Guest Hand Wash Store 2 C-2.1

Guest WC 2

ELEC CONSUMER UNIT

LOW LVL

C-3.1

Hand Dryer Door with Vision Panel

5 C-3.1 LOW LVL

1

Cash Register

LOW LVL

HIGH LEVEL

C-5.1

HIGH LEVEL

Juice Bar

LOW LVL LOW LVL

Prep table

Hand washing sink

4x 20 Seating

LOW LVL

Deep Bowl Washing Sink

42A

4x Hobs

Grill with 4x hobs

1

Prep table

C-2.1

Display unit LOW LVL

42A PLUG SPARE

Tandoor

Display unit

Fire Exit

LOW LVL

Ground Floor - Electrical 1 Plan 1 : 30

SOCKET FOR DOOR 1 HEATER/AIR CURTAIN PL-DR-PR-RL-13

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Tandoor

Drawing :

LOW LVL

T

Client :

Prep table

Existing Entrance Blocked

Ground Floor - Electrical & Gas Supply Plan

Scale : As indicated

Status : Draft Design

Date :

Dwg No : C-1.0

03/31/21

Rev :

DESIGNLABS LONDON ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com to be © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


SYMBOLS UNSWITCHED SINGLE SOCKET OUTLET @450MM HT SWITCHED SINGLE SOCKET OUTLET @450MM HT LOW LVL

SWITCHED DOUBLE SOCKET OUTLET @450MM HT

HL LVL

SWITCHED DOUBLE SOCKET OUTLET @750MM/1200MM HT (WITH USB CABLE CONNECTION TO CLIENT CHOICE) KITCHEN SPUR / FAN ISOLATOR 42A UNSWITCHED SINGLE SOCKET OUTLET @450MM HT 42A UNSWITCHED SINGLE SOCKET OUTLET @ FLOOR GRID SWITCH FOR APPLIANCES

T

SPUR WITH TIMER TELEPHONE RJ45 WI FI

ELECTRICAL NOTES

INTERNAL DOOR NOTES

Electrical work shall be carried out by a competent person or contractor with self certification. Wiring work shall be carried out in accordance with all current regulations including IEEE Wiring Regulations (BS 7671:2005) All emergency lighting to be designed and installed in accordance with BS EN1838 & BS 5266 (1999). All Socket outlets to be RCD protected (Excluding till equipment Power Sockets) at the distribution board. Fire Alarm system to be designed in accordance with British Standard 5839 Part 1 & Installed by Approved Contractor. Any alterations to the fire alarm system will be in accordance with BS5839 Part 1.2002 Any alterations to the emergency lighting system will be in accordance with BS5266 Part 1 Reasonable provision shall be made in the design and installation of electrical installations in order to protect persons operating, maintaining or altering the installations from fire or injury. In addition, electrical installation work must comply with the Building Regulations in general. Such requirements include those placed by: • Part A - Structure • Part B - Fire Safety • Part C - Site preparation and resistance to moisture • Part E - Resistance to the passage of sound • Part F - Ventilation • Part L - Conservation of Fuel and Power • Part M - Access to and use of buildingsSee lighting specs - Last man out switch and single time clock. M&E contractor designed electrical systems layout. Indicative layout shown on plans to establish main EE requirements only. Any existing distribution boards, supply and installation to be inspected and upgraded or replaced as necessary. Electrical commissioning certificate to be provided to employer upon completion.

All new internal corridor and room door sets are to be minimum of 950mm wide designed to give a clear dimension from face of open door leaf to opposite door jam of 800mm - Building Regulations Part M Compliance. New accessable toilet door must be 1000mm overall set Other customer/staff toilets entrance door sets to be a minimum of 950mm wide overall. FD30 S VP SC -30min fire door construction (FD30) with intumescent seals including smoke stops (S) with Vision panels (VP and door closure (SC). FD60 doors to be used where stated. Vision panels in fire doors to be constructed in pyrobel 12 or swiss flam clear glazing to give 30min protection. Vision panels to be approx 1450mm x 150mm wide extending to within 300mm of door top and 300mm of door bottom and inset by 225mm from open side. Doors to kitchen to have high level vision panels with 500mm stainless steel kickplates to base and double sing hinge. Door leading from public spaces to back of house to be fitted with electronic access kepypad. All fire doors to have self closure devices with 'fire door kept shut' signs fitted to both sides. All fire doors not fitted with self closure devices to be fitted with 'FIRE DOOR KEEP SHUT' signage. Self closures must be designed to suit door weight and size, but set to an opening strength no greater than 20n. IRONMONGERY Door furniture, handles, kick plates/push plates all to be stainless steel satin finish. See finishes for details. All doors to be decorated on site with 1 coat primer and 2 coats egshell paint PT03. Architrave PT03 Final fire exit doors to be fitted with emergency release escape ironmongery to PART B Building Regulations and BS 9999. Additional last man out easy release securing device may be fitted in compliance wuth BS 9999, providing that the use is factored into clients risk assesment.

GAS LEGEND

FIRE EXTINGUISHERS

GAS PIPE GAS PIPE UNDER FLOOR

LIGHTING COVES

• Fire fighting equipment positions are indicative and supplied by client, direct order contractor, including extinguishers, related fire action notices and action point notices. • Photo illuminescent signage and final emergency and directional signage to comply with BS 5499:1 2002. H&S (Safety signs and signals) regulations 1996. • Main contractor to provide and fix 20mm chamfered pattress securley to wall/parttion. Overall size 700mm x 450mm, painted to match walls.

Orange Lighting Cove (Above Expresso Counter) PT01 - 'DD' Orange - Dulux Ref: 78YR 39/593 Yellow Lighting Cove (Main Seating Area) PT13 - 'DD' Nasturism - Dulux Ref: 12YY 51/682 Sizes Varies (See RCP & Setting out for details) Purple Lighting Cove (Main Seating Area) PT14 - 'DD' Forward Fuchsia Dulux Ref: 50RR 13/343 Sizes Varies (See RCP & Setting out for details) PINK Lighting Cove (Main Seating Area) PT15 - 'DD' Feverish Pink Dulux Ref: 83RR 23/486 Sizes Varies (See RCP & Setting out for details)

ELECTRICAL GENERAL NOTES New recessed LED downlighters to main seating areas front of house. Where ther is a first floor this all applies. New recessed LED fixed and directional downlighters to be installed to the counter bulkhead and MF ceiling behind counter. Fixed downlighters are to be installed in the dropped bulkhead with directional behind counter. Lighting coves to have Surface mounter Neutral flexible LED lighting strips.

ELECTRICAL GENERAL NOTES EN1838 & BS 5266 (1999). All socket outlets to be RCD protected (Excuding till equipment Power sockets) at the distribution board. Fire Alarm system to be designed in accordance with British Standard 5839 Part 1 & installed by Approved Contractor All work to conform to current Landlords Fit-out requirements and design specification. Fire Exit signage Design & Installation must conform to British Standard 5499 part 4-2000. Any alterarions to the fire alarm system will be in accordnace with BS 5839 Part 1. All doors and counter flaps on escape rutes will be readily openable without the use of a key. New ceilings and wall finishes will be surface spread of flame rating of Class 0 to circulation routes, Class 1 elsewhere and Class 3 to small rooms. Unless otherwise stated, new walls to be constructed from 12.5mm British Gypsum plasterboard to both sides of 70mm Cormet 'C' stud with 12mm ply lining to enale fixtures and fittings to be fixed to. This wall is to provide a 30mins fire resistance.

Ceiling and bulkhead above counter to be MF with recessed LED dowlighters - Finish PT12 Navajo White. Lighting cove above coffee Orange PT01 formed on-site. BOH to have 600 x 600mm suspended ceiling grid white to newly formed back of house areas unless otherwise stated.

EMERGENCY LIGHTING NOTES • • • • • • • • • •

All emergency lighting to be designed & installed in accordance with BSEN1838 & BS5266(1999) All Socket outlets to be RCD protected (Excluding till equipment Power Sockets) at the distribution board. Fire Alarm system to be designed in accordance with British Standard 5839 Part 1 & Installed by Approved Contractor. All works to conform to current Landlords Fit-out requirements. Fire Exit Signage Design & installation must conform to British Standard 5499 part 4-2000. Ceiling to be installed on solid supports (not wire) to comply with British Standard 8290 Part 1. Any alterations to the fire alarm system will be in accordance with BS5839 Part 1. Any alterations to the emergency lighting system will be in accordance with BS5266 Part1. All doors/counter flaps on escape routes will be readily openable without the use of a key. New ceilings and wall finishes will be surface spread of flame rating of Class O to circulation routes, Class 1 elsewhere, and Class 3 to small rooms.

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor - Electrical Notes

Scale : 1 : 60

Status : Draft Design

Date :

Dwg No : C-1.1

03/31/21

Rev :

DESIGNLABS LONDON ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1

1

C-2.3

C-2.4

LIGHTING KEY 2 C-5.1

ARC LED - 3HR Non-Maintained Emergency Luminaire

2

2

E

Mini Lean LED DL Recessed 28w 2400 lumen Flood Downlight in Whitefrom Prolight Design. Main Seating Area Product Ref: Prolight L1&L2 E denotes emergency pack fitted

E

Mini Lean LED DL Recessed 28w 2400 E lumen Flood Downlight in White from Prolight Design. Main Seating Area Product Ref: Prolight L1&L2 E denotes emergency pack fitted

1

2

C-3.1

2

E E

Decorative Glass Pendant with Glass shade with LED lamp inside. Main Seating Area Product Ref: Siru Illuminazione GALAPAGOS GLASS PENDANT LIGHT (or Alternative product: Nordlux Lighting Alton Pendant - 23Smoked Glass-Lampsy with Black Holder Light Bulb: 1x E27 Edison Screw Vintage Look-Max 60w)

E 2

REF. REF.

REF.

2

FRZ

ZONE A LIGHTING AREA

E

1500mm Baton flourescent fitting with diffuser. BOH areas LG3 (LG7) compliant diffuser E denotes with 3hr maintained emergency pack fitted.

3

BackLighting to Decorative Carvings: Rear mounted Colour Changing Programable Flexible LED Strip. Lighting to all 4 Sides of Carving Design in Guest Seating Areas Product Ref:

C-3.1

4 C-3.1

Coffer Lights: Surface mounted Colour Changing Programable Flexible LED Strip. Lighting to Main Ceiling Seating Coffer Product Ref:

LIGHTING KEY

2 C-2.1

1 : 60 E GENARAL NOTE

ZONE B LIGHTING AREA

ZONE A, ZONE B, ZONE C, ZONE D & ZONE E LIGHTING'S CONTROL SHALL BE SWITCH A, SWITCH B, SWITCH C, SWITCH D & SWITCH E.

2 C-3.1

5 C-3.1

A B C D

1 C-5.1

E

Dropdown Ceilings in Orange

E

ZONE E LIGHTING AREA

E

E

E

ZONE C LIGHTING AREA

ZONE D LIGHTING AREA E

1 C-2.1

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

E

E

Ground Floor Lighting Plan

Scale : As indicated

Status : Draft Design

Date :

Dwg No : C-2.0

04/15/21

Rev :

DESIGNLABS LONDON 2 C-2.3

1

Ground Floor - Lighting RCP 1 : 30

ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1

2

1

C-2.3

C-2.3

C-2.4

2

1

C-5.1

C-5.1

4

2

C-3.1

C-3.1

Ground Floor Kitchen Level 0 -150

1

GF Section 01 1 : 30

2 C-5.1

1

2

1

C-2.3

C-2.3

C-2.4 4

2

C-3.1

C-3.1

Ground Floor Kitchen Level 0 -150

2

GF Section 02 1 : 30

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor- Lighting Sections

Scale : 1 : 30

Status : Draft Design

Date :

Dwg No : C-2.1

04/17/21

Rev :

DESIGNLABS LONDON ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1

2

C-2.1

C-2.1

Ground Floor Kitchen Level 0 -150

2

GF Section 11 1 : 30

2 C-2.1 3

5

C-3.1

C-3.1

Ground Floor Kitchen Level 0 -150

1 C-2.1

1

GF Section 10 1 : 30

Client : Ijas Hussain / Muhammad Irfan Project : 1538-1540 London Road,

Streatham, London, SW16 4EU Drawing : Ground Floor- Lighting

Sections Scale : 1 : 30

Status : Draft Design

Date : 04/17/21

Dwg No : C-2.3

Rev :

DESIGNLABS LONDON ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


2 C-2.1 3

5

C-3.1

C-3.1

Ground Floor 0 1

1

GF Section 12

C-2.1

Kitchen Level

1 : 30

-150

Client : Ijas Hussain / Muhammad Irfan Project : 1538-1540 London Road,

Streatham, London, SW16 4EU Drawing : Ground Floor- Lighting

Sections Scale : 1 : 30

Status : Draft Design

Date : 04/17/21

Dwg No : C-2.4

Rev :

DESIGNLABS LONDON ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


EMERGENCY LIGHTING NOTES

RCP & LIFE SAFETY NOTES •

All new internal corridor and room door sets are to be minimum of 950mm wide designed to give a clear dimension from face of open door leaf to opposite door jam of 800mm - Building Regulations Part M Compliance. • New accessable toilet door must be 1000mm overall set Other customer/staff toilets entrance door sets to be a minimum of 950mm wide overall. • FD30 S VP SC -30min fire door construction (FD30) with intumescent seals including smoke stops (S) with Vision panels (VP and door closure (SC). FD60 doors to be used where stated. • Vision panels in fire doors to be constructed in pyrobel 12 or swiss flam clear glazing to give 30min protection. Vision panels to be approx 1450mm x 150mm wide extending to within 300mm of door top and 300mm of door bottom and inset by 225mm from open side. • Doors to kitchen to have high level vision panels with 500mm stainless steel kickplates to base and double sing hinge. • Door leading from public spaces to back of house to be fitted with electronic access kepypad. • All fire doors to have self closure devices with 'fire door kept shut' signs fitted to both sides. • All fire doors not fitted with self closure devices to be fitted with 'FIRE DOOR KEEP SHUT' signage. • Self closures must be designed to suit door weight and size, but set to an opening strength no greater than 20n. • IRONMONGERY: Door furniture, handles, kick plates/push plates all to be stainless steel satin finish. See finishes for details. • Door Finishes: All doors to be decorated on site with 1 coat primer and 2 coats egshell paint PT03. Architrave PT03 Final fire exit doors to be fitted with emergency release escape ironmongery to PART B Building Regulations and BS 9999. Additional last man out easy release securing device may be fitted in compliance wuth BS 9999, providing that the use is factored into clients risk assesment.

• • • • • • • • •

EMERGENCY LIGHTING NOTES 1 : 60

ELECTRICAL NOTES Main contractor to coordinate installations by suppliers below. 1. MUSIC SYSTEM: Client order direct supplier The base control unit for this system will be installed in the BOH and will require power. This system must also be linked to fire alarm system - to cut out upon activation of alarm. 2. FOOTFALL COUNTER: Check with client. Cable conduit by main contractor to service desk, M&E contractor to fit electric spur above door. All footfall kit to be concealed, or BOH. 3. CCTV: By Client Cabling and Data By Main Contractor positions TBC 4. INTRUDER ALARM: Client Nominated supplier M&E contractor to provide power and spurs as required in both front and back of house. Equipment locations to be agreed. Main contractor and fire detection contractor to liase with nominated supplier with reference to installations and sensitivity of systems relative to other fittings. 5. IT EQUIPMENT: Direct Order 6. BT INSTALLATION: Direct order supplier 7. HEARING LOOP INSTALLATION: Not applicable.

RCP & LIFE SAFETY NOTES 1 : 60

LIGHTING KEY

SPECIALIST INSTALLATION

ARC LED - 3HR Non-Maintained Emergency Luminaire

E

All emergency lighting to be designed & installed in accordance with BSEN1838 & BS5266(1999) All Socket outlets to be RCD protected (Excluding till equipment Power Sockets) at the distribution board. Fire Alarm system to be designed in accordance with British Standard 5839 Part 1 & Installed by Approved Contractor. All works to conform to current Landlords Fit-out requirements. Fire Exit Signage Design & installation must conform to British Standard 5499 part 4-2000. Ceiling to be installed on solid supports (not wire) to comply with British Standard 8290 Part 1. Any alterations to the fire alarm system will be in accordance with BS5839 Part 1. Any alterations to the emergency lighting system will be in accordance with BS5266 Part1. All doors/counter flaps on escape routes will be readily openable without the use of a key. New ceilings and wall finishes will be surface spread of flame rating of Class O to circulation routes, Class 1 elsewhere, and Class 3 to small rooms.

1 : 60

Mini Lean LED DL Recessed 28w 2400 lumen Flood Downlight in Whitefrom Prolight Design. Main Seating Area Product Ref: Prolight L1&L2 E denotes emergency pack fitted Mini Lean LED DL Recessed 28w 2400 E lumen Flood Downlight in White from Prolight Design. Main Seating Area Product Ref: Prolight L1&L2 E denotes emergency pack fitted Decorative Glass Pendant with Glass shade with LED lamp inside. Main Seating Area Product Ref: Siru Illuminazione GALAPAGOS GLASS PENDANT LIGHT (or Alternative product: Nordlux Lighting Alton Pendant - 23Smoked Glass-Lampsy with Black Holder Light Bulb: 1x E27 Edison Screw Vintage Look-Max 60w)

E

Image of Downlight

1500mm Baton flourescent fitting with diffuser. BOH areas LG3 (LG7) compliant diffuser E denotes with 3hr maintained emergency pack fitted. BackLighting to Decorative Carvings: Rear mounted Colour Changing Programable Flexible LED Strip. Lighting to all 4 Sides of Carving Design in Guest Seating Areas Product Ref: Coffer Lights: Surface mounted Colour Changing Programable Flexible LED Strip. Lighting to Main Ceiling Seating Coffer Product Ref:

LIGHTING KEY 1 : 60

Bulkhead and Lighting Cove Detail (to follow) Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor- Lighting Notes & Details

Scale : 1 : 60

Status : Draft Design

Date :

Dwg No : C-2.5

04/16/21

Rev :

DESIGNLABS LONDON ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1

1

C-2.3

C-2.4

Fire Exit

2

AE

Fire Exit

C-5.1

100 mmø

PLUMBING NOTES FE

Toilet connected to landlords fittings with 110mm waste with p trap and rodding eye at base. wash hand basin connected to landlords fittings with 38mm waste with p trap. low level wash hand basin connected to landlords fittings with 50mm waste with anti syphonic trap. All waste falls min 1:40

HL HL

40 mmø

Office/CCTV room

Changing Room

LOW LVL

LOW LVL

Staff WC

4x Pot Burners

LOW LVL

4x Hob Burners

LOW LVL 1

C-2.3 Ration Racks/ Ration Racks/ Store Store

Dry Store

LOW LVL

Drinks Store

LOW LVL

REF.

?

LOW LVL

REF.

Passage

Fire Door with Vision Panel

GAS PIPE UNDER FLOOR

100 mmø LOW LVL

FRZ LOW LVL

LOW LVL

Cutting Table with waste basket below

40 mmø

LOW LVL

40 mmø

Deep Bowl Washing Sink

Freezer

3 m²

C-3.1

40 mmø

Drying Racks

25MM ⌀ GAS PIPE

C-3.1

HL

Seating for 10x

Hand Dryer

130

40 mmø 3

4

Seating for 10x

GAS LEGEND GAS PIPE

Fire Door with Vision Panel

Food Washing

LOW LVL

Cutlery Racks

DRAINAGE UNDER FLOOR

Hand Wash

Ration Racks/ Ration Racks/ Store Store Store

DRAINAGE PIPE

Prep Table

Kitchen

REF.

Drinks Store

Utensils and Appliance storage

DRAINAGE LEGEND Fruit and Veg Racks

C-3.1 2

Utensils and Appliance storage

Fruit and Veg Racks

Guest WC

100 mmø

Corridor

Guest Hand Wash Store 2 C-2.1

40 mmø

Guest WC 40 mmø 2

LOW LVL

C-3.1

Hand Dryer Door with Vision Panel

5 C-3.1 LOW LVL

1

Cash Register

LOW LVL

HIGH LEVEL

C-5.1

HIGH LEVEL

Juice Bar

LOW LVL LOW LVL

Prep table Hand washing sink

4x 20 Seating

LOW LVL

Deep Bowl Washing Sink

4x Hobs

Grill with 4x hobs

1

Prep table

C-2.1

Display unit LOW LVL

Tandoor Client : Ijas Hussain / Muhammad Irfan Project :

Display unit

Fire Exit

T

Ground Floor - Drainage 1 Plan 1 : 30

Tandoor Drawing : Ground Floor - Drainage Plan

LOW LVL

LOW LVL

1 PL-DR-PR-RL-13

1538-1540 London Road, Streatham, London, SW16 4EU

Prep table

Scale : As indicated

Status : Draft Design

Date :

Dwg No : C-3.0

04/01/21

Rev :

DESIGNLABS LONDON ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com

Existing THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or Entrance to©reproduced be or construct without their prior written consent. All dimensions are to be checked on site by client or prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to Blocked contractor the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


Changing Room

Staff WC

Guest WC

Guest WC

Kitchen

Kitchen Handwash

Handwash Basin

Dishwashing Sink WC

40 mmø

WC

WC

Ground Floor Kitchen Level 0

Ground Floor Kitchen Level 0

-150

-150

100 mmø

100 mmø

100 mmø

Ground Floor Kitchen Level 0 -150

40 mmø 40 mmø

1

DRAINAGE SECTION 1

2

1 : 30

DRAINAGE SECTION 2 1 : 30

3

40 mmø

DRAINAGE SECTION 3 1 : 30

Kitchen

Ground Floor Kitchen Level 0

Ground Floor Kitchen Level 0

-150

4

DRAINAGE SECTION 4 1 : 30

32 mmø

5

-150

GAS SECTION 1 1 : 30

loor nd F u o r G v el n Le e h c t Ki 0 -150

6

DRAINAGE 3D 1 DRAINAGE LEGEND DRAINAGE PIPE DRAINAGE UNDER FLOOR

GAS LEGEND GAS PIPE GAS PIPE UNDER FLOOR

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor - Drainage & Gas Line 3D

Scale : As indicated

Status : Draft Design

Date :

Dwg No : C-3.1

04/14/21

Rev :

DESIGNLABS LONDON

7

DRAINAGE 3D 2

ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


NOTES: Refer to Architect's Flat Type Services Layout drawings xxx series for fire detection within flats.

Drawing to be read in conjunction with latest M&E drawings for fire detection and alarm systems.

Fire Exit

Fire Exit

AE

Room Area Designation:

Fire Strategy - Protected corridor/stairway (Communal)

FE

Smoke vent shaft with automated opening louvres connected to smoke alarm system serving this floor Apartment exit route protected by sprinkler supression system

FIRE EXIT FIRE EXIT

Partition Ratings:

PE

Office/CCTV room Changing Room

SD SD

Staff WC

4x Pot Burners

SD

4x Hob Burners

Fire Door Ratings:

30 Minutes Fire Rated Construction

FD30

Fire Rated Doors - 30 mins.

60 Minutes Fire Rated Construction

FD60

Fire Rated Doors - 60 mins.

90 Minutes Fire Rated Construction

S

120 Minutes Fire Rated Construction 240 Minutes Fire Rated Construction

Fire Exit Direction signage: All signs to conform with BS 5499 Part 1

P

FIRE EXIT

5

SD

FIRE EXIT

FIRE EXIT

FIRE EXIT

SD

Fire Rated Doors with intumescent smoke seals

SC

Fire Rated Doors with self closing device

Fire Door signage: All signs to conform with BS 5499 Part 1

FIRE EXIT

KS

Provide 'Fire Door - Keep Shut' signage

FIRE EXIT

KL

Provide 'Fire Door - Keep Locked' signage

EE

Emergency Egress window provided for means of escape. Minimum clear opening to be 0.33sqm (450(w) x 450(h)mm) and cill/transom height no greater than 1100.

FIRE EXIT

FIRE EXIT

Fire Cavity Barrier:

Dry Store

Kitchen

30 minute Fire Cavity Barriers installed vertically within the external wall cavity providing 30 minute integrity & 15 minute insulation. Refer to NBS Specification.

Passage

HD

SD

FIRE EXIT

FD60 SC

Fire Door with Vision Panel FD60 SC

P

REF.

Store

For Postion of Fire Cavity Barrier Refer to Setting Out Plans & Elevations: - For Ground Floor Cavity Barriers Refer to drawings CHU-CA-A-DR-GF-2030 to 2032 - For First Floor Cavity Barriers Refer to drawings CHU-CA-A-DR-01-2033 to 2035 - For First Floor Cavity Barriers Refer to drawings CHU-CA-A-DR-02-2036 to 2038 - For Position of Cavity Barriers in Elevations Refer to drawings CHU-CA-A-DR-XX-3030 to 3039 Masonry Cavity Walls- Fire Stopping will be provided horizontally at compartment floor locations fixed back to RC slab edge. All services passing through 30 minute & 60 minute compartment floors/ ceilings & walls including protected fire escape routes to have the appropriate fire collar, damper, pillows, sealant etc. fitted around them to the same fire resistance as the floor/ ceiling or wall it is passing through. Refer to NBS Specification.

5

All vertical & horizontal cavity barriers to rainscreen cladded external walls to be vented intumescent cavity barrier. 30min. cavity closers to be used around all window, screen & doors set in all external wall constructions. FIRE EXIT

REF.

REF.

FRZ

FIRE FIRE EXIT EXIT

? Fire Symbology:

Freezer

SD

130

Emergency Egress Travel Distance (Escape Route)

3 m² P

5

C

FD60 SC

5

PE

SD

FAP FARP DRI

Guest WC SD

SD

Corridor Guest Hand Wash

P

Dry Riser pipe overhead

DRO

5

Store

Push to exit button

HD

Heat Detector with built in Sounder & Flashing Beacon

SD

Smoke Detector with built in Sounder & Flashing Beacon

Manual Call Point (Break Glass)

HD

Heat Detector

Fire Alarm Master Panel

SD

Smoke Detector

Fire Alarm Remote Panel

HD

Heat Detector with built in Sounder

FE

Final Exit

Dry Riser Inlet

SD

Smoke Detector with built in Sounder

SE

Storey Exit

Additional Sounder

AE

Alternative Exit

Dry Riser Outlet

AV

Roof Light Automatic Venting

C

MV

Roof Light Manual Venting

F

AV

Roof Ventilator Automatic Venting

P

MV

Roof Ventilator Manual Venting

W

SD

Guest WC

FD60 SC

FAP

Opening with actuator to provide 1.5m2 clear area

Sprinkler Suppression

Fire Strategy - Extended Fire Symbols:

SD

FIRE EXIT

Door with Vision Panel

ATN

5 6 5 6

Fire Extinguisher Co2 - 5Kgs Fire Extinguisher Foam - 6L Fire Extinguisher Powder - 5Kgs Fire Extinguisher Water - 6L

!

A

Hazard A Description of Hazard

!

B

Hazard B Description of Hazard

B

Fire Blanket

Hose Reel

6060m length

FIRE EXIT

Cash Register

Juice Bar SD

SD

FIRE EXIT

SD

HD

Deep Bowl Washing Sink SD

SD

SD

4x Hobs FIRE EXIT

FIRE EXIT

Grill with 4x hobs

Display unit

HD SD

SD

SD

Tandoor

PE

P

Display unit

5

AE

FE

1

1

Ground Floor - Fire Strategy 1 : 30

PL-DR-PR-RL-13

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Prep table

FIRE EXIT

Ijas Hussain / Muhammad Irfan

Tandoor

Fire Exit FIRE EXIT

Client :

Ground Floor - Fire Strategy

Scale : As indicated

Status : Draft Design

Date :

Dwg No : C-4.0

04/02/21

Rev :

DESIGNLABS LONDON ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com

Existing Entrance to be © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or Blocked contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


FIRE EXTINGUISHERS

NOTES: Refer to Architect's Flat Type Services Layout drawings xxx series for fire detection within flats.

Drawing to be read in conjunction with latest M&E drawings for fire detection and alarm systems.

• Fire fighting equipment positions are indicative and supplied by client, direct order contractor, including extinguishers, related fire action notices and action point notices. • Photo illuminescent signage and final emergency and directional signage to comply with BS 5499:1 2002. H&S (Safety signs and signals) regulations 1996. • Main contractor to provide and fix 20mm chamfered pattress securley to wall/parttion. Overall size 700mm x 450mm, painted to match walls.

Room Area Designation:

Fire Strategy - Protected corridor/stairway (Communal) Smoke vent shaft with automated opening louvres connected to smoke alarm system serving this floor Apartment exit route protected by sprinkler supression system

Partition Ratings:

Fire Door Ratings:

30 Minutes Fire Rated Construction

FD30

Fire Rated Doors - 30 mins.

60 Minutes Fire Rated Construction

FD60

Fire Rated Doors - 60 mins.

FIRE EXTINGUISHERS

90 Minutes Fire Rated Construction

S

Fire Rated Doors with intumescent smoke seals

1 : 60

120 Minutes Fire Rated Construction 240 Minutes Fire Rated Construction

Fire Exit Direction signage: All signs to conform with BS 5499 Part 1 FIRE EXIT

FIRE EXIT

FIRE EXIT

SC

Fire Rated Doors with self closing device

RCP & LIFE SAFETY NOTES

Fire Door signage: All signs to conform with BS 5499 Part 1

FIRE EXIT

KS

Provide 'Fire Door - Keep Shut' signage

FIRE EXIT

KL

Provide 'Fire Door - Keep Locked' signage

EE

Emergency Egress window provided for means of escape. Minimum clear opening to be 0.33sqm (450(w) x 450(h)mm) and cill/transom height no greater than 1100.

FIRE EXIT

All new internal corridor and room door sets are to be minimum of 950mm wide designed to give a clear dimension from face of open door leaf to opposite door jam of 800mm - Building Regulations Part M Compliance. • New accessable toilet door must be 1000mm overall set Other customer/staff toilets entrance door sets to be a minimum of 950mm wide overall. • FD30 S VP SC -30min fire door construction (FD30) with intumescent seals including smoke stops (S) with Vision panels (VP and door closure (SC). FD60 doors to be used where stated. • Vision panels in fire doors to be constructed in pyrobel 12 or swiss flam clear glazing to give 30min protection. Vision panels to be approx 1450mm x 150mm wide extending to within 300mm of door top and 300mm of door bottom and inset by 225mm from open side. • Doors to kitchen to have high level vision panels with 500mm stainless steel kickplates to base and double sing hinge. • Door leading from public spaces to back of house to be fitted with electronic access kepypad. • All fire doors to have self closure devices with 'fire door kept shut' signs fitted to both sides. • All fire doors not fitted with self closure devices to be fitted with 'FIRE DOOR KEEP SHUT' signage. • Self closures must be designed to suit door weight and size, but set to an opening strength no greater than 20n. • IRONMONGERY: Door furniture, handles, kick plates/push plates all to be stainless steel satin finish. See finishes for details. • Door Finishes: All doors to be decorated on site with 1 coat primer and 2 coats egshell paint PT03. Architrave PT03 Final fire exit doors to be fitted with emergency release escape ironmongery to PART B Building Regulations and BS 9999. Additional last man out easy release securing device may be fitted in compliance wuth BS 9999, providing that the use is factored into clients risk assesment.

Fire Cavity Barrier: 30 minute Fire Cavity Barriers installed vertically within the external wall cavity providing 30 minute integrity & 15 minute insulation. Refer to NBS Specification. For Postion of Fire Cavity Barrier Refer to Setting Out Plans & Elevations: - For Ground Floor Cavity Barriers Refer to drawings CHU-CA-A-DR-GF-2030 to 2032 - For First Floor Cavity Barriers Refer to drawings CHU-CA-A-DR-01-2033 to 2035 - For First Floor Cavity Barriers Refer to drawings CHU-CA-A-DR-02-2036 to 2038 - For Position of Cavity Barriers in Elevations Refer to drawings CHU-CA-A-DR-XX-3030 to 3039

Masonry Cavity Walls- Fire Stopping will be provided horizontally at compartment floor locations fixed back to RC slab edge. All services passing through 30 minute & 60 minute compartment floors/ ceilings & walls including protected fire escape routes to have the appropriate fire collar, damper, pillows, sealant etc. fitted around them to the same fire resistance as the floor/ ceiling or wall it is passing through. Refer to NBS Specification. All vertical & horizontal cavity barriers to rainscreen cladded external walls to be vented intumescent cavity barrier. 30min. cavity closers to be used around all window, screen & doors set in all external wall constructions.

Fire Symbology:

Emergency Egress

Dry Riser pipe overhead

Travel Distance (Escape Route) PE

FAP FARP DRI DRO

ATN

Opening with actuator to provide 1.5m2 clear area

Push to exit button

HD

Heat Detector with built in Sounder & Flashing Beacon

SD

Smoke Detector with built in Sounder & Flashing Beacon

Manual Call Point (Break Glass)

HD

Heat Detector

Fire Alarm Master Panel

SD

Smoke Detector

Fire Alarm Remote Panel

HD

Heat Detector with built in Sounder

FE

Final Exit

Dry Riser Inlet

SD

Smoke Detector with built in Sounder

SE

Storey Exit

Additional Sounder

AE

Alternative Exit

Dry Riser Outlet

Sprinkler Suppression

RCP & LIFE SAFETY NOTES

Fire Strategy - Extended Fire Symbols:

AV

Roof Light Automatic Venting

C

MV

Roof Light Manual Venting

F

AV

Roof Ventilator Automatic Venting

P

MV

Roof Ventilator Manual Venting

W

5 6 5 6

Fire Extinguisher Co2 - 5Kgs Fire Extinguisher Foam - 6L Fire Extinguisher Powder - 5Kgs Fire Extinguisher Water - 6L

!

A

Hazard A Description of Hazard

!

B

Hazard B Description of Hazard

B

1 : 60

Fire Blanket

EMERGENCY LIGHTING NOTES

Hose Reel

6060m length

• •

FIRE STRATEGY NOTES 1:1

• • • • • • • •

All emergency lighting to be designed & installed in accordance with BSEN1838 & BS5266(1999) All Socket outlets to be RCD protected (Excluding till equipment Power Sockets) at the distribution board. Fire Alarm system to be designed in accordance with British Standard 5839 Part 1 & Installed by Approved Contractor. All works to conform to current Landlords Fit-out requirements. Fire Exit Signage Design & installation must conform to British Standard 5499 part 4-2000. Ceiling to be installed on solid supports (not wire) to comply with British Standard 8290 Part 1. Any alterations to the fire alarm system will be in accordance with BS5839 Part 1. Any alterations to the emergency lighting system will be in accordance with BS5266 Part1. All doors/counter flaps on escape routes will be readily openable without the use of a key. New ceilings and wall finishes will be surface spread of flame rating of Class O to circulation routes, Class 1 elsewhere, and Class 3 to small rooms.

EMERGENCY LIGHTING NOTES 1 : 60

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground FLoor Fire Strategy Notes

Scale : As indicated

Status : Draft Design

Date :

Dwg No : C-4.1

04/02/21

Rev :

DESIGNLABS LONDON ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


Fire Exit

2

AE

Fire Exit

C-5.1

FE

HL HL

LOW LVL

LOW LVL

4x Hob Burners

4x Pot Burners

LOW LVL

Fruit and Veg Racks

LOW LVL

FAN Ration Racks/ Ration Racks/ Store Store

Prep Table

Utensils and Appliance storage

Hand Wash

Ration Racks/ Ration Racks/ Store Store LOW LVL

Drinks Store

REF.

Cutlery Racks

LOW LVL

LOW LVL

REF.

Fire Door with Vision Panel

Food Washing

LOW LVL

REF.

Drinks Store

Utensils and Appliance storage

Fruit and Veg Racks

Fire Door with Vision Panel

LOW LVL

FRZ LOW LVL

LOW LVL

Cutting Table with waste basket below

LOW LVL

Deep Bowl Washing Sink Drying Racks

HL

Seating for 10x

HL

Seating for 10x

Hand Dryer

LOW LVL HL

Hand Dryer

Door with Vision Panel LOW LVL

400 mmø 1

Cash Register

LOW LVL

HIGH LEVEL

C-5.1

HIGH LEVEL

Juice Bar

LOW LVL LOW LVL

Prep table Hand washing sink

4x 20 Seating

LOW LVL

Deep Bowl Washing Sink

WI-FI

4x Hobs

Grill with 4x hobs

Prep table

Display unit LOW LVL

Tandoor Client :

Ijas Hussain / Muhammad Irfan

1538-1540 London Road, Streatham, London, SW16 4EU Tandoor

Project :

Display unit

Drawing :

Fire Exit

LOW LVL

LOW LVL

T

1

1

Duct Plan 1 : 30

Ground Floor - Duct Plan

PL-DR-PR-RL-13

Scale : 1 : 30

Status : Draft Design

Date :

Dwg No : C-5.0

04/17/21

Rev :

Prep table

DESIGNLABS LONDON ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING Existing T: 07870661614 / 07888831314 Entrance to be E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or Blocked reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


First Floor

3123

3650

Ground Floor Kitchen Level 0 -150

DUCT SECTION 1

1

1 : 30

First Floor 3650

400 mmø

400 mmø

3123

2770

400 mmø

Ground Floor Kitchen Level 0 -150

2

DUCT SECTION 2 1 : 30

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Duct Section and 3d

Scale : 1 : 30

Status : Draft Design

Date :

Dwg No : C-5.1

04/17/21

Rev :

DESIGNLABS LONDON

3

Duct 3D

ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


1

1

C-2.3

C-2.4

2 C-5.1

1 C-3.1

demolish existing column and beam 3 C-3.1 1 C-ST-DR-PR-00-02 4

E U xis K ti C ng 15 2x 15 2

x5 1 E U xis K ti C ng 15 2x 15 2

x5 1

2 C-2.1

E U xis K ti C ng 15 2x 15 2x Ex 51 U is K ti C ng 15 2x 15 2x 51

C-3.1

2 C-3.1

5 C-3.1

Existing / UKC152x152x51

Existing / UKC152x152x51

1 C-5.1

8

C U 1 K C 25

4x 2

54

x7 3

4

B1.02 / UKC254x254x73

NOTE: 254UC73 size beam will not require steel plate on top. (minimum beam size of 203UC71 will require a plate)

3

C U 1 K C 25

this size beam will not require steel plate on top. (minimum beam size of 203UC71 will require a plate)

4x 2

54

x7 3

demolish existing wall

C U 1 K C 25

4x 2

54

x7 3

2

1

B1.01 / UKC254x254x73

C-2.1

1

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

C U 1 K C 25

4x 2

54

x7 3

demolish existing wall

Drawing :

Ground Floor Structural Plan

Scale : 1 : 30

Status : Draft Design

Date :

Dwg No : C-ST-DR-PR-00-01

03/30/21

Rev :

DESIGNLABS LONDON 2 C-2.3

5

1

Structure Ground Floor- RCP 1 : 30

6

7

ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


4

3

2

1

4x 2 C U 1 K C 25

4x 2

54

x7 3

B1.01 / UKC254x254x73

C U 1 K C 25

C U 1 K C 25

4x 2

54

x7 3

B1.02 / UKC254x254x73

C U 1 K C 25

4x 2

54

54

x7 3

x7 3

8

/ UKC254x254x73

/ UKC254x254x73

Ground Floor 0

1

Kitchen Level

Section 23

-150

1 : 30

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Section & Images

Scale : 1 : 30

Status : Draft Design

Date :

Dwg No : C-ST-DR-PR-00-02

03/30/21

Rev :

DESIGNLABS LONDON ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


AA Section 03

1

1 : 25

0.5

0

SCALE 1: 50

0.5

1

1.5

2

2.5 m

3 ID-DR-OP1-00-106

AA Section 04

2

1 : 25

Client : Ijas Hussain / Muhammad Irfan Project : 1538-1540 London Road,

Streatham, London, SW16 4EU Drawing : Ground Floor Design Option

1 in 3D- Sections Scale : 1 : 25 Date : 05/07/21

Status : Draft Design

Rev :

Dwg No : ID-DR-OP1-00-100

D E S I G N L A B S L O N D O N

3

AA Section 05 1 : 25

ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


Client Issued Chair

Client Issued Chair & Table

Enea-Kaiak Chair or similar design

White FR LED Down-light

Nora Lone Front Carousel_1080x Dining Table or similar design

Pendants: Nordlux Alton 23 Smoked-glass-pendant light_2048x. Location- Main Guest Seating Areas.

Pendants: Norah Bathroom Pendant, Warm Grey & Brushed Brass. Location- Bathroom.

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Ground Floor Design Option 1- Furniture Specs

Scale : Date :

Status : Draft Design 05/07/21

Rev :

Dwg No : ID-DR-OP1-00-101

D E S I G N L A B S L O N D O N

Pendants: Corben Bathroom Pendant Light, Frosted Glass. Location- Bathroom & Main Guest Seating Areas.

ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


Metallic Finish Mirror

Blue Green Tiles

Brass or Gold finish spouts Over counter composite stone guest sink Timber or Stone Counter Top

DWELL-AZUL GLAZED TILE FROM PORCELAIN SUPERSTORE HTTPS://WWW.PORCELAINSUPERSTO RE.CO.UK/PRODUCTS/

SINK SPEC: LUSSO PICASSO PEBBLE GREY STONE RESIN COUNTER TOP BASIN 580

TILES SPECS: OSKA-JUNGLEGREEN-MATT-PORCELAINHEXAGON-WITH-VIOLET-GROUTFROM MANDARIN STONE-£42 SQ M CROSS WATER MPRO BASIN 3 HOLE SPOUT SET

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Bathroom Design Concepts

Scale :

OPTIONAL SINK SPEC: LUSSO OASIS PEBBLE GREY ROUND STONE RESIN COUNTER TOP BASIN 420

Date :

Status : Draft Design 05/07/21

Rev :

Dwg No : ID-DR-OP1-00-102

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


VINTAGE HANGING LIGHTS

ALANA ROUND MIRROR-50CM BRUSHED BRASS

CORA LARGE WALL HANGING MIRROR BLACK & GOLD

VINTAGE LIGHTING

CROSSWATER MPRO BASIN 3 HOLE SPOUT SET BRUSHED BRASS FINISH

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Bathroom Design Concepts

Scale : Date :

Status : Draft Design 05/12/21

Rev :

Dwg No : ID-DR-OP1-00-103

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


3020

599

599

1676

CNC Cut MDF Panel- Type 1 Location: High Level Pelmut Finish: Brass Metallic Matt Finish Backing: Antique Mirror Quantity: 19 nos.

CNC Cut MDF Panel- Type 2 Location: Cash Desk, Serving Counter Finish: Brass Metallic Matt Finish Backing: Backlighting to Frosted white perspecs Quantity: 3nos

1962

868

868

AC/FCU slots in the ceiling hidden behind the CNC Panel

CNC Cut MDF Panel- Type 3 1 : 10

3035

2813

AC/FCU hidden in the ceiling behind the CNC Panel 2813

3

CNC Cut MDF Panel- Type 3 Location: Main Guest Seating Walls Finish: Brass Metallic Matt Finish Backing: Back illuminated milky white perpecs Quantity: 6 nos.

Ceiling CNC Panel Type 5

2

1 : 10

CNC Cut MDF Panel- Type 5 Location: Main Guest Seating Ceiling Finish: Brass Metallic Matt Finish Backing: none/open Quantity: 3 nos. Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

1

Ceiling CNC Panel Type 4 1 : 10

CNC Cut MDF Panel- Type4 Location: Main Guest Seating Ceiling Finish: Brass Metallic Matt Finish Backing: No backing/Open for FCU Air Led lights at edging Quantity: 2 nos.

CNC Panels

Scale : 1 : 10

Status : Draft Design

Date :

Dwg No : ID-DR-OP1-00-106

05/10/21

Rev :

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


WORK IN PROGRESS: CONCEPT IN BROWN FLOOR, NO COFFER LIGHTING BROWN TABLE AND BROWN PAINTED CHAIR WITH MATCHING FABRIC AND WHITE PANELS. WALLS IN POLISH PLASTER.

WORK IN PROGRESS: CONCEPT IN BROWN FLOOR, NO COFFER LIGHTING BROWN TABLE AND BROWN PAINTED CHAIR WITH MATCHING FABRIC AND WHITE CARVED-DESIGN PANELS. WALLS IN POLISH PLASTER.

WORK IN PROGRES: CONCEPT IN TIMBER FLOOR, COFFER LIGHTING BROWN TABLE AND TIMBER CHAIR WITH BLUE FABRIC AND GOLDEN CARVED-DESIGN PANELS. WALLS IN POLISH PLASTER.

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Renders

Scale : Date :

Status : Draft Design 05/09/21

Rev :

Dwg No : ID-DR-OP1-00-120

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


WORK IN PROGRESS: CONCEPT IN TIMBER FLOOR, COFFER LIGHTING BROWN TABLE AND TIMBER CHAIR WITH BLUE FABRIC AND GOLDEN, WHITE AND COPPER CARVED-DESIGN PANELS. WALLS IN POLISH PLASTER.

WORK IN PROGRESS: CONCEPT OF THE CASHIER COUNTER IN BLACK MARBLE, DARK TIMBER FLOOR, COFFER LIGHTING AND GOLDEN CARVEDDESIGN PANELS. NOTE THAT CASHIER COUNTER'S CARVED PANELS DOES NOT HAVE BACK LIGHTING

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Renders

Scale : Date :

Status : Draft Design 05/10/21

Rev :

Dwg No : ID-DR-OP1-00-121

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


WORK IN PROGRESS: CONCEPT IN TIMBER FLOOR, COFFER LIGHTING GRAY TABLE AND TIMBER CHAIR WITH BLUE FABRIC AND GOLDEN, WHITE AND COPPER CARVED-DESIGN PANELS. WALLS IN POLISH PLASTER.

WORK IN PROGRESS: CONCEPT WITH CASH COUNTER PAINTED AND WITH NO CARVED PANEL, DARK TIMBER FLOOR, COFFER LIGHTING, BROWN TABLE AND TIMBER CHAIR WITH BLUE FABRIC AND GOLDEN, WHITE AND COPPER CARVED-DESIGN PANELS. WALLS IN POLISH PLASTER.

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Renders

Scale : Date :

Status : Draft Design 05/10/21

Rev :

Dwg No : ID-DR-OP1-00-122

D E S I G N L A B S L O N D O N WORK IN PROGRESS: CONCEPT WITH CASH COUNTER PAINTED WITH CARVED PANEL, DARK TIMBER FLOOR, COFFER LIGHTING, BROWN TABLE AND TIMBER CHAIR WITH BLUE FABRIC AND GOLDEN PAINTED CARVEDDESIGN PANELS WITH BLACK PAINTED WALLS

ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


WORK IN PROGRESS: DARK TIMBER FLOOR, COFFER LIGHTING, DARK BROWN TABLE AND TIMBER CHAIR WITH BLUE FABRIC AND GOLDEN, WHITE AND COPPER PANELS. WALLS IN BLACK MARBLE OR MARBLE LOOK LAMINATED PANELS.

WORK IN PROGRESS: DARK TIMBER FLOOR, COFFER LIGHTING, DARK BROWN TABLE AND TIMBER CHAIR WITH BLUE FABRIC AND GOLDEN PAINT CARVED-DESIGN PANELS. DARK PAINTED OR LAMINATED PANELS.

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Renders

Scale : Date :

Status : Draft Design 05/10/21

Rev :

Dwg No : ID-DR-OP1-00-123

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


FINAL RENDERS

FINAL RENDERS

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Renders

Scale : Date :

Status : Draft Design 05/10/21

Rev :

Dwg No : ID-DR-OP1-00-124

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


FINAL RENDERS

FINAL RENDERS

Client :

Ijas Hussain / Muhammad Irfan

Project :

1538-1540 London Road, Streatham, London, SW16 4EU

Drawing :

Renders

Scale : Date :

Status : Draft Design 05/12/21

Rev :

Dwg No : ID-DR-OP1-00-125

D E S I G N L A B S L O N D O N ARCHITECTURE / INTERIOR / MANAGEMENT / PLANNING T: 07870661614 / 07888831314 E: info@designlabslondon.com W: www.designlabslondon.com © THIS DRAWING IS THE COPYRIGHT OF DESIGNLABS LONDON LTD. It shall not be in any way used or reproduced or construct without their prior written consent. All dimensions are to be checked on site by client or contractor prior to commencing any work. Work only to figured dimensions. Any discrepancies are to be reported to the DLL in writing and DLL shall not take responsiblity for site failing to inform discrepancies.


Turn static files into dynamic content formats.