OZCO Project #212 IWPavilion Post and Beam – Free Standing
OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
1
1 19'9 4 "
1 16' 2 "
3 16'7 4 "
5 15'6 16 " = 1 15' 2 "
1 15'8 4 "
13 7'2 16 "
=
1 12'8 2 " 1 13'4 4 " 15'7"
Overview OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
3
Translucent OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
4
7
16
4
ITEM QTY. PART NUMBER NO. 1 4 51709 2 4 56620 10 51711 1 56625
17
3 15 19
2
56629
4
56621
7 8 9
1 2 4 1 8 16 2 4 4 4
10
4
11
32
12
22
13
2
14
8
15
6
16
4
17
1
18
2
19
2
51718 56615 51711 56625 56613 51711 56625 56651 8x8 Cedar Post 1x2 Cedar Board 1x4 Cedar Board 2x4 Cedar Board 2x6 Cedar Board 2x8 Cedar Board 2x8 Cedar Board 4x6 Cedar Board 4x6 Cedar Board 4x8 Cedar Board 4x10 Cedar Board 4x10 Cedar Board
4 5 6
12
18
3
14
9
11
13
10
1
8
2
Bill of Material
DESCRIPTION 8x8 Post Base (8x8-PB-IW) Truss Base Fan 10:12 Truss Accent (TA-IW) OWT Timber Screw 1-3/4" Screw, OWT 7-1/2" (190mm) Timber with HCN 1" Hex Cap Nut (HCN-1) 4" Standard Rafter Clips (RC-IW-4) Flush Inside 90 (FI-90) Truss Accent (TA-IW) OWT Timber Screw 1-3/4" Butt Joint Flush (BJF) Truss Accent (TA-IW) OWT Timber Screw 1-3/4" OWT Timber Bolt 8-10" 8x8x8'0" 1x2x16'0" 1x4x16'0" 2x4x10 3/4" 2x6x16'0" 2x8x16'0" 2x8x4'0" 4x6x8'0" 4x6x16'0" 4x8x16'0" 4x10x16'0" 4x10x16'0"
(shown without roof for clarity) OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/2/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/2/2017 . Please visit OZCOBP.com to get current information.
3
4 4 16 3 2 4 1 2 4 4
PART NUMBER 51709 56620 51711 56625 56629 56621 51718 56615 56613 56651
8x8 Post Base (8x8-PB-IW) Truss Base Fan 10:12 Truss Accent (TA-IW) OWT Timber Screw 1-3/4" Screw, OWT 7-1/2" (190mm) Timber with HCN 1 1/2" Hex Cap Nut (HCN) 4" Standard Rafter Clip (RC-IW-4) Flush Inside 90 Butt Joint Flush (BJF) OWT Timber Bolt 8-10"
4 4 4 4 22 2 4 6 4 1 4
8x8x8L 1x2x16L 1x4x16L 2x4x8L 2x6x16L 2x8x16L 2x8x8L 4x6x8L 4x6x16L 4x8x16L 4x10x16L
8x8x8 1x2x16 1x4x16 2x4x8 2x6x16 2x8x16 2x8x8 4x6x8 4x6x16 4x8x16 4x10x16
QTY.
DESCRIPTION
Material List OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/13/2018 . This information is updated periodically and should not be relied upon after 2 years from 3/13/2018 . Please visit OZCOBP.com to get current information.
3
56625
56613
51711
51718
56629
56615
51709
56620
56651
56621
OZCO OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
4
Suggested Tools (others may be required) OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
5
5 1'8 8 " 1 R3'1 2 "
2X8
45°
5 16 "
5 1 8 "x1.5 post width 7 18"
2X4
8X8
8'0"
7 98"
2"
2"
Cutlist1 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
6
16'0"
1 4x 2 " X 45°
1 4x 2 " X 45°
4x10
1 4'11 2 "
40°
4x6 Web 50°
3 4'8 8 "
4x6 King Post
3 54"
50°
50° 6'7"
Cutlist2 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
7
5 12'8 16 " 1x2
50°
50° 5 12'8 16 " 5 12'8 16 " 7 8"
50°
1x4 50° 5 12'7 8 "
1 12'6 16 " 1 12'6 16 " 4x6 & 2x6
50° 50° 3 1'10 16 "
40°
50° 15 2'1 16 "
Cutlist3 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
8
1 15'8 8 " Gable end of structure
1 20'7 16 "
1 20'7 16 " Locate desired center of structure
1 13'4 8 "
Gable end of structure
if site is not level, see Ozco Site Leveling instruction site OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
9
note post orientation
(Hex Cap Nut) provided Tool Required 3/8" Driver
(OWT Screw) provided
step 1 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
12
=
=
step 2 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
(Hex Cap Nut) provided Tool Required 3/8" Driver
(OWT Screw) provided V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
13
(Hex Cap Nut) provided Tool Required 3/8" Driver
(OWT Screw) provided
step 3 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
14
(Hex Cap Nut) provided Tool Required 3/8" Driver
step 4
(OWT Screw) provided
OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
15
secure with nails or screws
repeat on all posts
step 5 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
16
repeat connectors on backside of Truss CL
(Hex Cap Nut) provided Tool Required 3/8" Driver
CL
(OWT Screw) provided
step 6 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
17
repeat step 6 on opposite end
step 7 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
18
=
=
(Hex Cap Nut) provided Tool Required 3/8" Driver
step 8
(OWT Screw) provided
OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
19
secure with nails or screws
1'4" typ CL
~1-1/2" (Hex Cap Nut) provided Tool Required 3/8" Driver
(OWT Screw) provided
step 9 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
20
repeat previous step on opposite side
step 10 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
21
7 58"
secure with nails or screws repeat on opposite side
~1-1/2 (Hex Cap Nut) provided Tool Required 3/8" Driver
step 11 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
(OWT Screw) provided V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
22
1x2
1x4
secure with nails or screws repeat on all sides
step 12 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
23
1x2 1x4
3 14"
=
=
trim rafters as desired note: 1x2 & 1x4 to extend past rafters
step 13 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
24
secure with nails or screws repeat on opposite side
step 14 OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
25
shown with plywood and shingle roofing option
Roofing Option OZCO Project #212 IW- Pavilion Post and Beam – Free Standing
V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/1/2017 . This information is updated periodically and should not be relied upon after 2 years from 3/1/2017 . Please visit OZCOBP.com to get current information.
26
Ian's Concept 2x Stagger
2x Sandwich
4x
4x Beam Installation • 3 style choices • When 4x lumber not available or cost effective • see subsequent pages for details on each style see product installation instructions for hardware installation Ian's Concept
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/14/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/14/2017 . Please visit OZCOBP.com to get current information.
1
polyurethane adhesive, clamp & nail no post cuts
3" nail as desired
2x Stagger Ian's Concept
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/14/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/14/2017 . Please visit OZCOBP.com to get current information.
2
polyurethane adhesive, clamp & nail
nail as desired X Y
dato cut (2 sides)
Y
X - 1.75�
2x Sandwich Ian's Concept
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/14/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/14/2017 . Please visit OZCOBP.com to get current information.
3
X Y
dato cut (2 sides)
Y
X – 1.75�
4x Ian's Concept
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/14/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/14/2017 . Please visit OZCOBP.com to get current information.
4
multiple cuts approximately 1/4" apart to mark
mark ledge location
Y
pencil
remove pieces
set saw cut depth; start cuts 1/4" from top
Dato cut details Ian's Concept
V2.00 - Installation Instructions, Specifications and Project Plans are effective 6/14/2017 . This information is updated periodically and should not be relied upon after 2 years from 6/14/2017 . Please visit OZCOBP.com to get current information.
5