Structural Audit In Pune- Construction Diagnostic Centre

Page 1

Construction Diagnostic Centre We Qualify Structures

Pune, Maharashtra


About Us 

We are a consultancy & a construction material testing laboratory offering Non Destructive/ Material Testing (NDT), Quality Control, & Repair / Rehabilitation Consultancy services.

An offshoot of a parent company viz ‘Ranade Consultants’, a firm established in 1960, CDC draws on its vast and rich experience in Structural / RCC / Project Management & Architectural consultancy.

We are the ONLY firm offering all civil engineering-related Consultancy & Testing services under one roof.

We enjoys an Accreditation from NABL (ISO – 17025) for Non Destructive Testing and Mechanical Testing of Building Materials.


Services Offered 

Our Head Office is located in the heart of Pune city, with a Branch Office in Surat, Gujrat.

We believes in continuous improvement through on-going research and practice.

we provides services for the evaluation and condition assessment of existing structures, including application of non-destructive, in-situ, and load-testing methods for measuring existing states of stress, material properties, structural behaviour characteristics and material uniformity.


Projects Completed

Airports, Dams, Tunnels, Bridges, Concrete Roads, Jetties, Wind Mills, Earthquake / Blast / Fire-damaged Structures, Commercial / Mass Housing Projects, Educational Complexes, Cement ,Soya bean, Chemical Sugar, Thermal Power- Plants, Elevated Water Tanks, Reservoirs, Bunkers, Silos, Effluent / Water Treatment Plants and so on; in India as well as abroad.


Our Services

Non Destructive Testing

Construction Material

Repair & Rehabilitation

Heritage Structures

Failure Investigation

CIDC-Approved Retrofitting

Corporate Training

Concrete Quality Control

Structural Audit And Structural Stability Certification


Load Test 

IS – 456 – 2000 recommends Load testing of flexural members to be carried out In case the core test results do not satisfy the requirements.

Many a times Load test is carried out on building & Bridge components when –

The strength of concrete is below the acceptable norms

Structural Design data is not available.

Load carrying capacity of the flexural member needs to be assessed.

The members is to be subjected to a higher loads


Moisture Measurement 

Moisture is known to be one of the main sources causing deterioration of masonry and timber structures.

To identify the source of leakages and dampness moisture meters are very helpful.

If the concrete, masonry, timber structures are found to be wet, then appropriate repairs can be carried out to avoid further decay deterioration of the material and structure as a whole.


Ultrasonic Pulse Velocity Test 

Construction Diagnostic Centre has a very wide range of UPV machines with different frequency & different sizes probes, capable of scanning concrete up to 10 m wide.

This is one of the most commonly used methods, in which the ultrasonic pulses are transmitted through the concrete.

In solids, the particles can oscillate along the direction of sound propagation as longitudinal waves, or the oscillations can be perpendicular to the direction of sound waves as transverse waves.


Half Cell Potentiometer And Resistivity Meter 

The instrument measures the potential and the electrical resistance between the reinforcement and the surface to evaluate the corrosion activity as well as the actual condition of the cover layer during testing.



The electrical activity of the steel reinforcement and the concrete leads them to be considered as one half of weak battery cell with the steel acting as one electrode and the concrete as the electrolyte.



The name half-cell surveying derives from the fact that the one half of the battery cell is be the steel reinforcing bar and the surrounding concrete.


Bore Scope Survey / Endoscopy 

Endoscopy surveys provide a fast, cost effective means of identifying problematic / in-accessible areas where bear minimum destruction is allowed for inspection such as –

Concrete pipes,

Water Pipes

Storm pipes

Sewer Lines

Culvert

Cavity walls

Air ducts, Vents

Ceiling, roof and floor voids

Water tanks

Concrete or Masonry structures with large voids, honeycombing etc..


Underwater Investigation We carry out underwater inspection of structures like 

Dams

Bridges

Water Tanks

Effluent & Water Treatment Plants

Jetty

Underwater Structures Underwater camera Underwater Structures Corrosion of Underwater Structures captured by Camera Inspection of Jetty & Bridge Foundations by Underwater Camera


Non Destructive Testing 

Construction Diagnostic Centre has a full range of NDT instruments and conduct tests such as

Rebound Hammer Test – To assess the quality and strength of site concrete

Ultrasonic Pulse Velocity Test - To assess the quality and strength of site concrete

Concrete Core Extraction – To assess the In-situ strength of concrete, Making holes in RCC for Plumbing / Electrical purpose

Rebar Location & Cover-meter – Locating Reinforcement in the concrete

Half-cell potential Test & Resistivity Test - for Corrosion Mapping of reinforcement

Pile Integrity Test – For assessing the Integrity, Continuity & Depth of pile


Rebound Hammer Test 

This is the most common method adopted for checking strength of concrete since 1940.

The test is based on the principle that the rebound of an elastic mass depends on the hardness of the surface against which mass strikes.

The plunger of hammer is pressed strongly and steadily against the concrete surface at right angles to its surface, until the spring loaded mass is triggered from the locked position.

The distance traveled by the mass as a percentage is defined as rebound number.


Core Test And Core Cutting

This is one of the very reliable tests adopted for checking the compressive strength of the ‘In situ concrete”.

Other physical properties such as density, water absorption can also be measured from the core concrete.

In addition chemical properties of concrete specimen for its cement content, carbonation depth, chloride and sulphate content may be measured.


Rebar Locator And Bar Size 

The reinforcement bar is detected by magnetising it and inducing a circulating “eddy current” in it.

After the end of the pulse, the eddy current dies away, creating a weaker magnetic field as an echo of the initial pulse.

The strength of the induced field is measured by a search head as it dies away and this signal is processed to give the depth measurement.

The eddy current echo is determined by the depth of the bar, the size of bar and the orientation of the bar.

This detection of location of reinforcement is required as a pre process for core cutting.


Pile Integrity Test (Pulse Echo Method) 

It has been established that cast in situ piles in majority of the cases fail because of defective pile shaft necking, discontinuity of concrete, intrusion of foreign matter and improper toe formation due to contamination of concrete at base with soil particles,

washing of concrete due to high water current, adoption of improper construction method, poor quality control on concreting etc.

Cracks developed while handling of precast piles can also be a cause of failure.

If pile integrity can be assessed before completion of pile caps, then this will go a long way towards certification of pile integrity


Vibration Measurement 

Structural vibration in buildings can be detected by the occupants and can affect them in many ways:

Their quality of life can be reduced as also can their working efficiency.

Ground borne vibration from sources such as blasting, piling, machinery or road/rail traffic can be a source of concern for occupants of buildings in the vicinity.

This concern can lead to a need to assess the effect of the imposed vibration on the building structure to ascertain whether damage could occur.

It is increasingly recognized that buildings must sustain vibrations, and recognition of this is needed

both in design for structural integrity, serviceability and environmental acceptability, and in the preservation of historic buildings.

Measurement of vibration in a building is carried out for a variety of purposes:


Ultrasonic Thickness Gauge 

Using the Ultrasonic thickness Gauge we can find out the precise thickness of all such steel metal structures, components.

Ultrasonic Thickness Gauge a very useful tool in the structural audit / survey.

In most of the Industries, especially in Chemical factories corrosion is a very serious issue for the structural stability of the steel structures, M S Chimney, Stacks, Gantry girders, Pipe racks, Pipelines etc.

Using the Ultrasonic thickness Gauge we can find out the precise thickness of all such steel metal structures, components.


Infrared Thermometers



Used in combination with Moisture meters to identify the temperature gradient and spot temperatures from a long distance by just sighting the object.



a very useful tool in structural audits of the buildings, water structures, chimney etc.


Construction Material Laboratory Testing 

Construction Diagnostic Centre laboratory is well equipped to test for

Cement, Concrete, Steel, Aggregates, Bricks, Concrete blocks, Paving Blocks, Construction Chemicals, accelerated curing of concrete etc.

The lab offers state-of-the-art Mix Designs for Normal concrete, Pumpable concrete, High strength concrete, High early strength concrete, High performance concrete, Self-compacting concrete etc.

The Construction Diagnostic Centre lab has advanced and modern test set-up such as, fully computerized Universal Testing Machine and Compression Testing Machine, Concrete Pan Mixer, Temperature Controlled Curing Tanks along with all other test equipments.


Repair And Rehabilitation Consultancy 

In recent times, a large number of structures are observed to be in a distressed condition.

The structures may require repair / rehabilitation due to –

Poor quality concrete / workmanship

Construction Deficiencies

Design Deficiencies

Severe Exposure Condition

Corrosion

Aging

Damage due to Earthquake , Fire, Blast, Vibrations etc.

Settlement , Foundation problems.


Heritage Structures Conservation Consultancy 

At CDC we have the core expertise in assessment of the Heritage buildings. We have the most advanced Non Derstructive Testing tools , including consultancy services for structural conservation, strengthening & Retrofitting.

We offered such services to following Heritage Structures / Buildings –

1) Vishrambag wada – Built in 1800 - 1806 ( 205 years old ) – Ground + 2 Upper floor – Composite structure built in load bearing Brick / Stone masonry walls and Timber Column – Beam frame. The Wada was built by Bajirao II

2) Nana wada – ( 250 years old ) – Ground + 1 Upper floor – Composite structure built in load bearing Brick masonry walls and Timber Column – Beam frame. The Wada was built by Nana Phadnavis; who after the assassination of Peshwa Narayanrao in 1773 managed the affairs of state


Failure Investigation / Forensic Engineering Consultancy

At CDC we have a professionally trained staff having expertise in the failure investigation & Forensic Engineering.

We have carried out various failure investigations & Forensic Engineering for number of projects like –

RCC Silo Collapse

Full or Part Collapse of Buildings / Structures

Ground Water Reservoirs

Overhead Water Tanks

Conveyor Belt supporting steel structures

Fire Damaged Buildings


Concrete Quality Control And Audit 

We have developed a unique Quality Control & Auditing Scheme for RCC structures.

We offer a Total Quality Solution for concreting activity, which includes Testing of all building materials,

Monitoring concrete quality with NDT, Orientation Lecture for site engineers and tradesmen, quality control and audit of concreting activity.

CDC is known in construction industry for “No compromise on Quality”


Structural Audit And Structural Stability Certification

According to Government regulations,

All factories and residential societies are expected to undergo assessment and obtain a Structural Stability Certificate from a chartered civil engineer, every 5 years.

We are the competent authority to provide such certification.

We offer services including detailed inspection, assessing the strengths & weakness of the structure, conducting NDT, preparing repair / rehabilitation scheme, monitoring repair work and issuing Structural Stability Certificate.


CIDC Approved Retrofitting Clinic

Our laboratory is an approved “Retrofitting Clinic” of Construction Industry Development Council (CIDC – Established by Planning Commission – Government of India).


Corporate Training For Construction Industry 

“CDC” has drafted short lecture / workshops series for various Senior Engineers, Site engineers, Archiects and Supervisors working in construction industry


Contact Us Construction Diagnostic Centre 

Contact Person: Mr. Ravi Ranade

Mobile No: 9422007479

Phone:+91-20-25432643

Visit: http://structural-audits.com

Address:“Kanchan Bhavan”, 5, Shilavihar Colony.

City: Pune- 411038

State:Maharashtra (India)


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.