Our professional approach to business has led us to be members of, and participate in:

NUAIRE IS A WORLD LEADER IN THE DEVELOPMENT AND MANUFACTURE OF FANS AND VENTILATION SYSTEMS Established in 1967, the Nuaire name has been at the forefront of the industry worldwide for more than 40 years. • 1st ventilation manufacturer to achieve ISO 9001 • 1st ventilation manufacturer to achieve the Carbon Trust Standard in 2009 • 1st ventilation manufacturer to achieve the Queen’s Award for Innovation in 2004 • 1st ventilation manufacturer to have AMCA & BSI independently certified test laboratory

2

029 2085 8200


Modern ventilation is about people and providing a good level of indoor air quality whilst ensuring an effective building performance. Critical factors such as air quality, energy efficiency and noise pollution are always considered to ensure suitable product selection. Our aim is to provide you with an application guide specifically for Student

Accommodation, Care Homes & Hotels,

which assists with clarifying the regulations and selecting the most energy efficient ventilation system for your project

Mark Huxtable, Managing Director.

Contents With its roots in fans and mechanical ventilation products, Nuaire has progressively expanded its range and extended its capability to encompass technologies at all levels of ventilation solutions. Nuaire is the only company able to offer the complete ventilation solution for the built environment. Nuaire’s approach has always been to put people first. This value is embedded in its design philosophy and underpins its relationships with customers, colleagues and stakeholders. Nuaire is passionate about ventilation in the built environment, whilst responding to environmental issues, new opportunities and industrial changes. Nuaire has a reputation for developing ventilation solutions to satisfy the most challenging of building services applications anywhere in the world.

2-3

INTRODUCTION TO NUAIRE

4

MADE IN THE U. K.

5

FAN SELECTOR, BIM & REVIT

6-9

COMPLYING WITH BUILDING REGULATIONS

10 - 11

APPLICATION & PRODUCT SELECTOR

12 - 13

STUDENT ACCOMMODATION

14 - 15

CARE HOMES ACCOMMODATION

16 - 17

HOTEL ACCOMMODATION

18 - 23

WALL & CEILING MOUNTED UNITS

24 - 27

DUCTED IN CEILING VOID UNITS

28 - 31

PLANT ROOM & ROOF UNITS

33

STUDENT ACCOMMODATION PROJECTS

34

CARE HOME ACCOMMODATION PROJECTS

35

HOTEL ACCOMMODATION PROJECTS

nuaire.co.uk

3


Made in the UK

THANKS TO ITS ADVANCED MANUFACTURING TECHNOLOGY IN THE UK, NUAIRE CAN SUPPLY EXCELLENT ‘GOLD STAR’ QUALITY AND MEET THE MOST DEMANDING OF DELIVERY TIMES Nuaire implements the relevant industry standards which ensures that all its processes and components are certified. Nuaire was the first fan manufacturer in the world to achieve the quality standard ISO 9001, and its commitment to quality remains embedded in all aspects of its operations.

Our commitment - our people - your support Nuaire is renowned worldwide for its expertise, commitment to innovation and the outstanding quality of its products and customer service. People are at the heart of Nuaire, and the company has over 450 staff at its UK headquarters. In addition, Nuaire has technical sales engineers throughout Britain, as well as dedicated partners across the globe, including offices in Dubai, Oman, Qatar, Kuwait, Bahrain and Finland. Nuaire’s committed staff include leading experts who are constantly setting new standards for the industry by developing new, innovative products in the company’s research and development department – the largest and most advanced in the UK.

4

029 2085 8200

Business is growing annually and the company is on course to double in size within four to five years. The development of innovative new products is heavily responsible for this expected growth, which set the standards for energy efficiency and reduced carbon emissions.


WE UNDERSTAND THE MANY CHALLENGES AND REGULATIONS THAT MODERN BUILDING VENTILATION MUST MEET... AND OUR TECHNICAL TEAM ARE ON HAND TO ASSIST WITH PRODUCT SELECTIONS Building Information Modelling (BIM) is both a new technology and a new way of working. BIM is a term that has been around for a while in manufacturing and engineering industries, and is now beginning to make an impact in the construction sector. Nuaire has a dedicated BIM Team offering libraries of Revit® compatible BIM models to meet customers’ exact specification. Nuaire’s libraries offer collision detection through geometry, connection positions and weights. Project specific performance criteria and support for design, project management and building operations can be requested which will result in improved design efficiency. To download Nuaire’s Revit® compatible BIM models simply visit www.nuaire.co.uk/BIM and click on the library. Alternatively, simply email the team BIM@nuaire.co.uk with your request.

REVIT compatible BIM models

Nuaire’s fan selector was first launched 20 years ago and has an iconic reputation within the HVAC community. A practical and helpful tool to assist with the selection of ventilation products, the software provides detailed datasheets comprising efficiency, performance, acoustics, wiring and specification. The software allows all of the data to be imported in Microsoft or DXF format for AutoCAD. To download Fan Selector simply visit www.nuairegroup.com and follow the instructions. An email reminder will be sent to you each time Fan Selector has been updated, enabling you to download the latest copy. Alternatively, you can request a copy of Fan Selector on CD-ROM from the above website.

nuaire.co.uk

5


Complying with Building Regulations

COMPLYING WITH BUILDING REGULATIONS WHEN DESIGNING A VENTILATION STRATEGY FOR STUDENT ACCOMMODATION AND CARE HOMES By Colin Biggs (Nuaire Technical & Development Director) MSC.

New changes to Part L1A and B, and Part L2A and B come into effect from 6th April 2014.

Source: www.planningportal.gov.uk/approveddocuments. www.cibse knowledgeportal.co.uk/cibse-guides

As part of our continuous product development process, Nuaire recently carried out a survey of its customers to ascertain the design engineer’s views on the ventilation system design requirements for Student Accommodation (SA) and Care Homes (CH). It became apparent that there wasn’t a straight-forward answer, and in many cases engineers choose from a variety of guidance sources for flow rates, and also between AD (Approved Document) L1 A/B and AD L2 A/B (L1 – dwellings; L2 – non-dwellings; A – new buildings; B – existing buildings) for the energy assessment criteria on SA / CH buildings. Faced with this ambiguity, we decided to look at the guidance in more detail and the following should provide clarification and demonstrate how we interpret it.

ENERGY PERFORMANCE CRITERIA Approved documents L1A / B, L2A / B Conservation of Fuel and Power. Some of this is actually very straightforward. AD L1A (3.1 p7) defines a Dwelling as a “selfcontained unit designed to accommodate a single household”, and that “buildings exclusively containing rooms for residential purposes such as nursing homes, student accommodation and similar are not dwellings and in such cases Approved Document Part L2A applies”.

6

029 2085 8200

A live-work unit (AD L1A 3.3) is defined as a unit containing both living and a space for commercial purposes. “The whole unit should be treated as a dwelling as long as the commercial part could revert to domestic use”. Mixed use developments (AD L1A 3.4) where a dwelling exists in a larger building that contains other types of accommodation, ADL1A should be used for each individual dwelling. However, for the “non-dwelling” parts, including communal lounges, common rooms, retail or commercial spaces AD L2A applies.

An example of this application type would be “Extra-care” homes where each resident has their own self-contained accommodation, and communal spaces are provided for social activities.


Complying with Building Regulations

Typically all of these methods result in an overall ventilation rate of approximately 0.5 air changes per hour. Other criteria ensure that at least 0.3 l/s per m2 of floor area is provided, and that an additional 4 l/s per person are provided for occupancy levels above normal (two occupants per main bedroom and one in each of the other bedrooms).

VENTILATION CRITERIA Approved Document F and other guidance.

VENTILATION FOR DWELLINGS Approved Document F1 offers a great deal of guidance on dwelling ventilation methods and rates as shown in Tables 5.1a and 5.1b. The available methods are :System 1: Intermittent extract from wet rooms (i.e. kitchen, bathroom, utility room), and background ventilators (trickle vents).

Purge Ventilation: An additional requirement for purge ventilation at 4 ach for each habitable room is stipulated to “rapidly dilute pollutants and/or water vapour”. Since the purge requirement is by definition occasional and temporary, appropriately sized open-able windows or manually controlled local extract fans may satisfy this requirement. ADF Paragraph 4.15 states that “Purge ventilation provisions may also be used to improve thermal comfort, although this is not controlled under the Building Regulations”.

System 2: Extract from wet rooms using Passive Stacks. (Trickle vents required). System 3: Continuous extract (from wet rooms – either using a centralised unit (MEV - Mechanical Extract Ventilation), or several individual units dMEV – decentralised Mechanical Extract Ventilation). (Trickle vents required).

VENTILATION OF INDIVIDUAL STUDY / BEDROOMS

System 4: Continuous Mechanical supply and extract Ventilation with Heat Recovery (MVHR).

The guidance in ADF1 offers a starting point for the evaluation of the ventilation requirements for an individual study / bedroom. Where provided with an en-suite bathroom, this type of accommodation closely equates to a small single bedroom dwelling, and a continuous supply to bedroom / extract from bathroom rate of 13 l/s will satisfy all general

The table below shows continuous whole dwelling ventilation rates based primarily on the number of bedrooms, and extract rates that “at least” match these in normal operating mode, but with provision to boost to a higher rate on demand.

Table 5. 1a Extract ventilation rates Room

Intermittent extract

Continuous extract

Minimum rate

Minimum high rate

Kitchen

30 l/s adjacent to hob; or 60 l/s elsewhere

13 l/s

Utility room

30 l/s

8 l/s

Bathroom

15 l/s

8 l/s

Sanitary accommodation

6 l/s

6 l/s

Minimum low rate Total extract rate should be at least the whole dwelling ventilation rate given in table 5. 1b.

requirements (n.b. whilst floor area and occupancy must also be considered, the need for purge ventilation in individual rooms with no cooking or maintenance whilst occupied is debatable). Approved Document Part L2A covers work on new non-domestic buildings and major extensions to existing non-domestic buildings i.e where the additional useful floor area is greater than 100m2 and 25% of the original building’s floor area. Approved Document Part L2B addresses work on existing buildings including extensions (smaller than 100m2 and 25% of the original building’s floor area), change of building use, provision or extension of controlled services and fittings, replacement of thermal elements and consequential improvements. Approved Document Part L2A General Guidance states that a Room for residential purposes is a room, or a suite of rooms, which is not a dwellinghouse or a flat and which is used by one or more persons to live and sleep and includes a room in a hostel, a hotel, a boarding house, a hall of residence or a residential home, but does not include a room in a hospital, or other similar establishment, used for patient accommodation. Approved Document Part L is concerned mainly with assessment of energy performance. The methodology or calculation tool used for nondomestic buildings is SBEM (Simplified Building Energy Model). SBEM makes the following assumptions about air flow rates:- (see table below).

STUDENT ACCOMMODATION Bathroom (extract)

12l/s

Bedroom (supply)

10l/s

CARE HOME ACCOMMODATION

Table 5. 1b Whole dwelling ventilation rates

Bathroom (extract)

12l/s

Bedroom (supply)

10l/s

Number of bedrooms in dwelling

Whole dwelling ventilation rate a, b (l/s)

1

2

3

4

5

13

17

21

25

29

Notes: a. In addition, the minimum ventilation rate should be not less than 0.3 l/s per m2 of internal floor area. (This includes all floors, e.g. for a two-storey building add the ground and first floor areas.) b. This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as the default value. If a greater level of occupancy is expected add 4 l/s per occupant.

Consideration needs to be given to the comfort requirements of the building occupants. Care homes for example, require a continuously warm environment and students are not known for their ability to consistently control the ventilation within their rooms.

nuaire.co.uk

7


Complying with Building Regulations

Providing a mechanical centralised system would generally ensure that the healthiest environment is maintained. Manually opening a window would not be seen as the most effective method particularly for areas that have external pollution and noise. CIBSE Guide A (Environmental criteria for design). Table 1.10 recommends an outdoor air supply rate of 8 l/s per person for sedentary, occupants (e.g. in a Care Home). This outdoor air supply rate assumes that the outdoor air supplied to the space is fully mixed with the room air and should be adjusted if the ventilation effectiveness, (see CIBSE Guide A section 1.7.4), is expected to take a value other than 1.

Level of smoking

Part F 1 Table 6.3 Ventilation of other buildings and spaces states for Communal residential buildings to refer to CIBSE Guide B:2005, Section 2.3.8. and Good Practice Guide (GPG) 192 - Designing energy efficient multi-residential buildings. The latter document gives general information but was last published in 2003. CIBSE Guide B 2.3.8.1 - Communal residential properties - are defined as buildings containing separate residential units with some provision of communal facilities. The Guide considers residential care homes, student accommodation and military barracks and says that ‘as with domestic properties, effective ventilation is best provided by reducing air leakage, extracting moisture and pollutants at source, and providing occupant controllable ventilation’.

Proportion of occupants that smoke (%)

Outdoor air supply rate (l/s -1 person -1)

No smoking

0

8

Some smoking

25

16

Heavy smoking

45

24

Very heavy smoking

75

36

SMOKING IN CARE / RESIDENTIAL HOMES Our research has shown that it is typical for limited smoking provision to be made for residents (not staff) in this type of building. This being the case, the most relevant specification data available is offered in the Table 1.10 CIBSE Guide A. (see table above). Adoption of the outdoor air supply rates given will not guarantee that non-smokers present will not be exposed to harmful effects. Steps must also be taken to ensure that there is no transfer of smoke from areas in which smoking is permitted to other areas (for example constant pressure control to maintain a negative differential (see page 29). The outdoor air supply rates given in Table 1.10 assume that the outdoor air supplied to the space is fully mixed with the room air. These rates should be adjusted if the ventilation effectiveness, see section 1.7.4, is expected to take a value other than 1.0.

8

029 2085 8200

CIBSE Guide B 2.3.8.2 Requirements – It is stated that “Overall ventilation rates of between 0.5 and 1 air change per hour are generally appropriate, however, where possible, residents should be able to maintain autonomy and control over their immediate environment”. The degree of occupant control available must be considered with regard to the capabilities of the occupants. It is therefore recommended that baseline conditions are maintained automatically, with provision for authorised personnel to alter conditions by a relatively small amount – or for a limited time, before returning to default conditions. In accordance with normal design practice, the ventilation provision for higher occupancy zones should be based on commercially acceptable ventilation rates of 10 l/s per person, ideally with demand control. For dining rooms, 1 ach is appropriate, and for “process” (e.g. laundry, kitchen) areas, specific design guidance should be followed depending on the activity levels.

For example DW172 (Specification for kitchen ventilation systems. www.hse.gov.uk) may be suitable for larger premises with extensive catering needs.

Provision should be made to include an appropriate smoke control system. Approved Document B Volume 2, addresses Fire Safety within Buildings other than Dwelling Houses.

SUMMARY The importance of a suitable ventilation system should not be underestimated and there are a number of ways the required performance standards for ventilation can be met. Each of these has their advantages and disadvantages and the decision regarding which one to implement will be based on various criteria. The choice to some extent will be dependent upon whether it is a new build or refurbishment project. For multi-room requirements a zonal heat recovery supply and extract unit with 80%+ efficiencies would provide the most efficient solution. However regardless of the system output, regular maintenance is required to ensure the system efficiencies are maintained.


Complying with Building Regulations

Section 6

The following information is relevant to the selection of fans for Ventilation Systems, indicating the maximum specific fan powers allowed under Part L (Refer to the Non-domestic Building Services Compliance Guide: 2013 Edition for further details).

Permissible maximum specific fan power and pressure drop in air distribution systems.

The SFP for the entire system (including both supply & extract fans) shall be less than that allowed by these figures. The following tables are the maximum values allowed under Building Regulations when finally commissioned. Air distribution system

Specific fan power (SFP)10 (W/(l/s)) New Buildings Existing Buildings

Central balanced mechanical ventilation system 1.6 with heating and cooling

2.2

Central balanced mechanical ventilation system 1.5 with heating only

1.8

All other central balanced mechanical ventilation systems

1.6

1.1

Zonal supply system where the fan is remote 1.1 from the zone, such as ceiling void or roof mounted units

1.4

Zonal extract system where fan is remote from zone

0.5

0.5

Zonal supply and extract ventilation system 1.9 such as ceiling void or roof units serving a single room or zone with heating and heat recovery

1.9

Local balanced supply and extract ventilation system / such as wall roof units serving a single area with heating and heat recovery

1.6

1.6

Local supply or extract ventilation units such as window / wall / roof units serving a single area (e.g. toilet extract)

0.3

0.4

Other local ventilation supply or extract units

0.5

0.5

Fan assisted terminal (VAV) unit

1.1

1.1

Fan coil units (rating weighted average*)

0.5

0.5

Kitchen extract, fan remote from zone with grease filter

1.0

1.0

*Note: The weighted average is calculated by the following formula: Pmains,1.SFP1 +Pmains,2.SFP2 +Pmains,3.SFP3 +... Pmains,1+Pmains,2+Pmains,3+... where Pmains is useful power supplied from the mains in W Extending SFP for additional components in new and existing buildings Component (SFP (W/(l/s)) Additional return filter for heat recovery

+0.1

HEPA filter

+1.0

Heat recovery - thermal wheel system

+0.3

Heat recovery - other systems

+0.3

Humidifier / dehumidifier (air conditioning system)

+0.1

Air distribution system

Maximum permissible specific fan power (watts / litre/s)

Maximum external system pressure drop (Pa)

Central mechanical ventilation system including 1.8 heating, cooling and heat recovery

400 supply 250 extract

Central mechanical ventilation system including 1.8 (2.2) heating and cooling

400 supply 250 extract

Central mechanical ventilation system including 1.6 (1.6) heating only

400 supply 250 extract

All other central mechanical ventilation systems 1.4 (1.8)

400 supply 250 extract

Zonal supply system where the fan is remote from the zone, such as ceiling void or roof mounted units

1.2 (1.5)

200

Zonal extract system where the fan is remote from the zone

0.6 (0.6)

200

Zonal supply and extract ventilation units such 2.0 (2.0) as ceiling void or roof units serving a single room or zone with heating and heat recovery

150

Local supply and extract ventilation system such 1.8 (1.8) as wall / roof units serving a single area with heating and heat recovery

150

Local supply or extract ventilation units such as window / wall / roof units serving a single area (e.g. toilet extract)

0.4 (0.5)

30

Other local ventilation units

0.6 (0.6)

30

Fan assisted terminal variable air volume (VAV) unit

1.2 (1.2)

30

Fan coiled units

0.6 (0.6)

30

Note: 1. For existing buildings the maximum permissible specific fan power is given in brackets.

Example: For a central mechanical ventilation system with heating and cooling, and heat recovery via a plate heat exchanger plus return filter: SFP = 1.6 + 0.3 + 0.1 W/(l/s) = 2.0 W/(l/s) Recommended minimum dry heat recovery efficiency for heat exchangers in new and existing buildings Heat exchanger type Dry Heat recovery efficiency Plate heat exchanger

50%

Heat pipes

60%

Thermal wheel

65%

Run around coil

45%

For more details about ventilation systems for Student Accommodation and Care Homes refer to the ‘Product Navigator’ on Page 10. Alternatively contact Nuaire on 02920 858 200

nuaire.co.uk

9


Application & Product Selector LOCAL UNITS Single Room, Single Fan / HRU ducted to external wall. ZONAL & CENTRALISED UNITS Central system ducted to Roof / Plantroom Fan / HRU. COMBINED LOCAL, ZONAL & CENTRALISED UNITS Room Fan / HRU ducted to Central System to Roof Fan.

Combined unit and central duct

Cluster 4+ bedrooms with kitchen

l

l

l

l

l l l l

l l l l

l l l

l l l

l l l l

l l l l l l

l l l l

l l l l l l

l l l l

l l l l l l

l l l l

l l

l l l l l l

l l

l l

l l l

l l l

l l

l l l l l

l l

l l l l l

l

MRXBOX95AB-WM1

Up to 52l/s

MRXBOX95AB-WM2

Up to 90l/s

MRXBOX95AB-WH1

Up to 110l/s

MRXBOX95AB-WH2

Up to 180l/s

COOKER HOOD

Up to 117l/s

XS 6, 9,12 (Heat Recovery)

DUCTED IN CEILING VOID UNITS (Extract) ES-OPUS DC

Up to 110l/s

MEVDC

Up to 98l/s

MEVDC2

Up to 98l/s

MEVAC

Up to 95l/s

AVS/AVS CP

Up to 1.8m3/s

AVT/AVT CP

Up to 1.8m3/s

l l

(Heat Recovery) MRXBOX95B-LP1E

Up to 78l/s

OPUSXBOX

Up to 75l/s

MIDI-XBOX

Up to 145l/s

XBOXER XBC10, 15, 25

Up to 0.79m3/s

XBOXER XBC10, 15, 25 CP Up to 0.79m3/s PLANT ROOM/EXTERNAL UNITS (Extract) AVS/AVS CP

Up to 1.8m3/s

AVT/AVT CP

Up to 1.8m3/s

ESX/ESX CP

Up to 2.4m3/s

EST/EST CP

Up to 2.4m3/s

(Heat Recovery) XBOXER XBC/WP

10

Up to 0.79m3/s 3

XBOXER XBC/WP CP

Up to 0.79m /s

BOXER BESPOKE

Up to 20m3/s

029 2085 8200

l l

l l

l l

l l

l l

Combined unit and central duct

1, 2 and 3 Bedroom apartment

l l l l

Up to 530l/s

Up to 95l/s

Cluster 4+ beds/ kitchen centralised

Combined unit and central duct

l l l l

l l

Up to 31l/s

OPUS 40/60/90*

Bedsit with kitchen centralised

l l l l

l l

GENIE DC

Bedsit with kitchen

l l l l

Combined unit and central duct

l l l l

Single room ensuite centralised

l

l l l l

Single room with ensuite

WALL & CEILING MOUNTED UNITS (Extract)

1, 2 and 3 Bedroom apartment centralised

STUDENT ACCOMMODATION

l l l l

l l l l

l l l l

l l l l

l l l l

l l l l

l l l l

l l l l

l l l

l l l

l l l

l l l

l l l

l l l

l l l

l l l


l l l l

l l l l

l l l l

l l l l l l

l l l l

l l l l l l

l l l l

l l l l l l

l l

l l l

l l l l l l

l l l l

l l

l l

l l

l l

l l

l l

l l l l

Combined unit and central duct

l l l l

Bedroom with ensuite centralised

l

Bedroom with ensuite

l

l

Combined unit and central duct

l

l

l l

1 and 2 Bedroom apartment centralised

1 and 2 Bedroom apartment

l l l l

Bedsit with kitchen centralised

l l l l

l l

Bedsit with kitchen

l l l l

l l

l

l l l l

l l

l l l l

HOTEL ACCOMMODATION Combined unit and central duct

Combined unit and central duct

Single room ensuite centralised

Single room with ensuite

CARE HOME ACCOMMODATION

l l

*Refer to I&M document for details. WARRANTY* (YEARS) 5 5 2 5

l

5 5 5 5

l l l l l l

l l l

5 5 5 3 5 5

5 5 5 5 5

l l l l

l l l l

l l l l

l l l l

l l l l

l l l l

l l l l

l l l l

l l l

l l l

l l l

l l l

l l l

l l l

l l l

l l l

5 5 5 5

STOCKED ITEM

4 4 4 4

PAGE NUMBER 19 19 20 20

4 4 4 4

21 21 22 23

4 4 4 4 4 4

25 25 25 25 26 26

4 4 4 4 4

26 27 27 27 27

4 4 4 4

29 29 29 29

30

5

4 4

2

N/A

31

5

30

nuaire.co.uk

11


Student Accommodation

THE LAST THING ON A STUDENT’S MIND IS THE AIR QUALITY OF THE ACCOMMODATION THEY LIVE IN! (Model: MRXBOX95AB-WH2). Heat recovery unit mounted in a kitchen cupboard.

With the increase in student numbers comes the need for student accommodation covering all types of properties from specifically designed student blocks through to individual refurbished houses. Student accommodation can feature central heating, communal lounges and kitchens, individual bedroom/ studying areas with en-suite shower rooms through to 4 -12 bedroom clusters. Nuaire appreciates that Student accommodation often requires unique solutions. With this in mind, Nuaire has developed a wide range of ventilation products to ensure the highest level of indoor air quality with the lowest level of occupier interaction. Mechanical extract with heat recovery for ‘living’ and communal areas: (MRXBOX95, XBC, OPUSXBOX). Heat recovery systems offer efficiency and control over the air quality and volume within the accommodation. Providing tempered air into ‘living’ areas whilst extracting moisture laden air from ‘wet’ areas. Heat recovery is ideal for student and other multi-storey accommodation. Mechanical Extract for bathrooms, toilets and kitchens: (Genie, XS, AVS, AVT & MEV). Nuaire offers a wide range of extract fans for wall, window, roof and ceiling/void applications. Fans can be located in wet rooms, kitchens, utility areas and roof, extracting from wet areas and kitchens whilst providing continuous fresh air via trickle ventilators. Constant Pressure for multi-room ventilation: (AVT-CP, AVS-CP, XBC & BOXER Bespoke). Why ventilate empty rooms? Constant pressure is ideal for student accommodation. A central extract system provides the necessary extraction, linked to all ‘wet’ areas such as bathrooms via a central fan, which is normally positioned on a roof and unique direct-acting multi position CVD dampers or NRG grilles ensures operation only when room is occupied.

ZONAL & CENTRALISED UNITS

Ventilation control for added safety Airemiser is a temperature and/or current sensing control device that activates an extract fan when either a cooker, bath or shower is being used – this is particularly useful in student accommodation and care homes. Airemiser as part of a balanced ventilation system will help prevent condensation problems and can assist in the reduction of false fire alarms (a requirement of BS 5839-1:2002 section 3).

12

029 2085 8200

OPUSXBOX & MIDI-XBOX (up to 145l/s) Compact heat recovery up to 70% efficient. Ideal for up to 7 cluster bedrooms.

XBOXER XB HRU’s (up to 5m3/s) High performance heat recovery up to 70% efficient. Ceiling void, plant room or roof top varients.

XBOXER XBC (up to 0.79m3/s) Market leading heat recovery units, up to 95% efficient.


(Model: AVT9-R) Aire-Volve external roof mounted unit fitted with an Aire-Volve external unit grille assembly.

LOCAL UNITS

GENIE DC (up to 31l/s) A market leading 100mm bathroom and kitchen extract range for wall and ceiling applications. OPUS 40/60/95 (up to 95l/s) High performance wall and ceiling extract range complete with Ecosmart control. ES OPUS DC (up to 110l/s) High performance, low noise ceiling void extract range with very low profile complete with Ecosmart control. XS 6/9/12 (up to 530l/s) High performance multi-purpose wall, ceiling, panel and roof extract fans.

COOKER HOOD High performance, stainless steel 600mm unit with 117l/s extraction capacity. MEV FAMILY (up to 98l/s) Low depth multi-point ceiling void extract range. NEW - dMEV, contact Nuaire. MRXBOX95 SERIES (up to 180l/s) Compact heat recovery range for wall and cupboard applications.

BOXER BESPOKE (up to 20m3/s) Designed to meet project specific applications. Includes rotary wheels, plate heat exchangers & run around coils.

AVTCP & AVSCP (up to 1.8m3/s) Market leading low profile Single & Twin fans. Very low energy consumption and SFP’s.

ESXCP & ESTCP (up to 2.4m3/s) High performance single and twin fan ranges for Internal and external applications.

CONSTANT PRESSURE DAMPERS (CP) Energy efficient volume control damper for use with constant pressure fans. Wall (NRG) or duct (CVD) mounted.

MRXBOX95B-LP1E Low profile with a thermal efficiency of up to 80%. Ecosmart ready.

nuaire.co.uk

13


Care Home Accommodation

IN HEALTHCARE ENVIRONMENTS MAINTAINING A CONTINUOUS BALANCED VENTILATION SYSTEM IS A NECESSITY

Whether ventilating individual apartments, service rooms or the manager’s office, Nuaire is able to offer a wide range of product solutions for all care home requirements. Within the healthcare sectors, employers have an additional duty of care towards their staff with regards to passive smoking, satisfactory air quality and thermal comfort. Building security and eliminating cold spots and drafts may mean windows will need to be kept closed creating barriers for providing the duty of care to patients and workers alike. However, Nuaire can provide systems to suit all of these particular requirements. Extract for bedroom & personal living areas: (Genie, Opus or XS). Nuaire is renowned for its wall, duct, ceiling, window and wall fans. Nuaire’s expansive ranges are suitable for individual rooms to multi-room ducted ventilation. Heat recovery whole house ventilation – (MRXBOX95 family, OPUSXBOX & XBC10). Heat recovery offers efficiency and control over the air quality and volume with the building. Providing tempered air into ‘bedroom’ areas whilst extracting moisture laden air from ‘wet’ areas. Single & twin fans for toilet extract: (OPUS 40,60 & 95, OPUSDC, AVS, AVT, EST & MEV). A wide range of extract fans are available for applications such as toilet extract. From small and compact moulded single and twin fans that are located above the ceiling to large roof mounted external single and twin fans. High performance extract for communal living areas: (Boxer Bespoke, Ecosmart Boxer, Airevolve AVS and Xtractor). Nuaire has a wide portfolio of extract fans including ceiling void, plant room and roof top ranges which are suitable for multi-room living areas.

High performance supply & extract for kitchen areas: (SQF, Twin SQF and XBOXER). Nuaire produces a range of high performance supply & extract fans suitable for larger commercial kitchens incorporating some of the following features: • Optional out of air stream motors • High temperature operation ideal for kitchen canopy applications • Day to day smells and smoke extract (Model: MRXBOX95AB-WH2). Heat recovery unit mounted in a kitchen cupboard.

14

029 2085 8200


(Model: XS6WA) High performance multipurpose extract unit wall mounted.

LOCAL UNITS

GENIE DC (up to 31l/s) A market leading 100mm bathroom and kitchen extract range for wall and ceiling applications. OPUS 40/60/95 (up to 95l/s) High performance wall and ceiling extract range complete with Ecosmart control. ES OPUS DC (up to 110l/s) High performance, low noise ceiling void extract range with very low profile complete with Ecosmart control. XS 6/9/12 (up to 530l/s) High performance, multi-purpose wall, ceiling, panel and roof extract fans.

COOKER HOOD High performance, stainless steel 600mm unit with 117l/s extraction capacity. MRXBOX95 SERIES (up to 180l/s) Compact heat recovery range for wall and cupboard applications.

ZONAL & CENTRALISED UNITS

XBOXER XBC (up to 0.79m3/s) Market leading heat recovery units, up to 95% efficient.

BOXER BESPOKE (up to 20m3/s) Designed to meet project specific applications. Includes rotary wheels, plate heat exchangers & run around coils.

AVTCP & AVSCP (up to 1.8m3/s) Market leading low profile Single & Twin fans. Very low energy consumption and SFP’s.

ESXCP & ESTCP (up to 2.4m3/s) High performance single and twin fan ranges for internal and external applications.

CONSTANT PRESSURE DAMPERS (CP) Energy efficient volume control damper for use with constant pressure fans. Wall (NRG) or duct (CVD) mounted.

nuaire.co.uk

15


Hotel Accommodation

OPTIMISED VENTILATION SOLUTIONS HELPING TO CREATE A PLEASANT INDOOR AIR QUALITY IN THE MOST ENERGY EFFICIENT WAY

Hotels, like any other multi-storey accommodation, have their own unique requirements for ventilation. Maintaining a comfortable, healthy environment whilst providing an energy efficient solution is a must. Mechanical extract with heat recovery for ‘bedrooms’ and communal areas: (MRXBOX95, XBC, OPUSXBOX). Heat recovery systems offer efficiency and control over the air quality and volume within the accommodation. Providing tempered air into bedroom areas whilst extracting moisture laden air from ‘wet’ areas. Heat recovery is ideal for multistorey accommodation. Mechanical Extract for bathrooms, toilets and kitchens: (Genie, XS, AVS, AVT & MEV). A wide range of extract fans are available for applications such as toilet extract. From small and compact moulded single and twin fans that are located above the ceiling to large roof mounted external single and twin fans. Constant Pressure for multi-room ventilation: (AVT-CP, AVS-CP, XBC & BOXER Bespoke). Why ventilate empty rooms? Constant pressure is ideal for hotel accommodation. A central extract system provides the necessary extraction, linked to all ‘wet’ areas such as bathrooms via a central fan, which is normally positioned on a roof and unique direct acting multi-position CVD dampers and NRG grilles ensure operation only when room is occupied. Stairwell pressurisation & smoke extract for multi-floor requirements Nuaire has manufactured smoke ventilation for over 30 years including a complete range of smoke pressurisation and extract fans (duct or roof mounted) for 300/400OC for 1 & 2 hours, certified to EN12101-3 2002. High performance extract for communal living areas: (Boxer Bespoke, Ecosmart Boxer, Airevolve AVS and Xtractor). Nuaire has a wide portfolio of extract fans including ceiling void, plant room and roof top ranges which are suitable for multi-room living areas.

16

029 2085 8200

ZONAL & CENTRALISED UNITS (Model: AXT) Stairwell pressurisation system mounted on the roof.

High performance supply & extract for kitchen, bars and lounges: (SQF, Twin SQF and XBOXER). Nuaire produce a range of high performance supply & extract fans incorporating some of the following features: • Optional out of air stream motors • High temperature operation ideal for kitchen canopy applications • Day to day smells and smoke extract

BOXER BESPOKE (up to 20m3/s) Designed to meet project specific applications. Includes rotary wheels, plate heat exchangers & run around coils.


(Model: Aire-Volve AVTCP9-R). External roof mounted twin fan fitted with an external unit grille assembly.

LOCAL UNITS

OPUS 40/60/95 (up to 95l/s) High performance wall and ceiling extract range complete with Ecosmart control.

ES OPUS DC (up to 110l/s) High performance, low noise ceiling void extract range with very low profile complete with Ecosmart control. XS 6/9/12 (up to 530l/s) High performance, multi-purpose wall, ceiling, panel and roof extract fans.

SQUIF (up to 6.5m3/s) Inline unit with motor out of air stream. Cost effective low maintenance. Easy to install and suitable for external mounting. Ambient and High temperature ranges.

ECOSMART AIRMOVER (up to 10.6m3/s) High performance backward curved Centrif, exceptionally quiet, low maintenance, easy to install and suitable for external mounting.

AVTCP & AVSCP (up to 1.8m3/s) Market leading low profile Single & Twin fans. Very low energy consumption and SFP’s.

CONSTANT PRESSURE DAMPERS (CP) Energy efficient volume control damper for use with constant pressure fans. Wall (NRG) or duct (CVD) mounted.

XBOXER XBC (up to 0.79m3/s) Market leading heat recovery units, up to 95% efficient.

AXT STAIRWELL PRESSURISATION SYSTEM (up to 73m3/s) High temperature ‘run & standby’ axial fan Ideal system for stairwell pressurisation. Optional access doors make observation, & maintenance very quick & easy to install.

nuaire.co.uk

17


Wall & Ceiling Mounted Units - Options

(Model: MRXBOX95AB-WH2). Heat recovery unit mounted in a kitchen cupboard.

(Model: COOKERHOOD DC-SS). High performance extract cookerhood mounted in a kitchen.

(Model: GENIE-DC). Extract fan wall mounted, in a bedroom.

For further technical information on product ranges refer to Fan Selector. Details of how to download Fan Selector can be found on page 5. ECOSMART SENSORS & ENABLERS*

Touch screen.

18

Room and duct mounted CO2.

PVC GRILLES & DUCTING

PIR, temperature & relative humidity sensors.

Contact Nuaire for details

* Available on certain models only, call Nuaire for details.

029 2085 8200


WALL & CEILING MOUNTED UNITS TECHNICAL INFORMATION

GENIE DC - Extract range for wall and ceiling applications. (Code: GENIE-DC)

5 YEAR WARRANTY

The Genie DC combines the latest energy saving technology to a proven and popular design, providing over 80% lower running costs compared to traditional fans. (up to 30l/s). • NEW PART F & L UNDER (SYSTEM 1) Intermittent extract fans. Scottish building regs for intermittent bathroom extract fans. BRE digest 398 under continuous mechanical extract ventilation. Meets minimum fan power requirement in ‘Domestic Building Services Compliance Guide’ (2010 edition).

• MOUNT ANYWHERE Install in the wall, ceiling or window. Low profile recess option is available. • IDEAL FOR HIGH RISE BUILDINGS Fan is capable of maintaining the set flow rate to within 5% even under wind load conditions.

• CLIP-IN PUSH-FIT COMPONENTS Ensure reduced time on site. Replace your Genie internal components with latest energy saving technology. • ECONOMICAL Daily running cost is 80% lower than AC fans due to low wattage motor technology.

PERFORMANCE

• POWERFUL, YET COMPACT Up to 30l/s for the bathroom fan.

120 V

100

Full speed - Boost

Fan Static Pressure (Pa)

80

ISO 5801 BS848 Part 1 2007

DIMENSIONS (mm)

• COMPLETE USER SAFETY Robust flame retardant construction.

60

200 Minimum speed Background Ventilation

40 20 0

0 4 8 12 16 Air volume flow rate (l/s)

20

24

28

32

173

For further information on our extensive ducting ranges please refer to the website www.nuaire.co.uk

126

OPUS 40 / 60 / 95 Single & twin fans - High performance wall and ceiling extract range. (Code example: OPUS 40S)

5 YEAR WARRANTY

The Nuaire range of Opus 230V wall and ceiling mounted fans have been specifically designed to ventilate areas such as the bathroom, toilet, stores, drying rooms, cupboards etc. (up to 95l/s). • VERY QUIET OPERATION Units offer high performance with low noise levels. • MOST EFFICIENT SYSTEMS Latest DC motor design providing high performance with the lowest possible specific fan power available in its class.

• LOW MAINTENANCE COST Easy clean foam filters (metal filter on kitchen fan) protect motor and fan assembly, reducing maintenance costs and extending fan life.

• GUARANTEED VENTILATION The most compact cost effective twinfan available for the duty range.

DIMENSIONS (mm)

• QUICK & EASY TO INSTALL Installation as recessed or surface mounted on site. • SIMPLE TO COMMISSION Integral control facility enables the duty to be precisely set without additional controls.

225

PERFORMANCE 350 V

307

154

Open inlet dBA @ 3m 36 43 46

FLC amps 0.1 0.32 0.6

300

Fan Static Pressure (Pa)

250 Opus 95

200

ISO 5801 BS848 Part 1 2007

150

50

Fan Unit Opus 40 Opus 60 Opus 95

Opus 60

100 Opus 40

0 0 20 40 Air volume flow rate (l/s)

ELECTRICAL AND SOUND

60

80

Frequency Hz 63 125 250 45 47 53 48 57 57 50 57 62

500 49 55 58

1K 47 54 57

2K 48 55 57

4K 43 51 52

8K 33 44 46

Power 14 43 72

100

Note: OPUS 95 has 2/3rds duty on fan failure..

nuaire.co.uk

19


WALL & CEILING MOUNTED UNITS TECHNICAL INFORMATION

XS 6 / 9 / 12 - High performance multi-purpose wall, and ceiling extract units. (Code example: XS6 CL)

3 YEAR WARRANTY

Wide range of multi-purpose extract fans to suit most applications including wall, and ceiling (6, 9 and 12") with optional integrated controls. (up to 530l/s). • QUIETEST OPERATION With wax thermo actuator and market leading motor and impeller.

• SAVE ENERGY & MONEY With economy speed setting. • REVERSIBLE FOR EXTRACT AND INPUT With infinitely variable speed control.

• ‘MULTI’ FAN SPEED CONTROL Allows 5 fans to be connected to one speed control.

• OPTIONAL REFURB KITS Can be used to replace most existing systems.

(XS6 & 9 = up to 5 fans, XS12 = up to 3 fans).

PERFORMANCE Wall Fans. Performance for complete fan kit 120

Fan Static Pressure (Pa)

100 80

XS12 extract

V

XS6 extract XS9 extract

60

XS12 supply

40 20

ISO 5801 BS848 Part 1 2007

Fan Static Pressure (Pa)

6 inch Fan

A = 272 B = 269 C = 129 9 inch Fan A = 342 B = 342 C = 130 12 inch Fan A = 420 B = 420 C = 169

XS9 supply 400

XS12 extract XS6 extract

500

BS848 Part 1 2007

XS9 extract

40

XS6 supply

XS9 supply

C

A

B

C

A

B

XS6CL XS9CL XS12CL

Noise/Sound levels (dBA @ 3m) Extract Extract Supply economy 42 31 45 41 30 43 49 38 48

Input power (watts) Standard Economy

Supply economy 35 32 37

38 50 100

20 37 70

XS (WA) WALL FANS ELECTRICAL AND SOUND ISO 5801

60

A = 269 B = 128 C = 272 9 inch Fan A = 342 B = 130 C = 342 12 inch Fan A = 420 B = 169 C = 420

V

80

20

6 inch Fan

Code XS6 supply

Ceiling Fans. Performance for complete fan kit

100

DIMENSIONS (mm) - XS (WA) WALL FANS

XS (CL) CEILING FANS ELECTRICAL AND SOUND

0 100 200 300 Air volume flow rate (l/s)

120

DIMENSIONS (mm) - XS (CL) CEILING FANS

XS12 supply

0 100 200 300 Air volume flow rate (l/s)

400

Code

Noise/Sound levels (dBA @ 3m) Extract Extract Supply economy XS6WA 42 31 45 XS9WA 45 34 45 XS12WA 47 36 47

Input power (watts) Standard Economy

Supply economy 34 34 36

38 50 100

20 37 70

500

For roof and window fans electrical and sound, visit www.nuaire.co.uk

COOKERHOOD - High performance extract fan. (Code: COOKERHOOD DC-SS) Modern and sleek in its design, the Cookerhood extract fan provides high performance ventilation that will keep your kitchen free from the odours, grease and smoke produced by cooking. • HIGH PERFORMANCE 117l/s extraction capacity through tangential motor. • EASE OF USE Simple push button control to generate speed and lighting. • EASY CLEAN Stainless steel 600mm cookerhood and integral grease filters. • OPTIONAL EXTRA Carbon filters for air recirculation. (2 required)

PERFORMANCE COOKERHOOD DC-SS 120 V

100 Speed 3 ISO 5801 BS848 Part 1 2007

80 Static Pressure (Pa)

2 YEAR WARRANTY

60 40 Speed 2

20 0

Speed 1 0 20 40 60 Air volume flow rate (l/s)

20

029 2085 8200

80

100

120


WALL & CEILING MOUNTED UNITS TECHNICAL INFORMATION

MRXBOX95AB-WM1 - Compact heat recovery range for wall and cupboard applications. (Code: MRXBOX95AB-WM1) MRXBOX95AB-WM1 is designed to provide optimised balanced (supply and extract) mechanical ventilation with heat recovery. MRXBOX95AB-WM1 uses the latest generation of low voltage DC fans and motors, counter flow heat exchanger and easy access to controls. • MEETS BUILDING REGULATIONS Part F&L - England & Wales. Scottish technical handbook BRE398 referenced). • COMPACT, LIGHTWEIGHT • LOW SPECIFIC FAN POWER High efficiency. • OPTIONAL INTEGRAL FROST PROTECTION

• PREVENTS CONDENSATION

DIMENSIONS (mm)

• INTEGRAL AUTOMATIC SUMMER BYPASS Air will automatically bypass the heat exchanger to deliver fresh clean air during warmer months.

468

5 YEAR WARRANTY

• ATTENUATION An extensive range available to help reduce duct noise. Contact Nuaire for details.

Extract Fan

Run on

Trickle

Boost

Supply Fan

Trickle

288

Boost

601

ELECTRICAL AND SOUND Curve 1

PERFORMANCE 350

Fan Static Pressure (Pa)

2

ISO 5801 2007 AMCA 300

300 250

V

200

Type D Air Density 1.2 kg/m3

3

1 150

4

2 100 3 50 5

0

4

5

0 10.0 20.0 30.0 Air volume flow rate (l/s)

40.0

50.0

60.0

Maximum power consumption (Watts) 71 Open inlet Open outlet Breakout 39 Open Inlet Open outlet Breakout 21 Open inlet Open outlet Breakout 10 Open inlet Open outlet Breakout 5 Open inlet Open outlet Breakout

Sound Power Levels dB re 1pW 63 125 250 500 1K 45 41 48 47 41 48 51 57 59 54 51 50 53 51 43 44 39 46 44 36 44 48 52 53 48 50 48 51 48 38 42 38 43 37 31 42 46 49 49 42 48 46 47 44 32 40 35 39 32 23 40 43 44 43 33 46 43 43 38 23 35 29 30 20 5 36 38 37 33 18 42 38 36 28 8

2K 39 47 38 34 41 33 26 35 27 18 20 18 11 3

4K 24 39 30 20 29 25 20 23 19 12 14 10 -

8K 24 33 26 19 25 21 17 19 15 9 13 6 -

dBA @3m 30 41 33 26 36 30 21 31 26 16 24 21 <10 15 13

For further information on our extensive ducting ranges please refer to the website www.nuaire.co.uk

MRXBOX95AB-WM2 - Compact heat recovery range for wall and cupboard applications. (Code: MRXBOX95AB-WM2) MRXBOX95AB-WM2 is designed to provide optimised balanced (supply and extract) mechanical ventilation with heat recovery. Tempered air is delivered into ‘living’ areas whilst extracting moisture laden air from ‘wet’ areas creating comfortable well ventilated homes. The unit has the facility to commission the supply & extract fans independently on both minimum and maximum speeds. • MEETS BUILDING REGULATIONS Part F&L - England & Wales. Scottish technical handbook BRE398 referenced). • COMPACT, LIGHTWEIGHT Simple to install. • LOW SPECIFIC FAN POWER High efficiency.

ELECTRICAL AND SOUND Curve 1

PERFORMANCE 600 ISO 5801 2007 AMCA 300

500 400

Fan Static Pressure (Pa)

2

V Type D Air Density 1.2 kg/m3

1

300 2

200

4

3 100

4 5

5

0 0 20 40 60 Air volume flow rate (l/s)

80

100

120

Maximum power consumption (Watts) 150 Open inlet Open outlet Breakout 75 Open inlet Open outlet Breakout 36 Open inlet Open outlet Breakout 14 Open inlet Open outlet Breakout 8 Open Inlet Open outlet Breakout

• INTEGRAL FROST PROTECTION

DIMENSIONS (mm)

• INTEGRAL AUTOMATIC SUMMER BYPASS Air will automatically bypass the heat exchanger to deliver fresh clean air during warmer months.

503

5 YEAR WARRANTY

• ATTENUATION An extensive range available to help reduce duct noise. Contact Nuaire for details. Sound Power Levels dB re 1pW 63 125 250 500 1K 57 57 61 56 50 55 65 71 67 64 61 61 56 53 47 51 51 55 48 40 53 59 61 58 55 56 55 51 44 38 48 48 48 42 33 52 56 55 53 49 52 54 47 39 33 44 44 39 34 27 51 52 49 48 43 49 52 44 34 29 40 39 25 22 18 50 48 41 41 36 46 50 39 27 22

353 603

2K 47 60 44 35 52 35 28 45 30 21 37 25 <16 24 19

4K 36 51 35 25 39 23 18 32 <16 <16 25 <16 <16 17 <16

8K 34 43 33 20 32 17 <16 25 <16 <16 18 <16 <16 <16 <16

nuaire.co.uk

dBA @3m 40 52 37 32 43 29 26 37 26 18 31 22 <16 24 18

21


WALL & CEILING MOUNTED UNITS TECHNICAL INFORMATION

MRXBOX95AB-WH1 - Compact heat recovery range for wall and cupboard applications. (Code: MRXBOX95AB-WH1)

5 YEAR WARRANTY

MRXBOX95AB-WH1 is designed to provide optimised balanced (supply & extract) mechanical ventilation with heat recovery. Tempered air is delivered into ‘living’ areas whilst extracting moisture laden air from ‘wet’ areas creating comfortable well ventilated homes. The unit has the facility to commission the supply & extract fans independently on both minimum and maximum speeds. The heat exchanger block can recover up to 95% of normally wasted heat. • MEETS BUILDING REGULATIONS Part F&L - England & Wales. Scottish technical handbook (BRE398 referenced). • LOW SPECIFIC FAN POWER High efficiency. Designed to meet the duty for medium to large properties including 3 storey.

• INTEGRAL FROST PROTECTION For cold weather protection. • INTEGRAL AUTOMATIC SUMMER BYPASS Air will automatically bypass the heat exchanger to deliver fresh clean air during warmer months.

• UNIT FITS EASILY INTO CUPBOARDS Saving valuable storage space. • QUIET RUNNING UNIT Ensuring occupant acceptability.

DIMENSIONS (mm)

• EASY ACCESS TO FILTERS FROM FRONT COVER

619

• DESCREET RUN MONITOR Records units operational time. • ATTENUATION An extensive range available to help reduce duct noise. Contact Nuaire for details.

431 654

PERFORMANCE

ELECTRICAL AND SOUND

Curve 1

500 ISO 5801 2007 AMCA 300

V

400

Type D Air Density 1.2 kg/m3

Fan Static Pressure (Pa)

300

2

1 2

3

3

200

4

4 100 5 6

5

0 0 25 50 Air volume flow rate (l/s)

75

100

125

6

Maximum power consumption (Watts) 150 Open inlet Open outlet Breakout 114 Open inlet Open outlet Breakout 75 Open inlet Open outlet Breakout 36 Open inlet Open outlet Breakout 14 Open Inlet Open outlet Breakout 8 Open inlet Open outlet Breakout

Sound Power Levels dB re 1pW 63 125 250 500 1K 48 51 58 49 47 56 63 67 67 62 56 61 59 53 43 48 50 57 48 45 56 62 66 66 60 56 60 58 52 41 47 50 56 46 43 55 62 65 64 58 55 60 57 50 39 46 48 53 43 37 54 60 62 61 52 54 58 54 47 33 44 45 50 38 30 52 57 59 56 45 52 55 51 42 26 41 42 44 30 19 49 54 53 48 34 49 52 45 34 <16

2K 39 60 40 37 58 38 35 56 36 29 50 30 22 43 23 <16 32 <16

4K 25 50 25 23 48 23 21 46 21 <16 40 <16 <16 33 <16 <16 22 <16

For further information on our extensive ducting ranges please refer to the website www.nuaire.co.uk

22

029 2085 8200

8K <16 41 <16 <16 39 <16 <16 37 <16 31 <16 <16 24 <16 <16 <16 <16

dBA @3m 31 47 33 30 45 32 29 44 31 25 40 28 22 35 24 <16 27 19


WALL & CEILING MOUNTED UNITS TECHNICAL INFORMATION

MRXBOX95AB-WH2 - Heat recovery range for wall and cupboard applications. (Code: MRXBOX95AB-WH2)

5 YEAR WARRANTY

A high duty MVHR unit with low specific fan power (SFP). Designed to meet the requirements of larger properties (Up to 180l/s), providing a versatile, cost effective, energy efficient ventilation solution. This whole house mechanical ventilation heat recovery system combines supply and extract in one unit. Low watt EC fans combined with high efficiency impellers provides extremely quiet running and long life motors. EC fans will also reduce power consumption, operating, and the life cycle costs. • MEETS BUILDING REGULATIONS Part F&L - England & Wales. Scottish technical handbook (BRE398 referenced).

• INTEGRAL FROST PROTECTION (-5 degrees C as standard).

• EASY TO INSTALL

• PREVENTS CONDENSATION Keeping moisture levels low.

• FAN CONTROLS Designed for quick and easy commissioning.

• SIGNIFICANT ENERGY SAVINGS Very low running costs, due to EC fan motors.

• OPTIONAL WIRELESS CONTROL (MRXBOX95AB-WH2WC).

DIMENSIONS (mm)

• EASY ACCESS TO FILTERS FROM COVER No tools required.

710

• HEAT RECOVERY EFFICIENCY In excess of 85%. • CONSTANT QUIET RUNNING FANS Ensuring occupant acceptability. • INTEGRAL AUTOMATIC SUMMER BYPASS 585

• SUMMER BOOST FACILITY 710

• INTEGRAL HUMIDITY SENSOR (Set point adjustment). • ATTENUATION An extensive range available to help reduce duct noise. Contact Nuaire for details.

PERFORMANCE

ELECTRICAL AND SOUND

800

ISO 5801 2007 AMCA 300

700

V Type D Air Density 1.2 kg/m3

600 500

Curve 1

Maximum power consumption (Watts) 337 Open inlet Open outlet Breakout

Sound Power Levels dB re 1pW 63 125 250 500 1K 58 56 57 63 57 67 63 65 75 68 61 61 60 63 53

2K 51 63 48

4K 46 56 40

8K 45 53 35

dBA @3m 61

Fan Static Pressure

400

Above noise measured at stated percent of maximum working pressure. 300 200 100 0 0 40 80 120 Air volume flow rate (l/s)

160

180

200

ALSO FROM NUAIRE New range of thermal ducting, an all-in-one insulated ducting system. (For further information on our extensive ducting ranges please refer to the website www.nuaire.co.uk

nuaire.co.uk

23


Ducted in Ceiling Void Units - Options

(Model: MEVDC-ES). Low depth multi-point unit mounted in the ceiling.

(Model: ES-OPUS DC). Low depth extract unit mounted in the ceiling.

(Model: XBC15). Low depth heat recovery unit mounted in the ceiling.

For further technical information on product ranges refer to Fan Selector. Details of how to download Fan Selector can be found on page 5. ECOSMART SENSORS & ENABLERS*

Touch screen.

24

Room and duct mounted CO2.

PVC GRILLES & DUCTING

PIR, temperature & relative humidity sensors.

Contact Nuaire for details

* Available on certain models only, call Nuaire for details.

029 2085 8200


DUCTED IN CEILING VOID UNITS TECHNICAL INFORMATION

ES-OPUS DC - Ceiling void extract range with low profile. (Code example: ES-OPUS DC40M)

5 YEAR WARRANTY

A compact in duct ceiling void fan offering high performance with low noise. Ideally suited to ceiling voids this ES-OPUSDC is ideal for simple commissioning for a guaranteed ventilation solution. • ADVANCED FAN MOTOR AND IMPELLER TECHNOLOGY Providing the quietest unit available.

• UNIQUE SELF LOCATING MOUNTING BRACKET Enables the unit to be quickly and efficiently installed.

• CONTINUOUS VENTILATION Twin fans allow for automatic changeover to stand by fan in the event of fan failure.

DIMENSIONS (mm)

184

• LATEST DC MOTOR DESIGN Providing high performance with the lowest possible Specific Fan Power available in its class. • SIMPLE COMMISSIONING Integrated speed control enabling minimum and maximum fan speed to be easily adjusted.

367

250

ELECTRICAL AND SOUND PERFORMANCE 400

V

300

ISO 5801 2007

FLC amps

Induct Inlet/outlet noise

Sound Power Levels dB re:10-12w Frequency Hz 125 250 500 1K 2K 4K 8K

Induct inlet Induct outlet Breakout levels Induct inlet Induct outlet Breakout levels

65 64 45 72 75 45

52 56 52 58 67 51

45 53 45 53 62 51

41 52 40 50 61 46

36 49 29 45 60 42

24 42 25 33 55 34

25 34 25 30 49 27

Induct inlet Induct outlet Breakout levels Induct inlet Induct outlet Breakout levels

65 64 45 72 75 45

52 56 52 58 67 51

45 53 45 53 62 51

41 52 40 50 61 46

36 49 29 45 60 42

24 42 25 33 55 34

25 34 25 30 49 27

Induct inlet Induct outlet Breakout levels Induct inlet Induct outlet Breakout levels

68 69 52 76 76 52

55 58 48 68 71 54

49 54 49 61 63 54

48 52 44 54 63 50

38 48 31 49 62 44

27 42 28 40 58 37

27 33 25 37 52 27

Curve

Code

1

Single Fan ES-OPUSDC40-M 18

0.13

2

ES-OPUSDC60-M 44

0.31

1

Twin Fan ES-OPUSDC40-2M 18

0.13

2

ES-OPUSDC60-2M 44

0.31

3*

Dual Fan ES-OPUSDC75-M 33

0.23

4*

ES-OPUSDC110-M 90

0.6

Tested in duct

350

Input Power Watts

4 Fan Static Pressure (Pa)

250 200 150 3 100 50 1

2

0 0 20 40 60 Air volume flow rate (l/s)

80

100

120

Note: Sizes 75 and 110 have 2 fans running simultaneously. In the event of failure the remaining fans performance will be reduced to approximately 2/3rds.

Breakout dBA@3m 29

34

29

34

30

37

For further information on our extensive ducting ranges please refer to the website www.nuaire.co.uk

MEVDC-ES - Low depth multi-point ceiling void extract range. (Code example: MEVDC-ES)

5 YEAR WARRANTY

A range of multi-point energy efficient, low depth central extract fans. Unique locating bracket can be fixed in any plane – ideal for 1st or 2nd fix. (Up to 98 l/s duty range). • MEETS BUILDING REGULATIONS SAP Appendix Q recognised. Part F&L - England & Wales. Scottish technical handbook (BRE398 referenced).

DIMENSIONS (mm)

• LATEST DC MOTORS Provide high performance with low SFP within class. • ADVANCED MOTOR AND IMPELLER TECHNOLOGY With acoustic lined lid (fully lined case option available).

PERFORMANCE

180

• ONLY 190MM DEEP AND UP TO 98L/S

490

350

• VISUAL AND AUDIBLE FAILURE INDICATOR 700

Tested in duct

600 500

Fan Static Pressure (Pa)

• ECOSMART ‘DIAL A DUTY’ OPTION

For details regarding MEVAC extract fans, contact Nuaire.

V ISO 5801 2007

ELECTRICAL AND SOUND

400

Curve

300 200 100 0 0 20 40 60 Air volume flow rate (l/s)

80

100

120

1 2 3 4

Power Consumption Watts 11 21 35 52

FLC Amps 0.14 0.19 0.25 0.37

Open inlet sound power levels dB re 1pW 63 125 250 500 1K 2K 4K 39 39 44 36 31 22 21 40 42 46 41 37 28 24 43 43 50 46 41 31 28 45 44 54 52 44 35 31

8K 18 18 27 27

Breakout Noise level dBA@3m 19 27 31 34

NEW - dMEV, contact Nuaire for details.

nuaire.co.uk

25


DUCTED IN CEILING VOID UNITS TECHNICAL INFORMATION

AVT / AVTCP & AVS / AVSCP - Market leading low profile single & twin fans. (Code example: AVT1)

5 YEAR WARRANTY

The new Aire-Volve single and twin fans from Nuaire meet the latest current legislation and building regulations, and are available for external and internal applications. Very low noise and SFP’s with built in energy efficient Ecosmart control. Powerful yet compact, the ideal solution for high performance extract 24/7. The range is Class L2 leakage. (Duty up to 1.7m3/s). • LATEST EC MOTOR TECHNOLOGY Guarantees longer life and lower SFPs.

• MANUFACTURED FROM ALUZINC Longer life expectancy than other materials.

• CONSTANT PRESSURE OPTION Improves the energy performance of the overall building & guarantees lower energy costs.

• GUARANTEES A SUPERIOR ACOUSTIC SOLUTION Fan and matching silencer system reduces breakout. • 12 HOUR AUTO CHANGEOVER Guarantees ventilation 24/7 in event of fan/motor failure and extends life of fan. (Twin fans only).

• BUILT-IN ECOSMART CONTROLS Energy efficient demand control ventilation solution.

PERFORMANCE 900 800

B1

A

ISO 5801 2007 AMCA 300

700 Fan Static Pressure (Pa)

Dim A. inc. end panels Code (77mm) AVS1 580 AVS2 615 AVS3 745 AVS4 788 AVS4L 914 AVS5 914 AVS6 1087 AVS7 1180 AVS8 1338 AVS9 1338

DIMENSIONS (mm) Internal Units

V

600

Type D Air Density 1.2 kg/m3

9

500

C

7

400

8

6

300 200

4

3 2

100

D

5

B

1

0

0 0.4 0.8 1.2 Air volume flow rate (m3/s)

1.6

2.0

Dim A. +spigot length (85mm) 665 700 830 873 999 999 1172 1265 1423 1423

B 535 535 672 672 822 822 915 1013 1237 1237

Dim B1 +control (108mm) NA 643 780 780 930 930 1013 1121 1345 1345

C 250 285 334 376 395 428 545 575 615 615

D 200 200 250 315 315 315 400 400 500 500

For external unit sizes refer to page 29.

MRXBOX95B-LP1E Ceiling void unit - Supply & extract ventilation with heat recovery. (Code: MRXBOX95B-LP1E)

5 YEAR WARRANTY

MRXBOX95B-LP1E is specifically designed for apartment applications where there are ceiling void limitations. The MVHR unit provides optimised balanced (supply & extract) mechanical ventilation with heat recovery. The unit has a facility to commission the supply & extract fans independently on both minimum and maximum speeds. • MEETS BUILDING REGULATIONS Part F&L - England & Wales. Scottish technical handbook (BRE398 referenced).

• INTEGRAL FROST PROTECTION For cold weather protection.

DIMENSIONS (mm)

• BUILT-IN ECOSMART CONTROL • BUILT-IN BYPASS

204 60

200

• LOW SPECIFIC FAN POWER High efficiency. • HIGH EFFICIENCY FILTERS Helps to create a healthy living environment.

900

700

ELECTRICAL AND SOUND

PERFORMANCE 600

ISO 5801 2007 AMCA 300

500

1

100

2

85

3

65

4

45

5

26

V Type D Air Density 1.2 kg/m3

400 Fan Static Pressure (Pa)

Curve

Maximum power consumption (Watts)

1

300 2

200 3

100

4 5

0

0 10 20 30 40 Air volume flow rate (l/s)

26

50

60

70

80

Open inlet Open outlet Breakout Open inlet Open outlet Breakout Open inlet Open outlet Breakout Open inlet Open outlet Breakout Open Inlet Open outlet Breakout

Sound Power Levels dB re 1pW 63 125 250 500 1K

2K

4K

8K

50 57 64 50 56 62 45 52 57 39 46 50 36 39 42

42 65 47 39 59 43 30 53 33 19 44 19 14 28 -

32 56 38 27 51 32 20 42 23 12 30 14 17 -

23 48 30 17 42 20 9 32 21 10 -

56 67 64 52 63 62 47 57 56 42 50 49 36 43 40

55 68 63 55 65 61 48 58 54 37 49 44 26 37 33

55 69 62 51 65 57 44 58 49 34 49 39 24 38 27

46 67 52 43 63 48 35 56 41 26 46 29 17 35 14

For further information on our extensive ducting ranges please refer to the website www.nuaire.co.uk

029 2085 8200

dBA @3m

43

40

33

23

12


DUCTED IN CEILING VOID UNITS TECHNICAL INFORMATION

OPUSXBOX & MIDI-XBOX - Compact ceiling void heat recovery units up to 75% efficient.

5 YEAR WARRANTY MIDI-XBOX Available March 2014

Small commercial heat recovery solutions, with low depth, multiple spigots and Ecosmart controls. Ideal for up to 7 cluster bedrooms and ceiling void applications. • QUIET SOLUTION Units are lined, advanced impeller technology ensures the quietest system possible.

• LOW MAINTENANCE • FLEXIBLE SOLUTION Supply & extract airflows are easily fine tuned using integral speed adjustment and built in dampers.

• HIGH EFFICIENCY Heat recovery efficiency in excess of 70% possible, this together with low watt d.c motors give energy savings.

DIMENSIONS (mm)

• MIDI-XBOX-100% SUMMER BYPASS

• ECOSMART CONTROL With optional sensors and enablers. (applies to Opusxbox only).

PERFORMANCE OPUSXBOX

PERFORMANCE MIDI-XBOX

500

175

Fan Static Pressure (Pa)

Fan Static Pressure (Pa)

937

Code example: OPUSXBOX

100%

200 3

75%

2

50%

100 1

25%

0 0 10 20 30 40 Air volume flow rate (l/s)

850

685

50

60

70

Type D Air Density 1.2 kg/m3

300

300 4

V

350

Type D Air Density 1.2 kg/m3

Code example: MIDI-XBOX

ISO 5801 2007 AMCA 300

400

V

400

300

450

ISO 5801 2007 AMCA 300

1080

250 MIDI-XBOX (Full Speed)

200

1

150 100 50 0

0 20 40 60 Air volume flow rate (l/s)

80

80

100

120

140

For further information on our extensive ducting ranges please refer to the website www.nuaire.co.uk

XBOXER XBC - Compact, low height heat recovery units, up to 95% efficiency. (Code example: XBC15-H-LES)

5 YEAR WARRANTY

New low height, constant pressure heat recovery units designed for ceiling void applications (suitable for external use with weather roof). See page 30. • NEW LOW HEIGHT, HEAT RECOVERY UNITS Designed for ceiling void applications. Designed to save energy, improve indoor air quality and provide the lowest noise breakout (when used as part of a system).

• MOST COMPACT & FLEXIBLE Lowest case height (by duty) with unique supply/ discharge are on unit centreline, intake/extract connections are configurable on site.

• LOWEST NOISE Guaranteed* quietest solution, units are aluzinc, Asymmetric, high mass, double skinned wall construction with specialist acoustic treatment designed to meet BB93 & BB103. Tested and certified by BSRIA.*

• OPTIMUM PERFORMANCE Backward curved impellers and IP54 EC motors provide low specific fan powers and stepless speed control without tonal noise generation. • PREMIUM QUALITY Manufactured in the UK, all units are tested to Class L2 leakage. Ecosmart (ES) and Ecosmart2 (NT) have a 5 year warranty with Basic control (BC) models having a 2 year warranty.

• SIMPLISTIC CONTROL SOLUTIONS Energy efficient Ecosmart ‘ plug and play’ control along with the addition of Ecosmart2 (powered by Trend).

DIMENSIONS (mm)

*Contact Nuaire for details.

PERFORMANCE 1000

ISO 5801 2007 AMCA 300

C

V

800

B

Type D Air Density 1.2 kg/m3

A

Unit code XBC10-* XBC15-* XBC25-* XBC45-* XBC55-* XBC65-*

Dimensions (mm) A B 1600 1000 1600 1000 1700 1150 1900 1250 1900 1560 1900 1560

C 260 260 340 400 470 620

Fan Static Pressure (Pa)

600

400

XBC15

XBC25

200

XBC10

XBC45

XBC55

XBC65

0 0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

Air volume flow rate (m3/s)

nuaire.co.uk

27


Plant Room & Roof Units - Options

(Model: Aire-Volve AVT1-9-R-MOD). External roof mounted twin fan fitted with an external unit grille assembly.

CVD Damper (optional).

28

029 2085 8200

(Model: Aire-Volve AVT3-CP). Wall mounted constant pressure twin fan mounted vertically in a plantroom.

NRG Control Grille/Damper (optional).

(Model: XBOXER XBC15-H-NTWP). External roof mounted air handling unit fitted with external weather roof.

For further technical information on product ranges refer to Fan Selector. Details of how to download Fan Selector can be found on page 5.


PLANT ROOM & ROOF UNITS TECHNICAL INFORMATION

AVT / AVTCP & AVS / AVSCP - Market leading low profile single & twin fans. (Code examples: AVS9-X & AVT9-R)

5 YEAR WARRANTY

The new Aire-Volve single and twin fans from Nuaire meet the latest current legislation and building regulations, and are available for external and internal applications. Very low noise and SFP’s with built in energy efficient Ecosmart control. Powerful yet compact the ideal solution for high performance extract 24/7. The range is Class L2 leakage. (Duty up to 1.7m3/s). • LATEST EC MOTOR TECHNOLOGY Guarantees longer life and lower SFPs.

• MANUFACTURED FROM ALUZINC Longer life expectancy than other materials.

• CONSTANT PRESSURE OPTION Improves the energy performance of the overall building and guarantees lower energy costs for end users.

• GUARANTEES A SUPERIOR ACOUSTIC SOLUTION Fan and matching silencer system reduces breakout.

• BUILT-IN ECOSMART CONTROLS Energy efficient demand control ventilation solution.

DIMENSIONS (mm)

PERFORMANCE

External units with & without grille assembly

Fan Static Pressure (Pa)

900 800

ISO 5801 2007 AMCA 300

A

700

V

600

Type D Air Density 1.2 kg/m3

9

500 400

6

300 200 100 0

C

7

3 2

4

8

5

D B

1 0 0.4 0.8 1.2 Air volume flow rate (m3/s)

1.6

• 12 HOUR AUTO CHANGEOVER Guarantees ventilation 24/7 in event of fan/motor failure and extends life of fan. (Twin fans only).

Dim A. Dim A. End+grille +spigot panels length Code (5mm) (50mm) AVT1-R 1620 1670 AVT2-R 1620 1670 AVT3-R 1620 1670 AVT4-R 2066 2116 AVT4L-R 2066 2116 AVT5-R 2066 2116 AVT6-R 2575 2625 AVT7-R 2575 2625 AVT8-R 2956 3006 AVT9-R 2956 3006

Dim B +control B (40mm) 716 756 716 756 716 756 857 897 857 897 857 897 1045 1085 1045 1085 1278 1318 1278 1318

C 393 393 393 502 502 502 656 656 709 709

*D 1120 1120 1120 1466 1466 1466 1831 1831 2172 2172

2.0

*D = Unit length for AVT1-9-X units without grille assembly.

ESXCP / ESTCP - Constant pressure single and twin fans. (Code examples: ESX11-X & ESTCP11-X)

5 YEAR WARRANTY

Comprehensive range of Constant Pressure twin fans from Nuaire with integral Ecosmart energy saving control. A low noise and powerful range ideal for high performance extract 24/7. Available in 3 mounting options (inline, end inlet and bottom inlet). Duty range up to 5.9m3/s. • LEADING SINGLE & TWIN FANS Integrated silencer (direct drive models) helps reduce noise and space requirements on site.

• BUILT-IN ECOSMART CONTROLS Energy efficient demand control ventilation solution.

• LATEST EC MOTOR TECHNOLOGY Guarantees longer life and lower SFPs.

• SIMPLE TO INSTALL All controls are pre-assembled and installed which ensures site time is kept to a minimum.

• CONSTANT PRESSURE OPTION Improves the energy performance of the overall building and guarantees lower energy costs for end users.

• 12 HOUR AUTO CHANGEOVER Guarantees ventilation 24/7 in the event of fan/motor failure and extends life of fan. (Twin fans only).

CONSTANT PRESSURE

NRG Control Grille/Damper (optional).

Humidity Control.

CVD Damper (optional).

nuaire.co.uk

29


PLANT ROOM & ROOF UNITS TECHNICAL INFORMATION

XBOXER XBC - Compact, low height heat recovery units, up to 95% efficiency.

5 YEAR WARRANTY

A lower casing height makes for an ideal solution for ceiling, underfloor or slab mounted applications. Side access is standard on XBC range however, bottom access is available, contact Nuaire for further details. XBC’s unique design of centre line supply/ discharge connections together with configurable intake/extract connections to either side of the unit provides multiple onsite flexibility. XBOXER’s high efficiency heat recovery units are designed to save energy, improve indoor air quality and provide the lowest noise breakout (when used as part of a system). By incorporating a high efficiency counter flow plate heat exchanger (up to 95% efficiency) together with a segmented 100% bypass facility (patent applied for) complete with automatic control and actuator. Four G4 filters are fitted as standard (other options available) in the XBC models two of which are spare for install and commissioning purposes and provide an extra 12 months of filtration. Units incorporate a choice of LPHW heater battery, valve and actuator or Electric heater battery and burst fired temperature controller. Alternatively a ‘No Heater’ version is also available. • NEW LOW HEIGHT, HEAT RECOVERY UNITS Designed for ceiling void applications (suitable for external use with weather roof). • LOWEST NOISE Guaranteed* quietest solution, units are aluzinc, asymmetric, high mass, double skinned wall construction with specialist acoustic treatment designed to meet BB93 & BB103. Tested and certified by BSRIA*.

MATCHING ATTENUATORS

• MOST COMPACT & FLEXIBLE Lowest case height (by duty) with unique supply/ discharge are on unit centreline, intake/extract connections are configurable on site.

Attenuator is easily configured for positioning on the right.

DIMENSIONS (mm)

C

• OPTIMUM PERFORMANCE Backward curved impellers and IP54 EC motors provide low specific fan powers and stepless speed control without tonal noise generation.

B

A

ECOSMART2 (NT) UNITS

ECOSMART (ES) & BASIC CONTROL (BC) UNITS

Unit size

Unit size

Dimensions (mm) A B C 1600 1000 260 1600 1000 260 1700 1150 340 1900 1250 400 1900 1560 470 1900 1560 620

XBC10-H-*NT XBC15-H-*NT XBC25-H-*NT XBC45-H-*NT XBC55-H-*NT XBC65-H-*NT

*Add relevant code ie: for battery type, L = LPHW, E = Electric, N = No heater

UNIT WITH WEATHER ROOF Suitable for external use. Code example: XBOXER XBC15-H-NTWP

• SIMPLISTIC CONTROL SOLUTIONS Energy efficient Ecosmart ‘ plug and play’ control along with the addition of Ecosmart2 (powered by Trend). *Contact Nuaire for details.

• MATCHED SILENCERS Help to reduce breakout and can be flipped 180 degrees on site to fit either side. (1000, 1250 and 1600mm lengths. Attenuator postioned on the left.

• PREMIUM QUALITY Manufactured in the UK all units are tested to Class L2 leakage. Ecosmart (ES) and Ecosmart2 (NT) have a 5 year warranty with Basic control (BC) models having a 2 year warranty.

PERFORMANCE

Dimensions (mm) A B C 1600 1000 260 1600 1000 260 1600 1000 260 1600 1000 260 1700 1150 340 1700 1150 340 1900 1250 400 1900 1250 400 1900 1560 470 1900 1560 470 1900 1560 620 1900 1560 620

XBC10-H-*ES XBC10-H-*BC XBC15-H-*ES XBC15-H-*BC XBC25-H-*ES XBC25-H-*BC XBC45-H-*ES XBC45-H-*BC XBC55-H-*ES XBC55-H-*BC XBC65-H-*ES XBC65-H-*BC

1000

ISO 5801 2007 AMCA 300

V

800

Type D Air Density 1.2 kg/m3

Fan Static Pressure (Pa)

600

400

XBC15

XBC25

200

XBC10

XBC45

0

0.1

0.2

Air volume flow rate (m3/s)

30

029 2085 8200

XBC55

XBC65

0 0.3

0.4

0.5

0.6

0.7

0.8

0.9


PLANT ROOM & ROOF UNITS TECHNICAL INFORMATION

BOXER BESPOKE - Customer defined Air Handling Units. Nuaire has a long and successful history in heat recovery and has been developing and manufacturing air handling units for many years. BOXER Bespoke air handling unit solutions can be tailor made to suit any application requirements and can include humidification, cooling, heating and filtration and now up to 20m3/s. • OUR CUSTOM MADE AIR HANDLING UNITS cover functions for applications with special demands: energy efficiency, high performance and fast commissioning are some of the qualities applied on packaged and custom air handling unit ranges.

• The pre-configured and tailored solution ranges can be combined to offer the best solution. The unit platform could be standardised, whereas a selection of the functions are customised making XBOXER the most flexible air handling unit range available.

• CUSTOMER DEFINED Customers now have the flexibility to combine modules to build tailor-made air handling units up to 20m³/s.

• PROJECT SPECIFIC CONTROL Air handling units are sent to site control free, allowing them to be integrated with control systems supplied by others.

• SPECIAL DEMAND For installations that demand functionality XBOXER can always offer a solution. For instance, the installation might require a humidifier in order to achieve a specific humidity level. The application environment might also require components in a specific finish, XBOXER can meet this requirement.

• ENERGY SOLUTIONS Nuaire also offers a number of world class solutions for energy efficiency.

• FLEXIBILITY The possibility to combine single and double deck units has been increased in combinations and sizes within this range. Installations with high demands might need one or a few functions outside the standard range.

At Nuaire, quality is the key component of all our products, whatever the application: • Suitable for all installations, internally and externally • A choice of materials • A choice of heat recovery options (including plate HX, thermal wheel and run-around coil)

PERFORMANCE 1000

ISO 5801 2007 AMCA 300

900

V Type D Air Density 1.2 kg/m3

800 700 600 500

Fan Static Pressure (Pa)

400 300 200 100 0 2.50

3.50

4.50

5.50

6.50

Air volume flow rate

7.50

8.50

9.50

10.50

(m3/s

nuaire.co.uk

31


Student Accommodation - ‘Project specific solution’

ASTON UNIVERSITY STUDENT VILLAGE ACCOMMODATION

REQUIREMENT: Compact heat recovery unit. Each area comprising of 6 bedrooms/wet areas and a communal living/kitchen area. Restricted bulkhead space of less than 320mm.

SOLUTION: Bespoke, high efficiency, compact heat recovery unit with 100% bypass, quick to install and low maintenance.

32

029 2085 8200


Student Accommodation Projects

2. Nido Kings Cross, London

1. Nido Spitalfields, London Beds: 1204

Beds: 1045

Products: MEVDC

Products: MEVDC

Completed: 2008

Completed: 2009

©

Nido Student Living, www.Nidostudentliving.com

3. 12 Quays, Birkenhead Beds: 280

4. RO Student Accommodation Bath

©

Nido Student Living, www.Nidostudentliving.com

5. Varley Halls, Brighton University

6. Swansea University Student Accommodation

Products: XBOXER

Beds: 850

Beds: 260

Beds: 250

Completed: 2012

Products: XBOXER XB & AVTCP

Products: ESTCP, SQF

Products: AIRMOVER

Completion: 2014

Completed: 2012

Completion: 2014

7. Aston Student Village, Birmingham

8. The Sanctuary, Bagot St. Birmingham

9. Frobisher House, Plymouth

10. Lancaster Bowland, Lancaster

Beds: 2400

Beds: 656

Beds: 133

Beds: 136

Products: XBOXER XB / Midi /

Products: MRXBOX95 /

Products: Airevolve AVT,

Products: Aire-Volve AVT / XS

Opusxbox

XBOXER XB / EST

XBOXER XBC.

Completed: 2013

Completed: 2013

Completed: 2011

Completed 2013/14

nuaire.co.uk

33


Care Home Accommodation Projects

1. Mersey Care, Liverpool

2. Louden Square, Cardiff

Beds: 85

Beds: 48 Flats

Products: MRXBOX95 / XBOXER XB

Products: MRXBOX95 / XBOXER CP

Completed 2013

Ongoing: 2013

3. Hengist Field Care Home, Kent

4. Crymych Care Home, Pembrokeshire

Beds: 75

Beds: 40

Products: XS / Opus / ESXCP /

Products: MRXBOX95 / XBOXER XB

XBOXER

Completed: 2013 / 14

Completed 2010

5. Bardowie Care Home, Glasgow

6. Caroline Lodge Care Home, Portsmouth

7. Charters Retirement Village, Sussex

8. Golau Caredig, South Wales

Beds: 120

Beds: 43

Beds: 140

Beds: 42

Products: XBOXER CP, AVT-CP, Opus

Products: Opus / XS / Genie

Products BOXER AHU, EST

Products: MRXBOX95 / SQF /

Completed: 2013

Completed: 2013

Completed 2013

XBOXER XB Completion: 2014

34

029 2085 8200


Hotel Accommodation Projects

1. St Pancras Chambers, London

2. Great Northern Hotel, London

3. St Davids Hotel, Cardiff

Beds: 244

Beds: 91

Beds: 142

Products: Ecosmart Xtractor, Ecosmart

Products: SQF, Ecosmart Quietscroll

Products: Ecosmart Quietscroll Twin Fans

Quietscroll Twin Fans, Airmover.

Twin Fans, Ecosmart Boxer

4. Hoxton, London

5. Hilton, Cardiff

6. Holiday Inn, Birmingham Airport

Beds: 205

Beds: 197

Products: Squrbo, XBOXER XB,

Products: Products: Ecosmart

Beds: 141

Ecosmart Boxer

Quietscroll Twin Fans

Products: XBOXER Thermal Wheel

7. Celtic Manor, Newport

8. Missoni, Edinburgh

Beds: 334.

Beds: 136

Products: Ecosmart Quietscroll

Products: Opus, Ecosmart Quietscroll

Twin Fans, Ecosmart Xtractor

Twin Fans

nuaire.co.uk

35


FOR MORE INFORMATION www.nuaire.co.uk COMMERCIAL www.nuaire.co.uk/commercial AIR HANDLING UNITS www.nuaire.co.uk/boxerahu BIM www.nuaire.co.uk/bim

NUAIRE LIMITED Western Industrial Estate | Caerphilly | CF83 1NA t +44 (0)29 2085 8200 | f +44 (0)29 2085 8300 | e info@nuaire.co.uk www.nuaire.co.uk

As part of our policy of continuous product development Nuaire reserves the right to alter specifications without prior notice. Telephone calls may be recorded for quality and training purposes.

Part Number 671644 Revised March 2014.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.